R-4 Indoor Infrared Heater with PCO AIR PURIFIER and HUMIDIFIER
Total Page:16
File Type:pdf, Size:1020Kb
R-4 Indoor Infrared Heater WITH PCO AIR PURIFIER and HUMIDIFIER Thanks for choosing the RedCoreTM Indoor Infrared Heater! We help our customers save money on energy bills while improving their comfort with safe, therapeutic heating products. The RedCore™ Concept R4 is a 3-in-1 product, producing soft infrared heating, humidification, and superior year-round air purification all in one convenient product. PRECAUTION WARNING 1: WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS. WARNING 2: RISK OF ELECTRIC SHOCK NO USER-SERVICABLE PARTS INSIDE EXCEPT TO CLEAN THE AIR FILTER AND ADD WATER TO THE HUMIDIFIER. 1. Read all instructions before using this appliance. 2. The heater is hot when in use. To avoid burns, do not place any objects such as furniture, papers, clothes, and curtains closer than 3 feet (0.9 m) to the front of the heater and keep them away from the sides and rear when the heater is plugged in. 3. Extreme caution should be taken when using any appliance around children, elderly, or disabled persons, or whenever the heater is operating unattended. Children under 14 years of age should not be allowed to operate this heater. This product is for adult use only and all children must be supervised when using this product. 4. Always unplug heater when not in use. 5. Do not operate heater with a damaged cord or plug, after the heater malfunctions, or if the heater has been dropped or damaged in any manner. Discard heater or return to an authorized service facility for examination and/or repair. 6. Do not use outdoors. 7. This heater is not intended for use in bathrooms, laundry areas, and similar indoor locations. Never locate appliance where it may fall into a bathtub or other water container. 8. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic areas and where it will not be tripped over. 9. To disconnect the appliance, turn controls to off, wait for heater to cool down and shut off, and then remove plug from outlet. 10. Connect to properly polarized outlets only. This product requires a three prong outlet with ground. 11. Do not insert or allow foreign objects to enter into ventilation opening as this may cause an electric shock, fire or damage the appliance. 12. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked. 13. The heater has hot parts and sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored. 14. Use this appliance only as described in this manual. Any use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. 15. Always plug heaters directly into a wall outlet receptacle. Do not use an extension cord. 16. To prevent overload and blown fuses, be sure that no other appliance is plugged into the same outlet on the same circuit. 17. It is normal for the heater’s plug and cord to feel warm to the touch. A plug or cord which becomes hot to the touch or becomes distorted in shape may be a result of a worn electrical outlet (receptacle). Worn outlets or receptacles should be replaced prior to further use of the heater. Plugging this heater into a worn outlet (receptacle) may result in overheating of the power cord or fire. 18. Be sure that the plug is fully inserted into an appropriate receptacle. Please remember that receptacles also deteriorate due to aging and continuous use: check outlet and cord periodically for signs of overheating or deformations of the plug. If any overheating or deformation is present, immediately discontinue using the receptacle and contact a qualified electrician. 19. CAUTION: To prevent electric shock, match wide blade of plug to wide slot of receptacle and insert completely. 20. Do not cover the appliance while it is functioning in order to avoid overheating and/or risk of fire. 21. Do not place the heater near a bed because objects such as pillows or blankets can fall off the bed and be ignited by the heater. 22. Check your heater cord and plug connections. a) Faulty wall outlet connections or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight in outlet. b) Heaters draw more current than small appliances. Overheating of the outlet may occur even if it has not occurred with the use of other appliances. c) During use, check frequently to determine if your plug outlet or faceplate is HOT! d) If so, discontinue use of the heater and have a qualified electrician check and/or replace faulty outlet(s). 23. Do not locate against walls or behind drapes or furniture. 24. Be certain to clean the outer air filter in the rear of the heater periodically by vacuuming it and/or washing it to remove dust particles. Be certain to dry the filter completely prior to reinserting it into its position on the heater and prior to re-starting the heater. SAVE THESE INSTRUCTIONS Product specification and basic features Voltage 120V-60HZ Heating power: Up to1500 Watts. Temperature control range:60-90 degrees Fahrenheit Heating element: Infrared PTC heater Air purifier: lifetime washable air filter and PCO cell Humidifier: ultrasonic atomized design with separate control from heater operation Delay Timer: 1-23 hour delay time setting for heater LCD display and touch button operation, including remote control Tip-over safety switch… automatically shuts off heater if it tips over Coverage: Up to 1,000 square feet. Dimensions:17.8” high X 13.9” wide X 16.5” deep 16.54 Weight: 29.5 pounds Main Features ON/OFF (I/O) switch located back of unit Humidifier water tank LCD Display Humidifier air outlet Hot air outlet Wireless receiver Casters LCD display and button instruction Power On/Off button: Turn on or turn off the heater Humidifier On/Off button: Turn on or turn off the humidifier function Room Setting button: Set the room size according to actual size of room and the heater will work at different power levels based on different room size settings: larger room =1500 Watts; medium room = 1000 Watts; small room = 500 Watts. Heater On/Off button: Turn on or turn off the heating function of the heater Temperature Up/Down button: Adjust the desired temperature from 60-90*F. (Note: LCD will show target and actual temperature.) Fan Adjust button: Adjust the fan to function at High or Low mode Delay Timer Setting button: Set the delay timer from 1-23 hours before heater turns on. Purifier Indication: Indicates that the air purifier is working Humidifier and Add Water mode: indicates that the humidifier is working. When water is lower than water line, LCD will display Add Water mode. The humidifier will stop automatically when Add Water mode activates Heating Up mode: Indicates the heater is heating up. (Note: the fan will not operate while the heater is heating up.) Cooling Down mode: Indicates the heater is cooling down. (Note: the fan will automatically turn off when the heater has completed its cool down function.) Remote- Control unit How to Operate the Heater Un-package heater: cut open tape area, fold back flaps and gently turn entire box upside down. Lift box from Styrofoam packing. Remove Styrofoam, turn upright. We recommend keeping the package for off-season storage and any transporting needs. Position: Find a level and unobstructed location to place the unpackaged heater. Plug in: Plug the power cord directly into an unused grounded 120 volt 15 amp or higher circuit receptacle. Power switch: Press down the power switch located on the rear of the heater to the ON position (I). Power On unit: After pressing down the POWER button to turn on the heater, the default setting of the heater will be the Air Purifier is ON. The UV lamp will work to purify the room. The LCD will show the actual room temperature. Heater ON/OFF: Press the HEATER power button to turn on or off the heating function of the heater. The fan will not operate until the heating element has reached a temperature high enough to begin the warming process. During the period that the fan will not work, the message “HEATING UP” will show on the LCD display to indicate that the heater is heating up. When the user presses the HEATER button, if the actual room temperature is higher than the default setting temperature of ”70F”, the heater will not start heating and LCD will show ”COOLING DOWN.” Adjust the desired temperature up to a number higher than the actual room temperature. Room Setting: Press the ROOM SETTING button to adjust the power level based on the room size. The heater has 3 power settings and can be used for Small, Medium and Large sized rooms as follows: Small = 500 Watts; Medium = 1000 Watts; Large= 1500 Watts. Temperature setting: Press the TEMP UP or TEMP DOWN button to set the desired temperature. The temperature range is 60-90*F. By pressing the HEATER button, the heater will default to the pre-set temperature of 70*F. Humidifier setting: Press the HUMIDIFIER button to turn on/off the humidifier. Press the humidifier button once and the unit will begin to produce humidity until the water is used up.