Anti Condensation Heaters Thermal Management Products & Accessories from SAN successfully used worldwide

Problem: Condensation forms due to fluctuating temperature, even in sealed enclo- sures. In combination with dust and aggressive gases condensation causes corrosion which results in stray currents and arcing. Too high a temperature, or for that fact too low a temperature, can also lead to serious component failure. The safety risk is enormous and the cost of operational delays as a consequence is incalculable. for control panels and enclo- sures Solution: Only constant optimum climatic conditions allow components to function properly. The right climate can be attained by a temperature and moisture control system. When tempera- tures are too low or when temperature differences (e.g. night / day) are large, heating is required. It may also be necessary to keep components cool by controlled ventilation. for traffic control and monito- ring systems in the transport Applications: industry Whether for telecommunications or traffic systems, power stations or outdoor plants, ATMs or parking control system, where electronics have to be protected against , heat or cold, SAN’s comprehensive product range offers effective economical solutions.

Our Products: Conventional and PTC semi-conductor control panel heaters and -assist- ed heaters ranging from 5W to 1200W, as well as tropicalised and EX varia- for high voltage swichtgear in tions. Temperature and humidity controls ranging from 0°C to 60°C (30° to outdoor and indoor substa- 140°F) and 35% to 100% RH. tions A new filter fan series in EMC and standard versions with excellent performance and shielding characteristics. Panel lighting and accessories.

About us: We have been developing and producing innovative products for thermal management for more than twenty years. Our products are renowned for their reliability and long life, simplicity of use and high quality. Used and proven system protction in the auto- worldwide even under extreme conditions. motive industry

in transmitter stations of cel- lular phone networks

for motor control centres and control cabinets

2 3 Contents:

Heating: Small semiconductor heater RCE 016 Series...... 4 Small semiconductor Heater RC 016 Series...... 5 Small semiconductor Heater HGK 047 Series...... 6 Small semiconductor Heater CSK 060 Series...... 7 Finned extruded Heater SAN-FXE...... 8 Semiconductor Heater HG 140 Series...... 9 Compact HGL 046 Series...... 10 Hazardous area Heaer CREx 020 Series...... 11 Electrical Direct Heater SAN-LP...... 12 Electrical Space Heater SAN-LP AF Ex Heater...... 13 Electrical Smart Heater SAN-SMLP...... 14 Semiconductor Heater CS 060 Series...... 15 Semiconductor Heater CSF 060 Series...... 16 Small semiconductor Fan Heater CS 028 Series...... 17 Compact semiconductor Fan Heater CSL 028 Series...... 18 Electrical Smart Heater SAN-GSMLP...... 19 Explosion proof Heater SP...... 20 Electrical Smart Heater...... 21 Electrical Smart-Space Ex Heater SM-*A...... 22 Electrical Direct Ex Heater CS-*S...... 23 Electrical Direct Ex Heater CT-*A...... 24 Anti Condensation and Space Heater SAN-HEF...... 25 Space-saving Fan Heater HV 031 / HVL 031 Series...... 26 Semiconductor Fan Heater CR 027...... 27 Fan Heater with integrated or hygrostat CR 030...... 28 Fan Heater with integrated thermostat or hygrostat CR 130...... 29 Fan Heater with/without integrated thermostat CS 030...... 30 Fan Heater with/without integrated thermostat CS 130...... 31 Ventilating: Low maintenance Filter Fan FF 018 Series (21m3/to 102m3/h)...... 32-33 Low maintenance Filter Fan FF 018 Series (200m3/h)...... 34 High-performance Filter Fan FF 018 Series (300m3/h)...... 35 High-performance Filter Fan FF 018 Series (550m3/h)...... 36 Outdoor Filter Fan FF 018 Series...... 37 Low noise Roof Filter Fan RFF 018 Series...... 38 High-performance 19” Fan Tray LE 019 Series...... 39 Regulating and monitoring: Electronic Relay SM 010 (DC 24V + DC 48V)...... 40 Small, compact Thermostat KTO 011 / KTS 011...... 41 Fix Thermostat FTO 011 / FTS 011...... 42 Dual Thermostat ZR 011...... 43 Dual Thermostat FTD 011...... 44 Mechanical Thermostat FZK 011...... 45 Electronic Thermostat ET 011 (DC 24V)...... 46 Ex FixTherm96 Thermostat...... 47 FixTherm96 Thermostat...... 48 Mechanical Hygrostat MFR 012...... 49 Electronic Hygrostat EFR 012...... 50 Electronic Hygrottherm ETF 012...... 51 Hazardous area Thermostat REx 011 Series...... 52 Lighting: Slimline Lamp with on/off switch SL 025 Series...... 53 Slimline Lamp with movement sensor SL 025 Series...... 54 Dual Lamp with on/off switch DL 026 Series...... 55 Dual Lamp with movement sensor DL 026 Series...... 56 Hand Lamp with lamp holder DL 026 Series...... 57 Compact Lamp KL 025 Series...... 58 Accessories: Electrical Sockes SD 035 Series ...... 59 Pressure compensation Device DA 084...... 60 Pressure compensation Device DA 284...... 61 Pressure compensation Device DA 284 (stainless steel)...... 62 Self-adhesive appliance holder SANOFIX...... 63

Calculation of temperature control in encloseures...... 64

Indication of measurements in m.m. Errors and omissions excepted. Specifications are subject to change with- out notice. Suitability of the products for their intended use and any associated risks must be determined by the end customer/buyer in their final application.

2 3 5W, 9W Small semiconductor Heater - RCE 016 Series

• Temperature limiting • Wide voltage range • Dynamic heating up • Energy saving • Compact

Small heaters designed to prevent condensation and to ensure a minimum operating temperature in small enclosures.

Technical Data: Operating voltage 12-240V AC/DC* (min. 110V, max. 265V) PTC resistor, temperature limiting Heater body Aluminum Mounting See Accessories Fitting position Variable Dimensions Length 45mm, Ø10mm Op./storage temperature -45 to +70ºC Prot. type / Prot. class IP32 / II (double insulated) Approvals VDE + UL File No. E150057 Accessories Mounting clips (see illlustration) Note Other voltages on request *) Op. with voltages below AC/DC 140V reduces heating performance by approx. 10%.

Example of connection

Thermostat KTO 011 Heater RCE 016 (contact breaker, normally closed)

Connection 2xAWG 22 sheathed cable (silicone) L N

Mounting clips Art. No. (1 packing unit = 2 pieces)

Art. No. Voltage Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.) 82240 120-240 5W 2.0A 165˚C 2xAWG 22 sheathed cable (silicone) 20g 82241 12-36 5W 82242 120-240 9W 2.5A 175˚C 2xAWG 22 sheathed cable (silicone) 20g 82243 12-36 10W * At 20ºC (68˚F) ambient temperature.

4 5 8W, 10W, 13W Small semiconductor Heater - RC 016 Series

• Temperature limiting • Wide voltage range • Dynamic heating up • Energy saving • Compact

These small heaters are designed to prevent condensation and to ensure a minimum operating temperature in small enclosures.

Technical Data: Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V) Heating element PTC resistor, temperature limiting Heater body Aluminium, anodised Mounting Screw fixing Fitting position Variable Op./storage temperature -45 to +70ºC (-40 to +158˚F) Prot. type / Prot. class IP32 / II (double insulated) Approvals VDE + UL File No. E150057 Note Other voltages on request Art. No. : Connection 2xAWG 18 stranded wire *Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Example of connection

Thermostat KTO 011 Heater RC 016 (contact breaker, normally closed) Art. No. : Connection 2xAWG 22 sheathed cable (silicone)

Art. No. : Connection 2xAWG 22 sheathed cable (silicone) L N

Art. No. Heating capacity* Inrush current max. Surface temp. (approx.) Connection Weight (approx.) 82244 8W 2.0A 150˚C 2xAWG 18 stranded wire 20g 82246 10W 2.5A 155˚C 2xAWG 22 sheathed cable (silicone) 28g 82248 13W 3.0A 170˚C 2xAWG 22 sheathed cable (silicone) 34g 82243 8W 3.7A 134˚C 2xAWG 18 stranded wire 20g 82247 10W 5.7A 132˚C 2xAWG 22 sheathed cable (silicone) 28g 82249 13W 10.0A 148˚C 2xAWG 22 sheathed cable (silicone) 34g * At 20ºC (68˚F) ambient temperature.

4 5 10W to 30W Small semiconductor Heater - HGK 047 Series

• Dynamic heating up • Energy saving • Wide voltage range • Temperature limiting • Clip fixing

The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured.

Technical Data: Heating element PTC resistor, temperature limiting Heater body Extruded aluminium profile, anodised Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op. / Storage temp. -45 to +70ºC Prot. type / Prot. class IP54 / I (earthed) Accessories Screw fixing

50 25

Clip for 35mm DIN rail

L

Example of connection

Thermostat KTO 011 Heater HGK 047 (contact breaker, normally closed)

12

300

L N

Art. No. Operating voltage Heating Inrush Length Weight Connection Approval capacity1) current max. (L) (approx.) 83250 120-240V AC/DC2) 10W 1.0A 50mm 0.1kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE 83251 120-240V AC/DC2) 20W 2.5A 60mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE 83252 120-240V AC/DC2) 30W 3.0A 70mm 0.2kg 3 x 0.5mm2 x 300mm sheathed cable (silicone) VDE 83253 110-120V AC/DC 10W 1.0A 50mm 0.1kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 83254 110-120V AC/DC 20W 1.5A 70mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 83255 110-120V AC/DC 30W 1.5A 100mm 0.2kg 3 x AWG 20 x 300mm sheathed cable UL File No. E150057 1) at 20°C ambient temperature; 2) (min. 110V, max 265V) Operating with voltages below 140V AC/DC reduces heating performance by approx. 10%.

6 7 10W, 20W Touch-Safe Small Semiconductor Heater - CSK 060 Series

• Low surface temperature • Double insulated (plastic housing) • Wide voltage range • Temperature limiting • Dynamic heating up • Clip fixing

The heaters are used in enclosures where condensation is to be prevented or the temperature may not fall below a minimum value. In this way corrosion is avoided and an even temperature is ensured. The heaters are designed for permanent operation.

Technical Data: Operating voltage 120-24V AC/DC* -(min. 110V, max. 265V) Heating element PTC resistor, temperature limiting Surface temperature <85ºC (according to VDE 0100) except upper protective Connection 2-pole terminal 2.5mm2, torque 0.8Nm max. Casing Plastic according to UL94 V-0, black Dimensions 98 x 38 x 75mm Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op./storage temp. -45ºC to +70ºC Prot. type / Prot. class IP20 / II (couble insulated) Approvals VDE + UL File No. E150057 (according to UL499 in combination with UL508A) Note Other voltages on request *Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Example of connection

Thermostat FTO 011 Heater CSK 060 (contact breaker, normally closed)

Art. No. Heating capacity* Inrush current max. Weight (approx.) 10W 1.0A 0.2kg 20W 2.5A 0.3kg * At 20ºC (68˚F) ambient temperature.

6 7 Finned Extruded Enclosure Heater Type SAN-FXE

The FXE range of heaters is designed specifically for frost protection, an- ti-condensation and temperature control within Zone 1 and Zone 2 Ha- zardous Areas. The FXE delivers a constant power output and comes com- plete with mounting bracket and a 1.5 metre flying lead.

Features • Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx. • Compact design, requires minimal space. • Optional over-temperature protection. • Black anodized convective surface. • Standard product available with short delivery times. • Suitable for ambient temperatures -50°C up to +80°C.

Typical Applications: Control / monitoring panels Instrumentation cabinets Condensation prevention Temperature fluctuations Frost protection Motor enclosures

Certification IECEx & ATEX certified Ex II 2 G/D, Ex d IIC (Gas) T3-T4 Gb, Ex t IIIC (Dust) T200-T135°C Db, EN/IEC60079-0 & EN/ IEC60079-1 & EN/IEC 60079-31

Extrusion Finned Aluminium, Anodized Matt Black

Mounting: Vertically Mounted by Bracket or Rail

Voltage: Up to 254VAC

Rating: Available in 30, 50, 75 & 100 Watts

Controls If required, heaters can be supplied with a range of remote mounted .

Element: 18mm dia 321 St/Steel cartridge element with 1.5m silicone flex cable.

Weather protection: IP6X

8 9 15W to 150W Semiconductor Heater - HG 140 Series

• Pressure clamp connectors • Dynamic heating up • Wide voltage range • Temperature limiting • Energy saving • Clip fixing • Quick installation

These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value. The aluminium profile heater body design has a chimney effect and distributes the heat evenly. The pressure clamp connectors save time and simplify installation.

Technical Data: Operating voltage 120-240V AC/DC* (min. 110V, max. 265V) Heating element PTC resistor, temperature limiting Heater body Extruded aluminium profile, anodised Connection 3 pressure clamps for stranded wire 0.5-1.5mm² (with wire end ferrule) and rigid wire 0.5-2.5mm2 Connection casing Plastic according to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op./storage temperature -45 to +70ºC Prot. type / Prot. class IP20 / I (earthed) Approvals VDE + UL file E150057 Accessories Screw fixing *Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Art. No. Heating capacity* Inrush current max. Length (L) Weight (approx.) 83190 15W 1.5A 65mm 0.3kg 83191 30W 3.0A 65mm 0.3kg 83192 45W 3.5A 65mm 0.3kg 83193 60W 2.5A 140mm 0.4kg 83194 75W 4.0A 140mm 0.5kg 83195 100W 4.5A 140mm 0.5kg 83196 150W 9.0A 220mm 0.7kg *At 20ºC (68˚F) ambient temperature.

8 9 Compact Fan Heater - HGL 046 Series

• Compact design • Temperature safety cut-out • Clip fixing • Long service life • Maintenance free

This compact fan heater prevents the formation of conden- sation. The integrated axial fan provides forced air circula- tion and so guarantees an even temperature in enclosures. A built-in temperature safety cut-out switches the heater off, in the event of fan failure.

Technical Data: Operating voltage AC 220-240V, 50-60Hz AC 110-120V, 50-60Hz Other voltages on request (e.g. AC/DC 48V) Heating element Resistance heater Temp. safety cut-out To protect against overheating in case of fan failure. Heater body Extruded aluminium profile, anodised Surface temperature Max 75°C (400W) Axial fan Ball bearing service life 50 000h at 25°C (77°F) airflow 35m³/h, free flow Connection 3-pole clamp for 2.5mm² Mounting Clip for 35mm DIN rail, EN 50022 Fitting position Preferably vertical Op./storage temperature -40 to +70ºC (-40 to +158˚F) Prot. type / Prot. class IP20/I (earthed) Approvals VDE, UL file E150057

Art. No. Approval Operating voltage Heating capacity* Length (L) Weight (approx.) 83256 VDE AC 230V, 50-60Hz 250W 170mm 1.0kg 83257 VDE AC 230V, 50-60Hz 400W 252mm 1.3kg UL AC 115V, 50-60Hz 250W 170mm 1.0kg 83257-1 UL AC 115V, 50-60Hz 400W 252mm 1.3kg UL AC 230V, 50-60Hz 250W 170mm 1.0kg UL AC 230V, 50-60Hz 400W 252mm 1.3kg *At 20ºC (68˚F) ambient temperature.

10 11 50W, 100W Hazardous area Heater - CREx 020 Series

• Large surface • Clip fixing • Ready for use • Maintenance free

Compact for use in areas with explosion hazard for prevention of formation of condensation, temperature fluctuations and for protection against frost in transmitter housings, switch cabinets and measur- ing equipment.

Technical Data: Explosion protection acc. to EN LCIE (Laboratoire Central des Industries Electriques) Conformity certificate 01 ATEX 6073/03, LCIE No 06 ATEX Q8011, IECEx LCI 07, 0020 Heating element High performance cartridge Heater body Aluminium profile, black anodised Connection Si HF-JZ 3 x 0.75mm2 cable, length 1m Connection PE 4mm2 Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Operating/storage temperature -20 to +40ºC / -45 to 70ºC Protection type /Protection class IP65 / I (earthed)

Clip can alternatively be fixed on long side

Hazardous area Thermostat REx 011 see page 40

Art. No. Operating voltage Heating capacity* Ex protection type Surface temperature Length (L) Weight (approx.) 83197 230-240VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg 83198 230-240VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg 110-120VAC 50W d IIC T5 - Ex tD A21 IP6X T100˚C 100˚C 150mm 1.3kg 110-120VAC 100W d IIC T4 - Ex tD A21 IP6X T135˚C 135˚C 180mm 1.5kg

10 11 Electrical Direct Heater SAN-LP Heater

Direct-heaters for Hazardous locations, designed for direct mounting onto e.g. manifolds etc. • Freeze protection • Anti-condensation • Temperature maintenance

Features and Advantages

• Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx. • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required therefore long lifetime • Suitable for T4 and T3 classifications • Can be used for 110 / 240 VAC/DC

Description

All Cameo Heaters are designed around self-limiting heating elements. These self-limiting semi-conductor elements are saving power consumption. Our Cameo Direct-heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

Optional body #5 : 4 holes diam. 5,2 mm. available in Aluminium and SS range For easy mounting, at no extra charge

Alternative 316 Stainless Steel heaters can be delivered for the 100-10 Watt range. Also possible is an aluminium body with four holes drilled through (body #5), for easy mounting. Please see below for further technical data.

Range

LP-1A T3 ca. 115 °C Surface temperature 100-10 Watt LP-2A T4 ca. 105 °C Surface temperature 100-10 Watt LP-3A T4 ca. 90 °C Surface temperature 100-10 Watt LP-4A T4 ca. 70 °C Surface temperature 100-10 Watt

High Power model:

LP- 0AHP T3 ca. 130 °C Surface temperature 200-20 Watt

* these temperatures are measured at 20 °C ambient temperature.

12 13 Electrical Space Heater SAN-LP AF Ex Heater

Space-heaters for Hazardous locations, designed for : • Freeze protection • Anti-condensation • Temperature maintenance

Technical Data: Power consumption 100-10 Watt Electrical cable 3x1 sqmm Material cable braided silicone, optional: non-braided cable Standard length approx. 1 mtr. Other lengths optional Other lengths To be specified Overall dimensions 164x100x60mm (LxWxH) Material black anodized aluminium EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C Certification KEMA 01ATEX2124X and IECEx DEK 11.0017 Protection degree IP66 Voltage 110/240 Ambient temp. range -60°C...+90°C

Features and Advantages Range LP-1AF T3 ca. 115 °C Surface temperature 100-10 Watt • Self-limiting heating elements LP-2AF T4 ca. 105 °C Surface temperature 100-10 Watt • Small dimensions LP-3AF T4 ca. 90 °C Surface temperature 100-10 Watt • No moving parts, no maintenance required therefore LP-4AF T4 ca. 70 °C Surface temperature 100-10 Watt long lifetime • Suitable for T4 and T3 classifications * these temperatures are measured at 20 °C ambient tempe- • Can be used for 110 / 240 VAC/DC rature.

Description

All Cameo Heaters are designed around self-limiting hea- ting elements. These semi-conductor elements are saving power consumption. Our Cameo Space-heaters heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

In other situations, if the equipment, e.g. analyzers, it is nor- mal practice to use our Space-Heters in combination with our Fix-Therm96 thermostats (range from 10°C up to 135°C)

Do not cover the fins to guarantee free convection.

12 13 Electrical Smart Heater for Space Heating SAN-SMLP Ex Heater

Space-heaters for Hazardous locations, this compact model is designed for • Anticondensation • Freeze protection • Temperature maintenance • Small spaces

Features and Advantages • Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx. • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required therefore long lifetime • Suitable for T4 and T3 classifications • Can be used for 110 / 240 VAC/DC

Description

All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption.

Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system.

When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi- nation with our FixTherm96 thermostats (range from 10°C up to 135°C).

Do not cover the fins to guarantee free convection..

Range

SMLP-1A T3 ca. 115°C Surface temperature 100-10 Watt SMLP-2A T4 ca. 105°C Surface temperature 100-10 Watt SMLP-3A T4 ca. 90°C Surface temperature 100-10 Watt SMLP-4A T4 ca. 70°C Surface temperature 100-10 Watt

High power model: SMLP- 0AHP T3 ca. 130°C Surface temperature 200-20 Watt

* these temperatures are measured at 20 °C ambient temperature.

14 15 50W to 150W Touch-Safe Semiconductor Heater - CS 060 Series

• Low surface temperature • Quick mounting due to clip fixing • Double insulated (plastic) • Wide voltage range • Small size

Touch-safe heater for the use in enclosures with electrical/electronical com- ponents. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the ac- cessible side surfaces of the housing are kept down as a result of the heater design. Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060. This heater is also available in a version with plug-in thermostat requiring no additional wiring (C*SF 060). Both ver- sions are designed for permanent operation.

Technical Data: Operating voltage 120-240V AC/DC* (min. 110V, max. 265V) Heating element PTC resistor, temperature limiting Surface temperature <80ºC, except upper protective grille Connection 4-pole terminal 2,5mm2, torque 0.8Nm max. Casing Plastic according to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op./storage temperature -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated) Approvals VDE + UL file E150057 (according to UL499 in combination with UL508A) Note Other voltages on request *Op. with voltages below 140V AC/DC reduces heating performance by approx. 10%.

Heater CS 060 Heater CS 060

Thermostat FTO 011

HeatingLeistungs-Umgebungstemperatur-Diagram capacity / Ambient temperature diagramm CS 060 CS 160

200 AC 178

160 147

) 150 132

(W Heater CS 060 122 119 110 Art. Nr. 16000.0-00 102 100 93 85 Art. Nr. 16010.0-00 Thermostat 66 61 FTO 011 55

Heizleistung 50 Heating capacity (W) 50 44 Art. Nr. 16020.0-00

0 -40 -20 0 20 40

UmgebungstemperaturTemperature (ºC) (°C) AC

Examples of connection

Art. No. Heating capacity1) Inrush current max. Air outlet temp.2) Dimensions Weight (approx.) 50W 2.5A +86ºC 110 x 60 x 90mm 0.3kg 100W 4.5A +120ºC 110 x 60 x 90mm 0.3kg 150W 8A +145ºC 150 x 60 x 90mm 0.5kg 1)Ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille.

14 15 50 W to 150W Touch-Safe Semiconductor Heater - CSF 060 Series

• Low surface temperature • Integrated thermostat • Quick mounting due to clip fixing • Double insulated (plastic) • Wide voltage range • Small size

Touch-safe heater for the use in enclosures with electrica/electronical com- ponents. The design of the heater supports the natural convection which results in a high air-current of warm air. The surface temperatures on the ac- cessible side surfaces of the housing are kept down as a reslt of the heater design. This model with plug-in thermostat does not require additional wiring. The heaters are designed for the permanent operation. This heater is also available in a version without thermostat (CS 060).

Technical Data: Operating voltage 120-240VAC* (min. 110V, max. 265V)

Heating element PTC resistor, temperature limiting 60 Surface temperature <80ºC, except upper protective grille Connection 4-pole terminal 2.5mm2, torque 0.8Nm max. 90 Casing Plastic according to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op./storage temp. -20 to +70ºC / -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)

Approvals VDE + UL File No. E150057 (acc. to UL499 in combination with UL508A) L Note Other voltages on request *Op. with voltages below 140VAC reduces heating performance by approx. 10%

23

Leistungs-Umgebungstemperatur-Diagramm Heater CSF 060 Heating capacity / AmbientCS temperature160 diagram CSF 060 200 178

160 147

) 150 132

(W 122 119 110 Art. Nr. 16000.0-00 102 100 93 85 Art. Nr. 16010.0-00 66 61 55

Heizleistung 50 50 44 Art. Nr. 16020.0-00 Heating capacity (W)

0 Example of connection -40 -20 0 20 40 Umgebungstemperatur (°C) Temperature (ºC)

Art. No. Heating Inrush current Air outlet Switch-off Starting Dimensions Weight (approx.) capacity* max. temperature2) temperature3) temperature3) 50W 2.5A +86ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg 50W 2.5A +86ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg 100W 4.5A +120ºC +15ºC +5ºC 110 x 60 x 90mm 0.3kg 100W 4.5A +120ºC +25ºC +15ºC 110 x 60 x 90mm 0.3kg 150W 8A +145ºC +15ºC +5ºC 150 x 60 x 90mm 0.5kg 150W 8A +145ºC +25ºC +15ºC 150 x 60 x 90mm 0.5kg 1)ambient temperature - see Heating capacity / Ambient temperature diagram; 2)measured 50mm above protective grille; 3)tolerance of ±5K.

16 17 150W Small Semiconductor

Fan Heater 95 - CS 028 75

• Small, compact design

• Quite in operation 32 90 65 • Dynamic heating up • Clip or screw fixing

Fan heater prevents formation of condensation and provides an evenly dis- tributed interior air temperature in enclosures with electric/electronic compo- nents. The heater is connected using the internal terminal connectors. The CS 028’s small size make it ideal for use in enclosures where space is at a premium.

95 75

Technical Data: 75 32 90 65 Heating element PTC heating element Inrush current max. 12A at 230VAC, 6A at 120VAC Surface temperature max. 50ºC at casing; 100ºC at upper protective grille at 20ºC ambient temperature. 65 90 Axial fan, ball bearing Air flow 13.8m3/h, free flow (service life 40,000h at 40ºC) Connection 2-pole clamp max. 2.5mm2, clamping screw torque 0.8Nm max. Casing Plastic according to UL94-0, black Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm) Fitting position Vertical Weight Approx. 0.3kg Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated) Note Other voltages on request. View: back side

75 Heating capacity / Ambient temperature diagram CSF 060 Screw fixing

Clip fixing

30 20 40 65 90 10 50 0 60 3 4

95 75 Heating capacity (W)

L 32 Temperature (ºC) N Example of connection FAN Heater CS 028 Thermostat KTO 011 (contact breaker, normally closed)

30 20 40

10 50 0 60 3 4

95 75

L 32 N

Art. No. Operating voltage Heating capacity* Dimensions Mounting Approvals 230VAC, 50/60Hz 150W 87 x 65 x 75mm Clip fixing VDE; (UL submitted) 230VAC, 50/60Hz 150W 87 x 65 x 114mm Screw fixing VDE, (UL submitted) 120VAC, 50/60Hz 150W 87 x 65 x 75mm Clip fixing UL submitted 120VAC, 50/60Hz 150W 87 x 65 x 114mm Screw fixing UL submitted *at 20ºC ambient temperature.

16 17 250W, 400W Compact Semiconductor Fan Heater - CSL 028

• Small, compact design • Quiet in operation • Dynamic heating up • Clip or screw fixing

Fan heater prevents formation of condensation and provides an evenly dis- tributed interior air temperature in enclosures with electric/electronic compo- nents. The heater is connected using the internal terminal connectors. The small size of the CSL 028 makes it ideal for use in enclosures where space is at a premium.

Technical Data: Heating element PTC heating element Surface temperature 250W: max 50ºC, except upper protective grille 400W: max 65ºC, except upper protective grille at 20ºC ambient temperature Axial fan, ball bearing Air flow 45m3/h at 230VAC, air flow 54m3/h at 120VAC free flow, service life 40,000h at 40ºC Connection 2-pole clamp max. 2.5mm2 with strain relief, clamping torque 0.8Nm max. Casing Plastic acc. to UL94-0, black Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (Ø5.3mm) Fitting position Vertical Weight Approx. 0.5kg View: back side Op./storage temp. -45 to +70ºC Screw fixing Clip fixing Prot. type / Prot. class IP20 / II (double insulated) Note Other voltages on request

Heating capacity / Ambient temperature diagram CSF 060

Example of connection Thermostat KTO 011 FAN Heater CSL 028

Heating capacity (W) (contact breaker, normally closed)

Temperature (ºC)

Art. No. Operating voltage Heating capacity* Inrush current max. Dimensions Mounting Approvals 83710 230VAC, 50/60Hx 250W 9A 111x85x90mm Clip fixing VDE; (UL submitted) 83711 230VAC, 50/60Hz 250W 9A 111x85x129mm Screw fixing VDE; (UL submitted) 120VAC, 50/60Hz 250W 6A 111x85x90mm Clip fixing UL submitted 120VAC, 50/60Hz 250W 6A 111x85x129mm Screw fixing UL submitted 83715 230VAC, 50/60Hz 400W 15A 111x85x90mm Clip fixing VDE; (UL submitted) 83716 230VAC, 50/60Hz 400W 15A 111x85x129mm Screw fixing VDE; (UL submitted) 120VAC, 50/60Hz 400W 9A 111x85x90mm Clip fixing UL submitted 120VAC, 50/60Hz 400W 9A 111x85x129mm Screw fixing UL submitted *at 20ºC ambient temperature

18 19 Electrical Smart Space-Heater, General purpose SAN-GSMLP Heater

Space-heaters for Non-Hazardous locations are designed for • Anticondensation • Freeze protection • Temperature maintenance

Features and Advantages • Self-limiting heating elements • Small dimensions • No maintenance required, no moving parts: long lifetime • Can be used for 110 / 240 VAC/DC

Technical Data: Power consumption 200-20 Watt Electrical cable 3x1 sqmm Material cable non-braided silicone cable Standard length approx. 1 mtr. Other lengths optional Other lengths To be specified Overall dimensions 100x54x54mm (LxWxH) Weight Approx. 1400g Material black anodized aluminium Protection degree IP66 Voltage 110/240

Clip fixing High power model: GSMLP- 0AHP T3 ca. 130°C Surface temperature 200-20 Watt

* these temperatures are measured at 20 °C ambient temperature.

Description

All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are FAN Heater CSL 028 saving power consumption.

Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

In other situations, if the equipment may not exceed a maximum temperature value, you can add our Fix-Therm96 thermostat as a maximum temperature protection, in the system.

When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combi- nation with our FixTherm96 thermostats (range from 10°C up to 135°C).

Do not cover the fins to guarantee free convection..

18 19 Explosion proof Anti Condensation Heater - SP

Space-heaters for Hazardous locations are designed for • Freeze protection • Anti-condensation • Temperature maintenance

Features and Advantages • Self-limiting heating elements • Small dimensions • No maintenance required, no moving parts: long lifetime • Suitable for T4 and T3 classifications • Can be used for 110 / 240 VAC/DC Description

Technical Data: Power consumption 250-25Watt or 500-50Watt Electrical cable 3x1 sqmm Material cable Braided silicone (standard) non-braided optional Standard length approx. 1 mtr. Other lengths optional, on request Other lengths To be specified Overall dimensions 165x185x41,6mm (LxWxH) Weight Approx. 1600g Material black anodized aluminium EX protection class II2G Ex d IIC T4 or T3: II2D Ex tD A21 IP66 T135ºC or T200ºC Certification KEMA 01ATEX2124X and IECEx DEK 11.0017 Protection degree IP66 Voltage 110/240 VAC/DC Ambient temp. range -60ºC...+90ºC

All SP Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our SP Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. When required in other appications, e.g. analyzers, it is normal to use our space heaters in combination with our Fix-Therm96 termostats (range from 10°C up to 135°C).

Do not cover the fins to guarantee free convection.

Part No. Temp. class Surface temp. Wattage SP-1A T3 Approx 115ºC 250-25 SP-2A T4 Approx 105ºC 250-25 SP-3A T4 Approx. 90ºC 250-25 SP-4A T4 Approx. 70ºC 250-25 High power model SP-0AHP T3 Approx. 130ºC 500-50 *these temperatures are measured at 20ºC ambient temperature.

20 21 Electrical Smart-Space Heater Type GSM-*A

Space-heaters for Non-Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenance

Features and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there- fore long lifetime • Can be used for 110 / 240 VAC/DC

Technical Data: Power consumption 250-25Watt or 500-50Watt Electrical cable 3x1 sqmm Material cable Non-braided silicone cable Standard length approx. 1 mtr. Other lengths optional, on request Other lengths To be specified Overall dimensions 164x54x54mm (LxWxH) Weight Approx. 1400g Material black anodized aluminium Voltage AC/DC 110/240 Protection class IP66

Description All Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina- tions with our FixTherm96 (range from 10°C up to 130°C).

Part No. Surface temp. Wattage Smart GSM-1A Approx 115ºC 250-25 Smart GSM-2A Approx 105ºC 250-25 Smart GSM-3A Approx. 90ºC 250-25 Smart GSM-4A Approx. 70ºC 250-25 High power model Smart GSM-0AHP Approx. 130ºC 500-50 *these temperatures are measured at 20ºC ambient temperature.

20 21 Electrical Smart-Space Ex Heater Type SM-*A

Space-heaters for Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenance • Small spaces Features and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there- fore long lifetime • Suitable for T4 and T3 classification • Can be used for 110 to 240 VAC/DC

Technical Data: Power consumption 250-25Watt or 500-50Watt Electrical cable 3x1 sqmm Material cable Braided silicone (standard) Non-braided optional Standard length approx. 1 mtr. Other lengths optional, on request Other lengths To be specified Overall dimensions 164x54x54mm (LxWxH) Weight Approx. 400g Material black anodized aluminium EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C Certification KEMA 01ATEX2124X and IECEx DEK 11.0017 Voltage AC/DC 110/240 VAC/DC Protection degree IP66 Ambient temp. range -60°C...+90°C

Description All Smart Space-Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Smart Space-Heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed. In other situations, if the equipment may not exceed a maximum temperature value, our Fix-Therm96 thermostat can be added as a maximum temperature protection, in the system. When required in other applications, e.g. analyzers, it is normal practice to use our Smart Space-Heaters in combina- tions with our FixTherm96 (range from 10°C up to 135°C).

Part No. Surface temp. Wattage Smart SM-1A Approx 115ºC 250-25 Smart SM-2A Approx 105ºC 250-25 Smart SM-3A Approx. 90ºC 250-25 Smart SM-4A Approx. 70ºC 250-25 High power model Smart SM-0AHP Approx. 130ºC 500-50

*these temperatures are measured at 20°C ambient temperature.

22 23 Electrical Direct Ex Heater Type CS-*S

Space-heaters for Hazardous locations, designed for direct mounting onto e.g. manifolds etc. • Freeze protection • Anti-condensation • Temperature maintenance Features and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there- fore long lifetime • Suitable for T4 and T3 classification • Can be used for 110 to 240 VAC/DC

Technical Data: Power consumption 250-25Watt Electrical cable 3x1 sqmm Material cable Braided silicone; optional: Non-braided optional Standard length approx. 1 mtr. Other lengths optional Other lengths To be specified Overall dimensions 85x65x28mm (LxWxH) Weight Approx. 900g Material stainless steel 316 EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C Certification KEMA 01ATEX2124X and IECEx DEK 11.0017 Voltage AC/DC 110/240 VAC/DC Protection degree IP66 Ambient temp. range -60°C...+90°C

Description All Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

Part No. Classification Surface temp. Wattage CS-1S T3 Approx 115ºC 250-25 CS-2S T4 Approx 105ºC 250-25 CS-3S T4 Approx. 90ºC 250-25 CS-4S T4 Approx. 70ºC 250-25

*these temperatures are measured at 20°C ambient temperature.

22 23 Electrical Direct Ex Heater Type CT-*A

Direct heaters for Hazardous locations, designed for • Freeze protection • Anti-condensation • Temperature maintenance Features and Advantages • Self-limiting heating elements • Small dimensions • No moving parts, no maintenance required there- fore long lifetime • Suitable for T4 and T3 classification • Can be used for 110 to 240 VAC/DC

Technical Data: Power consumption 250-25Watt Electrical cable 3x1 sqmm Material cable Braided silicone; optional: Non-braided optional Standard length approx. 1 mtr. Other lengths optional Other lengths To be specified Overall dimensions 88x70x35mm (LxWxH) Weight Approx. 550g Material black anodized aluminium EX protection class II 2G Ex d IIC T4 or T3: II 2D Ex tD A21 IP66 T 135°C or T200°C Certification KEMA 01ATEX2124X and IECEx DEK 11.0017 Voltage AC/DC 110/240 VAC/DC Protection degree IP66 Ambient temp. range -60°C...+90°C

Description All Cameo Heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption. Our Cameo Direct Heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.

Part No. Classification Surface temp. Wattage CT-1A T3 Approx 115ºC 250-25 CT-2A T4 Approx 105ºC 250-25 CT-3A T4 Approx. 90ºC 250-25 CT-4A T4 Approx. 70ºC 250-25

*these temperatures are measured at 20°C ambient temperature.

24 25 Anti Condensation & Space Heater Type SAN-HEF Hazardous Area

The self-regulating properties of the HEF enclosure hea- ters eliminate the requirement for a thermostat. Coupled with the compact design, this makes the HEF ideal for anti condensation, frost protection and temperature control where the enclosure is located within Zone 1 and Zone 2 Hazardous Areas. Certified to ATEX Directive 94/9/EC IECEx, they are suitable for use where the flammable atmosphere is Group IIA, IIB or IIC Gas.

Features • Certified to meet the requirements of the ATEX Directive 94/9/EC, Gost and IECEx. • Compact, low profile, stainless steel case, requires minimal space. • Self-regulating - can be used without a thermostat. • Suitable for ambient temperatures from -60° to +80°C. • Mounting of the heater can be in any orientation. • Design allows installation close to internal components and cables without fear of damage by overheating.

Typical Applications: Control / monitoring panels Instrumentation cabinets Condensation prevention Temperature fluctuations Frost protection

Certification ATEX certified Ex II 2 G IECEx & ATEX certified Ex’e’ T4 EN/IEC60079-0 & EN/IEC60079-7

Casing Perforated stainless steel

Element Self-regulating

Controls The HEF is self-regulating, automatically reducing its output as the ambient temperature rises if overall enclosure temperature control is required it is recommended that the HEF heater is used in conjunction with one of the Ex’d’ thermostats.

Mounting The heater may be mounted in any orientation, using appropriate securing bolts through the mounting feet.

Rating The HEF range is available in a nominal 30, 50, 100, 200 & 500 Watt outputs, models available for 110V or 230-240V single phase supplies.

24 25 100W to 400W Space-saving Fan Heater HV/HVL 031 Series

• Compact • Flat design • High air flow • Temperature safety cut-out • Clip fixing

The compact high-performance fan heater prevents formation of condensa- tion in control or switch systems and provides an evenly distributed interior air temperature in enclosures. This fan heater is available without fan (HV 031) as well as with fan (HVL 031).

Technical Data: HV 031 Heater without fan (fan mounting kit included) HVL 031 Heater with fan Heating element High performance cartridge Temp. safety cut-out To protect against overheating in case of fan failure Heater body Die-cast aluminium (glass bead blasted) Connection 3-pole screw connector 2.5mm², clamping torque 0.8Nm max. Connection casing Plastic acc. to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Horizontal Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP20/I (earthed) Approvals UL file E187294 (230V only: VDE) HVL 031 only: Axial fan, ball bearing Airflow see table Service life 50,000h at 25°C Connection (axial fan) 2-pole screw connector 2.5mm2 (L2/N2)

a.) Clip Important! Heater may only be b.) Type plate operated together with fan. c.) Axial fan d.) Air direction Danger of overheating!

Art. No. HV 031 Art. No. HV 031 Heating capacity Dimensions Weight (approx.) 230VAC, 50/60Hz 120VAC, 50/60Hz 83275 100W 80x112 22mm 0.4kg 83276 150W 80x112x22mm 0.4kg 83277 200W 119x151x22mm 0.5kg 83278 300W 119x151x22mm 0.5kg 83279 400W 119x151x22mm 0.5kg

Art. No. HVL 031 Art. No. HVL 031 Heating capacity Airflow min., Dimension Weight (Approx.) 230VAC, 50/60Hz 120VAC, 50/60Hz free flow 83178 100W 35m3/h 80x112x47mm 0.6kg 83179 150W 35m3/h 80x112x47mm 0.6kg 83180 200W 108m3/h 119x151x47mm 0.9kg 83181 300W 108m3/h 119x151x47mm 0.9kg 83182 400W 108m3/h 119x151x47mm 0.9kg

26 27 up to 650W Semiconductor Fan Heater - CR 027 Series

• Compact heater • Heating capacity adjusts to ambient temperature • Adjustable temperature range • Clip fixing • Optical indicator • Temperature safety cut-out

Semiconductor fan heaters prevent the formation of condensation and ensure an even temperature in switch and control equipment. The built-in regulator is used to set the desired temperature.

Technical Data: Heating element PTC resistor, temperature limiting Temp. safety cut-out To protect against overheating in case of fan failure Axial fan, ball bearing Airflow see table service life 50,000h at 25°C Connection 2-pole clamp 2.5mm2, clamping torque 0.8Nm max. Casing Plastic, according to UL94 V-0, light grey Optical indicator Thermostat control lamp Mounting Clip for 35mm DIN rail, EN 60715 Fitting position Vertical Op./storage position -45 to +70ºC Dimensions 100 x 128 x 165mm Prot. type / Prot. class IP20 / II (double insulated) Approvals UL file E204590

Heating capacity / Ambient temperature Heating capacity / Ambient temperature diagram CR 027 (50Hz) diagram CR 027 (60Hz) Heating capacity (W) Heating capacity (W)

Temperature (ºC) Temperature (ºC)

Art. No. Operating Heating capacity* Heating capacity* Inrush Airflow, Setting range Weight voltage (50Hz) (60Hz) current max. free flow Temp. regulator (approx) 83285 220-240VAC, 50/60Hz 475W 550W 11.0A 35m3/h 0 to +60°C 0.9kg 83286 220-240VAC, 50/60Hz 550W 650W 13.0A 45m3/h 0 to +60ºC 1.1kg 83287 100-120VAC, 50/60Hz 400W 550W 14.0A 35m3/h +32 to +140°F 0.9kg 83288 100-120VAC, 50/60Hz 510W 650W 15.0A 45m3/h +32 to +140ºF 1.1kg * At 20ºC (68˚F) ambient temperature.

26 27 950W Compact high-performance Fan Heater - CR 030

• Compact design • Double insulated • Integrated thermostat or hygrostat

The compact high performance fan heater prevents formation of condensa- tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CR 130 is recommended.

Technical Data: Heating element High performance cartridge Temp. safety cut-out to protect against overheating in case of fan failure, automatic reset Heater body extruded aluminium profile Axial fan, ball bearing Airflow 160m3/h, free flow service life 50,000h at 25°C Connection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm max. Casing Plastic according to UL94-0, black Mounting Screw fixing (M5) Fitting position Horizontal Dimensions 168 x 145 x 100mm Weight Approx. 1.4kg Op.*/storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated) Note Other heating capacities from 200W up available on request.

*Operating temperature of heater with integrated hygrostat: 0 to +60°C

Connection diagram

Art. No. Model Operating voltage Heating capacity Setting range Approvals Fan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324* Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324* Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324* *according to UL499 in combination with UL508A

28 29 950W Compact high-performance Fan Heater - CR 130

• Compact design • Double insulated • Integrated thermostat or hygrostat • Optional clip or screw fixing

The compact high performance fan heater prevents formation of condensa- tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with integrated thermostat or pre-set hygrostat for temperature or humidity control. The CR 130 was designed as a stationary unit for wall fixing. For fix- ing on the bottom of the enclosure the fan heater CR 030 is recommended.

Technical Data: Heating element High performance cartridge Temp. safety cut-out to protect against overheating in case of fan failure, automatic reset Heater body Extruded aluminium profile Axial fan, ball bearing Airflow 160m3/h, free flow service life 50,000h at 25°C Connection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm max. Casing Plastic according to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6) Fitting position Horizontal Dimensions 182 x 160 x 99mm Weight Approx. 1.5kg Op.*/storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated) Note Other heating capacities from 200W up available on request.

*Operating temperature of heater with integrated hygrostat: 0 to +60°C

Connection diagram

Art. No. Model Operating voltage Heating capacity Setting range Approvals

Fan Heater with thermostat 230VAC, 50/60Hz 950W 0 to +60°C VDE + UL File No. E234324* Fan Heater with hygrostat 230VAC, 50/60Hz 950W 65% RH, factory-set VDE + UL File No. E234324* Fan Heater with thermostat 120VAC, 50/60Hz 950W +32 to +140°F UL File No. E234324*

*according to UL499 in combination with UL508A

28 29 1,200W Compact high-performance semiconductor Fan Heater - CS 030

• Compact design • High heating performance • Double insulated • Integrated thermostat (optional)

The compact high performance fan heater prevents formation of condensa- tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as pretection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 030 was designed as a stationary unit for the bottom of the enclosure. For wall fixing the fan heater CS 130 is recommended.

Technical Data: Heating element PTC resistor - temperature limiting Temp. safety cut-out to protect against overheating in case of fan failure Axial fan, ball bearing Airflow 160m3/h, free flow service life 50,000h at 25°C Connection 2-pole clamp max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm max. Casing Plastic according to UL94-0, black Mounting Screw fixing (M5) Fitting position Horizontal Dimensions 168 x 145 x 120mm Weight Approx. 1.2kg Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)

Heating capacity / Ambient temperature

30 diagram CS 030 Heating capacity (W)

Connection diagram Temperature (ºC)

Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals 83268 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242) 83269 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242) Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°C UL File No. E2343242) Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242) 1)at 20°C ambient temperature; 2)according to UL499 in combination with UL508A

30 31 1,200W Compact high-performance semiconductor Fan Heater - CS 130

• Compact design • High heating performance • Double insulated • Integrated thermostat (optional) • Optional clip or screw fixing

The compact high performance fan heater prevents formation of condensa- tion and provides an evenly distributed interior air temperature in enclosures with electric/electronic components. The plastic enclosure provides double insulation and acts as protection against contact. The fan heater is available with optional integrated thermostat for temperature control. The CS 130 was designed as a stationary unit for wall fixing. For fixing on the bottom of the enclosure the fan heater CS 030 is recommended.

Technical Data: Heating element PTC resistor - temperature limiting Temp. safety cut-out to protect against overheating in case of fan failure Axial fan, ball bearing Airflow 160m3/h, free flow service life 50,000h at 25°C Connection 2-pole max. 2.5mm2, clamping screw with strain relief, torque 0.8Nm max. Casing Plastic according to UL94 V-0, black Mounting Clip for 35mm DIN rail, EN 60715 or screw fixing (M6) Fitting position Horizontal Dimensions 182 x 160 x 120mm Weight Approx. 1.3kg Op.*/storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / II (double insulated)

Heating capacity / Ambient temperature diagram CS 130 Heating capacity (W)

Temperature (ºC) Connection diagram

Art. No. Model Operating voltage Heating capacity1) Inrush current max. Setting range Approvals 83266 Fan Heater with thermostat 230VAC, 50/60Hz 1,200W 13A 0 to +60°C VDE + UL File No. E2343242) 83267 Fan Heater without thermostat 230VAC, 50/60Hz 1,200W 13A - VDE + UL File No. E2343242) Fan Heater with thermostat 120VAC, 50/60Hz 1,200W 16A +32 to +140°F UL File No. E2343242) Fan Heater without thermostat 120VAC, 50/60Hz 1,200W 16A - UL File No. E2343242) 1)at 20°C ambient temperature; 2)according to UL499 in combination with UL508A

30 31 21m3/h to 102m3/h Filter Fan FF 018 Series

• Very low noise • Minimal depth in enclosure • Functional design • Time-saving installation • Weather proof and UV resistant

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec- tronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.

Technical Data: Axial fan, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic Connection 2 wires with pressure clamps 2.5mm2, length 100mm Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey; weather proof and UV light resistant according to UL746C (f1) Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out. Filter mat G4 acc. to DIN EN 779, filtering degree 94% Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP54* / I (earthed)

*Using fine filter mats type F5 increases the protection type to IP55, bt reduces the air volume.

Special features: • The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet. • Functional design of the intake and exit fan hoods very effectively prevents direct intrusion of falling water and dust. The advantage is that the filter mat does not get so quickly contaminated with dirt and thus does not need to be exchanged so often. • The air channelling makes the filter fan particularly quiet in operation. • Functional and modern design enables time-saving assembly and maintenance. • All filter fan models are also available with integrated airflow monitor. • EMC versions and other voltages on request. • The direction of air can easily be switched by reversing the axial fan (sizes 1 to 3).

Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.) exit filter tion tion ISO 4871) 230VAC, 21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm 0.6kg VDE + UL File 50Hz +0.4 No. E234324 230VAC, 55m3/h 42m3/h 100mA 15W 40dB (A) 58mm 125 x 1.0kg VDE + UL File 50Hz 125mm +0.4 No. E234324 230VAC, 102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 1.3kg VDE + UL File 50Hz 176mm +0.4 No. E234324 120VAC, 24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm 0.6kg UL File No. 60Hz +0.4 E234324 120VAC, 63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 1.0kg UL File No. 60Hz 125mm +0.4 E234324 120VAC, 117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 1.3kg UL File No. 60Hz 176mm +0.4 E234324

32 33 Filter Fan FF 018 Series Time-saving assembly and maintenance SAN’s filter fans are easily installed by one person from outside the cabinet.

1. Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, fillings and grease. A template for the enclosure cut- out is included in the delivery of the filter fan. 2. Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays perma- nently in the cabinet. (For size 176mm and up we recommend additional screw fixing.) 3. Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws. 4. Insert the filter mat in the hood. Clip on. Finished.

Changing the filter mat or fan is quickly done by one person. To change the filter Installation sketch mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2). Dimensional Drawing Size 1 Size 2 Size 3

Drilling template for mounting frame

Exit filter EF 118 Series

Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type 16mm 97x97mm +0.4 0.3kg G4 acc. to DIN EN 779, filtering degree 94% IP54* 16mm 125x125mm +0.4 0.4kg G4 acc. to DIN EN 779, filtering degree 94% IP54* 16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54*

*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.

Filter Mats FM 086 / FFM 086 Filter mat 89 x 89mm 118 x 118mm 168 x 168mm G4 (1 packing unit = 3 pcs) Art. no. Art. no. Art. no. F5 (1 packing unit = 3 pcs) Art. no. Art. no. Art. no.

Filter Fan with Airflow Monitor FFLC 218 (Normally Closed) Airflow monitor integrated in protective grille of filter fan, e.g. Art. no.

Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.) tion ISO 4871) 230VAC, 50Hz 21m3/h 16m3/h 80mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg 230VAC, 50Hz 55m3/h 42m3/h 100mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg 230VAC, 50Hz 102m3/h 68m3/h 100mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg 120VAC, 60Hz 24m3/h 18m3/h 160mA 13W 31dB (A) 45mm 97 x 97mm +0.4 0.6kg 120VAC, 60Hz 63m3/h 48m3/h 180mA 15W 40dB (A) 58mm 125 x 125mm +0.4 1.0kg 120VAC, 60Hz 117m3/h 78m3/h 180mA 15W 39dB (A) 86mm 176 x 176mm +0.4 1.3kg For techinal data see Airflow Monitor LC 013/LCF 013 (Normally Closed, NormallyOpen)

32 33 200m3/h Filter Fan FF 018 Series

• Low maintenance • High through-flow air volume • Functional design • Time-saving installation • Weather proof and UV resistant

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec- tronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.

Technical Data: Axial fan, ball bearing Service life 50,000h at 25°C (65% RH) Filter Fan fan body aluminium, rotor metal Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max. Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey; weather proof and UV light resistant according to UL746C (f1) Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter View from Exit filter fans is a template for the enclosure cut-out. rear Filter mat G4 acc. to DIN EN 779, filtering degree 94% Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP54* / I (earthed) *Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume. Airflow monitor integrated Drilling template in protective grille of filter for mounting Filter Fan FF 018 Series fan, e.g. Art. no. frame

Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.) exit filter tion tion ISO 4871) 230VAC, 200m3/h 125m3/h 320mA 45W 52dB (A) 95mm 176x176mm 1.7kg UL File No. 50Hz +0.4 E234324 120VAC, 230m3/h 143m3/h 470mA 39W 52dB (A) 95mm 176x176mm 1.7kg UL File No. 60Hz +0.4 E234324 Exit filter EF 118 Series Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type 16mm 176x176mm +0.4 0.6kg G4 acc. to DIN EN 779, filtering degree 94% IP54* *Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.

Filter Mats FM 086 / FFM 086 Filter mat 168x168mm G4 (1 packing unit = 3 pcs) Art. no. F5 (1 packing unit = 3 pcs) Art. no.

Filter Fan with Airflow Monitor FFLC 218 (Normally Closed) Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.) tion ISO 4871) 230VAC, 50Hz 200m3/h 125m3/h 320mA 45W 52dB (A) 95mm 176x176mm +0.4 1.7kg 120VAC, 60Hz 230m3/h 143m3/h 470mA 39W 52dB (A) 95mm 176x176mm +0.4 1.7kg

34 35 300m3/h Filter Fan FF 018 Series

• Very low noise • Minimal depth in enclosure • High through-flow air volume • Uniform air circulation • High reliability • Weather proof and UV resistant

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the elec- tronic components from overheating. Four integrated axial fans provide a particularly high and uniform air circulation thus contributing to higher reli- ability. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.

Technical Data: 4x Axial fan Axial fan, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor metal Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max. Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey; weather proof and UV light resistant according to UL746C (f1) Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo- sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out. Filter mat G4 acc. to DIN EN 779, filtering degree 94% View from Exit filter rear Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; mooisture resistant to 100% RH, reusable - cleaning by washing or vacuuming Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP54* / I (earthed)

*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.

Drilling template for mounting frame Filter Fan FF 018 Series

Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.) exit filter tion tion ISO 4871) 230VAC, 300m3/h 230m3/h 400mA 60W 53dB (A) 65mm 250x250mm 3.3kg UL File No. 50Hz +0.4 E234324 120VAC, 345m3/h 264m3/h 700mA 60W 53dB (A) 65mm 250x250mm 3.3kg UL File No. 60Hz +0.4 E234324

Exit filter EF 118 Series

Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type 22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*

*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume. Filter Mats FM 086 / FFM 086 Filter mat 247x247mm G4 (1 packing unit = 3 pcs) Art. no. F5 (1 packing unit = 3 pcs) Art. no.

34 35 550m3/h Filter Fan FF 018 Series

• High through-flow air volume • Functional design • Time-saving installation • Weather proof and UV resistant

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pocket and protects the electron- ic components from overheating. The high-performance axial fan provides high air circulation. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.

Technical Data: Filter Fan Axial fan, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor metal Connection 3-pole clamp for 2.5mm2, clamping torque 0.8Nm max. Casing (filter fan and exit filter) Plastic according to UL94-V-0, light grey Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey; weather proof and UV light resistant according to UL746C (f1) Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo- sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out. View from Exit filter rear Filter mat G4 acc. to DIN EN 779, filtering degree 94% Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean- ing by washing or vacuuming Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP54* / I (earthed)

*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume. Airflow monitor integrated in protective grille of filter Drilling template fan, e.g. Art. no. for mounting Filter Fan FF 018 Series frame

Art. No. Operating Air volume, Air volume Current Power Average noise Depth in Enclosure Weight Approvals voltage free flow with consump- consump- level (DIN EN enclosure cut-out (approx.) exit filter tion tion ISO 4871) 230VAC, 550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm 2.7kg UL File No. 50Hz +0.4 E234324 120VAC, 632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm 2.7kg UL File No. 60Hz +0.4 E234324

Exit filter EF 118 Series

Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type 22mm 250x250mm +0.4 1.0kg G4 acc. to DIN EN 779, filtering degree 94% IP54*

*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume. Filter Mats FM 086 / FFM 086 Filter mat 247x247mm G4 (1 packing unit = 3 pcs) Art. no. F5 (1 packing unit = 3 pcs) Art. no.

Filter Fan with Airflow Monitor FFLC 218 (Normally Closed)

Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.) tion ISO 4871) 230VAC, 50Hz 550m3/h 300m3/h 300mA 64W 65dB (A) 107mm 250x250mm +0.4 2.7kg 120VAC, 60Hz 632m3/h 345m3/h 780mA 85W 65dB (A) 107mm 250x250mm +0.4 2.7kg

36 37 Outdoor Filter Fan - FF 018 Series

• Filter changeable from outside • Safe, lockable • Impact resistant • Weather proof and UV resistant

The outdoor filter fan can be used in outdoor enclosures where warm air has to be dissipated on account of increased thermic development. To clean and exchange the filter mat, it is only necessary to open the lockable door of the outdoor hood. A protection type of IP55 is achieved due to the special de- sign of the hood and the use of fine filter mats. The plastic casing is impact resistant, highly weather proof and resistant to UV light.

Outdoor Filter Fan

Technical Data: Axial fan, ball bearing Service life min. 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic Connection 2 wires with pressure clamps 2.5mm2, length 100mm Casing (filter fan and exit filter) Casing material high impact plastic ASA, light grey burning behaviour ac- cording to UL94 H-B; high resistance to weather and UV Mounting frame with double-sided industrial adhesive band for fixing to the outside of enclo- sure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out. Filter mat F5 acc. to DIN EN 779, filtering degree 98% Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP55 / I (earthed) Approvals UL File No. E234324 View from Outdoor Exit filter rear The hood is fixed permanently to the enclosure from the inside using screws. Filter mats can be easily changed from outside the enclosure through the lockable door in the hood.

Drilling template for mounting Filter Fan with Airflow Monitor FFLC 218 (Normally Closed) frame

Art. No. Operating voltage Air volume, Current con- Power Average noise level Depth in Enclosure cut-out Weight free flow sumption consump- (DIN EN ISO 4871) enclosure (approx.) tion 230VAC, 50Hz 20m3/h 100mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg 120VAC, 60Hz 23m3/h 180mA 15W 40dB (A) 62mm 125x125mm +0.4 1.2kg

Exit filter EF 118 Series

Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type 16mm 125x125mm +0.4 0.6kg F5 acc. to DIN EN 779, filtering degree 98% IP55

Filter Mats FFM 086 Filter mat 122x122mm F5 (1 packing unit = 3 pcs) Art. no.

36 37 350m3/h Low noise Roof Filter Fan - RFF 018 Series

• Very low noise • Minimal depth in enclosure • High through-flow air volume • Uniform air circulation • High reliability • Time-saving installation

Roof filter fans and roof exit filters find use in enclosures, from which warm air has to be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan, which houses four axial fans, is used to expel warm air from within the enclosure which has been generated by the stray power of the components. The roof exit filter provides . Roof Filter Fan RFF 018

Technical Data: Axial fans, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic Connection 3-pole clamp for 2.5mm2 Casing Plastic according to UL94-V-0 / lacquered steel sheet, light grey Filter mat G3 acc. to DIN EN 779, filtering degree 85% Filter material Synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH, reusable - clean- ing by washing or vacuuming Op./storage temp. -45 to +70ºC Prot. type IP43 (with filter mat G3 / IP33 (without filter mat) Prot. class I (earthed) Approvals UL FIle No. E234324 View from Roof Exit filter below REF 118 Important note: For reasons of pressure compensation the roof filter fan must always be operated in combi- nation with another filter fan (e.g. Art. No. ) or a passive intake filter (e.g. Art. No.). Hole centers

Enclosure cut-out Roof Filter Fan RFF 018 Series

Art. No. Operating Air volume, Air volume with Current con- Power Average noise Depth in Enclosure cut-out Weight voltage free flow exit filter sumption consump- level (DIN EN enclosure (approx.) tion ISO 4871) 230VAC, 50Hz 350m3/h (w/ 500m3/h (w/o 400mA 60W 55dB (A) 44mm 250x250mm +0.4 4.4kg filter mat G3) filter mat) 120VAC, 60Hz 402m3/h (w/ 575m3/h (w/o 700mA 60W 55db (A) 44mm 250x250mm +0.4 4.4kg filter mat G3) filter mat)

Roof Exit filter REF 118 Series

Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type none 250x250mm +0.4 2.0kg G3 acc. to DIN EN 779, filtering degree 85% IP43 (w/filter mat)

Filter Mats FM 086 Filter mat 282x282mm G3 (1 packing unit = 3 pcs) Art. no.

38 39 High-performance 19” Fan Tray - LE 019 Series

• High air output • Long service life • Ball bearing fans • Ready for connection • Optical function indicator

Compact high performance fan tray for enforced circulation of air in switch and server enclosures and for concerted cooling of 19” component groups. Natural convection is improved and the formation of localised hot pockets is avoided. Also available with integrated thermostat (see photo).

Technical Data: Axial fans, ball bearing Service life 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic Material Front panel aluminium, bright anodised casing steel sheet, electrogalvanized Optical indicator Integrated in front panel Connection Appliance power inlet on rear of casing, plug included Fitting position Horizontal (direction of air upwards) Op./storage temp. -45 to +70ºC Prot. type / Prot. class IP20 / I (earthed) Approvals UL FIle No. E234324

Note: We recommend using the fan tray in combination with our dual thermostat (ZR 011) for regulating temperature in electronic enclosures and for protection against overheating due to possible fan failure. The dual ther- mostat regulates the operation of the fan tray and when connected to a signal device also triggers an early warning if the enclosure interior temperature rises above a set limit.

When using a fan tray with integrated thermostat, the use of an additional thermostat (KTS 011) provides the extra safety of activating a signal device.

Art. No. Model No. of Operating Air flow, Power Average noise Speed (rpm-1) Impact Weight fans voltage free flow consumption level (DIN EN pressure (approx.) ISO 4871) without thermostat 3 230VAC, 50Hz 486m3/h 45W 55dB (A) 2600 min-1 (50Hz) 74Pa 3.0kg with thermostat 0 to +60°C 3 230VAC, 50Hz 486m3/h 45W 55db (A) 2600 min-1 (50Hz) 74Pa 3.4kg without thermostat 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.3kg with thermostat 0 to +60°C 6 230VAC, 50Hz 972m3/h 90W 57dB (A) 2600 min-1 (50Hz) 74Pa 5.7kg without thermostat 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.8kg with thermostat 0 to +60°C 9 230VAC, 50Hz 1458m3/h 135W 58dB (A) 2600 min-1 (50Hz) 74Pa 7.9kg without thermostat 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.0kg with thermostat 0 to +60°C 3 120VAC, 60Hz 576m3/h 45W 55dB (A) 2900 min-1 (60Hz) 88Pa 3.4kg without thermostat 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.3kg with thermostat 0 to +60°C 6 120VAC, 60Hz 1152m3/h 90W 57dB (A) 2900 min-1 (60Hz) 88Pa 5.7kg witout thermostat 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.8kg with thermostat 0 to +60°C 9 120VAC, 60Hz 1728m3/h 135W 58dB (A) 2900 min-1 (60Hz) 88Pa 7.9kg

38 39 24VDC + 48VDC

Switch Module SM 010

• High DC switching capacity • Variety of applications • Compact design • Simple connection • Cliip fixing

Switch module for switching DC appliances with high switching capacity. A separate conventional switch contact is used as controller (e.g. temperature regulator, humidity regulator). The switch module is available in 24VDC and 48VDC versions.

Technical Data: Contact type Contact maker, normally open (Relay/MOSFET) Contact resistance <10mΩ Service life >100,000 cycles EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 6-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 67x50x46mm Weight Approx. 90g Fitting position Variable Op./storage temp. -45 to +70°C Protection type IP20 Approvals VDE submitted e.g. Temperature regulator

e.g. Heater Power supply

Load e.g. heater, Switch Module, Control contact, Load, e.g. heater, Switch Module, Control contact, cooling device with SM 010 e.g. temperature, cooling device without SM 010 e.g. temperature, temperature cut-out humidity or pressure temperature cut-out humidity or pressure regulator regulator

Fan

Art. No. Operating voltage Max. Switching capacity 24VDC (20-28VDC) 28VDC 16A 48VDC (38-56VDC) 56VDC 16A

40 41 Small, compact Thermostat - KTO/KTS 011

• Large setting range • Small size • Simple to mount • High switching performance

KTO 011: Thermostat (normally closed), contact breaker for regulating heat- ers. KTS 011: Thermostat (normally open), contact maker for regulating of filter fans and heat exchangers or for switching signal devices when temperature limit has been exceeded.

Technical Data: Switch temperature difference 7K (±4K tolerance) Sensor element Thermostatic bimetal Contact type Snap-action contact Contact resistance <10mΩ Service life >100,000 cycles Max. switching capacity 250VAC, 10 (2) A 120VAC, 15 (2) A DC 30W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 2-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 (or for exit filter EF 118 Series) Casing Plastic according to UL94 V-0, light grey Dimensions 60x33x43mm Weight Approx. 40g Fitting position Variable Thermostat Thermostat Op/storage temp. -45 to +80°C KTO 011 (NC) KTS 011 (NO) Protection type IP20

Thermostat Heater Thermostat e.g. Fan Thermostat e.g. Signal KTO 011 (NC) KTS 011 (NO) KTS 011 (NO) device Heater

Filter fan, Cooling equipment, Signal device

Example of connection Connection diagrams

Setting range Art. No. Contact Breaker (NC) Art. No. Contact Maker (NO) Approvals 0 to +60°C VDE -10 to +50°C VDE +20 to +80°C VDE +32 to +140°F UL File No. E164102 +14 to +122°F UL File No. E164102 0 to +60°C UL File No. E164102

40 41 Tamperproof (Pre-set) Thermostats - FTO/FTS 011

• Small size • Default temperature settings • Easy to install • High switching tolerance

Tamperproof (Pre-set) Thermostat FTO 011 Contact breaker / NC (red casing) for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising. Tamperproof (Pre-set) Thermostat FTS 011 Contact maker / NO (blue casing) for regulating filter fans, heat exchangers, cooling devices or for switching signal devices when temperature limit has been exceeded. The contact closes when temperature is rising.

Technical Data: Sensor element Thermostatic bimetal Contact type Snap-action contact Contact resistance <20mΩ Service life >100,000 cycles Max. switching capacity 250VAC, 5 (1.6) A 120VAC, 10 (2) A DC 30W Max. inrush current AC 10A EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 2-pole terminal for 2.5mm2, torque 0.8Nm max. Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 47x33x33mm Weight Approx. 30g Fitting position Variable Op/storage temp. -20 to +80°C / -45 to +80°C Protection type IP20 Approvals VDE + UL File No. E164102

Heater Filter fan Signal device Thermostat Thermostat Thermostat FTO 011 FTS 011 FTS 011

Example of connection

Art. No. Contact Switch-off temperature Switch-on temperature Contact breaker (NC) +15°C (±5K tolerance) +5°C (±5K tolerance) Contact breaker (NC) +25°C (±5K tolerance) +15°C (±5K tolerance) Switch-on temperature Switch-off temperature Contact maker (NO) +50°C (±6K tolerance) +40°C (±7K tolerance) Contact maker (NO) +60°C (±6K tolerance) +50°C (±7K tolerance) Contact maker (NO) +35°C (±6K tolerance) +25°C (±7K tolerance)

42 43 Dual Thermostat - ZR 011

• NO and NC in one casing • Separate adjustable temperatures • High switching capacity • Terminals easily accessible • Clip fixing

Two thermostats in one casing: Thermostat (contact breaker, normally closed) for regulating heaters. Thermostat (contact maker, normally open) for regulating filter fans and heat exchangers or switching signal devices when temperature limit has been exceeded.

Heaters and cooling equipment can be switched indepen- dently from each other with a temperature offset as op- posed to the usual change-over contacts.

Technical Data: Switch temperature difference 7K (±4K tolerance) Sensor element Thermostatic bimetal Contact type Snap-action contact Contact resistance <10mΩ Service life >100,000 cycles Max. switching capacity 250VAC, 10 (2) A 120VAC, 15 (2) A DC 30W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 4-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 67x50x46mm Weight Approx. 90g Fitting position Variable Thermostat Op/storage temp. -45 to +80°C ZR 011 (NC/NO) Protection type IP20 Approvals UL File No. E164102

Heater

Filter fan, Cooling equipment, Signal device

Connection diagram

Art. No. Setting Range Setting Range contact breaker, normally closed 0 to +60°C Contact maker, normally open 0 to +60°C contact breaker, normally closed +32 to +140°F Contact maker, normally open +32 to +140°F contact breaker, normally closed -10 to +50°C Contact maker, normally open +20 to +80°C contact breaker, normally closed +14 to +122°F Contact maker, normally open +68 to +176°F Contact maker, normally open 0 to +60°C Contact maker, normally open 0 to +60°C Contact maker, normally open +32 to +140°F Contact maker, normally open +32 to +140°F

42 43 Tamperproof (Pre-set) Dual-Thermostat - FTD 011

• NO and NC in one casing • Default temperature settings • High switching accuracy • Clip fixing

Two thermostats in one casing: Tamperproof (Pre-set) Thermostat/Contact breaker (NC) for regulating heaters or for switching signal devices when temperature has fallen below the minimum value. The contact opens when temperature is rising. Tamperproof (Pre-set) Thermostat/Contact maker (NO) for regulating filter fans, heat exchangers or for switching signal devices when temperature limit has been exceeded. The contact closes when temperature is rising.

Heaters and cooling equipment can be switched independently from each other with a temperature offset as opposed to the usual change-over contacts.

Technical Data: Sensor element Thermostatic bimetal Contact type Snap-action contact Contact resistance <20mΩ Service life >100,000 cycles Max. switching capacity 250VAC, 5 (1.6) A 120VAC, 10 (2) A DC 30W Max. inrush current AC 10A EMC ac. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 4-pole terminal for 12.5mm2, torque 0.8Nm max. Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 47x63x33mm Weight Approx. 40g Fitting position Variable Op/storage temp. -20 to +80°C / -45 to +80°C Protection type IP20 Approvals VDE + UL File No. E164102

Heater Filter fan

Thermostat FTD 011

Example of connection

Art. No. Contact breaker (NC) Contact maker (NO) Switch-off temperature Switch-on temperature Switch-on temperature Switch-off temperature +15°C (±5K tolerance) +5°C (±5K tolerance) +50°C (±6K tolerance) +40°C (±7K tolerance) +25°C (±5K tolerance) +15°C (±5K tolerance) +60°C (±6K tolerance) +50°C (±7K tolerance) +15°C (±5K tolerance) +5°C (±5K tolerance) +35°C (±6K tolerance) +25°C (±7K tolerance) +25°C (±5K tolerance) +15°C (±5K tolerance) +50°C (±6K tolerance) +40°C (±7K tolerance) Art. No. Contact maker (NO) Contact maker (NO) Switch-on temperature Switch-off temperature Switch-on temperature Switch-off temperature +50°C (±6K tolerance) 40°C (±7K tolerance) +60°C (±6K tolerance) +50°C (±7K tolerance)

44 45 Mechanical Thermostat - FZK 011

• Adjustable temperature • High switching capacity • Small hysteresis • Terminals easily accessible • Clip fixing • Change-over contact

The mechanical thermostat is used for controlling heating and cooling equip- ment, filter fans or signal devices. The thermostat registers the surrounding air and can switch both inductive and resistive loads via snap-action contact.

Technical Data: Switch temperature difference 4K (±1.5K tolerance)* Sensor element Thermostatic bimetal Contact type Change-over snap-action contact Contact resistance <10mΩ Service life >100,000 cycles Max. switching capacity, NC 250VAC, 10 (4) A 120VAC, 10 (4) A DC 30W Max. switching capacity, NO 250VAC, 5 (2) A 120VAC, 5 (2) A DC 30W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 4-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Connection diagram Dimensions 67x50x38mm Weight Approx. 0.1kg Fitting position Variable Enclosure heater Op/storage temp. -20 to +80°C / -45 to +80°C Protection type IP20

Approvals UL File No. E164102 Filter fan, *Connecting terminal “N” (RF heating resistor) causes the thermal feedback to work and so reduces the switch Cooling equipment, temperature difference to approx. 0.5K. Signal device e.g. Filter fan Heater Thermostat FZK 011 for cooling Thermostat FZK 011 e.g. Signal device Thermostat FZK 011

Examples of connection

Art. No. Operating voltage Setting range 230VAC +5 to +60°C 230VAC +40 to +140°F 230VAC -20 to +30°C 120VAC +40 to +140°F 120VAC +5 to +60°C

44 45 (24VDC) Electronic Thermostat - ET 011

• High DC breaking capacity • Low hysteresis • Adjustable temperature • Change-over contact • Clip fixing

Electronic thermostat for regulating high performance DC 24V equipment. Heating or cooling appliances as well as signal devices can be switched via the potential free change-over contact. In comparison to mechanical thermo- stats, the ET 011 has a low hysteresis making the switchng point and setting accuracy more precise.

Technical Data: Switch temperature difference Approx. 3K Sensor element PTC Contact type Change-over Contact resistance <10mΩ Service life >100,000 cycles Max. switching capacity 28VDC, 16A EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 5-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 67x50x46mm Weight Approx. 80g Fitting position Vertical Op/storage temp. 0 to +60°C / -45 to +80°C Protection type IP20 Approvals -

Connection diagram

e.g. Filter fan Thermostat ET 011 Heater Thermostat ET 011 for cooling Thermostat ET 011 e.g. Signal device

Examples of connection

Art. No. Operating voltage Setting range 24VDC (20-28VDC) 0 to +60°C

46 47

Ex FixTherm96 Thermostat

The Ex FixTherm96-Thermostats are often used as maximum thermo- stat in instrumentation cabinets with • Prevention of overheating • Temperature controlling

Features and Advantages • Setpoints up to 135°C • Accurate set-point (± 3°C) • Small hysteresis • Anodized Aluminium housing ( Stainless steel housing available) • Armoured electrical cable standard • Suitable for T6 and T4 classification • Can be used for 6A / 240 VAC/DC

Technical Data: Housing Anodized aluminium or stainless steel Current / voltage 6A / 240 VAC Cable 3x 0,75 sqmm Material cable silicone braided cable, optional: non-braided cable Standard length Approx. 1 mtr Other lengths On request Overall dimensions o.d. 30mm x 49mm length Weight Approx. 160g Switch SPST Set-point tolerance +/-3ºC Hysteresis Approx. 2ºC Mounting bracket avaliable (B) Ambient temp. range -50ºC...+90ºC EX protection class II 2G Ex d IIC T6 or T4 II 2D Ex tD A21 IP66T T 85ºC orT 135ºC Certification KEMA 01ATEX2125X and IECEx DEK 11.0017

Description The housing is made from anodized Aluminium or Stainless Steel type 316 (on request).

When required in other applications, e.g. analyzers, it is normal practice to use our Space-heaters in combination with these Fix-Therm96 thermostats (range from 10°C up to 135°C). The FixTherm96 can also be used for cooling purpo- ses e.g. FixTherm TH-10/5F.

Range Aluminium: TH-10/5 – going up with 5°C setpoints e.g. 10/5“ 15/10“ 20/15 etc. up to 135°C maximum.

Stainless Steel bodies: identical range.

46 47 Electrical Thermostat Ex FixTherm96 General Purpose SAN-GTH*/* For Non-Hazardous areas the General Purpose FixTherm96 thermostats are very suitable. Often used as maximum ther- mostat in instrumentation cabinets with space heating, to protect the equipment from overheating. Or as a minimum thermostat with space heating to protect from freezing.

In short, temperature maintenance: • Prevention of overheating • Freeze protection • Anticondensation

Technical Data: Housing Anodized aluminium Current / voltage 6A / 240 VAC Cable 3x 0,75 sqmm Material cable Non-braided silicone cable Standard length Approx. 1 mtr, other lengths optional Overall dimensions 30mm x 58mm (diameter xH) Weight Approx. 160g Switch SPST Set-point tolerance +/-3ºC Hysteresis Approx. 2ºC Mounting bracket avaliable (B) protection IP66

Features and Advantages

• Setpoints from 10°C up to 130°C • Accurate set-point - (N.C. contact) • Small hysteresis • Anodized aluminium housing (Stainless steel housing available) • Inside grounding • Can be used for 110 / 240 VAC/DC

Description

The housing is made from anodized aluminium. When required in other applications, e.g. analyzers, it is normal prac- tice to use our Space-heaters in combination with our Fix-Therm96 thermostats (range from 10°C up to 130°C). The FixTherm96 can also be used for cooling purposes e.g. FixTherm96 TH-10/5F (N.O. contact).

Range

GTH-10/5 - going up with 5°C each time e.g. 10/5 - 15/10 - 20-15 etc. up to 130°C maximum.

48 49 Mechanical Hygrostat - MFR 012

• Adjustable relative humidity • Change-over contact • High switching capacity • Easily accessible terminals • Clip fixing

The electromechanical hygrostat MFR 012 is designed to control enclosure heaters so that the dew point is raised when a critical relative humidity of 65% is exceeded. In this way condensation and corrosion is effectively pre- vented.

Technical Data: Switch difference* 4% RH (±3% tolerance) Permissible air velocity 15m/sec Contact type Change-over contact Contact resistance <10mΩ Service life >100,000 cycles Min. switching capacity 20V AC/DC, 100mA Max. switching capacity 250VAC, 5 (1) A DC 20W EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Connection 3-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 67x50x38mm Weight Approx. 60g Fitting position Variable Op/storage temp. 0 to +60°C / -20 to +80°C Protection type IP20 Approvals UL File No. E164102

*at 50% RH.

Heater Hygrostat Hygrostat Filter Fan Enclosure heater MFR 012 MFR 012

Filter fan, Cooling equipment, Signal device Connection diagram

Examples of connection

Art. No. Setting range 32038 35 to 95% RH

48 49 Electronic Hygrostat - EFR 012

• Adjustable and pre-set relative humidity • Optical operating display (LED) • High switching capacity • Clip fixing • Temperature-compensated

The electronic hygrostat senses the relative humidity in an enclosure with electric/electronic components, and turns on a heater at the set point, help- ing prevent the formation of condensation in the enclosure. The LED integrat- ed in the adjustment knob is lit when the connected heater is in operation.

Technical Data: Switch difference 5% RH (±1% RH tolerance) at 25°C (50% RH) Reaction time Approx. 5 sec. Contact type Change-over contact (relay) Service life >50,000 cycles Max. switching capacity (relay 240VAC, 8 (1.6) A output) 120VAC, 8 (1.6) A 24VDC, 4A EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Optical indicator LED Connection 5-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 64.5x42x38mm Weight Approx. 70g Fitting position Vertical Op/storage temp. 0 to +60°C / -20 to +70°C Max storage humidity 90% RH (without condensation) Protection type IP20

Hygrostat Heater EFR 012

4 Heater

Connection diagram

Example of connection

Art. No. Operating voltage Setting range Approvals 230VAC, 50/60Hz 40 to 90% RH VDE, (UL intended) 230VAC 50/60Hz 65% RH pre-set VDE; (UL intended) 120VAC, 50/60Hz 40 to 90% RH UL intended 120VAC, 50/60Hz 65% RH pre-set UL intended

50 51 Electronic Hygrotherm - ETF 012

• Temperature and humidity adjustable • Optical operating display (LED) • High switching capacity • Clip fixing

The electronic hygrotherm senses the ambient temperature and relative humidity in an enclosure with electric/electronic components, and turns on a heater (or alternatively, a fan) at either set point, helping prevent the formation of condensation in the enclosure. The LED integrated in the adjustment knob on the active controller is lit when the connected device is in operation.

Technical Data: Switch difference (temperature) 2K (±1K tolerance) at 25°C (50% RH) Switch difference (humidity) 4% RH (±1% tolerance) at 25°C (50% RH) Reaction time (humidity) Approx. 5 sec. Contact type Change-over contact (relay) Contact resistance <10mΩ Service life NC >50,000 cycles NO >100,000 cycles Max. switching capacity (Relay NC 240VAC, 6 (1) A out-put) NO 240VAC, 8 (1.6) A NC 120VAC, 6 (1) A NO 120VAC, 8 (1.6) A 24VDC, 4A EMC acc. to EN 55014-1-2, EN 61000-3-2, EN 61000-3-3 Optical indicator LED Connection 5-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm2 stranded wire (with wire end ferrule) 1.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic according to UL94 V-0, light grey Dimensions 77x60x43mm Weight Approx. 0.2kg Fitting position Vertical Op/storage temp. 0 to +60°C / -20 to +80°C Protection type IP20

Hygrotherm Heater ETF 012

Connection diagram

Example of connection

Art. No. Operating volt- Setting range Setting range humidity Approval age temperature 230VAC, 50/60Hz 0 to +60°C 50 to 90% RH VDE + UL FIle No. E164102 120VAC, 50/60Hz +32 to +140°F 50 to 90% RH UL File No. E164102 120VAC, 50/60Hz 0 to +60°C 50 to 90% RH UL File No. E164102

50 51 15°C, 25°C Hazardous area Thermostat - REx 011 Series

• Compact design • Set temperature • High switching capacity

Compact small mechanical thermostat for temperature regulation and moni- toring of heaters in, for example, transmitter cabinets, control panels and measuring equipment which are deployed in areas with explosion hazard. The special switch construction enables high response accuracy, small switch temperature difference and a very long service life. High switching performance allows direct control of the heaters.

Technical Data: Explosion proof acc. to EN LCIE (Laboratoire Central des Industries Electriques) Conformity certificate 01 ATEX 6074/02, LCIE Nº 06 ATEX 08011, IECEx LCI 07. 0021 Sensor element Thermostatic bimetal Contact type (1-pole) Opens with rising temperature Service life >100,000 cycles Max. switching capacity 250VAC, 4 (1) A Connection Si HF - JZ 3x0.75mm2, length 1m Mounting mounting bracket with nut M8 (see illustration) Casing Aluminium, black anodised Dimensions length 110mm Weight Approx. 0.2kg Fitting position Variable Op/storage temp. -20 to +40°C / -45 to +70°C Prot. type/ Prot. class IP65 / I (earthed)

Aluminium Mounting Bracket

Art. No. Ex protection type Swich-off temperature Switch temperature difference d IIC T6 - Ex tD A21 IP6X T85°C +15°C (±4K tolerance) 4K (±1K tolerance) d IIC T6 - Ex tD A21 IP6X T85°C +25°C (±4K tolerance) 4K (±1K tolerance)

52 53 with on/off switch Slimline Lamp - SL 025 Series

• Slim casing • Electronic ballast • Lamp without/with electrical socket (choice of sockets) • Magnet fixing (option) • Energy saving lamp • On/Off switch

The flat slimline lamp SL 025 is suitable for all types of panels and enclo- sures, especially where space is at a premium. The lamp can be mounted on its narrow or broad surface using screws. It is also available with a magnet which allows it to be fitted quickly in any position in a steel enclosure. Both versions are available with an integrated electrical socket enabling the use of additional appliances. Photo: Slimline lamp with on/off switch, with inte - Photo: Slimline lamp with on/off grated electric socket (Germany), Art No.

Technical Data: Power consumption 11W (equals 75W light bulb) Luminosity 900Lm Lamp type Energy saving lamp, 2G7 socket Service life 10,000h Switch On/off light switch Connection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max. Mounting Screw fixing, M5, 300mm centers magnet fixing (optional) Casing Plastic acc. to UL94 V-0, light grey Dimensions 345x91x40mm Fitting position Narrow surface/broad surface Op/storage temp. -20 to +50°C / -45 to +75°C Protection type IP20 Note The slimline lamp SL 025 is also available with a 19” front panel 24VDC to 48VDC on request

Art. No. Model Operating volt- Socket Nominal Current Weight Protection class Approvals age (approx) without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324 with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324 without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324 with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324 with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324

52 53 with movement sensor Slimline Lamp - SL 025 Series

• Slim casing • Electronic ballast • Lamp without/with electrical socket (choice of sockets) • Magnet fixing (option) • Energy saving lamp • On/Off switch

The flat slimline lamp SL 025 with movement sensor is suitable for all types of panels and enclosures, especially where space is at a premium. The lamp can be mounted on its narrow or broad surface using screws. It is also available with a magnet which allows it to be fitted quickly in any position in a steel enclosure. Both versions are available with an integrated electri- cal socket enabling the use of additional appliances. The movement sensor substitutes a door contact switch. Photo: Slimline lamp with movement sensor and integrated electric socket (Germany), Art No.

Technical Data: Power consumption 11W (equals 75W ligth bulb) Luminosity 900Lm Lamp type Energy saving lamp, 2G7 socket Service life 10,000h Swittch PIR movement sensor, approx. 6min. fixed switch-on duration Connection Terminal 2.5mm2 with cable clamp, torque 0.8Nm max. Mounting Screw fixing, M5, 300mm centers magnet fixing (optional) Casing Plastic acc. to UL94 V-0, light grey Dimensions 345x91x40mm Fitting position Narrow surface/broad surface Op/storage temp. 20 to +50°C / -45 to +70°C Protection type IP20 Note The slimliine lamp SL 025 is also available with a 19” front panel 24VDC to 48VDC on request

The PIR movement sensor switches the lighting on when the enclosure door is opened. The switch-on timne is reset with every further registered movement. The movement sensor does not react to mevement on the other side of glass and so can be used in enclosures with glass doors.

Art. No. Model Operating volt- Socket Nominal Current Weight Protection class Approvals age (approx) without magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz Germany/Russia (1) 16.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz F/PL/CZ/SK (2) 16.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz Switzerland (3) 10.0A 0.5kg I (earthed) VDE without magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.4kg I (earthed) VDE with magnet 230VAC, 50/60Hz UK/Ireland (4) 13.0A 0.5kg I (earthed) VDE without magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.4kg I (earthed) UL File No. E234324 with magnet 120VAC, 50/60Hz USA/Canada (5) 15.0A 0.5kg I (earthed) UL File No. E234324 without magnet 230VAC, 50/60Hz none - 0.4kg II (double insulated) VDE + UL File No. E234324 with magnet 230VAC, 50/60Hz none - 0.5kg II (double insulated) VDE without magnet 120VAC, 50/60Hz none - 0.4kg II (double insulated) UL File No. E234324 with magnet 120VAC, 50/60 Hz none - 0.5kg II (double insulated) UL File No. E234324

54 55 On/off switch Dual Lamp - DL 026 Series

• Versatile - base lamp or hand lamp • Long-life energy saving lamp • Connections for further lamps Dual lamp with on/off switch (incl. base station) Dual lamp with on/off

Technical Data: Luminosity 1000Lm Lamp type Energy saving lamp, E27 socket Service life 10,000h Switch On/off push switch Connection 6-pole screw connector 2.5mm2 (torque 0.5Nm max.) for power connection, further lamps and external door contact switch Mounting Screw fixing, (e.g. 35mm DIN rail) Casing Plastic acc. to UL94 V-0, light grey Weight Approx. 0.6kg Fitting position Variable Op/storage temp. -20 to +50°C / -45 to +70°C Prot. type/prot. class IP20 / II (double insulated) Approvals - Accessories Wall holder with connection cable (2m), hook and fixing plate Note 120VAC and DC voltages on request

1. Standard screw fixing to DIN rail 2. 2 self-adhesive fixing plates 3. Wall holder with connection cable (2m), hook and self-adhesive fixing plate By using an additional wall holder the lamp can be used as a hand lamp.

Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)

54 55 Movement sensor Dual Lamp - DL 026 Series

• Versatile - base lamp or hand lamp • Long-life energy saving lamp • Automatic switching • Alternative solution for door switch • Connections for further lamps Dual lamp with movement sensor (incl. base station)

Technical Data: Luminosity 1000Lm Lamp type Energy saving lamp, E27 socket Service life 10,000h Switch PIR movement sensor, approx. 3min. fixed switch-on duration Connection 4-pole screw connector 2.5mm2 (torque 0.5Nm max.) for power connection and further lamps Mounting Screw fixing, (e.g. 35mm DIN rail) Casing Plastic acc. to UL94 V-0, light grey Weight Approx. 0.6kg Fitting position Variable Op/storage temp. -20 to +50°C / -45 to +70°C Prot. type/prot. class IP20 / II (double insulated) Approvals - Accessories Wall holder with connection cable (2m), hook and fixing plate Note 120VAC and DC voltages on request

The PIR movement sensor switches the lamp on when the enclosure door is opened. The switch-on time is reset with every further registered movement. The movement sensor does not react to mevement on the other side of glass and so can be used in enclosures with glass doors.

1. Standard screw fixing to DIN rail 2. 2 self-adhesive fixing plates 3. Wall holder with connection cable (2m), hook and self-adhesive fixing plate By using an additional wall holder the lamp can be used as a hand lamp.

Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)

56 57 With lamp holder Hand Lamp - DL 026 Series

• Long-life energy saving lamp • Versatile

Technical Data: Luminosity 1000Lm Lamp type Energy saving lamp, E27 socket Service life 10,000h Connection Power cable (2m) with Euro plug Mounting Screw or fixing plate (self-adhesive) Casing Plastic acc. to UL94 V-0, light grey Weight Approx. 0.6kg Fitting position Variable Op/storage temp. -20 to +50°C / -45 to +70°C Prot. type/prot. class IP20 / II (double insulated) Approvals - Accessories Lamp holder, hook and fixing plate Note 120VAC and DC voltages on request

Art. No. Operating voltage Power Consumption 230VAC, 50Hz 20W (equals 100W light bulb)

56 57 Compact Lamp - KL 025 Series

• Magnetic or optional DIN rail mounting • Energy-saving lamp • Lamp without(with electrical socket (choice of sockets) • On/off switch

The compact lamp KL 025 was especially designed for use in enclosures. A powerful magnet enables the lamp to be mounted freely in any desired position in metal enclosures saving time and installation problems. The integrated elec- trical socket allows the use of additional appliances. Lamp shown with protective plastic cover (see Acessories) Lamp shown with protective

Technical Data: Luminosity 900Lm Lamp type Compact fluorescent lamp with integral starter Service life 5,000h Switch On/off light switch Connection 3-pole terminal 2.5mm2 with cable clamp, torque 0.8Nm max. Mounting Magnet fixing Casing Plastic, light grey Dimensions 355x65x70mm Weight Approx. 1kg Fitting position Variable Op/storage temp. -20 to +50°C / -45 to +70°C Protection type IP20 Accessories Lamp cover, Art. No. (see photo)

Magnet

In plastic, aluminium or stainless steel cabinets the lamp can be fixed using screws together with inserted 35mm DIN rail sections.

Art. No. Operating voltage Socket Power consumption Nominal Current Protection class Approvals 230VAC, 50Hz Germany/Russia (1) 11W (equals 75W light bulb) 16.0A I (earthed) VDE 230VAC, 50Hz none 11W (equals 75W light bulb) - II (double insulated) - 230VAC, 50Hz F/PL/CZ/SK (2) 11W (equals 75W light bulb) 16.0A I (earthed) - 230VAC, 50Hz Switzerland (3) 11W (equals 75W light bulb) 10.0A I (earthed) - 230VAC, 50Hz UK/Ireland (4) 11W (equals 75W light bulb) 13.0A I (earthed) - 230VAC, 50Hz Italy (6) 11W (equals 75W light bulb) 16.0A I (earthed) - 120VAC, 60Hz USA/Canada (5) 9W (equals 60W light bulb) 15.0A I (earthed) - 120VAC, 60Hz none 9W (equals 60W light bulb) - II (double insulated) -

58 59 Electrical Socket - SD 035 Series

• Quickly connected • Available with or without fuse • Clip fixing

The DIN rail mounted electrical socket can be quickly fitted and connected in enclosures allowing the use of auxiliary products such as hand lamps, mea- suring devices, soldering irons etc. The unit is available with and without fuse and in many world socket standards.

Technical Data: Connection 3 x pressure clamps for stranded and rigid wire 0.5 - 2.5mm2 Mounting Clip for 35mm DIN rail, EN60715 Casing Plastic acc. to UL94 V-0, light grey Dimensions 92 x 62 x 48mm Weight Approx. 0.2kg Fitting position Variable Op/storage temp. -45 to +70°C Prot. type/prot. class IP20 / I (earthed)

Connections from mains

Art. No. Operating voltage Socket Model Nominal Current Approvals 250VAC Germany/Russia (1) with fuse* 6.3A - 250VAC Germany/Russia (1) without fuse 16.0A - 250VAC F/PL/CZ/SK (2) with fuse* 6,3A - 250VAC F/PL/CZ/SK (2) without fuse 16.0A - 250VAC Switzerland (3) with fuse* 6.3A - 250VAC Switzerland (3) without fuse 10.0A - 250VAC UK/Ireland (4) with fuse* 6.3A - 250VAC UK/Ireland (4) without fuse 13.0A - 125VAC USA/Canada (5) with fuse* 6.3A UL File No. E222026 125VAC USA/Canada (5) without fuse 15.0A UL File No. E222026 250VAC Italy (6) with fuse* 6.3A - 250VAC Italy (6) without fuse 16.0A - * fuse Ø 5x20mm

58 59 IP45/IP55 Pressure compensation Device - DA 084

• High degree of protection • Easy to install

It has become more and more important to provide a protected enclosure environment for valuable and crucial electrical and electronical components. In a tightly closed enclosure, pressure differentials can occur during extreme temperature variations, such as day/night operation. When this occurs, the risk of dust and humidity being absorbed into the control panel increases dramatically.The specially designed pressure compensation plug DA 084 per- mits a controlled change in pressure. It can be installed easily in any enclo- sure. Because of the pressure compensation plug’s high degree of protection (IP45), the protection type of the enclosure will not be affected.

Technical Data: Mounting PG29 thread with union nut Material Plastic acc. to UL94 V-0 Photo: Inside view Air interface Approx. 7cm2 Dimensions Ø65.5x30.5mm Fitting position Variable Op/storage temp. -45 to +70°C

Installation: Make cut-out Ø37+¹mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.

Art. No. Model Protection type 1 packing unit Weight (approx.) without gasket IP45 2 pieces 62g (31g/piece) with gasket IP55 2 pieces 62g (31g/piece)

60 61 IP66 Pressure compensation Device - DA 284

• High degree of protection • Semipermeable membrane • Easy to install

Pressure differentials in enclosures with a high degree of protection with respect to humidity and dust are a result of inside and outside temperature fluctuations. In case of negative pressure or vacuum, dust and humidity can be absorbed through the door seal and can enter the enclosure. As the humidity cannot exit the enclosure condensation may occur. The easy to install pressure compensation device DA 284 provides the compensation of pressure at a protection degree of IP66. A semipermeable membrane inside the plug allows air and humidity to leave the enclosure. In the opposite direc- tion, it only allows dry air into the enclosure while humidity and dust from the outside are blocked by the membrane.

Technical Data: Mounting Thread M40 x 1.5 with nut Photo: Inside view Depth in enclosure Approx. 16mm Material Plastic, light grey Sealing Sealing gasket NBR Filter Semipermeable membrane Air permeability 1200 l/h at a pressure difference of min. 70mbar Dimensions Ø60x37mm Fitting position Variable Op/storage temp. -45 to +70°C

Installation: Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.

Art. No. Protection type 1 packing unit Weight (approx.) IP66 (EN 60529) / IPX9K (EN 40050-9) 2 pieces 90g (45g/piece) IP66 (EN 60529) / IPX9K (EN 40050-9) 1 piece 45g

60 61 IP66 Pressure compensation Device - DA 284

• High degree of protection • Semipermeable membrane • Corrosion resistant • Food safe

Pressure differentials in enclosures with a high degree of protection with respect to humidity and dust are a result of inside and outside temperature fluctuations. In cas of negative pressure or vacuum, dust and humidity can be absorbed through the door seal and can enter the enclosure. As the hu- midity cannot exit the enclosure condensation may occur. The easy to install pressure compensation device DA 284 provides the compensation of pres- sure at a protection degree of IP66. A semipermeable membrane inside the plug allows air and humidity to leave the enclosure. In the opposite direction, it only allows dry air into the enclo- sure while humidity and dust from the outside are blocked by the membrane.

Photo: Inside view Technical Data: Mounting Thread M40 x 1.5 with nut Depth in enclosure Approx. 9mm Material Stainless steel V2A (DIN 1.4404 / AISI 316L) Sealing Sealing gasket NBR Filter Semipermeable membrane Air permeability 1200 l/h at a pressure difference of min. 70mbar Dimensions Ø58x31mm Fitting position Variable Op/storage temp. -45 to +70°C

Installation: Make cut-out Ø40.5+0.5mm in enclosure wall and mount pressure compensation device with nut. Please make sure that the sealing gasket is put in place on the outer side panel of the enclosure. For optimal pressure compensation we recommend to use two devices on opposite sides towards the top of the enclosure.

Art. No. Protection type 1 packing unit Weight (approx.) IP66 (EN 60529) / IPX9K (EN 40050-9) 1 piece 160g

62 63 Self-adhesive Sanofix - Appliance Holder

Sanofix is an appliance holder for direct fixing of small appliances and perfo- rated 35mm DIN rails.

With Sanofix small appliances can be mounted in switch cabinets significant- ly quicker, easier and more economically than before, without drilling holes. Mounting DIN rails is a simple matter with Sanofix. Longer rails are mounted on several Sanofix units and joining two rails is also not a problem. Subsequent changes and the mounting of additional appliances can be car- ried out with ease - even in confined spaces.

Sanofix is a self-adhesive plastic unit with an adhesion power which will bear a continuous load of 500g. The high-perfor- mance industrial adhesive band is also non-ageing and designed with safety tolerances.

Technical Data: Load 500g 24h waiting period* Mounting Self-adhesive (non-ageing, high-performance adhesive band) Material Plastic acc. to. UL94 V-0 Dimensions 43x38x14mm Screw pitch 12.8mm; Ø3.6mm, for perforated 35mm DIN rail Op./storage temperature -45 to 70˚C *Depending on the conditions of use (e.g. surface condition, size of the device to be mounted, etc.) higher loads are possible.

Installation: Sanofix can only be mounted on smooth surfaces, e.g. metals, lacquered surfaces and plastics (except poly- ethylene, polypropylene and rubber). The surfaces must be dry, free from dust, oil, separating agents and other contamination.

Application examples: SANOFIX Self-adhesive surface Protective film

Holes for screw fixing

Art. No. 1 packing unit Weight (approx.) 5 pieces 60g (12g/piece)

62 63 Calculation of temperature control in enclosures

What’s needed: 1. The dimensions of the enclosure (height, width, depth) (m) 2. The enclosure position (e.g. single enclosure, enclosure in row) according to calculation formula, enclosure surface area A (m²) 3. The enclosure material (metal, plastic) coefficient from table, k (W/m² K) 4. The temperature difference between desired enclosure interior temperature Ti (°C) and the expected ambient temperature Tu (°C) (e.g. day - night, summer - winter, climate zones) ∆T (K=Kelvin)

5. The stray power (self-warming) of all installed components during operation (e.g. transformers, relays, semiconductors) PV (W)

Calculation and selection of parameters: enclosure surface area - heat transfer coefficient - temperature difference

1. Enclosure surface area from dimensions 2. Enclosure position (plan view) acc. to VDE 0660 part 500 Formular for cabinet surface area A (m²) H = height - W = width - D = depth Single enclosure free on all sides A = 1.8 x H x (W + D) + 1.4 x W x D Single enclosure, wall mounted A = 1.4 x W x (H + D) + 1.8 x D x H First or last enclosure in free standing row A = 1.4 x D x (H + W) + 1.8 x W x H First or last enclosure in wall mounted row A = 1.4 x H x (W + D) + 1.4 x W x D Middle enclosure in free standing row A = 1.8 x W x H + 1.4 x W x D + D x H Middle enclosure in wall mounted row A = 1.4 x W x (H + D) + D x H Middle enclosure in wall mounted row with covered top A = 1.4 x W x H + 0.7 x W x D + D x H

Example.: Enclosure free on all sides, 2000mm high / 800mm wide / 600mm deep. A = 1.8 x 2.0 x (0.8 + 0.6) + 1.4 x 0.8 x 0.6 = 5.712m²

3. Enclosure material and its heat transfer coefficient k (W/m² K) 4. Temperature difference ∆T (K=Kelvin)

Steel sheet, painted k~5.5W/m² K ∆T = Ti - Tu Steel sheet, stainless k~4.5W/m² K Aluminium k~12W/m² K i.e. the temperature difference between interior and exterior Aluminium, double-walled k~4.5W/m² K temperatures. Polyester k~3.5W/m² K

Calculation formula for required heating performance (heater):

Required heating performance PH (W) = enclosure surface area A (m²) x heat transfer coefficient k (W/m² K) x temperature difference ∆T (K) Example.: W = 5.712m² x 5.5W/m² K x 15K = 471.24W Result: Heater with 500W heating performance is required. If enclosure is situated outdoors the calculated heating performance must be doubled!

HeatingVarmeyd eperformancelsesdiagram diagram Or choose required heating performance from diagram: W d e l s y

5. In case of continuous stray power PV (W) m e a r (self-warming) this must be deducted from V the calculated heating performance. Temperature difference ∆T difference Temperature Choose required cooling performance from diagram: Heating performance W Or calculate using formula for required cooling Skabets overfladeareal m2 performance (filter fan): Enclosure surface area m²

Required air volume V (8m³/h) = installed stray power Pv(W) x air constant f* (3.3m³K/Wh) temperature difference ∆T (K)

Example.: V = 600W x 3.3m³K/Wh = 132m³/h 15K ) W e k t P v ( e d n i g s f p r S

Stray power Pv (W) AirL uVolumeftmæng (m³/h)de (m3/time)

*f(0-100)=3.1m³ K/Wh, f(100-250)=3.2m³K/Wh, f(250-500)=3.3³K/Wh, f(500-750)=3.4m³K/Wh, f(750-1000)=3.5m³K/Wh

64 65 64 65 Member of the NIBE Group

• Process Heating • Heating Elements • Heating Cables • Finned Tubular Radiators • Immersion Heaters • Church Heating • Frost Protection • Ex-Material • Oilfilled Radiators • Drum Heaters • Heating Pads • Flow Heaters • Air Heaters • High-voltage • Resistors • Controllers

With more than 50 years of experience SAN Electro Heat’s most valu- able asset is special knowhow about design, product development and manufacturing of professional electrical heating equipment for industrial use.

The company is geared to deliver 100% customized products, and thus functions both as a catalyst for a development project and as supplier of the final product. At the same time we insure and maintain the required quality level, mechanical and electrical dimensioning, approvals and documentation.

Denmark, UK: Germany: Mainoffice:

Gillelejevej 30b Harold Comerford Wolfgang Biehs DK-3230 Graested [email protected] [email protected] [email protected] tel.: +44 1432 851999 tel.: +49 6171 887 724 tel.: +45 4839 8888 mobile: +44 7802 853862 mobile: +49 1622 793 484 fax: +45 4839 8898 2015 January 30th www.san-as.com