6 S 0 T F 9Cn (Avo,C,$)?.,?__
Total Page:16
File Type:pdf, Size:1020Kb
HQ NATIONAL SECURITY GUARD (Provisioning Branch : Ord Section) PLACING OF DRAFT QRs AND TRIAL DIRECTIVES OF BOMB SUIT 1. Please refer PM Division, MHA letter No. IV-24011/14/2016-Prov.l-2405 dated 05 Oct 2017, letter No. 1V-24011/12/2011-Prov.1 dated 13 Jun 2012 and letter No 11012/02/2009- Fin-l/Prov-1-17 dated 02 Jan 2018. 2. Meeting of sub group of technical experts was held on 23 Feb 2021 at 1030 in the conference Hall, HQ NSG for the QRs and Trial Directives of Bomp Suit. 3. The sub group during the meeting opined that the QRs and Trial Directives of Bomb Suit be placed on MHA as well as NSG website for 15 days to invite vendor comments/ suggestions. 4. As per PM Division, letter under reference, the draft QRs and Trial Directives of Bomb Suit is forwarded herewith in hard and soft copy as per appendix attached for hosting on the MHA website. 6 (Rakesh Kumar) Group Commander Encls :- As above. Technical Director, NIC, North Block, New Delhi No. P/604/19(389)/BomB Suit/Prov (Ord)/HQ NSG !WI Dated, theOL_Mar 2021 S 0 T f 9cn (Avo,c,$)?.,?__ INVITATION OF VENDOR COMMENTS ON QR/ TDs OF BOMB SUIT 1. It is intimated that firms/ vendors' comments are invited on the QR/ TDs of Bomb Suit. All firms are requested to offer their comments on e-mail address scordna or qcprocAnsq.qov.in in under mention format. QRs TDs Comments by the firm 2. You are requested to offer comments within 15 days from the date of uploading on the website. The QR/ TDs of above mentioned equipment/ weapon are being considered by sub group committee meeting for finalization. Dated : ).,--Mar 2021 (Rakesh Kumar) Group Commander DRAFT OR AND TRIAL DIRECTIVES FOR BOMB SUIT Sr. QR's Trial directives No. 1) Bomb Disposal Suit is used to protect the operator/technician from blast/heat & fragmentation OEM to furnish NATO STANAG 2920 or MIL effect of bomb/ IED (Improvised Explosive Device) during handling of bomb/IED Standard 662F or NIJ 0117.01 test certificate. 1.1) Bomb suit should be designed to protect against IEDs with acceptable standards of OEM to furnish live test reports from NABU ergonomics, optics, head protection; spine protection, fragmentation protection, blast integrity, international accredited lab for protection electrostatic discharge safety, flammability safety and Drag rescue features. standards offered by the Bomb Suit. 1.2) Protection aoainst Threats: The Bomb Suit should offer protection against following effects of To be checked physically by BOO by relevant bomMED explosion. test certificates from NABU international • Fragmentation. accredited lab for protection standards offered - Impact. by the Bomb Suit. Blast Over pressure. Thermal effect. 1.3) Body Protection: Following parts of the body should be protected from the explosion effect of OEM to furnish live test reports from NABU bomb/IEDs:- international lab for protection standards • Arms offered by the Bomb Suit. Feet, Lower leg, Knees & Thighs. • Chest, Groin & Collar. Spinal cord. • Face (with helmet & visor). - Head, Thorax, Abdomen and Pelvis Or( 2 DRAFT QR AND TRIAL DIRECTIVES FOR BOMB SUIT Sr. QR's Trial directives No. 1.4) The suit should consist of the following items, which collectively make a complete garment:- (a) Jacket with attached adjustable collar & patch chord, with additional plate for enhanced protection of To be checked physically by BOO. chest, neck and groin (b) Trouser adjustable To be checked physically by BOO. (c) Foot protection with the help of boot over shoes or similar arrangement. To be checked physically by BOO. (d) Helmet Helmet — To be of adjustable size without compromising the comfort of bomb technician consisting of following : - (i) Visor ( Replaceable when damaged) (ii) Adjustable helmet size (iii) Visor cover. (iv) Balaclava. To be checked physically by BOO. (v) Ear protection. (vi) Ventilation system with Blower. (vii) Power supply. (viii) Minimum one front facing live video camera. (ix) Minimum one front facing search light. (x) Communication system. Built in microphones and headphones/ integral radio communication in helmet facilitating clear communication between bomb technician and commander without compromising the comfort of the bomb technician. (e) Flame resistant non-static hand gloves (detachable). OEM to furnish live test reports from NABU international lab for flame and static electricity protection standards offered by the gloves. 100 3 DRAFT CR AND TRIAL DIRECTIVES FOR BOMB SUIT Sr. OR's No. Trial directives (f) Transit bag :- To be physically checked by BOO (i) Soft carrying Bag(s) for trouser, jacket, helmet, communication system & cooling suit kit. (H) Hard.. case for trouser, jacket, helmet, communication system & cooling suit kit for storage and transportation. (g) Groin protection To be checked physically by BOO. (h) Hydration bag To be checked physically by BOO. (i) Complete body cooling suit. (i) Cooling Trouser To be checked physically by BOO. (ii) Cooling Jacket (iii) Cooling Balaclava for head and face. (iv) Water bottles (v) Pump unit (k) Communication system. To be checked physically by BOO. (i) Wireless hands-free (VOX) Communication without use of PTT (ii) Wireless range of 200 mtrs (Min) (Hi) Hard Wire Spool 100 mtrs (Min) (iv) Control Module cum amplifier for communication system. (v) Recording facility for recording live communication. (vi) Head set (vii) Built in microphones and headphones/ integral radio communication in helmet facilitating clear communication between bomb technician and commander without comprising the comfort of the bomb technician. (I) Custom Size to be made available according to the user requirement specified at tendering stage. To be checked physically by BOO (m) Back protector with easy adjustment as per best fit for bomb technicians comfort To be physically checked by BOO. 2) The suit protection performance figures should be for NIJ 0117.01 or NATO STANAG 2920 or MIL Standard OEM to furnish test report from NABU 662F17 grain fragment simulator VO protection level to be as under- international lab for protection standards offered by the Bomb Suit. (i) Front Chest — 1800 m/Sec or better To be checked physically by BOO by relevant test certificates. (ii) Front Groin - 1800 m/Sec or better To be checked physically by BOO by X — ---- 1 relevant test certificates. Vs< 4 -• - - . •,, ........• • ...D...ant-n-1/4.o iv GJ §- WIN CI1J111113 JIM I Sr. QR's No. Trial directives 2.1) The suit protection performance figures should be of NIJ 0117.01 or OEM to furnish test report from NABL/ international lab for protection NATO STANAG 2920 or MIL Standard 662F. 17 grain fragment simulator standards offered by the Bomb Suit. V50 protection levels to be as under- (i) Jacket Front 600 M/s. or Better To be checked physically by BOO by relevant test certificates. (ii) Jacket Rear 550 M/s. or Better To be checked physically by BOO by relevant test certificates. (Hi) Sleeves Front — 560 M/Sec or better To be checked physically by BOO by relevant test certificates. (iv) Sleeve Rear- 450 M/s. or Better To be checked physically by BOO by relevant test certificates. (v) Collar Front — 850 M/Sec or better To be checked physically by BOO by relevant test certificates. (vi) Collar rear : - 450M/s. To be checked physically by BOO by relevant test certificates. (vii) Front Groin- 500 M/s. or Better To be checked physically by BOO by relevant test certificates. (viii) Rear Groin- 325 M/s. or Better To be checked physically by BOO by relevant test certificates. (ix) Trousers Front Thighs— 690 M/Sec or better To be checked physically by BOO by relevant test certificates. (x) Trousers Front Shins — 620 M/Sec or better To be checked physically by BOO by relevant test certificates. (xi) Rear Trousers- 325 M/s. or Better. To be checked physically by BOO by relevant test certificates. (xii) Boots- 450 M/Sec or better To be checked physically by BOO by relevant test certificates. 2.2) The Bomb Suit should provide demonstrable integrity and performance OEM to furnish report from NABU international lab for protection against blast by effectively reducing the blast over pressure and shock standards offered by the Bomb Suit against shock wave and blast wave effect below the injury threshold of professionally acceptable head overpressure. injury, lung injury and ear injury criteria. 3. Cooling Suit 3.1 The Cooling Suit kit should include- (a) Long sleeve shirt with cooling tubes sewn into trunk and arms. To be physically checked by BOO and OEM to furnish self declaration (b) Long legged pants with cooling tubes sewn into legs. certificate with regard to commercial availability of Battery in the market (c) A closed fitted open faced hood for head. (d) Cooling unit and pouch. (e) Two water bottles with capacity ranging from 01 to 1.5 litre. (0 Battery pack and charge- Battery pack to provide minimum backup of 2.5 hrs and battery to be commercially available in the market. (g) Carrying bag. (h) Water pump. j) Complete Cooling suit after duly worn by the bomb technician to provide operational efficiency with respect to cooling provided to Bomb Technician for min 30 minutes 5 DRAFT QR AND TRIAL DIRECTIVES FOR BOMB SUIT Sr No Q Rs 3.2 (a) Trial directives Material: Manufactured from a suitable flame retardant knitted fabric. Should have To be checked physically by BOO and OEM to furnish negligible pilling, flexible, very soft ,comfortable to wear and can be worn under self declaration certificate virtually any outer clothing without encumbrance. It should be available as detachable shirt, pant & hood. The fabric should be washable. (b) The cooling suit should have integrated tubes for circulation of cooling water with a To be checked physically by BOO.