BUS DUCT LS Cable Bus Duct System BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지3 BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지2 LSC BUS DUCT LS Cable Bus Duct System BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지3 LSC Bus Duct SYSTEM 1. INTRODUCTION 3 1.1 GENERAL SPECIFICATIONS 1.2 OUTSTANDING FEATURE OF LSC BUS DUCT 1.3 CATALOGING 2. HIGH POWER DISTRIBUTION (600A~6000A) 9 2.1 GENERAL SPECIFICATIONS 2.1.1 I-SERIES BUS DUCT 2.1.2 8-SERIES BUS DUCT 2.1.3 F-SERIES BUS DUCT 2.1.4 Y-SERIES BUS DUCT 2.2 GROUNDING & IP DEGREE 2.2.1 GROUNDING 2.2.2 IP DEGREE 2.3 PART DIMENSIONS 2.3.1 SECTIONAL DIMENSIONS 2.3.2 FLANGED END DIMENSIONS 2.3.3 PHYSICAL DATA FOR FITTINGS 2.4 BRANCH METHOD 2.5 TECHNICAL DATA 2.6 MAINTENANCE 3. MEDIUM POWER DISTRIBUTION (100A~400A) 45 3.1 M-SERIES (MINI BUS DUCT) 3.2 B-SERIES (BABY BUS DUCT) 4. AIR INSULATED BUS DUCT 51 4.1 A-SERIES (LOW VOLTAGE) 4.2 H-SERIES (HIGH VOLTAGE) BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지4 1. INTRODUCTION 1.1 GENERAL SPECIFICATIONS 1.2 OUTSTANDING FEATURE OF LSC BUS DUCT 1.3 CATALOGING BUS DUCT which has non-corrosive conductor covered by non-flammable insulator inside of steel housing for protection is an electrical distribution system made rapid progress and growth recently as the most optimized option with flexibility and lower losses for massive power delivery in high rise commercial building and industrial plant. BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지4 1.1 General Specifications BUS DUCT, A Power Distribution System of High Stability & Easy Maintenance When electrical power became widely used in industry, a need was created for a rational energy carrying and distribution system to supply the machineries with electricity. Basically, LSC Bus Duct has been designed, manufactured, and provided in the following conditions. Suitable to Mass-Current Bus Bar LSC Bus Duct system which can carry massive power Copper bus bar has conductivity of 99% or more, or upto 6000A with lower losses is used as distribution Aluminum bus bar has conductivity of 61% or more. system for main line according to needs of high-rise Plating between contact sections of conductors are; building and factory plant through the features of flexibility, safety, reliability, economical efficiency and Cu conductor : Tin-Plated improved demerits of cable epochally. Al conductor : Silver-Plated LSC Bus Duct system is simplified so that load may be This plating improves the contact resistance and prevents freely diverged, extending, moving, replacing and electrical corrosion. maintenance of the load easily. Temperature Rise Property Meanwhile, this has a fine view harmonized with modern architectural sense. Temperature rise shall be within 55˚C in the joint part of conductor and 40˚C or less in the external surface of duct, under an ambient temperature of 40˚C or less. Service Conditions Insulation Ambient temperature : -15˚C~40˚C Multi-Layer polyester films of class B(130˚C) shall be Relative Humidity : 95% or below applied into thickness 0.5mm on conductor. Installation Attitude : Maximum 1000M above sea level BMC forms which is polyester reinforced by glass fiber shall be applied as a spacer between conductors of joint Standards part or conductor and duct. KSC 8450: Bus ways JISC 8364: BUS DUCT FR-Insulation IEC 60439-1&2: Bus ways Multi-Layer of Fire Resistant Insulator(1200˚C) shall be BSEN 60439: Bus ways applied on conductor. 4 5 BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지5 1.2 Outstanding Feature of LSC Bus Duct Benefits of LSC Bus Duct over wire and conduit LSC Bus Duct System can improve installation area and cost with the compact size in a big jump. Labor Savings Lower Voltage Drop LSC Bus Duct installation is faster when compared to Because of its extremely low reactance, LSC Bus Duct other method of low voltage power distribution. While voltage drop is low. This efficient design allow power to material costs may be slightly higher, the labors be delivered in an installation with the highest efficiency required to install LSC Bus Duct is often much lower. possible. This makes LSC Bus Duct ideal for efficient power distribution in commercial or industrial facilities. This results in an overall reduction in total installation cost. Easy to Install Compact Size LSC Bus Duct incorporates the “one joint bolt type”. For connection work, bolt fastening forces were unified into LSC Bus Duct requires less space than wire and the torque of 1200kg.cm. conduit. 1. Set the center line and level together 2. Fit together till the duct joiners touch 3. Tighten the “MF” nut by special ratchet the stoppers. wrench till the neck part of nut is broken and locked. 4. Attach the joint cover with M6 bolt & nut. 5. Completion of joint. Better Transmission Efficiency. Future Expansion Flexibility. High Short-Circuit Ratings. SAFETY POINT: Nut (1) shall be neither taken off, nor dropped. when neck (2) is broken, twisting force remains. Harmonized View. ➞ BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지6 1.3 Cataloging LSC BUS DUCT CODING Table 6 LSC VOLTAGE SHAPE CURRENTS FIRE BRANCH I P Grade GROUNDING BUS DUCT RANGE STRUCTURE RANGE RESISTANCE LIMITS (41.54.65) TYPE IG41 GENERAL IG TYPE IG54 IG65 I-SERIES IP41 PE EARTH IP TYPE IP54 TO 400A IP65 WITHOUT IH41 POWER HALF EARTH IH TYPE IH54 SHUTDOWN IH65 IF41 FULL EARTH IF TYPE IF54 GENERAL IF65 TYPE 8G41 GENERAL 8G TYPE 8G54 COMPACT 8G65 TYPE 8-SERIES 8P41 PE EARTH 8P TYPE 8P54 TO 800A 8P65 WITHOUT 8H41 POWER HALF EARTH 8H TYPE 8H54 BELOW SHUTDOWN 8H65 600V 8F41 FULL EARTH 8F TYPE 8F54 8F65 600A~6000A FG41 GENERAL FG TYPE FG54 FG65 F-SERIES FP41 PE EARTH FP TYPE FP54 TO 400A FP65 WITHOUT FH41 POWER HALF EARTH FH TYPE FH54 LSC SHUTDOWN FH65 BUS DUCT FF41 SYSTEM FIRE FULL EARTH FF TYPE FF54 RESISTANCE FF65 TYPE YG41 GENERAL YG TYPE YG54 YG65 Y-SERIES YP41 PE EARTH YP TYPE YP54 TO 800A YP65 WITHOUT YH41 POWER HALF EARTH YH TYPE YH54 SHUTDOWN YH65 YF41 FULL EARTH YF TYPE YF54 YF65 MP41 200A~400A M-SERIES Mini MP54 MP65 BP41 100A~200A B-SERIES PE EARTH Baby BP54 BP65 AIR LP41 INSULATED BELOW 100A L-SERIES Lighting LP54 TYPE LP65 GENERAL AP41 TYPE Low A-SERIES PE EARTH Voltage AP54 AP65 600A~4000A HP41 OVER High H-SERIES HP54 600V PE EARTH Voltage HP65 EACH TYPE OF BUS DUCT CAN BE SUPPLIED as IP DEGREE IP41~IP66 6 7 BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지7 BUS DUCT SYSTEM Building 3F END CLOSER SPRING VERTICAL HANGER FLANGED END VERTICAL 2F ELBOW EXPANSION JOINT FLATWISE RIGID VERTICAL HANGER FLANGED HANGER END HORIZONTAL TEE PLUG IN HOLE 1F PLUG IN UNIT REDUCER RIGID VERTICAL HANGER HORIZONTAL HORIZONTAL MEDIUM ELBOW OFF-SET BASE CHANNEL HANGER FEED IN BOX FLANGED VERTICAL END BOX TEE EDGEWISE TR END FLANGED HANGER END BOX Transformer B1 CABLE TRAY SWTCHGEAR BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지8 BUS DUCT SYSTEM Factory FLANDED END BOX Insulated Bus Duct VERTICAL ELBOW Indoor HORIZONTAL ELBOW Outdoor PLUG IN MINI BUS DUCT Insulated Bus Duct 3.3KV 3P 3W 1200A(Cu-Fe) High Voltage Bus Duct EDGEWISE HANGER Feed in Box TR END FLANGED HORIZONTAL Transformer OFF-SET Cable H.V FLANGED END SWITCHGEAR PLUG IN HOLE L.V SWITCHGEAR PLUG IN MINI BUS DUCT END CLOSER PLUG IN BABY BUS DUCT PLUG IN BOX 8 9 BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지9 2. HIGH POWER DISTRIBUTION (600A~6000A) 2.1 GENERAL SPECIFICATIONS 2.1.1 I-SERIES BUS DUCT 2.1.2 8-SERIES BUS DUCT 2.1.3 F-SERIES 2.1.4 Y-SERIES 2.2 GROUNDING & IP DEGREE 2.2.1 GROUNDING 2.2.2 IP DEGREE 2.3 PART DIMENSIONS 2.3.1 SECTIONAL DIMENSIONS 2.3.2 FLANGED END DIMENSIONS 2.3.3 PHYSICAL DATA FOR FITTINGS 2.4 BRANCH METHOD 2.5 TECHNICAL DATA 2.6 MAINTENANCE BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지10 2.1 General Specifications 2.1.1 I-Series Bus Duct I-Series (Insulated Bus Duct) is a totally enclosed non-ventilated and sandwitch type bus duct system for 110, 220, 380, 440 and 600V power distribution. This is designed for indoor and drip-proof use and available from 600 to 6000A. The load branch of this I-Series are by plug-in unit upto 400A and by Tap-off unit over 400A. There are one bar, two bars and three bars per phase according to Ampacity. Fastening Bolt & Washer Reinforcement Band for Reducing Hysteresis & Eddy Current Loss and Reinforcing Short Circuit Capacity Steel Duct Coated with Paint Four Layer Polyester Film of Class B(130˚C) Copper or Aluminum R.Head Bolt High Tension Joint Bolt Disk Spring(C) Stopper(D) Joint Cover Cross Head Driver Bolt & Washer Insulation Spacer(B) Contact Surface(A) Housing (A) Contact Surface Connection Silver-Plated for Aluminum Tin-Plated for Copper. (B) Insulation Spacer Polyester Resin BMC. (C) Disk Spring (Belleville Washer) Joint Cover Absorbs the Expansion & Contraction of Joint Parts. (D) Stopper Square Nut Regulates the Length of Conductor Lapping. (E) Captive Hardware Anti-Rotation Fitting for Fastening High Tension Joint Bolt. “I”- Series Bus Duct have Four Types according to Grounding Conductor. Table 10 OPTION TYPE OPTION 1 OPTION 2 OPTION 3 OPTION 4 Grounding Option Code : IG TYPE Code : IP TYPE Code : IH TYPE Code : IF TYPE Code : IG41 TYPE Code : IP41 TYPE Code : IH41 TYPE Code : IF41 TYPE IP Grade Option Code : IG54 TYPE Code : IP54 TYPE Code : IH54 TYPE Code : IF54 TYPE Code : IG65 TYPE Code : IP65 TYPE Code : IH65 TYPE Code : IF65 TYPE Integral housing system Integral housing & External Integral Half Earth bus Integral Full Earth bus Description Earth bus bar system bar system bar system 10 11 BUSDUCT최종(P) 2006.2.13 1:33 PM 페이지11 2.1.2 8-Series “8”-Series(Plug-in 800A Bus Duct) has same all characteristics as I-Series.
Recommended publications
  • DIV-16 Electrical Labor
    Division 16 Electrical Estimating Tips General 163 Motors, Starters, Boards & Estimators for this division item shall have full Switches knowledge of the system and working knowledge Estimator shall include all supporting systems used, prepare a complete take-off quantities, for these items, whether it is a foundation, code requirements, specifications, and bracket or a piece of wood. SCECO requirements. 164 Transformers & Bus Ducts 160 Raceways Never forget to include the equipment cost for Conduit should be taken off in three main such installation, whether scaffolding, lifts or categories: power distribution, branch power, cranes. and branch lighting, so the estimator can concentrate on systems and components, 165 Lighting therefore making it easier to ensure all items Productivity rate for lighting fixtures varies with have been accounted for. For cost modifications the number of fixtures included in a single room. for elevated conduit installation, add the Estimators are advised to increase productivity percentage to labor according to the height of rate of lighting fixtures in large rooms including installation for all and only the quantities more than six (6) fixtures. exceeding the different height levels and number of building floors. 168 Special Electrical System Usually most of these systems are let to 161 Conductors & Grounding specialized contractors, provisions for special Remember that aluminum wiring of equal installation requirements shall be consulted. capacity is larger in diameter than copper and may require larger conduit. If more than three 169 Utilities wires at a time are being pulled, deduct Usually these items are let to specialty percentages from the labor hours of that contractors, whether for transmission lines and grouping of wires.
    [Show full text]
  • Pow-R-Way III Busway Design Guide
    Design Guide DG017002EN Effective February 2020 Low-voltage power distribution and control systems > Busway > Low-voltage busway—Pow-R-Way III Contents General Description . 24 .1-2 Overview .................................. 24.1-2 Standards .................................. 24.1-2 Construction Details .......................... 24.1-3 Fittings . 24 .1-8 Fittings .................................... 24.1-8 Elbows .................................... 24.1-9 Flanges .................................... 24.1-12 Offsets .................................... 24.1-14 Tees ...................................... 24.1-16 Crosses ................................... 24.1-17 Tap Boxes ................................. 24.1-18 Weatherheads .............................. 24.1-20 Expansion Joints ............................ 24.1-21 Phase Transpositions ......................... 24.1-21 Transformer Taps ............................ 24.1-22 Transformer Throat Connections ................ 24.1-23 Reducers .................................. 24.1-24 Meter Center Power Takeoffs .................. 24.1-25 Busway-Connected Panelboards ................ 24.1-28 Pow-R-Way III Adapters ....................... 24.1-29 Wall/Floor/Roof Flanges and End Closers ......... 24.1-30 Hangers ................................... 24.1-31 Devices . 24 .1-33 Plug-In Protective Devices ..................... 24.1-33 Surge Protective Device (SPD) Plug-In Devices ..... 24.1-35 Power Takeoffs ............................. 24.1-38 Receptacle Plug-In Devices .................... 24.1-39
    [Show full text]
  • Design, Construction and Simulation of a Circuit- Breaker Based Feeder
    ISSN: 2277-3754 ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 2, August 2014 Design, Construction and Simulation of a Circuit- Breaker Based Feeder Pillar with over current And Earth-Fault Protection Cum Digitalized Voltmeter Azuatalam D.T., Diala U.H., Iwuchukwu U.C., Joe-Uzuegbu C.K., Morah F.C. and Ayalogu E.I. Dept. of Electrical and Electronic Engineering, Federal University of Technology Owerri, Imo State, Nigeria Abstract -This research embodies the design, construction three-phase in case there is a phase failure in the and simulation of a feeder pillar (415VAC) with over-current, system.The design of the feeder is done in such a way overload and earth-fault protection with the aid of a phase that restoring of power after fault has occurred will be sequence relay, contactor, earth-leakage circuit breaker and easy such that after fault is cleared, breakers can be put in three-phase overload relay. The analog voltmeters in the normal position to restore power. Also, the system is various bus-bars (red, yellow and blue phases) in a conventional feeder pillar is replaced with a digital panel designed in such a way that there will be easy voltmeter indicating the voltage across a phase (240V) or line- discrimination. After the source, the bus bar is connected to-line (415VAC) flowing through the bus-bars. The major next, then the contactor controlled by a switch.The reason for this research study is to prevent the constant contactor feeds the phase monitor and three-pole circuit changing of fuses.
    [Show full text]
  • Low and Medium Voltage Bus Duct Types LX and MX Types LX and MX Bus Duct
    Low and Medium Voltage Bus Duct Types LX and MX Types LX and MX Bus Duct APPLICATION Growing emphasis on the reliability of electrical power Type LX and type MX bus duct systems are suitable for systems for industrial and commercial facilities has installation in almost any environment. Bus duct is inher- resulted in increased demand for both low and medium ently resistant to many of the forces or conditions which voltage metal enclosed bus duct. M&I Electric Industries, accelerate the deterioration of insulated cable in conduit Inc. type LX (low voltage) and type MX (medium voltage) or tray. As a major added benefit, bus duct is often less bus duct provides a solution to this demand. expensive than equivalent cable installations. Types LX and MX bus duct systems are reliable, afford- M&I can supply special assemblies of types LX and MX able, and are readily available. Like all M&I products, LX bus duct on extremely short notice to meet emergency and MX bus duct systems benefit from M&I’s commitment (burn-out) requirements. to consistently exceed customer quality and availability expectations. M&I types LX and MX bus duct is commonly used for: M&I types LX and MX bus duct can be supplied in a wide · Main service entrance bus. range of ratings, arrangements, designs, materials, and enclosure types. This range of products has been · Switchgear main bus interconnections. designed to meet the electrical and physical requirements of virtually any electrical power system or equipment · Connections between transformers and switchgear. installation. RATINGS Nominal Voltage Continuous Dry Withstand Dew Withstand Impulse Voltage Short-Circuit Rating Current Rating Voltage Rating Voltage Rating Rating Current Rating 1200 Amperes 2000 Amperes 600 Volts 2.2 kV N/A N/A 100 kA 3000 Amperes 4000 Amperes 1200 Amperes 2000 Amperes 58 kA 5 kV 19.0 kV 15.0 kV 60 kV BIL 3000 Amperes 78 kA 4000 Amperes 1200 Amperes 2000 Amperes 58 kA 15 kV 36.0 kV 24 kV 95 kV BIL 78 kA 3000 Amperes 4000 Amperes The ratings above are for standard bus duct in accordance with ANSI standard C37.23 1987.
    [Show full text]
  • Powervac Switchgear Application Guide
    Power/Vac® Product Family Application Guide Intentionally left blank Application Guide Power/Vac® Metalclad Switchgear And Related Products Power/Vac® is a registered trademark of Powell Industries Inc., Houston, Texas. Information contained in this Application Guide is based on established industry standards and practices. It is published in the interest of assisting power system planners and engineers in the preparation of their plans and specifications for medium-voltage metalclad switchgear. Neither Powell Electrical nor any person acting on its behalf assumes any liability with respect to the use of, or for damages or injury resulting from the use of any information contained in this Application Guide. The information in this guide does not supplement or replace performance data contained in other product publications of the Company. The Com- pany reserves the right, at its discretion, to change material or design without prior notification. Sections Power/Vac® Switchgear Concepts And Basic Configurations 1 Creating System One-Line Diagrams 2 Circuit Breaker Ratings and Selection 3 Control Power Considerations 4 System and Equipment Protection 5 Power/Vac® Switchgear Equipment Applications 6 Standard Power/Vac® Construction Features and Installation Information 7 Ground and Test Device, Dummy Breaker 8 Intentionally left blank ContentsSection 1 Section 1 Power/Vac® Switchgear Concepts And Basic Configurations Page USE OF APPLICATION GUIDE.......................................................................... 1-2 Power/Vac® METALCLAD
    [Show full text]
  • Westinghouse AP1000 Design Control Document Rev. 16
    8. Electric Power AP1000 Design Control Document 8.3 Onsite Power Systems 8.3.1 AC Power Systems 8.3.1.1 Description The onsite ac power system is a non-Class 1E system comprised of a normal, preferred, maintenance and standby power supplies. The normal, preferred, and maintenance power supplies are included in the main ac power system. The standby power is included in the onsite standby power system. The Class 1E and non-Class 1E 208/120 Vac instrumentation power supplies are described in subsection 8.3.2 as a part of uninterruptible power supply in the dc power systems. 8.3.1.1.1 Onsite AC Power System The main ac power system is a non-Class 1E system and does not perform any safety-related functions. It has nominal bus voltage ratings of 6.9 kV, 480 V, 277 V, 208 V, and 120 V. Figure 8.3.1-1 shows the main generator, transformers, feeders, buses, and their connections. The ratings of major ac equipment are listed in Table 8.3.1-3. During power generation mode, the turbine generator normally supplies electric power to the plant auxiliary loads through the unit auxiliary transformers. The plant is designed to sustain a load rejection from 100 percent power with the turbine generator continuing stable operation while supplying the plant house loads. The load rejection feature does not perform any safety function. During plant startup, shutdown, and maintenance the generator breaker remains open. The main ac power is provided by the preferred power supply from the high-voltage switchyard (switchyard voltage is site-specific) through the plant main stepup transformers and two unit auxiliary transformers.
    [Show full text]
  • Non-Segregated Phase Bus Duct Design Guide
    Design Guide DG017001EN Effective July 2020 Low-voltage power distribution and control systems > Busway > Busway—medium voltage Contents General Description . 11 .1-2 Overview .................................. 11.1-2 Standards .................................. 11.1-2 Construction Details ......................... 11.1-4 Fittings . 11 .1-8 Traditional Elbows ........................... 11.1-8 Offsets .................................... 11.1-9 Tees ...................................... 11.1-10 Switchgear Flanges .......................... 11.1-11 End Cable Tap Box ........................... 11.1-12 Phase Transposition .......................... 11.1-12 Expansion Joints ............................ 11.1-13 Bushing Box Termination ...................... 11.1-13 Transformer Termination ....................... 11.1-14 Sealing Ring ................................ 11.1-14 Vapor Barriers ............................... 11.1-15 Fire Barriers ................................ 11.1-15 Column Supports ............................ 11.1-16 Horizontal Hanger ........................... 11.1-17 Wall/Floor Flange ............................ 11.1-19 Devices . 11 .1-20 Space Heaters .............................. 11.1-20 Layout . 11 .1-21 Installation Diagrams ......................... 11.1-21 Field Fit ................................... 11.1-22 Application Data . 11 .1-24 Electrical Data .............................. 11.1-24 Physical Data ............................... 11.1-25 More about this product Eaton.com/busway Complete library of design guides
    [Show full text]
  • WL Low Voltage Metal-Enclosed Switchgear
    WL Low Voltage Metal-Enclosed Switchgear Selection and Application Guide usa.siemens.com/switchgear Type WL Low Voltage Metal-Enclosed Switchgear Table of Contents General Information 2 Construction Details 3-5 WL Circuit Breaker 6-8 Electronic Trip Unit 9-15 Breaker Technical Data 16-17 WL Secondary Terminal Assisgnments 18 Section Configurations 19-20 Shipping Weights and Dimensional Information 21-29 VT, CPT, CT Data 30 1 Type WL Low Voltage Metal-Enclosed Switchgear General Information Siemens Type WL low voltage metal- enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of the Type WL low voltage switchgear is the World Class Siemens WL breaker. Siemens Type WL low voltage switchgear can be utilized in the following applications: • Industrial Heavy assembly Semiconductor Petrochemical Automotive Biotech Pharmaceutical • Institutional Type WL Low Voltage Metal-Enclosed Switchgear Water treatment Airports Industry Standards Universities • ANSI C37.17 – Trip Devices for AC Type WL switchgear with power circuit Medical facilities and General Purpose DC Low-Voltage breakers are designed, tested and Correctional facilities Power Circuit Breakers constructed in accordance with: • NEMA SG3 - Low Voltage Power • Critical Power • UL 1558 – Metal-Enclosed Low Circuit Breakers Data Processing Voltage Power Circuit Breaker Continuous industrial process Switchgear Features and modifications required by Hospitals • ANSI C37.20.1 – Metal-Enclosed NEC are incorporated
    [Show full text]
  • LECTRO Bus Way System [Series LSB II / 300A - 6400A] LECTRO Bus Way System [Series LSB II/ 300A - 6400A] Energy Demand Is Ever Growing
    LECTRO Bus Way System [Series LSB II / 300A - 6400A] LECTRO Bus Way System [Series LSB II/ 300A - 6400A] Energy demand is ever growing... we attempt to provide efficient distribution of electrical power with minimum power loss Contents Introduction .......................... 05 Busducts advantages , applications ... 06 LECTRO BAR Series LSB II Features .......................... 08 Design, Construction .............. 10 Types .......................... 12 Innovations .......................... 14 Accessories .......................... 16 Data Sheet .......................... 29 Qualification .......................... 30 04 Introduction Introduction Busducts Since 1980, Lectrobar has manufactured and installed thousands of meters of bus ducts. State of the art ISO certified manufacturing facility has their products type tested by KEMA of Netherlands. Lectrobar busducts are trusted for their high safety factor & long life span. Lectrobar presents “Series LSB II” bus bar risers ranging from 300A upto 6400A. Features Design Types Innovations Accessories Data Sheet Qualification At Lectrobar, you - the client, is the purpose for our pursuit of growth and most importantly, perfection. Thank you for choosing us to partner your journey in creating effective, efficient and sustainable power solutions. 05 Busducts Advantages of busbar )OH[LELOLW\ (IÀFLHQF\ Less space over cables reusable, expandable Cost savings Tapoffs make supply to addi- Half the man-hours: thanks to the sandwich de- tional loads easy at anytime Installation requires only half
    [Show full text]
  • Specification N0
    NORTHERN INDIANA COMMUTER TRANSPORTATION DISTRICT TRACTION POWER REHABLITATION SPECIFICATION FOR MADISON SUBSTATION PREPARED FOR NICTD BY: LARAMORE, DOUGLASS & POPHAM, INC. Consulting Engineers 20N. Wacker Drive, Suite: 1500 Chicago, IL 60606 DISTRICT NORTHERN INDIANA COMMUTER TRANSPORTATION DISTRICT MADISON SUBSTATION REHABLITATION TABLE OF CONTENTS EXHIBIT 1 DRAWINGS AND TECHNICAL SPECIFICATION DIVISION 1 – GENERAL PAGES SECTION 01010 SUMMARY OF WORK 01010-1 THRU 01010-9 SECTION 01011 DRAWING LIST 01011-1 THRU 01011-2 SECTION 01012 WORK SEQUENCE AND CONSTRAINTS 01012-1 THRU 01012-3 SECTION 01027: SCHEDULE OF VALUES 01027-1 THRU 01027-2 SECTION 01300: SUBMITTALS 01300-1 THRU 01300-10 SECTION 01310: PROGRESS SCHEDULE AND REPORTS 01310-1 THRU 01310-5 SECTION 01700: PROJECT CLOSEOUT 01700-1 THRU 01700-4 DIVISION 16 – ELECTRIAL SECTION 16010: GENERAL PROVISIONS ELECTRICAL 16010-1 THRU 16010-3 SECTION: 16011: BASIC ELECTRICAL MATERIALS AND METHODS 16011-1 THRU 16011-12 SECTION 16125: TRACTION POWER CABLES 16125-1 THRU 16125-12 SECTION 16126: TRACTION POWER CABLE LUGS 16126-1 THRU 16126-2 SECTION 16127: CABLE TAGS 16127-1 THRU 16127-1 SECTION 16601: GENERAL REQUIREMENTS FOR TRACTION POWER EQUIPMENT 16601-1 THRU 16601-17 SECTION 16602: RECTIFIER TRANSFORMER 16602-1 THRU 16602-7 SECTION 16603: I500 VOLT DC SILICON RECTIFIER 16603-1 THRU 16603-9 TABLE OF CONTENTS Page 1 DISTRICT EXHIBIT 1 DRAWINGS AND TECHNICAL SPECIFICATION (Continued) DIVISION 16 – ELECTRIAL PAGES SECTION 16604: 1500 VOLT DC SWITCHGEAR 16604-1 THRU 16604-11 SECTION 16605: ANODE
    [Show full text]
  • Busway Systems
    Busway Systems Class 5600 CONTENTS Description Page Product Description . 9 Construction . 12 Application Data . 17 Layout and Measurement . 26 Installation, Special Features, and Services . 28 Electrical Data. 31 225 A–600 A Catalog Numbering System/Physical Data . 33 800 A–5000 A Catalog Numbering System/Physical Data . 42 Catalog Numbering System/Plug-In Units (“Bus Plugs”) . 59 Suggested Busway Specifications . 72 100 A Plug-In Busway. 74 100 A Plug-In Busway Suggested Specifications . 79 POWER-ZONE™ Metal-Enclosed Busway. 80 Schneider Electric Brands POWER-ZONE Metal-Enclosed Busway Suggested Specifications. 86 Busway Systems Contents PRODUCT DESCRIPTION . 9 General . 9 Sandwich Construction . 9 Totally Enclosed Housing . 9 Compact Size . 9 Finish . 9 Insulation . 9 Plating. 10 Dielectric Testing . 10 VISI-TITE® One Bolt Joint . 10 EZ JOINT PAK™ Connector Assembly . 10 Labor Savings. 10 Tie Channels. 11 Internal Smoke/Gas Barriers . 11 Short Circuit Strength . 11 Voltage Drop. 11 Outdoor Busway . 11 Universal Fittings . 11 Quality. 11 Integral Ground Bus . 11 CONSTRUCTION . 12 Plug-in Busway 225 A–600 A . 12 Plug-in Busway 800 A–5000 A . 13 Indoor Feeder Busway 800 A–5000 A . 14 Outdoor Feeder Busway 800A–5000 A . 15 APPLICATION DATA. 17 The Four Types of Busway Runs . 17 Service Entrance Run . 17 Plug-In Type Vertical Riser . 17 Plug-In Type Horizontal Run . 17 Feeder Type Tie Run. 17 Service Entrance Runs . 18 Service Heads . 18 Transformer Taps . 19 Bussed Transformer Connections. 20 Phasing . 20 Other Service Entrance Connections . 20 Plug-in Busway Horizontal Run . 22 Phasing . 22 Identification . 22 Plug-in Risers . 23 Dimensions .
    [Show full text]
  • Nureg/Cr-7175 Bnl-Nureg-98371-2012
    NUREG/CR-7175 BNL-NUREG-98371-2012 Susceptibility of Nuclear Stations to External Faults Office of Nuclear Regulatory Research AVAILABILITY OF REFERENCE MATERIALS IN NRC PUBLICATIONS NRC Reference Material Non-NRC Reference Material As of November 1999, you may electronically access Documents available from public and special technical NUREG-series publications and other NRC records at libraries include all open literature items, such as books, NRC’s Public Electronic Reading Room at journal articles, transactions, Federal Register notices, http://www.nrc.gov/reading-rm.html. Publicly released Federal and State legislation, and congressional reports. records include, to name a few, NUREG-series Such documents as theses, dissertations, foreign reports publications; Federal Register notices; applicant, and translations, and non-NRC conference proceedings licensee, and vendor documents and correspondence; may be purchased from their sponsoring organization. NRC correspondence and internal memoranda; bulletins and information notices; inspection and investigative Copies of industry codes and standards used in a reports; licensee event reports; and Commission papers substantive manner in the NRC regulatory process are and their attachments. maintained at— The NRC Technical Library NRC publications in the NUREG series, NRC Two White Flint North regulations, and Title 10, “Energy,” in the Code of 11545 Rockville Pike Federal Regulations may also be purchased from one Rockville, MD 20852–2738 of these two sources. 1. The Superintendent of Documents These standards are available in the library for reference U.S. Government Printing Office use by the public. Codes and standards are usually Mail Stop SSOP copyrighted and may be purchased from the originating Washington, DC 20402–0001 organization or, if they are American National Standards, Internet: bookstore.gpo.gov from— Telephone: 202-512-1800 American National Standards Institute nd Fax: 202-512-2250 11 West 42 Street 2.