Gas Blending Systems

Total Page:16

File Type:pdf, Size:1020Kb

Gas Blending Systems GAS BLENDING SYSTEMS 657 SERIES BLENDMASTER 1750 The BlendMaster 1750 Series mixer precisely blends shielding gas for GMAW (MIG) and GTAW (TIG) welding. Argon-Carbon Dioxide mixes are consistently delivered to those industrial applications requiring repeatability and control. Available in wall or floor mount and 120 volt or 220 volt configuration, the BlendMaster 1750 delivers the flexibility that yields a low cost of ownership. Advanced Features Pressure Equalization Technology Maintains mix accuracy under fluctuating supply conditions 0-25% Ratio Adjustment Ensures 1,750 SCFH for all mixes Gas Piloted Dual-Dome Technology Maintains mix accuracy by eliminating pressure decay at high-flows 6700 Series Line Regulator Delivers stable pressure control at high-flows Applications Materials Specifications GMAW (MIG) Welding Case Flow Capacity 0-10% Carbon Dioxide Mild Steel Powder-coated steel 1750 SCFH (50.0 M³/H) Deep penetrating spray transfer Surge Tank Inlet Supply Pressure Requirements 15-25% Carbon Dioxide Mild Steel Powder-coated steel 100 - 125 PSIG (7 - 8.6 BAR) Spatter-free short arc transfer Regulator Mixed Gas Outlet Pressure Brass barstock 10 - 50 PSIG (.7 - 3.5 BAR) Seals Power Requirements Neoprene 110 or 220 VAC (50 - 60 Hz) 40-Micron Inlet Filter Temperature Range 316L stainless steel 32°F to 100°F (0°C to 38°C) Inlet and Outlet Fittings Accuracy Brass ± 1.5% Weight 102 lbs. (46 kg) Surge Tank 7 gallon (26.5 Liters) BLENDERS GAS BLENDING SYSTEMS Single Stage Installation Dimensions Stage Dual Control Flow Pipeline Cylinder Liquid Special Use T Cutting orches Attachments & Handles Floor-Mounted Wall-Mounted Cutting T ips Heating T ips Ordering Information Series Major Gas Minor Gas Monitoring* Assembly 657 1: Argon 2: Carbon Dioxide 0: No Alarm 1: 110V Floor Mount Outfits 7: Low Pressure Alarm Capable* 2: 110V Wall Mount 5: 220V Floor Mount 6: 220V Wall Mount Accessories * Remote alarm not included. Flowcur ves Related Options Part Number Option Description 575 0025-01-000 Altos 2 Alarm Provides real-time cylinder pressure, audible and visual notification of a depleted supply bank to a remote location. (See page 46 for full list of options).
Recommended publications
  • Escherichia Coli HD701
    The Process Intensification of Biological Hydrogen Production by Escherichia coli HD701 By Michael Sulu A thesis submitted to The University of Birmingham for the degree of DOCTOR OF PHILOSOPHY School of Chemical Engineering College of Engineering and Physical Sciences The University of Birmingham November 2009 University of Birmingham Research Archive e-theses repository This unpublished thesis/dissertation is copyright of the author and/or third parties. The intellectual property rights of the author or third parties in respect of this work are as defined by The Copyright Designs and Patents Act 1988 or as modified by any successor legislation. Any use made of information contained in this thesis/dissertation must be in accordance with that legislation and must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the permission of the copyright holder. Abstract Hydrogen is seen as a potential fuel for the future; its choice is driven by the increasing awareness of the necessity for clean fuel. Together with the simultaneous development of “green technologies” and sustainable development, a current goal is to convert waste to energy or to create energy from a renewable resource. Biological processing [of renewables] or bioremediation of waste to create hydrogen as a product fulfils this goal and, as such, is widely researched. In this work, an already established process, using a hydrogenase up‐regulated strain ‐ was characterised and the important process parameters were established. This bacterial strain has the potential for industrial‐scale hydrogen production from, for example, waste sugars. Previous work, repeated here, showed that hydrogen could be generated by E.
    [Show full text]
  • Professional and Honor Program - Descriptions with Prerequisite Requirements
    Professional and Honor Program - Descriptions with Prerequisite Requirements Professional Career Programs - Full Residence Honor Programs The Professional Career Programs provide broad training for students seeking Short Residence with Self Study Prep rewarding, full-time employment in the recreational diving industry. Both The Institute's Honor programs are shortened versions of our full residence full-residence individual skill and combination skill programs are available. “Professional” Instructor, Divemaster /Dive Control Specialist and Rescue Areas covered in professional programs are: skin and scuba diving instruc- training modules. We designed the “Honor” Programs to give credit for tion, divemaster supervision and dive control specialist, boatmaster, under- certain types of previous training from diver to divemaster and for using our water digital photography and videography with computer editing, promo- self study package to help prepare before attendance. tional diving video-DVD-CD and photo production, detailed dive business, store and resort operations, diving business sales and persuasion, diving Honor program entry requirements are a lot stiffer than our longer full equipment overhaul and repair technology, deep and technical diving residence “Professional” programs. They also do not include the broad instruction, semi-closed or closed circuit rebreather instruction, diving variety of training and practice available in our more extensive "Professional" specialties instruction, submersibles and underwater communication tech- programs. nology, air station and technical gas blending operations, professional CPR- People attending shorter Honor Programs, need to be self-motivated with First Aid, and diving accident response technology and instruction. excellent reading and math skills. Most Honor Programs have physical and Making a good living in the recreational diving industry generally requires written attendance qualification exams to test your preparedness before you more abilities than just teaching.
    [Show full text]
  • A Gas Dilution System for Arsine-Air Mixtures
    NBSIR 73-260 A Gas Dilution System for Arsine-Air Mixtures Peter A. Pella, Ernest E. Hughes, and John K. Taylor National Bureau of Standards Department of Commerce Washington, D. C. 20234 October 1973 Final Report Prepared for National Institute for Occupational Safety and Health Division of Laboratories and Criteria Development Cincinnati, Ohio 45202 NBSIR 73-260 A GAS DILUTION SYSTEM FOR ARSINE-AIR MIXTURES Peter A. Pella, Ernest E. Hughes, and John K. Taylor National Bureau of Standards Department of Commerce Washington, D. C. 20234 October 1973 Final Report Prepared for National Institute for Occupational Safety and Health Division of Laboratories and Criteria Development Cincinnati, Ohio 45202 I U. S. DEPARTMENT OF COMMERCE, Frederick B. Dent, Secretary NATIONAL BUREAU OF STANDARDS, Richard W. Roberts, Director A Gas Dilution System for Arsine-Air Mixtures ABSTRACT A gas -blending system originally designed for chlorine-air mixtures was modified for producing arsine-air mixtures in the concentration range from 0.02 to 0.25 ppm. This system has been tested in order to provide accurately known concentrations of arsine- in-air for calibration of analytical monitor- ing devices. An analytical method has been developed for checking the concentration of arsine in the work- ing standard and consists of the spectrophotometric measurement of an arsine-diethyldithiocarbamate complex in solution. 1. INTRODUCTION The system originally designed for preparing chlorine- air mixtures [1] has been adapted for producing arsine-air mixtures in the range from 0.02 to 0.25 ppm. The system combines a gas blending unit and an analytical unit. The gas blending unit produces concentrations of arsine by dilu- tion of a relatively high concentration of arsine in nitrogen (i.e.
    [Show full text]
  • 15. Advanced Gas Blender
    TDI Standards and Procedures Part 2: TDI Diver Standards 15. Advanced Gas Blender 15.1 Introduction This course enables the successful candidate to engage in the blending of oxygen and helium based gasses. The objective of this course is to train candidates in the proper procedures needed for the preparation and blending of high quality nitrox and trimix gases for use in technical diving. 15.2 Qualifications of Graduates Upon successful completion of this course candidates will be able to prepare high quality scuba gases. 15.3 Who May Teach Any active TDI Advanced Gas Blending Instructor may teach this course 15.4 Student to Instructor Ratio Academic 1. Unlimited, so long as adequate facility, supplies and time are provided to ensure comprehensive and complete training of subject matter Confined Water (swimming pool-like conditions) 1. N/A Open Water (ocean, lake, quarry, spring, river or estuary) 1. N/A 15.5 Student Prerequisites 1. Minimum age 18 2. Provide proof of certification as a TDI Nitrox Gas Blender or equivalent Version 0221 113 TDI Standards and Procedures Part 2: TDI Diver Standards 15.6 Course Structure and Duration Open Water Execution 1. N/A Course Structure 1. TDI allows instructors to structure courses according to the number of students participating and their skill level Duration 1. The minimum number of classroom and briefing hours is 6 15.7 Administrative Requirements The following are the administrative tasks: 1. Collect the course fees from all the students 2. Ensure that the students have the required equipment 3. Communicate the training schedule to the students 4.
    [Show full text]
  • Diving Air Compressor - Wikipedia, the Free Encyclopedia Diving Air Compressor from Wikipedia, the Free Encyclopedia
    2/8/2014 Diving air compressor - Wikipedia, the free encyclopedia Diving air compressor From Wikipedia, the free encyclopedia A diving air compressor is a gas compressor that can provide breathing air directly to a surface-supplied diver, or fill diving cylinders with high-pressure air pure enough to be used as a breathing gas. A low pressure diving air compressor usually has a delivery pressure of up to 30 bar, which is regulated to suit the depth of the dive. A high pressure diving compressor has a delivery pressure which is usually over 150 bar, and is commonly between 200 and 300 bar. The pressure is limited by an overpressure valve which may be adjustable. A small stationary high pressure diving air compressor installation Contents 1 Machinery 2 Air purity 3 Pressure 4 Filling heat 5 The bank 6 Gas blending 7 References 8 External links A small scuba filling and blending station supplied by a compressor and Machinery storage bank Diving compressors are generally three- or four-stage-reciprocating air compressors that are lubricated with a high-grade mineral or synthetic compressor oil free of toxic additives (a few use ceramic-lined cylinders with O-rings, not piston rings, requiring no lubrication). Oil-lubricated compressors must only use lubricants specified by the compressor's manufacturer. Special filters are used to clean the air of any residual oil and water(see "Air purity"). Smaller compressors are often splash lubricated - the oil is splashed around in the crankcase by the impact of the crankshaft and connecting A low pressure breathing air rods - but larger compressors are likely to have a pressurized lubrication compressor used for surface supplied using an oil pump which supplies the oil to critical areas through pipes diving at the surface control point and passages in the castings.
    [Show full text]
  • General Training Standards, Policies, and Procedures
    General Training Standards, Policies, and Procedures Version 9.2 GUE General Training Standards, Policies, and Procedures © 2021 Global Underwater Explorers This document is the property of Global Underwater Explorers. All rights reserved. Unauthorized use or reproduction in any form is prohibited. The information in this document is distributed on an “As Is” basis without warranty. While every precaution has been taken in its preparation, neither the author(s) nor Global Underwater Explorers have any liability to any person or entity with respect to any loss or damage caused or alleged to be caused, directly or indirectly, by this document’s contents. To report violations, comments, or feedback, contact [email protected]. 2 GUE General Training Standards, Policies, and Procedures Version 9.2 Contents 1. Purpose of GUE .............................................................................................................................................6 1.1 GUE Objectives ............................................................................................................................................. 6 1.1.1 Promote Quality Education .................................................................................................................. 6 1.1.2 Promote Global Conservation Initiatives .......................................................................................... 6 1.1.3 Promote Global Exploration Initiatives ............................................................................................. 6
    [Show full text]
  • Case Study: Membrane Co2 Removal from Natural Gas, Grissik Gas Plant, Sumatra, Indonesia
    CASE STUDY: MEMBRANE CO2 REMOVAL FROM NATURAL GAS, GRISSIK GAS PLANT, SUMATRA, INDONESIA Charles L. Anderson Air Liquide – MEDAL, L.P. Newport, Delaware 19804 USA (1) 302 225-2102 [email protected] Anggiat Siahaan ConocoPhillips Jakarta, Indonesia (62) (21) 524-1987 [email protected] Abstract One of the world’s largest membrane systems is used for bulk removal of CO2 from natural gas at the Grissik gas processing plant in South Sumatra, Indonesia. The membrane system processes 310 MMSCFD of natural gas, reducing CO2 from 30% to 15%. The Grissik plant is termed a membrane plus amine hybrid which offers particularly attractive operational benefits. The membrane system has been operating for more than four years with no membrane replacement and offers the benefit of very long membrane life. CASE STUDY: MEMBRANE CO2 REMOVAL FROM NATURAL GAS, GRISSIK GAS PLANT, SUMATRA, INDONESIA Charles L. Anderson, Air Liquide – MEDAL, L.P., Newport, Delaware, USA Anggiat Siahaan, ConocoPhillips, Jakarta, Indonesia Introduction ConocoPhillips operates the Grissik gas processing plant on behalf of its partners, Talisman Energy Inc., Pertamina and BPMigas. The Grissik plant, located in South Sumatra, Indonesia, pictured in Figure 1, processes 310 MMSCFD of natural gas, primarily reducing CO2 concentration from 30% in the raw feed down to 3% in the sales gas. Figure 1. Grissik Gas Plant Process Overview The Grissik plant CO2 removal process utilizes both membrane separation and amine absorption technology, termed a membrane plus amine hybrid. A simplified process flow diagram is shown in Figure 2. The Thermal Swing Adsorption (TSA) removes heavy hydrocarbons, serving the triple function of membrane pre-treatment, feed gas dehydration and sales gas hydrocarbon dew pointing.
    [Show full text]
  • TDI Advanced Nitrox Diver
    TDI Advanced Nitrox Diver Are you looking to expand your dive time? Maybe you’re a scientific diver or photographer looking to stay in the water a little longer?The TDI Advanced Nitrox Course qualifies divers to use enriched air nitrox from EAN 21 through EAN 100 percent within your current certification level to a maximum depth of 40 metres/130 feet during dives that do not require staged decompression. Often taught in conjunction with the TDI Decompression Procedures course, this can be considered the foundation of your technical diving career. TDI Advanced Nitrox is also a must for SCR or CCR divers. Who this course is for: • The certified nitrox diver looking to expand their understanding of nitrox mixtures containing more than 40% oxygen • The certified nitrox diver looking to expand their in-water skills • The certified diver who has interest in moving forward with technical diving education Course prerequisites (these requirements must be met prior to the start of the course): • Minimum age 18, 15 with parental consent • Minimum certification of TDI Nitrox Diver or equivalent • Proof of 25 logged open water dives What you can expect to learn: Advanced Nitrox picks up where TDI Nitrox leaves off and offers a more in-depth look at diving with nitrox including: • Physics and physiology relating to diving with gas mixes containing more than 40% oxygen • Gas planning, dive tables, dive computers, oxygen limitations, nitrogen limitations • Equipment considerations, cylinder labeling, analyzing nitrox mixtures, gas blending procedures,
    [Show full text]
  • Preparation of Calibration and Control Standards Using a Multi-Component Gas Blending and Dilution System
    MLD074 Revision 1.0 Approval Date: August 13, 2019 TABLE OF CONTENTS 1. SCOPE………………………………………………………………………………………1 2. SUMMARY OF METHOD ......................................................................................... 1 3. ACRONYMS ............................................................................................................. 1 4. INTERFERENCES AND LIMITATIONS ................................................................... 2 5. PERSONNEL QUALIFICATIONS AND TRAINING .................................................. 3 6. SAFETY REQUIREMENTS ...................................................................................... 3 7. HAZARDOUS WASTE ............................................................................................. 4 8. EQUIPMENT AND SUPPLIES ................................................................................. 4 9. PROCEDURES ........................................................................................................ 5 10. QUALITY CONTROL ................................................................................................ 6 11. CALCULATIONS ...................................................................................................... 8 12. DATA MANAGEMENT ............................................................................................. 9 13. MAINTENANCE AND REPAIRS .............................................................................. 9 14. TROUBLESHOOTING .............................................................................................
    [Show full text]
  • A Novel Perspective to Calibrate Temporal Delays in Cerebrovascular Reactivity Using Hypercapnic and Hyperoxic Respiratory Challenges
    NeuroImage 187 (2019) 154–165 Contents lists available at ScienceDirect NeuroImage journal homepage: www.elsevier.com/locate/neuroimage A novel perspective to calibrate temporal delays in cerebrovascular reactivity using hypercapnic and hyperoxic respiratory challenges Allen A. Champagne a,1, Alex A. Bhogal b,2, Nicole S. Coverdale a,1, Clarisse I. Mark a,3, Douglas J. Cook a,c,* a Centre for Neuroscience Studies, Queen's University, Kingston, ON, Canada b Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands c Department of Surgery, Queen's University, Kingston, ON, Canada ARTICLE INFO ABSTRACT Keywords: Redistribution of blood flow across different brain regions, arising from the vasoactive nature of hypercapnia, can Cerebrovascular reactivity introduce errors when examining cerebrovascular reactivity (CVR) response delays. In this study, we propose a Temporal delays novel analysis method to characterize hemodynamic delays in the blood oxygen level dependent (BOLD) response Hypercapnia to hypercapnia, and hyperoxia, as a way to provide insight into transient differences in vascular reactivity be- Hyperoxia tween cortical regions, and across tissue depths. A pseudo-continuous arterial spin labeling sequence was used to BOLD signal acquire BOLD and cerebral blood flow simultaneously in 19 healthy adults (12 F; 20 Æ 2 years) during boxcar Cerebral blood flow CO and O gas inhalation paradigms. Despite showing distinct differences in hypercapnia-induced response delay RIPTiDe 2 2 times (P < 0.05; Bonferroni corrected), grey matter regions showed homogenous hemodynamic latencies (P > 0.05) once calibrated for bolus arrival time derived using non-vasoactive hyperoxic gas challenges. Longer hy- percapnic temporal delays were observed as the depth of the white matter tissue increased, although no signif- icant differences in response lag were found during hyperoxia across tissue depth, or between grey and white matter.
    [Show full text]
  • Producing Clean Fuel Gas On-Site
    IMPROVE GAS TURBINE/ENGINE PERFORMANCE AND REDUCE MAINTENANCE USING MEMBRANES FOR FUEL GAS CONDITIONING Authors: Sachin Joshi, Hesham Hussain, Priyanka Tiwari, Daaniya Rahman, and Tim Aldajani Membrane Technology and Research, Inc. 39630 Eureka Drive, Newark, CA 94560, Tel: (650) 543-3357 [email protected] ABSTRACT Unprocessed raw natural gas is the major source of fuel for turbines/engines in power generation and compression applications in many condensates rich shale gas plays such as Marcellus, Utica, Bakken, Eagle Ford and Niobrara. When raw natural gas containing heavy and sour gas is used as fuel for powering turbines and engines, serious damage is caused to their components, thereby reducing efficiencies and in some cases complete equipment shutdown. This has an immediate impact on oil and gas production leading to substantial losses in revenues. This paper describes the use of unique heavy hydrocarbons and acid gas-permeable membranes to produce clean fuel gas from raw shale gas. Numerous fuel gas conditioning membrane units have been installed around the world by companies like Marathon Oil, Markwest Energy, Williams Energy, EQT Corp., Chevron for reducing the heavy & sour contents from raw gas. The key advantage of using membranes for clean fuel gas is its simplicity in operation. The membranes are passive units with no moving parts. No pre-treatment is required for their operation except for standard filtration. The units are designed for unattended operator attention and are virtually maintenance-free. The membranes work on the principle of passing heavy hydrocarbons, acid gases and water through the membranes, leaving a clean gas to be used as fuel.
    [Show full text]
  • Standards for Scientific Diving Certification and Operation 0507420, 04/24/19
    THE UNIVERSITY OF MAINE ORGANIZATIONAL MEMBER OF THE AMERICAN ACADEMY OF UNDERWATER SCIENCES STANDARDS FOR SCIENTIFIC DIVING Revised February 2019 Campus: The University of Maine System / Safety Management Page 1 Document: Dive Safety Program – Standards for Scientific Diving Certification and Operation 0507420, 04/24/19 TABLE OF CONTENTS Section Page Forward ........................................................................................................................................................... 4 Acknowledgments ......................................................................................................................................... 4 Adoption and Approval ............................................................................................................................... 4 Revision History ............................................................................................................................................ 6 1 General Policy ....................................................................................................................................... 7 1.1 Scientific Diving Standards ......................................................................................................... 7 1.2 Operational Control ..................................................................................................................... 8 1.3 Consequence of Violation of Regulations by Scientific Divers ........................................... 11 1.4 Consequences of Violation
    [Show full text]