The Xbpm Project at Max Iv Frontends, Overview and First Results A

Total Page:16

File Type:pdf, Size:1020Kb

The Xbpm Project at Max Iv Frontends, Overview and First Results A Mechanical Eng. Design of Synchrotron Radiation Equipment and Instrumentation MEDSI2018, Paris, France JACoW Publishing ISBN: 978-3-95450-207-3 doi:10.18429/JACoW-MEDSI2018-THPH03 THE XBPM PROJECT AT MAX IV FRONTENDS, OVERVIEW AND FIRST RESULTS A. Bartalesi†, MAX IV Laboratory, Lund, Sweden Abstract trometer, so that when photons hit the blades and elec- All the frontends installed on the 3GeV storage ring at trons are emitted, the electric current flowing out of the MAX IV are equipped with two X-Ray Beam Position blades can be precisely measured. Knowing the photon Monitors. Having recently finished the installation of the cross-section of interaction of Tungsten, the energy and acquisition system, it was possible to record and analyse flux of the white beam and all the involved geometries, it data. This presentation describes the setup and shows the is possible to calculate the theoretical current flowing out first results. of each blade. But most importantly, if the symmetry is not broken anywhere else, imbalances between different INTRODUCTION blade currents are a direct sign of a difference between Since the writing of the technical specifications for the positions of white beam center and XBPM center. MAX IV frontends [1], it was foreseen to include X-ray This particular characteristic of being sensitive to relat- Beam Position Monitors in the design. Being the first real ive signal differences makes these devices quite robust diagnostic tool for the photon beam, and being upstream again other sources of error or uncertainties. For this of all the beamline optics, these devices are capable to de- reason, the XBPM are mounted on top of movable stages, couple beam instabilities and fluctuations originated in and can be moved until the imbalances between different the storage ring from the ones originated the beamlines. blade signals are zeroed. This placement is then fixed and This makes them an important device when trying to pin- maintained for long periods, so that short and long term point the source of a specific disturb. Additionally, they beam movements can be both quantified. can be used to cross check the readouts of the ring BPMs, Finally, there is one important complication: since the and possibly be included in closed loop orbit correction as blades are usually close to each other, the electrons feedback. Finally, being sensitive to energy and flux, and emittted from one blade can end up in another blade, and being the closest diagnostic tool to the synchrotron therefore alter the measurement. This is usually referred sources, they are interesting as a verification of the inser- to as cross talk, but this issue can be avoided completely tion device output. by applying a negative bias voltage to the blade them- selves. The resulting electric field will then prevent emit- WORKING PRINCIPLE ted electrons from ending up in neighbouring blades, and each blade will show a reading that is closed to the theor- The XBPM working principle is based on the photo- etical one. Some XBPM designs take one step further in 2018). Anyelectric distribution of this work must maintain attribution to the author(s), title of the work, publisher,effect: and DOI. the emission of electrons from a material this direction and include an additional positive electrode © when light shine on it. Each XBPM is equipped with in proximity of the blades, that distorts the electric field 4 tungsten blade that are placed in the outer region of the even more favourably. white beam, usually spaced in a way to have symmetries along X and Y in the beam cross section, as shown in Fig- Electric Measurement ure 1. The addition of a negative high voltage bias makes electric measurements slightly more complicated. Consid- ering that we are interested in having really high accuracy, since we are interested in a differential measurement between similar blades, and also considering the small ab- solute value of the currents involved, it is important that all the current produced at a blade is transported to a high accuracy electrometer. The presence of the high voltage bias, however, can lead to very small, but problematic current leakages through the cable insulation. To avoid this problem, triaxial cables are adopted: they consist in a core at the bias voltage carrying the current from blade to electrometer, a first coaxial “shielding” named guard, that carries no signal but is elevated to bias voltage, and a third, proper shielding connected to ground. In this way, having the voltage difference between signal and guard Figure 1: XBPM schematics. equal to zero, we can guarantee no current leakages These blades are then electrically connected to an elec- through the cable insulation. There will be leakages from ______________________________________________ guard to shield, but that has no effect on the measurement. † [email protected] Content fromTHPH03 this work may be used under the terms of the CC BY 3.0 licence ( Beamlines 340 Front Ends Mechanical Eng. Design of Synchrotron Radiation Equipment and Instrumentation MEDSI2018, Paris, France JACoW Publishing ISBN: 978-3-95450-207-3 doi:10.18429/JACoW-MEDSI2018-THPH03 THE ELECTROMETER The quantities X and Y represents movement of the electric signals center, Q is an indication of either a phys- To measure the current of each blade, we adopted the ical tilt, dipole light presence or other asymmetries, and S high voltage EM# electrometer, fruit of a collaboration is mostly related to flux, and therefore stored current and between ALBA synchrotron and MAX IV [2]. This device insertion device gap. Two calibration coefficients K , K is fully capable of the resolution necessary for the XBPM x y are then required to convert X and Y into physical dis- electric measurements, it has four channel and the possib- placements in μm. ilty to add a bias voltage, and finally, its acquisition fre- quency can go as high as 3.2 kHz. These units come with Archiving Strategy an ethernet connection and host a webserver with basic The four values X, Y, Q and S are the ones to be stored, functionalities that help make the setup and first measure- and in particular we are planning to use the newly coming ments extremely quick. A picture of the device is shown MAX IV FA archive, based on the Diamond light source in Fig. 2, while Fig. 3 shows the web interface, with the FA archive [3]; to store a rolling buffer of approximately four channel readings in different colors. two weeks of high frequency data. A slower, periodical beam position archiving will take the data from the fast archive, apply the calibration coeffi- cient, and store the beam position permanently. Finally, at regular intervals, a Fast Fourier Transforma- tion will generate a snapshot of the beam position in the frequency domain, and these snapshots will also be stored permanently. This will allow us to have, at the same time, extremely detailed data to investigate exceptional events, and also long term storage to observe slow phenomena, all without consuming unreasonable amounts of storage space. Figure 2: the EM# electrometer. THE MAX IV SETUP As mentioned above, we will have two XBPMs per frontend on all the 3GeV ring beamlines. Having current- ly eight frontends installed, we are operating sixteen EM# electrometers. Due to the use of short triaxial cables, we installed the electrometers in the storage ring tunnel, with a 50 mm thick lead shielding. At the present time, we re- ceived all electrometers and all cables, we installed some 2018). Any distribution of this work must maintain attribution to the author(s), title of the work, publisher, and DOI. of them with a temporary set up, and we have plans to fin- © ish the permanent installation during the forthcom-ing MAX IV summer shutdown 2018. Fi Figure 3: EM# electrometer web interface. RESULTS DATA HANDLING We currently have most of the XBPM functionalities on three beamlines: NanoMAX, BioMAX and HIPPIE. The The XBPMs acquisition can output the current reading control group installed the first tango devices for the elec- of each blade with a rate of up to 3.2kHz. But more inter- trometers in BioMAX and we were able to perform esting than the raw data, are four derived quantities: X XBPM scans in this beamline: the motors controlling the position, Y position, Q factor, and the sum S. Naming A, X, Y stages of the XBPMs are moved, and the four sig- B, C, D the current readouts of the respective blades ac- nals are recorded together with the axis position. The very cording to Fig. 1; these quantities are defined as follows: first plot obtained with this technique on BioMAX beam- S=A+B+C +D line, XBPM 01, is shown in Figure 4. A+B−C − D This scan allowed us to extract the calibration coeffi- X= cients Kx and Ky, which for these devices are in the order S of 1mm for Kx and 0.5 mm for Ky (ring current 200 mA, A −B −C+D insertion device gap 5mm). This first difference tell us Y = that the device is about twice as sensitive in the X direc- S tion with respect to Y, and this can be traced back to the A −B+C − D white beam cross section. Q= S Beamlines THPH03 Content from this work may be used under the terms of the CC BY 3.0 licence ( Front Ends 341 Mechanical Eng. Design of Synchrotron Radiation Equipment and Instrumentation MEDSI2018, Paris, France JACoW Publishing ISBN: 978-3-95450-207-3 doi:10.18429/JACoW-MEDSI2018-THPH03 CONCLUSIONS The XBPM project at MAX IV is starting to deliver results, as an important diagnostic tool that is showing new, unprecedented information about the 3 GeV storage ring, its alignment, its stability and its insertion devices.
Recommended publications
  • MAX IV Stability Task Force TW
    MAX IV Stability Task Force Update Topical Workshop on Diagnostics for Ultra-Low Emittance Rings (TW-DULER) Brian Norsk Jensen DLS UK, 20th of April 2018 Outline ● Why work on stability? ● The Stability Philosophy at MAX IV ● Tolerances and Goals ● Examples from Construction work for MAX IV ● What has been done inside the Lab? ● Some Ongoing Stuff ● Some things I think we should do Brian Norsk Jensen, MAX IV Laboratory TW-DULER, Diamond Light Source UK, 20/4 2018 Mission: Stable Beams Brian Norsk Jensen, MAX IV Laboratory TW-DULER, Diamond Light Source UK, 20/4 2018 Why Work on Stability? ● Our users need Stable Measurements – Flux – Pointing Stability – Quality of Light (polarization, coherence, free of frequency content,…) – Availability ● The MAX IV Stability Task Force Is Responsible for All Stability! – Accelerators and Beamlines – Procurement Participation – Vibrations – Mechanical – Thermal – Logging – Collecting Input – Problem Solving – Characterization: Seismometers, Accelerometers, Vibrometer, Shaker, … ● Only One Person Specifically Allocated to this Work – I Get and Need Help from Many Colleagues • Mechanical, Accelerator Physicists, IT, Control Room and Beamline Staff, … – I have Great Help from People at the LTH, Dept. of Construction Sciences!!! Brian Norsk Jensen, MAX IV Laboratory TW-DULER, Diamond Light Source UK, 20/4 2018 Strategy and Approach ● Challenges are not always overcome by Fancy or Traditional Solutions ● ZOOM Out! ● Cross Disciplines, Interconnectedness of Things! – Mechanical and Thermal Stability, Magnetic
    [Show full text]
  • The MAX IV Laboratory MAX IV
    Reference network for the new facility at MAX IV Laboratory Pawel Garsztka, MAX IV Laboratory, Lund, SWEDEN Bengt Sommarin, MAX IV Laboratory, Lund, SWEDEN MAX IV The new facility at MAX IV Laboratory consists of the following parts: • 250 meter long LINAC with the maximum 3.4 GeV energy • two storage rings: the smaller ring will have electron energy of 1.5 GeV and a circumference of 96 meters. The bigger ring will have electron energy of 3GeV and a circumference of 528 meters. • SPF (Short-Pulse Facility) In the first phase 7 beamlines will be build. In total 30 beamlines at the two rings will be possible. In addition the MAX IV design also includes an option for the FEL (Free Electron Laser) as a second development stage of the facility. The alignment group is a part of the stability group at MAX IV Laboratory and consisting of two people. Our general task for the near future is to establish the reference network which will be AT 401 in the mock up used for the alignment of all accelerator and beamilne components for the new facility. NETWORK All observations (in three dimensions) will be carried out with only The reference network will be divided in 4 groups joined with one instrument: Leica AT401 laser tracker. The raw data will be each other: pre-analyzed in the Spatial Analyzer software. The final solution, • network 1 - in the ca 300m long LINAC tunnel with transfer based on the least square adjustment will be processed in the lines and SPF (short-pulse facility), PANDA software package.
    [Show full text]
  • Probing a Battery Electrolyte Drop with Ambient Pressure Photoelectron Spectroscopy
    ARTICLE https://doi.org/10.1038/s41467-019-10803-y OPEN Probing a battery electrolyte drop with ambient pressure photoelectron spectroscopy Julia Maibach 1,2, Ida Källquist 3, Margit Andersson4, Samuli Urpelainen 4, Kristina Edström1, Håkan Rensmo3, Hans Siegbahn3 & Maria Hahlin 3 Operando ambient pressure photoelectron spectroscopy in realistic battery environments is a key development towards probing the functionality of the electrode/electrolyte interface in 1234567890():,; lithium-ion batteries that is not possible with conventional photoelectron spectroscopy. Here, we present the ambient pressure photoelectron spectroscopy characterization of a model electrolyte based on 1M bis(trifluoromethane)sulfonimide lithium salt in propylene carbonate. For the first time, we show ambient pressure photoelectron spectroscopy data of propylene carbonate in the liquid phase by using solvent vapor as the stabilizing environment. This enables us to separate effects from salt and solvent, and to characterize changes in elec- trolyte composition as a function of probing depth. While the bulk electrolyte meets the expected composition, clear accumulation of ionic species is found at the electrolyte surface. Our results show that it is possible to measure directly complex liquids such as battery electrolytes, which is an important accomplishment towards true operando studies. 1 Department of Chemistry – Ångström Laboratory, Uppsala University, Box 538, 751 21 Uppsala, Sweden. 2 Institute for Applied Materials (IAM), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. 3 Department of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala, Sweden. 4 MAX IV laboratory, Box 118, 221 00 Lund, Sweden. Correspondence and requests for materials should be addressed to J.M.
    [Show full text]
  • Accelerator and Detector Research and Development Program 2011 Principal Investigators' Meeting Program and Abstracts
    Accelerator and Detector Research and Development Program 2011 Principal Investigators’ Meeting Program and Abstracts The Westin, Annapolis, MD, August 22-23, 2011 Office of Basic Energy Sciences Scientific User Facilities Division NOTE: The printed version of this abstract book is provided in black-and-white; the accompanying CD contains full color versions of all the abstracts. This document was produced under contract number DE-AC05-06OR23100 between the U.S. Department of Energy and Oak Ridge Associated Universities. ABOUT THE COVER Upper left is a 1497 MHz superconducting The initial demonstration of the Echo Enhanced Harmonic cavity which has been optimized for high Generation (EEHG) seeding technique was made with a average current light sources by providing large energy chirp on the beam to shift the EEHG signals high acceleration gradients, large apertures, relative to the High Gain Harmonic Generation (HGHG) low losses, and substantial higher order signals: PRL, 105: 114801 (2010). The top plot shows the mode (HOM) damping. The damping is measured radiation spectrum with just the laser at 1590-nm provided through three HOM waveguides on modulating the beam while the middle plot shows the each end of the cavity with an axial rotation spectrum with the 790-nm laser modulating the beam. The to provide coupling to all bunching measured in both these cases is due to the HGHG modes. Fundamental power can be fed to process. The bottom plot shows the result with both lasers the cavity through one or more of the same modulating the beam. The additional EEHG signals can be waveguides. seen (E1, E2, and E3).
    [Show full text]
  • Vacuum Systems and Resources at MAX IV Laboratory
    MAX IV R&D Accelerator division seminars Vacuum systems and resources at MAX IV laboratory 18th September 2018, MAX IV, Lund Vacuum systems and resources at MAX IV laboratory, 18th September 2018 1 Marek Grabski Contents • What is vacuum - why do we need it in particle accelerators? • Basics of vacuum technology, • Gas sources, • Pumping technology, • Outlook of MAX IV storage ring vacuum systems, • Introduce vacuum team and services. Vacuum systems and resources at MAX IV laboratory, 18th September 2018 2 Marek Grabski What is vacuum? Vacuum is a space with no matter inside – practically not possible to achieve. Vacuum in engineering and physics is a space in which the pressure is lower than atmospheric pressure and is measured by its absolute pressure. Low pressure High pressure (high vacuum) (low vacuum) Force [N] 2 Pressure is Area [m2] measured in Pascals, 1 [Pa] = 1 N/m Vacuum systems and resources at MAX IV laboratory, 18th September 2018 3 Marek Grabski What is vacuum? The force exerted on the walls of an evacuated vessel surrounded by atmospheric pressure is: 1 kg/cm2 Atmospheric pressure Vacuum Vacuum systems and resources at MAX IV laboratory, 18th September 2018 4 Marek Grabski Pressure units Conversion table: units of pressure In vacuum technology: mbar or Pa Vacuum systems and resources at MAX IV laboratory, 18th September 2018 5 Marek Grabski Vacuum ranges 1 Atm. = 1013 mbar =~ 1 bar Pressure range [mbar] Low Vacuum 103 - 1 Medium Vacuum 1 - 10-3 High Vacuum (HV) 10-3 - 10-9 Ultra High Vacuum (UHV) 10-9 - 10-12 Extreme
    [Show full text]
  • Annual Report of MAX IV Laboratory to the Swedish Research Council
    Dnr: STYR 2017/384 Annual Report of MAX IV Laboratory to the Swedish Research Council 2016 Contents 1 Introduction ................................................................................................................ 3 2 Organisational matters ............................................................................................... 3 3 User operation ............................................................................................................ 4 3.1 Scientific Output ................................................................................................. 5 4 Accelerators at MAX IV Laboratory ............................................................................ 5 5 Communication and Outreach .................................................................................... 7 6 Engagement with Industry .......................................................................................... 8 7 Financial report with comments ................................................................................. 9 8 International and national collaborations ................................................................ 10 Appendix International agreements and collaborations entered 2016 ........................... 11 Annual Report of MAX IV Laboratory to the Swedish Research Council 2 1 Introduction 2016 has for MAX IV Laboratory been a year out of the ordinary in the sense that we have not had regular user operation. Since MAX-lab at Ole Römers väg was closed down 13 December 2015, focus has
    [Show full text]
  • Arxiv:2006.02821V1 [Physics.Acc-Ph] 4 Jun 2020
    Proceedings of the 2017 CERN–Accelerator–School course on Vacuum for Particle Accelerators, Glumslöv, (Sweden) Brief Introduction to Particle Accelerators P. F. Tavares MAX IV Laboratory, Lund, Sweden Abstract This lecture is a brief introduction to charged particle accelerators. The aim is to provide the reader with basic concepts and tools needed to describe the motion of charged particles under the action of guiding and focussing fields, with an emphasis on those aspects that are relevant to understanding and quan- tifying how accelerator vacuum systems affect accelerator performance. Even though the focus is on electron accelerators and, in particular, electron storage rings used as synchrotron light sources, most of the concepts described are of general application to a wider class of particle accelerators. Keywords Particle accelerators; electron beam optics; Twiss parameters. 1 Assumptions and Goals In writing these notes, I have assumed that the reader is familiar with relativistic mechanics and elec- tromagnetic theory at the advanced undergraduate or beginning graduate level. I have not assumed any previous knowledge of accelerators or charged particle beam dynamics. The aims of this lecture are: 1. to provide motivations for developing and building particle accelerators; 2. to describe the basic building blocks of a typical particle accelerator; 3. to describe the basic concepts and tools needed to understand how the vacuum system affects accelerator performance. Caveat: I will focus the discussion/examples mostly concerning one type of accelerator, namely electron storage rings optimized as sources of synchrotron radiation, although most of the discussion can be translated into other accelerator models. The interested reader can find all of the material presented here discussed at length in a number of by now classical references.
    [Show full text]
  • SOLARIS Synchrotron
    SOLARIS synchrotron What is a synchrotron? A synchrotron is a cyclic accelerator, i.e. a de- laps in one second! In order for the electrons to vice in which particles are accelerated and travel rush around on a closed-loop path, their movement around a fixed closed-loop path (in contrast to line- path is curved by twelve blocks of electromagnets. ar accelerators in which accelerated particles move Electromagnetic radiation called synchrotron light in a straight line). is generated in the places where the path of the In the SOLARIS synchrotron, electrons circulate. electrons is curved. They are produced in an electron gun and trans- The synchrotron light is taken out of the synchro- ferred to a linear accelerator, where they are ac- tron: first it goes to the so-called beamlines and celerated to a speed close to the speed of light in then to end stations, where it is used for scientific a vacuum. Then these electrons are injected to the research. synchrotron, where they perform over three million A synchrotron Synchrotron light is is a device unique. Its extraordinary that produces properties include its enor- synchrotron light mous intensity; it is millions used for scientific of times brighter than the research. Beamline light that comes to the Earth from the Sun. In addition, syn- chrotron radiation contains elec- tromagnetic waves all the way from the Synchrotron infrared spectrum, through visible and ultraviolet light Circular motion of electrons light, and up to X-rays. Thanks to this, scientists can study various materials in many ways, both Creation externally and internally.
    [Show full text]
  • Beamline Status MAX IV September 2020
    DNR: STYR 2020/725-3 Status of beamlines at MAX IV September 2020 Status of MAX IV MAX IV accelerators are performing well, and all three deliver X-ray light to beamlines. Fourteen beamlines are currently taking light, four of which are in commissioning and ten in general user operation. The Covid-19 pandemic has had a dramatic impact on research activities globally. Despite this challenging environment, MAX IV accelerators and beamlines continue to operate according to schedule. The principal impact of the pandemic on research at MAX IV is that most users have not been able to come to MAX IV for their scheduled beamtime. MAX IV users have cancelled about 30 user projects since the last report.1 Nevertheless, all beamlines are working together with their users to find solutions to serve them under these unprecedented circumstances. Several beamlines, e.g. BioMAX, Balder, MAXPEEM, and NanoMAX, are serving users remotely with mail-in samples. In order to support science towards understanding the SARS-CoV-2 virus-related disease, and to bring us closer to an effective vaccine, diagnostics or treatment, MAX IV offers its instrumentation and beamtime through a rapid access mode to facilitate these efforts. Two user groups have utilised rapid access mode so far. The first results have been analysed and are about to be submitted for publication. MAX IV will reschedule users who could not use beamtime scheduled during the spring 2020 cycle due to the pandemic for beamtime in the upcoming autumn 2020 cycle. In addition, MAX IV will extend this cycle to allocate beamtime to highly ranked proposals in the spring call.
    [Show full text]
  • Approach of Serial Crystallography II
    crystals Editorial Approach of Serial Crystallography II Ki-Hyun Nam Department of Life Science, Pohang University of Science and Technology, Pohang 37673, Gyeongbuk, Korea; [email protected] Abstract: Serial crystallography (SX) is an emerging X-ray crystallographic method for determining macromolecule structures. It can address concerns regarding the limitations of data collected by conventional crystallography techniques, which require cryogenic-temperature environments and allow crystals to accumulate radiation damage. Time-resolved SX studies using the pump-probe methodology provide useful information for understanding macromolecular mechanisms and struc- ture fluctuation dynamics. This Special Issue deals with the serial crystallography approach using an X-ray free electron laser (XFEL) and synchrotron X-ray source, and reviews recent SX research involving synchrotron use. These reports provide insights into future serial crystallography research trends and approaches. Serial crystallography (SX) experiments using an X-ray free electron laser (XFEL) with a short pulse width, or short time X-ray (<100 ms) exposure in a synchrotron, minimize ra- diation damage to crystals compared with traditional X-ray crystallographic methods [1,2]. Moreover, SX data collection at room temperature provides more biologically reliable data on structural dynamics in macromolecules compared to cryo-crystallographic tech- niques [3–5]. In addition, in SX data collection, if a crystal sample is stimulated with a pump, such as an optical laser or a ligand/inhibitor solution, and then diffraction data are collected by exposure to X-rays after a selected time delay. This can time-resolve molecu- lar mechanisms of macromolecules [6,7]. Thus, SX techniques provide more biologically Citation: Nam, K.-H.
    [Show full text]
  • Evaluation of the Modified Max Iv Proposal 2009
    Synchrotron radiation is today a versatile and widespread scientific tool. The MAX-laboratory in Lund has proposed a new synchrotron radiation facility, named MAX IV, intended to deliver spontaneous as well as coherent radiation of very high quality over a broad spectral range. The technical design and scientific case of the proposal were evaluated in 2005 and 2006 and indicated that the proposed MAX IV facility would offer a world leading and unique light source of importance to competitive science in a wide range of scientific disciplines. Since then, preparations have been made for the construction of the MAX IV facility, including drafting of a modified technical design of the facility in order to better meet upcoming user needs. A panel of international experts has scrutinized the new technical design of MAX IV and their conclusions and recommendations are presented in this report. EVALUATION OF THE MODIFIED MAX IV PROPOSAL 2009 Klarabergsviadukten 82 | Box 1035 | SE-101 38 Stockholm | SWEDEN | Tel +46-8-546 44 000 | [email protected] | www.vr.se The Swedish Research Council is a government agency that provides funding for basic research of the highest scientific quality in all disciplinary domains. Besides research ISSN 1651-7350 funding, the agency works with strategy, analysis, and research communication. ISBN 978-91-7307-181-9 The objective is for Sweden to be a leading research nation. VETENSKAPSRÅDETS RAPPORTSERIE 12:2010 EVALUATION OF THE MODIFIED MAX IV PROPOSAL 2009 EVALUATION OF THE MODIFIED MAX IV PROPOSAL 2009 This report can be ordered at www.vr.se VETENSKAPSRÅDET Swedish Research Council Box 1035 101 38 Stockholm, SWEDEN © Swedish Research Council ISSN 1651-7350 ISBN 978-91-7307-181-9 Graphic Design: Erik Hagbard Couchér, Swedish Research Council Cover Photo: MAX IV Design proposal Printed by: CM-Gruppen AB, Bromma, Sweden 2010 PREFACE The Council for Research Infrastructure (RFI) at the Swedish Research Council has the overall responsibility to ensure that research infrastructure of the highest quality is expanded and exploited.
    [Show full text]
  • MAX IV STRATEGY 2030 a First Draft to Invite Community Input
    MAX IV STRATEGY 2030 A First Draft to Invite Community Input th 15 March 2021 EXECUTIVE SUMMARY MAX IV Strategy 2021-2030 This is a preliminary version of a science-driven strategy to guide development of MAX IV through 2030. It is not the final strategy document. Community input to and critical review of this strategy process from all MAX IV stakeholders over the coming months is essential to its success. We aim with close participation from stakeholders to complete a full strategy document in autumn 2022. The mission of MAX IV is to provide the research (i) Accelerator science community with world-class tools for synchrotron (ii) Health and Medicine x-rays at the highest level of excellence and societal (iii) Tackling environmental challenges benefit. This mission includes and serves the (iv) Energy storage and technologies academic and industrial communities conducting (v) Quantum and advanced materials (vi) Ultrafast science research in applied as well as fundamental and basic science. These communities span a broad Some classes of techniques are so broad in range of scientific fields from life, chemistry, application or cut through so many other metho- physics, environmental, engineering, and materials dologies they deserve special mention, specifically: sciences to cultural heritage. (a) Imaging, (b) Dynamics, and (c) Data handling MAX IV is committed to supporting and advancing and AI & ML Swedish and international academic and industrial A key outcome of the strategy process will be a research in these areas, especially the ones aiming roadmap to plan new capabilities and instruments to develop a more sustainable future in concert at MAX IV, and upkeep necessary to maintain with the UN global sustainable development goals current capabilities internationally competitive, in (SDGs).
    [Show full text]