Ethernet Twisted Pair Cable Categories
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
The Twisted-Pair Telephone Transmission Line
High Frequency Design From November 2002 High Frequency Electronics Copyright © 2002, Summit Technical Media, LLC TRANSMISSION LINES The Twisted-Pair Telephone Transmission Line By Richard LAO Sumida America Technologies elephone line is a This article reviews the prin- balanced twisted- ciples of operation and Tpair transmission measurement methods for line, and like any electro- twisted pair (balanced) magnetic transmission transmission lines common- line, its characteristic ly used for xDSL and ether- impedance Z0 can be cal- net computer networking culated from manufactur- ers’ data and measured on an instrument such as the Agilent 4395A (formerly Hewlett-Packard HP4395A) net- Figure 1. Lumped element model of a trans- work analyzer. For lowest bit-error-rate mission line. (BER), central office and customer premise equipment should have analog front-end cir- cuitry that matches the telephone line • Category 3: BWMAX <16 MHz. Intended for impedance. This article contains a brief math- older networks and telephone systems in ematical derivation and and a computer pro- which performance over frequency is not gram to generate a graph of characteristic especially important. Used for voice, digital impedance as a function of frequency. voice, older ethernet 10Base-T and commer- Twisted-pair line for telephone and LAN cial customer premise wiring. The market applications is typically fashioned from #24 currently favors CAT5 installations instead. AWG or #26 AWG stranded copper wire and • Category 4: BWMAX <20 MHz. Not much will be in one of several “categories.” The used. Similar to CAT5 with only one-fifth Electronic Industries Association (EIA) and the bandwidth. the Telecommunications Industry Association • Category 5: BWMAX <100 MHz. -
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category 3 circuit for voice and one Category 5e circuit for data. Category 3 cables consisted of four loosely twisted pairs of copper conductor under an overall jacket and were tested to 16 megahertz. Category 5e cables, on the other hand, had its four pairs more tightly twisted than the Category 3 and were tested up to 100 megahertz. The design allowed for voice on one circuit and data on the other. As network equipment data rates increased and more network devices were finding their way onto the network, this design quickly became obsolete. Companies wisely began installing all Category 5e circuits with often three or more circuits per work area outlet. Often, all circuits, including voice, were fed off of patch panels. This design allowed information technology managers to use any circuit as either a voice or a data circuit. Overbuilding the system upfront, though it added costs to the original project, ultimately saved money since future cable additions or cable upgrades would cost significantly more after construction than during the original construction phase. By installing all Category 5e cables, they knew their infrastructure would accommodate all their network needs for a number of years and that they would be ready for the next generation of network technology coming down the road. Though a Category 5e cable infrastructure will safely accommodate the widely used 10 and 100 megabit-per-second (Mbits/sec) Ethernet protocols, 10Base-T and 100Base-T respectively, it may not satisfy the needs of the higher performing Ethernet protocol, gigabit Ethernet (1000 Mbits/sec), also referred to as 1000Base-T. -
HLE-1 HDMI Extender System Installation Manual
HLE-1 HDMI Extender System Installation Manual HDBaseT IR Out HDBaseT IR Out HLE-1 TX HDMI Extender with HDBaseT-Lite™ Transmitter HLE-1 RX HDMI Extender with HDBaseT-Lite™ Power In + 24VDC Only Power Receiver HDMI IR In HDMI In HDBT Power HDMI HDMI IR In Out HDBT HLE-1 Installation Manual Table of Contents Introduction . 3 Kit Contents . 4 Feature Set . 5 Specifications . 6 Transmitter Connections . 7 Reciever Connections . 8 Transmitter Functions . 9 Receiver Functions . 10 IR Connection Diagrams . 11 Troubleshooting . 12 Warranty . 12 2 HLE-1 Installation Manual Introduction INTRODUCTION Thank you for purchasing Transformative Engineering’s HLE-1 HDMI Extender Kit. This product incorporates many advanced technologies to accomplish 1.4a HDMI compliant extension of the High Definition MultiMedia Interface protocol over one length of Category 5e/6/7 wire. Among these is certified HDBase-T technology, licensed here. This unique conversion of HDMI signals provides for the most reliable, stable and predictable method to transfer all HDMI requirements. More information on this technology may be found at the HDBase-T website, www.hdbaset.org . We are proud to be an early Adopter Member of the Alliance. Proper connection and attention to limitations of this product will provide secure, reliable, and predictable results. The most important variable to success will depend on wire chosen as the interconnection between our Transmitter and Receiver. All Category wire is not created equal. It is vital that care is taken at all times to avoid kinks, crimps, nicks, and other abuse of the wire and jacket. Also, we highly recommend that all wire be sweep tested before and after installation to insure full bandwidth is not impaired. -
Catv Cabling System
NYULMC AMBULATORY CARE CENTER – FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: 032698.000 Issued for GMP March 15, 2017 SECTION 27 41 33 CATV CABLING PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Furnish and install a complete and fully operational Television Signal Distribution System capable of delivering up to 158 video channels (6 MHz NTSC Channels containing NTSC, ATSC and QAM modulated programs) and IP Video over an installed Category 6A unshielded twisted pair cable system. The System shall utilize a cable plant comprised of a TIA/EIA 568 compliant horizontal distribution cable system and a coaxial and/or single mode fiber backbone system. The System shall employ Active Automatic Gain Control Electronics to adjust the video signal levels to each TV and shall be capable of supporting up to 14,000 connected devices. The System shall support bi-directional RF transmission for backbone interconnections. Include amplifiers, power supplies, cables, outlets, attenuators, hubs, baluns, adaptors, transceivers, and other parts necessary for the reception and distribution of the local CATV signals. Back-feed existing campus system. (CAT 5e is acceptable to 117 channels) B. Distribute cable channels to TV outlets to permit simple connection of EIA standard Analog/Digital television receivers. C. Deliver at outlets monochrome and NTSC color television signals without introducing noticeable effect on picture and color fidelity or sound. Signal levels and performance shall meet or exceed the minimums specified in Part 76 of the FCC Rules and Regulations D. Provide reception quality at each outlet equal to or better than that received in the area with individual antennas. -
HD Television on Cat 5/6 Cable Cable TV on Cat 5/6 Cable
HD Television on Cat 5/6 Cable Cable TV on Cat 5/6 Cable Innovative Technology .... Exceptional Quality! The Lynx® Television Network Distributes up to 640 digital Increases flexibility for moves, adds channels on Cat 5 or Cat 6 cable and changes Excellent for cable TV, SMATV, or Improves reliability off-air television distribution Creates a technology bridge to Simplifies cabling requirements Internet TV and IPTV The Lynx Television Network simultaneously simplifies installation, standardizes the wiring, delivers up to 210 HDTV channels, 640 and reduces maintenance requirements. standard digital channels, or 134 analog channels on Cat 5 or Cat 6 cable. Frequency The Lynx Network increases system flexibility capabilities are 5 MHz to 860 MHz. because moves, adds, and changes are easy with Cat5/6 cable. A Lynx hub in the wiring closet converts an unbalanced coaxial signal into eight or A homerun wiring design improves reliability sixteen balanced signals transmitted on because there are no taps or splitters between twisted pair cables. At the point of use a the distribution hub and the TV. wallplate F or single port converter changes the signal back to coaxial form. The Lynx Network also provides a “technology bridge” to Internet TV and IPTV by setting up the cabling that these technologies use. A patented RF balun is the centerpiece of the Lynx design. A pair of send / receive baluns delivers a clean RF signal to each TV (on pair four). The baluns use an RF technology that delivers HD, digital, and analog channels on network cables without using any bandwidth Wallplate F Single port converter on the network itself. -
Introduction to Digital Subscriber's Line (DSL) Chapter 2 Telephone
Introduction to Digital Subscriber’s Line (DSL) Professor Fu Li, Ph.D., P.E. © Chapter 2 Telephone Infrastructure · Telephone line dates back to Bell in 1875 · Digital Transmission technology using complex algorithm based on DSP and VLSI to compensate impairments common to phone lines. · Phone line carries the single voice signal with 3.4 KHz bandwidth, DSL conveys 100 Compressed voice signals or a video signals. 1 · 15% phones require upgrade activities. · Phone company spent approximately 1 trillion US dollars to construct lines; · 700 millions are in service in 1997, 900 millions by 2001. · Most lines will support 1 Mb/s for DSL and many will support well above 1Mb/s data rate. Typical Voice Network 2 THE ACCESS NETWORK • DSL is really an access technology, and the associated DSL equipment is deployed in the local access network. • The access network consists of the local loops and associated equipment that connects the service user location to the central office. • This network typically consists of cable bundles carrying thousands of twisted-wire pairs to feeder distribution interfaces (FDIs). Two primary ways traditionally to deal with long loops: • 1.Use loading coils to modify the electrical characteristics of the local loop, allowing better quality voice-frequency transmission over extended distances (typically greater than 18,000 feet). • Loading coils are not compatible with the higher frequency attributes of DSL transmissions and they must be removed before DSL-based services can be provisioned. 3 Two primary ways traditionally to deal with long loops • 2. Set up remote terminals where the signals could be terminated at an intermediate point, aggregated and backhauled to the central office. -
Retrospective on Development of Radio and Wire Data Communication
March, 2006 IEEE P802.15-06-0107-00-wng0 IEEE P802.15 Wireless Next Generation Networks Project IEEE P802.15 Working Group for Wireless Personal Area Networks (WPANs) Title Retrospective on Development of Radio and Wire Data Communication Date 4 March 2006 Submitted Source Chandos A. Rypinski Voice: +1.415.435.0642 consultant Fax: [- ] Tiburon, CA 94920 USA E-mail: [email protected] Re: Call for contributions for 15WNG Erik Schylander, 13 Feb 2006 Abstract An account of: the development of phase shift keying and orthogonal frequency division multiplex with carriers positioned at spectral null of the adjacent carrier at Collins Radio 1954-58, the early development of 802.3 CSMA, 802.4 Token bus and 802.5 Token ring and the 802.4L radio PHY for token bus, the 802.6 and 802.9 committee’s working on voice-data integration, the start of 802.11 from 802.4L, the original functional targets and the DFW MAC adopted as a starting point the circumstances for the development 11A and 11B. Purpose The intent is show the effect of early and current decision-making as influenced by function goals and obscure design considerations. Possibly some future choices may be better made with knowledge of these examples. Notice This document has been prepared to assist the IEEE P802.15. It is offered as a basis for discussion and is not binding on the contributing individual(s) or organization(s). The material in this document is subject to change in form and content after further study. The contributor(s) reserve(s) the right to add, amend or withdraw material contained herein. -
Digital Subscriber Lines and Cable Modems Digital Subscriber Lines and Cable Modems
Digital Subscriber Lines and Cable Modems Digital Subscriber Lines and Cable Modems Paul Sabatino, [email protected] This paper details the impact of new advances in residential broadband networking, including ADSL, HDSL, VDSL, RADSL, cable modems. History as well as future trends of these technologies are also addressed. OtherReports on Recent Advances in Networking Back to Raj Jain's Home Page Table of Contents ● 1. Introduction ● 2. DSL Technologies ❍ 2.1 ADSL ■ 2.1.1 Competing Standards ■ 2.1.2 Trends ❍ 2.2 HDSL ❍ 2.3 SDSL ❍ 2.4 VDSL ❍ 2.5 RADSL ❍ 2.6 DSL Comparison Chart ● 3. Cable Modems ❍ 3.1 IEEE 802.14 ❍ 3.2 Model of Operation ● 4. Future Trends ❍ 4.1 Current Trials ● 5. Summary ● 6. Glossary ● 7. References http://www.cis.ohio-state.edu/~jain/cis788-97/rbb/index.htm (1 of 14) [2/7/2000 10:59:54 AM] Digital Subscriber Lines and Cable Modems 1. Introduction The widespread use of the Internet and especially the World Wide Web have opened up a need for high bandwidth network services that can be brought directly to subscriber's homes. These services would provide the needed bandwidth to surf the web at lightning fast speeds and allow new technologies such as video conferencing and video on demand. Currently, Digital Subscriber Line (DSL) and Cable modem technologies look to be the most cost effective and practical methods of delivering broadband network services to the masses. <-- Back to Table of Contents 2. DSL Technologies Digital Subscriber Line A Digital Subscriber Line makes use of the current copper infrastructure to supply broadband services. -
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve Derose’S Guide to CAT5 Network Wiring (See Later Web Reference)
Ethernet/Category 5 Network Cabling Guide Prepared by SJ Wilkinson (August 2002) Based on Steve DeRose’s Guide to CAT5 Network Wiring (See later Web Reference) Networks A Local Area Network (LAN) can be as simple as two computers, each having a network interface card (NIC) or network adapter and running network software, connected together with a crossover cable. Here the crossover cable would have a plug at either end to connect into the NIC socket at the back of each computer. The next step up would be a network consisting of three or more computers and a hub. Each of the computers is plugged into the hub with a straight-thru cable (the crossover function is performed by the hub). For a small network the straight-thru cables would have plugs at either end – one to connect to the computer and one to the hub. For larger networks wall cabling, wall sockets and patch cables are used. A CAT5 "patch panel" is used at the hub end where all your wires come together and provides a group of sockets for further cables. Straight-thru patch cables connect computers to sockets (jacks). Straight-thru wall cables connect sockets to the patch panel. Straight-thru patch cables connect the patch panel to the hub. Patch panels often make network cabling neater but are not essential as (a) wiring a plug is no harder than wiring a panel; (b) you still need cables to go from the panel to the hub; and (c) it adds extra connections, so lowers reliability. 1 Planning your Network Pick a location for your hub, preferably centred to keep cable runs shorter. -
Dodea FACILITIES MANAGEMENT GUIDE
DoDEA FACILITIES MANAGEMENT GUIDE: TECHNOLOGY SYSTEMS DESIGN GUIDELINES DoDEA-NETWORK VERSION 2.0 DEPARTMENT OF DEFENSE EDUCATION ACTIVITY APRIL 14, 2016 UPDATED DRAFT DoDEA Technology Systems Design Guide – DoDEA Network Requirements TABLE OF CONTENTS Acronyms ........................................................................................................................................ 3 1.0 Purpose ........................................................................................................................ 5 2.0 Applicability ................................................................................................................. 5 3.0 References ................................................................................................................... 5 4.0 Responsibilities ............................................................................................................ 7 5.0 Data/Telecommunications Systems Summary ............................................................. 8 5.1 Outside Cable Plant .................................................................................................... 10 5.2 System Requirements ................................................................................................ 11 5.2.A Main Telecommunications Room (TR1) ........................................................................... 11 5.2.B Secondary Telecommunications Room (TR2) ................................................................... 13 5.2.C Video Distribution ............................................................................................................ -
Modeling and Estimation of Crosstalk Across a Channel with Multiple, Non-Parallel Coupling and Crossings of Multiple Aggressors in Practical PCBS
Scholars' Mine Doctoral Dissertations Student Theses and Dissertations Fall 2014 Modeling and estimation of crosstalk across a channel with multiple, non-parallel coupling and crossings of multiple aggressors in practical PCBS Arun Reddy Chada Follow this and additional works at: https://scholarsmine.mst.edu/doctoral_dissertations Part of the Electrical and Computer Engineering Commons Department: Electrical and Computer Engineering Recommended Citation Chada, Arun Reddy, "Modeling and estimation of crosstalk across a channel with multiple, non-parallel coupling and crossings of multiple aggressors in practical PCBS" (2014). Doctoral Dissertations. 2338. https://scholarsmine.mst.edu/doctoral_dissertations/2338 This thesis is brought to you by Scholars' Mine, a service of the Missouri S&T Library and Learning Resources. This work is protected by U. S. Copyright Law. Unauthorized use including reproduction for redistribution requires the permission of the copyright holder. For more information, please contact [email protected]. MODELING AND ESTIMATION OF CROSSTALK ACROSS A CHANNEL WITH MULTIPLE, NON-PARALLEL COUPLING AND CROSSINGS OF MULTIPLE AGGRESSORS IN PRACTICAL PCBS by ARUN REDDY CHADA A DISSERTATION Presented to the Faculty of the Graduate School of the MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY In Partial Fulfillment of the Requirements for the Degree DOCTOR OF PHILOSOPHY in ELECTRICAL ENGINEERING 2014 Approved Jun Fan, Advisor James L. Drewniak Daryl Beetner Richard E. Dubroff Bhyrav Mutnury 2014 ARUN REDDY CHADA All Rights Reserved iii ABSTRACT In Section 1, the focus is on alleviating the modeling challenges by breaking the overall geometry into small, unique sections and using either a Full-Wave or fast equivalent per-unit-length (Eq. PUL) resistance, inductance, conductance, capacitance (RLGC) method or a partial element equivalent circuit (PEEC) for the broadside coupled traces that cross at an angle. -
KNOW the LINGO – WHAT IS Category CABLE?
KNOW THE LINGO – WHAT IS CategoRY CABLE? By: Joseph D. Cornwall, CTS-D Technology Evangelist—Lastar, Inc. Technical lingo is a kind of shorthand that’s used to express concepts common to that specific topic or area of study. Technical lingo is important because it provides a very precise or unique “shorthand” description of a device, effect or concept. Unfortunately, if you aren’t comfortable and familiar with the lingo of a topic it can be a tall hurdle to communicate efficiently with folks who consider the jargon of their field to be “self-explanatory.” In this series of articles we’ll lift the veils of misunderstanding from the lingo of the A/V industry. WHAT IS A CAT CABLE? The concept of Category cables was first set forth by the Electronic Industries Alliance (EIA) and is now maintained by the Telecommunications Industry Association (TIA). In 1991 the TIA/EIA-568-A standard was released (now revised to TIA/EIA-568-C) in an effort to define standards for telecommunications installations. In particular, the standard worked to define elements of balanced twisted pair cabling, fiber optic cabling and coaxial cabling, along with the associated connectors. The Cat cables discussed here are of the unshielded twisted pair (UTP) variety. You can’t be in the A/V or IT industry and not have heard of Cat5e and Cat6 cables. The Cat, as you might know, is short for “Category.” The term “Category” refers to the different levels of performance in signal bandwidth, attenuation and crosstalk associated with each cable’s design.