PBMR Electrical Systems

Total Page:16

File Type:pdf, Size:1020Kb

PBMR Electrical Systems ElectricalElectrical SystemsSystems Karl Fleming 1 Electric Power Systems The PBMR Electrical System consists of the: ¾ Main Electrical Power System (MEPS) ¾ Auxiliary Electrical Power System (AEPS) February 28 – March 2, 2006 PBMR Safety and Design Familiarization 2 © Copyright 2006 by PBMR (Pty) Ltd. MEPS Functions • Converts the generator output to the network voltage and transmits the power to the network • Accelerates the power turbine generator to synchronous speed during plant starting • Protects the main power generator and the components of the electrical system by disconnecting these components in the event of an electrical fault • Measures the electrical power flowing into and out of the generator and the plant February 28 – March 2, 2006 PBMR Safety and Design Familiarization 3 © Copyright 2006 by PBMR (Pty) Ltd. Normal AC Power Sources • Off-site power is derived from the following sources: ¾ Koeberg 132 kV high-voltage yard ¾ Duyne 132 kV distribution substation • PBMR Generator ¾ When PBMR is not producing power, the AEPS can be supplied with power from the Koeberg 132 kV yard through the Generator transformer and the Module transformer. Alternatively, if this supply is not available, power to the plant’s auxiliaries can be obtained from the Duyne substation. ¾ Power to the auxiliaries can also be supplied from the Duyne substation while the plant is producing power and delivering it to the Koeberg 132 kV substation. February 28 – March 2, 2006 PBMR Safety and Design Familiarization 4 © Copyright 2006 by PBMR (Pty) Ltd. AEPS Functions • Provides and distributes electrical power to plant subsystem electrical loads (house load) • Controls the power to the electrical loads in conjunction with the Control and Instrumentation (C&I) System • Provides back-up power in case of the loss of off-site power • Protects auxiliary electrical and mechanical equipment against damage due to electrical faults, mechanical overload conditions and lightning strikes February 28 – March 2, 2006 PBMR Safety and Design Familiarization 5 © Copyright 2006 by PBMR (Pty) Ltd. Electrical System One-Line Diagram Off-site Off-site 132 kV Network MAIN ELECTRICAL POWER AUXILIARY ELECTRICAL PLANT 11 kV Alternative Supply SYSTEM (MEPS) SYSTEM (AEPS) Electrical Protection, Measurement and Control Generator Transformer Alternative Supply Module Transformer DG DG Main Diesel Main Diesel Generator 1 Generator 2 11 kV Distribution 11 kV Distribution Board 2 Starting transformer Board 1 SFC Auxiliary CBCS Transformers CBCS 400 V Standby Power 400 V Distribution 400 V Standby Power 400 V Distribution Distribution Board 1 Distribution Board 2 EB Board 1 Board 2 DG DG HVAC Starter Board HVAC Starter Board Lighting and Lighting and G Small Power PEM & Recovery Room Small Power PEM & Recovery Room Distribution Board Distribution Board Uninterruptible 690 V Auxiliary Cooling Uninterruptible 690 V Auxiliary Cooling Standby Supplies Distribution Board 1 Standby Supplies Distribution Board 2 GENERATOR SYSTEM (GS) GENERATOR SYSTEM 690 V Cooling Water Pumps 690 V Cooling Water Pumps Distribution Board 1 Distribution Board 2 Train 1 Train 2 Static excitation Electrical Protection and Control Electrical Protection and Control February 28 – March 2, 2006 PBMR Safety and Design Familiarization 6 © Copyright 2006 by PBMR (Pty) Ltd. Earthing AEPS Design Features Characteristic Description House load 7.1 MVA Power quality Normal voltage regulation: ± 5% of nominal voltage Short time voltage regulation: ± 10% of nominal voltage (1 h) Power frequency regulation: ± 2% of 50 Hz Short-time frequency regulation: -5%, +3% of 50 Hz (1 h) Voltage unbalance: negative phase sequence ± 1% of positive phase sequence Motor starting technology Intelligent motor control with communication bus to control system Distribution voltages 11 kV, 690 V, 400 V and 230 V Electromagnetic Compatibility Complies with US Reg. Guide 1.180, EPRI Guideline TR-102323 (EMC) Rev. 2 and relevant sections of IEC 61000 Main Diesel Generators Redundant sets Two local fuel tanks of 3 600 l for 12 h runtime Common fuel tank of 9 600 l Post-Event Monitoring and Redundant sets Recovery Room (PEMRR) Two local fuel tanks of 1 000 l for 24 h runtime diesel generators February 28 – March 2, 2006 PBMR Safety and Design Familiarization 7 © Copyright 2006 by PBMR (Pty) Ltd. Standby Diesel Generators • Two large 11 kV diesel generators are provided, one on each power train. The functions of the standby diesel generators are to provide: ¾ controlled shutdown power; and ¾ power for standby supplies during a loss of power to the station. • Two small 400 V diesel generators are provided to provide back-up power to the PEMRR and the UPS of the Reactor Protection System (RPS) and Post-Event Monitoring System. ¾ These diesel generators and associated switchgear are seismic qualified. February 28 – March 2, 2006 PBMR Safety and Design Familiarization 8 © Copyright 2006 by PBMR (Pty) Ltd. UPS Components UPS Loads 440 V Battery set Electromagnetic Bearing (EMB) supply (1 h) Oil pump motor supply (1 h) Standby lighting supply (1 h) Reactivity Control System (RCS) and Reserve Shutdown System (RSS) (4 h) Reactor Building access control and radiation monitoring (1 h) 220 V Battery set Lubrication oil system 110 V Battery set Electrical protection and control (Circuit-breakers, electrical protection panels, electrical measurement panel, SFC, etc.) 50 V Battery set Tele-control and communication C&I UPS C&I Services Building UPS Access control and radiation monitoring Standby lighting in control room and radiation monitoring area RPS and PEI UPS Reactor protection and post-event monitoring PEMRR UPS Lighting for PEMRR and its diesel generators Cooling Water C&I UPS C&I in the Cooling Water (CW) substation February 28 – March 2, 2006 PBMR Safety and Design Familiarization 9 © Copyright 2006 by PBMR (Pty) Ltd..
Recommended publications
  • Miniature Circuit Breakers, Isolators & Earth Leakage Units: Part 1
    Electrical Miniature circuit breakers, isolators & earth leakage units: Part 1 Heading Here Hi I’m Bra Build• Click it to add text This week Clint is talking about electrical isolators & earth leakage units, explaining the basic applications & mounting options. Remember to use the correct load rated device for your application, ensuring the cable & equipment’s protection at all times. Note ! For the purpose of this presentation, we will be focusing on the miniature circuit breakers (MCBs), isolators & earth leakage units that are more commonly used in the modern day domestic/residential distribution board installations, however these devices are also used in commercial & industrial distribution boards & control panels. Lets Talk device mounting options Lets help you understand how the MCBs, isolators & E/L units are secured in an electrical DB or panel. Commonly used mounting options Electrical distribution board suited for Electrical distribution board suited for DIN mount devices SAMITE/MINI rail mount devices DIN rail SAMITE/MINI rail Important When selecting electrical equipment for a DB or panel installation, you will need to ensure that you select a device that has a mounting base compatible with the mounting rail in the DB or panel where the device is to be installed. Note! Sales staff need to be aware that when supplying a MCB intended to fit into an existing DB installation, although the din MCB may be a cheaper option, a din MCB is not always suitable for use in a mini rail DB & likewise the other way around. It’s always advisable to supply the customer with a MCB that matches the mounting rail currently installed in the customer’s DB.
    [Show full text]
  • Rahi Chu Hydro Electric Project (25 Mw), Sikkim
    RAHI CHU HYDRO ELECTRIC PROJECT (25 MW), SIKKIM EXECUTIVE SUMMARY LOCATION AND ACCESS TO PROJECT SITE Rahi Chu Hydo Electric Project with an installed capacity of 3 x 8.33MW is located in North Sikkim District of Sikkim and is proposed on river Rahi Chu, a tributary of Tolung Chu. The project site is located at about 197 km from Siliguri by road via Singtam & Mangan. Singtam is 100 km from Siliguri (on Siliguri-Gangtok NH-31A) & Singtam to Mangan is about 55 Km. The Diversion site is located at about 42 km from Mangan via Tung Bridge (on River Teesta) & Saffu village. The Diversion site is about 7 km from Saffu village on the Saffu-Sangkalan road presently under construction by BRO. Access road of about 8 Km will be required to be constructed from the Saffu- Sangkalan road to reach the Diversion site. HYDROLOGY The Rahi Chu, is a tributary of Tolung Chu, which in turn is a major tributary of the Teesta. The Rahi The catchment area up to the dam site is about 50 Km2 and lies between Longitude 88o32'25"E to 88o30'55"E and Latitude 27o32'58"N to 27o31'55"N. No site specific G&D data of Rahi Chu is available. Stream flow records (10-daily) of the Tolung Chu at the Sankalang gauge site (Catchment Area = 777 Km2) are available for the period May 1990 – Apr 2004). The flow series for the Panan Hydro-Electric Project was generated by applying a reduction factor of 0.89 on the observed stream flow series at Sankalang (1991-91 to 2003-04) with an annual runoff of 4140 mm, thus arriving at 3684 mm.
    [Show full text]
  • Paralleling Power System Design Considerations and System Level Control Powerhour Webinar Series for Consulting Engineers Experts You Trust
    Paralleling Power System Design Considerations and System Level Control PowerHour webinar series for consulting engineers Experts you trust. Excellence you count on. August 22nd, 2019 11:00 PDT / 13:00 CDT (1PDH issued by Cummins) Welcome! PowerHour is designed to help our engineer partners to… • Keep up to date on products, technology, and codes and standards development • Interact with Cummins experts and gain access to ongoing technical support • Participate at your convenience, live or on-demand • Earn Professional Development Hours (PDH) Technical tips: . Audio is available through teleconference, or your computer (don’t forget to unmute) . You are in “listen only” mode throughout the event . Use the WebEx Q&A Panel to submit questions, comments, and feedback throughout the event. We will provide sufficient Q&A time after presentation . If you lose audio, get disconnected, or experience a poor connection, please disconnect and reconnect . Report technical issues using the WebEx Q&A Panel, or email [email protected] 2 Meet your panelists Cummins presenter: Cummins facilitator: High Resolution Headshot Hassan R Obeid Tom Bakritzes, Global Technical Advisor – Systems and Controls Global Sales Training Manager Cummins Inc. Cummins Inc. Your local Cummins contacts: Western Canada: Ian Lindquist ([email protected]), Western Canada Region South IL, East MO: Jeff Yates ([email protected]), Central Region Eastern Canada: Gianluca Ianiro ([email protected]), Eastern Canada Region TX, OK, AR, LA, MS, AL,
    [Show full text]
  • Smart Solutions for Electrical Distribution in Commercial And
    • MCB Distribution boards • Enclosed motor, heating and enclosures and lighting control • MCCB Panelboards • HRC cartridge fuselinks • Switch and protection devices & fuse units Power distribution components • Industrial switch and fusegear • Power factor correction capacitors Smart solutions for electrical distribution in commercial and industrial applications 2 POWER DISTRIBUTION COMPONENTS PG01414001U – March 2015 Power distribution components Contents 1 Product overview 5 2 Memshield 3 MCB distribution boards and enclosures 31 3 Distribution board switch and protection devices 45 4 Modular control and switching devices 53 5 Memshield 3 MCCB panelboards 65 6 Industrial switch & fusegear 93 7 HRC cartridge fuselinks & fuse units 105 8 Enclosed motor, heating and lighting control 115 9 Power factor correction capacitors 121 10 Technical data 125 Indices 185 POWER DISTRIBUTION COMPONENTS PG01414001U – March 2015 3 4 POWER DISTRIBUTION COMPONENTS PG01414001U – March 2015 Product overview 1 Eaton’s comprehensive range of power distribution solutions have been developed to meet today’s challenging electrical sub-distribution applications in commercial and industrial buildings. Through a proven competency in electrical distribution, Eaton delivers an innovative approach to aid compliance with the wider regulatory requirements associated with modern buildings. 1.1 TYPE A, SPN 125A DISTRIBUTION BOARDS AND PAN ASSEMBLIES ................................................................................... 6 1.2 TYPE B, TPN 125A/250A DISTRIBUTION
    [Show full text]
  • 8196606* 06/2017
    Service, Parts Manual for 6, 3-Row Models, Fan-Cooled and Natural Convection UHC-HD Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. Price: $6.00 24-Hour Service Hotline 1-800-551-8633 819-6606 *8196606* 06/2017 NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS FRYMASTER EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER. THE CABINET IS NOT SUITABLE FOR OUTDOOR USE. WHEN OPERATING THIS UNIT, IT MUST BE PLACED ON A HORIZONTAL SURFACE. THE CABINET IS NOT SUITABLE FOR INSTALLATION IN AN AREA WHERE A WATER JET CAN BE USED. THIS APPLIANCE MUST NOT BE CLEANED WITH A WATER JET. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. DO NOT OPERATE OR SERVICE THE CABINET WITHOUT FIRST READING THIS MANUAL. DO NOT OPERATE THE CABINET UNLESS IT HAS BEEN PROPERLY INSTALLED AND CHECKED. DO NOT OPERATE THE CABINET UNLESS ALL SERVICE AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED. DO NOT ATTEMPT TO REPAIR OR REPLACE ANY COMPONENT OF THE CABINET UNLESS ALL POWER TO THE UNIT HAS BEEN DISCONNECTED.
    [Show full text]
  • Guide To: 17Th Edition Consumer Units Introduction
    Guide to: 17th Edition Consumer Units Introduction For well over one hundred years the Wiring Regulations have provided the rules which must be followed to make sure that electrical installations are safe. The introduction of the 17th Edition of the Wiring Regulations and subsequent amendments have had major implications for all Electrical Contractors, Designers and Consultants. Several regulations have an impact upon circuit design, consumer unit layout and even the construction of the consumer unit itself. This guide will help you understand the new Wiring Regulations and current Building Regulations, providing the necessary facts to construct compliant installations including Consumer Units. If after reading this guide you would like to find out further information regarding the new regulations Hager offer tailored training courses. If you are interested in registering interest in attending one of these courses please visit www.hager.co.uk 2 Guide to | 17th Edition Consumer Units Contents Building Regulations Page 5 Requirements of the 17th Edition Wiring Regulations Page 6 Socket Outlets Page 9 Cables Buried in the Wall Page 10 Special locations Page 12 Other Considerations Page 14 Fire Detection and Alarm Systems for Buildings Page 16 Consumer Unit Arangements Page 18 Conclusions and Training Courses Page 24 Residual Current Devices Used in Consumer Units Page 25 While the author believes that the information and guidance given in this document is correct, all parties must rely upon their own skill and judgement when making use of it. The author does not assume any liability to anyone for loss or damage caused by any error or omission in the work, whether such error or omission is the result of negligence or any other cause.
    [Show full text]
  • 7 CONTROL and PROTECTION of HYDRO ELECTRIC STATION 7.1 Introduction 7.1.1 Control System the Main Control And
    CHAPTER –7 CONTROL AND PROTECTION OF HYDRO ELECTRIC STATION 7.1 Introduction 7.1.1 Control System The main control and automation system in a hydroelectric power plant are associated with start and stop sequence for the unit and optimum running control of power (real and reactive), voltage and frequency. Data acquisition and retrieval is used to cover such operations as relaying plant operating status, instantaneous system efficiency, or monthly plant factor, to the operators and managers. Type of control equipment and levels of control to be applied to a hydro plant are affected by such factors as number, size and type of turbine and generator. The control equipment for a hydro power plant include control circuits/logic, control devices, indication, instrumentation, protection and annunciation at the main control board and at the unit control board for generation, conversion and transmission operation including grid interconnected operation of hydro stations including small hydro stations. These features are necessary to provide operators with the facilities required for the control and supervision of the station’s major and auxiliary equipment. In the design of these features consideration must be given to the size and importance of the station with respect to other stations in the power system, location of the main control room with respect to the equipments to be controlled and all other station features which influence the control system. The control system of a power station plays an important role in the station’s rendering reliable service; this function should be kept in mind in the design of all control features.
    [Show full text]
  • Distribution Board
    Released By: The Development Commissioner (SSI), Ministry of SSI, New Delhi Distribution Board PRODUCT CODE (ASICC) 77308 QUALITY AND STANDARDS IS 8623:1977 IS 2675:1983 PRODUCTION CAPACITY Qty.: 600 Nos. (per annum) Value Rs. 75,00,000 YEAR OF PREPARATION 2002- 2003 PREPARED BY Small Industries Service Institute Vikas Sadan College Square Cuttack - 753003 and Office of the Development Commissioner Small Scale Industries Electrical and Electronics Division 7th Floor, Nirman Bhavan, New Delhi - 110 011. Introduction The Distribution Board, refers to an equipment which consists of bus bars, and possible switches, fuse links and Automatic protective equipment, bypass equipment, for connecting, controlling and protecting a number of branch circuits fed from one main circuit of a wiring installation in a building or premises for easy and safe handling of incoming power supply. These are, also used to protect the electrical distribution system in turn, connected electrical equipment from being damaged due to various faults like short circuit, over load, earth leakage, etc. The Conductor system by means of which electrical energy is conveyed from bulk power source or sources to the consumers is known as distribution system, which may be divided into two systems known as high voltage (primary) distribution and low voltage (secondary distribution). From generating stations the Electrical Power is usually transmitted to various Sub- stations, through extra high tension transmission lines at voltages from 33 to 220 kV and at these Sub-stations this voltage is stepped down to 11 or 6.6 or 3.3 kV and power at this voltage is conveyed to different sub-stations for distribution and to the bulk supply consumer.
    [Show full text]
  • Guideline and Manual for Hydropower Development Vol. 2 Small Scale Hydropower
    Guideline and Manual for Hydropower Development Vol. 2 Small Scale Hydropower March 2011 Japan International Cooperation Agency Electric Power Development Co., Ltd. JP Design Co., Ltd. IDD JR 11-020 TABLE OF CONTENTS Part 1 Introduction on Small Scale Hydropower for Rural Electrification Chapter 1 Significance of Small Scale Hydropower Development ..................................... 1-1 Chapter 2 Objectives and Scope of Manual ......................................................................... 2-1 Chapter 3 Outline of Hydropower Generation ..................................................................... 3-1 Chapter 4 Rural Electrification Project by Small-Scale Hydropower ................................. 4-1 Part 2 Designation of the Area of Electrification Chapter 5 Selection of the Area of Electrification and Finding of the Site .......................... 5-1 Part 3 Investigation, Planning, Designing and Construction Chapter 6 Social Economic Research .................................................................................. 6-1 Chapter 7 Technical Survey ................................................................................................. 7-1 Chapter 8 Generation Plan ................................................................................................... 8-1 Chapter 9 Design of Civil Structures ................................................................................... 9-1 Chapter 10 Design of Electro-Mechanical Equipment .........................................................
    [Show full text]
  • Switching Operator's Manual Distribution Switching
    Switching Operator’s Manual Distribution Switching Document Number: 5011675 SECTION ONE Introduction: Distribution Switching Table of Contents 1. Introduction: Distribution Switching ...................................................... 1-1 1.1 Purpose .............................................................................................. 1-1 1.2 Content .............................................................................................. 1-1 1.2.1 Manual One .................................................................................... 1-1 1.2.2 Manual Two .................................................................................... 1-3 1.3 Switching Operator Authorisation Levels ............................................ 1-3 i Switching Operator's Manual One List of Figures No table of figures entries found. List of Tables No table of figures entries found. ii 1. Introduction: Distribution Switching 1.1 Purpose Manual One provides the switching operator with information on the distribution network configuration, apparatus and switching operations. The manual covers the Horizon Power distribution networks associated with the microgrid and Pilbara Grid systems. Manual Two provides the switching operator with information on the transmission network configuration, apparatus and switching operations. This manual covers the transmission network associated with the Pilbara Grid. Both manuals are intended to be used as a resource for all switching operators and also a major resource for the training modules in
    [Show full text]
  • Microgeneration Installation Standard: MIS 3003
    Microgeneration Installation Standard: MIS 3003 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF MICRO AND SMALL WIND TURBINE SYSTEMS Issue 1.6 This Microgeneration Installation Standard is the property of Department of Energy and Climate Change (DECC), 3 Whitehall Place, London,SW1A 2HH. © DECC 2008 This standard has been approved by the Steering Group of the MCS. This standard was prepared by the MCS Working Group 3 ‘Micro and Small Wind Turbine Systems’. REVISION OF MICROGENERATION INSTALLATION STANDARDS Microgeneration Installation Standards will be revised by issue of revised editions or amendments. Details will be posted on the website at www.microgenerationcertification.org Technical or other changes which affect the requirements for the approval or certification of the product or service will result in a new issue. Minor or administrative changes (e.g. corrections of spelling and typographical errors, changes to address and copyright details, the addition of notes for clarification etc.) may be made as amendments. The issue number will be given in decimal format with the integer part giving the issue number and the fractional part giving the number of amendments (e.g. Issue 3.2 indicates that the document is at Issue 3 with 2 amendments). Users of this Standard should ensure that they possess the latest issue and all amendments. Issue: 1.6 MICROGENERATION INSTALLATION MIS 3003 STANDARD Date: 28/01/2010 Page 2 of 18 TABLE OF CONTENTS 1. SCOPE ............................................................................................................................
    [Show full text]
  • Distribution Systems and Protection Against Indirect Contact and Earth Fault 1SDC007102G0201
    3 Technical Application Papers May 2006 Distribution systems and protection against indirect contact and earth fault 1SDC007102G0201 007_QTvol3GB_COP.indd7_QTvol3GB_COP.indd 3 227-05-20067-05-2006 99:13:52:13:52 Technical Application Papers Distribution systems and protection against indirect contact and earth fault Index 6.2.1 Miniature circuit-breakers System pro M and System pro M compact with 1 Introduction ........................................2 residual current protection ....................23 6.2.2 Residual current releases for Tmax 2 Main defi nitions ..............................3 moulded-case circuit-breakers ..............28 6.2.3 Electronic releases PR… ranges for 3 Protection against earth molded-case and air circuit-breakers with fault integrated residual current protection ....29 6.2.4 Residual current relay with external transformer ...........................................30 3.1 General aspects ......................................5 6.3 The solution with function G ..................31 4 Classifi cation of electrical 6.4 Protection function G or residual current distribution systems protection? ...........................................33 6.4.1 Typical applications of residual current circuit-breakers .....................................33 4.1 TT system ...............................................6 .4.2 Typical applications of moulded-case 4.2 TN system ...............................................6 6 and air circuit-breakers equipped with 4.3 IT system ................................................7 function
    [Show full text]