Swimming Catalog
Total Page:16
File Type:pdf, Size:1020Kb
THE SPORTS TIMING EXPERTS Aquatic Sports SWIMMING ased on years of experience in ming the most different design and processing only high-quality materials, ALGE-TIMING Bsports, ALGE-TIMING has developed selected soluons for guarantees reliable results and above average operang me of ming all kinds of swimming compeons. Thanks to the tough the system. 2 www.alge-timing.com SWIMMING Semi-Automatic Timing System he Semi-Automac Timing System is used at lower level Timing Systems. ALGE-TIMING offers two different semi- Tcompeons for swimming. It is easy to setup and to automac systems, one is wired and the other is a radio system. operate. Of course the price is as well much lower than Automac Cable System Radio System ALGE-TIMING 1 7 6 ALGE-TIMING 2 6 1 5 5 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 4 2 4 3 3 1 timing device Timy3 WP 1 timing device Timy3 WP 2 speaker system BANG2 2 speaker system BANG2 3 radio headset BANG-HS 3 radio headset BANG-HS 4 start push buon 023-10 4 radio startgun e-Start W 5 finish push buon 023-02 5 radio push buon WTN-PB for finish 6 display board D-LINE (Time) 6 display board D-LINE (time) 7 connecon cable for 8 lanes MC8-S2 7 radio data receiver for display board WTN-DB semi-automac ming system is a system with manual finish LGE-TIMING offers a wireless, semi-automac ming system Atriggering. Each lane is equipped with one push buon with Awith one push buon WTN-PB for each lane. Each push its own ming channel. The push buons are connected via buon has its own ming channel and is equipped with the ALGE- MC8-S2 cable. The start signal is given on the speaker BANG2. TIMING Wireless Timing Network. This allows wireless ming for up to eight lanes. A display board can be connected at the ming The cabling for the system is configured as needed. The picture below shows device Timy3 WP. the cabling for a pool with 8 lanes (MC8-S2). The complete system is very flexible and the setup is very fast, since it does not need cables. www.alge-timing.com 3 SWIMMING Fully Automatic Timing System he fully automac SwimTime system is equipped with essenals and execute the events without stress. The shown Tadvanced technology that intelligently supports the system is used for large events. Depending on the budget, mekeeper. Thus, the mekeeper can concentrate on the components c an be reduced or deleted. 14 15 Lane 9 11 12 13 9 8 7 6 5 4 3 2 1 0 1 10 2 20 3 Timing Room 18 19 1 87 8 2 6 5 4 3 17 9 8 7 6 5 4 3 2 1 0 8 16 16 16 16 1 elect. startgun e-Start 6 PC for ming 11 push buon 023-02 16 video backup OPTIc3 2 start unit SU3 7 PC for meet management 12 starng block SO5 17 PC for video backup 3 flash XL 8 switch with POE+ 13 backstroke start aid BSA 18 PC for video wall 4 ming device TM-SWIM 9 swim terminal SWT3 14 speaker acve SPA 19 video wall controller 5 printer P6-8 10 touchpad TP2400C 15 speaker passive SPP 20 video wall for results 4 www.alge-timing.com SWIMMING Fully Automatic Timing System SwimTime with TimeManager TM-SWIM New technologies turn ming into pleasure. The TM-SWIM was especially designed for the extreme demands TM-SWIM. The computer is only necessary for registering a in aquac sports. The TimeManager has an integrated audio compeon in the system. The PC is also used for visualizing and amplifier and a backup baery. It combines know-how, modern controlling the TimeManager. The TM-SWIM executes the heat electronics and the solid ALGE-TIMING design. automacally and at the same me sends the mes to the SwimTime PC soware. Thus, the user can follow the compeon All ming funcons are executed and stored directly in the on the easy-to-use operang environment. Facts of the ALGE-TIMING SwimTime Timing System • PC based ming system • voice communicaon between starter and mekeeper via • USB interface headset • user-friendly handling • false start warning on display • control of up to 16 lanes at both sides • warning for too large a me difference between manual • visual and acouscal control of all lanes ming and touchpad • connecons for 1 touchpad, 3 push buons and 1 starng • warning for unregistered touches plaorm per lane (5 independent ming channels per lane • fail-safe and robust touchpads and side) • registering stascal data such as: reacon me, block-off • integrated baery backup, works for 4 hours independently me, duraon of pressure to starng plaorm and touchpads from power supply and PC • conformity: FINA, SSCH, AAU, NCAA and LEN rules • integrated amplifier system www.alge-timing.com 5 SWIMMING Fully Automatic Timing System Technical Data Measuring range: 23 hours, 59 minutes, 59.9999 seconds Time reference: TCXO 10,000 MHz (temperature compensated crystal oscillator) Precision: +/- 0.1 ppm (0.00036 s/h) Temperature range: -25 °C to +50 °C Power supply: internal: 12 V gel-cell rechargeable baery external: 100 - 240 VAC, 50/60 Hz, oponal 12 - 18 VDC Interfaces: USB interface for PC or video RS232 interface for PC or video 2 x RS232 interface for log printer 2 x RS232 interface for display board RS485 for display board Further connecons: 2 x ming bus start and turn side 2 x speaker acve 2 x SU3 (start unit) / FLASH XL start (banana jack) audio line in audio line out Volume control: microphone headset audio in total volume SWIM Terminal SWT3 Each lane and side needs one Swim Terminal. All SWT3 are idencal and not internally numbered. On switching on, the TM-SWIM automacally recognizes how many lanes are connected to the system and numbers them according to this input. Each Swim Terminal has five independent channels: • 1 x touchpad • 3 x push buon • 1 x relay take-off sensor Log Printer P6-8 online log of all pulses • compeon and heat number • compeon name • mes (start, starng plaorm, touchpads, push buon) • mes outside a heat are printed in me of day format • prinng speed: 5 lines per second 6 www.alge-timing.com SWIMMING Fully Automatic Timing System SwimTime with TimeManager TM-SWIM PC soware The ALGE-TIMING PC soware SwimTime clearly manages all office (heat classificaon, list prinng etc.) are being carried out mes and possesses opmal interfaces to all established on one or more further PCs. evaluaon soware in swimming. By dividing the soware into ming and evaluaon program (meet management soware), SwimTime is compable with all current Microso Windows ver- the ming can be executed on one PC while the tasks of the race sions (Windows XP, Vista, Windows 7, Windows 8 or Windows 10). 1 2 7 3 8 4 9 10 5 11 12 13 6 1 menu bar 5 lane number 9 manual me 12 lane with swimmer who did not start 2 compeon selecon 6 status line 10 touches 13 free lane 3 parpiant data 7 lap me 11 reacon me start side 4 reacon me turn side 8 total me The ming soware works with clear, animated symbols. This simplifies the operaon. • coordinated with the evaluaon • visualizaon • simple operaon • free soware updates • baery backup • clear logs • expandable to 16 lanes • parcipants’ data visible during timing • many helpful monitoring funcons www.alge-timing.com 7 SWIMMING Touchpads TP2400C and TP1890C he complete timing for swimming wherever the swimmers touchs, it is Moreover, every touchpad has hundreds Tdepends on the reliability of the perfectly triggered. It complies with the of small holes that allow the water to flow touchpad TP. The touchpad must with- rules of FINA, SSCH, AAU, NCAA and LEN. through and produce optimal water stand the aggressive conditions in the pool. current conditions for all lanes. ALGE-TIMING forms a solid frame from The innovative and patented touchpads stainless steel around the touchpad. This exhibit a surface from pluggable lamellas By applying new materials and a stainless protects the integrated tape switches from which guarantee exemplary slip resistan- steel casing with holes on the back side, damage and optimizes the touchpad for ce for the swimmers. Many experiments the weight of the touchpads was reduced operation in the swimming pool. and tests were executed with different by about 30 % compared to previous materials to reach such an ideal result. ALGE-TIMING touchpad models. The four tape switches are situated over The ALGE-TIMING touchpad with small the complete length of the touchpad. So nubs provides for the desired grip. All advantages at a glance: • special an -slip surface for opmal grip • four tape switches for constant and safe triggering • no faulty pulses by splash water or waves • patented water flow-through during the compeon provides for fair condions • casing from stainless steel 1.4404 • solid construcon • simple banana plug connecon with ming system • compable with most of the ming systems (NOC) • two standard models (TP2400C / TP1890C) • customer-specific dimensions on request • special transport cart for storing up to 12 touchpads • complies with: FINA, SSCH, AAU, NCAA and LEN rules 8 www.alge-timing.com SWIMMING Touchpads TP2400C and TP1890C stainless steel rear plate protects the touchpad from Adamage (high-quality stainless steel for applicaon in swimming pools). The secret of the unrivaled slip resistance is the special lamella design by ALGE-TIMING. The lamella has a rough surface with thousands of ny nubs.