Viewweb/Contentfetcher?Commentpar

Total Page:16

File Type:pdf, Size:1020Kb

Viewweb/Contentfetcher?Commentpar National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Public Comment No. 97-NFPA 1700-2018 [ Global Input ] Type your content here ...Metal Roofs have change fires in structures. I belong to a small rural volunteer fire department which has on average a 7 minute in service time and longer response times. By the time of arrival fires generally have escalated and burned through a ceiling and into the attic space. On asphalt roofs the fire would burn though and self-vent. With the increased of metal roofs, what is happening is the fire cannot vent and is traveling the attic space. The metal is causing the fire and heat to impinge on roof supports long with higher heat causing a failure more rapidly. The metal roofs also hamper roof ventilation due to the ability of roof screws having an enormous holding psi. One screw can exhaust a firefighter trying to pull it loose. We have found a screw gun is much quicker. Statement of Problem and Substantiation for Public Comment Metal Roofs have change fires in structures. I belong to a small rural volunteer fire department which has on average a 7 minute in service time and longer response times. By the time of arrival fires generally have escalated and burned through a ceiling and into the attic space. On asphalt roofs the fire would burn though and self-vent. With the increased of metal roofs, what is happening is the fire cannot vent and is traveling the attic space. The metal is causing the fire and heat to impinge on roof supports long with higher heat causing a failure more rapidly. The metal roofs also hamper roof ventilation due to the ability of roof screws having an enormous holding psi. One screw can exhaust a firefighter trying to pull it loose. We have found a screw gun is much quicker. Related Item • nfpa 1700 Submitter Information Verification Submitter Full Name: Don McGuire Organization: Campbell County Rural Fire Affiliation: President of board of directors Street Address: City: State: Zip: Submittal Date: Sun Nov 11 04:46:51 EST 2018 Committee: FCO-AAA Committee Statement Committee Rejected Action: Resolution: No suggested change was submitted with the public comment. The document recognizes the inherent dangers associated with vertical ventilation by having firefighters of rooftops.The standard recommends applying water through the roof soffits and/or gable vent openings for attic fire control. 1 of 157 5/16/2019, 2:43 PM National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Public Comment No. 19-NFPA 1700-2018 [ Section No. 1.1 ] 1.1 Scope. This guide addresses structural fire-fighting strategy , tactics, and tasks as tactics as supported by science-based research. Removed "and tasks" Statement of Problem and Substantiation for Public Comment Justification: The remainder of the proposed standard does not break down into task level details. There is a strategy chapter and a tactics chapter but no chapter on tasks. There are thousands of fire ground tasks and they cannot possibly all be put into a standard. Related Item • PI? Submitter Information Verification Submitter Full Name: Eric Maurouard Organization: Olean Fire Street Address: City: State: Zip: Submittal Date: Thu Sep 20 08:09:57 EDT 2018 Committee: FCO-AAA Committee Statement Committee Action: Accepted Resolution: SR-11-NFPA 1700-2019 Statement: Proposed guideline does not break down into task level details. 2 of 157 5/16/2019, 2:43 PM National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Public Comment No. 20-NFPA 1700-2018 [ Sections 1.2, 1.3 ] Sections 1.2, 1.3 1.2 Purpose. The purpose of this document is to provide guidance for the development of policies, procedures, and guidelines including strategies, tactics, and tasks for structural firefighting supported by science-based research. Removed "and tasks" for same reason as section 1. 1. 1. 3 Application. The intent of this guide is to provide guidance on the application of science-based fire dynamics research supporting fire-fighting practices recognizing that life safety of the public and the first responder is the highest incident priority, followed by incident stabilization and property conervation . Statement of Problem and Substantiation for Public Comment 1.2 - Justification is the same as 1.1. 1.3 - Justification: You currently do not mention the 3 incident priorities until section 10.4.2. In my opinion, they should be mentioned earlier in the document. On a side note: I suggest a title revision to the standard. (There is no place to edit the actual title so I'm doing it here) Section 1.3 reads "The intent of this guide is to provide guidance on the application of science-based fire dynamics research supporting fire-fighting practices..." The title NFPA 1700 should be changed to specifically reflect this. Currently the title is "NFPA 1700: The Guide to Structural Firefighting", but this standard only focuses on "water and air" based on fire dynamic research. It is in fact, in its current capacity, not a complete guide to structural firefighting. A true guide to structural firefighting would cover everything from water supply, search, command and ICS, controlling utilities, laddering the building, RIT, forcible entry, etc... If you only intend to discuss fire dynamic research as it can be applied to fire attack, then you should name the standard accordingly. Related Item • PI Submitter Information Verification Submitter Full Name: Eric Maurouard Organization: Olean Fire Street Address: City: State: Zip: Submittal Date: Thu Sep 20 08:23:25 EDT 2018 Committee: FCO-AAA Committee Statement Committee Action: Rejected but see related SR Resolution: SR-12-NFPA 1700-2019 Statement: Task level elements are not addressed in the guideline. 3 of 157 5/16/2019, 2:43 PM National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Public Comment No. 21-NFPA 1700-2018 [ Section No. 3.3.34 ] 3.3.34 * Decontamination. The process of removing contaminants such as soot, particulate, and fireground chemicals to clean fireground tools and equipment and prevent the spread of contamination to other persons or equipment. 3.3.34.1 Dry Decontamination. Utilizing forced airflow or brushing off of personnel, PPE, apparatus, tools, and equipment to reduce contaminants. 3.3.34.2 Gross Decontamination. The initial phase of the decontamination process during which the amount of surface contaminant is significantly reduced by removing bulk contaminants and substances from the surface of the equipment or tools using some form of brushing, wetting agent, and/or detergents. 3.3.34.3 Wet Decontamination. Utilizing water or a water and soap solution to reduce contaminants on personnel, PPE, apparatus, tools, and equipment. Statement of Problem and Substantiation for Public Comment Decontamination should be its own standard. Remove decontamination from the definitions and Chapter 11 in its entirety. Related Item • PI Submitter Information Verification Submitter Full Name: Eric Maurouard Organization: Olean Fire Street Address: City: State: Zip: Submittal Date: Thu Sep 20 08:57:14 EDT 2018 Committee: FCO-AAA Committee Statement Committee Action: Rejected Resolution: Definitions are required to support concepts in Chapter 11. 4 of 157 5/16/2019, 2:43 PM National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Public Comment No. 22-NFPA 1700-2018 [ Section No. 3.3.35 ] 3.3.35 Defensive Strategy. The plan for the actions or movements of the arriving fire of fire department units to protect exposures and control the contain the main body of fire with the intent to not enter the fire building. the already-affected areas. Statement of Problem and Substantiation for Public Comment Remove "the arriving" Justification: Strategy is not solely an initial plan for "arriving units". Strategy can change late in the incident after all units have arrived. Saying strategy is for arriving units is just confusing. Remove "control"; replace with "contain" Justification: In a defensive strategy we often allow the fire to burn uncontrolled so long as it is contained to the area that is already burning. Contain is just a better word to use here. If you don't like "contain" my second preference would be "confine" which is what is used in RECEO-VS. Remove "with the intent to not enter the fire building" Defensive strategies are not limited to exterior operations. You can implement a defensive strategy to protect interior exposures. Tactics such as shelter in place or trench cuts (with hose lines on the top floor under the trench cuts) are interior defensive tactics to fulfill a defensive strategy. Add "contain the main body of fire to the already affected areas" This is the true essence of what a defensive strategy is. We are writing off buildings or portions of the building that we cannot save and focusing our efforts to protect interior or exterior exposures. Related Public Comments for This Document Related Comment Relationship Public Comment No. 25-NFPA 1700-2018 [Section No. 3.3.146] Related Item • PI Submitter Information Verification Submitter Full Name: Eric Maurouard Organization: Olean Fire Street Address: City: State: Zip: Submittal Date: Thu Sep 20 09:02:44 EDT 2018 Committee: FCO-AAA Committee Statement Committee Accepted Action: Resolution: SR-19-NFPA 1700-2019 5 of 157 5/16/2019, 2:43 PM National Fire Protection Association Report https://submittals.nfpa.org/TerraViewWeb/ContentFetcher?commentPar... Statement: The TC removed "the arriving," whereas strategy is not solely an initial plan for "arriving units". Strategy can change late in the incident after all units have arrived. Saying strategy is for arriving units is just confusing. In addition "control" is replaced with "contain", and "with the intent to not enter the fire building" is removed.
Recommended publications
  • Fire Service Features of Buildings and Fire Protection Systems
    Fire Service Features of Buildings and Fire Protection Systems OSHA 3256-09R 2015 Occupational Safety and Health Act of 1970 “To assure safe and healthful working conditions for working men and women; by authorizing enforcement of the standards developed under the Act; by assisting and encouraging the States in their efforts to assure safe and healthful working conditions; by providing for research, information, education, and training in the field of occupational safety and health.” This publication provides a general overview of a particular standards- related topic. This publication does not alter or determine compliance responsibilities which are set forth in OSHA standards and the Occupational Safety and Health Act. Moreover, because interpretations and enforcement policy may change over time, for additional guidance on OSHA compliance requirements the reader should consult current administrative interpretations and decisions by the Occupational Safety and Health Review Commission and the courts. Material contained in this publication is in the public domain and may be reproduced, fully or partially, without permission. Source credit is requested but not required. This information will be made available to sensory-impaired individuals upon request. Voice phone: (202) 693-1999; teletypewriter (TTY) number: 1-877-889-5627. This guidance document is not a standard or regulation, and it creates no new legal obligations. It contains recommendations as well as descriptions of mandatory safety and health standards. The recommendations are advisory in nature, informational in content, and are intended to assist employers in providing a safe and healthful workplace. The Occupational Safety and Health Act requires employers to comply with safety and health standards and regulations promulgated by OSHA or by a state with an OSHA-approved state plan.
    [Show full text]
  • Lofer Fire and Flash Fire Update 09-08-20
    UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF INDIAN AFFAIRS Fort Apache Agency P.O. Box 560 Whiteriver, Arizona 85941 Bureau of Indian Affairs, Wildland Fire Management News Release Phone line: (928)421-4984 Email: [email protected] Lofer Fire and Flash Fire Update for September 08, 2020 Lofer Fire Summary Location: 15 miles east of Whiteriver Containment: 50% Fire Cause: Lightning Fuel Type: Timber, brush, litter Fire Size: 1,256 acres Resources: 133 incident personnel Lofer Fire: Yesterday afternoon, crews carried out firing operations along the K.L. Ridge which allowed firefighters to strengthen containment lines and promote a low intensity backing fire down Big Bonito Creek. Firefighters have begun to restore areas disturbed by containment and suppression efforts. This is being done to limit erosion along fire lines as well as to enhance the aesthetics of the landscape. Today, crews will be assessing if there is an additional need for firing operations while other resources will continue with suppression repair efforts. There will be a local type 3 organization transitioning tomorrow evening for the Lofer and Flash Fires. As containment continues to increase and fire activity decreases, the updates for the fire will only be posted to the BIA Forestry & Wildland Fire Management – Fort Apache Agency if there are any significant changes. Flash Fire: The Flash Fire is 51 acres in size and approximately 90 percent contained. Values and Objectives: Safety of incident responders and the public remains the number one priority. Incident personnel will continue to protect traditional gathering sites, recreation areas, the Mount Baldy Wilderness, commercial timberlands and watersheds, and continue to protect riparian areas to the Apache trout.
    [Show full text]
  • Fireboats and Search and Rescue Boats with a Small Firegigting
    The United States has a long history of fire departments using surplus property from other government agencies , re purposing property within departments, and sometimes other agencies reusing obsolete fire apparatus. Fireboats and Search and Rescue Boats have been converted from military and other government agencies surplus since the end of World War I. It is unlikely there will be any future conversions of large high gallon per minute capacity, 5,000 gpm or more, fireboats from surplus craft . It is possible that some of the tractor tugs built for the U.S. Navy with substantial fire fighting features and capability included could be made available through the Federal Government surplus property transfer programs in a few decades. Large fireboats have since the 1970s been built using features from tugboats, but have many special design features to deal with hazardous materials etc. Search and Rescue and small fireboats of no more the 2,000 or so gallons per minute are still sometimes converted from surplus craft obtained from other government agencies. In 1921, the Baltimore City Fire Department received, by loan from the U.S. Navy, the 110 foot long anti-submarine warfare vessel SC 428 . Ship was built between 1917-and 1919 . Boat was loaned for the purpose of conversion into a fireboat. The ship, renamed Cascade in 1949, served the fire department until 1960. The city received titled to the ship in 1949 through legislation passed by the House and Senate and signed by President Truman. The U.S. Army built several 98 foot tugboat type workboats ,in the early 20th century, to assist with maintaining coastal defense minefields.
    [Show full text]
  • Session 611 Fire Behavior Ppt Instructor Notes
    The Connecticut Fire Academy Unit 6.1 Recruit Firefighter Program Chapter 6 Presentation Instructor Notes Fire Behavior Slide 1 Recruit Firefighter Connecticut Fire Academy – Recruit Program 1 Slide 2 © Darin Echelberger/ShutterStock, Inc. CHAPTER 6 Fire Behavior Connecticut Fire Academy – Recruit Program Slide 3 Some have said that fires in modern furnished Fires Are Not Unpredictable! homes are unpredictable • A thorough knowledge of fire behavior will help you predict fireground events Nothing is unpredictable, firefighters just need to know what clues to look for Connecticut Fire Academy – Recruit Program Slide 4 Connecticut Fire Academy Recruit Program CHEMISTRY OF COMBUSTION Connecticut Fire Academy – Recruit Program 1 of 26 Revision: 011414 The Connecticut Fire Academy Unit 6.1 Recruit Firefighter Program Chapter 6 Presentation Instructor Notes Fire Behavior Slide 5 A basic understanding of how fire burns will give a Chemistry firefighter the ability to choose the best means of • Understanding the • Fire behavior is one of chemistry of fire will the largest extinguishment make you more considerations when effective choosing tactics Fire behavior and building construction are the basis for all of our actions on the fire ground Connecticut Fire Academy – Recruit Program Slide 6 What is Fire? • A rapid chemical reaction that produces heat and light Connecticut Fire Academy – Recruit Program Slide 7 Types of Reactions Exothermic Endothermic • Gives off heat • Absorbs heat Connecticut Fire Academy – Recruit Program Slide 8 Non-flaming
    [Show full text]
  • Colorado Fire Commission Recommendation 20-01
    COLORADO FIRE COMMISSION RECOMMENDATION 20-01 Implement the Colorado Coordinated Regional Mutual Aid System (CCRMAS) Statutory Duties: Per 24-33.5-1233(4)(b)(VI) The Commission will strengthen regional and statewide coordination of mutual aid resources and initial attack capabilities for fires and other hazards. Assumptions: 1. Rapidly expanding incidents can overwhelm the resources of the local fire department and surrounding agencies. 2. Local mutual aid plans exist but there is limited coordination across regions to activate additional resources quickly during rapidly expanding incidents. 3. Decreasing activation time can help minimize the impacts of an incident. 4. During the initial stages of an incident, dispatch centers, and local first responders will be focused on their primary response duties and unable to assist with coordinating rapid mutual aid mobilization. Emergency managers and emergency operations centers will be in the process of being stood up in support of extended response should it become necessary and in preparation for consequence management of subsequent impacts of the emergency response. 5. The statewide coordinated regional mutual aid system covers the time between the start of an incident and when adequate resources arrive for prolonged response through interagency systems and/or local and state Emergency Operations Centers. 6. The goal is to develop a unified approach to mobilizing fire and EMS resources, eliminate redundancy, and eliminate duplicate orders with the end goal of integration into the state response system. 7. A statewide coordinated regional mutual aid system, with dedicated resources for implementation, will help with the coordination and movement of mutual aid resources without impacting local dispatch centers which are busy managing 911 calls and resource response.
    [Show full text]
  • Two Fire Fighters Die and Three Fire Fighters Injured in a Fire Apparatus Crash—West Virginia
    2018 08 August 23, 2019 Two Fire Fighters Die and Three Fire Fighters Injured in a Fire Apparatus Crash—West Virginia Executive Summary On March 24, 2018, a pumper, Rescue 111 from county Fire Station 11 crashed while enroute to a report of an accident with injuries on an interstate. A 46-year-old assistant chief and a 40-year-old lieutenant died when the pumper struck a rock outcrop that paralleled the roadway. The 46-year-old fire chief (the fire apparatus operator), a 59-year-old fire fighter and a 17-year old junior fire fighter were injured. Fire Station 11 was dispatched by the county 9-1-1 center (Metro911) at 1733 hours for an accident with injuries on an interstate. At approximately 1741 hours, Metro911 received notification of a fire truck rollover. At 1742 hours, this information was updated that “a fire truck had crashed into a rock wall.” County Medic 147, who was responding behind Rescue 111arrived on scene at 1743. Another pumper, Engine 113, from Fire Station 11 was responding and arrived on scene at approximately 1744 hours. The fire apparatus operator of Engine 113 and the county medics immediately started to assess the patients of Rescue 111. One fire fighter (lieutenant) was found deceased on the ground at the tailboard of Rescue 111 The fire department pumper after the rescue of near the shoulder of the roadway. County the three injured fire fighters. The damage to Medic 147 advised the county dispatcher at the pumper was done by the rock outcrop. 1747 hours there was one fire fighter (Photo courtesy of the West Virginia State Police.) fatality and two fire fighter injuries.
    [Show full text]
  • 2020 Madera-Mariposa-Merced Unit Fire Plan
    Madera-Mariposa-Merced Unit Fire Plan 2020 MMU Strategic Fire Plan Madera-Mariposa-Merced Unit Madera-Mariposa-Merced Unit Fire Plan 2020 UNIT STRATEGIC FIRE PLAN AMENDMENTS Page Section Date Numbers Description of Update Updated By Updated Updated 4/2020 Contents Page i-ii 2020 Update P4224 4/2020 Signature Page 1 Annual Update P4224 4/2020 Executive 2 Update C4200 Summary 4/2020 I Update P4224 4/2020 II None P4224 4/2020 III Update P4224 4/2020 IV Update B4220 4/2020 IV (B) Update F4208 3/2020 V Update All Battalions 4/2020 Appendix A Update P4224 4/2020 Appendix B None P4224 4/2020 Appendix C None P4224 4/2020 Appendix C-1 None P4224 4/2020 Appendix C-2 None P4224 4/2020 Appendix D None B4220 4/2020 Appendix E Update B4220 3/2020 Appendix F New P4224 4/2020 Appendix G Update B4211 3/2020 Appendix H None B4212 3/2020 Appendix I Update B4214 4/2020 Appendix J None B4215 4/2020 Appendix K None B16 4/2020 Appendix L None B17 3/2020 Appendix M Update B18 4/2020 Appendix N Update D4206 4/2020 Exhibits: Maps None GIS 4/2020 Accomplishments Update Various i Madera-Mariposa-Merced Unit Fire Plan 2020 Table of Contents UNIT STRATEGIC FIRE PLAN AMENDMENTS ............................................................. i Table of Contents .............................................................................................................ii SIGNATURE PAGE ........................................................................................................ 1 EXECUTIVE SUMMARY ................................................................................................
    [Show full text]
  • Flashover, Backdraught and Fire Gas Ignitions
    This document was archived on 30 March 2020 Fire and Rescue Service Operational Guidance Archived GRA 5.8 flashover, backdraught and fire gas ignitions 6013 GRA TPAGES V1_1.indd 3 3/8/09 09:11:21 This document was archived on 30 March 2020 Operational procedures as per FRS policy Operational procedures and supervision in identification of indicators and Training methods of ventilation accepted to the current PPE manufactured standard as per FRS policy Operational procedures and supervision in identification of indicators and Training methods of attack accepted to the current PPE manufactured standard Generic Risk Assessment 5.8 Persons at risk Measures Control Wholetime Day crewed Retained Volunteers Other emergency service personnel Public Wholetime Day crewed Retained Volunteers Other emergency service personnel Public Flashover, backdraught and fire gas ignitions Risk Fire and explosion Fire Blast injury Fire and explosion Fire Blast injury August 2009 Archived Hazard Rapid fire spread/backdraughtRapid fire Burns and scalds Rapid fire spread/flashoverRapid fire Burns and scalds Task tactical ventilation compartment the where thermal radiation generated by is high, the fire causing the room contents to give flammable off gases. Ref. No Description 4 Carrying out Reference number for the risk Reference – the specific activity being carried out Task giving rise to the risk present – Hazard Hazard together with an indication of how serious that somebody could be harmed by these and other hazards, Risk – the chance, high or low, Persons
    [Show full text]
  • Prescribed Burn Equipment
    Oklahoma Cooperative Extension Service NREM-2899 Prescribed Burn Equipment November 2016 John R. Weir Oklahoma Cooperative Extension Fact Sheets Research Associate, Natural Resource Ecology and Management, are also available on our website at: Oklahoma State University http://osufacts.okstate.edu R. Seth Coffey Graduate Research Assistant, Natural Resource Ecology and Man- agement, Oklahoma State University Carol E. Blocksome Research Assistant Professor, Horticulture and Natural Resources, Kansas State University Morgan L. Russell Extension Range Specialist, Ecosystem Science and Manage- ment, Texas A&M Agrilife Extension Service Dirac Twidwell Assistant Professor, Department of Agromony and Horticulture, University of Nebraska-Lincoln Introduction Having proper or adequate equipment on a prescribed fire is just as important as writing burn plans, firebreak prepa- rations or having the correct weather conditions. Oftentimes, burn managers will make equipment checklists prior to the burn; ensuring all needs have been met. Equipment may range from what the crew should wear to the type of pumper unit one might have on a fire. In planning a prescribed burn, one of the most important steps is considering what equipment is needed to properly protect the burn crew and contain the fire. There is no standard equipment list for conducting a burn. However, it is important to consider all equipment that could be used to make the prescribed burn safer and easier. When determining what equipment is needed it is best to go by the adage of “better to have it and not need it, than need it and not have it.” Always remember no two burns are the same and each burn can require different pieces of equipment.
    [Show full text]
  • Living on the Wildside
    JOURNAL nfpaTHE SOURCE FOR FIRE, ELECTRICAL, BUILDING, & LIFE SAFETY INFORMATION LIVING ON THE WILD SIDE The worst U.S. wildfire season in years forces thousands of people to evacuate communities bordering wildlands MARCH/APRIL 2003 WWW.NFPAJOURNAL.ORG FIRSTWORD ANYONE WHO ENJOYS visiting the wildlands Firewise Communities/USA Program, NFPA of the United States can probably tell at least one and its partners educate Americans about wild- tale about a benign hike in the woods that sud- fires and help communities develop programs denly brought them back in touch with the tailored to their needs. realities of nature. On more than one occasion, I The Firewise Communities/USA Program pro- have begun a hike in the White Mountains of jects vary from community to community. In New Hampshire on a warm spring day, only to Briargate, Florida, for example, the program was find myself fighting through a snowstorm an used to develop strategies that will help the com- hour or two later. munity avoid a repeat of problems faced when Many of the thousands of Americans who wildfires hit the area in 1998. A million-gallon choose to live in areas abutting our nation’s (3,785,344-liter) water tank is now available for wildlands have also learned that, along with the fighting fires, dirt from excavated lakes was used Making wildfire prevention a life safety priority beautiful views and to establish firebreaks, and pine forests have been peaceful surround- thinned. At River Bluff Ranch, near Spokane, ings, comes the threat Washington, roads have been improved, utilities of wildfire engulfing are now underground, and covenants require their communities.
    [Show full text]
  • Fire Fighter Course Outline
    San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833 Fire FighterTechnology Course Outline Classroom CC 1 Introduction to ROP 5.0 0 • ROP Philosophy and operation • Enrollment forms • Emergency cards • Class rules and regulations • Program expectations and competencies 2 Fire Service Organization and Safety 24.0 0 • Fire Department functions and resources • Management systems and fire service ranks and positions • Safety and fitness • Sexual harassment and cultural diversity • General safety for all emergency situations • Personnel accountability • Firefighter injuries and fatalities 3 Fire Behavior and Extinguishment Theory 11.0 0 • Types of heat transfer and measurement • Sources of heat energy • Terms related to combustion • Combustion process, products of combustion, and combustion gasses • Phases of fire • Characteristics of pyrolysis, rollover, flashover, and backdraft • Characteristics of fire extinguishing agents and water as they relate to firefighting 4 Building Construction 10.5 0 • Introduction to building construction • Building components • Fire resistive rating for walls and buildings • Roof construction • Indications of potential building collapse 5 Firefighter Personal Protective Equipment and SCBA’s 7.5 4.0 • Personal protective equipment for the fire service • Reasons why PPE can fail • How to don PPE • Conditions requiring respiratory protection 2/11/2014 1 San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833 • Types
    [Show full text]
  • Fire Gas Ignition
    Fire Gas Ignition In the Belgian fire service the phenomena of flashover and backdraft are pretty well known. The fourth article of this series elaborated on the subject of backdraft. The sixth article covered flashover. The existence of a third family of fire phenomena is less known however. This family is called Fire Gas Ignitions (FGI). FGI is a term to describe all the events that don’t really fit the definition of flashover, nor that of backdraft. The most common occurrences of FGI are discussed below. 1 Flashfire During a fire, a lot of smoke gas is being produced. This smoke is hot and it’s mobile. It will spread through openings and cracks. Possibly smoke will amass in a space somewhere near the fire. The example that obviously comes to mind is that of a false ceiling. It’s also possible that the smoke gas exits the room through cracks at the door and enters the neighboring compartment where it will form a layer up against the ceiling. It may even happen that smoke amasses in a built in closet or a false wall. Houses made up of a wooden frame often have shafts built into the structure. After entering these shafts, the smoke will spread out into the building. This will cause flammable smoke gas to appear in places where it is least expected. When sufficient smoke gas has been added into a room, a mixture of gas and air will be formed that’s inside flammability limits (see Fig. 1.1). At that point, two sides of the fire triangle are present.
    [Show full text]