Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography Mass Spectrometry

Total Page:16

File Type:pdf, Size:1020Kb

Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography Mass Spectrometry East Tennessee State University Digital Commons @ East Tennessee State University Electronic Theses and Dissertations Student Works 12-2011 Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography Mass Spectrometry. Archana Racharla East Tennessee State University Follow this and additional works at: https://dc.etsu.edu/etd Part of the Analytical Chemistry Commons Recommended Citation Racharla, Archana, "Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography Mass Spectrometry." (2011). Electronic Theses and Dissertations. Paper 1376. https://dc.etsu.edu/etd/1376 This Thesis - Open Access is brought to you for free and open access by the Student Works at Digital Commons @ East Tennessee State University. It has been accepted for inclusion in Electronic Theses and Dissertations by an authorized administrator of Digital Commons @ East Tennessee State University. For more information, please contact [email protected]. Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography – Mass Spectrometry ___________________________ A thesis presented to the faculty of the Department of the Chemistry East Tennessee State University In partial fulfillment of the requirements for the degree Master of Science in Chemistry __________________________ by Archana Racharla December 2011 _________________________ Dr. Chu-Ngi Ho, Chair Dr. Peng Sun Dr. Ningfeng Zhao Keywords: Onion, High Performance Liquid Chromatography, Gas Chromatography Mass Spectrometry, Flavonoid, Alliin. ABSTRACT Survey of Flavonoids and Their Distribution in Different Kinds of Onions Using High Performance Liquid Chromatography and Gas Chromatography – Mass Spectrometry by Archana Racharla This research is done to determine the distribution of flavonoids in diverse varieties of onions (commercial and wild onions). Reflux extraction method was done on dried onions and the abstracts were analyzed subsequently by high performance liquid chromatography (HPLC) and gas chromatography – mass spectrometry (GCMS). Statistical calculations were done to see if there are significant differences in the varieties of onions studied from the chromatographic profiles obtained. The chromatograms obtained were patterned using visual observations, scatter plot study, correlation co-efficient, and ANOVA to evaluate the significant difference of the distribution of flavonoids in varieties of onions. The organic white onions seem to have closer flavonoids profile to that of natural wild onions with a co- relation coefficient of 0.99 from HPLC data and 0.88 from the GCMS data. The ANOVA results also support these conclusions. However, natural wild onions tend to have more constituents that can be beneficial. 2 DEDICATION I would like to dedicate this work to everyone who encouraged me and gave me the strength to achieve my goals. I dedicate this thesis to Racharla (mom, dad, and brother) and Samala (husband and in-laws) families. I dedicate this thesis to all professors in Department of Chemistry at ETSU for their support and guidance to do better. 3 ACKNOWLEDGMENTS I would like to express my deepest and sincere gratitude to my supervisor Dr.Chu-Ngi Ho for his support, patience, guidance, and kindness throughout my studies. I am very thankful for having him as my advisor. I wish to express my sincere thanks to Dr. Peng Sun and Dr. Ningfeng Zhao for being on my thesis committee and their detailed and constructive comments have made this work a success. I esteemly thank Dr. Ray Mohseni and Mr. Mark Klein who supported me in learning the instrumental techniques throughout my study. My special regards to the faculty for their skills and knowledge that I have acquired throughout my course work, and the staff (Tom Webster and Walt Witt) of chemistry department at ETSU for their support in my graduate education. I would like to acknowledge department of chemistry and department of public health for awarding graduate assistantship. I indebtly thank my loving husband Dr. Mallikarjun Samala for his moral support, understanding and encouragement in every step of my education. I am grateful to my parents Mr. Shankaraiah and Ms. Madhulatha and my father-in-law Mr. Ashalu and my mother-in- law Ms. Amrutha and my sweet brother Avinash for their support and prayers. Finally, I would like to thank my friends, my fellow graduate students, and undergraduate students for their support. 4 CONTENTS Page ABSTRACT…………………………………………………………………………………...2 DEDICATION………………………………………………………………………………...3 ACKNOWLEDGEMENTS…………………………………………………………………...4 LIST OF TABLES…………………………………………………………………………….8 LIST OF FIGURES……………………………………………………………………………9 Chapter 1. INTRODUCTION…………………………………………………………………...10 Botany of Onion………………………………………………………………….10 Taxonomy of Onion…………………………...………………………………....11 The Chemical Composition and Chemistry of Allium Cepa.L……………….…12 Medicinal Properties and Uses of Onion…………………………..…………….16 2. METHODS OF FLAVONOID ANALYSIS………………………………………...18 Sample Preparation Techniques for Flavonoid Analysis………………………...18 Pressurized Liquid Extraction………………………………………………..18 Matrix Solid-Phase Dispersion……………………………………………….19 Supercritical Fluid Extraction………………………………………………..19 Microwave-Assisted Extraction……………………………………………...20 Solid Phase Extraction…………………………………………………….....20 Solid Phase Micro-Extraction………………………………………………..21 Ultrasonic Liquid Processor………………………………………………….21 5 Techniques for Separation and Identification of Flavonoids…………………….22 Chromatographic Techniques………………………………………………...22 Thin Layer Chromatography………………………………………....22 Gas Chromatography………………………………………………....23 High Performance Liquid Chromatography……………………….…25 Electrophoretic Techniques…………………………………………………..26 Capillary Electrophoresis…………………………………………….26 3. EXPERIMENTAL METHODS AND PROCEDURES…………………………..…28 High Performance Liquid Chromatography Process…………………………..…28 Isocratic Flow versus Gradient Elution…………………………………..…..29 Normal Verses Reversed Phase HPLC……………..………………………..30 HPLC Columns……….……………………………………………………...31 Detector Used in HPLC…………………………………………………..…..31 Use of Surfactants in HPLC…...………………………………………….….34 Gas Chromatography Process……………………………………………………36 Detector Used in GC…………………………………………...…………….36 Columns Used in GC………………………………………………………....39 Resolution of Bands……………………………………………………………...40 Method Development…………………………………………………………….41 Research………………………………………………………………………….42 4. EXPERIMENTAL PROCEDURES……………………………………………..…..43 Reagents…………………………………………………………………….…....43 Onion Samples...………………………………………………………………....43 Procedures………………………………………………………………..……....44 Preparation of Solutions……………………………………………………...44 6 Preparation of Onion Stock Samples…………………………………………44 Preparation of Standard Stock Samples……………………………………...46 HPLC Instrumentation……………………………………………………………….46 GCMS Instrumentation……………………………………………………………....48 Data Analysis………………………………………………………………………...49 5. RESULTS AND DISCUSSION…………….……………………………………….51 Optimization of Mobile Phase with Surfactants in HPLC…..…………..………...…51 Chromatograms of Onion Samples……………………...…………...………………52 Scatter Plot Study …………………………………………………………................59 Statistical Analysis…………………………………………………………………...64 6. CONCLUSIONS……………………………………………………………………..70 REFERENCES…………………………………………………………………….....73 VITA………………………………………………………………………………....78 7 LIST OF TABLES Table Page 1. Scientific classification of garden onion………………………………………….…12 2. HPLC parameters used for separation and analysis of flavonoids……………….….47 3. GCMS parameters used for separation and analysis of flavonoids………….……....48 4. Averaged retention times and their relative standard deviations from the HPLC chromatograms of the onion samples ……………..………………………………...62 5. Averaged retention times and their relative standard deviations from the GC-MS chromatograms of the onion samples …………….………………..………………...63 6. Correlation coefficients of the samples obtained from the HPLC chromatograms….65 7. Correlation coefficients of the samples obtained from the GCMS chromatograms…65 8. ANOVA p-values of the samples obtained from the HPLC chromatograms…..……68 9. ANOVA p-values of the samples obtained from the GC-MS chromatograms………68 8 LIST OF FIGURES Figure Page 1. Chemical structures of some sulfoxides from the Allium plants…………………....13 2. Enzymatic hydrolysis of Alliin to Allicin. Allicin further decomposes into sulfur compounds…………………………………………………………………………...14 3. Examples of flavonoids from Allium plants………………………………………....15 4. Examples of surfactants that are commonly used in determination of compounds….35 5. Schematic representation of High Performance Liquid Chromatography…………...47 6. Schematic representation of gas chromatographic instrumentation……………..…..49 7. HPLC chromatograms of myricetin, isorhamnetin, quercetin dydrate and quercetin 3- β-D glucoside………………………………………………………………………...52 8. HPLC chromatogram of commercial yellow onion sample……………...…………..53 9. HPLC chromatogram of commercial organic white onion sample……..………...…54 10. HPLC chromatogram of commercial organic red onion sample……………………..54 11. HPLC chromatogram of natural wild onion sample………...……………………….55 12. GCMS chromatogram of commercial yellow onion sample…………………………57 13. GCMS chromatogram of commercial white onion sample…………………………..57 14. GCMS chromatogram of commercial red onion sample……………………………..58 15. GCMS chromatogram of natural wild onion
Recommended publications
  • Gas Chromatography-Mass Spectroscopy
    Gas Chromatography-Mass Spectroscopy Introduction Gas chromatography-mass spectroscopy (GC-MS) is one of the so-called hyphenated analytical techniques. As the name implies, it is actually two techniques that are combined to form a single method of analyzing mixtures of chemicals. Gas chromatography separates the components of a mixture and mass spectroscopy characterizes each of the components individually. By combining the two techniques, an analytical chemist can both qualitatively and quantitatively evaluate a solution containing a number of chemicals. Gas Chromatography In general, chromatography is used to separate mixtures of chemicals into individual components. Once isolated, the components can be evaluated individually. In all chromatography, separation occurs when the sample mixture is introduced (injected) into a mobile phase. In liquid chromatography (LC), the mobile phase is a solvent. In gas chromatography (GC), the mobile phase is an inert gas such as helium. The mobile phase carries the sample mixture through what is referred to as a stationary phase. The stationary phase is usually a chemical that can selectively attract components in a sample mixture. The stationary phase is usually contained in a tube of some sort called a column. Columns can be glass or stainless steel of various dimensions. The mixture of compounds in the mobile phase interacts with the stationary phase. Each compound in the mixture interacts at a different rate. Those that interact the fastest will exit (elute from) the column first. Those that interact slowest will exit the column last. By changing characteristics of the mobile phase and the stationary phase, different mixtures of chemicals can be separated.
    [Show full text]
  • Coupling Gas Chromatography to Mass Spectrometry
    Coupling Gas Chromatography to Mass Spectrometry Introduction The suite of gas chromatographic detectors includes (roughly in order from most common to the least): the flame ionization detector (FID), thermal conductivity detector (TCD or hot wire detector), electron capture detector (ECD), photoionization detector (PID), flame photometric detector (FPD), thermionic detector, and a few more unusual or VERY expensive choices like the atomic emission detector (AED) and the ozone- or fluorine-induce chemiluminescence detectors. All of these except the AED produce an electrical signal that varies with the amount of analyte exiting the chromatographic column. The AED does that AND yields the emission spectrum of selected elements in the analytes as well. Another GC detector that is also very expensive but very powerful is a scaled down version of the mass spectrometer. When coupled to a GC the detection system itself is often referred to as the mass selective detector or more simply the mass detector. This powerful analytical technique belongs to the class of hyphenated analytical instrumentation (since each part had a different beginning and can exist independently) and is called gas chromatograhy/mass spectrometry (GC/MS). Placed at the end of a capillary column in a manner similar to the other GC detectors, the mass detector is more complicated than, for instance, the FID because of the mass spectrometer's complex requirements for the process of creation, separation, and detection of gas phase ions. A capillary column is required in the chromatograph because the entire MS process must be carried out at very low pressures (~10-5 torr) and in order to meet this requirement a vacuum is maintained via constant pumping using a vacuum pump.
    [Show full text]
  • Quality-Control Analytical Methods: Gas Chromatography
    QUALITY CONTROL Quality-Control Analytical Methods: Gas Chromatography Tom Kupiec, PhD Since GC is a gas-based separation technique, it is limited to Analytical Research Laboratories components that have sufficient volatility and thermal stability. Oklahoma City, Oklahoma Practical Aspects of Gas Chromatography Theory Introduction To understand GC and effectively use its practical applica- Chromatography is an analytical technique based on the tions, a grasp of some basic concepts of general chromato- separation of molecules due to differences in their structure graphic theory is necessary. Chromatographic principles, and/or composition. Chromatography involves moving a sam- including retention, resolution, sensitivity and other factors, ple through the system to be separated into its various compo- are important for all types of chromatographic separation, and nents over a stationary phase. The molecules in the sample will were discussed in volume 8, issue 3 (May/June 2004) of the have different interactions with the stationary support, leading International Journal of Pharmaceutical Compounding.1 to separation of similar molecules. Chromatographic separa- The GC section of United States Pharmacopeia (USP) 27 tions can be divided into several categories based on the Chapter <621> outlines the basic theory and separation tech- mobile and stationary phases used, including thin-layer chro- nique of GC. A compound is vaporized, introduced into the matography, gas chromatography (GC), paper chromatography carrier gas and then carried onto the column. The sample is and high-performance liquid chromatography (HPLC). then partitioned between the gas and the stationary phase. The GC is a physical separation technique in which components compounds in a sample are slowed down to varying degrees of a mixture are separated using a mobile phase of inert carrier due to the sorption and desorption on the stationary phase.
    [Show full text]
  • Experiment 4 Analysis by Gas Chromatography
    Experiment 4 Analysis by Gas Chromatography In this experiment we will study the method of gas chromatography. Gas chromatography (GC) is one of the most important analytical tools that the chemist has. In this lab you will watch and listen to a video presentation about GC, look at a research-level GC instrument, and learn how to do a qualitative and quantitative GC analysis. A schematic outline of a typical instrument is shown below. When a sample is injected into the correct column, a carrier gas sweeps the sample through the column. If necessary, an oven heats the system to vaporize the sample and speed its passage through the column. The different components of the sample will be separated by the column because each of the components “sticks” to the liquid coating that on the column packing differently. The greater the “stickiness,” the longer it takes for a substance to pass through the column. When a substance leaves the column, it is sensed by a detector. The detector generates a voltage that is proportional to the amount of the substance. The signal from the detector is then displayed by a chart recorder and/or fed into a computer. Modern gas chromatographs are connected to a computer which displays the peaks of all the substances in the sample. This is called the chromatogram. Software can perform all the calculations you will do in this experiment. An example of an analysis for cholesterol esters is shown above. If it could be done at all, this separation would take weeks by traditional wet chemistry.
    [Show full text]
  • The Determination of Water Utilizing Headspace Gas
    THE DETERMINATION OF WATER UTILIZING HEADSPACE GAS CHROMATOGRAPHY AND IONIC LIQUID STATIONARY PHASES by LILLIAN A. FRINK Presented to the Faculty of the Graduate School of The University of Texas at Arlington in Partial Fulfillment of the Requirements for the Degree of DOCTOR OF PHILOSOPHY THE UNIVERSITY OF TEXAS AT ARLINGTON August, 2016 Copyright © by Lillian A. Frink 2016 All Rights Reserved ii Acknowledgments This work would not have been possible without the help and support of many people. I would like to express my gratitude to my advisor, Professor Daniel W. Armstrong for his guidance, patience and support during my graduate studies. I consider myself fortunate to have the opportunity to pursue my Ph. D under his supervision. I would also like to thank my graduate committee members: Professor Kevin Schug and Professor Carl Lovely for their advice, guidance and times spent on my behalf during my graduate studies. I greatly appreciate the assistance of all faculty and staff in the Department of Chemistry and Biochemistry at the University of Texas at Arlington, especially Mrs. Barbara Smith. She has been helpful getting all the materials required for my research even when they were unconventional, and her friendliness and kind words were always appreciated. I would also like to thank Dr. Brian Edwards for his assistance in numerous ways. I would like to thank the support of Jeffrey Werner and Ryo Takechi at Shimadzu Scientific Instruments for their support and interest of my research. I appreciated Jeff for helping me to maintain the BID, introducing me to a pressure-loop headspace autosampler and teaching me about the electrons of a GC.
    [Show full text]
  • Separation Science - Chromatography Unit Thomas Wenzel Department of Chemistry Bates College, Lewiston ME 04240 [email protected]
    Separation Science - Chromatography Unit Thomas Wenzel Department of Chemistry Bates College, Lewiston ME 04240 [email protected] LIQUID-LIQUID EXTRACTION Before examining chromatographic separations, it is useful to consider the separation process in a liquid-liquid extraction. Certain features of this process closely parallel aspects of chromatographic separations. The basic procedure for performing a liquid-liquid extraction is to take two immiscible phases, one of which is usually water and the other of which is usually an organic solvent. The two phases are put into a device called a separatory funnel, and compounds in the system will distribute between the two phases. There are two terms used for describing this distribution, one of which is called the distribution coefficient (DC), the other of which is called the partition coefficient (DM). The distribution coefficient is the ratio of the concentration of solute in the organic phase over the concentration of solute in the aqueous phase (the V-terms are the volume of the phases). This is essentially an equilibration process whereby we start with the solute in the aqueous phase and allow it to distribute into the organic phase. soluteaq = soluteorg [solute]org molorg/Vorg molorg x Vaq DC = --------------- = ------------------ = ----------------- [solute]aq molaq/Vaq molaq x Vorg The distribution coefficient represents the equilibrium constant for this process. If our goal is to extract a solute from the aqueous phase into the organic phase, there is one potential problem with using the distribution coefficient as a measure of how well you have accomplished this goal. The problem relates to the relative volumes of the phases.
    [Show full text]
  • Gas Chromatography
    Gas Chromatography 1. Introduction 2. Stationary phases 3. Retention in Gas-Liquid Chromatography 4. Capillary gas-chromatography 5. Sample preparation and injection 6. Detectors (Chapter 2 and 3 in The essence of chromatography) Introduction A. General Information 1. First used in 1951, GC is currently one of the most popular method for separating and analyzing compounds. This is due to its high resolution, low limits of detection, high speed, high accuracy and high reproducibility. 2. GC can be applied to the separation of any compound that is either naturally volatile (i.e. readily goes into the gas phase) or can be converted to a volatile derivative. 3. GC is widely used in the separation of a number of organic and inorganic compounds, Examples of its applications are shown below: a. Petroleum product testing. b. Food testing and analysis c. Drug identification and analysis d. Environmental testing e. Characterization of natural and synthetic polymers B. Instrumentation: 1. The basic system consist of the following: A gas source (with pressure and flow regulators); an injector; a column (with an oven for temperature control); a detector; and a computer or recorder for data acquisition. 2. Advanced systems may contain an auto-injector, two or more columns and multiple detectors. 3. Extra-column band-Broadening a. Extra-column band-broadening refers to broadening of solute peaks that occurs at any place in the system other than the column. b. Band-broadening due to extra-column source is especially important for chromatographic system with small volumes or high efficiencies (small H). (e.g., Capillary GC column) c.
    [Show full text]
  • Marine Organic Geochemistry
    Marine Organic Geochemistry Analytical Methods – I. Extraction and separation methods. Reading list Selected Reading (Sample processing and lipid analysis) • Bidigare R.R. (1991) Analysis of chlorophylls and carotenoids. In Marine Particles: Analysis and Characterization. Geophysical Monograph 63. 119-123. • Wakeham S.G. and Volkman J.K. (1991) Sampling and analysis of lipids in marine particulate matter. In Marine Particles: Analysis and Characterization. Geophysical Monograph 63. 171-179. • Nordback J., Lundberg E. and Christie W.W. (1998) Separation of lipid classes from marine particulate matter by HPLC on a polyvinyl alcohol-bonded stationary phase using dual-channel evaporative light scattering detection. Mar. Chem. 60, 165-175. Background Reading • Jennings W. (1978) Gas Chromatography with Glass Capillary Columns. Academic press • Snyder L.R., Kirkland J.J., Glajch J.L. (1997) Practical HPLC method development. 2nd Edition. Wiley. • Christie W.W. (1982) Lipid Analysis. 2nd Edition. Pergamon. • Ikan R. and Cramer B. (1987) Organic chemistry: Compound detection. Encyclopedia of Physical Science and Technology 10, 43-69 Practical considerations regarding sample storage, preparation, and safety (an organic geochemical perspective) Sample storage • Many organic compounds are biologically or chemically labile. • Susceptibility to: Enzymatic hydrolysis (e.g., DNA, Phospholipid Fatty Acids - PLFA) Photolysis (e.g., certain PAH - anthracene). Oxidation (e.g. polyunsaturated lipids) • Ideally, samples should be kept frozen, in the dark and under N2. < -80°C : minimal enzymatic activity - optimal. < -30°C: a good compromise. 4°C (refridgeration): OK for short periods of time room temp – ok once sample has been dried (for many compounds). *total lipid extracts are more stable than purified compounds/fractions Sample preparation • Drying of samples will deactivate enzymes, but can lead to oxidation of selected compounds.
    [Show full text]
  • Biochemistry 12 Gas Liquid Chromatography
    Biochemical Techniques Biochemistry 12 Gas Liquid Chromatography Description of Module Subject Name Biochemistry Paper Name 12 Biochemical Techniques Module Name/Title 12 Gas - liquid Chromatography Biochemical Techniques Biochemistry 12 Gas Liquid Chromatography 1. Objectives 1.1 To understand principle of Gas Liquid Chromatography 1.2 To explain the different components of GLC 2.0 Introduction and principle- Introduction and principle- Gas – Liquid chromatography (GLC) is one of the most useful techniques in analytical chemistry. Claesson published one of the first important accounts of gas liquid chromatography in 1946. Gas – liquid chromatography is a form of partition chromatography in which the stationary phase is a film coated on a solid support and the mobile phase is an inert gas like Nitrogen (N2) called as carrier gas flowing over the surface of a liquid film in a controlled fashion. The sample under analysis is vaporized under conditions of high temperature programming. The components of the vaporized sample are fractionated as a result of partitioning between a mobile gaseous phase and a liquid stationary phase held in a column. Principle: When the vapours of sample mixture move between the stationary phase (liquid) and mobile phase (gas) the different components of a sample mixture will separate according to their partition coefficient between the gas and liquid stationary phase. Concn. of solute in liquid (w/cc) Partition coeff.(Kg) = -------------------------------------------- Concn of solute in gas (w/cc) It is general assumption that if partition coefficient is low the emergence of the component is fast and vice versa. The substances having low boiling point (B.P) i.e.
    [Show full text]
  • Gas-Chromatography/Mass Spectrometry (GC-MS) Interpretation of EI Spectra
    Gas-chromatography/mass spectrometry (GC-MS) Interpretation of EI spectra Jeremy Keirsey CCIC MSP Mass Spec Summer Workshop August 17, 2015 Gas Chromatography Important goals in chromatography - Achieve the best separation - Little band-broadening – narrow chromatogram peaks – efficient column - “Dynamic range” - Separate and detect the “small” in the close vicinity of the “big” - Reproducibility - Stable peak positions, retention times Even with the best column diffusion always plays a role! Parameters to control diffusion Particle size (Column type) Flow rate The Van Deemter Equation HETP = A + (B/u) + (Cs + Cm) × u HETP = height equivalent to a theoretical plate -a measure of the resolving power of the column H = L/N The Van Deemter Equation HETP = A + (B/u) + (Cs + Cm) × u •HETP = height equivalent to a theoretical plate, a measure of the resolving power of the column [m] (Height = Length/number of plates=L/N) •A = Eddy-diffusion parameter, related to channeling through a non-ideal packing [m] •B = diffusion coefficient of the eluting particles in the longitudinal direction, resulting in dispersion [m2 s−1] •C = Resistance to mass transfer coefficient of the analyte between mobile [m] and stationary phase [s] •u = Linear Velocity [m s−1] Original paper: Van Deemter JJ, Zuiderweg FJ and Klinkenberg A (1956). "Longitudinal diffusion and resistance to mass transfer as causes of non ideality in chromatography". Chem. Eng. Sc. 5: 271–289 Youtube: https://www.youtube.com/watch?v=8i_4-OMCANE The Van Deemter Curve Resolution Solute moving through a column spreads into a Gaussian shape with standard deviation σ. Common Measures of breadth are: 1) The width w½ measured at half-height 2) The width w at the baseline between tangents drawn to the steepest parts of the peak (inflection points).
    [Show full text]
  • Early Stages in the History of Gas Chromatography
    Accepted Manuscript Title: Early Stages in the History of Gas Chromatography Authors: Ivan G. Kolomnikov, Alexander M. Efremov, Tatyana I. Tikhomirova, Nadezhda M. Sorokina, Yury A. Zolotov PII: S0021-9673(18)30006-2 DOI: https://doi.org/10.1016/j.chroma.2018.01.006 Reference: CHROMA 359132 To appear in: Journal of Chromatography A Received date: 10-10-2017 Revised date: 28-12-2017 Accepted date: 2-1-2018 Please cite this article as: Ivan G.Kolomnikov, Alexander M.Efremov, Tatyana I.Tikhomirova, Nadezhda M.Sorokina, Yury A.Zolotov, Early Stages in the History of Gas Chromatography, Journal of Chromatography A https://doi.org/10.1016/j.chroma.2018.01.006 This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. Early Stages in the History of Gas Chromatography Ivan G. Kolomnikova, Alexander M. Efremova, Tatyana I. Tikhomirovaa, Nadezhda M. Sorokinaa, Yury A. Zolotova, b, * aDepartment of Chemistry, Lomonosov Moscow State University, Leninskie Gory, 1/3, GSP-1, Moscow 119991, Russia b Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Moscow, 119991 Russia *Corresponding author. Tel.: +7(495)939-55-64 E-mail: * [email protected] ACCEPTED MANUSCRIPT 1 Highlights The history of gas chromatography began earlier than famous Archer Martin’s works Most of the earlier chromatographic studies dealt with gas-adsorption chromatography Early studies were carried out mostly in Germany, Austria, UK and USSR Abstract The creation of gas chromatography is traditionally associated with the names of Nobel Prize winner Archer Martin and his colleagues Richard Synge and Anthony James.
    [Show full text]
  • Gas and Liquid Chromatography - Sliepcevich A
    FUNDAMENTALS OF CHEMISTRY – Vol. I - Gas and Liquid Chromatography - Sliepcevich A. and Gelosa D. GAS AND LIQUID CHROMATOGRAPHY Sliepcevich A. and Gelosa D. Politecnico di Milano, Italy Keywords: adsorption, affinity, analysis, capacity, capillary, carrier, chromatography, column, degaser, detector, distribution, ECD, efficiency, elution, exclusion, FID, GC, HETP, HPLC, HWD, injection, injector, ion exchange, ionization, LC, mass spectrometer, megabore, mobile phase, normalization, on-column, packed, packing, partition, photomultiplier, polarity, pump, retention time, separation, signal, split, splitless, standard, stationary phase, thermal conductivity detector (TCD), technique, TLC Contents 1. Introduction 2. Evolution and Classification of Chromatography 2.1. Adsorption Chromatography 2.2. Partition Chromatography 2.3. Ion-Exchange and Size-Exclusion Chromatography 2.4. Affinity Chromatography 3. Chromatographic Theory 3.1. Distribution of Analytes Between Phases 3.2. Separation Efficiency 4. Gas Chromatography 4.1. Sample Introduction 4.1.1. Packed-Column Injector 4.1.2. Inlet for Capillary Column 4.2. Column 4.3. Detectors 4.3.1. Hot-Wire Detector 4.3.2. Flame-Ionization Detector 4.3.3. Electron-Capture Detector 4.3.4. Mass-Spectrometer Detector 5. High PerformanceUNESCO Liquid Chromatography – EOLSS 5.1. Instrumentation for HPLC 5.1.1. Mobile-Phase Reservoir 5.1.2. Pumps 5.1.3. Injectors SAMPLE CHAPTERS 5.1.4. Columns 5.1.5. Detectors 6. Analytical Objectives 6.1. Qualitative Analysis 6.2. Quantitative Analysis 6.2.1. Uncalibrated Calculation Procedures 6.2.2. Calibrated Calculation Procedures Glossary Bibliography ©Encyclopedia of Life Support Systems (EOLSS) FUNDAMENTALS OF CHEMISTRY – Vol. I - Gas and Liquid Chromatography - Sliepcevich A. and Gelosa D. Biographical Sketches Summary Chromatography is the most important technique of separation of chemical substances, and is based on the physical interaction of a solute with two different phases.
    [Show full text]