Quick Reference | Gypsum Cement Underlayment 03 54 13

Total Page:16

File Type:pdf, Size:1020Kb

Quick Reference | Gypsum Cement Underlayment 03 54 13 QUICK REFERENCE | GYPSUM CEMENT UNDERLAYMENT 03 54 13 1. Product Name of over two billion square feet GYP-SPAN® Radiant installed nationwide, HFU Designed for use with radiant heat Hacker Floor Underlayments are appropriate for use over systems, enhanced thermal mass ® FIRM-FILL Gypsum Concrete concrete, wood, steel deck or and heat transfer. 2000-3200 psi ® FIRM-FILL 2010+ radiant substrates. With proper (13.8-22.1 MPa). FIRM-FILL® 3310+ preparation, virtually any type FIRM-FILL® High Strength of fnished foor covering can be Hacker Sound Mat II FIRM-FILL® 4010+ installed over HFU. All HFU meet Sound control mat; composed of FIRM-FILL® CMD ASTM F2419. (See Technical Data). recycled rubber; increases STC and GYP-SPAN® Radiant IIC ratings. Hacker Sound Mat II COMPOSITION & MATERIALS FIRM-FILL® SCM FIRM-FILL® Gypsum Concretes and • FIRM-FILL® SCM Hacker Floor Primer GYP-SPAN® Radiant are mixed with A range of dimensional acoustical Hacker Floor Sealer washed plaster or masonry sand, control mats. Hacker TopCoat™ SP per ASTM C33, and potable water to form HFU. APPLICATION THICKNESS *Note: For cementitious Minimum application thickness of applications, consult TRUE-SCREED® CLU Spec Data Sheet. TYPES HFU is: FIRM-FILL® Gypsum Concrete 2. Supplier Designed for use in multi-family • Over wood: 3/4” (19 mm) of housing to attain sound and fre HFU Hacker Industries, Inc. ratings. 1200 2000 psi (8.3-13.8 • Over concrete slabs: HFU may 1600 Newport Center Drive, Suite MPa). be featheredged in transition 275 areas Newport Beach, CA 92660 USA • FIRM-FILL® 2010+ • Over radiant heat tubes: Phone (949) 729-3101 Additional surface hardness and Minimum 3/4” (19 mm) on top (800) 642-3455 higher compressive strength. of radiant tubes Fax (949) 729-3108 2000-3200 psi (13.8-22.0 MPa). • Over Sound Control Mats: See www.HackerIndustries.com supplier recommendations for e-mail: [email protected] • FIRM-FILL® 3310+ thickness An exceptionally smooth, rock- • Maximum thickness: 3. Product Description solid, surface over wood subfoors. 3-1/2” (89 mm) 3000- 3900 psi (20.6-26.8 MPa). BASIC USE • Over corrugated steel deck: 1” (25 mm) over top of futes Hacker Floor Underlayments FIRM-FILL® High Strength (HFU) are lightweight, high- For resurfacing damaged, uneven LIMITATIONS strength, durable, nonstructural or cracked concrete foors and • Do not use HFU in exterior cementitious underlayments for planks. 2500-3800 psi (17.2-26.2 locations. use in multi-family, residential, MPa). • HFU require a fnished foor commercial and radiant heating covering. ® projects for both new construction • FIRM-FILL 4010+ • Gypsum based systems shall and renovation. Trained Licensed Ofers superior bonding not be used below grade or Applicators can install up to 40,000 capabilities for thin capping of where prolonged exposure to 2 2 ft (3716 m ) per day. The fnished concrete foors. 4000-5200 psi moisture is likely. products provide a superior crack- (27.5- 34.4 MPa). • Subfoor must support design resistant surface that is integral to loads with maximum L/360 a fre and sound rated system. FIRM-FILL® CMD For cold-formed steel frame defection. Since 1983, Hacker Industries, construction with a corrugated • HFU above crawl spaces Inc. has provided the most cost- steel deck. Min. 3500 psi (24.1 must be protected by a vapor efective and high strength MPa). barrier. underlayments in the industry. • Do not apply less than 1-1/2” With the proven performance (38 mm) of HFU on plastic vapor barrier. SPEC-DATA® and MANU-SPEC® are registered trademarks of Reed Elsvier, Inc. FIRM-FILL® GYP-SPAN®, TRUE-SCREED® and the associated logos are registered trademarks of Hacker Industries, Inc., Newport Beach, CA. © 2017 Hacker Industries, Inc. Product Contributes towards LEED® credits. Hacker Industries, Inc. | Architect Binder | Spec Data | © 2017 143 03 54 13 Gypsum Cement Underlayment QUICK REFERENCE | GYPSUM CEMENT UNDERLAYMENT 03 54 13 Hacker Industries, Inc. L544, L545, L546, L547, L548, L549, L550, as stated by Hacker Industries, Inc.’s • HFU are one component of an (38 mm) thickness weighs 14.6 FLOOR COVERING 3/4” (19 MM) HACKER efective sound and fre control psf (71.3 kg/m2) FLOOR UNDERLAYNMENT L551, L552, L553, L555, L556, L557, L558, current literature. L559, L570, L574, L560, L562, L563, L571, system. 5/8” (16 MM) PLYWOOD DENSITY L585, L590, L592, L593, L598, M502, Dryness Test: Prior to the installation of 2” x 10” (51 MM x 254 MM) M506, M508, M512, M513. finished floor goods, Hacker Industries, 3 Care must be taken in the 107-130 pcf (1682-2082 kg/m ) WOOD JOIST Inc. recommends that a moisture test installation of all components minimum dry density RESILIENT CHANNEL Canada: L003, L201, L511, L512, M500, be done. Consult floor covering to ensure the ultimate design M501, M503, M505, M506, M507, M508, manufacturer for recommended 1/2” (13 MM) TYPE X OR 5/8” M509, M514, M518, M520. procedures to test for dryness and performance. Published acoustical FIRE PERFORMANCE (16 MM) GYPSUM WALLBOARD OPTIONAL: SOUND CONTROL MAT acceptable moisture levels. Calcium and fre system tests were HFU are included in over 100 UL FIRE HAZARD CLASSIFICATION chloride is not an approved method. To conducted under controlled listings: Figure 1: Wood System ASTM E84: Flamespread Index, 0; Fuel avoid potential problems during the laboratory or feld conditions and Contribution, 0; Smoke Density, 0. drying process, the General Contractor refect results applicable only to G561, G565, G568, J917, J919, J920, shall consult Hacker Industries, Inc.’s J924, J927, J931, J957, J966, J991, FLOOR COVERING MIN. 1” (25 MM) FIRM-FILL® CMD ACOUSTICAL PERFORMANCE Drying Conditions Flyer and informa- those specifc assemblies. OVER TOP OF FLUTES HFU contribute to superior STC (Sound tion contained on Hacker Industries, J994, K906, L001, L004, L005, L006, Transmission Class) and IIC (Impact Inc.’s website for additional information CORRUGATED STEEL DECK 4. Technical Data L201, L202, L206, L208, L209, L210, Insulation Class) ratings. Additional sound concerning drying of this product. L211, L212, L501, L502, L503, L504, 14” 14 GAUGE STEEL JOIST reduction is achieved using a sound control APPLICABLE STANDARDS L505, L506, L507, L508, L509, L510, mat with HFU. PROTECTION • ASTM F2419 Standard Practice RESILIENT CHANNEL During construction, General Contractor L511, L512, L513, L514, L515, L516, 5. Installation shall place temporary wood planking in for Installation of Thick L517, L518, L519, L520, L521, L522, BATT INSULATION GYPSUM WALLBOARD SITE CONDITIONS areas subject to wheeled or concentrated OPTIONAL: SOUND CONTROL MAT Poured Gypsum Concrete L523, L524, L525, L526, L527, L528, HFU shall be delivered in original, loads. Underlayments and the L529, L530, L531, L532, L533, L534, Figure 2: Corrugated Steel Deck unopened bags, stored away from exposure Preparation of the Surface to to elements, and above 50˚F (10˚C). Do not BUILDING CODES L535, L536, L537, L538, L539, L540, allow bags to get wet. Do not use beyond Installation of HFU must comply with Receive Resilient Flooring L541, L542, L543, L544, L545, L546, shelf life. applicable local, state, and national code FLOOR COVERING GYP-SPAN® RADIANT (THICKNESS • ASTM C472 Modifed Standard L547, L548, L549, L550, L551, L552, DEPENDENT ON DIAMETER OF requirements. TUBES Test Methods for Physical L553, L555, L556, L557, L558, L559, Building temperature shall be maintained TUBES OR CABLES above 50˚F (10˚C) before, during, and after 6. Availability & Cost Testing of Gypsum, Gypsum L570, L574, L560, L562, L563, L571, 5/8” (16 MM) PLYWOOD installation until the subfloor, ambient HFU are only installed by Licensed Plasters and Gypsum Concrete L585, L590, L592, L593, L598, M502, OR CONCRETE temperature, and humidity have stabilized Applicators. Contact Hacker Industries, Inc. • ASTM E84 Standard Test M506, M508, M512, M513. WOOD JOIST OR and material has completely dried. for the applicator(s) in your area. Method for Surface Burning TRUSS SYSTEM 1/2” (13 MM) TYPE X OR 5/8” PREPARATION 7. Warranty Characteristics of Building Canada: L003, L201, L511, L512, M500, (16 MM) GYPSUM WALLBOARD M501, M503, M505, M506, M507, General Contractor shall confirm the HACKER INDUSTRIES, INC. WARRANTS Materials Figure 3: Radiant Heat System subfloor is structurally sound and conditions HFU TO BE FREE FROM MANUFACTUR- • 2012 Tile Council of North M508, M509, M514, M518, M520. are suitable for installation of floor underlay- ING DEFECTS, AND WHEN PROPERLY America Handbook - ment. Subfloor must be dry, broom cleaned, PREPARED AND INSTALLED ACCORD- APPROVALS and completely free of oil, grease, paraffin, ING TO APPROVED SPECIFIED METH- Installation Methods F180, FLOOR COVERING STUD • ICC-ES Legacy Report ER-4147 wax, laitance and other contaminants. ODS, HFU WILL ATTAIN MINIMUM F200, RH111, and RH122. Subfloor shall be tested for moisture before PHYSICAL SPECIFICATIONS AS STATED • City of Los Angeles RR No. 1/2” (13 MM) OR 3/4” (19 MM) HACKER FLOOR UNDERLAYMENT the installation of HFU. BY HACKER INDUSTRIES, INC.’S MOST WEIGHT 24540 RECENT LITERATURE. HACKER PRECAST CONCRETE • FIRM-FILL® Gypsum Concrete – • U.S. Department of Housing APPLICATION INDUSTRIES, INC.’S OBLIGATION SHALL 3/4” (19 mm) thickness weighs and Urban Development FHA- Prior to installation of HFU, the building BE LIMITED TO THE REPLACEMENT OF 2 must be enclosed, including roof, windows, THE BAGGED PRODUCT ONLY AND IS 7 psf (34.2 kg/m ) HUD-1255 and doors. Install HFU after radiant heat SUBJECT TO NOTICE AND INSPECTION • FIRM-FILL® 2010+ – 3/4” (19 OPTIONAL: SOUND CONTROL MAT tubing has been put in place. Provide REQUIREMENTS. FIRE HAZARD CLASSIFICATION constant ventilation to remove moisture mm) thickness weighs 7.2 psf Figure 4: Concrete System (35.2 kg/m2) ASTM E84: Flamespread Index, from the area until the underlayment is THIS WARRANTY IS IN LIEU OF ALL ® 0; Fuel Contribution, 0; Smoke completely dry. If necessary, the General OTHER WARRANTIES, EXPRESS OR • FIRM-FILL 3310+ – 3/4” (19 Contractor shall provide mechanical heat.
Recommended publications
  • New Fayette County Prison Volume 2 Divisions 03
    SECTION 03 1000 CONCRETE FORMING AND ACCESSORIES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract, including General and Supplementary Conditions and other Division 01 specification sections, apply to requirements of this Section. 1.02 SECTION INCLUDES A. Formwork for cast-in place concrete, with shoring, bracing and anchorage. B. Openings for other work. C. Form accessories. D. Form stripping. 1.03 RELATED REQUIREMENTS A. Section 03 2000 - Concrete Reinforcing. B. Section 03 3000 - Cast-in-Place Concrete. C. Section 04 2001 - Masonry Veneer: Spacing for veneer anchor reglets recessed in concrete. 1.04 REFERENCE STANDARDS A. ACI 117 - Specifications for Tolerances for Concrete Construction and Materials. B. ACI 301 - Specifications for Structural Concrete. C. ACI 318 - Building Code Requirements for Structural Concrete and Commentary. D. ACI 347R - Guide to Formwork for Concrete. E. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes. F. ASTM B221M - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric). G. PS 1 - Structural Plywood. 1.05 SUBMITTALS A. Shop Drawings: Indicate pertinent dimensions, materials, bracing, and arrangement of joints and ties. B. Designer's Qualification Statement. C. Design Data: As required by authorities having jurisdiction. 1.06 QUALITY ASSURANCE A. Designer Qualifications: Design formwork under direct supervision of a Professional Structural Engineer experienced in design of concrete formwork and licensed in the State in which the Project is located. 1.07 DELIVERY, STORAGE, AND HANDLING A. Deliver prefabricated forms and installation instructions in manufacturer's packaging.
    [Show full text]
  • USG Levelrock® 2500 Floor Underlayment Architectural Spec
    SECTION 03540 [03 54 13] ® Cementitious Underlayment LEVELROCK ™ 2500 Specification PART 1 - GENERAL ***Notes to Architect are highlighted in red**** 1.01 SUMMARY A. Description of Work: Work of this sections includes self leveling underlayment for interior finish flooring but is not limited to, the following: ® 1. LEVELROCK 2500™ Floor Underlayment covering normal project conditions and applications. 2. Division 3 Section “Concrete Toppings” applied over various substrates. 3. Division 9 Section sound control, patching, and leveling compounds applied with finish flooring. 1.02 REFERENCES A. ASTM C472 Compressive Strength B. ASTM C33 Sand Aggregate C. ASTM D4263 Standard test method for indicating moisture in concrete D. ASTM F2419 Standard test method for installation of thick poured Gypsum concrete and preparation of surface to receive resilient flooring E. ASTM E492 Impact Insulation Class (IIC) F. ASTM E90 Sound Transmission Class (STC) 1.03 RELATED WORK SPECIFIED ELSEWHERE A. See Section 9 for acceptable flooring materials including vinyl, tile, wood, and laminates. 1.04 SUBMITTALS A. Product Data: Submit manufacturer’s specifications and installation instructions with project conditions and materials clearly identified or detailed for each required product or system. B. Acoustical Data: Submit sound tests according to IBC code criteria ASTM E492 (IIC) and ASTM E90 (STC) 1. Submit in writing that all sound tests or data provided has been tested according to UL (Underwriters Laboratory) fire resistance design number. ® ™ Cementitious 03540 - 1 LEVELROCK 2500 Underlayment Floor Underlayment Updated 9/6/06 1.05 SYSTEM REQUIREMNETS A. Performance Requirements: ® 1. LEVELROCK 2500™ Floor Underlayment a. Minimum compressive strength 2,500 psi.
    [Show full text]
  • IJCIET), ISSN 0976 –AND 6308 (Print), ISSN 0976 – 6316(Online)TECHNOLOGY Volume 4, Issue (IJCIET) 3, May - June (2013), © IAEME
    INTERNATIONALInternational Journal of Civil JOURNAL Engineering OFand TechCIVILnology ENGINEERING (IJCIET), ISSN 0976 AND– 6308 (Print), ISSN 0976 – 6316(Online)TECHNOLOGY Volume 4, Issue (IJCIET) 3, May - June (2013), © IAEME ISSN 0976 – 6308 (Print) ISSN 0976 – 6316(Online) IJCIET Volume 4, Issue 3, May - June (2013), pp. 168-175 © IAEME: www.iaeme.com/ijciet.asp Journal Impact Factor (2013): 5.3277 (Calculated by GISI) © IAEME www.jifactor.com THE EFFECT OF GYPSUM COMPENSATIVE ON MORTAR COMPRESSIVE STRENGTH Alaa Abdul Kareem Ahmad Advanced Chief Engineer, College of Engineering, University of Al-Anbar,Al-Ramadi, Iraq. ABSTRACT The gypsum concrete is a new type of concrete and has its usage. This study aimed to know the effect of the gypsum on the compressive strength using 2 inch. or 50 mm cube specimen. They compensated 5%, 15% and 25% of the cement by the gypsum respectively for making six specimens for each treatment of the gypsum had been studied. Comparing their compressive strength at age (3) days and at age (7) days with a control mortar mix at the same ages. The results shown that the compressive strength for cement mortar is decrease whenever the compensated 5%, 15% and 25% of the cement by the gypsum 38.8%, 60.5% and 68.5% respectively for (3) days age specimens. The compressive strength for cement mortar is decrease whenever the compensated 5%, 15% and 25% of the cement by the gypsum 38.1%, 58.4% and 66.1% respectively for (7) days age specimens. Through that we determined the limitation of gypsum concrete in building works.
    [Show full text]
  • Proportioning the Key to Achieving a Strong, Durable Concrete Rests in the Careful Proportioning and Mixing of the Ingredients
    Wej-it Fastening Systems Technical Manual Note: the information and data contained herein was current as of November 2008. However, the material is subject to change and is updated as needed. Wej-it Fastening Systems reserves the right to change designs and specifications without notice or liability for such changes. Please contact Wej-it Fastening Systems or look us up on www.wejit.com for the most current data available. BASE MATERIAL CONCRETE In its simplest form, concrete is a mixture of paste and aggregates. The paste, composed of Portland cement and water, coats the surface of the fine and coarse aggregates. Through a chemical reaction called hydration, the paste hardens and gains strength to form the rock-like mass known as concrete. Within this process lies the key to a remarkable trait of concrete: it's plastic and malleable when newly mixed, strong and durable when hardened. These qualities explain why one material, concrete, can build skyscrapers, bridges, sidewalks, superhighways, houses and dams. Proportioning The key to achieving a strong, durable concrete rests in the careful proportioning and mixing of the ingredients. A concrete mixture that does not have enough paste to fill all the voids between the aggregates will be difficult to place and will produce rough, honeycombed surfaces and porous concrete. A mixture with an excess of cement paste will be easy to place and will produce a smooth surface; however, the resulting concrete is likely to shrink more and be uneconomical. A properly designed concrete mixture will possess the desired workability for the fresh concrete and the required durability and strength for the hardened concrete.
    [Show full text]
  • HA T·.Hesis Eubn:Lt.T:Ed L:1 Ra:R:I
    CALH'ORI:\IIA S'l'ATE UNIVERSITY 1 NORI'HIUDGE 'l'IIE HIS'l'ORY 0'"' CONCRB1'E FROH ROI-.!AN 'I'JJ,!E.S H TO 'l'HE EIGH'l.'BEl\!TH CEl\'l'URY A t·.hesis EUbn:Lt.t:ed L:1 ra:r:i:·.J..al sat:i.sfacti..on of the :t··f~(Jnix·enlC~!·~:.s fer t.£~·2 d.E:g~~c;e of X1la.st.er oE A.rt.s i~1 1\Tt hy Jum:>. 1979 The 'l'hes:i.s of Janet Irene Atkinson is approved: -;.=:----~-~r-------:.--r---:::_-.--.-~- -- -~ ~-'r. Rpqer [,_t,Jul_~.o •" Dr. Jean-LtlC Bordeaux. ---------~~·---· Dr. Donald S. Strong, Chairman -~~-----· California State University, Northrid<Jc ACKNOWLEDGMENTS I wish to thank my Father from whom I heard my first stories regarding concrete construction; Dr. Strong for his tireless patience; Charlotte Oyer, Librarian, loTho was able to locate many rare references; and Linda Hartman for t.yping this paper. iii TABLE OF' CONTENTS Page J~IST OF' ILLUSTRATIONS • v GLOSSARY viii ABSTRAC'r xvii INTRODUCTION . •. .. " . 1 Chapter I. THE :LEGl~CY OF' ROME 9 II. THE \1\JA:'NING OF' CONCRETE AECHITECTURE 46 III. THE REVIVAL OF CONCRE'rE IN EUROPEAN AECHITEC'lUHI~ 83 136 BIBLIOGRhPHY 146 iv LIST OF ILLUSTRATIONS Figure Page 1. Map . • . 6 .2. Specimen of Mortars from Egypt:, Greece, Italy and Cyprus, 18 65 . • . ~ • • • • 13 3. Map of Italy 18 4. "Example of Poured Concrete 24 5. Use of Iron in Antiquity 27 6. ~l'emple of Castor 30 7. 'I'emple of 117 B.C.
    [Show full text]
  • USG Rehabilitation Guidelines for Damaged Gypsum Underlayments Technical Guide (English)
    USG Tile & GUIDELINES Flooring Solutions USG REHABILITATION GUIDELINES FOR DAMAGED GYPSUM UNDERLAYMENTS POURED GYPSUM FLOORS IN The use of poured gypsum floors began in the early 1970s as a substitute for light-weight concrete. MULTI-FAMILY STRUCTURES The need for either gypsum or light-weight concrete is based on building codes that require all multi-family wood-frame buildings provide a one-hour fire rating. Both gypsum and light-weight concrete products act as a heat sink that in turn delivers a one- or two-hour rated assembly. Poured gypsum concrete is beneficial for a few reasons: 1. Reduction in thickness. Poured gypsum can be poured at a minimum of ¾ in. (19 mm) instead of the 1-1/2 in. (38 mm) that light-weight concrete requires. 2. Poured gypsum sets and develops strength very quickly which can allow trade traffic to resume in as little as one day. All multi-family structures must be designed in accordance with the requirements of Underwriters Laboratory (UL) for fire-resistance. UL has created a library of floor-ceiling assembly specifications that are used by architects and code bodies to identify the exact methodology needed to construct the floor-ceiling assembly. Therefore, it is imperative that any repair/rehabilitation performed on a multi-family dwelling conform to UL standards. This means that the minimum thickness of the poured gypsum underlayment must be maintained at no less than ¾ in. (19 mm) using a UL Classified product. There are no maximum thickness limits specified by UL. Gypsum floors are installed by adding water and sand to a specially formulated gypsum binder powder at the jobsite.
    [Show full text]
  • Heat-Insulating Gypsum Based Plaster Compositions
    Lyashenko, T.; Kersh, V.; Kolesnikov, A. Heat-insulating gypsum based plaster compositions 1. Introduction When developing lightened heat-insulating materials on the base of calcium sulphate (increasingly important in construction) the possibilities to introduce various lightweight aggregates and the limits of their content have been studied [1, 2]. The purpose of this particular study has been to develop the compositions for interior plaster coverings, with fine perlite as basic filler. It is known that entering of perlite grains (of low thermal conductivity) in gypsum matrix can significantly improve heat and sound insulation properties of the composite, with not only its density being lowered, but, unfortunately, its strength as well. To strengthen the composite a part of perlite could be replaced with cenospheres. These hollow alumina-silica microspheres (formed as a part of fly ash) are known [3-6] as efficient filler due to their form, waterproofness, low density and thermal conductivity. The preliminary experiments showed that certain dosages of metakaolin, plasticiser and latex could improve gypsum matrix, structure and properties of the composite. 2. Preliminary trials To determine the upper limit of the content of heat-insulating component the method of electro-thermal analogy was used in preliminary model experiments. The method helps to establish the proportions in "conductor − insulator" systems, at which the electrical conductivity changes abruptly; percolation conductivity jump takes place (or percolation resistance jump at certain content of insulator). The conductive media was modelled with carbon powder, lightweight filler particles served as the insulator. The estimated value of percolation threshold for perlite grains (and for cenospheres as well), near 80 volume percents (Fig.
    [Show full text]
  • Gypsum Powder Recycled from Waste Drywalls As a Partial Cement Replacement in Concrete
    GYPSUM POWDER RECYCLED FROM WASTE DRYWALLS AS A PARTIAL CEMENT REPLACEMENT IN CONCRETE by Sarah Kathleen Aubierge Hansen Submitted in partial fulfilment of the requirements for the degree of Master of Applied Science at Dalhousie University Halifax, Nova Scotia March 2020 © Copyright by Sarah Kathleen Aubierge Hansen, 2020 DEDICATION I would like to dedicate this thesis to my mother, Kathy, who always encourages me to be my best and shows me immeasurable love and support. ii TABLE OF CONTENTS List of Tables ............................................................................................................ vi List of Figures ......................................................................................................... vii Abstract .................................................................................................................... x List of Abbreviations and Symbols Used .................................................................. xi Acknowledgements.................................................................................................. xiii Chapter 1 Introduction ........................................................................................ 1 1.1 General ................................................................................................................ 1 1.2 Research Objectives ............................................................................................ 1 1.3 Thesis Structure .................................................................................................
    [Show full text]
  • Background Facts and Issues Concerning Cement and Cement Data
    Background Facts and Issues Concerning Cement and Cement Data By Hendrik G. van Oss Open-File Report 2005-1152 U.S. Department of the Interior U.S. Geological Survey ii U.S. Department of the Interior Gale A. Norton, Secretary U.S. Geological Survey P. Patrick Leahy, Acting Director For product and ordering information: World Wide Web: http://www.usgs.gov/pubprod Telephone: 1-888-ASK-USGS For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment: World Wide Web: http://www.usgs.gov Telephone: 1-888-ASK-USGS Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Although this report is in the public domain, permission must be secured from the individual copyright owners to reproduce any copyrighted material contained within this report. iii Preface This report is divided into two main parts. Part 1 first serves as a general overview or primer on hydraulic (chiefly portland) cement and, to some degree, concrete. Part 2 describes the monthly and annual U.S. Geological Survey (USGS) cement industry canvasses in general terms of their coverage and some of the issues regarding the collection and interpretation of the data therein. The report provides background detail that has not been possible to include in the USGS annual and monthly reports on cement. These periodic publications, however, should be referred to for detailed current data on U.S. production and sales of cement. It is anticipated that the contents of this report may be updated and/or supplemented from time to time.
    [Show full text]
  • Cast-In-Place Concrete 033000 - 1
    JAMESTOWN CSD Lincoln Elementary Alterations 73654.01 CAST-IN-PLACE CONCRETE 033000 - 1 SECTION 033000 - CAST-IN-PLACE CONCRETE PART_1_-_GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this section. 1.2 SUMMARY: A. Extent of cast-in-place concrete work is indicated on drawings and in provisions of this section. B. Concrete work includes, but is not limited to: 1. Footings & foundation walls. 2. Concrete slabs on ground as indicated on drawings. 3. Curing compound. 4. Slots, inserts, anchors, ties. 5. Preformed expansion joint fillers. 6. Set built-in items furnished by others. 7. Other concrete work indicated on drawings and/or specified therein (except as otherwise specified). 1.3 RELATED WORK: A. Excavating,_Filling_and_Grading as specified in Division 31. B. Concrete_Reinforcement as specified in another Division 3 section. C. Unit_Masonry as specified in Division 4. D. Structural_Steel as specified in Division 5. 1.4 QUALITY ASSURANCE: A. Use latest edition, including all addenda, revisions and supplements for all specifications, standards, and codes, referred to herein. B. Applicable Standards: 1. American Society for Testing Materials (ASTM): C-31 Making and Curing Concrete Test Specimens In the Field. C-33 Specification for Concrete Aggregates. C-39 Test for Compressive Strength of Cylinder Concrete Specimens. C-42 Obtaining and Testing Drilled Cores and Sawed Beams of Concrete. C-94 Specifications for Ready-Mixed Concrete. C-138 Test for Unit Weight, Yield and Air Content (Gravimetric) of Concrete. C-143 Test for Slump of Portland Cement Concrete.
    [Show full text]
  • Chapter Iud 53
    DEPT. OF INDUSTRY, LABOR & HUMAN RELATIONS 47 Structural Chapter Iud 53 STRUCTURAL REQUIREMENTS Ind 53.001 Floor, roof and side­ Ind 63.10 Non bear i ng masonry walk loads walls Ind 53.01 Wind pressure Ind 53.11 Cavity walls Ind 53.02 Foundations Ind 63.12 Bonding and anchor­ Ind 53.03 Masonry construction; ing stone and cast general requirement stone veneers Ind 53.04 Ashlar and rubble ma­ Ind 63.13 Parapet walls sonry Iud 63.14 Concrete requirements Ind 53.05 Building bricl{ Iud 63.16 Rei n for c e d gypsum Ind 63.06 Hollow building units concrete Ind 63.07 Allowable unit stresses Ind 63.16 Structural steel in masonry Ind 63.17 Steel joist construction Ind 53.08 Mortar and grout Ind 63.18 ,Vrougl1t Iron Ind 63.09 Bearing masonry walls, Ind 63.19 Cast iron bearing partitions aud Ind 53.20 Wood construction piers Ind 53.001 Floor, roof and sidewalk loads. (1) DEAD LOADS. All buildings and structures, and parts thereof, shall be designed and constructed to support in addition to the minimum superimposed live loads specified in this section, the actual dead weight of all component members; and in addition thereto, an allowance for the weight of partitions, ceiling and floor finish, and concentrated loads such as safes, mechanical apparatus and similar equipment. (2) LIVE LOADS. All buildings and structures, and parts thereof, shall be designed and constructed to support the following minimum superimposed live loads uniformly distributed in pounds per square foot of horizontal area in addition to the dead load: (a) Theaters and assembly halls with fixed seats: 1.
    [Show full text]
  • Conejo Recreation and Park District Alex Fiore Teen Center and Goebel
    Job Name: Alex Fiore Teen Center and Goebel Adult Center Job Number: 1642-01-RC19 TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS 01 4525 Testing, Adjusting, and Balancing For HVAC 01 5713 Temporary Erosion and Sediment Control DIVISION 02 - EXISTING CONDITIONS 02 4100 Demolition 02 4119 Selective Structure Demolition DIVISION 03 - CONCRETE 03 0000 Concrete Work-General 03 0516 Underslab Vapor Barrier - Stego 03 1000 Concrete Forming and Accessories 03 2000 Concrete Reinforcing 03 3000 Cast-in-Place Concrete 03 3511 Concrete Floor Finishes DIVISION 04 - MASONRY 04 2000 Unit Masonry DIVISION 05 - METALS 05 5000 Metal Fabrications 05 7513 Decorative Metal Perforated Panels DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES 06 1000 Rough Carpentry 06 2000 Finish Carpentry 06 4100 Architectural Wood Casework 06 8316 Fiberglass Reinforced Paneling DIVISION 08 - OPENINGS 08 0671 Door Hardware Schedule 08 1213 Hollow Metal Frames 08 1400 Wood Doors DIVISION 09 - FINISHES 09 0561 Common Work Results for Flooring Preparation 09 0562 Remedial Floor Coating 09 2116 Gypsum Board Assemblies 09 3000 Tiling 09 5100 Acoustical Ceilings 09 6429 Wood Strip and Plank Flooring 09 6500 Resilient Flooring 09 6813 Tile Carpeting 8/11/2021 5:01 PM Table of Contents Page 1 of 3 Job Name: Alex Fiore Teen Center and Goebel Adult Center Job Number: 1642-01-RC19 09 7819 Plastic Laminate Faced Paneling 09 9113 Exterior Painting 09 9123 Interior Painting 09 9750 Anti-Graffiti Coating DIVISION 10 - SPECIALTIES 10 2113.17 Phenolic Toilet Compartments 10 2233 Accordion
    [Show full text]