Full-Catalog.Pdf

Total Page:16

File Type:pdf, Size:1020Kb

Full-Catalog.Pdf ® Scientifi c, Inc. Instruments for Science from Scientists J-KEM Temperature Control Reaction Automation Custom Robotics J-KEM Scientifi c 2009 Product Highlights Digital Temperature Controllers Precision Temperature Controllers for Research in • Regulate volumes from 100 µL to 22 L 2009 High Power & High Safety Controllers NEW • Reactors up to 100 L • USB standard on all 200-Series temperature Economy Temperature Controllers and vacuum controllers • Free Windows control & Digital Vacuum Regulator data logging software • Digital Control of Vacuum Pressure from 760 to 0.1 torr • 0.1o C Regulation • Regulate Vacuum to 0.1 torr with DVR-1000 < 1o C Over-shoot Parallel Synthesis & Lab Automation Equipment Syringe Pumps Parallel Reaction Systems • Delivery rates from 1 µL/min • Solution phase & solid to 375 mL/min phase reaction systems • Single & Multi- • PC control of: position pumps - Reagent delivery - Temperature • PC & stand - Pressure alone operation • Custom designs • Deliver any volume from any syringe Reaction Block Systems • KEM-Lab Personal Reaction Blocks • Heat, cool, & refl ux • Multiple vial sizes • Custom designs • Multiple Temperature Zones Custom Robotic Workstations Robotic Solutions • Custom hardware and software • Weighing • Dissolution • Reformatting • Solid & Solution phase Synthesis • Cherry picking • Solid phase extraction User Programmable • All robots include the original source code - Endeavour Robots NEW Capping/Uncapping priced from $6000 Station Index Adapters, Thermocouple 39 Personal Reaction Station 16 Temperature Controllers Automation Equipment Pressure Regulator, Digital 31 Research Controllers 32-37 Robotics 2-9 Reaction Blocks Multi-Channel 34 Fluid Delivery 10-15 Single Temperature Zone 18 Safety 35 Reactors 14-15, 25 Multi-Temperature Zone 22 High Power 35 Chiller, Circulating 24 Custom 20-21 Oil Bath Controller 36 Evaporators Shaker 19 Economy 36 KEM-Vap 27 Reaction Controller 14 Custom 25 Microtiter Plate 23, 27 Robotics Monitors 28 Reaction Block 18 Instruments 2-7 Safety Limit Controller 28 Custom 27 Accessories 8-9 Power Controller 29 Fraction Collector 9 Do-It-Yourself 7 Thermocouples & Accessories 38-39 Gas Heater 29 Safety Equipment Temperature Monitor 28 Glass Microtiter Plate 23 Lab Safety Controller 28 Thermocouples Heating Mantles 40 Water Flow Monitor 28 Single Element 38-39 Hand-Held Meters 29 Digital Temperature Monitor 28 Dual Element 35 KEM-Lab Reactors 23 Temperature Controllers 35 Glass Coated 38 KEM-Prep Reactor 17 Shakers Tefl on Coated 38-39 KEM-Vap Evaporator 27 Benchtop, Reaction Block 19 Hypodermic Needle Probe 39 Monitors KEM-Lab 23 Thin Wire 39 Temperature 28 Robotic 8 Cords and Accessories 38 Vacuum 30 Solid Phase Extraction Station 8 Trinity Power Controller 29 Water Flow 28 Solid Phase Synthesis Reactor 26 USB Network Extenders 37 Nitrogen Gas Heater 29 Solvent Evaporator 27 Vacuum Regulator, Digital 30 Oil baths, Instatherm 40 Stirrer, Miniature Overhead 25 Monitors 30 Over-Head Stirrer 25 Syringe Pump Precision 31 Parallel Synthesis Reactors Single and Multi-Channel 10-13 Variac, Solid State 29 Solution Phase 15-23 Custom 11-14 Water Flow Monitor 28 Solid Phase 26 Do-It-Yourself 11 Who We Are 41 Heating Profi le of J-KEM’s Temperature Control 200-Series Temperature Controllers J-KEM’s patented power control computer makes this the only controller that can heat volumes under 100 µL with the safety of 0.1o C regulation. Actual heating data is shown at right. Model 210 controller shown with power control computer Ordering Information The J-KEM® Guarantee All J-KEM products are guaranteed to be the highest quality and most accurate instruments available. Any J-KEM product ® not meeting your expectations can be J-KEM Scientifi c, Inc. returned within 30 days for a full refund. Phone: (314) 863-5536 Robert C. Elliott / President J-KEM Scientifi c, Inc. (800) 827-4849 6970 Olive Blvd. FAX: (314) 863-6070 Saint Louis, MO 63130 Email: [email protected] USA On-line Catalog: http://www.jkem.com Custom Laboratory Robotics Eclipse With four robot styles and multiple software options, J-KEM is Workstation uniquely positioned to offer custom robotic solutions for virtually any lab automation need. J-KEM’s technology makes lab automation as Simple as 1, 2, 3. 1 Four Robotic Platforms to Choose From Key Features: • Fast • Positional accuracy • Affordable • Multiple Z-probes With four different robotic platforms, J-KEM can select the one that most effi ciently automates your unique application. Each platform has its own set of advantages including speed, positional accuracy, power, Phoenix Workstation and price that make it the preferred system for different applications. Key Features: • Large deck size • Multiple Z-probes 2 Custom Solutions • Generates > 100 lb. of force in the Z- direction. J-KEM offers complete hardware and software solutions for almost any Voyager lab automation task. Every workstation is customized with the features Workstation and software needed to run your specifi c application. Workstations for: • Weighing • Dissolution • Synthesis • Sorting • Crystallization • Cherry picking • SPE • SPS • Spectroscopy Key Features: • Fast • Optimized for microvial weighing and cherry picking applications 3 Do-It-Yourself Robotics Endeavour Workstation New in 2009 J-KEM offers each of its robotic systems with custom programming, professional installation, and user training. For most researchers, this is the service they both need and expect. For those research teams who prefer to do it themselves, J-KEM now offers each of its robotic systems as a fully confi gured and tested workstation, but with no pre-installed software. With complete systems starting under $6,000, this is a highly affordable way to introduce robotics to your workfl ow. Software options are available to support your custom development. Key Features: • Fast • Positional accuracy • Most affordable workstation available Page 2 J-KEM Scientifi c Toll-free: (800) 827-4849 Fax: (314) 863-6070 www.jkem.com [email protected] Eclipse Robotic Workstations The Eclipse workstation uses modular X- and Y-axis rails combined with a Value: From $20,000 wide selection of automated tools such as grippers, multi-position needles, and custom probes. The open design of the Eclipse provides easy access to the entire workstation deck. Affordability: The affordable price of the Eclipse (starting under $20,000) creates new opportunities for lab automation. For example, a weighing station with bar code scanner and 0.01 mg resolution balance costs about $28,000. Features: • Speed: 400 mm/sec • Positional Accuracy: ±0.02mm • Z-Axis Force: 10 pounds Examples of Eclipse Workstations Test Tube • Bar code scanner • Analytical balance Plate Washer with Weighing Station • Excel output Heated Reaction Station See the Eclipse in action at: www.jkem.com/robotics • Multi-step synthesis program run in micro titer plate cells • Plate gripper Solid Phase • Temperature controlled reactor Extraction Station • 24 Columns developed in parallel • Controls fl ow rate in all columns • Solvent level in each column is optically monitored to stop solvent fl ow when the solvent front reaches the top of the packing. Derivatization Station Spectroscopy Robot • Automated spectroscopic • Reagent addition to septum vials analysis of 200 samples • Heated reactor with mixing • Reaction mixture sampled at user set times to GC vials J-KEM Scientifi c Toll-free: (800) 827-4849 Fax: (314) 863-6070 www.jkem.com [email protected] Page 3 Advantages of J-KEM Robotics Custom Design While others start from an existing design, then try to make your application fi t their instrument, every J-KEM workstation is designed from scratch to implement your automation task effi ciently and with an eye towards future expandability. J-KEM’s experience in lab automation, including temperature control, reactor design, fl uid delivery, solid and solution phase synthesis is invaluable when optimizing the design of custom robotics. Polymer Compounding Robot Modules: 4-Temperaure zone reaction block, balance, bar code reader, heated & cooled reagent block, cooled 4-position sonicator, precision syringe pump with 16 reagent ports, 6-zone temperature controller, and needle wash station. Custom Software You Own the Solution Custom software is written for every workstation to provide an J-KEM believes that you should not only own the instrument, but you intuitive user interface. The procedure’s setup, the way data is read should own the technology that created the instrument. That’s why into and out of the program, and the exact sequence of program steps we are the only company that releases the original source code with are all customized to make the operation of your robot both effi cient every robot. This gives you the power to change every aspect of the and user friendly. robot’s operation as your automation needs change. Personal Service J-KEM is committed to personal service, offering any support that’s needed to assure the successful integration and productivity of our automation solutions. With one phone call, you can talk to the engineer who designed your robot, the engineer who installed it, and the software engineer who wrote the program. Value J-KEM’s custom robotics are often half the price of other companies’ “one-size-fi ts-all” alternative. While many of the modules on a workstation are standard J-KEM products, we also use the best available instruments like balances, bar code readers, and pumps to assemble the fi nal workstation in the most affordable and effi cient Why is it important to own the original source code? manner. Without the source code, you’re stuck with the robot you have It’s not really enough to own the code if it’s not easy to use. rather than the robot you need as your automation needs change. For example, suppose the robot’s original task was weighing and Written in VB.Net, the robotic For Vial = 1 to 96 dissolving samples to specifi c concentrations, but now you need it to software contains intuitive, Rack.MoveToCell(XY, Vial) add reagents to 4 mL septum vials in a temperature controlled reactor high level functions that make Gripper.PickUpVial() with mixing.
Recommended publications
  • Science Equipment
    Block Heaters with BioCote Science Equipment Colony Counter Homogenisers ® Hotplates and Stirrers protection antimicrobial Incubators Melting Point Apparatus Stuart Mixers ® Catalogue Rotary Evaporators Rockers and Shakers Water Baths and Purification Page 1 Bibby Scientific Limited Some of the most famous names in science... As one of the largest broad based manufacturers of benchtop laboratory equipment worldwide, Bibby Scientific Ltd provides internationally recognised brands with reputations for product quality and high performance. These four famous brands are now brought together in a single package to offer an excellent level of quality, service and support. Electrothermal® are the newest addition to the Bibby Scientific portfolio and are market leaders in heating mantle design and manufacture. The extensive Electrothermal® range includes controlled, stirring, Bunsen and spill-proof mantles in various shapes and capacities. Alongside the heating mantle range, Electrothermal® offer an extensive selection of stirrers and melting point apparatus. Jenway® manufactures a wide range of analytical scientific instruments including UV/Vis spectrophotometers, flame photometers, colorimeters, portable and laboratory meters for the measurement of dissolved oxygen, pH, conductivity and specific ions. The extensive Stuart® range includes blood tube rotators, colony counters, hotplates, hybridisation ovens, rockers, shakers, stirrers and water purification systems. Techne® is a world leader in the manufacture of temperature control equipment,
    [Show full text]
  • Heating Mantles - Series TM Mantles
    Glas-Col, LLC General Sales Policy How To Order Restock You can order by contacting one of the many authorized Glas-Col Current models of catalog items returned for credit are subject to distributors located throughout the U.S.A., Canada, and around the Glas-Col’s inspection and a restocking charge of 15% of the original world. They will offer valuable assistance in your selections, delivery purchase price. Items superseded by current models cannot be and service after the sale. Please use our toll-free telephone number, returned for credit. Special, custom-designed items or catalog items 1-800-Glas-Col, if you need the name of a distributor in your area. modified for special voltage, wattage, dimensions, etc., will not be accepted for credit. New Accounts When restock is necessary due to a Glas-Col error in fulfilling an order, full credit will be given immediately upon receipt of the With approved credit, new direct accounts will be opened for order merchandise in question. amounts of $100 net or more. Orders for less than $100 may be prepaid, shipped COD, or paid by Visa, MasterCard, or American Purchaser should not deduct credit until merchandise is received, Express inspected, and a credit memo issued by Glas-Col. Terms Of Payment Inspection/Repair Service Upon approved credit, billing terms are Net 30 days. Otherwise, Glas-Col does not support or authorize any repairs outside of the arrangements may be made for Visa, MasterCard, American Express, factory. Products returned for repair not covered under warranty will advance payment, or COD. Invoices are payable in U.S.
    [Show full text]
  • Heating Mantles
    HEATING MANTLES 17-1000: STIRMANTLE The StirMantle adds electromagnetic stirring capability (50-750 rpm) to the Series TM heating mantle for spherical flasks. Heating and stirring are independent; choose either or both. Speed is easily adjusted by a single dial on the StirControl II. The StirControl II creates and synchronizes the magnetic field. Its stirring speed is extremely stable, even at 50 rpm, despite temperature or load. When restarting (as for removal and reinsertion of the flask), Glas-Col's exclusive "Synchrostart" feature maintains linkage between the field and the bar. At restart, the selected speed is reached in approximately 4 seconds. The StirControl II connects to the StirMantle by cord, so it may be placed outside corrosive hood atmospheres and is easily accessible. Complete Complete StirMantle StirMantle Flask Outside Depth Height System System Only Only Capacity Watts Diameter (in) (in) 115V 230V 115V 230V (ml) (in) 100D 100D 100D 100D 250 180 1.64 6.25 4.75 EMS102 EMS103 TEM102 TEM103 100D 100D 100D 100D 300 180 1.70 6.25 4.75 EMS104 EMS105 TEM104 TEM105 100D 100D 100D 100D 500 270 2.00 6.25 5.25 EMS106 EMS107 TEM106 TEM107 100D 100D 100D 100D 1,000 380 2.56 7.50 5.50 EMS108 EMS109 TEM108 TEM109 100D 100D 100D 100D 2,000 500 3.35 10.00 6.50 EMS110 EMS111 TEM110 TEM111 100D 100D 100D 100D 3,000 500 3.60 10.00 6.50 EMS112 EMS113 TEM112 TEM113 Specifications Complete System: One StirMantle, one StirControl II, connecting cords, and stir bar. Completely grounded and fused.
    [Show full text]
  • Heating Mantles
    SELECTION GUIDE Heating Mantles OUR SELF-SUPPORTED CLOTH- SPILL-PROOF AND V-SHAPED ONE MANTLE—THREE SIZES! MULTI-POSITION HEATERS! JACKETED HEATING MANTLE! HEATING MANTLES! BASIC HEATING MANTLES Product Description Case Construction Built-In Controller Page HOTTEST SELLING COOL CASE HEATING MANTLES! Basic EM Series Polypropylene With/Without 100 TOP OF THE LINE METAL CASE MANTLES! Basic CM, CMU and UM Series Aluminum With/Without 104-106, 109 SO FLEXIBLE IT CAN BE USED FOR ROUND AND FLAT BOTTOM FLASKS! Basic MG Series Mesh No 110 COMPACT, ECONOMICAL CLOTH-JACKETED HEATING MANTLE! Basic HM Series Fiberglass No 111-112 MULTI-POSITION HEATERS! Basic EME and 5000 Series Aluminum With/Without 114-116 SPILL-PROOF HEATING MANTLES SPILL-PROOF AND V-SHAPED HEATING MANTLES! Basic Spill-proof EMX Series Polypropylene Yes 102 V-SHAPED HEATING MANTLES SPILL-PROOF AND V-SHAPED HEATING MANTLES! Basic EMV Series Polypropylene Yes 102 NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLE! Basic CMUV and CMV Series Aluminum With/Without 104-106 HEATING-STIRRING HEATING MANTLES HEAT AND STIR COOL CASE HEATING MANTLE! Heat-Stir EMA Series Polypropylene Yes 103 NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLES! Heat-Stir CMUA Series Aluminum No 104 OUR MODULAR HEATING MANTLE! Heat-Stir OM Series Aluminum Yes 108 MULTI-POSITION HEATERS! Heat-Stir EMEA Series Aluminum Yes 114 HIGH TEMPERATURE/RETORT BOTTOM HEATING MANTLES NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLES! CMUH and CMUR Series Aluminum No 104 VARIABLE SIZED HEATING MANTLES TOP OF THE
    [Show full text]
  • Organic Techniques
    ORGANIC TECHNIQUES Organic techniques Introduction Practical organic chemistry is primarily concerned with synthesising (making) organic compounds and the purpose of a ‘synthesis’ is to prepare a pure sample of a specified compound. Essentially, there are five steps involved: • preparation – the appropriate reaction is carried out and a crude sample of the desired product is prepared • isolation – the crude sample of the product is separated from the reaction mixture • purification – the crude product is purified • identification – the identity of the pure compound is confirmed • calculation of the percentage yield. Apart from the last, each of the steps entails a variety of experimental techniques and operations, and in what follows some of the more important ones will be described. While they will be considered from a practical standpoint, we will touch on their theoretical basis where appropriate. Preparation Most organic preparations are carried out in fairly complex assemblies of glassware. The glassware has ground-glass joints that allow the individual pieces to fit together tightly, thus eliminating any need for corks or rubber stoppers. Suppose we had to prepare a compound that required the reactants to be heated, which is generally the case in organic chemistry. Let’s look at the glassware needed. It is illustrated below and consists of a round-bottomed or pear-shaped flask and a condenser. 26 A PRACTICAL GUIDE (AH, CHEMISTRY) © Crown copyright 2012 ORGANIC TECHNIQUES The assembled apparatus is shown below with the condenser mounted vertically above the reaction flask. The reaction flask should be of a size such that when the reactants are in place it is about half full.
    [Show full text]
  • Heating and Cooling Chemical Mixtures Revision Date: 11/01/19 Prepared By: Michael Roy P.I.: Prof
    Section 5.7 Title: Heating and Cooling Chemical Mixtures Revision Date: 11/01/19 Prepared By: Michael Roy P.I.: Prof. John F. Berry Prior Approval: This procedure is NOT considered hazardous enough that prior approval is needed from the Principal Investigator. Involves Use of Particularly Hazardous Substance (PHS)? No ___ Carcinogen ___ Reproductive Toxin ___ High Acute Toxicity Does this procedure require medical surveillance? No Does this require use of a fit-tested respirator? No Brief Description of Procedure: Overview of common heating and cooling methods used in the Berry labs. Location: List the locations (buildings/rooms) where this procedure may be performed. For use of a PHS indicate a more precise location within the room, if appropriate, as a designated area. Daniels Chemistry - All Berry group labs Chemicals Involved: Chemical Physical or Health Hazard (e.g. carcinogen, corrosive) Organic solvents (cooling) Consult relevant SDSs for more details Dry ice Frostbite Liquid nitrogen Frostbite, asphyxiation Other Hazards: Include hazards, other than chemical, that may be present during operation of the procedure. Burns (heating) and frostbite (cooling). Exposure Controls: (Check all that apply) PPE: _X_ Safety Glasses ___ Face Shield ___Chemical Splash Goggles ___Chemical Apron _X_ Gloves (Nitrile) _X_ Lab Coat ___Respirator (type) ___Other: Engineering Controls: _X_ Fume Hood ___Biosafety Cabinet ___ Glove box ___ Vented gas cabinet ___Other: Administrative Controls: List any specific work practices needed to perform this procedure (e.g., cannot be performed alone, must notify other staff members before beginning, etc.). N/A Task Hazard Control Table: For procedures involving numerous steps, it may be convenient to indicate specific requirements for individual tasks in the table below: N/A Waste Disposal: Describe any chemical waste generated and the disposal method used.
    [Show full text]
  • Paint Testing Table of Contents
    Paint Testing Table of Contents Abrasion Testers ............................................................. 3 Leveling Test Blade ....................................................... 29 Anemometers ................................................................. 3 Liquid Color Meter ........................................................ 29 Applicators ....................................................................... 4-6 Lubricating Grease ........................................................ 30 Aprons ............................................................................... 6 Micro Grinder .................................................................. 30 Aquametry Titration Units .......................................... 6 Moisture Pans ................................................................. 30 Balances ............................................................................ 6-7 Paint Test Charts............................................................. 30-31 Barometer ........................................................................ 7 Paint Thermometers ..................................................... 31 Beakers .............................................................................. 7-9 pH Buffers ......................................................................... 31-32 Bottles ................................................................................ 9-12 pH Electrodes .................................................................. 32 Brushes .............................................................................
    [Show full text]
  • Chemistry 59-240
    CHEMISTRY 59-240 PHYSICAL CHEMISTRY LABORATORY MANUAL FALL 2010 10th Edition - Version 1.3 DEPARTMENT OF CHEMISTRY & BIOCHEMISTRY UNIVERSITY OF WINDSOR 0 TABLE OF CONTENTS GENERAL INSTRUCTIONS Emergency Procedures............................................................................................................ 3 Safety Regulations & Quiz....................................................................................................... 9 Policy on Plagiarism................................................................................................................ 21 Student Contract...................................................................................................................... 25 Marking Scheme and Outline................................................................................................. 27 Medical Certificate .................................................................................................................. 31 EXPERIMENTS Experiment 1: Determination of ΔcH: Bomb Calorimetry.......................................................... 33 Experiment 2: Vapour Pressure of Pure Liquids....................................................................... 41 Experiment 3: Surface Tension of n-Butanol and Amount Adsorbed....................................... 49 Experiment 4: Heat of Reaction in Solution: Constant Pressure Calorimeter.......................... 55 Experiment 5: Liquid-Vapour Equilibrium in a Binary System.................................................. 59
    [Show full text]
  • Equipment Safety Doc
    Equipment Safety Doc. No. IITB/ISG/01/Rev.0 Introduction Some of the hazards related with equipment used in research labs include Electrical hazards Hot surface which can cause burns and which can be a source of ignition. High noise levels Unguarded rotating parts Use of vacuum which can cause implosion. Use of high pressure Generation of magnetic fields Ultra violet and infra red radiation Many accidents in research laboratories result from improper use and lack of maintenance of equipment. The following precautions must be adopted while working with equipment in the laboratory. Refer the operating manual/user manual of the equipment before starting operation. The manual will contain details of hazards and safety precautions to be taken during installation, operation and maintenance. The operating manuals of equipment must be located at an easily accessible location in the laboratory. Personnel who are not authorised and trained must not carry out operation of the equipment. New users must carry out the operation under guidance of senior research scholars. A schedule for maintenance and inspection of equipment must be prepared as per manufacturer’s instruction and must be adhered to. Unauthorised maintenance activity must not be done. Service personnel must be contacted where required. Switch off and unplug the equipment while making adjustments. Switch off the equipment at the end of the operation and when not in use. Page 1 of 9 Equipment Safety Doc. No. IITB/ISG/01/Rev.0 Use personal protective equipment as recommended by the manufacturer while operating the equipment. Equipment with specific hazards must not be left unattended.
    [Show full text]
  • 1 Experiment 3. Heat-Capacity Ratios for Gases. Adiabatic Expansion
    Experiment 3. Heat-Capacity Ratios for Gases. Adiabatic Expansion Method Background For the reversible adiabatic expansion of a perfect gas, the change in energy content is related to the change in volume by nRT dE = − pdV = − dV = −nRTd lnV (4) V Since E for a perfect gas is a function of temperature only, we can also write dE = CvdT. Substituting this expression into Eq. (4) and integrating, we find that ~ ~ T2 V2 Cv ln = −R ln ~ (5) T1 V1 ~ ~ where Cv and V are molar quantities (that is, Cv/n, V/n). We assumed here that Cv is constant over the temperature range involved. Eq. (5) predicts the decrease in temperature resulting from reversible adiabatic expansion of a perfect gas. In experiment, we will use the following two-step process involving a perfect gas denoted by A: Step I: Allow the gas to expand adiabatically and reversibly until the pressure has dropped from p1 to p2: ~ ~ A(p1 ,V1 ,T1 )→ A(p2 ,V2 ,T2 ) (6) Step II: At constant volume, restore the temperature of the gas to T1: ~ ~ A(p2 ,V2 ,T2 )→ A(p3 ,V2 ,T1 ) (7) For step I, we can use the perfect-gas law to obtain ~ T2 p2V2 = ~ (8) T1 p1V1 ~ ~ Substituting Eq. (8) into Eq. (5) and combining terms in V2 V1 , we can write ~ ~ ~ C ~ p2 − (Cv + R) V2 p V2 ln = ~ ln ~ = − ~ ln ~ (9) p1 Cv V1 Cv V1 since for a perfect gas ~ ~ C p = Cv + R (10) 1 For step II, which restores the temperature to T1, ~ V2 p1 ~ = (11) V1 p3 Thus ~ p1 C p p1 ln = ~ ln (12) p2 Cv p3 This can be rewritten in the form ~ C p ln(p1 p2 ) γ ≡ ~ = (13) Cv ln(p1 p3 ) The goal of our experiment is to obtain γ for two gases, N2 and Ar, through measurements of p1, p2, and p3.
    [Show full text]
  • Safety in Academic Chemistry Laboratories
    Safety in Academic Chemistry Laboratories 8TH EDITION BEST PRACTICES FOR FIRST- AND SECOND-YEAR UNIVERSITY STUDENTS A Publication of the American Chemical Society Joint Board–Council Committee on Chemical Safety CHAPTER 4 Recommended Laboratory Techniques Introduction Chapter 3 described some types of physical, health, and environmental chemical hazards and the effects of being exposed to chemicals. The focus of this chapter is on how to safely perform common laboratory techniques and safely handle the most common equipment in the undergraduate chemistry laboratory. The techniques and advice in this booklet focus on those topics most commonly encountered in first- and second-year courses in college. There is brief mention of some advanced topics that you may encounter in upper-level courses in the “In Your Future” sidebars, Hierarchy but a thorough presentation of MOST EFFECTIVEElimination/ advanced techniques is beyond Substitution of Controls the scope of this publication. Requires a physical The references in the Appendix Engineering Controls change to the point to other sources of safety workplace information. Administrative Controls Requires worker As discussed in Chapter 1, or employer to the RAMP system is a useful including Work Practices do something paradigm when you work in the laboratory. Chemical safety Requires workers Personal Protective Equipment to wear something must be the priority of everyone. LEAST EFFECTIVE Apply the RAMP concept as 46 CHAPTER 4 you prepare for each laboratory session. Once hazards have I been recognized and assessed, they must be minimized or Hierarchy of Controls Recommended managed. Minimizing hazards to reduce risk involves adding Elimination: the initial design of controls or placing barriers between the worker and the the facility, equipment, chemicals, or process to remove hazards.
    [Show full text]
  • Jenway Catalogue 2012
    Double Beam Spectrophotometers Equipment forAnalysis Life Science Spectrophotometers UV/Visible Spectrophotometers pH Meters Ion Meters Flame Photometers Fluorimeters Dissolved Oxygen Meters Conductivity Meters Colourimeters Bibby Scientific Limited Some of the most famous names in science... As one of the largest broad based manufacturers of benchtop laboratory equipment worldwide, Bibby Scientific Ltd provides internationally recognised brands with reputations for product quality and high performance. These four famous brands are now brought together in a single package to offer an excellent level of quality, service and support. A Bibby Scientific Company Electrothermal are the newest addition to the Bibby Scientific portfolio and are market leaders in heating mantle design and manufacture. The extensive Electrothermal range includes controlled, stirring, Bunsen and spill-proof mantles in various shapes and capacities. Alongside the heating mantle range, Electrothermal offer an extensive selection of stirrers and melting point apparatus. Jenway® manufactures a wide range of analytical scientific instruments including UV/Vis spectrophotometers, flame photometers, colorimeters, portable and laboratory meters for the measurement of dissolved oxygen, pH, conductivity and specific ions. The extensive Stuart® range includes blood tube rotators, colony counters, hotplates, hybridisation ovens, rockers, shakers, stirrers and water purification systems. Techne® is a world leader in the manufacture of temperature control equipment, including
    [Show full text]