“Euro” Patio Sauna

Total Page:16

File Type:pdf, Size:1020Kb

“Euro” Patio Sauna “EURO” PATIO SAUNA An attractive variation of the popular Patio Sauna, the Euro outdoor sauna gives greater flexibility on where it can be installed, and a more contemporary European style design. The Euro outdoor sauna includes: • The same features as the standard Patio (see list below). • Roof is single sloped. • Interior can be sauna only or with changing room. • Install under a deck, on a deck, or on other level patio-type surfaces. • Having a backyard sauna has never been easier! PATIO AND EURO PATIO SAUNAS INCLUDE THE FOLLOWING STANDARD FEATURES • Nordic White Spruce walls and ceiling interior, Abachi backrests, headrests, heater guard and duckboard; optional Western Red Cedar or Canadian Hemlock interior • Clear Western Red Cedar exterior • Prebuilt, prefitted wall and ceiling panels all completely blind nailed • Built-in floor with attractive water resistant vinyl flooring • Constructed on cedar runners • Cathedral ceiling on Patio and single-slope ceiling on Euro Patio • Designer Heater with Pure 2.0 digital control • Bucket, ladle, and thermometer • Low voltage backrest lighting • Roof kit in easy-to-install panels Options Available • Metal roof optional on P45, P46, P56 and P57 • Heater Upgrade: Himalaya Enjoy the amazing sauna-and-swim experience with a pool-side Patio Sauna. Euro Patio with woodburner Euro Patio sauna with changing room. PATIO SAUNAS P46 - 4’x6’ * P56 - 5’x6’ * P45 - 4’x5’ * 4x5 (Dashed line = Roof overhang) 4x6 (Dashed line = Roof overhang) 5x6 (Dashed line = Roof overhang) * Dashed line = roof overhang * Dashed line = roof overhang * Dashed line = roof overhang P57 - 5’x7’ * Patio Sauna Includes The Following Standard Features • Interior Nordic White Spruce walls and ceiling, Abachi backrests, headrests, heater guard and duckboard, cedar exterior • Prebuilt, prefitted wall and ceiling panels all completely blind nailed • Built-in floor with attractive water resistant vinyl flooring • Constructed on cedar runners • Cathedral ceiling with exposed wood beams • Heater with control • Bucket, ladle, light, and thermometer • Roof kit in easy-to-install panels * Dashed5x7 (Da slinehed l i=ne roof= Roo overhangf overhang) Options Available: • Metal roof • Heater Upgrades: Himalaya or Pikkutonttu EURO PATIO SAUNAS Euro Patio Sauna Includes The Following Standard Features • Interior Nordic White Spruce walls and ceiling, Abachi backrests, headrests, heater guard and duckboard, cedar exterior • Prebuilt, prefitted wall and ceiling panels all completely blind nailed • Built-in floor with attractive water resistant vinyl flooring • Constructed on cedar runners • Heater with control • Bucket, ladle, light, and thermometer Saunatec CAD shown for shed-style saunas are examples only; can be • Roof kit in easy-to-install panels Saunatec Saunatec custom manufactured to a wide range of sizes and shapes. 72" 84" Options Available: 60" DRAWING # PAKD 45-A-V 24" Upper A 20" Upper A 20" • Metal roofs DRAWING # 24" Upper A DRAWING # INVOICE # PAKD 56-A-V PAKD 57-A-V • Heater Upgrades: HimalayaSCALE: or Pikkutonttu1/2" = 1' INVOICE # INVOICE # 16" Lower B 20" Lower B 48" 20" Lower B SCALE: 1/2" = 1' SCALE: 1/2" = 1' 60" COMPANY: 60" JOB NAME: Duckboard COMPANY:walk area only COMPANY: 24" Upper C JOB NAME:20"x65" JOB NAME: WOOD TYPE: Spruce Duckboard Duckboard Glass Door walk area only walk area only ROOM HEIGHT: . 20"x65" WOOD TYPE: Spruce WOOD TYPE: Spruce 24"x72" Glass Door All-Glass Door ROOM HEIGHT: . ROOM HEIGHT: . Shed Style SHOP USE ONLY Shed Style Base: 58.75" x 46.75" Shed Style SHOP USE ONLY SHOP USE ONLY 69 Outer T&G: Base: 70.75" x 58.75" Base: 82.75" x 58.75" Inner T&G: Outer T&G: Ceiling T&G: Please note walls with plywood exterior Outer T&G: panel-built/modular sauna Inner T&G: Inner T&G: Ceiling T&G: Ceiling T&G: Please note walls with plywood exterior panel-built/modularPlease note walls withsauna plywood exterior panel-built/modular sauna.
Recommended publications
  • BUILDING CONSTRUCTION NOTES.Pdf
    10/21/2014 BUILDING CONSTRUCTION RIO HONDO TRUCK ACADEMY Why do firefighters need to know about Building Construction???? We must understand Building Construction to help us understand the behavior of buildings under fire conditions. Having a fundamental knowledge of buildings is an essential component of the decisiondecision--makingmaking process in successful fireground operations. We have to realize that newer construction methods are not in harmony with fire suppression operations. According to NFPA 1001: Standard for FireFighter Professional Qualifications Firefighter 1 Level ––BasicBasic Construction of doors, windows, and walls and the operation of doors, windows, and locks ––IndicatorsIndicators of potential collapse or roof failure ––EffectsEffects of construction type and elapsed time under fire conditions on structural integrity 1 10/21/2014 NFPA 1001 Firefighter 2 Level ––DangerousDangerous building conditions created by fire and suppression activities ––IndicatorsIndicators of building collapse ––EffectsEffects of fire and suppression activities on wood, masonry, cast iron, steel, reinforced concrete, gypsum wallboard, glass and plaster on lath Money, Money, Money….. Everything comes down to MONEY, including building construction. As John Mittendorf says “ Although certain types of building construction are currently popular with architects, modern practices will be inevitably be replaced by newer, more efficient, more costcost--effectiveeffective methods ”” Considerations include: ––CostCost of Labor ––EquipmentEquipment
    [Show full text]
  • Geodesic Dome Roof
    GEODESIC DOME ROOF The HMT Geodesic Dome features a clear-span, all-aluminum, lightweight, corrosion-resistant structure which sets a new standard for performance in aluminum geodesic domes. HMT’s unique overlapping-panel design and attention to details at critical locations all result in a cost-effective solution that provides superior protection of your stored product. The HMT Geodesic Dome can be installed in-service and its superior design was developed under the guidance of API 650, appendix G and AWWA D-108. Key benefits: Key design features: The HMT Geodesic Dome’s advanced tBatten bar and gasket assembly completely technology provides excellent benefits. Here’s encapsulate panel edges for unparallelled how: sealing Most effective leak-protection solution— tOverlapping panels ensure additional Engineered for maximum weather-tightness for protection against weather both new tanks and retrofits tHub designed with three levels of sealing to Low maintenance — Aluminum alloys are ensure maximum leak protection corrosion resistant and don’t require painting like steel fixed roofs tHub can be easily removed for inspection or Emissions reduction — reduces wind-induced adjustment of IFR support chains vapor loss, aids in odor control and provides tOptions for fixed or sliding rim connections significant emission credits; for light products such as gasoline, a dome installed over an EFR tCan easily handle the weight of suspended can cut emissions by over 90% aluminum internal floating roofs In-service installation — Can be erected on tIndustry-leading 3D design software for the ground beside the tank or on an EFR and maximum accuracy and shorter design time lifted into place Custom engineered— To accommodate a wide range of spans and loading conditions Protecting your world, one tank at a time™ www.hmttank.com THE HMT GEODESIC DOME DESIGN HMT’s design incorporates features which dramatically Triple seal hub design improve upon existing technology.
    [Show full text]
  • Basic Technical Rules the Nubian Vault (Nv)
    PRODUCTION CENTRE INTERNATIONAL PROGRAMME BASIC TECHNICAL RULES v3 BASIC TECHNICAL RULES THE NUBIAN VAULT (NV) TECHNICAL CONCEPT THE NUBIAN VAULT ASSOCIATION (AVN) ADVICE TO MSA CLIENTS Version 3.0 SEASON 2013-2014 COUNTRY INTERNATIONAL Association « la Voûte Nubienne » - 7 rue Jean Jaurès – 34190 Ganges - France February 2015 www.lavoutenubienne.org / [email protected] / +33 (0)4 67 81 21 05 1/14 PRODUCTION CENTRE INTERNATIONAL PROGRAMME BASIC TECHNICAL RULES v3 CONTENTS CONTENTS.............................................................................................................2 1.AN ANCIENT TECHNIQUE, SIMPLIFIED, STANDARDISED & ADAPTED.........................3 2.MAIN FEATURES OF THE NV TECHNIQUE........................................................................4 3.THE MAIN STAGES OF NV CONSTRUCTION.....................................................................5 3.1.EXTRACTION, FABRICATION & TRANSPORT OF MATERIAL....................................5 3.2.CHOOSING THE SITE....................................................................................................5 3.3.MAIN STRUCTURAL WORKS........................................................................................6 3.3.1.Foundations........................................................................................................................................ 6 3.3.2.Load-bearing walls.............................................................................................................................. 7 3.3.3.Arches in load-bearing
    [Show full text]
  • Insulating Thatched Roofs This Guidance Note Has Been Prepared and Edited by David Pickles
    Energy Efficiency and Historic Buildings Insulating Thatched Roofs This guidance note has been prepared and edited by David Pickles. It forms one of a series of thirteen guidance notes covering the thermal upgrading of building elements such as roofs, walls and floors. First published by English Heritage March 2012. This edition (v1.1) published by Historic England April 2016. All images © Historic England unless otherwise stated. Illustrations drawn by Simon Revill. Our full range of guidance on energy efficiency can be found at: HistoricEngland.org.uk/energyefficiency Front cover: Thatch repairs in progress. © Philip White. Summary This guidance provides advice on the principles, risks, materials and methods for insulating thatched roofs. There are estimated to be about fifty thousand thatched buildings in England today, some of which retain thatch which is over six hundred years old. Thatching reflects strong vernacular traditions all over the country. Well-maintained thatch is a highly effective weatherproof coating as traditional deep thatched eaves will shed rainwater without the need for any down pipes or gutters. Locally grown thatch is a sustainable material, which has little impact on the environment throughout its life-cycle. It requires no chemicals to grow, can be harvested by hand or using traditional farm machinery, requires no mechanical processing and therefore has low embodied energy and can be fixed using hand tools. At the end of its life it can be composted and returned to the land. Thatch has a much greater insulating value than any other traditional roof covering. With the right choice of material and detailing, a well-maintained thatched roof will keep a building warm in winter and cool in summer and has the added advantage of being highly sound-proof.
    [Show full text]
  • Replacing the Roof on Your Manufactured Or Mobile Home Protectmymanufacturedhome
    What You Should Know: Replacing the roof on your manufactured or mobile home ProtectMyManufacturedHome An alteration permit from the Washington State Department of Labor & Industries is required when you reroof a manufactured home. In some cases, plans for the work must also be submitted to L&I for approval prior to doing the work. L&I has a four-step process for home alterations. Here’s how: Step 1: See if you need to submit plans. You need to submit plans if: You are not removing the old shingles or roof covering before installing the new roofing. The new roof covering is heavier than the original. There are repairs to any roof framing, such as trusses or rafters. A second layer of sheathing or additional framing is added to the roof. Plans must be stamped by a Washington professional engineer (PE) or architect. When you reroof, you need to submit plans when buying a permit (see step 2). There is a fee for reviewing plans which is added to the permit. Get more information It usually takes two to three weeks to process plans and plans must be approved before proceeding with the work. Visit www.Lni.wa.gov/FAS You do not need to submit plans if: For structural issues, contact plan review at: 360-902-5218 You are removing the existing roofing and installing For general permit help, call customer new roofing of the same or lesser weight. service at: 360-902-5206 Existing roof sheathing may be removed and new roof Or email [email protected] sheathing used.
    [Show full text]
  • Installers' Handbook Preface
    HANDBOEK VOOR INSTALLATEURS Handboek voor de installatie van VELUX dakvensters Installers' handbook Preface The purpose of this handbook is to provide an overview of the installation of VELUX products. The handbook describes the various aspects of roof construction in association with VELUX roof windows and also provides advice and information on how to obtain the optimal installation. (Third edition, 2010) The VELUX system Chapter 1 2 3 4 5 6 7 8 Other products Chapter 9 Contents Planning Considerations before choosing roof window 5-13 1 Installation of a roof window Installation step by step 15-25 2 Integration – more windows Combination of more than one window 27-45 3 Special installation conditions Installation in various roof constructions 47-63 4 Special roofing materials Installation in various roof materials 65-81 5 Replacement / renovation Replacement of a roof window 83-93 6 Building physics Roof constructions (humidity, heat, sound etc) 95-109 7 Product information Short presentation of VELUX products 111-137 8 Other products Sun tunnel / Flat roof window / Solar hot water system 139-145 9 Contact VELUX Addresses / Advising / Service 146-147 List of telephone numbers 148 Size chart 151 Planning 1 The construction of the house 6-7 User requirements 8 Building regulations 9-13 VELUX 5 Planning 1 The construction of the house To be able to choose the right VELUX roof window for a given situ- ation, it is always recommended to start from the construction of the house, user requirements and current building regulations. Normally, a standard VELUX roof window can satisfy the basic requirements, but often choosing another window type or vari- ant and/or choosing accessories can optimise the function and increase the utility value of the window.
    [Show full text]
  • Top-Operated Centre-Pivot Polyurethane Roof Window GLU 0061
    Edition 2.0 – 05.04.2017 Product information Top-operated centre-pivot polyurethane roof window GLU 0061 Product description High quality moulded polyurethane with white lacquer finish Triple insulating glass unit with Uw 1.1 Top control bar for easy operation even with furniture under the window Integrated ventilation in top control bar and cleanable dust and insect filter Maintenance-free interior surface Maintenance-free exterior covers Roof pitch Can be installed in roof pitches between 15° and 90° Materials Polyurethane around a core of thermally modified timber Glass; float glass / strengthened glass / toughened glass Lacquered aluminium VELUX ThermoTechnology™ insulation Downloads For installation instructions, CAD drawings, 3D BIM objects, 3D GDL objects etc, please visit velux.bg. Certifications The VELUX product EUTR In compliance with the EU Timber factories guarantee Regulation (EUTR), EU regulation quality systems 995/2010 implementation process and environmental REACH We are aware of the REACH regulation management systems and acknowledge the obligations. No through appropriate products are obliged to be registered in accreditations ISO accordance to REACH and none of our 9001 and ISO 14001 products contain any Substances of Very High Concern. Available sizes and daylight area Lining measurements 472 550 660 mm 780 mm 942 mm 1140 mm 1340 mm Size Width (mm) mm mm GLU p CK-- 495 CK02 mm FK-- 605 78 7 (0.22) MK-- 725 GLU MK04 PK-- 887 m m SK-- 1085 78 9 (0.47) Size Height (mm) GLU GLU FK06 MK06 --02 719 m m --04 919 78 11 --06 1119 (0.47) (0.59) GLU GLU GLU GLU --08 1339 FK08 MK08 PK08 SK08 --10 1549 m 398 m 398 1 (0.58) (0.72) (0.92) (1.16) GLU MK10 1600mm (0.85) ( ) = Effective daylight area, m2 Top-operated centre-pivot roof windows make it possible to place furniture directly below the window without obstructing operation of the window.
    [Show full text]
  • Best Practices Single-Family Residences
    SITE PLANNING best practices single-family residences for aesthetic review by the city of coral gables board of architects 2018 1 SINGLE-FAMILY RESIDENCE BEST PRACTICES July 2018 table of contents 1. Purpose & Uses 2. Site Planning 3. Architecture 4. Checklist Purpose & Uses The purpose of the City of Coral Gables, Florida Zoning Code is to implement the Comprehensive Plan (CP) of the City pursuant to Chapter 163, Florida Statutes for the protection and promotion of the safety, health, comfort, morals, convenience, peace, prosperity, appearance and general welfare of the City and its inhabitants. ~ Zoning Code Section 1-103 Purpose of the City of Coral Gables Zoning Code PURPOSE & USE Single-Family Residential (SFR) District The Single-Family Residential (SFR) District is intended to accommodate low density, single-family dwelling units with adequate yards and open space that characterize the residential neighborhoods of the city. The city is unique not only in South Florida but in the country for its historic and archi- tectural treasures, its leafy canopy, and its well-defined and livable neighborhoods. These residential areas, with tree-lined streets and architecture of harmonious proportion and human scale, provide an oasis of charm and tranquility in the midst of an increasingly built-up metropolitan environment. The intent of the Single-Family Residential code is to protect the distinctive character of the city, while encouraging excellent architectural design that is responsible and responsive to the individual context of the city’s diverse neighborhoods. The single-family regulations, as well as the design and performance standards in the Zoning Code, seek to ensure that the renovation of residences as well as the building of residences is in accord with the civic pride and sense of stewardship felt by the citizens of Coral Gables.
    [Show full text]
  • Feet) Zoning Districts Min. Lot Size (Sq. Ft.
    CHARTER TOWNSHIP OF BREITUNG Minimum Set Backs (Feet) Min. Min. Max. Zoning Min. Lot Size Lot Building Front Side Rear Height Districts (Sq. Ft.) Width Width (Feet) (Feet) (Feet) R-1 20,000A 100 30 10B 10C 30D 20 A. Minimum lot size is 10,800 square feet where either municipal water or sewer service is provided to the lot. No more than 30% of the lot area may be covered by buildings. On lots less than 20,000 square feet the setbacks shall be reduced to 25-foot minimum front, 6-foot minimum side and 6-foot minimum rear. The minimum lot width shall remain 100 feet. B. An accessory building or structure may be located 6 feet from a side lot line. C. An accessory building or structure may be located 6 feet from a rear lot line. D. An accessory building or structure shall not exceed 18 feet in height. § 150.022 DISTRICT R-1: RESIDENTIAL ONE. (A) Intent. The R-1, Residential One District is intended for the establishment and preservation of quiet single-family home neighborhoods free from other uses, except those which are both compatible with and convenient to the residents of this District. The R-1 District is designed to accommodate residential opportunities where spacious lots are reasonable to insure a safe, potable water supply and treatment of wastewater on the same lot. (B) Principal permitted uses. (1) Single-family dwellings. (2) State licensed residential care facilities for six or fewer persons. (See definition.) (3) Foster family homes (one to four children) and foster group homes (five to six children).
    [Show full text]
  • Discover the Sauna of the Future. Discover the Sauna S1 from Klafs. 4 / 5
    S1 EXHILARATINGLY NEW. EXHILARATINGLY DIFFERENT. EXHILARATINGLY BEAUTIFUL. DISCOVER THE SAUNA OF THE FUTURE. DISCOVER THE SAUNA S1 FROM KLAFS. 4 / 5 FITS. EASILY. ANYWHERE. A SAUNA SPELLS QUALITY OF LIFE. MANY OF US SIMPLY CAN’T IMAGINE LIFE WITHOUT A CHANCE TO WIND DOWN, TO RELAX, TO REST. BUT A SAUNA NEEDS ROOM. Room that we don’t always have. That is why KLAFS has designed the space-saving Sauna S1: a sauna innovation that fits perfectly in our modern life, wherever that may be – in a single-family home, a pre-war apartment, a loft, or a vacation home. An innovation whose intelligent use of space opens the door to matchless moments of well-being. 5 THE NEW SAUNA S1 FROM KLAFS 8TH FLOOR 120 m2 FLOOR SPACE FITS. EASILY. ANYWHERE. 6 / 7 AS MUCH SAUNA AS POSSIBLE. THE NEW SAUNA S1 IS THE FIRST IN THE WORLD THAT CAN RETRACT AT THE TOUCH OF A BUTTON – JUST LIKE A ZOOM LENS ON A CAMERA. When retracted, the Sauna S1 is a svelte 60 cm and no deeper than the average closet. When extended, the Sauna S1’s 1.60 m depth offers plenty of room to enjoy a relaxing sauna. SUPER SPACE-SAVER: Press the button on the display in front, and the new Sauna S1 opens in just 20 seconds, from standby mode to up and running. 7 THE NEW SAUNA S1 FROM KLAFS IN AS LITTLE SPACE AS NECESSARY. 60 cm DEPTH FITS. EASILY. ANYWHERE. 8 / 9 FROM ZERO TO SAUNA IN 20 SECONDS: eMOVE TECHNOLOGY.
    [Show full text]
  • Roof Window Size Comparison
    Roof Windows Roof Window Size Comparison keyliteroofwindows.com Comparison Chart Futuretherm Technology Height (mm) Width (mm) 550 660 780 940 1140 1340 01 03A 04A 07A 08A 09A Keylite CK02 N/A N/A N/A N/A N/A Velux 780 01 22 23 24 25 26 Fakro 02 03B 04 07B 08B 09 Keylite CK04 FK04 MK04 PK04 N/A UK04 Velux 980 02 03 05 15 N/A 12 Fakro 01C 03 05 07C 08 09C Keylite CK06 FK06 MK06 PK06 SK06 N/A Velux 1180 16 04 06 08 10 N/A Fakro 01F 03F 06 07F 08F 10 Keylite N/A FK08 MK08 PK08 SK08 UK08 Velux 1400 N/A N/A 07 09 11 N/A Fakro Keylite 1600 01G 03G 04G 07G 08G 09G Velux N/A N/A MK10 PK10 SK10 UK10 Fakro N/A N/A 13 N/A N/A N/A Centre Pivot Roof Windows Pine White Conservation Pine Conservation White Keylite CP WF-CP CW-CP CW-WF-CP Velux GGL GGU GGL SD5 GGU SD5 Fakro FTP-V FTU-V & PTP-V FTP-V/C PTP-V/C Top Hung / Fire Escape Pine White Conservation Pine Conservation White Keylite FE WF-FE CW-FE CW-WF-FE Velux GPL GPU GPL SD5 GPU SD5 FPP-V & FPU-V & FPP-V/C & FPU-V/C & Fakro FHP-V FHU-V FHP-V/C FHU-V/C Single Flashings Slate Tile Deep Plain Tile Conservation Conservation Conservation Conservation Corrugated Tile Slate Tile Plain Tie Deep Tile Keylite SRF TRF DTRF PTRF CWSRF CWTRF CWPTRF CWDTRF CRF (Recessed As Standard) Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Standard Recessed Velux EDL/ EDN EDZ N/A EDW/ EDJ EDP/ N/A N/A EDN N/A N/A EDP N/A EDW EDJ ZWC EBL/ EBW/ EBP/ EKL EKW EKP Fakro EL N/A EZ N/A EH N/A EP N/A /C N/A /C N/A /C N/A /C N/A EE Combi Flashings 18mm
    [Show full text]
  • Technical Summary
    TM NEW CONSTRUCTION HURRICANE TECHNICAL SUMMARY 2019 FORTIFIED HOME™ Technical Requirements INTRODUCTION New Home This FORTIFIED Home™ standard helps homeowners in coastal areas strengthen their houses against hurricanes. Incorporating FORTIFIED features when repairing, rebuilding, or renovating your home will transform your house into a more resilient and durable property. The FORTIFIED features focus first on strengthening and protecting the roof because it is the home’s first line of defense against severe weather events. This includes things like sealing the roof deck to prevent wind-driven rain from getting inside and using a roof covering that is rated for the wind speeds in your area to reduce the chances it will lift up or blow off during high winds. Protecting the openings in the house, things like entry doors, windows, and especially garage doors, is also important. Creating a continuous load path by tying the roof to the walls, the wall above to the wall below, and the first floor walls to the foundation will significantly strengthen your home when Mother Nature strikes. There are three levels of FORTIFIED Home: 1. FORTIFIED Roof™ — focus is on the roof 2. FORTIFIED Silver™ — focus is on roof overhangs, opening protection, gable ends, and attached structures 3. FORTIFIED Gold™ — focus is on tying all components of the structure together For more detailed information about how to make your home stronger, safer, and more hurricane-resistant, please visit www.DisasterSafety.org/FORTIFIED. You can also follow us on Twitter at @DisasterSafety and on Facebook at www.facebook.com/buildfortified. Page 1 of 7 FORTIFIED HOME™ Hazard: Hurricane Technical Requirements Applicable where the design wind speed for Vult in accordance New Home with ASCE 7-10 (or 7-16) exceeds 115 mph, or Vasd in accordance with ASCE 7-05 exceeds 90 mph.
    [Show full text]