Unilux VHP New Construction Hybrid Heat Pump
Total Page:16
File Type:pdf, Size:1020Kb
www.uniluxvhp.com General Data Model Tonne(s) CFM ESP GPM Fluid WPD UVHHP-02 0.50 250 0.10 1.88 Water 4.89 UVHHP-03 0.75 340 0.10 2.55 Water 11.35 UVHHP-04 1.00 450 0.10 3.38 Water 11.85 UVHHP-05 1.25 540 0.10 4.05 Water 14.86 UVHHP-06 1.50 650 0.10 4.88 Water 20.43 UVHHP-08 2.00 800 0.15 6.00 Water 10.80 UVHHP-10 2.50 1000 0.15 7.50 Water 14.45 UVHHP-12 3.00 1200 0.15 8.30 Water 12.73 Cooling Data Capacity Capacity WATT EER THR EWT LWT Model EAT-db EAT-wb Total Sensible UVHHP-02 80.6 66.25 6588 4991 491 13.4 8264 86 94.79 UVHHP-03 80.6 66.25 9265 6944 709 13.1 11684 86 95.16 UVHHP-04 80.6 66.25 11965 8961 905 13.2 15016 86 94.89 UVHHP-05 80.6 66.25 14824 11307 966 15.3 18119 86 94.95 UVHHP-06 80.6 66.25 19092 13866 1234 14.7 22302 86 95.13 UVHHP-08 80.6 66.25 22657 17008 1566 14.5 27998 86 95.33 UVHHP-10 80.6 66.25 27709 20914 1966 14.1 34416 86 95.18 UVHHP-12 80.6 66.25 35733 27639 2550 14.0 44434 86 96.71 Heating Data Model EAT-db EAT-wb Capacity WATT COP THA EWT LWT UVHHP-02 68 89 7158 475 4.4 5537 68.3 62.41 UVHHP-03 68 89 11908 764 5.6 9300 68.3 61.01 UVHHP-04 68 89 14435 905 4.7 11347 68.3 61.59 UVHHP-05 68 89 17375 1051 4.8 13788 68.3 61.49 UVHHP-06 68 89 21893 1407 4.6 17092 68.3 61.30 UVHHP-08 68 89 26305 1552 5.0 21011 68.3 61.30 UVHHP-10 68 89 36051 2205 4.8 28527 68.3 60.69 UVHHP-12 68 89 41131 2673 4.5 32009 68.3 60.59 Electrical Data (w/EMC) Circuit Blower FLA Model Operating Voltage Compressor RLA Compressor LRA MCA Breaker UVHHP-02 208-230/1/60 3.0 15.0 2.3 6.55 15.0 A UVHHP-03 208-230/1/60 3.70 22.0 2.3 7.43 15.0 A UVHHP-04 208-230/1/60 4.70 26.0 2.3 8.68 15.0 A UVHHP-05 208-230/1/60 5.50 26.0 2.3 9.68 15.0 A UVHHP-06 208-230/1/60 7.40 33.0 2.3 12.05 20.0 A UVHHP-08 208-230/1/60 10.90 61.6 2.8 17.73 25.0 A UVHHP-10 208-230/1/60 11.30 68.0 4.1 18.23 30.0 A UVHHP-12 208-230/1/60 15.50 83.9 4.1 25.38 35.0 A The Unilux VHP Hybrid Heat Pump combines the cooling power of a heat pump with the best heating efficiency of a fan coil for reliable, on-demand heating and cooling all year round. Residents can control all their comfort settings with our new Universe thermostat. It’s supported by our Universe app and compatible with Google Assistant and Amazon Alexa. For added comfort, we also include our advanced control board that allows for on-site plug-in diagnostics. This makes service and maintenance a breeze! Heating Cooling Heating is provided by a highly efficient hot water coil. Air flows Cooling is provided by a refrigerant compressor and DX coil. Air through the coil and is circulated through the suite by a fan. The flows through the cold coil and is distributed to the suite by a fan. hydronic coil is connected to a building-wide hot water riser and The heat pump compressor is located inside the cabinet and is boiler system. Hydronic heating is much more efficient than using a compressor and requires less electricity. It is also a much more reliable system with fewer mechanical issues. 250 CFM (0.5 Ton) 88” H x 20”W x 22”D 350 CFM (0.75 Ton) 88” H x 20”W x 22”D 450 CFM (1.0 Ton) 88” H x 20”W x 22”D 550 CFM (1.25 Ton) 88” H x 20”W x 22”D 650 CFM (1.5 Ton) 88” H x 20”W x 22”D 800 CFM (2.0 Ton) 88” H x 22”W x 22”D 1000 CFM (2.5 Ton) 88” H x 22”W x 26”D 1200 CFM (3 Ton) 88” H x 22”W x 26”D Unilux vertical stack hybrid heat pump units meet the requirements of UL 1995 / CSA22.2 #236 - Issue 2011 Standard for safety heating and cooling equipment. 1. Cabinet 20-gauge satin coat steel. Configure with front, back, left, right or top supply air openings. Cabinet is fully insulated with 1-inch fibreglass with a thermosetting resin. It is coated on the airstream side with an acrylic facing with the use of flammable adhesives. Insulation inside the unit: Flame-spread rating no more than 25; Smoke developed rating no more than 50. 2. Fan & Motor Assembly A thermally-protected, multi-speed constant volume ECM motor is resiliently mounted to a centrifugal fan which has a galvanized steel forward-curved DWDI wheel in a painted housing. 3. Refrigeration Chassis A completely removeable, floating design features an insulated compressor compartment with vibration isolation. 4. Hydronic Hot Water Coil Assembly Coils corrugated aluminum fins mechanically bonded to ½" OD Copper tube. The number of rows and circuiting are selected to suit scheduled capacities. Coils are rated for a minimum working pressure of 450 psig. 5. Stainless Steel Drain Pan The drain pan is one-piece stamped stainless steel pan designed to never leak. It’s positively sloped for drainage. The drain hose will form a running trap from the drain to condensate riser. The underside of the drain pan is insulated with ½-inch thick thermal and sound insulation. 6. Risers Supply and return risers are type ‘L’ copper and condensate risers are type ‘DWV’. All have 75 mm (3”) deep expanded ends to facilitate field installation. Supply and return risers are insulated with 1” fibreglass covered with a vapour barrier jacket, which complies with ASTM 84 for flame-spread and smoke-developed ratings. The insulation is continuous over the riser length within the height of the cabinet. 7. Universe Thermostat Digital, touchscreen thermostat is fully programmable with 4 programs per day, 3-speed fan control, temperature setting, time date and humidity level display. Wi-Fi connectivity is included for mobile and web application support and Google Assistant and Amazon Alexa connectivity. 8. Filter A 1-inch disposable filter is included with the return air grille. 9. Access Panel 20-gauge steel construction finished in a durable baked enamel powder coat. Includes a hinged door for easy filter exchange. 10. Grilles & Registers Double-deflection supply air grilles have adjustable vertical and horizontal louvers. They are constructed with light-gauge, powder-coated metal. 11. Ball Valves Shut-off ball valves with garden house thread connection. 12. Water Hoses Used to connect chassis to supply and return water connections. Isolates compressor noise from the building’s pipe system. 13. Unit Tagging Each unit is individually boxed and tagged with factory and customer-supplied information. Units can be tagged with specific room numbers, riser numbers and other unique requirements. Optional Feature: Integrated ERV with Dynamic Balancing Include an integrated energy recovery ventilator (ERV) with Unilux patented dynamic balancing in your heat pump. ERVs bring in fresh air and exhaust stale air and maximize energy savings. ERVs include anti-freeze technology and dynamic balancing to manage air pressure changes. Our state-of-the-art designs are demanded by today's best developers, engineers and owners. Contact us to learn why Unilux VHP is the preferred choice of professionals throughout North America for vertical stack hybrid heat pumps 1-7930 Huntington Rd. Woodbridge, ON L4H 4M8 www.uniluxvhp.com I 905-851-3981 I [email protected].