Infrared Imaging Bolometers

Total Page:16

File Type:pdf, Size:1020Kb

Infrared Imaging Bolometers — 29 — Infrared imaging bolometers Harry A. C. EatonI Abstract Infrared imaging bolometers have found great utility in space imaging appli- cations. Bolometers measure incident energy by observing a temperature change caused when a material absorbs photons. Because there is great flexibility in choos- ing the absorbing material characteristics, bolometers can readily be designed to have narrow or broad-band characteristics over a wide range of wavelengths. Ima- ging bolometers are simply formed from arrays of individual bolometers in the focal plane of a telescope. Uncooled bolometers with high pixel counts are applied for studying the Sun and planets, while imaging bolometers cooled to very low tem- peratures but having only a few pixels have been designed for deep-space imaging applications, typically in the very-long wavelength to sub-millimetre region. Ultra- low temperature imaging bolometers have achieved detectivities better than the best photo-current detectors in the far-infrared region. Introduction Bolometers are capable of detecting radiant energy over a very broad spec- tral range but have found their greatest utility in the infrared range. Most recent developments of imaging bolometers have focused on the long-wave IR (LWIR) ñ range from 8 ñm to 13 m because the atmosphere is fairly transparent in this range, which also encompasses the peak emission from warm objects on Earth. While these developments are driven by commercial and military market interest the resulting technologies are quite usefully adapted to space applications. Many commercial imaging bolometers that are designed for the LWIR can be adapted ñ ñ ñ for use in short-wave (SWIR, 1 ñmto 3 m) and midwave (MWIR, 3 mto 8 m) ranges. With somewhat greater difficulty they can be adapted for far infrared or very broad-band applications as well (Foukal and Libonate 2001). For faint or cold astronomical targets, cryogenically cooled very long-wave IR (VLWIR) and sub- millimetre bolometer arrays have been developed, and these have recently been adapted for use in space. IJohns Hopkins University Applied Physics Laboratory, Laurel MD, USA 477 478 29. Infrared imaging bolometers History In the 1980s the Defense Advanced Research Project Agency (DARPA) funded researchers at Honeywell International and Texas Instruments to develop small un- cooled infrared imagers using micro-bolometer arrays. The results of this research were declassified in 1992 and have led to an explosive growth in both research on bolometer-based imagers as well as commercially available bolometer focal-plane arrays (FPA). The first uncooled micro-bolometer FPA was flown in space in 1997 (Spinhirne et al 2000). Since that time there have been many space missions incor- porating micro-bolometer FPAs, most of which have been for Earth and planetary observations. The first cryogenically cooled IR bolometer array to fly in space was the FIRP instrument on board the Japanese IRTS satellite flown in 1995 (Hirao et al 1996). Since then major advancements in low-temperature bolometers have resulted in detectivities surpassing those of photon-detector technologies. Bolometer fundamentals In its simplest form, a bolometer consists of an energy-absorbing material con- nected to a thermometer with a weak thermal connection to a constant-temperature heat sink. Incident radiant energy heats the absorber, raising its temperature, which is measured by the thermometer. A wide range of materials can be used as the energy absorber, allowing bolometer designers significant freedom to con- trol the operating spectral range, including broad and narrow tuning ranges in wavelength, λ. Figure 29.1 shows the schematic structure of a bolometer element. The absorber/thermometer’s heat capacity is Cp while Gc represents the equiva- lent thermal conductance from the element to the heat sink including (linearized approximations of) any radiative and convective components. Solving the heat- balance equation (ignoring any self-heating of the thermometer) gives the rise in the detector element temperature ε(λ)P (λ) ∆T = dλ , (29.1) 2 2 2 Z Gc + ω Cp q where ε is the emissivity of the absorber, P is the power incident on the absorber element, and ω is the frequency of the incident power envelope. Since low Gc im- proves the bolometer performance, steps are taken to minimize it including using low-emissivity materials on the detector back side (facing the heat sink), evacuated packages and long, thin support and connecting elements with low thermal con- 7 ductivity. Values for Gc of 10 W/K are typical for micro-bolometer arrays. The speed of response of a bolometer is governed by the bolometer time constant Cp τb = , (29.2) Gc and is much slower than most photon detectors. For micro-machined structures found in typical bolometer FPAs, the heat capacity is low enough for response times of the order of a few milliseconds. 479 Figure 29.1: A schematic representation of a bolometer element. Incident energy from above heats the absorber element. The maximum bolometer detectivity is limited by random fluctuations in the radiant power exchange between the detector and scene and is given by (Rogalski 2002) ε D∗ = , (29.3) b 8 k σ (T 5 + T 5) r B d s where kB is Boltzmann’s constant, σ is the Stefan-Boltzmann constant, Td is the detector temperature, and Ts is the scene temperature. This formula provides an upper bound for bolometer detectivity. In practice additional noise sources in the thermometer and phonon noise of the detector element reduce the detectivity. As can be seen from Equation 29.3, it is desirable that the detector be colder than the scene temperature, but there are diminishing returns for additional cooling. In practice this means that observations of warm targets such as the Sun, Earth and planets can easily be accomplished with detectors near room temperature, but astrophysical observations must been done with detectors cooled to a few kelvins or less. Uncooled bolometer arrays The primary figure of merit for uncooled FPA performance is the noise equiva- lent temperature difference (NETD, ∆TNE). NETD is the temperature difference across a black-body source that produces a signal difference equal to the rms de- tector noise. It is given by: 4 F 2 B ∆T = , (29.4) NE π ∗ ∂R A D ∂T r where F is the ratio of the focal length of the optics to its aperture diameter, ∂R ∂T is the derivative of the black-body radiance with respect to temperature at the wavelength of operation, D∗ is the actual pixel detectivity, B is the noise bandwidth 480 29. Infrared imaging bolometers of the measurement, and A is the area of the detector pixel. NETD is dependent on integration time (frame rate) because the detector noise is a function of the measurement bandwidth. The area dependence of the NETD makes the filling factor of the array an important parameter to optimize. NETDs as low as 23 mK ñ have been reported for micro-bolometer arrays having 50 ñm 50 m pixel size with F/1 optics operating at room temperature at 60 frames per× second (Howard 2000). For cryogenically cooled detectors the NETD is not reported because the temperature derivative of radiance is very small at cold temperatures. Thermometers Various technologies are available to measure the temperature rise of the de- tector element. These include temperature-dependent resistance (thermistors), py- roelectric and ferroelectric effects, thermopiles, and mechanical cantilevers. Each technique has various advantages and disadvantages, especially for FPAs. Tempe- rature-dependent resistive sensors are dominant in the market at present and have the advantages of monolithic array fabrication (with resulting low cost) and very good detectivity; drawbacks include complex element trimming circuitry and high 1/f noise. Pyroelectric and ferroelectric detectors sense changes in temperature and therefore require a chopper to modulate the signal, but are not affected by 1/f noise and are minimally affected by static offset variations across the array. Pyroelectric materials also require hybrid assembly techniques that raise the Gc and Cp values, but they do have the advantage that the hybrid structure can be coated with materials that are also not amenable to monolithic processing such as gold-black. Thermopiles (Kanno et al 1994) allow high linearity and negligible 1/f noise, but suffer from low signal levels with resulting poor detectivities and NEDT. Mechanical cantilever sensors operate at DC and theoretically have better noise performance (Datskos et al 2004), but require bulky and complex readout systems. Temperature-dependent resistance sensors (thermistors) Vanadium oxide (VOx) is the dominant temperature-sensitive resistance mate- rial used for uncooled monolithic IR FPAs, although many FPAs use amorphous silicon. A very large amount of research and technology development has gone into perfecting monolithic FPAs based on these technologies. Much of the improvements have focused on improving spatial NETD problems through on-array correction techniques. The growing trend towards higher pixel counts has resulted in smaller pixel sizes, yet reductions in circuit noise have kept pace to maintain similar NETD (Murphy 2002). Resistance-type micro-bolometer FPAs have been used in several Earth-observation and planetary space missions (Murphy et al 2000; Corlay and Arnolfo 2001; Lancaster et al 2003; Pope et al 2006). Pyroelectric sensors Among the uncooled IR FPAs the pyroelectric FPAs gained favour rapidly. This was primarily due to the superior uniformity and resulting good image qua- lity. Another advantage to such capacitive temperature sensors is that there is no 481 self-heating of the temperature sensing element. The main drawback to the techno- logy is the hybrid fabrication technique required to integrate the sensor into the electronic readout, even though this was actually an advantage for an application to solar astronomy because it allowed a relatively simple means to coat the detector with a thin film of gold-black to establish a broad, flat spectral response.
Recommended publications
  • Monolayer Graphene Bolometer As a Sensitive Far-IR Detector Boris S
    Monolayer graphene bolometer as a sensitive far-IR detector Boris S. Karasik*a, Christopher B. McKitterickb, Daniel E. Proberb aJet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA USA 91109; bDepts. of Phys. and Appl. Phys., Yale University, 15 Prospect St., BCT 417, New Haven, CT USA 06520 ABSTRACT In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few µm2 of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature ~ 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity. The analysis shows that the readout contribution can be reduced to that of the bolometer phonon noise if the detector device is operated at 0.05 K and the JNT signal is read at about 10 GHz where the Johnson noise emitted in equilibrium is substantially reduced. Beside the high sensitivity (NEP < 10-20 W/Hz1/2), this bolometer does not have any hard saturation limit and thus can be used for far-IR sky imaging with arbitrary contrast.
    [Show full text]
  • Pixel-Wise Motion Deblurring of Thermal Videos
    Pixel-Wise Motion Deblurring of Thermal Videos Manikandasriram S.R.1, Zixu Zhang1, Ram Vasudevan2, and Matthew Johnson-Roberson3 Robotics Institute1, Mechanical Engineering2, Naval Architecture and Marine Engineering3 University of Michigan, Ann Arbor, Michigan, USA 48109. fsrmani, zixu, ramv, [email protected] https://fcav.engin.umich.edu/papers/pixelwise-deblurring Abstract—Uncooled microbolometers can enable robots to see in the absence of visible illumination by imaging the “heat” radiated from the scene. Despite this ability to see in the dark, these sensors suffer from significant motion blur. This has limited their application on robotic systems. As described in this paper, this motion blur arises due to the thermal inertia of each pixel. This has meant that traditional motion deblurring techniques, which rely on identifying an appropriate spatial blur kernel to perform spatial deconvolution, are unable to reliably perform motion deblurring on thermal camera images. To address this problem, this paper formulates reversing the effect of thermal inertia at a single pixel as a Least Absolute Shrinkage and Selection Operator (LASSO) problem which we can solve rapidly using a quadratic programming solver. By leveraging sparsity and a high frame rate, this pixel-wise LASSO formulation is able to recover motion deblurred frames of thermal videos without using any spatial information. To compare its quality against state-of- Fig. 1: An illustration of the proposed motion deblurring algorithm for the-art visible camera based deblurring methods, this paper eval- microbolometers. The top image shows a visible image captured at 30fps with uated the performance of a family of pre-trained object detectors auto exposure.
    [Show full text]
  • Infrared Imaging Video Bolometer with a Double Layer Absorbing Foil
    Plasma and Fusion Research: Regular Articles Volume 2, S1052 (2007) Infrared Imaging Video Bolometer with a Double Layer Absorbing Foil Igor V. MIROSHNIKOV, Artem Y. KOSTRYUKOV and Byron J. PETERSON1) St. Petersburg State Technical University, 29 Politechnicheskaya Str., St. Petersburg, 195251, Russia. 1)National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, 509-5292, Japan (Received 30 November 2006 / Accepted 11 August 2007) The object of the present paper is an infrared video bolometer with a bolometer foil consisting of two layers: the first layer is constructed of radiation absorbing blocks and the second layer is a thermal isolating base. The absorbing blocks made of a material with a high photon attenuation coefficient (gold) were spatially separated from each other while the base should be made of a material having high tensile strength and low thermal con- ductance (stainless steel). Such a foil has been manufactured in St. Petersburg and calibratedinNIFSusinga vacuum test chamber and a laser beam as an incident power source. A finite element method (FEM) code was applied to simulate the thermal response of the foil. Simulation results are in good agreement with the experi- mental calibration data. The temperature response of the double layer foil is a factor of two higher than that of a single foil IR video bolometer using the same absorber material and thickness. c 2007 The Japan Society of Plasma Science and Nuclear Fusion Research Keywords: plasma bolometry, infrared imaging bolometer, double layer foil, finite element method simulation DOI: 10.1585/pfr.2.S1052 1. Introduction 2. Double Layer Foil Design and Man- The idea of infrared imaging bolometry is to absorb ufacturing the incident plasma radiation in an ultra thin (1 µm-2.5 µm) The idea of DLF design is shown in Fig.
    [Show full text]
  • Designing of Sensing Element for Bolometer Working at Room Temperature
    IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-ISSN: 2278-2834,p- ISSN: 2278-8735. PP 47-52 www.iosrjournals.org Designing of Sensing Element for Bolometer Working at Room Temperature 1 2 Debalina Panda , Subrat Kumar Pradhan 1 M.Tech Scholar, Dept. of ECE, Centurion University of Technology &Management, Odisha, INDIA 3 Asst. Professor, Dept. of ECE, Centurion University of Technology &Management, Odisha, INDIA Abstract: Bolometer is a highly sensitive thermal detector used for detection of heat or electromagnetic radiation. It has vast applications extending their range to the field of military, medical, astronomy, particle physics and in day-to-day use thus devising it as a significant part of our society. The basic operation principle is that it measures the incident radiation power through absorption resulting a specific change in a measurable quantity. This present work aims at designing of a MEMS based bolometer analysing the variation of thermal conductivity in response to the temperature by using COMSOL Multiphysics®. Here the temperature change occurs due to the incident infrared radiation. The proposed bolometer design is efficient of operating at elevated temperatures (>273 K) and thus can be implemented in a Wheatstone bridge to make it a modifiable detector for better sensitivity. I. Introduction Bolometer is light, rugged, reliable and low cost resistive thermal detectors generally used for low temperature operation. These are radiation power detectors constructed from a material having very small thermal capacity and large thermal coefficient so that the absorbed incident radiation produces a large change in resistance. It consists of an absorptive element connected to a thermal reservoir (or heat sink) and a thermopile attached to it for measurement of temperature as shown in Fig.1.
    [Show full text]
  • Development of Cryogenic Bolometer for Neutrinoless Double Beta Decay in 124Sn
    Development of Cryogenic Bolometer for Neutrinoless Double Beta Decay in 124Sn By Vivek Singh PHYS01200804030 Bhabha Atomic Research Centre, Mumbai – 400 085 A thesis submitted to the Board of Studies in Physical Sciences In partial fulfillment of requirements For the Degree of DOCTOR OF PHILOSOPHY of HOMI BHABHA NATIONAL INSTITUTE October, 2014 Homi Bhabha National Institute Recommendations of the Viva Voce Board As members of the Viva Voce Board, we certify that we have read the dissertation prepared by Vivek Singh entitled “Development of Cryogenic Bolometer for Neutrinoless Double Beta Decay in 124Sn” and recommend that it may be accepted as fulfilling the dissertation requirement for the Degree of Doctor of philosophy. Chairman - Prof. S. L. Chaplot Date: Guide / Convener - Prof. V. Nanal Date: Co-guide - Prof. V. M. Datar Date: Member - Dr. G. Ravikumar Date: Member - Prof. R. G. Pillay Date: Member - Dr. V. Ganesan Date: Final approval and acceptance of this dissertation is contingent upon the candidate’s submission of the final copies of the dissertation to HBNI. I/We hereby certify that I/we have read this dissertation prepared under my/our direction and recommend that it may be accepted as fulfilling the dissertation requirement. Date: Place: Co-guide Guide ii STATEMENT BY AUTHOR This dissertation has been submitted in partial fulfillment of requirements for an advanced degree at Homi Bhabha National Institute (HBNI) and is deposited in the Library to be made available to borrowers under rules of the HBNI. Brief quotations from this dissertation are allowable without special permission, provided that accurate acknowledgement of source is made.
    [Show full text]
  • Thz Detectors
    THz Detectors John Byrd Short Bunches in Accelerators– USPAS, Boston, MA 21-25 June 2010 Overview • Bolometers • Pyroelectric detectors • Diodes • Golay Cell Short Bunches in Accelerators– USPAS, Boston, MA 21-25 June 2010 Bolometers Bolometer: ORIGIN late 19th cent.: from Greek bolē ‘ray of light’ + -meter In 1878 Samuel Pierpont Langley invented the bolometer, a radiant-heat detector that is sensitive to differences in temperature of one hundred- thousandth of a degree Celsius (0.00001 C) . Composed of two thin strips of metal, a Wheatstone bridge, a battery, and a galvanometer (an electrical current measuring device), this instrument enabled him to study solar irradiance (light rays from the sun) far into its infrared region and to measure the intensity of solar radiation at various wavelengths. Short Bunches in Accelerators– USPAS, Boston, MA 21-25 June 2010 Bolometer principle Short Bunches in Accelerators– USPAS, Boston, MA 21-25 June 2010 Far-IR Silicon bolometer • Spectral response: 2-3000 micron • Operating temperature: 4.2-0.3 deg-K • Responds only to AC signal within detector bandwidth (may need a chopper.) Short Bunches in Accelerators– USPAS, Boston, MA 21-25 June 2010 Pyroelectric Detectors • Ferroelectric materials such as TGS or Lithium Tantalate, exhibit a large spontaneous electrical polarisation which has varies with temperature. • Observed as an electrical signal if electrodes are placed on opposite faces of a thin slice of the material to form a capacitor. • Creates a voltage across the capacitor for a high external impedance • Only sensitive to AC signals (I.e. time-varying) • Room temperature operature • Small detector area can give fast thermal response time.
    [Show full text]
  • Physics with Calorimeters
    XIII International Conference on Calorimetry in High Energy Physics (CALOR 2008) IOP Publishing Journal of Physics: Conference Series 160 (2009) 012001 doi:10.1088/1742-6596/160/1/012001 Physics with calorimeters Klaus Pretzl Laboratory of High Energy Physics, University Bern, Sidlerstr.5, CH 3012 Bern, Switzerland E-mail: pretzl@lhep,unibe,ch Abstract. Calorimeters played an essential role in the discoveries of new physics, for example neutral currents (Gargamelle), quark and gluon jets (SPEAR, UA2, UA1 and PETRA), W and Z bosons (UA1, UA2), top quark (CDF, D0) and neutrino oscillations (SUPER-KAMIOKANDE, SNO). A large variety of different calorimeters have been developed covering an energy range between several and 1020 eV. This article tries to demonstrate on a few selected examples, such as the early jet searches in hadron-hadron collisions, direct dark matter searches, neutrino-less double beta decay and direct neutrino mass measurements, how the development of these devices has allowed to explore new frontiers in physics. 1. Historical remarks The American Astronomer Samuel Pierpot Langley has 1878 invented the bolometer in order to measure the infrared radiation of celestial objects [1]. His bolometer consisted of two platinum strips one of which was thermally isolated while the other was exposed to radiation. The exposed strip could be heated due to the absorption of electromagnetic radiation and thus would change its resistance. The two strips were connected to two branches of a Wheatstone bridge which allowed to measure the resistance change of the exposed strip. Therefor a bolometer behaves like a true calorimeter which measures the absorbed energy in form of heat.
    [Show full text]
  • Uncooled Detectors for Thermal Imaging Cameras Making the Right Detector Choice
    TECHNICAL NOTE Uncooled detectors for thermal imaging cameras Making the right detector choice In the last few years thermal imaging has found its way into many more com- also exists a ferroelectric technology based on Barium Strontium Titanate mercial applications. Most of these applications require a low cost product (BST). with an uncooled detector. These sensors image in the LWIR, or longwave infrared band (7 - 14 μm). Different types of uncooled detectors are available Users of thermal imaging cameras should get the best and most modern tech- on the market. Since the infrared detector is the heart of any thermal imaging nology if they decide to purchase a system for whatever application. The ability camera, it is of the utmost importance that it is of the best possible quality. to see crystal clear pictures through darkness, fog, haze and smoke all depends on the quality of the detector. Understanding the different technologies for Uncooled detectors are made of different and often quite exotic materials uncooled detectors that are currently on the market can help in making the that each have their own benefits. Microbolometer-based detectors are either right choice. made out of Vanadium Oxide (VOx) or Amorphous Silicon (α-Si) while there Thermal imaging: The technology used at that point in time required initially developed for the military that the camera was filled with liquid nitrogen. Thermal imaging is a technology that originated The systems were extremely expensive and the in military applications. Thermal imaging cameras military had a lock on the technology because it was produce a clear image on the darkest of nights.
    [Show full text]
  • Superconducting Transition Edge Sensor Bolometer Arrays for Submillimeter Astronomy
    Superconducting Transition Edge Sensor Bolometer Arrays for Submillimeter Astronomy Dominic J. Benford, Christine A. Allen, Alexander S. Kutyrev, S. Harvey Moseley, Richard A. Shafer NASA - Goddard Space Flight Center, Code 685, Greenbelt, MD 20771 James A. Chervenak, Erich N. Grossman, Kent D. Irwin, John M. Martinis, Carl D. Reintsema NIST - Boulder, MS 814.09, Boulder, CO 80303 Abstract Studies of astrophysical emission in the far-infrared and submillimeter will increasingly require large arrays of detectors containing hundreds to thousands of elements. The last few years have seen the increasing from one to a few tens of bolometers on ground-based telescopes. A further jump of this magnitude, to a thousand bolometers, requires a fundamental redesign of the technology of making bolometer arrays. One method of achieving this increase is to design bolometers which can be packed into a rectangular array of near-unity filling factor while Nyquist-sampling the focal plane of the telescope at the operating wavelengths. In this case, the array becomes more nearly analogous to the arrays used in the near-infrared which underwent a substantial growth during the last decade. A multiplexed readout is necessary for this many detectors, and can be developed using SQUIDs such that a 32×32 array of bolometers could be read out using 100 wires rather than the >2000 needed with a brute force expansion of existing arrays. Superconducting transition edge sensors are used as the detectors for these bolometer arrays. We describe a collaborative effort currently underway at NASA/Goddard and NIST to bring about the first astronomically useful arrays of this design, containing tens of bolometers.
    [Show full text]
  • The Ultimate Detectors for Cmb Measurements
    31 BOLOMETERS : THE ULTIMATE DETECTORS FOR CMB MEASUREMENTS ? Jean-Michel Lamarre Institut d'Astrophysique Spatiale CNRS- Universite Paris-Sud, Orsay, France. Abstract The noise of an optimized bolometer depends mainly on its temperature, on its re­ quired time constant, and on the incoming power. It can be made less than the photon noise of the sky in the millimeter range provided that: ( 1) the bolometer frequency re­ sponse required by the observation strategy does not exceed a few tens of hertz; (2) the temperature of the bolometer is low enough, i.e. 0.3 Kor even 0.1 K; (3) The bandwidth of the observed radiation is large, in order to maximize the detected flux. Then, the best available bolometer technology allows photon noise limited photometry of the Cosmic Mi­ crowave Background. These conditions are met in current projects based on bolometric detection for the measurement of CMB anisotropy, and especially for COBRAS/SAMBA. The space qualification of the needed cryogenic systems has been demonstrated for 0.3 K temperatures and is in preparation for 0.1 K. For this type of wide band photometry, bolometers are the best type of detectors in the 200 µm - 5 mm wavelength range. 1 Introduction Bolometers are used in a very wide range of frequencies, fromX rays to millimeter waves. This results fromthe principle of thermal detection. Photons have only to be transformed in phonons, which is a very common process at nearly all frequencies. The temperature changes of the radiation absorber are then measured by a thermometer. Historically, the discovery of infrared radiations has been made with a simple mercury-glass thermometer used as a detector.
    [Show full text]
  • 19 International Workshop on Low Temperature Detectors
    19th International Workshop on Low Temperature Detectors Program version 1.24 - Moscow Standard Time 1 Date Time Session Monday 19 July 16:00 - 16:15 Introduction and Welcome 16:15 - 17:15 Oral O1: Devices 1 17:15 - 17:25 Break 17:25 - 18:55 Oral O1: Devices 1 (continued) 18:55 - 19:05 Break 19:05 - 20:00 Poster P1: MKIDs and TESs 1 Tuesday 20 July 16:00 - 17:15 Oral O2: Cold Readout 17:15 - 17:25 Break 17:25 - 18:55 Oral O2: Cold Readout (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P2: Readout, Other Devices, Supporting Science 1 22:00 - 23:00 Virtual Tour of NIST Quantum Sensor Group Labs Wednesday 21 July 16:00 - 17:15 Oral O3: Instruments 17:15 - 17:25 Break 17:25 - 18:55 Oral O3: Instruments (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P3: Instruments, Astrophysics and Cosmology 1 20:00 - 21:00 Vendor Exhibitor Hour Thursday 22 July 16:00 - 17:15 Oral O4A: Rare Events 1 Oral O4B: Material Analysis, Metrology, Other 17:15 - 17:25 Break 17:25 - 18:55 Oral O4A: Rare Events 1 (continued) Oral O4B: Material Analysis, Metrology, Other (continued) 18:55 - 19:05 Break 19:05 - 20:30 Poster P4: Rare Events, Materials Analysis, Metrology, Other Applications 22:00 - 23:00 Virtual Tour of NIST Cleanoom Tuesday 27 July 01:00 - 02:15 Oral O5: Devices 2 02:15 - 02:25 Break 02:25 - 03:55 Oral O5: Devices 2 (continued) 03:55 - 04:05 Break 04:05 - 05:30 Poster P5: MMCs, SNSPDs, more TESs Wednesday 28 July 01:00 - 02:15 Oral O6: Warm Readout and Supporting Science 02:15 - 02:25 Break 02:25 - 03:55 Oral O6: Warm Readout and Supporting
    [Show full text]
  • Bolometers and the CMB 1 the CMB Spectrum
    BolometersCosmic Microwave and the CMB 08/07/2017 Benson | Bolometers and the CMB 1 The CMB Spectrum 10-13 77 K • CMB is a 2.725 K blackbody Rayleigh -14 • Spectrum peaks at ~150 GHz ) 10 30 K -1 Jeans (RJ) sr -15 • Conveniently peak of CMB “tail” 15 K -1 10 spectrum is near foreground Hz -16 -2 10 minimum (i.e., dust, synchrotron) -17 and atmospheric windows I (W m 10 2.725 K 10-18 • Design detector “bands” to -19 observed within atmospheric 10 100 1000 10000 windows Freq (GHz) • Aim to design instruments where atmospheric loading dominates detector loading 08/07/2017 Benson | Bolometers and the CMB 2 Power on a Detector Power = P (⌫)d⌫ = B(⌫,T) f(⌫) A⌦ d⌫ Z Z • B(ν,T) = Blackbody equation = [ W / m2 sr Hz ] • f(ν) = Frequency response of the detector • AΩ = Throughput (or etendue) of instrument = [m2 sr] 08/07/2017 Benson | Bolometers and the CMB 3 Power on a Detector Power = P (⌫)d⌫ = B(⌫,T) f(⌫) A⌦ d⌫ Z Z • B(ν,T) = Blackbody equation = [ W / m2 sr Hz ] • f(ν) = Frequency response of the detector • AΩ = Throughput (or etendue) of instrument = [m2 sr] 2h⌫3 1 ⌫2 B(⌫,T)= 2k T c2 exp(h⌫/kT ) 1 B c2 RJ − • In RJ limit, x = hv/kT << 1 and exp(x) ~ 1 + x, greatly simplifying the black-body equation. 08/07/2017 Benson | Bolometers and the CMB 4 Power on a Detector Power = P (⌫)d⌫ = B(⌫,T) f(⌫) A⌦ d⌫ Z Z • B(ν,T) = Blackbody equation = [ W / m2 sr Hz ] • f(ν) = Frequency response of the detector • AΩ = Throughput (or etendue) of instrument = [m2 sr] • Can approximate frequency response as a band-width (Δν) times an optical efficiency (η), e.g.,
    [Show full text]