SIC-A Communication Solutions

Redundancy Protocols Gateway (PRP/HSR) • Communication Solutions for Smart Grid. • Supported protocols: IEC 61850, IEC 60870-5-101/103/104, DNP3 serial/TCP, RTU/ASCII/TCP, IEC 62056 - DLMS, IEC 61400, ... • Multifunction:

Redbox SIC-A Working as a Redbox allows the connection of HSR networks with traditional ones. In case of PRP redundancy, SIC-A is not denominated Redbox, it would be a device that allows the integration into 2 independent networks through a 3rd port.

Protocol Gateway SIC-A device is able of communicating through serial communication RS-232 or RS-485 with multiple equipment with a Master serial protocol (Modbus, IEC69870-5-101, IEC60870-5-103, DLMS…) and dispose the information into a Ethernet protocol as IEC 61850 or IEC 60870-5-104. This way, devices with conventional protocols can be integrated in Ethernet networks with advanced protocols.

Redundant Protocol Gateway It is the result of the combination of the functionality of a Gateway and the HSR redundancy. With this configuration, SIC-A allows the integration of equipment with serial communications in a HSR redundant network with an advanced protocol as IEC 61850 or IEC 60870-5-104

Most complete topology 2 SIC-A in their topology of Redbox allow connecting a HSR redundant network with another PRP network. This is a useful application that permits to coexist new networks with existing ones. In the same way, SIC-A in its topology of PRP Gateway, would allow to integrate serial equipment with conventional protocols in a PRP network with an advanced Ethernet protocol as IEC61850, IEC 60870-5-104, etc.

ApplicationApplication diagram diagram

  PRP IEDS

MODBUS RTU (RS232)

MODBUS RTU (RS485) PRP Gateway

RedBox A LAN A LAN B RedBox B

HSR IEDS  Dimensions and cutout pattern Technical parameters

IEC 60870-5-101/103/104, DNP3 serial TCP/IP, UDP/IP, SMTP, POP, HTTP, System /TCP, Modbus RTU/ASCII/TCP, FTP, SNMP, ICMP, DHCP, BOOTP, Protocols Standard Protocols IEC62056-DLMS, IEC61850, IEC61400, Telnet, DNS,ARP, PPPoE, DDNS ODBC, IEEE37.118 800 (IEC61850), 3000 (DNP3, IEC 60870, Communication Supported Data Points Modbus, etc.) Capability Device Security NERC/CIP compliant, SSHv2 Serial: 1 RS232 –DB9 and 1 RS485 terminal connector. Interfaces Ethernet: 3 x 10/100 Mbps RJ45 connector and Optional 3 x SFP 100Base-FX 1300nm IEC62351-3 and -5 (DNP3 secure Communication with LC fiber connector authentication), SSL based VPN tunnel General Security using Blowfish/AES/3DES Power Auxiliary Power 48-110 Vdc / 48-230 Vac ±20% Requirements Consumption 6W max. AND/OR/NOT/Bit SHIFT/Split/Index Logic Dimensions (H x W x D) 164 x 64,2 x 136mm support for digital and analog data Programming delay operations Weight 1 Kgr. Physical LED Indications Power, Gateway, HSR/PRP Compliant implementation of both PRP (IEC62439-3-4) and HSR (IEC62439- Mounting DIN Rail and wall mounting Redundancy Operating Temperature -40ºC to + 85ºC hardware solution with low switching Environmental latency IP 20

Dimensions Selection & Ordering data

SIC-A PROTOCOL GATEWAY / REDBOX Advance protocol gateway with Redundancy

FUNCTION 1 Redbox 164 2 Protocol Gateway

35.7 3 Redundant Protocol Gateway 64.2 POWER SUPPLY C 48-110 Vdc / 48-230 Vac

ETHERNET PORT 194 0 RJ-45 1 RJ-45 + SFP LC Connector

REDUNDANCY PORTS 0 RJ-45 12.2 1 RJ-45 + SFP LC Connector

REDUNDANCY TYPE 0 None HSR

136 1 2 PRP

MASTER/CLIENT PROTOCOL A None B MODBUS RTU 194 C IEC 60870-5-103 D DNP3.0 (serial) E IEC 60870-5-101 136 F DLMS/COSEM

SLAVE/SERVER PROTOCOL 65.2 A None B IEC 61850 C DNP3.0 TCP/IP 12.2 136 D IEC 60870-5-104 E MODBUS TCP/IP

ADAPTATION A -

04/2015/D01

Fanox reserves the right to modify technical specification of www.fanox.com [email protected] Tlf. +34 94 471 14 09 Fax +34 94 471 05 92 products contained within this documentation without previous notice.