Another Approach to Electrical Protection Fuse Solutions from the World Leader in Electrical Protection

Total Page:16

File Type:pdf, Size:1020Kb

Another Approach to Electrical Protection Fuse Solutions from the World Leader in Electrical Protection Fuse device offer Another approach to electrical protection Fuse solutions from the world leader in electrical protection As world leader in electrical distribution and protection, Schneider Electric proposes a fuse device offer that is one of the most flexible and comprehensive on the market. Essential functions combined with advanced features such as measurement and remote control, make the Schneider Electric fuse device offer The most a "best in class" solution to guarantee electrical protection of industrial complete fuse applications. device offer in single and double The essentials of electrical protection breaking: switch disconnector Schneider Electric fuse devices represent a comprehensive and optimized offer, designed to perform the 3 essential functions of electrical protection: fuses, fuse switch 1- Switch function for circuit on-load control disconnectors, 2- Fuse function against short-circuits and overloads and disconnector 3- Isolation from the power circuit fuses. Double breaking offer: Switch disconnector fuses Functions: TeSys GS > Short-circuit and overload protection 32 to 1250 A > Isolation > On-load switching of circuits > High level of safety thanks to the upstream and downstream double breaking > Fast opening and closing > Opening and closing operations are independent of the operator’s action Fupact ISFL Fupact INF 160 to 630 A 32 to 800 A 2 Schneider Electric fuse device offer: another way to meet your electrical protection requirements The Schneider Electric fuse device offer gives you maximum safety, high performance and compliance with international standards and certifications. Complete Simple and Designed Fully Fully Schneider flexible for safety compatible certified Engineered to ensure Electric > Easy to choose Schneider Electric The Schneider Electric safety of persons solution thanks to an optimized fuse solutions have fuse offer complies and equipment: Fuse solutions offering catalogue been designed with international interlocking to prevent a perfect integration > Easy to install for use with all standards and access to fuses when into Schneider Smart features, fuse-links complying certifications for the switch is on the Electric functional flexibility in terms with switchgear switchgear: closed position, standards: and universal of current footprint, > IEC 60947-1 and -3 double isolation, electrical enclosures: cable connections, > BS 88-1/8-4 testing of auxiliaries > EN 60947-1 and -3 Prisma Plus, Prisma product position, etc. > DIN 43620 possible with no > IEC 60269 IPM, Canalis, etc. > Easy to use > NFEN 60269- need to close main > EN 60269-1 and -4 Standard operating Schneider Electric contacts, high IP 1/60269-4 process and simple > CCC certificates offers complete level, etc. > NFC 63 220 electrical protection maintenance. and distribution systems including fuse devices. Single breaking offer: Disconnector Fuse switch disconnectors fuse Functions: Function: > Short-circuit and overload protection TeSys DF* > Short-circuit and > Isolation 25 to 125 A overload protection > On-load switching of circuits Fupact ISFT 100 to 630 A > High level of reliability against short-circuits > High level of reliability > High flexibility on busbar systems against short-circuits > Opening and closing operations are > Modular design for DIN dependent on the operator’s action rail installation > Compact size *For further information see brochure DIA1ED1061201, available on www.schneider-electric.com 3 Double breaking fuse solutions: Fupact INF and TeSys GS switch disconnector fuses Power control centre applications: Ensure your power distribution with Fupact INF Fupact INF switch disconnector fuses are: Motor control centre applications: > Distribution switchboards. Power and control your industrial > Disconnection, isolation, locking and motors with TeSys GS primary control of incoming circuits. > Categories AC21/AC22 for electrical TeSys GS switch disconnector fuses distribution, AC23 for motor feeders. are designed for applications such as: > Safety or emergency stop. > Motor starters: DOL, Star-Delta, softstarters (switch fuse for isolation and short-circuit protection). Electrical > Variable speed starters with frequency distribution converters. > Machine types: HVAC units, industrial cranes, hoists. > Industries: paper, steel, ports, automotive, power, mining, rail, oil & gas. > Safety or emergency stop. Machines Industry 4 Double breaking fuse solutions: Double breaking Fupact INF and TeSys GS switch disconnector fuses Designed for a high level of safety Maximum Flexible Compact Combine safety solution design efficiency and intelligent > Interlocking to > Compatible with > Very small footprint control thanks to prevent access when all fuse standards: and compact the switch is closed. BS, DIN and NFC. volume, especially the fuse monitor > Double isolation, > Adapted to for Fupact INF. Available for the upstream and all electrical > No extra space Fupact INF range, the downstream when installations, needed for auxiliary fuse monitor is more the switch is open. even for highly contacts. When than an accessory. > Auxiliary circuit unbalanced mounted, their Its protection and testing. conditions. volume is included monitoring functions in the device's make the fuse monitor > IP20 snap-on standard footprint. almost indispensable: shrouding. > Reliable position > A common indicators. monitoring solution for the complete range. > Automatic reset of the fuse monitor after replacement of a blown fuse. > Auxiliary contacts for different functions: alarm, tripping of a remote device, etc. > No need for striker- type fuses, leading to a significant cost reduction. 5 Single breaking fuse solutions: Fupact ISFL and Fupact ISFT fuse switch disconnectors Fupact ISFL fuse switches > Main power distribution switchboards. > Public power distribution for Power Fupact ISFT fuse switches Supply Companies. > Categories AC21/ > Power distribution: secondary distribution AC22 for electrical circuits (AC21 / AC22 categories). distribution, AC23 for > Powering and control of industrial motors motor feeders. as local isolation device (AC23 category). Electrical distribution Industry 6 Single breaking fuse solutions: Single breaking Fupact ISFL and Fupact ISFT fuse switch disconnectors Simplicity and flexibility for your busbar applications Flexibility Intelligent Simplicity Combine > Adapted to all control and > Easily hooked. efficiency busbar systems: measurement > Turnable contact and intelligent Fupact ISFL: hooks available for control with 60/100/185 mm, > Precise location and Fupact ISFL. present in main the Fupact ISFL fast correction of > Fast mounting with switchboards; short-circuit and reduced manual and Fupact ISFT Fupact ISFT: overload faults thanks operations. ranges as well 60/100 mm, to the fuse monitor. present in secondary > Easy and user- > A common > For Fupact ISFL, switchboards. friendly installation. monitoring solution energy consumption for Fupact ISFL range > Also compatible control is feasible by and for with installation on the easy installation of Fupact ISFT range. mounting plate. the new measuring > High flexibility in cable bracket. > Automatic reset of the fuse monitor after connections. > For Fupact ISFL, replacement of a Additionally, for Fupact standardized blown fuse. ISFL, new terminal interfaces for all types box allowing cable lug of measurement > Auxiliary contacts for or direct connections. devices. different functions: > For Fupact ISFL, no alarm, tripping of a extra space needed remote device, etc. for current transformer installation. > No need for striker- type fuses, leading to a significant cost reduction. 7 No matter your application, Schneider Electric provides you with complete electrical distribution and protection solutions combining fuse devices and circuit breakers to perfectly match your needs for reliability, efficiency and performance. Benefit from the best of Schneider Electric Like all Schneider Electric offers, fuse solutions benefit from the experience and the worldwide organization of Schneider Electric: > Leadership in electrical protection and power control; > Guaranteed product availability; > The broadest technical and after sales support; > Solutions which are "Tested, Validated and Documented" (TVD). Make the most of your energy www.schneider-electric.com Schneider Electric Industries SAS 35, rue Joseph Monier As standards, specifications and designs change from time to time, please ask for confirmation CS 30323 of the information given in this publication. F- 92506 Rueil Malmaison Cedex Printed on ecological paper RCS Nanterre 954 503 439 Capital social 896 313 776 Publication: Schneider Electric www.schneider-electric.com Design-Layout: SEDOC Photo : © Monty Rakusen / GraphicObsession Printing: Altavia Connexion - Made in France EDCED110003EN 05-2011 960567 © 2011- Schneider Electric - All rights reserved. ART..
Recommended publications
  • Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment
    Catalog Siemens Vacuum Recloser 3AD HG 11.42 · Edition 2018 Medium-Voltage Equipment siemens.com/recloser R-HG11-339.tif 2 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Contents Contents Page Siemens Vacuum Description 5 Recloser 3AD General 6 Switch unit 7 1 Controller 7SR224 9 Medium-Voltage Equipment Controller 7SC80 14 Catalog HG 11.42 · 2018 Special functions and applications 19 Standards, ambient conditions, altitude correction factor and number of operating cycles 20 Invalid: Catalog HG 11.42 · 2016 Product range overview 21 Scope of delivery 22 siemens.com/recloser Product Selection 25 Ordering data and configuration example 26 Selection of primary ratings 27 2 Selection of controller 30 Selection of additional equipment 34 Selection of accessories and spare parts 35 Additional components for increased performance 37 3EK7 specifications according to IEC 38 3EK8 specifications according to IEEE 39 3EK7 / 3EK8 surge arresters 40 Technical Data 41 Electrical data, dimensions and weights: Voltage level 12 kV 42 3 Voltage level 15.5 kV 42 Voltage level 24 kV 43 Voltage level 27 kV 44 Voltage level 38 kV 45 Dimension drawings 46 Annex 51 Inquiry form 52 Configuration instructions 53 4 Configuration aid Foldout page The products and systems described in this catalog are manufactured and sold according to a certified management system (acc. to ISO 9001, ISO 14001 and BS OHSAS 18001). Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 3 R-HG11-300.tif 4 Siemens Vacuum Recloser 3AD · Siemens HG 11.42 · 2018 Description Contents
    [Show full text]
  • Switched-Capacitor Circuits
    Switched-Capacitor Circuits David Johns and Ken Martin University of Toronto ([email protected]) ([email protected]) University of Toronto 1 of 60 © D. Johns, K. Martin, 1997 Basic Building Blocks Opamps • Ideal opamps usually assumed. • Important non-idealities — dc gain: sets the accuracy of charge transfer, hence, transfer-function accuracy. — unity-gain freq, phase margin & slew-rate: sets the max clocking frequency. A general rule is that unity-gain freq should be 5 times (or more) higher than the clock-freq. — dc offset: Can create dc offset at output. Circuit techniques to combat this which also reduce 1/f noise. University of Toronto 2 of 60 © D. Johns, K. Martin, 1997 Basic Building Blocks Double-Poly Capacitors metal C1 metal poly1 Cp1 thin oxide bottom plate C1 poly2 Cp2 thick oxide C p1 Cp2 (substrate - ac ground) cross-section view equivalent circuit • Substantial parasitics with large bottom plate capacitance (20 percent of C1) • Also, metal-metal capacitors are used but have even larger parasitic capacitances. University of Toronto 3 of 60 © D. Johns, K. Martin, 1997 Basic Building Blocks Switches I I Symbol n-channel v1 v2 v1 v2 I transmission I I gate v1 v p-channel v 2 1 v2 I • Mosfet switches are good switches. — off-resistance near G: range — on-resistance in 100: to 5k: range (depends on transistor sizing) • However, have non-linear parasitic capacitances. University of Toronto 4 of 60 © D. Johns, K. Martin, 1997 Basic Building Blocks Non-Overlapping Clocks I1 T Von I I1 Voff n – 2 n – 1 n n + 1 tTe delay 1 I fs { --- delay V 2 T on I Voff 2 n – 32e n – 12e n + 12e tTe • Non-overlapping clocks — both clocks are never on at same time • Needed to ensure charge is not inadvertently lost.
    [Show full text]
  • Switched Capacitor Concepts & Circuits
    Switched Capacitor Concepts & Circuits Outline • Why Switched Capacitor circuits? – Historical Perspective – Basic Building Blocks • Switched Capacitors as Resistors • Switched Capacitor Integrators – Discrete time & charge transfer concepts – Parasitic insensitive circuits • Signal Flow Graphs • Switched Capacitor Filters – Comparison to Active RC filters – Advantages of Fully Differential filters • Switched Capacitor Gain Circuits • Reducing the Effects of Charge Injection • Tradeoff between Speed and Charge Injection Why Switched Capacitor Circuits? • Historical Perspective – As MOS processes came to the forefront in the late 1970s and early 1980s, the advantages of integrating analog blocks such as active filters on the same chip with digital logic became a driving force for inovation. – Integrating active filters using resistors and capacitors to acturately set time constants has always been difficult, because of large process variations (> +/- 30%) and the fact that resistors and capacitors don’t naturally match each other. – So, analog engineers turned to the building blocks native to MOS processes to build their circuits, switches & capacitors. Since time constants can be set by the ratio of capacitors, very accurate filter responses became possible using switched capacitor techniques Æ Mixed-Signal Design was born! Switched Capacitor Building Blocks • Capacitors: poly-poly, MiM, metal sandwich & finger caps • Switches: NMOS, PMOS, T-gate • Op Amps: at first all NMOS designs, now CMOS Non-Overlapping Clocks • Non-overlapping clocks are used to insure that one set of switches turns off before the next set turns on, so that charge only flows where intended. (“break before make”) • Note the notation used to indicate time based on clock periods: ... (n-1)T, (n-½)T, nT, (n+½)T, (n+1)T ..
    [Show full text]
  • Printed Circuit Board Mount Switches Shock Proof • Waterproof • Explosion
    shock proof • waterproof • explosion proof Printed Circuit Board Mount Switches These versatile switches are a great choice for many applications due to their small size and variety of connection styles. Although these switches are built to connect to a printed circuit board, they can also be retrotted for nearly any application by connecting wire leads. These switches can sense a pressure ranging from 6 inches of water all the way up to 65 PSI. For a frame of reference, a trumpet player blows 55 inches of water (or 2 PSI) on average, so these switches have a broad range. They can also be used to sense a vacuum ranging between 6 inches of water to 65 inches of water. Therefore, these miniature single pole and double pole switches are used as pressure, vacuum, or dierential pressure switches where moderate accuracy is sucient. Presair switches deliver critical benefits: CSPSSGA - PC Mount Switch SAFE: Presair switches deliver complete electrical isolation with zero voltage at the actuator to shock the user or spark an explosion. 1”x1”x1.5” ECONOMICAL:Presair’s switching system costs are comparable or lower than digital controls meeting the needs of original equipment manufacturers. ACCURATE: All switches are 100% tested to meet 100,000+ cycle life. General Specification: RATING: 1 amp resistive 250 VAC Ratings are dependent on actuation pressure and must be derated at lower pressures. APPROVAL: UL Recognized, CUL Recognized. File #E80254 MATERIAL: Lower body: Rynite w/ pin terminals molded Upper body: Acetal Diaphram material is dependent on application. PRESSURE RANGE: When used as a pressure or vacuum switch the actuation point must be factory set.
    [Show full text]
  • Switched-Capacitor Integrator
    EE247 Lecture 10 • Switched-capacitor filters (continued) – Switched-capacitor integrators • DDI & LDI integrators – Effect of parasitic capacitance – Bottom-plate integrator topology – Switched-capacitor resonators – Bandpass filters – Lowpass filters – Switched-capacitor filter design considerations • Termination implementation • Transmission zero implementation • Limitations imposed by non-idealities EECS 247 Lecture 10 Switched-Capacitor Filters © 2008 H. K. Page 1 Switched-Capacitor Integrator C φ φ I φ 1 2 1 Vin - φ 2 Cs Vo + T=1/fs C C φ I φ I 1 2 Vin Vin - - C C s s Vo Vo + + φ High φ 1 2 High Æ C Charged to Vin s ÆCharge transferred from Cs to CI EECS 247 Lecture 10 Switched-Capacitor Filters © 2008 H. K. Page 2 Switched-Capacitor Integrator Output Sampled on φ1 φ φ 1 2 Vin CI φ - 1 Cs Vo Vo1 + φ φ φ φ φ Clock 1 2 1 2 1 Vin VCs Vo Vo1 EECS 247 Lecture 10 Switched-Capacitor Filters © 2008 H. K. Page 3 Switched-Capacitor Integrator ( (n-1)T n-3/2)Ts s (n-1/2)Ts nTs (n+1/2)Ts (n+1)Ts φ φ φ φ φ Clock 1 2 1 2 1 Vin Vs Vo Vo1 Φ 1 Æ Qs [(n-1)Ts]= Cs Vi [(n-1)Ts] , QI [(n-1)Ts] = QI [(n-3/2)Ts] Φ 2 Æ Qs [(n-1/2) Ts] = 0 , QI [(n-1/2) Ts] = QI [(n-1) Ts] + Qs [(n-1) Ts] Φ 1 _Æ Qs [nTs ] = Cs Vi [nTs ] , QI [nTs ] = QI[(n-1) Ts ] + Qs [(n-1) Ts] Since Vo1= - QI /CI & Vi = Qs / Cs Æ CI Vo1(nTs) = CI Vo1 [(n-1) Ts ] -Cs Vi [(n-1) Ts ] EECS 247 Lecture 10 Switched-Capacitor Filters © 2008 H.
    [Show full text]
  • Practical Issues Designing Switched-Capacitor Circuit
    Practical Issues Designing Switched-Capacitor Circuit ECEN 622 (ESS) Fall 2011 Practical Issues Designing Switched-Capacitor Circuit Material partially prepared by Sang Wook Park and Shouli Yan ELEN 622 Fall 2011 1 / 27 Switched-Capacitor practical issues Practical Issues Designing Switched-Capacitor Circuit MOS switch G G S Cov Cox Cov D S D Ron o Excellent Roff o Non-idea Effect Charge injection, Clock feed-through Finite and nonlinear Ron ELEN 622 Fall 2011 2 / 27 Switched-Capacitor practical issues Practical Issues Designing Switched-Capacitor Circuit Charge Injection G Qch1 Qch2 C VS o During TR. is turned on, Qch is formed at channel surface Qch = WLC OX (VGS −Vth ) When TR. is off, Qch1 is absorbed by Vs, but Qch2 is injected to C o Charge injected through overlap capacitor o Appeared as an offset voltage error on C ELEN 622 Fall 2011 3 / 27 Switched-Capacitor practical issues Practical Issues Designing Switched-Capacitor Circuit Charge Injection Effect CLK Ideal sw. Vout MOS sw. 0.1pF 1V CLK o When clock changes from high to low, Qch2 is injected to C o Compared to ideal sw., MOS sw. creates voltage error on Vout ELEN 622 Fall 2011 4 / 27 Switched-Capacitor practical issues Practical Issues Designing Switched-Capacitor Circuit Decrease Charge Injection Effect (1) CLK Vout W/L = 1/0.4 0.1pF 1V W/L = 10/0.4 o Decrease the effect of Qch o Use either bigger C or small TR. (small ratio of Cox/C) o Increased Ron ELEN 622 Fall 2011 5 / 27 Switched-Capacitor practical issues Practical Issues Designing Switched-Capacitor Circuit Decrease Charge Injection Effect (2) CLK CLKb 10/0.4 3.1/0.4 Vout With dummy sw.
    [Show full text]
  • Introduction How Circuit Protection Devices Work?
    Introduction Adding extra strain to any person or object can be a recipe for disaster. This is especially the case for electrical circuits. When they’re tasked with carrying more current than they were designed to handle, the added burden can lead to detrimental and dangerous circumstances. Not only could overloading your circuits damage or destroy your sensitive electronic equipment, but it could also generate extra heat in wires that weren’t meant to carry the load. If this happens, it can cause a fire in a matter of seconds. This is where an overcurrent protection device, such as a fused disconnect switch or a circuit breaker, comes in. Though they serve a similar purpose, these two components each have a unique design. Today, we’re sharing how they work and how to choose the right one for your project. Ready to learn more? Let’s dive in. How Circuit Protection Devices Work? The field of circuit protection technology is vast, designed to prevent circuits from risks associated with overvoltage, overcurrent, reverse-bias, electrostatic-discharge (ESD) and overtemperature events. Such risks include: • High-voltage transients • Capacitive coupling • Inductive kickback • Ground faults • High inrush currents From your smartphone battery to your steering wheel, these components are necessary to ensure safe and reliable electronics. While they all serve a valuable purpose, we’re delving deeper today into the specific field of overcurrent protection. Overcurrent protection devices are designed to disconnect or open a circuit quickly in the event that an overload or short-circuit occurs. This helps to mitigate any damage to the connected equipment and can also reduce the risk of electrical fires.
    [Show full text]
  • Operation and Earthing of System Equipment
    Operation and Earthing of System Equipment Summary: This document supports the Power System Safety Rules and its requirements assembled under: • Operate HV AIS Switchgear – Category 5.5; • Operate HV GIS Switchgear – Category 5.6; • Issue a Field Access Authority – Category 6.4; and • Operate HV AIS Switchgear for work on or near Overhead Lines – Category 6.5. It applies to the operation and earthing of High Voltage switchgear under the direction of the Controller. Document reference no: GD SR G2 004 Revision no: 3 Date: 7 November 2014 Business function: Operate the Network Document type: Safety Rules Work Instruction Process owner: General Manager/System Operations Author: James Mason, Project Coordinator/Network Services & Operations Reviewers: Don Mckay, Network Controller/System Operations Perry Hall, Network Controller/System Operations Geoff Cook, Manager/Operations Planning Approver: Neil Smith, General Manager/System Operations When referring to TransGrid’s policies, frameworks, procedures or work instructions, please use the latest version published on the intranet. Table of Contents 1. Overview ......................................................................................................................................................... 3 1.1. Purpose ................................................................................................................................................. 3 1.2. Policy Base ...........................................................................................................................................
    [Show full text]
  • Power Sense Switch & Fan Control Thermostat
    Speed Controllers & Switches_8_DR_ref.qxd 6/11/2015 10:34 AM Page 17 POWER SENSE SWITCH & FAN CONTROL THERMOSTAT POWER SENSE SWITCH TYPE - VZ-IISNSE TECHNICAL DATA Switched Output Model Number Load Sense Range Max. Amps Enclosure Size, mm On = 2.5 - 15 amp VZ-ISNSE 5 153W x 110H x 60D Off = 0 - 1.5 amps SUGGESTED WIRING ARRANGEMENT The VZ-ISNSE is a 240V AC power sense switch that provides automatic on/off control of a fan or exhaust fan system. The unit detects the current of an appliance such as a clothes dryer, closing and opening the switched output 240V relay when the load sense range Switched Output parameters are met. Can be used with the VZ2-10TS, VZM0-28TS, VZ6-4PL or as a stand alone unit. In LED’s indicate when load is activated. 3-pin Socket Warning Not to be used with fans with EC motors Appliance or inverters. FAN CONTROL THERMOSTAT TECHNICAL DATA Model Temperature Maximum Number range Mounting Amps Dimensions, mm TFC6 5ºC to 30ºC Wall mountable 6.0 86W x 86H x 33D SELECTION TABLE The TFC6 is suitable for most 240-volt fans. The TFC6 can be set in two modes: Cool mode - will start the fan when the room temperature is higher than the set point. The Fantech Fan Control Thermostat has Heat mode - will start the fan when the room temperature is lower than the set point. been developed to control the operation of a 240-volt fan based on the setting made on the thermostat dial. It can be set to turn on a fan when the WIRING DIAGRAM room temperature is either higher or lower than the set point.
    [Show full text]
  • FSW Fuse-Switch-Disconnectors
    Motors | Automation | Energy | Transmission & Distribution | Coatings FSW Fuse-Switch-Disconnectors www.weg.net Fuse-Switch-Disconnectors The FSW Fuse-Switch-Disconnectors, developed according to International Standard IEC 60947-3 and bearing CE certification, are applied in electric circuits in general so as to provide the disconnection and protection against short circuits and overloads by means of NH blade contact fuses. In order to ensure a long lifespan, the FSW Fuse-Switch-Disconnectors are manufactured with reinforced thermoplastic materials and flame retardant. Additionaly, they feature contacts with silver coating, providing low power losses. Safety and Simplicity WEG switch-disconnector has several characteristics which aim at increasing security for operation and maintenance of the equipment, simplifying diagnoses and fuse replacement: g The switch-disconnector allows checking the state of the fuses through a transparent cover, besides featuring small openings which allow making electrical measurements without interrupting the operation. g As per IEC 60947-3, the switch-disconnector can perform the non- frequent opening under load. The FSW series has arc chambers for the extinction of the electric arc and disconnects all the phases together, ensuring full insulation between the load circuit and power supply. g In the opening of the switch-disconnector, the fuses remain fixed to the cover, preventing their drop or accidental contact between the energized parts. Furthermore, the cover is totally removable, allowing simple fuse replacement in a simple and safe area out of the electrical panel. g The switch-disconnectors also feature a built-in auxiliary contact in order to indicate when they are open or not properly closed.
    [Show full text]
  • Thermostats, Thermal Cutoffs & Fuses
    Temperature Controllers Bulb and Capillary Thermostats Thermostat Styles and Selection Construction Characteristics This type of control operates by expansion and contraction of causing the opening and closing of a snap-action switch. For heat- a liquid in response to temperature change. Liquid contained ing applications the contacts are normally closed and open on within the sensing bulb and capillary flexes a diaphragm, temperature rise. See Page 13-77 for typical wiring diagrams. Style A Style B Single-Pole Thermostat Bulb Double-Pole Thermostat ✴ General purpose ✴ Recommended for directly thermostat recommended Pilot Lamp controlling high wattage for most applications. (Optional on loads due to its Style B & ✴ Capable of controlling heavy duty contacts. C ONLY) loads from 120V/30A up ✴ Capable of controlling loads to 480V/20A Knob up to 30 Amps at 277 VAC and (Optional on 10 Amps at 480 VAC all Styles except F) Bezel Capillary (Optional on Style B & C ONLY Thermostat Electrical Ratings: Normally Closed Contacts, Open on Temperature Rise – Adjustable Stock Items Are Shown In RED Temp Ampacity at Bulb Bulb Capillary Thermostat Optional Thermostat Parts Instruction Control Range Line Voltage Dia. Length Length Part Sheet Type Style °F 120V 240V 277V 480V in in in Terminals Number Knob Bezel Pilot Lamp P/N 60–250 30 30 30 — 0.27 6.00 12 #10 screw TST-101-137 TST-104-103 n/a n/a IDP-119-102 60–250 30 30 30 — 0.38 4.63 48 #10 screw TST-101-131 TST-104-103 n/a n/a IDP-119-102 SPST A 70–245 30 30 15 15 0.25 5.50 12 #10 screw TST-101-130 Included
    [Show full text]
  • Safe Isolation of Main Circuits with Switch-Disconnectors N Or with Molded Case Switches NS
    www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, Technical Paper switching and managing power. In industry, in buildings and in Dipl.-Ing. Wolfgang Esser machine construction. Innovative protection concepts. With built-in diagnostics and communication functions. Housed in modern switchboard systems. Circuit-breaker NZM Circuit-breaker IZM Switchboard systems For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Dipl.-Ing. Wolfgang Esser Head of Industrial Switchgear Product Support Business Unit Circuit-Breakers, Motor Starters and Drives Moeller GmbH, Bonn With grateful acknowledgement of the support from: Mr. Andre R. Fortin BA Phys. Moeller Electric Corporation, Millbury, Massachusetts, USA 2 For Moeller Electric Sales and Support call KMparts.com (866) 595-9616 Safe Isolation of Main Circuits with classified – per the newly updated Disconnecting Means, a term that has Switch-Disconnectors N or with IEC / EN 60 947-2, Annex L – to be a become the norm in the meantime. Molded Case Switches NS circuit-breaker without overload release Under certain circumstances and with CBI-X, rather than a switch-disconnector the appropriate identification and - Achieving world market rated switches per IEC / EN 60 947-3. Devices markings, these switches can also in spite of differing demands placed on incorporating short-circuit releases adopt the function of a main supply switches in the IEC world and in North continue to belong exclusively to the Emergency-Stop switch as defined America. - domain reserved for circuit-breakers in under IEC / EN 60 204-1 [1]. most of the world.
    [Show full text]