Ecosmart Mix

Total Page:16

File Type:pdf, Size:1020Kb

Ecosmart Mix ECOSMART MIX Medium Voltage Air Insulated Switchgear for Secondary Distribution A Company Attuned To Your Needs After a century of engineering exceptionally long-lasting electrical distribution and transmission solutions, G&W Electric knows power. And more importantly, we know the power of listening. By taking time to understand your application and ask the right questions, we develop solutions tailored to your needs. The answer may be our time-tested switches that keep power running seamlessly in mission-critical applications, or an advanced automation system for next-generation grids. Whatever your challenge, you’ll experience decades of high performance — and your needs will always be heard. Service continuity, long life performance and personnel safety are paramount. The ECOSMART MIX series is fully developed and type tested according to the IEC standards 62271-200. The quality system complies with ISO 9001-100 standards and it is certified by a third party certification. The health and safety management system complies with the OHSA 18001 standards and is certified by a third party certification. The internal test laboratory complies with UNI CEI EN ISO/IEC 17025 with tests certified by an independent certification body. Sustainability and Environment Care The ECOSMART MIX series development has been driven by environmental sustainability. The materials used for its production allow a low environmental impact during the product life cycle. The ECOSMART MIX production site and the environmental management system is in compliance with the standard quality rules of ISO 14001. General Description The ECOSMART MIX series is composed of air insulated switchgear that offers a loss of service continuity type “LSC2A-PM”, developed in accordance with the following standards: • IEC 62271-200 - High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1kV and up to 52kV • IEC 62271-100 - High-voltage switchgear and controlgear –Part 100: Alternating current circuit breakers • IEC 62271-102 - High-voltage switchgear and controlgear –Part 102: Alternating current disconnectors and earthing switches • IEC 62271-103 - High-voltage switchgear and controlgear –Part 103: Switches for rated voltages above 1kV and up to 52kV • IEC 62271-105 - High-voltage switchgear and controlgear –Part 105: Alternating current switchfuse combinations for rated voltages above 1kV and up to 52kV • IEC 60255 - Measuring relays and protection equipment –Part 1: Common requirements • IEC 60529 - Degrees of protection provided by enclosures (IP Code) ECOSMART MIX 1 Medium Voltage Air Insulated Switchgear for Secondary Distribution Flexibility Modular units are available with different combinations of functionality in order to satisfy the most common electrical configurations of typical substation and distribution circuits. The series brings to the market a versatile switchgear ready to cover a variety of installation requirements and market segments. Each switchboard is composed of a busbar compartment and cable compartment, both air insulated and separated by a 3 position gas insulated switch disconnector. The modularity and compact dimensions of the product allow for a reduced footprint and ease of installation where space is limited. A low voltage control box can be included to contain the low voltage circuits as well as protection and measuring devices. Applications for the ECOSMART MIX series include: • Public medium voltage secondary distribution • Transformers substations • Hospitals • Residential centers • Power transformer protection • Data center protection • Industries • Renewable energy plants ECOSMART MIX List of available functional units ECOSMART MIX 12-24kV TYPOLOGIES DESCRIPTION L Cables riser B Busbar riser (Incoming) BV Busbar riser (Incoming) with VT arrangement BE Busbar riser with earth switch BAV Busbar riser with CT and VT arrangement S Switch disconnector SA Switch disconnector and CT arrangement SAV Switch disconnector and CT/VT arrangement SB-L Switch disconnector and busbar riser left SB-R Switch disconnector and busbar riser right SBM-L Switch disconnector busbar riser left with CT/VT arrangement SBM-R Switch disconnector busbar riser right and CT/VT arrangement FS Switch disconnector and fuses FSL Switch disconnector, fuses, lateral cables outgoing MFS Measure switch disconnector with fuses and VT arrangement CBS Vacuum circuit breaker and disconnector 2 ECOSMART MIX 12-24kV TYPOLOGIES DESCRIPTION CBSB Vacuum circuit breaker, disconnector, busbar riser CBSA Vacuum circuit breaker, disconnector, CT arrangement CBSV Vacuum circuit breaker, disconnector, VT arrangement CBSAV Vacuum circuit breaker, disconnector, CT & VT arrangement CBSAB Vacuum circuit breaker, disconnector, CT arrangement, busbar riser CB2SA Vacuum circuit breaker, double disconnector, CT arrangement CBS-CV Vacuum circuit breaker, Disconnector, CT/VT arrangement (up-side down version) VG Integrated system with vacuum circuit breaker and gas insulated switch disconnector VG-A Integrated system with vacuum circuit breaker; gas insulated switch disconnector with CT VG-AV Integrated system with vacuum circuit breaker; gas insulated switch disconnector with CT/VT VG-AB Integrated system with vacuum circuit breaker; gas insulated switch disconnector with CT, busbar riser Integrated system with vacuum circuit breaker; gas insulated switch disconnector with CT/VT VG-AVB busbar riser MAV Metering with CT/VT, incoming and outgoing from busbar compartment MFAV Metering with CT/VT protected by fuses arrangement, incoming and outgoing from busbar compartment MAVL Metering with CT/VT, incoming from cables compartment and outgoing from busbar compartment MAVD Metering with CT VT, incoming and outgoing from cables compartment Example of functional unit S: Structure and components 1. Busbar Compartment 2. Low Voltage Box 3. Switch disconnector 4. Operating Mechanism 5. Operating lever 1 6. Cable connection 7. Voltage presence device 8. Cable clamps 9. Cable Entry Grommets 2 10. Bottom plate 11. Cable Compartment Door 3 6 4 7 8 5 9 11 10 ECOSMART MIX 3 Medium Voltage Air Insulated Switchgear for Secondary Distribution Additonal functional units: FS, CBS, VG FS Unit CBS Unit VG Unit ECOSMART MIX Features and Benefits The ECOSMART MIX distribution switchgear is characterized by the highest level of technology used by G&W Electric in manufacturing medium voltage equipment. Over 100 years of experience allows G&W Electric to offer a comprehensive range of compact, sealed for life, gas switch disconnectors that are safe and easy to install with limited maintenance. ECOSMART MIX is designed for indoor installation and is compliant with IEC 60529 with the following degrees of protection: • IP 3X - enclosure • IP 2X - enclosure with panel door opened Safety / Reliability • LSC2A-PM class • Complete cubicle earthing through the stainless steel tank, ensuring safe access to the cubicle • Double isolation of the cubicle with switch-disconnector in open position • A complete interlocking system providing safe operating sequences • Anti-reflex function of the operating lever • Switch-disconnector positive position indicator Versatility • Wide range of accessories available • Easy replacement Environment Care • Reduced use of epoxy resin components • Reduced use of gas quantity • Use of recyclable material with easy recovery and reuse at the end of the product life Each cubicle is composed by four main sections: • Busbars compartment • Switch disconnector • Cables compartment • Low voltage compartment ECOSMART MIX 3 4 Medium Voltage Air Insulated Switchgear for Secondary Distribution Integrated System with vacuum circuit breaker & gas insulated disconnector ECOSMART VG is suitable for line and transformer protection applications. It’s composed of a vacuum circuit breaker combined with a three position disconnector, embedded in the same welded stainless steel tank filled with insulated gas. All the operations are performed from the front of the equipment. The vacuum circuit breaker, located upstream the disconnector, is equipped with an operating mechanism, spring stored energy type, with opening and closing operations independent from the operator. The operating mechanism spring can be charged manually, through the lever embedded on the apparatus front, or by the gear motor supplied upon request. Opening and closing operations are carried out with the available push buttons or by means of the opening and closing coils, actuated from remote. The disconnector, connected downstream of the circuit breaker, is a three position type (closed-sectionalised- earthed) and is provided with an operating mechanism exceeding dead center type, having opening and closing speed independent from the operator. The three upper insulators of the apparatus connect the circuit breaker’s contacts to the main busbars system by means of bolts, while the lower insulators allow the connection between the disconnector and the medium voltage cables. The insulators are made of quartz-reinforced epoxy resin. 1700mm 1700mm 750mm 500mm Busbars Compartment The bus bar compartment contains the three phase busbar system to allow the extension with other units on both sides while remaining separated from the other compartments. The busbars are made of copper size 30x8mm, for rated currents up to 630A (upon request the busbars system can be sized for rated current up to 800A or 1250A). The busbars are connected to the switch-disconnectors upper contacts. Switch Disconnector
Recommended publications
  • Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment
    Catalog Siemens Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment siemens.com/recloser R-HG11-339.tif 2 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Contents Contents Page Siemens Vacuum Description 5 Recloser 3AD General 6 Switch unit 7 1 Controller 7SR224 9 Medium-Voltage Equipment Controller 7SC80 14 Catalog HG 11.42 · 2018 Special functions and applications 19 Standards, ambient conditions, altitude correction factor and number of operating cycles 20 Invalid: Catalog HG 11.42 · 2016 Product range overview 21 Scope of delivery 22 siemens.com/recloser Product Selection 25 Ordering data and configuration example 26 Selection of primary ratings 27 2 Selection of controller 30 Selection of additional equipment 34 Selection of accessories and spare parts 35 Additional components for increased performance 37 3EK7 specifications according to IEC 38 3EK8 specifications according to IEEE 39 3EK7 / 3EK8 surge arresters 40 Technical Data 41 Electrical data, dimensions and weights: Voltage level 12 kV 42 3 Voltage level 15.5 kV 42 Voltage level 24 kV 43 Voltage level 27 kV 44 Voltage level 38 kV 45 Dimension drawings 46 Annex 51 Inquiry form 52 Configuration instructions 53 4 Configuration aid Foldout page The products and systems described in this catalog are manufactured and sold according to a certified management system (acc. to ISO 9001, ISO 14001 and BS OHSAS 18001). Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 3 R-HG11-300.tif 4 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Description Contents
    [Show full text]
  • Operation and Earthing of System Equipment
    Operation and Earthing of System Equipment Summary: This document supports the Power System Safety Rules and its requirements assembled under: • Operate HV AIS Switchgear – Category 5.5; • Operate HV GIS Switchgear – Category 5.6; • Issue a Field Access Authority – Category 6.4; and • Operate HV AIS Switchgear for work on or near Overhead Lines – Category 6.5. It applies to the operation and earthing of High Voltage switchgear under the direction of the Controller. Document reference no: GD SR G2 004 Revision no: 3 Date: 7 November 2014 Business function: Operate the Network Document type: Safety Rules Work Instruction Process owner: General Manager/System Operations Author: James Mason, Project Coordinator/Network Services & Operations Reviewers: Don Mckay, Network Controller/System Operations Perry Hall, Network Controller/System Operations Geoff Cook, Manager/Operations Planning Approver: Neil Smith, General Manager/System Operations When referring to TransGrid’s policies, frameworks, procedures or work instructions, please use the latest version published on the intranet. Table of Contents 1. Overview ......................................................................................................................................................... 3 1.1. Purpose ................................................................................................................................................. 3 1.2. Policy Base ...........................................................................................................................................
    [Show full text]
  • Safe Isolation of Main Circuits with Switch-Disconnectors N Or with Molded Case Switches NS
    www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, Technical Paper switching and managing power. In industry, in buildings and in Dipl.-Ing. Wolfgang Esser machine construction. Innovative protection concepts. With built-in diagnostics and communication functions. Housed in modern switchboard systems. Circuit-breaker NZM Circuit-breaker IZM Switchboard systems For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Dipl.-Ing. Wolfgang Esser Head of Industrial Switchgear Product Support Business Unit Circuit-Breakers, Motor Starters and Drives Moeller GmbH, Bonn With grateful acknowledgement of the support from: Mr. Andre R. Fortin BA Phys. Moeller Electric Corporation, Millbury, Massachusetts, USA 2 For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Safe Isolation of Main Circuits with classified – per the newly updated Disconnecting Means, a term that has Switch-Disconnectors N or with IEC / EN 60 947-2, Annex L – to be a become the norm in the meantime. Molded Case Switches NS circuit-breaker without overload release Under certain circumstances and with CBI-X, rather than a switch-disconnector the appropriate identification and - Achieving world market rated switches per IEC / EN 60 947-3. Devices markings, these switches can also in spite of differing demands placed on incorporating short-circuit releases adopt the function of a main supply switches in the IEC world and in North continue to belong exclusively to the Emergency-Stop switch as defined America. - domain reserved for circuit-breakers in under IEC / EN 60 204-1 [1]. most of the world.
    [Show full text]
  • FN Range - Ordering Information
    Performance With Safety Switch-Disconnector-Fuse Type FN ABOUT US Switchgear Factory, Navi Mumbai Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience in this field, the Company today enjoys a leadership position in the Indian market with a growing international presence. It offers a complete range of products including powergear, controlgear, industrial automation, Switchgear Factory, Ahmednagar building electricals & automation, Power Quality Solutions, energy meters, and protective relays. These products conform to Indian and International Standards. Switchgear Factory, Vadodara Content Standards & Approvals 1 All about switches 2 FN Family 5 Product Features 7 Technical Specifications 11 Selection of Handle 13 Ordering Information 14 Spares and Accessories 15 HRC Fuses 16 Characteristic Curves 24 Overall Dimensions 27 Standards & Approvals Switch-Disconnector-Fuse range comply with following standards • IEC 60947-1, EN 60947-1, IS/IEC 60947-1 Low-voltage switchgear and controlgear, Part 1: General Rules • IEC 60947-3, EN 60947-3, IS/IEC 60947-3 Low-voltage switchgear and controlgear, Part 3: Switches, disconnectors, switch-disconnectors and fuse combination units NABL NABL accreditation is a formal recognition of the technical competence of testing, calibration or medical laboratory for a specific task following ISO/IEC 17025:2005 Standard. Accredited laboratories have the responsibility of satisfying the criteria of laboratory accreditation at all times, which are verified during Surveillance and Reassessment visits by NABL.
    [Show full text]
  • Medium-Voltage Switchgear Type 8DA Extendable Fixed-Mounted Circuit-Breaker Switchgear up to 40.5 Kv, Single Busbar, Single-Pole Metal-Enclosed, Gas-Insulated
    Medium-Voltage Switchgear Type 8DA Extendable Fixed-Mounted Circuit-Breaker Switchgear up to 40.5 kV, Single Busbar, Single-Pole Metal-Enclosed, Gas-Insulated Medium-Voltage Switchgear INSTALLATION AND OPERATING INSTRUCTIONS Order No.: 861-9272.9 Revision: 05 Issue: 01-03-2008 About these Instructions These instructions do not purport to cover all details or To connect or install devices from other manufacturers, variations in equipment, nor to provide for every possible the associated user information and ratings have to be contingency to be met in connection with installation or considered. operation. If you want to make suggestions for improvement of Should further information be desired or should these instructions, or if there is something you do not particular problems arise which are not covered understand, please contact the address given below: sufficently by these instructions, the matter should be Energy Sector referred to the competent Siemens department. Siemens AG The contens of this instruction manual shall not become part of or modify any prior or existing agreement, Division Power Distribution commitment or relationship. The Sales Contract Carl-Benz-Str. 22 contains the entire obligations of Siemens. The warranty contained in the contract between the parties is the sole D-60386 Frankfurt warranty of Siemens. Any statements contained herein Germany do not create new warranties or modify the existing warranty. Subject to changes. 2 Revision 05 * INSTALLATION AND OPERATING INSTRUCTIONS 8DA * 861-9272.9 `çåíÉåíë p~ÑÉíó=áåëíêìÅíáçåëKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKR 15.2 Other accessories..............................................32 1 Signal terms and definitions................................ 5 fåëí~ää~íáçå KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK PP 2 General instructions ............................................ 5 16 Before installation ..............................................33 3 Due application...................................................
    [Show full text]
  • Electrical Safety in the Workplace® ARTICLE 90 Introduction
    ARTICLE 90 — INTRODUCTION 90.2 NOTE: The following draft shows how the draft of the proposed 2012 edition of NFPA 70E looks based on NFPA ARTICLE 90 staff’s reading of the Committee Actions contained in the Introduction NFPA 70E Technical Committee Report of the Technical Committees on Electrical Safety in the Workplace (i.e., the Committee Actions in the Report on Proposals). NFPA Staff 90.1 Purpose. The purpose of this standard is to provide a frequently prepare and make available drafts such as this as practical safe working area for employees relative to the an aid to participants in reviewing Technical Committee hazards arising from the use of electricity. Reports. Participants are encouraged to review this Report on Proposals and to raise any issues they believe need reso- 90.2 Scope. lution through the making of appropriate comments. Please (A) Covered. This standard addresses electrical safety re- submit your public comments on the proposals, not on the quirements for employee workplaces that are necessary for draft. As mentioned previously, the draft is only an aid for the practical safeguarding of employees during activities reviewing the document, incorporating the proposals. such as the installation, inspection, operation, maintenance, For further information on NFPA codes and standards and demolition of electric conductors, electric equipment, development rules or on how to participate in the NFPA signaling and communications conductors and equipment, codes and standards development process, check the NFPA and raceways for
    [Show full text]
  • Switch Disconnector and Air Circuit Breaker
    Low voltage Air Circuit Breaker – IZMX Eaton.com SSwitchwitch DDisconnectorisconnector aandnd AAirir CCircuitircuit BBreakerreaker ... with Power Xpert Releases PXR Product Catalog Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power • Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently • Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering businessbusiness worldwide worldwide As a global power management company, we help We provide integrated solutions that help make energy, in customers worldwide manage the power needed for allin allits itsforms, forms, more more practical practical and and accessible. accessible. buildings, aircraft, trucks, cars, machinery and businesses. buildings, aircraft, trucks, cars, machinery and businesses. With 20192014 sales $21.4of $22.6 billion, billion, Eaton Eaton has has approximately approximately Eaton'sEaton’s innovative technologies help customers managemanage 95.000100,000 employees employees around around the the world world and and sells sells products products in electrical, hydraulic and mechanical power more reliably, morein more than than 175 175 countries. countries. effi ciently, safely and sustainably. efficiently, safely and sustainably. Eaton.com Eaton air circuit breakers - for cost-effective, optimized solutions. The IZMX16 is the smallest The IZMX40 is a circuit air circuit-breaker in his class breaker for up to 4000 A in worldwide: a volume of a 3200 A circuit With a volume of only 24 dm3 breaker, without the need to and a front surface of only install any additional “busbar 0.092 m2 it is just slightly extensions” in the connection bigger than the size of a DIN area.
    [Show full text]
  • Best Practice Guide: Electrical Safety and Safe Isolation Procedures
    Best Practice Guide 2 (Issue 3) Guidance on the management of electrical safety and safe isolation procedures for low voltage installations This is one of a series of Best Practice Guides produced by Electrical Safety First* in association with leading industry bodies for the benefit of electrical contractors and installers, and their customers. In electronic format, this Guide is intended to be made available free of Electrical Safety First is indebted to the following charge to all interested parties. Further copies may be downloaded from organisations for their contribution and/or support to the the websites of some of the contributing organisations. development and revision of this Guide, and in particular to The version of this Guide on the Electrical Safety First website SELECT and the HSE for providing the initial draft: (www.electricalsafetyfirst.org.uk) will always be the latest. Feedback on any of the Best Practice Guides is always welcome – email [email protected] BEAMA www.beama.org.uk Electrical Safety First is supported by all sectors of the electrical industry, approvals and research bodies, consumer interest organisations, the BSI electrical distribution industry, professional institutes and institutions, www.bsigroup.com regulatory bodies, trade and industry associations and federations, trade unions, and local and central government. Certsure www.certsure.com *Electrical Safety First (formerly the National Inspection Council for Electrical Installation Contracting) is a charitable non-profit making City
    [Show full text]
  • Ground Lead Disconnectors on Distribution-Class Surge Arresters
    01.4TB.017 Ground Lead Disconnectors on Distribution-Class Surge Arresters July 18, 1991 Many current models of zinc oxide distribution or riser pole arresters come equipped with ground lead disconnectors. This is a device which is mounted on the ground end of the arrester and which looks about like a small hockey puck. The enclosure is black, blue or green plastic, a couple of inches in diameter and an inch or so tall. The normal failure mode of these arresters is a short circuit to ground, causing ground fault current to flow. This current will cause the arrester body to fail if it is not stopped quickly. The first function of the ground lead disconnector is to disconnect the ground lead of the surge arrester in case of an internal failure of the arrester, preventing explosive failure of the arrester body. The ground lead disconnector contains a cartridge in series with a gap. The gap is shunted by a resistor. As the current rises, the voltage across the gap increases until the gap flashes over, creating an arc which ignites the cartridge, blowing the ground lead free. The ground lead disconnector is not a fault current interrupter. The arc drawn by the ground lead as it separates from the body of the arrester may or may not go out on its own. If it does not go out, a circuit breaker, recloser or fuse must operate to extinguish the arc. The ground lead disconnector is expected to create a gap which will not reignite when power is reapplied to the circuit, but the gap which will be created is a function of the length and flexibility of the ground lead.
    [Show full text]
  • Control of Hazardous Energy
    EHS PROGRAM: EHS01P Publish Date: 06/06/2019 Rev: #0 CONTROL OF HAZARDOUS ENERGY Table of Contents Table of Contents .......................................................................................................................................... 1 1. SCOPE and APPLICATION ...................................................................................................................... 2 2. ROLES and RESPONSIBILITIES ................................................................................................................ 2 3. REQUIREMENTS .................................................................................................................................... 4 3.1. Overview: ...................................................................................................................................... 4 3.2. Hazard Assessment: ...................................................................................................................... 5 3.3. Hazardous Energy Controls ........................................................................................................... 5 3.4. Lockout Procedure ........................................................................................................................ 8 3.4. Troubleshooting of Equipment- .................................................................................................... 9 3.5. Periodic Inspections ...................................................................................................................
    [Show full text]
  • — Outdoor Switching Points Catalogue 2 OUTDOOR SWITCHING POINTS OUTDOOR SWITCHING POINTS CATALOGUE 3
    — MEDIUM VOLTAGE PRODUCTS Outdoor switching points Catalogue — Outdoor switching points Catalogue 2 OUTDOOR SWITCHING POINTS OUTDOOR SWITCHING POINTS CATALOGUE 3 — Table of contents 4 – 14 1. Introduction 4 11.1. Feeder automation drivers 4 – 5 1.2. Reliability indexes of energy supply 5 1.3. Zone concept in grid automation 6 1.4. Benefits of zone concept 6 – 7 1.5. Automation concepts for distribution network 7 1.6. Automatic sectionalizer based on voltage signal 8 1.7. Automatic sectionalizer based on fault current detection 9 1.8. Automatic sectionalizer based on fault current detection and voltage signal 10 1.9. Sectionalization with DMS 11 1.10. Sectionalization with DMS and ring network 12 1.11. Switching point - main modules 13 – 14 1.12. Automation levels 15 – 16 2. Sectos pole mounted SF6 load break switch 16 2.1. Basic configurations 17 3. Manual drives 18 – 22 4. Motor drives and control cabinets 18 4.1. Motor drive accessible from ground level UEMC50 19 4.2. Motor drive integrated with switch disconnector UEMC40K8 and control cabinet UEMC-A 20 4.3. Communication modules 21 4.4. Monitoring and remote control (level 2) 22 4.5. Monitoring, control and fault detection (level 3) 23 5. Current measurement 23 5.1. Current transformers KOKU 23 5.2. Voltage sensors 24 6. Supply voltage transformer VOL 25 7. Surge arresters POLIM 26 8. Supporting structures 27 9. Switching point accessories 28 10. Selection form 29 11. Configuration's example 4 OUTDOOR SWITCHING POINTS — Introduction 1.1. Feeder automation drivers 1.1.4 Improvement of safety for the utility In modern energy distribution there are few main personnel factors which drives network automation: The biggest asset of every company are people.
    [Show full text]
  • Consultation on the Implementation of Engineering Recommendation Er G77
    CONSULTATION ON THE IMPLEMENTATION OF ENGINEERING RECOMMENDATION ER G77 VOLUME I: SUMMARY REPORT ETSU S/P2/00356/REP/1 DTI/Pub URN 02/809 Contractor Halcrow Group Ltd Subcontractors SunDog Energy Ltd EA Technology Ltd I-Power Ltd Prepared by J Thornycroft M Cotterell A Collinson The work described in this report was carried out under contract as part of the DTI Sustainable Energy Programmes. The views and judgements expressed in this report are those of the contractor and do not necessarily reflect those of the DTI. First published 2002 © Crown copyright 2002 EXECUTIVE SUMMARY This report presents the results of continued consultation within the Electricity Industry and PV Industry leading to the publication of Engineering Recommendation ER G77/1: ‘Connection of Single-phase Inverter Connected Photovoltaic (PV) Generating Equipment of up to 5kVA in Parallel with a Distribution Network Operators (DNOs) Distribution System ’. It also incorporates a specific piece of technical work carried out under a Subproject ETSU/S/P2/00400. The final subgroup report on that work is reproduced in Volume II. OBJECTIVES This project continues the objectives of a previous ETSU project ETSU/S/P2/00215 that set-up the ‘ER G77 Working Group’ as part of the initiative to: • Continue consultation with the DNOs principally through the ER G77 Group • Continue consultation in the PV Industry through PV-UK membership • Monitor and include experience from the implementation of ER G77 • Act as a forum for discussion of issues arising and recommended improvements to ER G77 • Provide a source of expertise and consultation on PV electrical matters for projects such as the DTI supported Domestic Field Trial • Provide a link to BSI Standards Work in the field • Define and provide a link to Subprojects investigating specific technical questions related to ER G77 The aim has been to help develop the final version of ER G77/1 that is acceptable to the PV industry and electricity supply industry.
    [Show full text]