Quick viewing(Text Mode)

Exposed Rafter Eaves Detail

Exposed Rafter Eaves Detail

CONCRETE INTERLOCKING TILES ON 50x25 SW BATTENS. RECOMMENDED GAUGE ON TYVEK SUPRO BREATHER MEMBRANE. ALL TRUSSED AT MAX 600cts. CONCRETE INTERLOCKING INSULATION QUILT BETWEEN ON 50x25 SW BATTENS. RECOMMENDED TRUSSES THROUGHOUT ROOF GAUGE ON TYVEK SUPRO BREATHER SPACE & TAKEN INTO REAR OF MEMBRANE. ALL TRUSSED RAFTERS AT JABLITE INSULINK - REFER TO MAX 600cts. TYPE WORKING DRAWING FOR DEPTH INSULATION QUILT BETWEEN TRUSSES THROUGHOUT ROOF NOGGIN POSITIONED 10mm OVER SPACE & TAKEN INTO REAR OF WALLPLATE. JABLITE INSULINK - REFER TO ƒ HOUSE TYPE WORKING DRAWING FOR DEPTH

150 x 6 CONTINUOUS NOGGIN POSITIONED 10mm OVER PLY TILTING FILLET ON WALLPLATE. 400 WIDE X 6MM PLY ƒ

100mm DIA. HR PVC. 150 x 6 CONTINUOUS EAVES GUTTER. PLY TILTING FILLET ON 400 WIDE X 6MM PLY

38x38mm TREATED NOGGIN POSITIONED BETWEEN RAFTERS, TO 100mm DIA. HR PVC. TIMBER GUTTER EAVES GUTTER. COINCIDE WITH LOWER EDGE OF THE BOARD (100 X 25) RAFTERS TO SUPPORT PLASTERBOARD EBONY STAIN FINISH EDGES, NOGGIN TO BE NAIL FIXED TO SIDES OF RAFTERS. PLASTER 150 EXPOSED JUNCTIONS TO HAVE CONTINUOUS ENDS 38x38mm TREATED NOGGIN TIMBER GUTTER RIBBON OF PLASTER TO OVERCOME POSITIONED BETWEEN RAFTERS, TO BOARD (100 X 25) AIR LEAKAGE. 100 x 50 mm SW COINCIDE WITH LOWER EDGE OF THE EBONY STAIN FINISH WALLPLATE ON RAFTERS TO SUPPORT PLASTERBOARD MORTAR BED CEILING EDGES, NOGGIN TO BE NAIL 150 EXPOSED RAFTER INSULATED LINTEL STRAPPED AT MAX 300 FIXED TO SIDES OF RAFTERS. PLASTER ENDS 2000mm CTS WITH 30 x JUNCTIONS TO HAVE CONTINUOUS 40 DEG. PITCH 5 GALV. MS STRAPS. 100 x 50 mm SW RIBBON OF PLASTER TO OVERCOME WALLPLATE ON AIR LEAKAGE. MORTAR BED CONCRETE INTERLOCKING ROOF TILES STRAPPED AT MAX ON 50x25 SW BATTENS. RECOMMENDED 2000mm CTS WITH 30 x GAUGE ON TYVEK SUPRO BREATHER 5 GALV. MS STRAPS. MEMBRANE. ALL TRUSSED RAFTERS AT INSULATED LINTEL MAX 600cts. INSULATION QUILT BETWEEN 50 DEG. PITCH TRUSSES THROUGHOUT ROOF 300 SPACE & TAKEN INTO REAR OF JABLITE INSULINK - REFER TO HOUSE TYPE WORKING DRAWING FOR DEPTH NOGGIN POSITIONED 10mm OVER WALLPLATE. ƒ

150 x 6 CONTINUOUS PLY TILTING FILLET ON 400 WIDE X 6MM PLY

100mm DIA. HR PVC. EAVES GUTTER.

38x38mm TREATED NOGGIN TIMBER GUTTER POSITIONED BETWEEN RAFTERS, TO BOARD (100 X 25) COINCIDE WITH LOWER EDGE OF THE EBONY STAIN FINISH RAFTERS TO SUPPORT PLASTERBOARD CEILING EDGES, NOGGIN TO BE NAIL 150 EXPOSED RAFTER FIXED TO SIDES OF RAFTERS. PLASTER ENDS JUNCTIONS TO HAVE CONTINUOUS 100 x 50 mm SW REFER TO WORKING DRAWING MILTON AVENUE, CLITHEROE RIBBON OF PLASTER TO OVERCOME WALLPLATE ON AIR LEAKAGE. MORTAR BED FOR TRUSS VARIATIONS STRAPPED AT MAX INSULATED LINTEL 2000mm CTS WITH 30 x PLEASE REFER TO ACCREDITED DETAILS FOR 5 GALV. MS STRAPS. RAFTER EAVES DETAILS 35 DEG. PITCH 300 REDUCING AIR PERMEABILITY

02/12/16 RDL 1:20 N286/DET/001