AAC

All Aluminum Conductor, Bare Construction Aluminum 1350-H19 , concentrically stranded.

Specifications Meets or exceeds the following ASTM specifications: • B-230 Aluminum , 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded See referenced page in the Applications Hardware & Supplies section: Classes* AA and A are used primarily for overhead transmission and Suggested Prep Tool primary and secondary distribution where ampacity must be maintained • Cable End Strippers and a lighter conductor (compared to ACSR) is desired, when conductor 2x2, 4x4 - I-9 strength is not a critical factor. Classes B and C are used primarily as bus, apparatus connectors and jumpers where additional flexibility is required.

*Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least flexible, C the most flexible.

Resistance Stranding (Ohms/M-ft) Size (AWG Individual Complete Allowable Ampacity Code Word or kcmils) No. of Wires Class Wire Dia. (in) Cable Dia. (in) DC @ 20˚C AC @ 20˚C (amps) Iris 2 7 AA, A .0974 .292 .26000 .31800 185 Poppy 1/0 7 AA, A .1228 .368 .16400 .20000 247 Aster 2/0 7 AA, A .1379 .414 .13000 .15900 286 Phlox 3/0 7 AA, A .1548 .464 .10300 .12600 331 Oxlip 4/0 7 AA, A .1739 .522 .08170 .09990 383 Laurel 266.8 19 A .1185 .592 .06480 .07930 444 Tulip 336.4 19 A .1331 .665 .05140 .06300 513 Daffodil 350 19 A .1357 .679 .04940 .06050 526 Canna 397.5 19 AA, A .1446 .723 .04350 .05340 570 Cosmos 477 19 AA .1584 .792 .03620 .04450 639 Dahlia 556.5 19 AA .1711 .856 .03110 .03820 703 Mistletoe 556.5 37 AA .1226 .858 .03110 .03820 704 Meadowsweet 600 37 AA .1273 .891 .02280 .03550 738 Orchid 636 37 AA, A .1311 .918 .02720 .03550 765 Petunia 750 37 AA .1424 .997 .02300 .02860 847 Arbutus 795 37 AA .1466 1.026 .02170 .02700 878 Magnolia 954 37 AA .1606 1.124 .01810 .02260 982 Bluebell 1033.5 37 AA .1671 1.170 .01670 .02100 1031 Narcissus 1272 61 AA, A .1444 1.300 .01360 .01730 1169 Coreopsis 1590 61 AA .1614 1.453 .01090 .01410 1333 Lupine 2500 91 A .1657 1.823 .00698 .00969 1706 Other cables not listed here may be available upon request. Information based on Southwire specs.

www.ptsupply.com 1 [email protected] 800-238-7514 ACSR

Aluminum Conductor, Steel Reinforced Construction Aluminum alloy 1350-H19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum-clad (AW). Additional protection is available through the application of grease to the core or infusion of the complete cable with grease. See referenced page in the Hardware & Supplies section: Specifications Suggested Prep Tool Meets or exceeds the following ASTM specifications: • Cable End Strippers • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 2x2, 4x4 - I-9 • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced for ACSR • B-341 Aluminum-Coated Steel Core Wire for ACSR/AZ • B-498 Zinc-Coated Steel Core Wire for ACSR • B-802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for ACSR

Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

Individual Wire Diameter (in) Resistance Dia. (in) (Ohms/M-ft) Stranding Steel Complete Weight Allowable Code Word AWG (Alum./Stl.) AIum. Steel Core Cable (lbs/M-ft) DC @ 20˚C AC @ 20˚C Ampacity (amps) Swanate 4 7/1 .0772 .1030 .1030 .257 67 .3990 .5190 140 Sparrow 2 6/1 .1052 .1052 .1052 .316 91 .2540 .3320 184 Sparate 2 7/1 .0974 .1298 .1298 .325 107 .2510 .3380 184 Raven 1/0 6/1 .1327 .1327 .1327 .398 145 .1590 .2170 242 Quail 2/0 6/1 .1489 .1489 .1489 .447 183 .1260 .1760 276 Pigeon 3/0 6/1 .1672 .1672 .1672 .502 230 .1000 .1440 315 Penguin 4/0 6/1 .1878 .1878 .1878 .563 291 .0795 .1190 357 Merlin 336.4 18/1 .1367 .1367 .1367 .684 365 .0510 .0625 519 Linnet 336.4 26/7 .1137 .0885 .2654 .720 462 .0505 .0618 529 Pelican 477 18/1 .1628 .1628 .1628 .814 517 .0360 .0442 646 Drake 795 26/7 .1749 .1360 .4080 1.107 1093 .0214 .0263 907 Other cables not listed here may be available upon request. Information based on Southwire specs.

2 www.ptsupply.com [email protected] 800-238-7514 Covered Line Wire, Aluminum

Covered Line Wire Aluminum Conductor Construction Aluminum alloy 1350-H19, 6201 or ACSR conductors, concentrically stranded. Covered with PE or XLP.

Specifications Meets or exceeds the following ASTM specifications: See referenced page in the • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes Hardware & Supplies section: • B-231 Aluminum Conductors, Concentric-Lay-Stranded Suggested Prep Tool • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel • Cable End Strippers Reinforced (ACSR) 2x2, 4x4 - I-9 • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

Applications Used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as a bare conductor.

Weight (lbs/M-ft) Size Cover Total Diameter Code Word (AWG or kcmils) Stranding Thickness (mils) (mils) XLP Conv. Poly. Allowable Ampacity 6201 Aluminum Alloy *Oilnut 1/0 7 60 518 159 159 250 *Waterash 2/0 7 60 567 195 195 290 *Planetree 4/0 7 60 683 297 297 385 All-Aluminum Pear 4 1 30 264 47 47 135 Peach 2 7 45 373 84 84 180 Quince 1/0 7 60 477 136 136 240 Orange 2/0 7 60 522 167 167 280 Olive 4/0 7 60 626 253 253 370 Pomegranate 4/0 19 60 632 247 247 370 Mulberry 266.8 19 60 694 305 305 430 Annona 336.4 19 60 765 377 377 495 Huckleberry 477 37 80 931 538 538 610 Paw Paw 556.5 37 80 992 619 619 670 Breadfruit 636 61 95 1,081 715 715 720 Persimmon 795 61 95 1,186 877 877 825 Grapefruit 1,033.5 61 95 1,326 - 1,118 970 ACSR Butternut 4 6/1 30 310 72 72 135 Hickory 4 7/1 30 317 83 83 135 Pignut 2 6/1 45 406 118 118 180 Almond 1/0 6/1 60 518 190 190 235 Pecan 2/0 6/1 60 567 233 233 270 Filbert 3/0 6/1 60 622 288 288 305 Buckeye 4/0 6/1 60 683 357 357 345 *AWG equivalent to ACSR construction or 1350 aluminum equivalent. Other cables not listed here may be available upon request. Information based on Southwire specs. www.ptsupply.com 3 [email protected] 800-238-7514 Duplex Service Drop

Duplex Service Drop Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either PE or XLP. Neutral messengers are concentrically stranded 6201, AAC or ACSR.

Specifications Meets or exceeds the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors • B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

Applications Primarily used for 120V overhead service applications such as street lighting, outdoor lighting and temporary service for construction. To be used at of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for PE insulated conductors or 90°C for XLP insulated conductors.

Phase Bare Neutral Weight Allowed Conductor Messenger (lbs/M-ft) Ampacities

Code Word* AWG Stranding AWG Stranding XLP PE XLP PE 6201 Alloy Neutral-Messenger Chihuahua 6 1 6 7 65 65 85 70 Vizsla 6 7 6 7 68 68 85 70 Harrier 4 1 4 7 99 99 115 90 Whippet 4 7 4 7 103 103 115 90 Schnauzer 2 7 2 7 157 157 150 120 Heeler 1/0 9 1/0 7 250 250 205 160 AAC Neutral-Messenger Pekingese 6 1 6 7 61 61 85 70 Collie 6 7 6 7 64 64 85 70 Dachshund 4 1 4 7 92 92 115 90 Spaniel 4 7 4 7 96 96 115 90 Doberman 2 7 2 7 147 147 150 120 Malemute 1/0 9 1/0 7 234 234 205 160 ACSR Neutral-Messenger Setter 6 1 6 6/1 72 72 85 70 Shepherd 6 7 6 6/1 75 75 85 70 Eskimo 4 1 4 6/1 110 110 115 90 Terrier 4 7 4 6/1 115 115 115 90 Chow 2 7 2 6/1 176 176 150 120 See referenced page in the Bull 1/0 9 1/0 6/1 280 280 205 160 Hardware & Supplies section: Information based on Southwire specs. *Code word for XLP insulated products are formed by adding Suggested Prep Tool /XLP to the conventional code word (e.g. Chihuahua/XLP). • Cable End Strippers 2x2, 4x4 - I-9

4 www.ptsupply.com [email protected] 800-238-7514 Triplex Service Drop

Triplex Service Drop Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either PE or XLP. Neutral messengers are concentrically stranded 6201, AAC or ACSR.

Specifications Meets or exceeds the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-399 Stranded 6201-T81 Aluminum Alloy Conductors • B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Applications Used to supply power, usually from a pole-mounted , to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for PE insulated conductors or 90°C for XLP insulated conductors.

Phase Bare Neutral Weight Allowed Conductor Messenger (lbs/M-ft) Ampacity

Code Word* AWG Stranding AWG Stranding XLP PE XLP PE 6201 Alloy Neutral-Messenger Hippa 6 7 6 7 107 107 85 70 Barnacle 4 7 4 7 160 160 115 90 Shrimp 2 7 2 7 243 243 150 120 6201 Alloy Reduced Neutral-Messenger Crab 4 7 6 7 143 143 115 90 AAC Neutral-Messenger Patella 6 7 6 7 103 103 85 70 Oyster 4 7 4 7 154 154 115 90 ACSR Neutral-Messenger Paludina 6 1 6 6/1 109 109 85 70 Whelk 4 1 4 6/1 - 164 115 90 Periwinkle 4 7 4 6/1 172 172 115 90 Neritina 1/0 7 1/0 6/1 420 420 205 160 Runcina 2/0 7 2/0 6/1 520 520 235 185 Zuzara 4/0 18 4/0 6/1 789 789 315 245 ACSR Reduced Neutral-Messenger Strombus 4 7 6 6/1 151 151 115 90 Cockle 2 7 4 6/1 228 228 150 120 See referenced page in the Janthina 1/0 7 2 6/1 366 366 205 160 Hardware & Supplies section: Cerapus 4/0 18 2/0 6/1 681 681 315 245 Suggested Prep Tool *Code word for XLP insulated products are formed by adding Information based on Southwire specs. /XLP to the conventional code word (e.g. Hippa/XLP). • Cable End Strippers 2x2, 4x4 - I-9 Other cables not listed here may be available upon request.

www.ptsupply.com 5 [email protected] 800-238-7514 Quadruplex Service Drop

Quadruplex Service Drop Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either PE or XLP. Neutral messengers are concentrically stranded 6201, AAC or ACSR. Conductors are manufactured with ridges for phase identification (one conductor one ridge, one conductor two ridges, one conductor plain).

Specifications Meets or exceeds the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors • B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Applications Used to supply three-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for PE insulated conductors or 90°C for XLP insulated conductors.

Phase Bare Neutral Conductor Messenger Weight (lbs/M-ft) Allowed AWG or AWG or Ampacity Code Word* kcmils Stranding kcmils Stranding XLP PE XLP PE 6201 Alloy Neutral-Messenger Arabian 4 7 48.69 7 217 217 100 80 Belgian 2 7 77.47 7 328 328 135 105 Shetland 1/0 9 123.3 7 519 519 180 140 Thoroughbred 2/0 11 155.4 7 639 639 205 160 Walking 4/0 18 246.9 7 977 977 275 210 AAC Neutral-Messenger Pinto 4 7 4 7 211 211 100 80 Mustang 2 7 2 7 318 318 135 105 Criollo 1/0 9 1/0 7 506 503 180 140 Percheron 2/0 11 2/0 7 619 619 205 160 Oldenburg 4/0 18 4/0 19 945 945 275 210 Lippizaner 336.4 19 336.4 19 1,519 1,519 370 280 ACSR Neutral-Messenger Chola 6 7 6 6/1 153 153 75 60 Hackney 4 7 4 6/1 229 229 100 80 See referenced page in the Hardware & Supplies Palomino 2 7 2 6/1 347 347 135 105 section: Costena 1/0 9 1/0 6/1 549 549 180 140 Grullo 2/0 11 2/0 6/1 - 677 205 160 Suggested Prep Tool • Cable End Strippers Suffolk 3/0 17 3/0 6/1 837 837 235 185 2x2, 4x4 - I-9 Appaloosa 4/0 18 4/0 6/1 1,038 1,038 275 210 *Code word for XLP insulated products Bronco 336.4 19 336.4 18.1 1,568 1,568 370 280 are formed by adding /XLP to the con- Other cables not listed here may be available upon request. Information based on Southwire specs. ventional code word (e.g. Arabian/XLP).

6 www.ptsupply.com [email protected] 800-238-7514 Triplex 600V

Triplex 600V Secondary UD HI-SCORE Construction Conductors are stranded, compressed 1350-H16/H26 aluminum, insulated with an XLP meeting the requirements of ANSI/ICEA S-81-570. Neutrals are triple yellow extruded stripe. Cables with "YES" neutrals have sequential footage markers. Conductors are durably surface printed for identification. Two-phase conductors and one neutral conductor are cabled to produce the triplex cable configuration. Conductors are also available paralleled.

Specifications Meets or exceeds the following applicable ASTM specifications: • B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded • B-609 Aluminum 1350 Round Wire, Annealed and Intermidiate Tempers, for Electrical Purposes • B-786 19 Wire Combination Unilay-Stranded Aluminum Conductors for Subsequent Insulation • B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire HI-SCORE triplex or paralleled 600V secondary UD cable insulation meets or exceeds all grade and type require- ments of ANSI/ICEA S-81-570 and UL Standard 854 for Type USE-2.

Applications Used for secondary distribution and underground service at 600V or less, either direct burial or in ducts. Especially suited for applications requiring superior resistance to mechanical damage. Rated 90°C continuous operation, 130°C emergency overload and short circuit 250°C.

Phase Allowed Conductor Neutral Diameter (mils) Ampacity

AWG or AWG or Single Phase Neutral Complete Weight Direct In Code Word kcmils Stranding kcmils Stranding Conductor Cond. Cable (lbs/M-ft) Burial Ducts Vassar/HI-SCORE 4 7 4 7 345 345 745 192 125 90 Stephens/HI-SCORE 2 7 4 7 403 345 870 250 165 120 Ramapo/HI-SCORE 2 7 2 7 403 403 870 279 165 120 Brenau/HI-SCORE 1/0 9 2 7 512 403 1,106 387 215 160 Bergen/HI-SCORE 1/0 9 1/0 9 512 512 1,106 442 215 160 Converse/HI-SCORE 2/0 11 1 9 555 473 1,199 479 245 180 Hunter/HI-SCORE 2/0 11 2/0 11 555 555 1,199 535 245 180 Hollins/HI-SCORE 3/0 17 1/0 9 603 512 1,302 572 280 205 Sweetbriar/HI-SCORE 4/0 18 2/0 11 658 555 1,421 709 315 240 Monmouth/HI-SCORE 4/0 18 4/0 18 658 658 1,421 797 315 240 Pratt/HI-SCORE 250 26 3/0 17 732 603 1,581 856 345 265 Wesleyan/HI-SCORE 350 37 4/0 18 831 658 1,795 1,121 415 320 Newark/HI-SCORE 350 37 350 37 831 831 1,795 1,282 415 320 Rider/HI-SCORE 500 37 350 37 980 831 2,117 1,602 495 395 Fairfield/HI-SCORE 750 61 500 37 1,188 980 2,566 2,317 620 495 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

www.ptsupply.com 7 [email protected] 800-238-7514 15kV HI-DRI UD

15kV Primary UD Cable Construction The phase conductor is concentrically stranded, compressed soft or 1350-H16/26 aluminum alloy. The cable is composed of the conductor, cov- ered by a semi-conducting XLP strand shield, a tree-retardant XLP primary insulation and a semi-conducting XLP insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires is applied over the insulation shield. Specifications • B-231 Aluminum 1350 Conductors, Meets or exceeds the following applicable ASTM Concentric-Lay-Stranded specifications: • B-609 Aluminum 1350 Round Wire, Annealed and • B-3 Soft Annealed Copper Wire Intermediate Tempers, for Electrical Purposes • B-8 Concentric-Lay-Stranded Copper Conductors, Manufactured to the latest edition of the following Hard, Medium-Hard or Soft specifications and, in case of specification conflicts, • B-230 Aluminum, 1350-H19 Wire for Electrical in the order listed: ANSI/ICEA S-94-649, AEIC CS-8, Purposes RUS U-1. Applications Predominantly used for primary underground distribution; suitable for use in wet or dry locations, direct burial, underground duct and where exposed to sunlight. To be used at 15kV or less and at conductor temperatures not to exceed 90°C for normal operation. Phase Conductor Allowed Neutral Diameter (mils) Ampacity Size Comp. (AWG or No. of Bare Phase Over Over Insul. Comp. Cable Weight Direct In kcmils) Stranding Wires AWG Cond. Insul. Shield Cable (lbs/M-ft) Burial Ducts Aluminum Conductor, .175" insulation, 100% insulation level Call for specs on cable with copper conductor 2 7 10 14* 283 678 758 886 356 168* 119* 1/0 19 16 14* 362 758 838 966 496 218* 155* 2/0 19 20 14* 406 800 880 1,008 589 248* 177* 3/0 19 25 14* 456 850 930 1,058 703 284* 201* 4/0 19 20 12* 512 908 988 1,149 852 324* 230* 250 37 16 10* 558 963 1,043 1,246 1,020 360* 257* 350 37 18 14** 660 1,063 1,163 1,291 866 389** 319** 500 37 25 14** 789 1,193 1,293 1,421 1,142 468** 384** 750 61 24 12** 968 1,383 1,483 1,644 1,613 569** 468** 1,000 61 20 10 1,117 1,530 1,630 1,834 2,055 642 542 Aluminum Conductor, .22" insulation, 133% insulation level Call for specs on cable with copper conductor 2 7 10 14* 283 770 850 978 403 168 119* 1/0 19 16 14* 362 850 930 1,058 547 218 155* 2/0 19 20 14* 406 893 973 1,101 642 248 177* 3/0 19 25 14* 456 943 1,023 1,151 760 284 201* 4/0 19 20 12* 512 1,000 1,080 1,242 912 324 230* 250 37 16 10* 558 1,055 1,155 1,359 1,101 360 257* 350 37 18 14** 660 1,155 1,255 1,383 936 389 319** 500 37 25 14** 789 1,285 1,385 1,513 1,219 468 384** 750 61 24 12** 968 1,475 1,575 1,737 1,702 569 468** 1,000 61 20 10 1,117 1,623 1,753 1,956 2,193 642 542 *Full neutral construction (ampacities assume - single phase circuit, one cable). Information based on Southwire specs. **1/3 neutral cable (ampacities assume - three-phase circuit, three cables triplexed, multi-point grounding per ICEA methods).

8 www.ptsupply.com [email protected] 800-238-7514 25kV HI-DRI UD

25kV Primary UD Cable Construction The phase conductor is concentrically stranded, compressed soft copper or 1350-H16/26 aluminum alloy. The cable is composed of the conductor, covered by a semi-conducting XLP strand shield, a tree-retardant XLP pri- mary insulation and a semi-conducting XLP insulation shield. Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires is applied over the insulation shield. Specifications Meets or exceeds the following applicable ASTM specifications: • B-3 Soft Annealed Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft • B-230 Aluminum, 1350-H19 Wire for Electrical Purposes • B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded • B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes Manufactured to the latest edition of the following specifications and, in case of specification conflicts, in the order listed: ANSI/ICEA S-94-649, AEIC CS-8, RUS U-1

Applications Predominantly used for primary underground distribution; suitable for use in wet or dry locations, direct burial, underground duct and where exposed to sunlight. To be used at 25kV or less and at conductor temperatures not to exceed 90°C for normal operation.

Phase Allowed Conductor Neutral Diameter (mils) Ampacity

Size No. of Bare Phase Over Over Insul. Comp. Comp. Cable Weight Direct In (AWG or kcmils) Stranding Wires AWG Cond. Insul. Shield Cable (lbs/M-ft) Burial Ducts Aluminum Conductor, .26" insulation, 100% insulation level 1 19 13 14* 322 880 960 1,088 513 189* 134* 1/0 19 16 14* 362 920 1,000 1,128 590 214* 152* 2/0 19 20 14* 406 965 1,045 1,173 688 243* 173* 3/0 19 25 14* 456 1,015 1,095 1,223 808 278* 197* 4/0 19 20 12* 512 1,070 1,170 1,332 979 318* 225* 250 37 16 10* 558 1,125 1,225 1,429 1,153 353* 252* 350 37 18 14** 660 1,228 1,328 1,456 994 387** 320** 500 37 25 14** 789 1,358 1,458 1,586 1,284 466** 386** 750 61 24 12** 968 1,545 1,645 1,807 1,773 567** 475** Copper Conduct, .26" insulation, 100% insulation level 1 19 20 14* 322 880 960 1,686 801 235* 168* 1/0 19 25 14* 362 920 1,000 1,128 937 268* 190* 2/0 19 20 12* 405 965 1,045 1,207 1,130 307* 220* 3/0 19 25 12* 456 1,015 1,095 1,257 1,363 351* 250* 4/0 19 20 10* 512 1,070 1,170 1,374 1,682 402* 287* 250 37 24 10* 558 1,125 1,225 1,429 1,959 445* 317* 350 37 18 12** 661 1,230 1,330 1,492 1,890 487** 403** 500 37 26 12** 790 1,358 1,458 1,619 2,575 575** 475** *Full neutral construction (ampacities assume - single phase circuit, one cable). Information based on Southwire specs. **1/3 neutral cable (ampacities assume - three-phase circuit, three cables triplexed, multi-point grounding per ICEA methods).

www.ptsupply.com 9 [email protected] 800-238-7514 Bare Copper

Bare Copper Conductors Construction Bare copper, solid or stranded. Available in tempers hard, medium-hard, or soft. Stranded conductors are concentrically stranded in hard and medium-hard tempers and are Combination Unilay stranded in the soft-drawn temper.

Specifications Meets or exceeds the following applicable ASTM specifications: • B-1 Hard-Drawn Copper Wire • B-2 Medium-Hard Copper Wire • B-3 Soft or Annealed Copper Wire • B-787 19 Wire Combination Unilay-Stranded Soft Copper Wire • B-8 Concentric-Lay-Stranded Hard, Medium-Hard or Soft Copper Conductor

Applications Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers and grounds in electrical construction. Soft drawn copper is unilay construction.

DC Resistance (Ohms/M-ft @ 20˚C)

Weight Diameter Medium Soft Drawn Allowable AWG (lbs/M-ft) (mils) Hard Drawn Hard Drawn (Annealed) Ampacity Solid 14 12.4 64.1 2.626 2.613 2.525 - 12 19.8 80.8 1.652 1.643 1.588 - 10 31.4 101.9 1.039 1.033 .999 - 8 50 128.5 .653 .650 .628 95 6 79.4 162 .411 .409 .395 125 Other cables not listed here 4 126.3 204.3 .258 .257 .249 170 may be available upon request.

2 200.9 257.6 .163 .162 .156 225 Information based on Southwire specs. Other cables not listed here may be available upon request. DC Resistance Diameter (in) (Ohms/M-ft @ 20˚C) Size (AWG or Stranding Weight Indv. Complete Medium Soft Drawn Allowable kcmils) Stranding Class (lbs/M-ft) Wires Cables Hard Drawn Hard Drawn (Annealed) Ampacity Stranded 8 7 B 51 49 146 .66630 .66290 .64080 95 6 7 B 81 61 184 .41910 .41690 .40300 130 4 7 A, B 128.9 77 232 .26360 .26220 .25340 170 2 7 A, B 204.9 97 292 .16600 .16500 .15780 230 1/0 7 A, AA 326.1 123 368 .10420 .10370 .10020 310 2/0 7 A, AA 410.9 138 414 .08627 .08224 .07949 355 3/0 7 A, AA 518.1 155 464 .06556 .06522 .06304 410 4/0 7 A, AA 653.3 174 522 .05199 .05172 .04999 480 4/0 19 B 653.3 106 528 .05199 .05172 .04999 480 250 19 A 771.9 115 574 .04400 .04378 .04231 530 350 19 A 1080.6 136 679 .03143 .03127 .03022 650 500 37 A, B 1543.8 116 814 .02200 .02189 .02116 810

10 www.ptsupply.com [email protected] 800-238-7514 Covered Line Wire, Copper

Covered Line Wire Copper Conductor Construction Conductors are hard or medium-hard concentrically stranded copper. Covered with black PE or XLP.

Specifications Meets or exceeds the following ASTM specifications: • B-1 Hard-Drawn Copper Wire • B-3 Medium Hard-Drawn Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft Meets all applicable requirements of ANSI/ICEA S-70-547.

Applications Used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as a bare conductor.

Size (AWG O.D. Weight DC Resistance Allowable or kcmils) Stranding Covered (mils) (lbs/M-ft) (ohms/M-ft @ 20˚C) Ampacity Solid 6 1 222 86.7 .411 130 4 1 264 135.3 .258 170 3 1 319 174.9 .205 195 2 1 348 218.1 .163 225 Stranded 6 7 238 90.3 .503 130 4 7 285 140.8 .316 175 2 7 373 227.1 .199 230 1/0 7 477 363.3 .125 305 2/0 7 522 453.3 .0992 350 3/0 7 570 565.6 .0788 405 4/0 7 626 707.6 .0625 465 250 19 677 825.4 .0530 520 300 19 729 984.6 .0442 580 350 19 779 1,144.5 .0380 640 500 37 950 1,637.2 .0278 785 750 61 1,128 2,422.8 .0182 995 1,000 61 1,307 3,234 .0140 1,180

Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

www.ptsupply.com 11 [email protected] 800-238-7514 Transformer Riser Wire

Transformer Riser Wire Construction Conductors are solid or stranded soft copper. Stranded conductors are concentrically stranded, compressed. The covering is high molecular weight PE, black.

Specifications Meets or exceeds the following ASTM specifications: • B-3 Soft or Annealed Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft Applications Used as uninsulated transformer risers at voltages up to and includ- ing 13.2kV. Although not treated as an insulation, the covering on transformer riser wire does reduce faults due to atmospheric conditions, shorts caused by excessive vibrations and faulting caused by objects crossing the leads.

Diameter (mils) Weight AWG Stranding Bare Covered (lbs/M-ft) 8 Solid 128.5 348.5 83 6 Solid 162 382 117 4 Solid 204.3 424.3 170 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

12 www.ptsupply.com [email protected] 800-238-7514 Type MV-90

5kV, 5kVU Type MV-90 Copper XLP, TS, PVC Conductors Conductor Construction Shield Single conductor XLP insulated, shielded, thermoplastic jacket . Proven XLP insulation, 90°C continuous conductor operating temperature, 100% XLP Insulation copper tape shield coverage, fast stripping thermosetting insulation shield and it is triple extruded. Cable is sunlight resistant, suitable for direct burial. Also available listed for cable tray use in sizes 250 kcmils and larger upon request. Insulation Shield

Specifications Copper Tape Manufactured and tested in accordance with the latest revisions of the following Shield standards and specification: • UL 1072 - Medium Power Cables PVC Jacket • ICEA S-93-639 (NEMA WC 74) - 5-46 kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

Applications For use in aerial, direct burial, conduit, and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal opera- tion, 130°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 5kV, 100% (grounded system) and 133% insulation level (ungrounded system).

Allowable Ampacity Mininum Approx. Size (AWG Conductor Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 4 .225 .055 .654 309 110 97 2 .283 .055 .709 406 145 130 1 .322 .055 .749 474 170 155 1/0 .362 .055 .789 557 195 180 2/0 .405 .070 .860 681 220 205 3/0 .456 .070 .910 809 250 240 4/0 .512 .070 .965 968 290 280 250 .558 .070 1.020 1,108 320 315 350 .661 .070 1.125 1,462 385 385 500 .790 .070 1.250 1,977 470 475 750 .968 .070 1.437 2,826 585 600 1,000 1.117 .070 1.582 3,654 670 690 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 5 End Stripper - I-9

www.ptsupply.com 13 [email protected] 800-238-7514 Type MV-90

15kV Type MV-90 Copper Conductors XLP, TS, PVC Conductor Construction Shield Single conductor XLP insulated, shielded, thermoplastic jacket power cable. XLP Insulation Proven XLP insulation, 90°C continuous conductor operating temperature, 100% copper tape shield coverage, fast stripping thermosetting insulation shield and it is triple extruded. Cable is sunlight resistant, suitable for direct burial. Also Insulation available listed for cable tray use in sizes 250 kcmils and larger upon request. Shield Copper Tape Specifications Shield Manufactured and tested in accordance with the latest revisions of the following standards and specification: PVC Jacket • UL 1072 - Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC 74) - 5-46 kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

Applications For use in aerial, direct burial, conduit and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal opera- tion, 130°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 15kV, 100% insulation level (grounded system).

Allowable Ampacity (amps) Mininum Approx. Size (AWG Conductor Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 2 .283 .07 .905 531 155 150 1 .322 .07 .945 603 175 170 1/0 .362 .07 .985 692 200 195 2/0 .405 .07 1.025 797 230 225 3/0 .456 .07 1.075 930 260 260 4/0 .512 .07 1.130 1,095 295 295 250 .558 .07 1.185 1,241 325 330 350 .661 .07 1.290 1,605 390 395 500 .790 .07 1.415 2,132 65 480 750 .968 .07 1.602 3,002 565 585 1,000 1.117 .10 1.810 3,948 640 675 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 5 End Stripper - I-9

14 www.ptsupply.com [email protected] 800-238-7514 Type MV-90

5kV, 5kVU Type MV-90 Copper XLP, WS, PVC Conductors Conductor Construction Shield Single conductor XLP insulated, shielded, thermoplastic jacket power cable. Proven XLP insulation, 90°C continuous conductor operating temperature, fast stripping XLP Insulation thermosetting insulation shield and it is triple extruded. Cable is sunlight resistant, Insulation suitable for direct burial. Shield Binder Tape Specifications Manufactured and tested in accordance with the latest revisions of the following Copper Wire Shield standards and specification: • UL 1072 - Medium Voltage Power Cables PVC Jacket • ICEA S-93-639 (NEMA WC 74) - 5-46kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

Applications For use in aerial, direct burial, conduit and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal opera- tion, 130°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 5kV, 100% (grounded system) and 133% insulation level (ungrounded system).

Allowable Ampacity (amps) Mininum Approx. Size (AWG Conductor Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 1 .322 .055 .777 442 170 155 1/0 .362 .07 .848 546 195 180 2/0 .405 .07 .888 646 220 205 3/0 .456 .07 .938 772 250 240 4/0 .512 .07 .993 926 290 280 250 .558 .07 1.048 1,065 320 315 350 .661 .07 1.153 1,412 385 385 500 .790 .07 1.278 1,920 470 475 750 .968 .07 1.465 2,759 585 600 1,000 1.117 .07 1.610 3,579 670 690 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 5 End Stripper - I-9

www.ptsupply.com 15 [email protected] 800-238-7514 Type MV-90

15kV Type MV-90 Copper XLP, WS, PVC Conductors Conductor Construction Shield Single conductor XLP insulated, shielded, thermoplastic jacket power cable. Proven XLP Insulation XLP insulation, 90°C continuous conductor operating temperature, fast-stripping thermosetting insulation shield and it is triple extruded. Cable is sunlight resistant, Insulation suitable for direct burial. Shield Binder Tape Specifications Copper Wire Manufactured and tested in accordance with the latest revisions of the following Shield standards and specification: • UL 1072 - Medium Voltage Power Cables PVC Jacket • ICEA S-93-639 (NEMA WC 74) - 5-46 kV Shielded Power Cable for Use in Transmission & Distribution of Electric Energy Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

Applications For use in aerial, direct burial, conduit and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal opera- tion, 130°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 15kV, 100% insulation level (grounded system).

Allowable Ampacity Minimum Approx. Size (AWG Conductor Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 2 .283 .07 .933 494 155 150 1 .322 .07 .973 563 175 170 1/0 .362 .07 1.013 651 200 195 2/0 .405 .07 1.053 753 230 225 3/0 .456 .07 1.103 884 260 260 4/0 .512 .07 1.170 1,119 295 295 250 .558 .07 1.225 1,266 325 330 350 .661 .07 1.330 1,633 390 395 500 .790 .07 1.455 2,162 465 480 750 .968 .07 1.642 3,034 565 585 1,000 1.117 .10 1.850 3,985 640 675

Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool WS 5 End Stripper - I-9

16 www.ptsupply.com [email protected] 800-238-7514 Type MV-90

2.4kV Type MV-90 Copper EPR Heavy Wall, N/S Conductors Conductor Construction Shield Single conductor EPR insulated, PVC jacket power cable. Flexible, easy bending EPR Insulation insulation, easy cable preparation, 90°C continuous operating temperature, resistance to moisture. Flame-retardant. Also available listed for cable tray use in sizes 1/0 and larger.

Specifications PVC Jacket Manufactured and tested in accordance with the latest revisions of the following standards and specification: • UL 1072 - Medium Voltage Power Cables • ICEA S-96-659 (NEMA WC 71) - Unshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electric Energy

Applications For use primarily in raceways in industrial applications as specified by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload condi- tions and 250°C for short circuit conditions and are rated at 2.4kV in wet or dry locations. Allowable Ampacity Approx. Size (AWG Conductor Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 6 .178 .080 .645 253 85 75 4 .225 .080 .692 321 110 97 2 .283 .080 .750 422 145 130 1 .322 .080 .789 489 170 155 1/0 .362 .080 .829 574 195 180 2/0 .405 .080 .871 676 220 205 3/0 .456 .095 .954 834 250 240 4/0 .512 .095 1.010 995 290 280 250 .558 .110 1.127 1,199 320 315 350 .661 .110 1.229 1,560 385 385 500 .790 .110 1.357 2,088 470 475 750 .968 .125 1.608 3,044 585 600 1,000 1.117 .125 1.756 3,897 670 690

Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 5 End Stripper - I-9

www.ptsupply.com 17 [email protected] 800-238-7514 Type MV-105

5kVU, 8kV Type MV-105 Copper Conductors TS, PVC, CT Rated Conductor Shield Construction Single conductor EPR insulated, shielded, thermoplastic jacketed power EPR cable. Flexible, easy bending insulation, easy cable preparation, fast strip- Insulation ping thermosetting insulation shield, 105°C continuous operating tem- perature, 100% shield coverage and it is triple extruded. Cable is sunlight Insulation resistant, suitable for direct burial and listed for cable tray use in sizes 1/0 Shield and larger. Copper Tape Shield Specifications Manufactured and tested in accordance with the latest revisions of the PVC Jacket following standards and specifications: • UL 1072 - Medium Voltage Power Cables • ICEA S-93-639 (NEMA WC 74) - 5-46 kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy • ICEA S-97-682 (when requested) 5-46 kV Standard for Utility Shielded Power Cable • UL 1685 - (AWG 1/0 and larger) -UL Flame Exposure Test • IEEE 1202 - Flame Test (70,000 Btu/hr Vertical Tray Test) Certified qualification tests were performed in accordance with the requirements of ICEA CS-6. Cable has fully met the qualification testing requirements of ICEA CS-6.

Applications For use in aerial, direct burial, cable trays, conduit and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 5kV, 133% (ungrounded system) and 8kV 100% insulation level (grounded system).

Allowable Ampacity Approx. Size (AWG Conductor Min. Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 6 .178 .055 .656 282 92 84 4 .225 .055 .701 351 120 110 1 .322 .055 .799 525 180 175 1/0 .362 .070 .870 641 210 200 2/0 .405 .070 .910 745 235 225 3/0 .456 .070 .960 877 270 270 4/0 .512 .070 1.015 1,036 310 305 250 .558 .070 1.070 1,181 345 355 350 .661 .070 1.175 1,543 415 430 500 .790 .070 1.300 2,067 505 530 750 .968 .070 1.487 2,932 630 665 1,000 1.117 .070 1.632 3,771 720 770 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 5 End Stripper - I-9

18 www.ptsupply.com [email protected] 800-238-7514 Type MV-105

Copper 5kV, 5kVU Type MV-105 Conductors

TS, GW, PVC, CT Rated Conductor Shield Construction EPR Insulation Three conductor EPR insulated, shielded, thermoplastic jacketed power cables with grounding conductor. Alternate constructions available. Copper Tape Shield Insulation Shield

Specifications Ground Conductor Manufactured and tested in accordance with the latest revisions of the Fillers following standards and specifications: • UL 1072 - Medium Voltage Power Cables Core Binder Tape • ICEA S-93-639 (NEMA WC 74) - 5-46 kV Shielded Power Cable for use in the Transmission & Distribution of Electric Energy PVC Jacket • ICEA S-97-682 (when requested) 5-46 kV Standard for Utility Shielded Power Cable • UL 1685 - UL Flame Exposure Test • IEEE 1202 (Sizes 4 AWG and larger) - Flame Test (70,000 Btu/hr Vertical Tray Test) Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

Applications For use in aerial installations, direct buried, cable trays, troughs or raceway. These cables are capable of operating continuously at a maximum conductor temperature of 105°C for normal operation, 140°C for emergency overload conditions and 250°C for short circuit conditions and are rated at 5kV, 100% (grounded system) and 133% insulation levels (ungrounded system).

Allowable Ampacity (amps) Ground Approx. Size (AWG Conductor Conductor Min. Point Jacket Approx. Overall Net Weight Conduit or kcmils) Diameter (in) (AWG) Thickness (in) Diameter (in) (lbs/M-ft) Duct in Air 2 .283 6 .070 1.443 1,447 145 135 1 .322 4 .070 1.529 1,730 165 155 1/0 .362 4 .070 1.616 1,987 190 185 2/0 .405 4 .100 1.765 2,421 220 210 3/0 .456 3 .100 1.873 2,869 250 245 4/0 .512 3 .100 1.992 3,384 285 285 250 .558 3 .100 2.123 3,868 315 315 350 .661 2 .100 2.349 5,056 380 390 500 .790 1 .100 2.619 6,770 460 475 750 .968 1/0 .125 3.077 9,722 570 585 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool WS 5 End Stripper - I-9

www.ptsupply.com 19 [email protected] 800-238-7514 Type TC

Type TC Power Cable Copper 600V THHN/PVC, GW Conductors PVC Insulation Construction with Nylon Available in sizes 8 AWG through 750 kcmils and is manufactured using Type Jacket THHN or THWN conductors. Individual conductors are bare annealed copper covered with a PVC insulation over which a nylon (polyamide) or UL listed equal Ground Conductor jacket is applied. The overall jacket consists of a flame- retardant, moisture- and sunlight-resistant PVC jacket. Non-halogen jacket available upon request. Ground Conductor Specifications Meets or exceeds the applicable requirements of the following standards and PVC Jacket specifications: • ASTM - (All applicable standards) • UL 1277 - Electrical Power and Control Tray Cables • UL 1581 - Electrical Wires, Cables and Flexible Cords • ICEA S-58-679 - Control Cable Conductor Identification. (Method 4 - single color compounds with surface printing of numbers) • UL 1685 - UL Flame Exposure Test (70,000 Btu/hr) • ICEA T-29-520 - Vertical Cable Tray Flame Test (210,000 Btu/hr) • IEEE 1202 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 Bth/hr)

Applications Used to supply power to motors or for connection to other power devices in industrial settings. Primary installa- tions include cable trays, raceways and outdoor locations where supported by a messenger wire. Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. This cable may be used at temperatures not to exceed 75°C in wet locations and 90°C in dry locations. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC® 336.10.

Ground Ampacity Size (AWG Conductor Average Overall Approx. Weight or kcmils) Stranding (AWG) Diameter (in) (lbs/M-ft) 75˚C 90˚C 8 7 10 .625 295 50 55 6 7 8 .710 433 65 75 4 7 8 .795 605 85 95 2 7 6 .958 940 115 130 1 19 6 1.100 1,193 130 150 1/0 19 6 1.184 1,442 150 170 2/0 19 6 1.281 1,730 175 195 3/0 19 4 1.391 2,159 200 225 4/0 19 4 1.508 2,613 230 260 250 37 4 1.659 3,065 255 290 350 37 3 1.942 4,270 310 350 See referenced page in the 500 37 2 2.220 5,899 380 430 Hardware & Supplies section: 750 61 1 2.652 8,600 475 535 Information based on Southwire specs. Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

20 www.ptsupply.com [email protected] 800-238-7514 Type TC

Type TC Composite Cable Stranded Bare Copper 600V, TFFN or VW-1 THHN/THWN High Dielectric Strength PVC Construction Insulation Multiconductor cables have TFFN or VW-1 THHN/THWN (PVC/Nylon) Conductor Jacket conductors with an overall gas/vapor-tight PVC jacket. Three power conductors and four or six control conductors. Tape Binder Specifications (optional) Conforms to the following standards and specifications: • NEC® Article 392 Cable Trays and 336 Power and Control Cable Type TC • Standard 1277 of Underwriters Laboratories, Inc. PVC Jacket • ICEA T-30-520 - Flame Test Note: Stranding is • ICEA T-29-520 - Vertical Cable Tray Flame Test (210,000 Btu/hr) Class B, 2-14 AWG • IEEE-383 - 70,000 BTU Cable Tray Propagation Test • IEEE 1202 - 70,000 BTU Flame Tests • CSA FT4 • UL E60749

Applications For supplying power and control signals to motors or providing connection to other power devices utilizing remote control circuits. Specifically approved for direct burial, wet or dry locations and outdoors in cable trays where a sunlight-resistant rating is required. UL Listed and OSHA acceptable. Recognized for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit.

Power Conductors Control Conductors

No. of No. of Overall Jacket Approx. Approx. Weight Conductors AWG Conductors AWG Thickness (mils) O.D. (in) (lbs/M-ft) 3 12 4 14 45 .470 192 3 10 4 14 45 .515 265 3 8 4 14 60 .650 356 3 6 4 14 60 .715 458 3 4 4 14 80 .880 702 3 2 4 14 80 1.005 982 Information based on AIW specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

www.ptsupply.com 21 [email protected] 800-238-7514 Type TC

Type TC Power Cable Copper Conductors 600V, XHHW/PVC, GW Construction PVC Insulation with Nylon Available in sizes 8 AWG through 750 kcmils and is manufactured using Type Jacket XHHW-2 conductors. Individual conductors are bare annealed copper covered with XLP insulation. The overall jacket consists of a flame-retardant, moisture- and Ground sunlight-resistant PVC jacket. Non-halogen jacket available upon request. Conductor Binder String Specifications Filler Meets or exceeds the applicable requirements of the following standards and PVC Jacket specifications: • ASTM - (All applicable standards) • UL 44 • UL 1277 - Electrical Power and Control Tray Cables. UL 1581 - Electrical Wires, Cables and Flexible Cords • ICEA S-58-679 - Control Cable Conductor Identification. (Method 4 - single color (black) compounds with surface printing of numbers) • UL 1685 - Flame Exposure Test (70,000 Btu/hr) • ICEA T-29-520 - Vertical Cable Tray Flame Test (210,000 Btu/hr) • IEEE 1202 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 Bth/hr) Meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) - Unshielded 0 - 2 kV Cables, with testing frequencies based on UL requirements.

Applications For supplying power to motors or for connection to other power devices in industrial settings. Primary installa- tions include cable trays, raceways and outdoor locations where supported by a messenger wire. Type TC Power Cable is listed for direct burial or in underground ducts and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. This cable may be used in wet and dry locations at temperatures not to exceed 90°C. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC® 336.10°C.

Ground Size (AWG Conductor Average Overall Approx. Weight Ampacity or kcmils) Stranding (AWG) Diameter (in) (lbs/M-ft) 90˚C 8 7 10 .681 330 55 6 7 8 .766 468 75 4 7 8 .797 606 95 2 7 6 .960 954 130 1 19 6 1.100 1,173 150 1/0 19 6 1.186 1,421 170 2/0 19 6 1.279 1,704 195 3/0 19 4 1.385 2,135 225 4/0 19 4 1.506 2,580 260 250 37 4 1.653 3,021 290 See referenced page in the 300 37 3 1.827 3,684 320 Hardware & Supplies section: 350 37 3 1.935 4,219 350 Suggested Prep Tool 400 37 3 2.032 4,747 380 • Cable End Strippers 500 37 2 2.214 5,838 430 2x2, 4x4 - I-9 750 61 1 2.663 8,543 535 Information based on Southwire specs.

22 www.ptsupply.com [email protected] 800-238-7514 RHH/RHW

RHH/RHW Power Cable 600V CT Rated Construction RHH or RHW-2 or USE-2 copper conductors are annealed (soft) copper. Insulation is an abrasion-, moisture-, heat-resistant and flame-retardant XLP. This product is sunlight resistant and rated for cable tray use.

Specifications Meets or exceeds the applicable requirements of the following standards and specifications: • UL 44 - Thermoset-Insulated Wires and Cables • UL 1581 - UL Flame Exposure Test (VW-1) • UL 854 - Service Entrance Cables • UL 1685 - UL Flame Exposure Test • ICEA S-95-658 (NEMA WC70) Unshielded Power Cables 2000 Volts or Less for the Distribution of Electrical Energy • IEEE 1202 Flame Test (4/0 and Larger) Type RHH or RHW-2 or USE-2 meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) - Unshielded 0 - 2kV cables, with testing frequencies based on UL requirements.

Applications For use in conduit or cable tray as specified in the NEC®. When used as Type USE-2 conductor is suitable for use as underground service entrance cable for direct burial at conductor temperatures not to exceed 90°C. When used as RHH or RHW-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHH or RHW-2 or USE-2 conduc- tors is 600V.

Allowable Ampacities (amps) Size (AWG No. of Approx. Overall Approx. Weight or kcmils) Strands Diameter (in) (lbs/M-ft) Conduit Free Air 1/0 19 .525 390 170 260 2/0 19 .568 481 195 300 3/0 19 .619 597 225 350 4/0 19 .675 741 260 405 250 37 .751 880 290 455 350 37 .854 1,207 350 570 500 37 .983 1,693 430 700 750 61 1.191 2,516 535 885 1,000 61 1.340 3,315 615 1,055 Information based on Southwire specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

www.ptsupply.com 23 [email protected] 800-238-7514 Cable

Welding Cable Class K (#30) Rope Lay 105˚C, Black Stranding

Construction Separator Bare, annealed copper per ASTM B-3. 30 AWG rope lay stranded per ASTM B-172. Jacket is black thermoset EPDM. 105°C to -55°C. RoHS compliant.

Applications Thermoset Designed for welding cable use where resistance to cuts, tears and Insulation abrasion is required.

Size (AWG Shipping Weight or kcmils) Stranding Nominal O.D. (in) Amps* (lbs/M-ft) 6 259 x 30 .320 115 125 4 413 x 30 .375 150 182 2 651 x 30 .440 205 271 1 826 x 30 .505 240 360 1/0 1,044 x 30 .570 285 444 2/0 1,308 x 30 .605 325 535 3/0 1,653 x 30 .670 380 667 4/0 2,071 x 30 .720 440 809 *Ampacity ratings are based on cable in free air at 30˚C. Ampacities will be greater when used for intermittent welding applications. Information based on AIW specs.

90˚C, Orange Construction Bare, annealed copper per ASTM B-3. 34 AWG rope lay stranded per ASTM B-172 (Class M #34 stranding). Jacket is oil-resistant, thermoset CPE per ASTM D-4313. Rated 90°C to -55°C.

Applications Designed for welding cable use where resistance to cuts, tears and abra- sion is required.

Size (AWG Shipping Weight or kcmils) Stranding Nominal O.D. (in) Amps* (lbs/M-ft) 6 665 x 34 .395 105 134 4 1,045 x 34 .450 140 191 2 1,650 x 34 .515 190 286 1 2,090 x 34 .545 220 350 1/0 2,640 x 34 .600 260 454 2/0 3,300 x 34 .685 300 530 3/0 4,180 x 34 .755 350 658 4/0 5,225 x 34 .825 405 839 *Ampacity ratings are based on cable in free air at 30˚C. Ampacities will be greater when used for intermittent welding applications.

Information based on AIW specs.

24 www.ptsupply.com [email protected] 800-238-7514 Type SOOW

Type SOOW Cable Flexible Bunch Stranded Bare Copper Conductors 90°C, 600V Synthetic Rubber Construction Insulation (EPDM) Stranded bare copper, EPR insulation, suitable fillers, separator, oil- and weather-resistant, black CPE jacket.

Specifications Separator Meets or exceeds all applicable requirements of: • UL 62 (Flexible Cord and Fixture Wire) • CSA Standard 22.2 No. 49 (Flexible Cords and Cables) Thermoset • Mine Safety and Health Administration (MSHA) flame resistance for CPE Jacket Mining Applications This product complies with the requirements of Federal and Military Specification JC-580B, NEC® Article 400 and is OSHA acceptable.

Applications Permitted for use as specified by Article 400 and related articles of the NEC®. Some typical applications for Type SOOW Cords include wiring for industrial machinery, motors and associated equipment, portable tools and equipment, and temporary electrical power and lighting installations for construction sites. Type SOOW Cords are suitable for use in (i) dry locations not to exceed minimum -40°C or maximum 90°C or (ii) wet locations or other applicable locations. When exposed to oil or coolant at temperatures not to exceed 60°C. Type SOOW cords are ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential.

Nom. Nom. Nominal Insul. Overall Weight Nominal Insul. Overall Weight AWG Stranding Thickness (mils) Dia. (mils) (lbs/M-ft) Ampacity AWG Stranding Thickness (mils) Dia. (mils) (lbs/M-ft) Ampacity 18/2 16 x 30 30 345 70 10 8/2* 65 x 26 50 660 290 40 18/3 16 x 30 30 365 80 7 8/3* 65 x 26 50 720 365 35 18/4 16 x 30 30 390 95 5.6 8/4* 65 x 26 50 780 500 28 16/2 26 x 30 30 370 80 13 8/5* 65 x 26 50 860 545 28 16/3 26 x 30 30 390 95 10 6/3* 101 x 26 50 800 515 45 16/4 26 x 30 30 420 115 8 6/4* 101 x 26 50 845 620 36 14/2 41 x 30 45 510 135 18 6/5* 101 x 26 50 945 750 36 14/3 41 x 30 45 535 170 15 4/2* 119 x 25 50 890 500 70 14/4 41 x 30 45 575 205 12 4/3* 119 x 25 50 940 670 60 12/2 65 x 30 45 570 195 25 4/4* 119 x 25 50 1,010 835 48 12/3 65 x 30 45 595 225 20 4/5* 119 x 25 50 1,135 1,065 48 12/4 65 x 30 45 650 270 16 2/3* 133 x .0211 55 1,090 1,030 80 10/2 104 x 30 45 620 250 30 2/4* 133 x .0211 55 1,170 1,285 64 10/3 104 x 30 45 660 290 25 2/5* 133 x .0211 55 1,435 1,620 64 10/4 104 x 30 45 715 355 20 Information based on AIW specs. ® *Not UL or CSA, but manufactured to acceptable commercial standards. For SDN Flexible Control 2-8 AWG are non-UL and non-CSA, but the option is available. Cable see page 16 in the Instrumentation & Tray section

See referenced pages in the Hardware & Supplies section Suggested Prep Tools • Cable End Strippers 2x2, 4x4 - I-9 • MKO1A Jacket Stripper - I-11 • 721 Multi-Wire Stripper/Cutter - I-9

www.ptsupply.com 25 [email protected] 800-238-7514 Type SOW

Type SOW Stranded Copper Industrial Motor Lead Cable Conductor

90°C, 600V EPDM Insulation Construction Stranded, annealed bare copper conductor, EPDM insulation, heavy-duty, oil-resistant thermoset jacket.

Applications Thermoset Designed for use as motor and power leads where flexibility and Jacket portability are required.

Insulation Jacket Shipping Weight AWG Stranding Conductor O.D. (in) Thickness (in) Thickness (in) Nominal O.D. (in) Amps (lbs/M-ft) 16 26 x .01 .060 .030 .03 .186 13 25 14 41 x .01 .075 .045 .03 .233 18 48 12 65 x .01 .095 .045 .03 .253 25 51 10 104 x .01 .120 .045 .03 .278 30 66 Information based on AIW specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • Cable End Strippers 2x2, 4x4 - I-9

For SDN® Flexible Control Cable see page 16 in the Instrumentation & Tray section

26 www.ptsupply.com [email protected] 800-238-7514 Industrial Grade Cable

Type G & G-GC Round 90°C, 2kV & 600V/2kV Construction Manufactured with rope-lay stranded, bunched members, annealed copper conductors which are insulated with a premium-grade EPDM. The three or four insulated conductors are assembled round with non-wicking rubber fillers as needed and are covered with a black jacket rated -40°C - 90°C (90°C dry locations, 75°C wet locations). See referenced pages in the Hardware & Supplies section: Specifications Suggested Prep Tools • UL Listed • RoHS compliant • MK01A Jacket Stripper - I-11 • CSA and MSHA approved • Meets FT-5 Flame Test MK04 Jacket Stripper - I-11 • Applications For use in industrial and light- to medium-duty mining applications, heavy-duty service as power supply cable, power cable for mobile and portable electrical equipment at continuous conductor temperature of 90°C. Type G cables are suitable for use on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. Excellent flexibility, resistance to oils, solvents, ozone, aging and abrasion.

Size (AWG Cond. Ground Ground Nom. Insulation Nominal Current Approx. Net or kcmils) Strand Check AWG Cond. AWG Thick. (in) O.D. (in) Amps Weight (lbs/M-ft) 3 Conductor Type G-GC 2kV 8 133 10 2#10 .060 .965 65 665 6 259 10 2#10 .060 1.050 87 830 4 259 10 2#8 .060 1.105 114 1,145 2 259 10 2#7 .080 1.300 152 1,485 1 259 8 2#6 .080 1.465 177 2,100 1/0 259 8 2#5 .080 1.605 205 2,550 2/0 259 8 2#4 .080 1.750 237 3,020 3/0 259 8 2#3 .080 1.860 274 3,660 4/0 259 8 2#2 .080 1.940 316 4,410 250 627 8 2#2 .095 2.390 352 6,060 350 855 8 2#1/0 .095 2.680 433 7,400 500 1,235 8 2#2/0 .095 3.030 536 10,100 4 Conductor Type G 600V/2kV 8 133 4#12 - .060 1.045 52 635 6 259 4#12 - .060 1.125 70 900 4 259 4#10 - .060 1.210 91 1, 280 2 259 4#9 - .080 1.435 122 2,000 1 259 4#8 - .080 1.650 142 2,660 1/0 259 4#7 - .080 1.720 164 3,140 2/0 259 4#6 - .080 1.860 190 3,780 3/0 259 4#5 - .080 2.075 219 4,500 4/0 259 4#4 - .080 2.155 253 5,520 Color Coding: Information based on Southwire specs. 3-conductor White/Black/Red 4-conductor White/Black/Red/Orange

www.ptsupply.com 27 [email protected] 800-238-7514 Industrial Grade Cable

Bare Copper Mine Power Feeder Cable Conductors Conductor Shield 90°C, 5kV/8kV/15kV XLP Insulation Construction Insulation Shield Insulated Bare stranded copper, extruded semi-conductor shield, XLP insulation, Ground Check extruded insulation shield, ground and ground check conductors, jute Uninsulated Ground Wire fillers, cable reinforcement and black PVC jacket. Open Reinforcement Specifications • UL Listed • Passes MSHA Flame Test • OSHA and MSHA acceptable • Meets ICEA requirements PVC Jacket

Applications For use in high-voltage distribution circuits for permanent or semi-portable installations in bore holes, shafts, open pits, strip mines and tunnels. Ground Power Conductor Grounding Check Conductors AWG or No. of Insulation Insulation Nominal Approx. Ship. kcmils Strands Thickness (in) AWG Strands AWG Thickness (in) O.D.(in) Amps Weight (lbs/M-ft) 5kV - 100% & 133% Insulation Level - ES-13139 6 7 .09 10 7 x .0385 10 .030 1.235 93 991 4 7 .09 8 7 x .0486 8 .045 1.320 122 1,197 2 7 .09 6 7 x .0612 8 .045 1.460 159 1,653 2/0 19 .09 3 7 x .0867 8 .045 1.690 243 2,591 4/0 19 .09 1 19 x .0664 8 .045 1.950 321 3,806 250 37 .09 1/0 19 x .0745 8 .045 2.075 355 4,660 350 37 .09 2/0 19 x .0837 8 .045 2.285 435 6,130 500 37 .09 4/0 19 x .1055 8 .045 2.550 536 8,240 8kV - 100% Insulation Level - ES-13140 6 7 .115 10 7 x .0385 10 .030 1.350 93 1,077 4 7 .115 8 7 x .0486 8 .045 1.445 122 1,290 2 7 .115 6 7 x .0612 8 .045 1.565 159 1,710 1 19 .115 5 7 x .0688 8 .045 1.630 184 1,996 2/0 19 .115 3 7 x .0867 8 .045 1.850 243 2,857 4/0 19 .115 1 19 x .0664 8 .045 2.070 321 3,946 250 37 .115 1/0 19 x .0745 8 .045 2.190 355 4,980 350 37 .115 2/0 19 x .0837 8 .045 2.400 435 6,280 500 37 .115 4/0 19 x .1055 8 .045 2.700 536 8,470 15kV - 100% Insulation Level - ES-13141 2 7 .175 6 7 x .0612 8 .045 1.875 164 2,117 1 19 .175 5 7 x .0688 8 .045 1.940 187 2,477 1/0 19 .175 4 7 x .0772 8 .045 2.025 215 2,742 2/0 19 .175 3 7 x .0867 8 .045 2.110 246 3,130 4/0 19 .175 1 19 x .0664 8 .045 2.330 325 4,385 250 37 .175 1/0 19 x .0745 8 .045 2.450 359 5,400 350 37 .175 2/0 19 x .0837 8 .045 2.700 438 6,730 500 37 .175 4/0 19 x .0940 8 .045 3.050 502 8,515 Information based on AIW specs.

28 www.ptsupply.com [email protected] 800-238-7514 Industrial Grade Cable

Type W Portable Power Cable Bare Copper Conductor 90°C, 2kV Separator EPDM Construction Insulation Manufactured with rope-lay stranded, bunched members, annealed copper conductors. Fillers A polyester or paper tape separates the copper conductors from the EP rubber insula- tion. The insulated conductors are assembled round with fillers as needed. The cable Open is covered with a black CPE rubber jacket. The jacket may be applied in two layers. Reinforcement Two-layer jackets are reinforced by a braid of synthetic material. The reinforcing is CPE between the layers. Jacket

Specifications • Conductors are manufactured in accordance with ASTM B-33 and B-172 • Made in accordance with ICEA S-75-381 - Portable and Power Feeder Cables for Use in Mines and Similar Locations • MSHA accepted, P-7K-123049 LR27151 • UL Listed as Type RHH-RHW-2 per UL 44 • CSA Approved • Meets FT-5 Flame Test

Applications For use in mining machines, locomotives, power supply leads on A.C. welders, motor leads, entertainment, generator leads and grounding cable at continuous conductor temperature of 90°C. Type W cables also are suitable for continuous immersion in shallow water. Excellent flexibility, resistance to oils, solvents, ozone, aging, and abrasion.

No. of Size (AWG Cond. Nom. Insulation Nominal Current Approx. Net Conductors or kcmils) Strand Thick. (in) O.D. (in) Amps Weight (lbs/M-ft) 1 8 133 .060 .485 74 160 1 6 259 .060 .565 99 220 1 4 259 .060 .605 130 290 1 2 259 .080 .680 174 395 1 1 259 .080 .765 202 490 1 1/0 259 .080 .810 234 575 1 2/0 259 .080 .885 271 700 1 3/0 259 .080 .930 313 820 1 4/0 259 .080 .980 361 1,000 1 250 627 .095 1.045 402 1,170 1 350 855 .095 1.145 495 1,520 1 500 1,235 .095 1.310 613 2,090 Also available in 2, 3, 4, 5 conductor. Call for specifications. Information based on Southwire specs.

See referenced pages in the Hardware & Supplies section: Suggested Prep Tools • MK01A Jacket Stripper - I-11 • MK04 Jacket Stripper - I-11

www.ptsupply.com 29 [email protected] 800-238-7514 Airport Lighting Cable

FAA L-824 Type C Stranded Bare Copper 5kV Opaque Separator (or Conductor Shield Construction for ) Shielded or unshielded, single conductor cable with stranded, bare copper XLP Insulation conductor, XLP insulation and PVC jacket on shielded cable. Semi-conducting Insulation Shield* Specifications Bare Copper Meets ICEA S-96-659 for unshielded and ICEA S-93-639 for shielded. Tape Shield*

Applications For installation in ducts, conduit or direct burial for use in airport lighting PVC Jacket* and control circuits. *Shielded cable only.

Conductor Insulation Approx. Approx. Weight AWG Strands Thick. (in) O.D. (in) (lbs/M-ft) Unshielded 8 7 .11 .375 94 6 7 .11 .415 130 4 7 .11 .460 189 Shielded 8 7 .09 .610 175 6 7 .09 .645 240 4 7 .09 .695 305

Information based on AIW specs.

See referenced page in the Hardware & Supplies section: Suggested Prep Tool • WS 49 Airport Lighting Cable End Stripper/Penciller - I-9