Careplus™ Authorised Distributor: Product Catalogue CCONTENTONTENT
Total Page:16
File Type:pdf, Size:1020Kb
www.niq-health.com USA oce UK – Europe oce Australia oce 1000N West Street, Suite 1200 16 Upper Woburn Place Unit 1 / 11 Howe Street Wilmington London WC1H 0AF Osborne Park, Perth Delaware 19801 Western Australia 6017 t: +1 302 295 4845 t: +44 20 7193 0072 t: +61 8 9446 8499 e: [email protected] e: [email protected] e: [email protected] CarePlus™ Authorised Distributor: Product Catalogue CONTENTC ONTENT 08 Central Control Module (CCM) 2-32-3 CCM License Keys/Interfaces 4-74-7 Nursecall Interface Module (NIM) 8-98-9 Master Audio Visual Interface Module (MAVIS) 10-1110-11 24 12 Entertainment Handset 12-1312-13 Patient && StaffStaff StationStation / /Call Call Point Point (Antimicrobial (Dry Area) Single and Dual Priorities) 14-1514-16 Patient && StaffStaff StationStation / /Call Call Point Point (Austco (Wet/Protected Compatible) Area) 16-1716-17 Patient && StaffStaff StationStation / /Call Call Point Point (Dry (UK Area) Style Single and Double) 18-1918-19 MobilePatient Connect& Staff Station / Call Point (Wet/Protected Area) 20-2120-21 OverPatient Door & Staff / Cooridor Station Light / Call Point (UK Style Single and Double) 22-2322 CarePlus™Mobile Connect Reporting Module 24-2523 CarePlus™ Whiteboard Module 2426 20 PatientCarePlus™ Entertainment Reporting Module Systems 2527 15 PullCarePlus™ Cord Call New Point Patient Care Experience 28-2926 DementiaPull Cord Call Control Point System (DCS) 2730 CarePlus™Dementia Control Alert System (DCS) 28-2931 Disabled Toilet Kit 3032 24V Battery BackedBacked PowerPower SupplySupply 3133 16 PendantsOver Door / Cooridor Light 3234 DutyTV Interface Station & Corridor Signs 3235 IPPendants Pager Transmitters 3236 ProtocolDuty Station Converter & Corridor Signs 3236 36 TVIP PagerInterface Transmitters 3236 22 Protocol Converter 36 1 CENTRAL CONTROL MODULE (CCM) » Technical Data » CarePlus™ CCM Standard CarePlus™ CCM Part : CCM-G-R-STD CCM-G-DT-STD : CCM Desktop Style Number CCM-G-R-STD : CCM Rack Style The CarePlus™ CCM is a message routing module with built-in workflow Ambient Temperature : 0 - 50ºC (20-90% RH non condensing) Both licensed for: associated with nurse call, paging endcoder, alarm management and Storage temperature : -10 - 60ºC (10-95% RH non - CarePlus™ Base Software (room controllers / NIM various forms of messaging protocol inputs and outputs. Messages can range condensing) and call points) - BestLite LED Sign Management be routed to and from any port. A multi-user multilingual web browser Type of protection : IP 30 - Date and Time for signs BestLite above Material : Metal Rack interface provides generalised messaging and configuration. - Nurse allocation (dynamic - standard) Client Colour : Blue software GUI Fixing / mounting : Rack Mount - Active Alarm Client Dimensions : L: 455mm W: 205mm D: 45mm - TAP interface (Standard 19in Rack Mount) - 3 users / 200 contacts Features Details Weight : Approx. 2700g - POCSAG interface Ethernet connection Up to 32 Nurse Call Interface Modules (NIMs) can be connected Paging output to a ward based CCM 3x Communication ports (RS232) 1x Communication port (RS485) CCMs can be networked together Mains powered to share paging, messaging, Rack or desk mountable reporting and alarm handling Simple web interface (GUI) Flexible and powerful processing Visual configuration file ability Excel / CSV configuration LISTED © MET VDE US UL1069 The CarePlus™ CCM is FDA, UL 1069 and DIN 0834 certified, and meets AS3811. 2 3 CarePlus™ CCM » Nurse Allocation Defined (Advanced) Interface License Keys / Interfaces CCM-G-LK-3 : Nurse allocation enables rosters to be allocated i.e. day shift, night shift. Enables nurses to be allocated to rooms or beds, devices to be allocated to nurses and automatic escalations. Advanced refers to the ability to allocate individually or » Swing Room Functionality via automated rosters and enables dynamic changes to active rosters. CCM-G-LK-1 : Links two Care Areas / wards together enabling one nurse station at night-time. Also enables individual rooms to be moved from one area to another expanding one ward and decreasing the other wards rooms. The swing of rooms or all rooms automatically moves Live Nurse Allocation all messages / alarms (audio, visual and paging) to the designated master nurse station. Allows ward overflow of rooms / beds from Remove Assignment donor ward facilitating flexible work flow and bed management. Staff Members Locations Primary Secondary Tertiary Bird, Tessa A Admin Interview Bird, Tessa Brown, Lisa Brown, Lisa Room 1 Brown, Lisa A Admin Interview Brown, Lisa Bird, Tessa King, Eric Room 2 Donnel, George A Admin Interview King, Eric King, Eric Bird, Tessa Room 3 Green, Harry A Admin Interview King, Eric Bird, Tessa King, Eric Room 4 James, Jackie A Admissions Reception Moore, Charlotte Johnston, Amber King, Eric Johnston, Amber A Block Consult Moore, Charlotte Johnston, Amber Bird, Tessa Reception King, Eric A Consult 01 Lee, Rachel Johnston, Amber Nguyen, Bao Lee, Rachel A Consult 02 Lee, Rachel Bird, Tessa Bird, Tessa A Consult 03 Edit Staff Schedule Evening » White Board Sign for Alarm Display - Per White Board Schedule Name Auto Start by Time Start Time 12 : 00 AM End Time 8 : 00 AM CCM-G-LK-2 : The white board is an Internet Explorer based visualisation of the active alarms. This can be shown in Graphical or Text mode. Remove Assignment Staff Members Locations Primary Secondary Tertiary Bird, Tessa A Admin Interview Bird, Tessa Lee, Rachel Peters, Angeline Room 1 Brown, Lisa A Admin Interview Bird, Tessa Lee, Rachel Peters, Angeline Room 2 Donnel, George A Admin Interview Bird, Tessa Lee, Rachel Peters, Angeline Room 3 Green, Harry A Admissions Reception Bird, Tessa Lee, Rachel Peters, Angeline James, Jackie A Consult 01 James, Jackie Moore, Charlotte No Assignment Johnston, Amber Staff Allocation Status Current Schedule Dynamic Current Assignments Primary Contact Secondary Contact Tertiary Contact Room 1 No Assignment Rye, Sue Door, Fay Bed 1 Pager 1 Room 1 Rye, Sue Rye, Sue Door, Fay Bed 2 Pager 1 Room 1 Rye, Sue Rye, Sue Door, Fay Bed 3 Pager 1 Room 1 Rye, Sue Rye, Sue Door, Fay Bed 4 Pager 1 Room 1 Rye, Sue Ward, Jenny No Assignment Bed 5 Pager 2 Room 1 Door, Fay Ward, Jenny No Assignment Bed 6 Pager 1 Pager 2 Bird, Tessa 4 5 » Dual Poling Line » TRM Interface » Hyper Terminal Script » Reminder Messages (purchase protocol converter additionally - part CCM-LK-11 : Please contact NiQ Health for more CCM-LK-21 : This script was developed so that CCM-LK-31 : This feature allows staff to set up no. PC-1) details customers could HyperTerminal (telnet) ongoing regular messages to staff / into CarePlus™ to send messages to contacts. Messages can be sent hourly, CCM-G-LK-29 : Enables one CCM to have additional recipients. daily, weekly, monthly or annually. NIMs addressed. Enables NIMs 16 to 31. » ESPA Interface CCM-LK-12 : A bidirectional interface to 3rd party » Cisco Call Manager 4.1 and 6.1 » Extra Concurrent User 1 - » Sedco Backward Compatibility Option products (paging systems) enabling CCM to send and receive messages CCM-LK-22 : Interface to Cisco Call Manager IP Max. 9 Concurrent Users licensable CCM-G-LK-32 : Enables the CCM to directly connect to these 3rd party products. (A telephony. Sends text style messages CCM-User : CarePlus™ Lite has 1 concurrent user or to legacy Sedco 3000 and Sedco 6000 European standard for paging, building to Cisco handsets via nurse allocation seat licence. CarePlus™ standard has 3 installations. management and fire systems) feature, uses rosters and allocation of licences or 3 seats. CarePlus™ can have device to bed or to room with multiple up to 9 concurrent users or seats. » BestLite Interface » KIRK - Standard with 8 Contacts beds. Provides dynamic acceptance or escalation message status in reporting CCM-G-LK-33 : Interfaces for the BestLite single and CCM-LK-13 : Interface to Kirk digital telephony. Sends and on white boards to assist with » Extra Contacts (Recipients) x100 double sided duty station/corridor text style messages to Cisco handsets workflow. CCM-Contacts : CarePlus™ is licenced for 200 contacts / signs. via nurse allocation feature, uses rosters recipients / nurses. If additional nurses and allocation of device to bed or to are required to be allocated, buy this » Austco Backward Compatibility Option room with multiple beds. Provides » Generic Input Interface license. dynamic acceptance or escalation CCM-G-LK-34 : Enables the CCM to directly connect to CCM-LK-23 : The Generic in gateway is an extremely message status in reporting and on legacy Austco systems flexible method of passing messages white boards to assist with workflow. from external systems into the » Intelpage IP Interface » Reporting Software - CarePlus™ CCM. CCM-Intel : This interface enables connection to IP » Additional 8 Contacts for KIRK Interface transmitters for radio paging Typical applications include sending fire Including Front End GUI CCM-LK-14 : Base licence provides interface to 8 alarm panel alerts through to pagers : handsets. Buy this licence for another 8 » 3G CCM Interface CCM-LK-4 Displays actual time to respond to and Nurse-call events through to handset licences. patient bedside / room per priority per wireless handsets. Basically any simple CCM-SMS 3G : This is the interface to a Text generator. ward. Enables benchmarking of ward (or not so simple!) incoming text alert The text or SMS generator requires a sim performance to other wards per priority » Additional 8 Contacts for event can be accepted by the Generic card for your local telephone company including graphical comparison. SPECTRALINK Interface gateway and passed out to a multitude and a hardware device. This enables of devices and destinations as text clinicians mobile telephones to receive » Reporting Software Client License CCM-LK-15 : Base licence provides interface to 8 message. automated text messages per alarm via handsets. Buy this licence for another 8 contacts and nurse allocation rosters. CCM-LK-5 : Enables CCM to push data to reporting handset licences.