Wildland Firefighting Gear

Total Page:16

File Type:pdf, Size:1020Kb

Wildland Firefighting Gear Wildland Firefighting Gear Tough Protection for the Harshest Environments Seventy years of dedication to the highest standards is what makes PGI’s broad selection of safety garments unsurpassed in sophistication. From high-tech protection to industry-leading, flame-resistant fabrics, each garment is made with performance details that help keep you protected and ready for anything. PGI™ Fireline™ Ground Pounder™ Classic Coats Stay visible and protected in fire-resistant Indura™ Ultra Soft™, Nomex™ or Tecasafe™ Plus fabric coats, which feature lime-yellow arm bands with 3M™ reflective Scotchlite™ silver stripes across the upper back and arms. Other Features • Alpine-style collar (3.5 in. high) can be worn down or zipped up • Self-locking, two-way, double-pull zipper with double storm-flap • Raglan sleeves • Gusseted sleeve cuff with multi-closure hook-and-loop tabs • Left-chest radio pocket with microphone-holder loop; hook-and-loop flap closure • Two 8 x 8.5 in. (W x H) expandable patch pockets; flap closure secured with hook and loop • U.L. Classified to meet or exceed the current NFPA 1977 standard on Protective Clothing and Equipment for Wildland Fire Fighting • Meets requirements for Cal-OSHA Title 8 GISO Sections 3406 (c)(1) and/or 3410(d)(1) Catalog Number Description List Price 19666164 Classic Coat, Indura Ultra Soft, 9 oz., Yellow $135.61 19666167 Classic Coat, Indura Ultra Soft, 9 oz., Navy $149.17 19666170 Classic Coat, Nomex IIIA, 6 oz., Yellow $165.74 19666173 Classic Coat, Nomex IIIA, 6 oz., Navy $182.39 19666176 Classic Coat, Tecasafe Plus, 7 oz., Yellow $140.48 19666179 Classic Coat, Tecasafe Plus, 7 oz., Navy $154.53 Standard sizes: S, M, L, XL; specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. 1 PGI™ Fireline™ Ground Pounder™ Classic Pants Available in Indura™ Ultra Soft™, Nomex™ or Tecasafe™ Plus fabrics, these pants offer a customized fit and a variety of fire protection features. Other Features • Hook-and-loop closures and metal D-rings to adjust the bottom of the leg opening • Adjustable fabric waistband with elastic back and buckled take-up straps • Zippered front-fly closure is double-needle lockstitched • Extra-deep and contoured front pockets with permanently flame-resistant pocket bags • Two rear, patch-style pockets with hook-and-loop flaps • Two large, pleated cargo pockets at mid-thigh with hook-and-loop flaps • Leg and seat seams sewn and top stitched to eliminate seam failure • U.L. Classified to meet or exceed the current NFPA 1977 standard on Protective Clothing and Equipment for Wildland Fire Fighting • Meets requirements for Cal-OSHA Title 8 GISO Sections 3406 (c)(1) and/or 3410(d)(1) Catalog Number Description List Price 19-666-262 Classic Pants, Indura Ultra Soft, 9 oz., Yellow $136.40 19-666-271 Classic Pants, Nomex IIIA, 6 oz., Yellow $167.64 19-666-280 Classic Pants,Tecasafe Plus, 7 oz., Yellow $147.39 Standard sizes: S, M, L, XL (Waist) Short, Regular, Tall (Length); specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. 2 PGI™ Fireline™ Ground Pounder™ Classic Jumpsuits Designed for speed and ease of movement, these jumpsuits are available in Indura™ Ultra Soft™, Nomex™ or Tecasafe™ Plus fabrics, and feature 2 in. stripes of flame-resistant 3M™ reflective Scotchlite™ in fluorescent lime yellow with a silver stripe lockstitched across the upper back and around the bicep. Other Features • Alpine-style collar (3.5 in. high) can be worn down or zipped up • Two-way, self-locking front zipper extends to top of collar; lockstitched; fabric storm flap with intermittent hook-and-loop closures • Gusseted sleeve cuff with adjustable hook-and-loop tabs • Left-chest radio pocket with hook-and-loop flap; microphone holder loop above the pocket • Extra-deep and contoured front pockets with permanently flame-resistant pocket bags • Two large, pleated cargo pockets at mid-thigh with hook-and-loop flaps • Leg and seat seams sewn and topstitched to eliminate seam failure • U.L. Classified to meet or exceed the current NFPA 1977 standard on Protective Clothing and Equipment for Wildland Fire Fighting Meets requirements for Cal-OSHA Title 8 GISO Sections 3406 (c)(1) and/or 3410(d)(1) Catalog Number Description List Price 19-666-209 Classic Jumpsuits, Indura Ultra Soft, 9 oz., Yellow $229.18 19-666-212 Classic Jumpsuits, Indura Ultra Soft, 9 oz., Green $252.10 19-666-218 Classic Jumpsuits, Nomex IIIA, 6 oz., Yellow $277.75 19-666-221 Classic Jumpsuits, Nomex IIIA, 6 oz., Green $305.52 19-666-227 Classic Jumpsuits, Tecasafe Plus, 7 oz., Yellow $239.10 19-666-230 Classic Jumpsuits, Tecasafe Plus, 7 oz., Green $263.01 Standard sizes: S, M, L, XL (Waist) Short, Regular, Tall (Length); specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. Also available in Navy. 3 PGI™ Fireline™ Smokechaser™ DELUXE Field Coats Wear these coats, available in Indura™ Ultra Soft™, Nomex™ or Tecasafe™ Plus fabrics, during especially harsh conditions for superior ruggedness and flame resistance. No bulky throat strap and closure system required. Other Features • Alpine-style collar (4 in. high) can be worn folded down or zipped up • Seamless shoulders for maximum mobility and reduced wear and seam pressure with harnesses • Double-pull front zipper with storm flap and intermittent hook-and-loop closures • Radio pocket with hook-and-loop flap; microphone holder loop above the pocket • Right-chest cell phone pocket with hook-and-loop flap and a bottom D-ring for gloves or other gear • Adjustable cuffs and partially elasticized wrists • Large, cargo hip pockets with flaps and built-in hand warmer compartments • Right cargo pocket has a nickel-plated swivel snap hook on a 6 in. fabric strap (sewn to inside of pocket) • Flame-resistant, retro-reflective, lime and yellow triple trim around arms, bottom and across upper back • U.L. Classified to meet or exceed the current NFPA 1977 standard on Protective Clothing and Equipment for Wildland Fire Fighting • Meets requirements for Cal-OSHA Title 8 GISO Sections 3406 (c)(1) and/or 3410(d)(1) Catalog Number Description List Price 19666145 Field Coats, Indura Ultra Soft, 9 oz., Yellow $179.62 19666148 Field Coats, Indura Ultra Soft, 9 oz., Navy $197.69 19666151 Field Coats, Nomex IIIA, 6 oz., Yellow $215.70 19666154 Field Coats, Nomex IIIA, 6 oz., Navy $237.27 19666157 Field Coats, Tecasafe Plus, 7 oz., Yellow $187.38 19666160 Field Coats, Tecasafe Plus, 7 oz., Navy $206.11 19666163 Letters, Silver Retro-Reflective, 3 in. High $3.85 Standard sizes: S, M, L, XL; specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. 4 PGI™ Fireline™ Smokechaser DELUXE™ Field™ Jumpsuits Smokechaser DELUXE Jumpsuits, available in Indura™ Ultra Soft™, Nomex™ or Tecasafe™ Plus fabrics, offer complete protection, unsurpassed comfort and unrestricted freedom of movement — all in a convenient, one-piece jumpsuit. Other Features • Generous cut for comfort, ease of movement and layering • Ergonomic sculptured design for a more contoured fit • Articulated elbows and knees promote freedom of movement • Radial sleeve design with full-reach gusseted underarm panels for mobility • Seamless shoulders eliminate seam pressure points when wearing a backpack • Full-length, two-way, self-locking zipper-front closure extends to the top of the collar and is covered by a fabric storm flap, which secures shut with five intermittently spaced hook-and-loop closure systems Catalog Number Description List Price 19666182 Field Jumpsuits, Indura Ultra Soft, 9 oz., Yellow $300.32 19666185 Field Jumpsuits, Indura Ultra Soft, 9 oz., Green $330.36 19666188 Field Jumpsuits, Indura Ultra Soft, 9 oz., Navy $330.36 19666191 Field Jumpsuits, Nomex IIIA, 6 oz., Yellow $351.70 19666194 Field Jumpsuits, Nomex IIIA, 6 oz., Green $386.88 19666197 Field Jumpsuits, Nomex IIIA, 6 oz., Navy $386.88 19666200 Field Jumpsuits, Tecasafe Plus, 7 oz., Yellow $312.45 19666203 Field Jumpsuits, Tecasafe Plus, 7 oz., Green $343.70 19666206 Field Jumpsuits, Tecasafe Plus, 7 oz., Navy $343.70 Standard sizes: S, M, L, XL (Waist) Short, Regular, Tall (Length); specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. 5 PGI™ Fireline™ Double-Duty BDU-Style Pants BDU-style pants, available in Nomex™ or Tecasafe™ Plus fabrics, are comfortable enough to wear around the station, but tough enough to be worn fighting fires. Other Features • Fabric waistband with elastic back; seven belt loops (fit a 2 in. wide belt) • Zippered front fly closure with lockstitching • Sewn using Nomex thread (9 to 10 stiches/inch) • Overlocked and chain stitched seams • Dual classified to meet or exceed the current NFPA 1975 Standard on Emergency Services Work Clothing Elements and the current NFPA 1977 standard on Protective Clothing and Equipment for Wildland Fire Fighting Catalog Number Description List Price 19666100 BDU Pants, Tecasafe Plus, 7 oz., Yellow $159.18 19666106 BDU Pants, Tecasafe Plus, 7 oz., Green $175.10 19666112 BDU Pants, Tecasafe Plus, 7 oz., Navy $175.10 19666118 BDU Pants, Nomex IIIA, 6 oz., Yellow $186.36 19666124 BDU Pants, Nomex IIIA, 6 oz., Green $205.00 19666130 BDU Pants, Nomex IIIA, 6 oz., Navy $205.00 Standard sizes: S, M, L, XL (Waist) Short, Regular, Tall (Length); specify size when ordering. Contact your sales rep for 2XL and 3XL pricing. 6 PGI™ Fireline™ Classic Shirt Jackets Designed using U.S. Forest Service Specifications, these generously patterned shirt jackets allow for unrestricted range of motion and comfort. They can be worn alone as a shirt
Recommended publications
  • Wildland Fire Incident Management Field Guide
    A publication of the National Wildfire Coordinating Group Wildland Fire Incident Management Field Guide PMS 210 April 2013 Wildland Fire Incident Management Field Guide April 2013 PMS 210 Sponsored for NWCG publication by the NWCG Operations and Workforce Development Committee. Comments regarding the content of this product should be directed to the Operations and Workforce Development Committee, contact and other information about this committee is located on the NWCG Web site at http://www.nwcg.gov. Questions and comments may also be emailed to [email protected]. This product is available electronically from the NWCG Web site at http://www.nwcg.gov. Previous editions: this product replaces PMS 410-1, Fireline Handbook, NWCG Handbook 3, March 2004. The National Wildfire Coordinating Group (NWCG) has approved the contents of this product for the guidance of its member agencies and is not responsible for the interpretation or use of this information by anyone else. NWCG’s intent is to specifically identify all copyrighted content used in NWCG products. All other NWCG information is in the public domain. Use of public domain information, including copying, is permitted. Use of NWCG information within another document is permitted, if NWCG information is accurately credited to the NWCG. The NWCG logo may not be used except on NWCG-authorized information. “National Wildfire Coordinating Group,” “NWCG,” and the NWCG logo are trademarks of the National Wildfire Coordinating Group. The use of trade, firm, or corporation names or trademarks in this product is for the information and convenience of the reader and does not constitute an endorsement by the National Wildfire Coordinating Group or its member agencies of any product or service to the exclusion of others that may be suitable.
    [Show full text]
  • Trench Burner Operating Manual for PTO Service and Adjustment on Page 30-33
    Operating Manual T300 Trailer Mounted Trench Burner Equipped With HATZ 4H50 Tier 4F Diesel Engine and Manual PTO “””Better Economically - Better Environmentally” Factory and Main Office Visit Our Website at: Air Burners, Inc. 4390 SW Cargo Way www.AirBurners.com Palm City, FL 34990 Phone: 772-220-7303 or 888-566-3900 FAX: 772-220-7302 E-mail: [email protected] © 1998-2021 Air Burners, Inc. The words Air Burners and the Air Burners Logo are Registered Trademarks of Air Burners, Inc. All Rights Reserved. Subject to change without notice. Dimensions & metric conversions rounded. (Vers. 08.08.2021) T300 Air Curtain Trench Burner with HATZ 4H50 Diesel Engine OPERATING MANUAL The T300 Trench Burner as “Trailer-Mounted Machinery” is offered as “Non-self-propelled Agricultural/Forestry/Construction Equipment” for only incidental On-Road use. WARNING: 1 Should any repairs become necessary that require welding on your T300 Trench Burner, you MUST first physically remove the Electronic Control Module (ECM) from the computer controlled Diesel engine. 1Follow the in- structions below. If you need help, call Customer Support at 772-220-7303. ECM Removal Steps 1. Unsnap Latches 1 and 2 2. Remove Bolts A1 and A2 3. Unplug both connectors 4. Remove Bolts B1, B2, B3 and B4 5. Remove the two brackets 6. The ECM can now be re- moved and stored away 7. Re-install all in reverse order. Page i T300 Air Curtain Trench Burner with HATZ 4H50 Diesel Engine OPERATING MANUAL INDEX WELDING REPAIR WARNING……………………………………………………Page I THE PRINCIPLE OF AIR CURTAIN INCINERATION ..................................... Page 1 GENERAL DESCRIPTION T300 MODEL ......................................................
    [Show full text]
  • Dear Prospective Wildland Fire Fighter Academy Student
    Dear Prospective Wildland Fire Fighter Academy Student: Thank you for your interest in Mendocino College’s Wildland Fire Fighter Academy. The program will begin January 22, 2019. This course will offer basic, entry-level wildland firefighting training for individuals who are seeking a career with state, federal and local fire departments. Upon successful completion of the course students will receive a Cal Fire Basic Firefighter Certificate. The course information is as follows. Please check WebAdvisor for details. Location Course Section Credits Days Hours Howard Forest FSC 68 3242 7.5 MTWThF 0800-1700 Training Center (Willits) A mandatory orientation will be held January 8, 2019, at the Mendocino College Ukiah Campus, Room 4210, for fitting and measuring equipment. The meeting will be from 9am-3pm. In order to enroll in this program you must do the following: o Apply online at www.mendocino.edu or complete the Application for Admission (if you are a continuing student of Mendocino College and have been enrolled in one if the last 2 semesters, this is not necessary). o Obtain a completed Medical Clearance form (attached) and return with a copy of your current Class C California Driver’s License o Return forms to: Mendocino College, Office of Admissions and Records Fax: 707-468-3430 OR Scan/Email: [email protected] Hand Deliver: North County Center, 372 E. Commercial Street Admissions & Records, Ukiah Campus, 1000 Hensley Creek Road Lake Center, 2565 Parallel Drive, Lakeport Coast Center, 1211 Del Mar Drive, Fort Bragg After your prerequisite forms have been received and processed, you will be advised when you can enroll.
    [Show full text]
  • DUPONT™ NOMEX® ARAMID FIBER Laundering Guide TABLE of CONTENTS
    DUPONT™ NOMEX® ARAMID FIBER Laundering Guide TABLE OF CONTENTS Section I: Introduction to DuPont™ Nomex® Aramid Fiber Wash water temperature . 5 General information . 1 Detergents . 5 Section II: Commercial Laundering Garments Made of Water and water conditioners . 5 DuPont™ Nomex® Aramid Fiber Bleaches . 5 Sorting and washer loading . 2 Fabric softeners and anti-stats . 5 Washing supplies . 2 Other washing additives . 6 Detergent . 2 Drying . 6 Alkalinity (pH) . 2 Other drying additives . 6 Bleach . 2 Ironing . 6 Sour . 2 Section IV: Dry Cleaning Garments Made of Softeners, anti-stats and wicking agents . 2 DuPont™ Nomex® Aramid Fiber Non-durable water and oil repellents . 3 General guidelines . 7 Washing procedures . 3 Section V: Removing Spots and Other Non-Standard General wash formulas . 3 Contaminants from Garments Made of DuPont™ Nomex® Wash temperatures . 3 Aramid Fiber Prevention of soil redeposition . 3 General guidelines . 8 Rinsing . 3 Section VI: Appendix Souring . 3 Source list for commercial laundering products . 9 Softeners, anti-stats and wicking agents . 3 Repellents . 3 Drying and finishing . 4 General guidelines . 4 Tumble dry conditioning/finishing . 4 Wet-to-dry type tunnel drying/finishing . 4 Dry-to-dry type tunnel drying/finishing . 4 Pressing . 4 Section III: Home Laundering Garments Made of DuPont™ Nomex® Aramid Fiber General guidelines . 5 Sorting . 5 Pretreating . 5 Preparing the wash load . 5 Load size . 5 Contents SECTION I: INTRODUCTION TO DUPONT™ NOMEX® ARAMID FIBER General information Properly dyed and finished garments made of Nomex® aramid fiber are inherently flame resistant, meaning the flame resistance Nomex® aramid fiber has been used in garments for 50 years for is a permanent or inseparable attribute of the fibers that protection against threats from fire, heat and arc flash.
    [Show full text]
  • College of the Sequoias Firefighter I Academy
    College of the Sequoias Firefighter I Academy Cadet Operations Manual Class #21-35 Spring 2017 Academy Coordinators: Assistant Chief Rick Smith Captain Isaac Buller FIRE ACADEMY STUDENT: READ COMPLETELY, THOROUGHLY, AND CAREFULLY The Academy will begin on Monday, January 9, 2017 at 5:45 pm at the Hanford campus in the Public Safety Building, Room 21. Included is your copy of the Fire Academy Rules and Regulations. You need to carefully and ​ completely read these Rules and Regulations as they identify all of the equipment, material, ​ uniforms, and medical examination requirements. The Rules and Regulations also identify the way the Academy is conducted and the performance that is expected of all Cadets. For those students who will be applying for financial aid, get the process started now! This ​ ​ process takes time, the ordering of your structural firefighting equipment takes time, and your medical examination takes time. All of these things need to be completed before the first day of the Academy. The medical examination takes time to schedule and complete. If you do not have a personal physician, any of the industrial medical groups are capable of performing acceptable medical examinations. When your medical examination has been completed, keep it and bring it ​ ​ with you on the first day of the Academy. Do not mail it in. ​ ​ ​ ​ ​ ​ ​ Academy Overview The College of the Sequoias (COS), Fire Fighter I Academy is offered with the cooperation of the Tulare/Kings Fire Training Officers Association and the Tulare/Kings Fire Chiefs Officers Association. The Academy has a long history at COS with the first class being offered in 1976.
    [Show full text]
  • To Hell and Back Fire Fighter Instructor Outline
    To Hell and Back Fire Fighter Instructor Outline Name: Rank: Employer: Years on the Job: EMT / EMT-A / Paramedic / Fire Fighter / Volunteer Fire Fighter / Career Fire Fighter (Circle all that apply.) Use To Hell and Back as a supplement to the PPE section of any fire fighter safety chapter or module that covers fire fighter training. The objective for classroom instructors is to tailor To Hell and Back to your department. It is suggested that instructors gather burn injury data from their department to include with the classroom presentation. NFPA and OSHA standards are included in FF Training. However, those standards can be expanded upon in a classroom setting. The following outline is only a suggestion for classroom instruction, with an emphasis on PPE. I. Suggested instructor talking points: • This engine pulling out of the bay is an everyday occurrence in today’s fire service. • When the alerting system rings throughout every firehouse, men and women like this crew, kick off their shoes and leave them on the bay floor. They head out those doors to render assistance to what ever emergency they are called to assist. • Every fire fighter expects to return to their shoes when the call is complete. Statistics show that between 100-110 fire fighters per year do not return to fill those shoes. • We know that fighting fires and engaging in emergency operations is a dangerous occupation. • We know that some of the fire fighters that do return are left with pain, emotional suffering, and irreversible physical damage due to sustaining burns while engaging in the occupation.
    [Show full text]
  • Honeywell Safety Products
    >>> FABRIC SELECTOR GUIDE OUTER SHELLS AT A GLANCE KEVLAR® with KEVLAR® with ADVANCE Nomex® III A 2F3 Fabric™ PBI Matrix™ Armor 7.0™ .JMMFOJB95 NOMEX® #BTPÝM® ULTRA™ ATTRIBUTES 93% NOMEX® 60% KEVLAR® 60% KEVLAR® 60% KEVLAR® 45% KEVLAR® 60% KEVLAR® 75% KEVLAR® 60% Technora® 'JCFS$POUFOU 5% KEVLAR® 20% NOMEX® 40% NOMEX® #BTPÝM® 55% NOMEX® 40% PBI 25% NOMEX® 40% PBO 2% Carbon 20% PBO Product Fabric Code CWT A 5 O I 9 Weight (oz/yd2) 7.5 7.5 7.5 7.5 7.0 7.4 7.1 7.5 Weave Plain Ripstop Ripstop Ripstop 3-D Twill Plain Twill Ripstop Spun / Spun / Spun / :BSO Spun Spun Spun Spun Spun .VMUJÝMBNFOU Filament Cables .VMUJÝMBNFOU 5BCFS"CSBTJPO3FTJTUBODF Good Good Moderate Good Moderate Good Good High (ASTM D 3884, H-18 wheel, 500g weight) 5FBS4USFOHUI MCT 50 x 40 35 x 35 30 x 30 45 x 45 40 x 35 50 x 50 90 x 110 90 x 75 (ASTM D 5587) 5FBS4USFOHUIBGUFSIPVSTPG67&YQPTVSF MCT 35 x 20 25 x 25 20 x 20 20 x 20 15 x 20 40 x 40 50 x 60 45 x 45 (CAN/CGSB-4.2 No. 18.3/ISO 105-B02) 5FOTJMF4USFOHUIBGUFS-BVOEFSJOHT MCT 280 x 250 230 x 220 230 x 285 320 x 310 245 x 265 240 x 265 495 x 445 575 x 565 (ASTM D 5034) 5FOTJMF4USFOHUIBGUFSBTFDPOE511&YQPTVSF MCT 30 x 25 55 x 65 30 x 30 215 x 180 40 x 30 60 x 110 170 x 160 320 x 330 3FTJTUBODFUP8BUFS"CTPSQUJPO Good Good Good Good Good Good Good Good .PEJÝFE""5$$ 'MBNF3FTJTUBODF Moderate Good High High Good High High High (ASTM D 6413) 5IFSNBM1SPUFDUJWF1FSGPSNBODF DBMDN2 Tested with NOMEX® on Aramid batting inner liner 39 - 42 39 - 42 46 - 49 40 - 43 39 - 42 38 - 41 39 - 42 39 - 42 (NFPA 1971) 0VUFS4IFMM5IFSNBM%FDPNQPTJUJPO5FNQFSBUVSF Í' 660 - 750 660 - 900 800 - 1000 750 - 1000 660 - 900 800 - 1100 660 - 900 1000 - 1200 1SJDF-FWFM $ $$ $$$ $$$ $$$ $$$$ $$$$ $$$$ Typical values contained herein based on laboratory tests.
    [Show full text]
  • Using Prescribed Fire on Illinois Grasslands
    Using Prescribed Fire on Illinois Grasslands Illinois Ecological Sciences Technical Note No. 2 May 2009 Illinois Ecological Sciences Technical Note No. 2 is intended to be used as a tool to assist in the use of prescribed fire on Illinois grasslands. The two primary reasons for burning grasslands are wildlife habitat improvement and native prairie establishment or restoration. Additional reasons for burning include: to improve forage quality or quantity to improve or manipulate grazing or browsing distribution to remove excess plant litter and wildfire hazard, and to suppress woody plant invasion of grasslands. See Illinois Field Office Technical Guide (FOTG) Standard 338, Prescribed Burning, for a complete list of purposes for conducting a prescribed burn. These guidelines present a set of reasons, criteria, techniques, and examples of simple prescriptions which aid in the planning and execution of a safe and effective prescribed burning program for a variety of purposes in grassland areas of Illinois. Sound planning must be initiated and carried out well in advance, usually 3 to 6 months prior to the scheduled burn. NRCS employees must have the appropriate Job Approval Authority in order to provide technical assistance or participate in any way in prescribed burning. NRCS policies and Job Approval Authority documents may be obtained from the sources listed at the end of the Technical Note. IS FIRE A CHOICE? Illinois grasslands can be managed in different ways; fire is but one possible choice. Other grassland management options include grazing, mowing, haying, fertilization, herbicides, soil scarification (strip disking), interseeding, and total renovation and reseeding. A land manager's first decision is to determine whether fire is a viable option.
    [Show full text]
  • Nomex® Nano Flex Is Revolutionizing Firefighter Hoods
    Emergency response Nomex® Nano Flex is revolutionizing firefighter hoods Firefighters face many hazards on the job. One of the greatest hazards to their long-term health is the unseen threat of harmful particulates. Experts have long agreed that reducing absorption of smoke particles through the skin on the neckline and upper jaw, which are areas that are historically known to be the most vulnerable and least protected, is an essential part of protecting the health of firefighters. Nomex® Nano Flex makes the difference >95% particle barrier Helps improve thermal Thin, lightweight and Highly breathable efficiency protective performance comfortable up to 25% Inherent heat and Maintains durability Inherent protection; Enables situational flame resistance for 25+ washes can’t be washed out or awareness worn away Game-changing protection without compromising comfort Based on the Nomex® brand that has been trusted by firefighters around the world 61% of career for more than 50 years, Nomex® Nano Flex was developed to help make products like firefighter hoods more protective against particulates without compromising thermal resistance, breathability, comfort or situational awareness. firefighter Hoods made with Nomex® Nano Flex are thin, lightweight and highly breathable, allowing air and moisture to move through while preventing harmful particulates line-of-duty from being absorbed through the skin. In addition to the original quilted style, hoods made with Nomex® Nano Flex are deaths now available in a laminated style that offers even greater
    [Show full text]
  • Nuts and Bolts – Again
    Winter 2020 ▲ Vol. 9 Issue 4 ▲ Produced and distributed quarterly by the Wildland Fire Lessons Learned Center 2019 Incident Review Summary Nuts and Bolts – Again By Travis Dotson For more nuts and bolts lessons from real- deal incidents, check out the 2019 Incident his issue of Two More Chains is about things you can do. Actions you can take. Review Summary. Wait, haven’t we done this issue already? Yes we have. (See our Winter 2018 issue of Looking for Refresher training exercises? T Two More Chains.) But guess what? We’re doing it again. Why? This review summary provides multiple exercises related to recent incidents. It’s a Partly because it’s been a whole year and we have a great source for both formal and informal bunch of new reports with new lessons. And also training. Please use it to stimulate dialogue because it’s a new year with new reports and some of among your peers: the very same lessons from previous years. https://www.wildfirelessons.net/viewdocu Hold on. If the Wildland Fire Lessons Learned Center ment/annual-incident-review-summaries (LLC) is getting reports of the very same types of incidents occurring after we put a bunch of effort into sharing the lessons about how to avoid that incident (for instance, the dangers of loose lug nuts) isn’t that proof that what we are doing isn’t working? Maybe. But we don’t often get reports from folks who actually use the lesson. Why? Because using the lesson likely prevents the event that triggers a report.
    [Show full text]
  • Changes for Firefighter Shirts and Pants John Smith and Tony Petrilli, Project Leaders
    United States Department of Agriculture Fire Forest Service Technology & Development Program March 2013 Tech Tips 5100 1351–2309P–MTDC Changes for Firefighter Shirts and Pants John Smith and Tony Petrilli, Project Leaders ince the early 1960s, the U.S. Department of Agricul- ture, Forest Service specification for shirts worn by SSwildland firefighters has gone through several revi- sions. The familiar yellow wildland firefighter shirt will soon have a new look. The new-style shirt has an updated design and will be made with a new fabric. The shirt fabric has remained unchanged since 1992, when the current “Breez- etone” fabric, made of 93 percent meta-aramid, 5 percent para-aramid, and 2 percent carbon fibers (Nomex IIIA), was adopted as the firefighter standard by the Forest Service. 2006 Evaluation Responses In the summer of 2006, the Missoula Technology and Development Center (MTDC) distributed a questionnaire to determine firefighter satisfaction with the current flame-resis- Highlights... tant (FR) shirts made to Forest Service specification 5100-91. FIrefighters returned more than 1,500 questionnaires from 41 • More than 1,500 firefighters responded to States. The firefighter responses provided data on the shirt’s the Missoula Technology and Development fit, comfort, utility, and durability. Analysis of the responses Center 2006 nationwide product review of led to a redesign process aimed at improving the shirt’s fit flame-resistant firefighter shirts. and comfort without losing any usefulness, durability, or pro- • By changing the shirt design and fabric, tection. MTDC’s involvement in accident investigations and firefighters gain a looser fit and more reviews also provides insight into personal protective equip- protection from radiant heat; by changing ment (PPE) designs.
    [Show full text]
  • Evaluation of the Performance of Station Wear Worn Under a NFPA
    TECHNICAL NOTES Evaluation of the Performance of Station Wear W orn under a NFPA 1971 Structural Fire Fighter Protective Ensemble FINAL REPORT BY: Meredith McQuerry, Ph.D Reannan Riedy Brooke Garringer Florida State University © 2018 Fire Protection Research Foundation 1 Batterymarch Park, Quincy, MA 02169-7417, USA Email: [email protected] | Web: nfpa.org/foundation ---page intentionally left blank--- —— Page ii —— FOREWORD There has not been robust validated research conducted on the effects of station wear while worn under a NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting protective ensemble (aka “bunker gear”) in a fire and heat environment. The fire service is generally unaware of the risk that is associated with the use of non-certified NFPA garments, including synthetic fabrics, while worn as station wear garments under bunker gear. The second leading cause of fire fighter injuries in the United States is exposure to heat and smoke. The scope of NFPA 1975, Standard on Emergency Services Work Clothing Elements specifies the requirements for the design, performance, testing, and certification of non-primary protective work apparel and the individual garments comprising work apparel. The standard also specifies the requirements for the thermal stability of textiles used in the construction of work apparel. The project goal is to establish a baseline understanding of burn protection provided by garments worn under bunker gear based on their thermal stability. This project is comprised of the following tasks: • Review the requirements of NFPA 1975 for thermal stability. • Identify available reports, articles, or other documents related to the risks associated with garments while worn as station wear under bunker gear.
    [Show full text]