Unit 1 Introducing Scientific Apparatus

Total Page:16

File Type:pdf, Size:1020Kb

Unit 1 Introducing Scientific Apparatus UNIT 1 INTRODUCING SCIENTIFIC APPARATUS Structure Introduction Objectives Identification of Apparatus Apparatus for Heating Bunsen Burner Air Bath Water Bath Oil Bath Sand Bath Hot Plate Heating Mantle Heating Block Immersion Heater Laboratory Glassware Jointed Glassware Setting up Demonstrations Selecting the Apparatus Setting up the Apparatus Laboratory Centrifuge Use and Description Rotor Heads Advantages and Disadvantages Summary Tenninal Questions Answers 1.1 INTRODUCTION This unit has been designed to introduce you to scientific apparatus with which you will be involved in laboratory work. This unit can be divided into two parts: The first part deals with identification, use and basic maintenance of common pieces of laboratory apparatus and equipments. The second part helps you to apply this knowledge by dealing with selection and setting up of apparatus for common kinds of experiments. Since cleaning and maintenance are dealt with at some length in Unit 3, this unit simply outlines the basic maintenance techniques required for you to use the apparatus straight away, in a professional manner and without causing any damage. Objectives After studying this unit, you should be able to: identify and name common pieces of apparatus, select the most appropriate apparatus for a given experiment and give reasons for the choice, state why glass is such a useful material in the laboratory and how to clean and care for specific items, Laboratory Apparatus and Equipments state and demonstrate how to use common pieces of apparatus safely and correctly, explain how to support apparatus correctly, select the apparatus needed for a simple distillation and state how it should be assembled, describe the working of centrifuge, 1.2 IDENTIFICATION OF APPARATUS The first stage in identification of apparatus is to make sure that you call pieces of apparatus by the same (correct) name as everyone else involved in scientific work. Given below is a list of common laboratory apparatus. We strongly advise you to read through this list as there will be all kinds of tit-bits of information provided that you'll need to know. Diagrams of the apparatus are given in Appendix I. Absorption tower - This is used to dry gases when a solid drying agent is being used. Aspirator - Plastic ones are probably more useful than glass, but the plastic taps can leak. Beware of this if you are keeping corrosive substances in them. When draining a liquid from an aspirator, through the tap, you will need to loosen the caplstopper. Beaker - What would laboratory life be like without beakers? Of course, beakers that you provide for use should be sound. Discard any that are chipped (unless you can flame-polish the chip) and, most certainly, any that are cracked. Beehive shelf - This is used to support a gas jar when a gas is being collected over water. Bell jars - The open type needs a ground - glass stopper which should be lightly greased. Boiling tube Bosshead - This diagram is actually the wrong way round, for correct use. It is mechanically more stable if the bosshead is screwed to the retort rod with the gap away from you so that the clamp rests on top of the other jaw. Buchner funnel - This is used, mainly in organic chemistry, for collecting precipitates and filtering under reduced pressure. It is used with a small filter paper. Sintered glass Buchner funnels of different porosities are also available. Bunsen burner - Bunsen burner is the most common means of heating in the lab Bunsen burners should be checked for serviceability at least once a year. The following is a recommended maintenance checklist. (a) Unscrew the chimney and ensyre that the hole is clear. (b) A smudge of petroleum jelly' aroufid the thread will ensure that the chimney can be refitted easily. (c) Make sure that the collar Wseasily. To overcome some peoples' tendency to remove the rubber tubing to use for other purposes, you might like to wire the tubing onto the burner's gas inlet tube. (d) Check the rubber tubing for splits, etc. frequently and replace it if it is showing signs of wear. Plastic tubing should not be used as it can easily be melted or softened and distorted when the Introducing Scientific Bunsen burners are put away. Apparatus Bunsen burners are available both for use with natural (mains) gas and with bottled gases. Do not mix up the different types of burners, as they are not interchangeable. (Bunsen burners for use with bottled gases, have larger holes at the base of the chimney for tile gas to pass through.) Bunsen screw or Hofmann clip - This is called to adjust the flow rate of a liquid, usually water, through a piece of flexible tubing. Burette - A burette is a glass tube fitted to a tap. This is discussed in more detail in Unit 2. Burette stands - This can also be used as a funnel stand. Ceramic gauze - These used to contain asbestos, in place of the ceramic, but any asbestos gauze should have been discarded long ago. The gauze's purpose is to diffuse the heat provided by a Bunsen burner so that the vessel being heated does not suffer from thermal shock. If the ceramic is missing from parts of the mesh in the center of the gauze, the gauze should be discarded. Stainless steel gauze without the ceramic center can also be used. Combustion boat - This is used to hold a powder, which is then heated, in a stream of gas in a combustion tube. Combustion boats are made of silica or porcelain. Conical beakers - These are often used in gravimetric analysis or in the preparation of compounds in chemistry. Conical flask - This belongs alongside the beaker and the test-tube as a comer stone of practical science. Cork borers - It is used to bore a smooth hole of desired size in a cork. Cork borer sharpener Crucible and lid - Crucibles are used for heating a dry substance strongly and they are usually made of porcelain. As a result of the high temperatures at which they are used, crucibles are liable to break and may be difficult to clean. You should always check for hairline cracks before use. The easiest way to do this is to turn the crucible upside down on a wooden bench; lift one side about 5 mrn above the bench and let it drop back. A "flat" sound indicates a crack - which may be too fine to see but which would cause the crucible to shatter when heated. Crucibles and lids can also be made of silica, nickel and platinum. Crucible tongs Deflagrating spoon -This is used to support substances that are to react with gases contained in gas jars. Desiccators - Desiccators are used to remove the last traces of moisture from apparatus or substances and to keep them dry. Placing them on the wire rack over a desiccant -a substance that readily absorbs water, dries objects. The most common desiccant is ankjdrous calcium chloride but others are also used. The ground-glass rims of the lid and the base should be lightly greased and the lid slide about to spread the grease to give an airtight seal. When placing something hot in a desiccator, beware of pressure building up inside because it can'blow the lid off (and onto the floor)! Either leave the lid ajar or open the tap Laboratory Apparatus and Equipment. until the object has cooled. When removing the lid, SLIDE it across the base. Do not try to lift it off - many back injuries have been caused in this way. Distillation flask -Its name tells its use. It is often used with condenser (item 36). Drechsel bottle - Note the spelling. This is used to wash or dry gases and as a device to prevent suck back. Dropping funnel - This is used for adding a liquid to a reaction mixture. Evaporating basin - These are available in glass or porcelain. Porcelain basins are liable to crack when heated strongly, like crucibles, and they should be checked for integrity before use, in the same way as crucibles. Filter flask -The side arm is connected to a vacuum pump or a filter pump. It is often used in conjunction with Buchner funnel (item 8). If it has a ground glass neck, it is known as a Buchner flask (but its purpose is the same). Filter pumps - This type of pump is attached to a cold water tap, which when turned on, creates a partial vacuum. Always ensure that the broader end of the pump is connected to the water supply. Flat-bottomed flask - This type of flask should not be heated or subjected to pressure changes as the glass is under stress around the flat bottom. Funnel - This is used for ordinary filtration by gravity, in conjunction with a filter paper. Gas jar. Gooch crucible -These are used in gravimetric chemical analysis for the collection and drying of inorganic products. The sintered glass discs are available in a range of porosities - the higher the number, the smaller the pore size, the finer the particle that can be retained and the slower the filtration. Hand lens - This is best used by holding it close to the eye. The object being examined is then brought up to the lens and hence into focus. Hydrometer - This is used to measure the relative density of a liquid. Lab jack - This is much better than a pile of books, or even a brick or two, to support apparatus. It has a hole drilled in one comer so that a retort rod can be fitted. Liebig condenser - Note the spelling. When using this condenser, water is fed into the outer jacket via the connection near the condenser's outlet.
Recommended publications
  • Performance Validation of the Microbiologique Microfilm Test
    MAI ET AL.: JOURNAL OF AOAC INTERNATIONAL VOL. 101, NO. X, 2018 1 FOOD BIOLOGICAL CONTAMINANTS Performance Validation of the Microbiologique MicrofilmTM Test System for AOAC Research Institute Performance Tested Method SMCertification AOAC Performance Tested Method SM 051702 Abstract ANNA SHAPOVALOVA and HARISH K. JANAGAMA Molecular Epidemiology, Inc., 15300 Bothell Way NE, The Microfilm™ Test System is intended for quantitative Lake Forest Park, WA 98155 microbiology and consists of three types of Microfilms for aerobic LONG VUONG and ALEX FRIEDRICH plate count (Microfilm APC), total coliform and Escherichia coli IEH Laboratories and Consulting Group, Inc., 15300 Bothell count (Microfilm TCEc), and yeast and mold count (Microfilm Way NE, Lake Forest Park, WA 98155 YMC). This study evaluated the performance of the Microfilm DYLAN JOHNSON Test System against International Organization for Standardization Molecular Epidemiology, Inc., 15300 Bothell Way NE, (ISO) methods on 20 food matrixes and 2 environmental surfaces. Lake Forest Park, WA 98155 Ruggedness, robustness, and stability were also determined, LOURDES M. NADALA while inclusivity and exclusivity studies were performed on Molecular Epidemiology, Inc., 15300 Bothell Way N.E., Microfilm TCEc and YMC. An independent laboratory evaluated Lake Forest Park, WA 98155; Microbiologique, the performance on four food matrixes and one environmental Inc., 8215 Lake City Way NE, Seattle, WA 98115 surface. No significant differences and high correlation coefficients VAN NGUYEN were observed between the Microfilm Test System and the Microbiologique, Inc., 8215 Lake City Way NE, Seattle, corresponding ISO methods (ISO 4833-1:2013 for APC, ISO WA 98115 4832:2006 for total coliform count, ISO 16649-2: 2001 for E.
    [Show full text]
  • Science Equipment
    Block Heaters with BioCote Science Equipment Colony Counter Homogenisers ® Hotplates and Stirrers protection antimicrobial Incubators Melting Point Apparatus Stuart Mixers ® Catalogue Rotary Evaporators Rockers and Shakers Water Baths and Purification Page 1 Bibby Scientific Limited Some of the most famous names in science... As one of the largest broad based manufacturers of benchtop laboratory equipment worldwide, Bibby Scientific Ltd provides internationally recognised brands with reputations for product quality and high performance. These four famous brands are now brought together in a single package to offer an excellent level of quality, service and support. Electrothermal® are the newest addition to the Bibby Scientific portfolio and are market leaders in heating mantle design and manufacture. The extensive Electrothermal® range includes controlled, stirring, Bunsen and spill-proof mantles in various shapes and capacities. Alongside the heating mantle range, Electrothermal® offer an extensive selection of stirrers and melting point apparatus. Jenway® manufactures a wide range of analytical scientific instruments including UV/Vis spectrophotometers, flame photometers, colorimeters, portable and laboratory meters for the measurement of dissolved oxygen, pH, conductivity and specific ions. The extensive Stuart® range includes blood tube rotators, colony counters, hotplates, hybridisation ovens, rockers, shakers, stirrers and water purification systems. Techne® is a world leader in the manufacture of temperature control equipment,
    [Show full text]
  • Heating Mantles - Series TM Mantles
    Glas-Col, LLC General Sales Policy How To Order Restock You can order by contacting one of the many authorized Glas-Col Current models of catalog items returned for credit are subject to distributors located throughout the U.S.A., Canada, and around the Glas-Col’s inspection and a restocking charge of 15% of the original world. They will offer valuable assistance in your selections, delivery purchase price. Items superseded by current models cannot be and service after the sale. Please use our toll-free telephone number, returned for credit. Special, custom-designed items or catalog items 1-800-Glas-Col, if you need the name of a distributor in your area. modified for special voltage, wattage, dimensions, etc., will not be accepted for credit. New Accounts When restock is necessary due to a Glas-Col error in fulfilling an order, full credit will be given immediately upon receipt of the With approved credit, new direct accounts will be opened for order merchandise in question. amounts of $100 net or more. Orders for less than $100 may be prepaid, shipped COD, or paid by Visa, MasterCard, or American Purchaser should not deduct credit until merchandise is received, Express inspected, and a credit memo issued by Glas-Col. Terms Of Payment Inspection/Repair Service Upon approved credit, billing terms are Net 30 days. Otherwise, Glas-Col does not support or authorize any repairs outside of the arrangements may be made for Visa, MasterCard, American Express, factory. Products returned for repair not covered under warranty will advance payment, or COD. Invoices are payable in U.S.
    [Show full text]
  • Flinn Scientific 2019 Purchase Guide a Quick and Easy Checklist of Science Essentials
    Flinn Scientific 2019 Purchase Guide A Quick and Easy Checklist of Science Essentials Use this Purchase Guide as a handy tool for: • Taking Inventory • Order Preparation • Budget Management • Future Planning See your Flinn Scientific Catalog/Reference Manual SCIENTIFIC or visit www.flinnsci.com for product details. It’s Easy to Order Tom Trapp from Flinn Scientific! National Account Development Consultant [email protected] www.flinnsci.com/tom-trapp/sa1001 Online 402-960-5578 (mobile) www.flinnsci.com Offering personal assistance to help meet your science curriculum, supply, and lab safety needs. Email [email protected] Quality Products, Fast Delivery, Fax and Low Prices Guaranteed 1-866-452-1436 (toll free) Mail Flinn Scientific, Inc. P.O. Box 219 Batavia, IL 60510-0219 Phone 1-800-452-1261 7:30 am to 5:00 pm CT Monday through Friday Our Guarantee Flinn Scientific, Inc. guarantees that no sale is complete unless the customer is satisfied. Every item we furnish will either conform to the catalog specification, or we will ask your permission, prior to shipment, to ship an alternative product. If you find a lower published nationally advertised catalog price for an identical item, Flinn will “meet or beat” that price. Use this purchase guide containing popular product recommendations ©2019 Flinn Scientific, Inc. All Rights Reserved. to prepare your order, take inventory, and manage your budget. 1 www.flinnsci.com Flinn Scientific 2019 Purchase Guide 1 Item Rec. Item Rec. Product / Item Name Qty 2019 Price Total Product / Item Name Qty 2019 Price Total No. Qty No. Qty Safety & Personal Protection Equipment Aspirator, Water, Polypropylene AP1203 1 $ 19.30 $ - Apron, rubberized, 27" W X 36" L AP7125 30 $ 15.00 $ - Autoclave, Electric, Portable AP1004 1 $ 865.20 $ - Apron, plastic, 30" W x 36" L AP7120 30 $ 7.25 $ - ♦ Balance, Flinn Triple Beam OB2181 $ 115.00 $ - Gloves, Butyl rubber for conc.
    [Show full text]
  • Bunsen Burner Safety
    Proper Use of a Bunsen Burner If using a Bunsen burner in a biological safety cabinet, see: http://research.wayne.edu/oehs/pdf/gas-in-bsc.pdf Prior to Lighting Bunsen Burner: • Know the location of the laboratory’s main gas shut off valve and fire extinguisher. • Place the Bunsen burner away from any overhead shelving, equipment, or light fixtures by at least 12 inches. • Remove all papers, notebooks, combustible materials, and excess chemicals from the area. • Tie-back any long hair, dangling jewelry, or loose clothing. • Use correct tubing (butyl rubber hose). Inspect hose for cracks, holes, pinch points, or any defect and replace if necessary. Ensure that the hose fits securely on the gas valve and the burner. • Notify others in the lab that the burner will be in use. Lighting Bunsen Burner: • Before turning on gas, have a sparker/lighter with extended nozzle to ignite burner. Never use matches. • Check connections to burner and desk outlet valve. • Close needle valve and collar. • Open gas valve fully. • Open needle valve 1/2 turn. • Use the spark/lighter to light the flame. • Adjust flame by turning the collar to regulate air flow and produce an appropriate flame for the experiment (typically a medium blue flame). During Use: • Never leave a lighted burner unattended. Drafts (including those created by a hood) may extinguish the flame, but the gas will still be on. This could result in an explosion. • Never face the vessel (test tube, beaker, etc.) being used to heat a material toward yourself or others near the burner. In some experiments, a hot plate may be used in place of the Bunsen burner.
    [Show full text]
  • Heating Mantles
    HEATING MANTLES 17-1000: STIRMANTLE The StirMantle adds electromagnetic stirring capability (50-750 rpm) to the Series TM heating mantle for spherical flasks. Heating and stirring are independent; choose either or both. Speed is easily adjusted by a single dial on the StirControl II. The StirControl II creates and synchronizes the magnetic field. Its stirring speed is extremely stable, even at 50 rpm, despite temperature or load. When restarting (as for removal and reinsertion of the flask), Glas-Col's exclusive "Synchrostart" feature maintains linkage between the field and the bar. At restart, the selected speed is reached in approximately 4 seconds. The StirControl II connects to the StirMantle by cord, so it may be placed outside corrosive hood atmospheres and is easily accessible. Complete Complete StirMantle StirMantle Flask Outside Depth Height System System Only Only Capacity Watts Diameter (in) (in) 115V 230V 115V 230V (ml) (in) 100D 100D 100D 100D 250 180 1.64 6.25 4.75 EMS102 EMS103 TEM102 TEM103 100D 100D 100D 100D 300 180 1.70 6.25 4.75 EMS104 EMS105 TEM104 TEM105 100D 100D 100D 100D 500 270 2.00 6.25 5.25 EMS106 EMS107 TEM106 TEM107 100D 100D 100D 100D 1,000 380 2.56 7.50 5.50 EMS108 EMS109 TEM108 TEM109 100D 100D 100D 100D 2,000 500 3.35 10.00 6.50 EMS110 EMS111 TEM110 TEM111 100D 100D 100D 100D 3,000 500 3.60 10.00 6.50 EMS112 EMS113 TEM112 TEM113 Specifications Complete System: One StirMantle, one StirControl II, connecting cords, and stir bar. Completely grounded and fused.
    [Show full text]
  • SF#11086 Sterilization and Aseptic Technique
    Publication No. 11086 Sterilization and Aseptic Technique Introduction Microbiology lab activities are common in middle school and high school life science courses. Learning basic microbiology lab techniques and procedures is interesting and relevant to most students—many of them, after all, have had at least one throat culture or other microbiology lab test in their lives. The requirements for safe microbiological work in the classroom include the knowledge and practice of aseptic technique and sterilization procedures. Standard Microbiology Practices The federal government has outlined general safety standards for microbiological work in their publication Biosafety in Microbiological and Biomedical Laboratories. Biosafety Level I (BSL 1) practices described in this book are appropriate for secondary educational teaching laboratories. BSL 1 work involves using strains of viable, nonpathogenic microorganisms that are known not to cause disease in healthy adult humans and are thus of minimal potential hazard to students, teachers or the environ- ment. The level of containment in BSL 1 relies on standard microbiological practices in laboratory settings. Students and lab per- sonnel should receive specific training in the procedures conducted in the laboratory. Standard microbiological practices include: • Wash hands thoroughly with soap and water before and after handling viable materials, after performing microbiological transfers and observations or working with potentially hazardous materials, and before leaving the laboratory. • Eating, drinking, smoking, handling of contact lenses, applying cosmetics, and storing food for human use are not permit- ted in laboratory work areas. • Pipetting by mouth is prohibited—use only mechanical pipetting devices. • There should be policies and procedures for safe disposal of sharps, including broken glassware.
    [Show full text]
  • An Engineering Study of the Design, Integration and Control of Antibody Fragment Production Processes
    AN ENGINEERING STUDY OF THE DESIGN, INTEGRATION AND CONTROL OF ANTIBODY FRAGMENT PRODUCTION PROCESSES A thesis submitted to the University of London for the degree of Doctor of Philosophy by Leigh Caroline Bowering June 2000 Department o f Biochemical Engineering University College London Torrington Place London WC1E 7JE l To Mum and Dad 2 ACKNOWLEDGEMENTS I would like to thank Dr Nigel Titchener-Hooker and Professor Peter Dunnill for their supervision and support during this project. Special thanks must also go to Dr Neil Weir at Celltech Chiroscience Limited for his invaluable guidance and enthusiasm throughout the course of this research. Much of this work would not have been possible without the technical support of Billy Doyle, Ian Buchanan and Clive Osborne; their help has been greatly appreciated. I would like to extend my gratitude to the numerous researchers at University College London who have provided intellectual input and experimental support. In particular I would like to acknowledge Nick Murrell for his help with the large-scale fermentation and centrifugation experiments, Nik Willoughby for keeping me company during the numerous overnight fermentations and advising on expanded bed operation, and John Maybury for his input into the scale-down and modelling of the extraction and centrifugation processes. Special thanks must go to the many friends I made during my time in London, especially Natalie and Helen for keeping me smiling, my colleagues on the first floor for the constant supply of tea, coffee and cakes, and to Layth for providing the support and encouragement I needed for the successful completion of this thesis.
    [Show full text]
  • Drucker Diagnostics International Product Catalog
    Drucker Diagnostics International Product Catalog druckerdiagnostics.com +1-814-692-7661 © Copyright Drucker Diagnostics, 2017. All rights reserved. QBC and STAR are trademarks of Drucker Diagnostics. Form 1007 Rev. A Centrifuge Buying Guide STAT Centrifuges Innovative Solutions for a healthier world Digital Display Routine Centrifuges Since 1932, Drucker Diagnostics has led the way in quality, innovation, and reliability. Set & Lock Routine Centrifuges Whether it’s the first horizontal rotor or the world’s only dry hematology system, Drucker looks beyond the current standard and toward the ideal best practice. From our headquarters in Mobile Centrifuges Pennsylvania, we design, build, and support our product lines. You’ll find Drucker around the globe. Our centrifuges are trusted by reference laboratories, hospitals, point of care facilities, and Fixed-Angle Centrifuges more. Our dry hematology products can be found on cruise ships, in local clinics, on military bases, and wherever else remote care is required. Our sample protection lockboxes and SampleSafeTM Lockboxes fluorescence microscopy tools offer specimen protection and powerful diagnosis tools where they are needed most. Dry Hematology Fluorescence Microscopy Centrifuge Buying Guide Centrifuge Buying Guide Sodium Up to 17 Plasma Max Up to 17 Citrate PRP Mobile Max Digital x 75 or Model STAT Serum Urine G-Force Settings x 125 mm 50 mL Voltage (Coag) PRF Care RPM Display 100 mm (Chemistry) RCF or 15 mL PPP or 10 mL Cycle Time (Minutes) 642B* 10 15 3400 1600 One 6 115 VAC 642E
    [Show full text]
  • Modifications of Spectrophotometric Methods for Antioxidative Vitamins Determination Convenient in Analytic Practice *
    M PO RU LO IA N T O N R E U I M C S ACTA Acta Sci. Pol., Technol. Aliment. 6(3) 2007, 17-28 MODIFICATIONS OF SPECTROPHOTOMETRIC METHODS FOR ANTIOXIDATIVE VITAMINS DETERMINATION CONVENIENT IN ANALYTIC PRACTICE * Maciej Rutkowski, Krzysztof Grzegorczyk Medical University of Łód ź Abstract. Although there are numerous methods for quantitative determination of antioxida- tive vitamins: C, E, and A, there are no methods favourable for the broadly understood ana- lytic practice – they have various faults and limitations or require expensive apparatus. Therefore, we have elaborated modifications of valuable spectrophotometric methods for de- termination each of those vitamins, which originally could not be applied for laboratory practice from various regards. They are based on: for vitamin C – colour reaction with peri- odically prepared phosphotungstate reagent; for vitamin E – colour reaction with batophe- nanthroline, FeCl 3 and H 3PO 4; for vitamin A – spectrophotometric measurement of extracts of tested samples. Control tests showed complete correctness of analytic parameters ob- tained with those modifications with preservation of advantages of the original methods. Therefore they can be successfully implemented to the routine clinical analyses’. The elabo- rated modifications can also be used for determination of the a/m vitamins in foodstuffs, for example: in juices, milk and homogenates or extracts of solid food. Key words: antioxidative vitamins, spectrophotometry, food, biological samples INTRODUCTION In nutritional sciences and medicine, there is much interest in the analytics of vita- mins C, E and A because, besides having vitamin activity, they are also characterized by antioxidative action and are therefore defined as antioxidative vitamins.
    [Show full text]
  • Heating Mantles
    SELECTION GUIDE Heating Mantles OUR SELF-SUPPORTED CLOTH- SPILL-PROOF AND V-SHAPED ONE MANTLE—THREE SIZES! MULTI-POSITION HEATERS! JACKETED HEATING MANTLE! HEATING MANTLES! BASIC HEATING MANTLES Product Description Case Construction Built-In Controller Page HOTTEST SELLING COOL CASE HEATING MANTLES! Basic EM Series Polypropylene With/Without 100 TOP OF THE LINE METAL CASE MANTLES! Basic CM, CMU and UM Series Aluminum With/Without 104-106, 109 SO FLEXIBLE IT CAN BE USED FOR ROUND AND FLAT BOTTOM FLASKS! Basic MG Series Mesh No 110 COMPACT, ECONOMICAL CLOTH-JACKETED HEATING MANTLE! Basic HM Series Fiberglass No 111-112 MULTI-POSITION HEATERS! Basic EME and 5000 Series Aluminum With/Without 114-116 SPILL-PROOF HEATING MANTLES SPILL-PROOF AND V-SHAPED HEATING MANTLES! Basic Spill-proof EMX Series Polypropylene Yes 102 V-SHAPED HEATING MANTLES SPILL-PROOF AND V-SHAPED HEATING MANTLES! Basic EMV Series Polypropylene Yes 102 NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLE! Basic CMUV and CMV Series Aluminum With/Without 104-106 HEATING-STIRRING HEATING MANTLES HEAT AND STIR COOL CASE HEATING MANTLE! Heat-Stir EMA Series Polypropylene Yes 103 NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLES! Heat-Stir CMUA Series Aluminum No 104 OUR MODULAR HEATING MANTLE! Heat-Stir OM Series Aluminum Yes 108 MULTI-POSITION HEATERS! Heat-Stir EMEA Series Aluminum Yes 114 HIGH TEMPERATURE/RETORT BOTTOM HEATING MANTLES NEWEST-COOLEST INEXPENSIVE METAL CASE HEATING MANTLES! CMUH and CMUR Series Aluminum No 104 VARIABLE SIZED HEATING MANTLES TOP OF THE
    [Show full text]
  • T&S Quality Pet-Care Plumbing Products
    JA Pet-CarePre-Rinse Plumbing Units Products T&S Quality Pet-Care Plumbing Products – Our Pedigree is Your Quality Assurance RINSE UNITS Wash and Rinse Products Replacement Parts Model # Description EB-10K Repair Kit 013539-45 Replacement Hose PG-35AV Aluminum Valve PG-4DREV Lighweight Aluminum Spray Unit PG-35AV-CH Coiled Hose and Spray Valve • 4” (102 mm) deck-mount faucet (B-0326-LN) • Lightweight aluminum handle with rubber grip and hold down clip • ½” NPT female eccentric flanged inlets (00AA) • ¼” NPT male inlet • Vacuum breaker outlet • Coiled polyurethane hose with maximum stretching length of 9 ft. • 9 ft. coiled hose and aluminum spray valve • Lightweight spray valve for easy, all-day use PG-35AV-CH01 Same as PG-35AV-CH except with ¾” female garden • Wall hook hose inlet (PG-0001) PG-35AV-CH02 Same as PG-35AV-CH except with ³/8” NPT female PG-1DREV Same as PG-4DREV except single hole inlet (PG-0002) single temperature deck mount faucet with vacuum PG-35AV-CH03 Same as PG-35AV-CH except with ½” NPT female breaker inlet (PG-0003) PG-8DREV Same as PG-4DREV except with 8” centers PG-35AV-CH05 Same as PG-35AV-CH except with ¾” x 14 female inlet (052A) PG-8WSAV-08 Lighweight Aluminum Spray Unit PG-8WREV Lighweight Aluminum Spray Unit • 8” (203 mm) wall-mount faucet • 8” (203 mm) wall-mount faucet • ½” NPT female eccentric flanged inlets (00AA) • ½” NPT female eccentric flanged inlets (00AA) • Vacuum breaker • Vacuum breaker outlet • 9 ft. coiled hose and aluminum spray valve • 9 ft. coiled hose and aluminum spray valve • Swivel adapter • Lightweight spray valve for easy, all-day use • Add-on faucet with 8” swing nozzle and stream regulator outlet • Wall hook • Lightweight spray valve for easy, all-day use • Wall hook PG-1WSAV-06 Same as PG-8WSAV-08 except single hole wall-mount faucet with vacuum breaker, 9 ft.
    [Show full text]