Guide to the Installation of PV Systems 2Nd Edition
Total Page:16
File Type:pdf, Size:1020Kb

Load more
Recommended publications
-
Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment
Catalog Siemens Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment siemens.com/recloser R-HG11-339.tif 2 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Contents Contents Page Siemens Vacuum Description 5 Recloser 3AD General 6 Switch unit 7 1 Controller 7SR224 9 Medium-Voltage Equipment Controller 7SC80 14 Catalog HG 11.42 · 2018 Special functions and applications 19 Standards, ambient conditions, altitude correction factor and number of operating cycles 20 Invalid: Catalog HG 11.42 · 2016 Product range overview 21 Scope of delivery 22 siemens.com/recloser Product Selection 25 Ordering data and configuration example 26 Selection of primary ratings 27 2 Selection of controller 30 Selection of additional equipment 34 Selection of accessories and spare parts 35 Additional components for increased performance 37 3EK7 specifications according to IEC 38 3EK8 specifications according to IEEE 39 3EK7 / 3EK8 surge arresters 40 Technical Data 41 Electrical data, dimensions and weights: Voltage level 12 kV 42 3 Voltage level 15.5 kV 42 Voltage level 24 kV 43 Voltage level 27 kV 44 Voltage level 38 kV 45 Dimension drawings 46 Annex 51 Inquiry form 52 Configuration instructions 53 4 Configuration aid Foldout page The products and systems described in this catalog are manufactured and sold according to a certified management system (acc. to ISO 9001, ISO 14001 and BS OHSAS 18001). Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 3 R-HG11-300.tif 4 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Description Contents -
Best Practice Guide to Cable Ladder and Cable Tray Systems
Best Practice Guide to Cable Ladder and Cable Tray Systems Channel Support Systems and other Associated Supports November 2012 BEAMA Best Practice Guide to Cable Ladder and Cable Tray Systems Including Channel Support Systems and other Associated Supports Companies involved in the preparation of this Guide Contents INTRODUCTION 5 DEFINITIONS AND ABBREVIATIONS 6 1. Packing Handling and Storage 8 1.1 General Packing and Handling 8 1.2 Loading and offloading recommendations 9 1.3 Storage 11 2A. Installation of the system 12 2.1 Common tools for Installation 12 2.2 Structural characteristics 12 2.3 Support Systems 18 2.4 Straight cable ladder and cable tray lengths 29 2.5 Coupler types (refer to manufacturer’s literature) 32 2.6 Fixings 36 2.7 Fittings 36 2.8 Accessories 39 2.9 Site modification 39 2.10 Earth protection and EMC 40 2B. Installation of Cable 41 2.11 Preparation 41 2.12 Wiring Regulations 41 2.13 Power Cables 41 2.14 Data Cables 46 2.15 Expansion 46 2.16 Electro Mechanical Effects 46 3. Environment 48 3.1 Selecting the right material and finish 48 3.2 Finishes 56 3.3 Non-Metallic systems 61 3.4 Loadings 63 3.5 Temperature 65 4. Health & Safety 67 5. Maintenance 68 5.1 Inspection 68 5.2 Removal of cables 68 5.3 On site repairs 68 6. Sustainability 69 6.1 Sustainable development 69 6.2 REACH regulations 69 6.3 The management of WEEE and RoHS 69 6.4 Environmental footprint 70 7. Applicable Standards 71 Companies involved in the preparation of this Guide 72 FIGURES Figure 1: Methods of removal 9 Figure 2: Loaded beams 13 Figure -
Operation and Earthing of System Equipment
Operation and Earthing of System Equipment Summary: This document supports the Power System Safety Rules and its requirements assembled under: • Operate HV AIS Switchgear – Category 5.5; • Operate HV GIS Switchgear – Category 5.6; • Issue a Field Access Authority – Category 6.4; and • Operate HV AIS Switchgear for work on or near Overhead Lines – Category 6.5. It applies to the operation and earthing of High Voltage switchgear under the direction of the Controller. Document reference no: GD SR G2 004 Revision no: 3 Date: 7 November 2014 Business function: Operate the Network Document type: Safety Rules Work Instruction Process owner: General Manager/System Operations Author: James Mason, Project Coordinator/Network Services & Operations Reviewers: Don Mckay, Network Controller/System Operations Perry Hall, Network Controller/System Operations Geoff Cook, Manager/Operations Planning Approver: Neil Smith, General Manager/System Operations When referring to TransGrid’s policies, frameworks, procedures or work instructions, please use the latest version published on the intranet. Table of Contents 1. Overview ......................................................................................................................................................... 3 1.1. Purpose ................................................................................................................................................. 3 1.2. Policy Base ........................................................................................................................................... -
Safe Isolation of Main Circuits with Switch-Disconnectors N Or with Molded Case Switches NS
www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, Technical Paper switching and managing power. In industry, in buildings and in Dipl.-Ing. Wolfgang Esser machine construction. Innovative protection concepts. With built-in diagnostics and communication functions. Housed in modern switchboard systems. Circuit-breaker NZM Circuit-breaker IZM Switchboard systems For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Dipl.-Ing. Wolfgang Esser Head of Industrial Switchgear Product Support Business Unit Circuit-Breakers, Motor Starters and Drives Moeller GmbH, Bonn With grateful acknowledgement of the support from: Mr. Andre R. Fortin BA Phys. Moeller Electric Corporation, Millbury, Massachusetts, USA 2 For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Safe Isolation of Main Circuits with classified – per the newly updated Disconnecting Means, a term that has Switch-Disconnectors N or with IEC / EN 60 947-2, Annex L – to be a become the norm in the meantime. Molded Case Switches NS circuit-breaker without overload release Under certain circumstances and with CBI-X, rather than a switch-disconnector the appropriate identification and - Achieving world market rated switches per IEC / EN 60 947-3. Devices markings, these switches can also in spite of differing demands placed on incorporating short-circuit releases adopt the function of a main supply switches in the IEC world and in North continue to belong exclusively to the Emergency-Stop switch as defined America. - domain reserved for circuit-breakers in under IEC / EN 60 204-1 [1]. most of the world. -
Answer the Purpose: 4
Page 26 1. CONDUCTORS Conductors are defined as materials that easily allow the flow of _________. Metals are _______ conductors while insulators are ______ . The 2 common metals used for conductors in the electrical trade are: ___________ and ______________. Aluminium has become more prevalent for larger C.S.A. conductors as it is cheaper and lighter but more brittle than copper. Current/ Copper/ Aluminium Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. In mainland Europe, a round equivalent is more common. Flat cables (or festoon cables) are made in PVC and Neoprene and are used as trailing cables for cranes, open filed conveyors and shelve service devices. Flat cables offer the advantages of extremely small bending radius’s, high flexibility and minimum wastage of space. Thermoplastic-sheathed cable (TPS) consists of an outer toughened sheath of polyvinyl chloride (PVC) (the thermoplastic element) covering one or more individual cables which are PVC insulated annealed copper conductors. It is a commonly used type of wiring for residential and light commercial construction in many countries. The flat version of the cable with two insulated conductors and an uninsulated earth conductor all within the outer sheath is referred to as twin and earth. -
BICC Industrial Cables Catalog
TECHNICAL INFORMATION Click here for Table of Contents 9. Technical Information Click the BICC logo above to return to the Section Index TECHNICAL INFORMATION 9.i BICC Cables has made every effort to ensure the accuracy of the information provided in this catalog, however, we cannot be responsible for errors, omissions, or changes due to obsolescence. All data herein is subject to change without notice. Data and suggestions made in this catalog are not to be construed as recommendations to use any product in violation of any government law or regulations relating to any material or its use. EFFECTIVE 1998-09-30 TABLE OF CONTENTS 9. Technical Information Glossary..........................................................................................9.01-9.07 Reference Standards........................................................................9.08-9.16 Cable Handling and Storage ...........................................................9.17-9.20 Cable Pre-Installation..............................................................................9.21 Cable Installation............................................................................9.22-9.28 Cable Testing ..................................................................................9.29-9.32 Common Color Sequence........................................................................9.33 Metric Conversion ..................................................................................9.34 Copper Short Circuit Currents................................................................9.35 -
FN Range - Ordering Information
Performance With Safety Switch-Disconnector-Fuse Type FN ABOUT US Switchgear Factory, Navi Mumbai Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience in this field, the Company today enjoys a leadership position in the Indian market with a growing international presence. It offers a complete range of products including powergear, controlgear, industrial automation, Switchgear Factory, Ahmednagar building electricals & automation, Power Quality Solutions, energy meters, and protective relays. These products conform to Indian and International Standards. Switchgear Factory, Vadodara Content Standards & Approvals 1 All about switches 2 FN Family 5 Product Features 7 Technical Specifications 11 Selection of Handle 13 Ordering Information 14 Spares and Accessories 15 HRC Fuses 16 Characteristic Curves 24 Overall Dimensions 27 Standards & Approvals Switch-Disconnector-Fuse range comply with following standards • IEC 60947-1, EN 60947-1, IS/IEC 60947-1 Low-voltage switchgear and controlgear, Part 1: General Rules • IEC 60947-3, EN 60947-3, IS/IEC 60947-3 Low-voltage switchgear and controlgear, Part 3: Switches, disconnectors, switch-disconnectors and fuse combination units NABL NABL accreditation is a formal recognition of the technical competence of testing, calibration or medical laboratory for a specific task following ISO/IEC 17025:2005 Standard. Accredited laboratories have the responsibility of satisfying the criteria of laboratory accreditation at all times, which are verified during Surveillance and Reassessment visits by NABL. -
Electric Cooktop Installation Instructions
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. IMPORTANT INSTALLATION INFORMATION • All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only electrical supply with ground. • Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm). For Standard Installation: * 30" (76.2 cm) min. for unprotected cabinet 24" (61 cm) min. for protected surface 30" Min. * (76.2 cm) B Cooktop Dimensions A C 4"X 8" (10.2 cm x 20.3 cm) opening to route armoured cable. Cooktop Cutout Dimensions 7¼" (18.4 cm) H*** E F D G 1" (2.5 cm) 35 1/8" (89.2 cm) **Note: D & E are critical to the proper installation of the cooktop. Please make sure to respect those Do not slide unit into cabinet cutout. dimensions. D reflects a finished dimension it is Protruding screws on the bottom of recommended to undercut this dimension and unit may damage the bottom front adjust upon installation of the appliance due to the finish. Figure 1 variation in countertop materials. CUTOUT DIMENSIONS H. DEPTH BELOW MODEL A. LENGTH B. WIDTH C. DEPTH LENGTH WIDTH COOKTOP*** D** E** FG 7 15 3 1 1 36 (91.4 ) 35 /8 (91.1) 25¾ (65.4) 7¾ (19.7) 35 /16 (91.3) 35 /16 (89.4) 22 (55.9) 1 /8 (2.9) Max. -
Medium-Voltage Switchgear Type 8DA Extendable Fixed-Mounted Circuit-Breaker Switchgear up to 40.5 Kv, Single Busbar, Single-Pole Metal-Enclosed, Gas-Insulated
Medium-Voltage Switchgear Type 8DA Extendable Fixed-Mounted Circuit-Breaker Switchgear up to 40.5 kV, Single Busbar, Single-Pole Metal-Enclosed, Gas-Insulated Medium-Voltage Switchgear INSTALLATION AND OPERATING INSTRUCTIONS Order No.: 861-9272.9 Revision: 05 Issue: 01-03-2008 About these Instructions These instructions do not purport to cover all details or To connect or install devices from other manufacturers, variations in equipment, nor to provide for every possible the associated user information and ratings have to be contingency to be met in connection with installation or considered. operation. If you want to make suggestions for improvement of Should further information be desired or should these instructions, or if there is something you do not particular problems arise which are not covered understand, please contact the address given below: sufficently by these instructions, the matter should be Energy Sector referred to the competent Siemens department. Siemens AG The contens of this instruction manual shall not become part of or modify any prior or existing agreement, Division Power Distribution commitment or relationship. The Sales Contract Carl-Benz-Str. 22 contains the entire obligations of Siemens. The warranty contained in the contract between the parties is the sole D-60386 Frankfurt warranty of Siemens. Any statements contained herein Germany do not create new warranties or modify the existing warranty. Subject to changes. 2 Revision 05 * INSTALLATION AND OPERATING INSTRUCTIONS 8DA * 861-9272.9 `çåíÉåíë p~ÑÉíó=áåëíêìÅíáçåëKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKR 15.2 Other accessories..............................................32 1 Signal terms and definitions................................ 5 fåëí~ää~íáçå KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK PP 2 General instructions ............................................ 5 16 Before installation ..............................................33 3 Due application................................................... -
Electrical Safety in the Workplace® ARTICLE 90 Introduction
ARTICLE 90 — INTRODUCTION 90.2 NOTE: The following draft shows how the draft of the proposed 2012 edition of NFPA 70E looks based on NFPA ARTICLE 90 staff’s reading of the Committee Actions contained in the Introduction NFPA 70E Technical Committee Report of the Technical Committees on Electrical Safety in the Workplace (i.e., the Committee Actions in the Report on Proposals). NFPA Staff 90.1 Purpose. The purpose of this standard is to provide a frequently prepare and make available drafts such as this as practical safe working area for employees relative to the an aid to participants in reviewing Technical Committee hazards arising from the use of electricity. Reports. Participants are encouraged to review this Report on Proposals and to raise any issues they believe need reso- 90.2 Scope. lution through the making of appropriate comments. Please (A) Covered. This standard addresses electrical safety re- submit your public comments on the proposals, not on the quirements for employee workplaces that are necessary for draft. As mentioned previously, the draft is only an aid for the practical safeguarding of employees during activities reviewing the document, incorporating the proposals. such as the installation, inspection, operation, maintenance, For further information on NFPA codes and standards and demolition of electric conductors, electric equipment, development rules or on how to participate in the NFPA signaling and communications conductors and equipment, codes and standards development process, check the NFPA and raceways for -
Switch Disconnector and Air Circuit Breaker
Low voltage Air Circuit Breaker – IZMX Eaton.com SSwitchwitch DDisconnectorisconnector aandnd AAirir CCircuitircuit BBreakerreaker ... with Power Xpert Releases PXR Product Catalog Energizing a world that demands more. We deliver: • Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable • Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power • Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently • Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today’s Eaton. Powering businessbusiness worldwide worldwide As a global power management company, we help We provide integrated solutions that help make energy, in customers worldwide manage the power needed for allin allits itsforms, forms, more more practical practical and and accessible. accessible. buildings, aircraft, trucks, cars, machinery and businesses. buildings, aircraft, trucks, cars, machinery and businesses. With 20192014 sales $21.4of $22.6 billion, billion, Eaton Eaton has has approximately approximately Eaton'sEaton’s innovative technologies help customers managemanage 95.000100,000 employees employees around around the the world world and and sells sells products products in electrical, hydraulic and mechanical power more reliably, morein more than than 175 175 countries. countries. effi ciently, safely and sustainably. efficiently, safely and sustainably. Eaton.com Eaton air circuit breakers - for cost-effective, optimized solutions. The IZMX16 is the smallest The IZMX40 is a circuit air circuit-breaker in his class breaker for up to 4000 A in worldwide: a volume of a 3200 A circuit With a volume of only 24 dm3 breaker, without the need to and a front surface of only install any additional “busbar 0.092 m2 it is just slightly extensions” in the connection bigger than the size of a DIN area. -
Best Practice Guide: Electrical Safety and Safe Isolation Procedures
Best Practice Guide 2 (Issue 3) Guidance on the management of electrical safety and safe isolation procedures for low voltage installations This is one of a series of Best Practice Guides produced by Electrical Safety First* in association with leading industry bodies for the benefit of electrical contractors and installers, and their customers. In electronic format, this Guide is intended to be made available free of Electrical Safety First is indebted to the following charge to all interested parties. Further copies may be downloaded from organisations for their contribution and/or support to the the websites of some of the contributing organisations. development and revision of this Guide, and in particular to The version of this Guide on the Electrical Safety First website SELECT and the HSE for providing the initial draft: (www.electricalsafetyfirst.org.uk) will always be the latest. Feedback on any of the Best Practice Guides is always welcome – email [email protected] BEAMA www.beama.org.uk Electrical Safety First is supported by all sectors of the electrical industry, approvals and research bodies, consumer interest organisations, the BSI electrical distribution industry, professional institutes and institutions, www.bsigroup.com regulatory bodies, trade and industry associations and federations, trade unions, and local and central government. Certsure www.certsure.com *Electrical Safety First (formerly the National Inspection Council for Electrical Installation Contracting) is a charitable non-profit making City