CHM 130 - Accuracy and the Measurement of Volume
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Laboratory Glassware N Edition No
Laboratory Glassware n Edition No. 2 n Index Introduction 3 Ground joint glassware 13 Volumetric glassware 53 General laboratory glassware 65 Alphabetical index 76 Índice alfabético 77 Index Reference index 78 [email protected] Scharlau has been in the scientific glassware business for over 15 years Until now Scharlab S.L. had limited its sales to the Spanish market. However, now, coinciding with the inauguration of the new workshop next to our warehouse in Sentmenat, we are ready to export our scientific glassware to other countries. Standard and made to order Products for which there is regular demand are produced in larger Scharlau glassware quantities and then stocked for almost immediate supply. Other products are either manufactured directly from glass tubing or are constructed from a number of semi-finished products. Quality Even today, scientific glassblowing remains a highly skilled hand craft and the quality of glassware depends on the skill of each blower. Careful selection of the raw glass ensures that our final products are free from imperfections such as air lines, scratches and stones. You will be able to judge for yourself the workmanship of our glassware products. Safety All our glassware is annealed and made stress free to avoid breakage. Fax: +34 93 715 67 25 Scharlab The Lab Sourcing Group 3 www.scharlab.com Glassware Scharlau glassware is made from borosilicate glass that meets the specifications of the following standards: BS ISO 3585, DIN 12217 Type 3.3 Borosilicate glass ASTM E-438 Type 1 Class A Borosilicate glass US Pharmacopoeia Type 1 Borosilicate glass European Pharmacopoeia Type 1 Glass The typical chemical composition of our borosilicate glass is as follows: O Si 2 81% B2O3 13% Na2O 4% Al2O3 2% Glass is an inorganic substance that on cooling becomes rigid without crystallising and therefore it has no melting point as such. -
A Simple Spectrophotometric Method for the Determination Of
J Clin Pathol: first published as 10.1136/jcp.14.2.202 on 1 March 1961. Downloaded from 202 Technical methods usual laboratory filters may give falsely increased values.) Of the clear and colourless filtrate 10 ml. is pipetted into A a 25 ml. measuring flask and 10 ml. reagent (3) added. simple spectrophotometric After mixing dilute with distilled water to the mark and method for the determination of renew mixing. After 10 minutes the mixture is ready for reading. The colour is stable, according to Watt and urea in blood and urine Chrisp, for 11 days. READING T. K. WITH, TOVE DREYER PETERSEN, AND BIRGIT PETERSEN From the Central Laboratory, Svend- The reactions are read in a spectrophotometer at 420 nm. borg County Hospital, Denmark with a blank prepared in the same way as the reaction mixture but with 3 ml. of distilled water instead of 3 ml. of blood. The urea standard (reagent 4) is treated in the Several methods for urea in determining blood and urine same way as the blood. Cuvettes of 1 cm. thickness are are in use in clinical laboratories, but none is ideal in suitable. mass routine The analysis. spectrophotometric method If p, s, and b are the extinctions of the the based on a modified Ehrlich sample, reagent proposed by Watt standard, and the blank respectively, the urea concen- and Chrisp (1954) for pure solutions is therefore of tration is interest because it can be modified for use in mass clinical analyses of blood and urine. Brown (1959) has l00(p-b)/(s-b) mg./100 ml. -
Environmental Chemistry Method Methoxyfenozide & Degradates In
Dow AgroSciences LLC Study ID: 110356 Page 12 Method Validation Study for the Detennination of Residues of Methoxyfenozide and its A-ring • Phenol Metabolite and B-ring Mono Acid Metabolite in Surface Water, Ground Water and Drinking Water by Liquid Chromatography with Tandem Mass Spectrometry INTRODUCTION J This method is applicable for the quantitative detennination of residues of methoxyfenozide and its A-ring phenol metabolite and B-ring mono acid metabolite in surface, ground and drinking water. The method was validated over the concentration range of 0.05-1.0 µg/L with a validated limit of quantitation of 0.05 µg/L. Common names, chemical names, and molecular formulas for the analytes are given in Table I. This study was conducted to fulfill data requirements outlined in the EPA Residue Chemistry Test Guidelines, OPPTS 850. 7100 (/). The validation will also comply with the requirements of EU Council Regulation (EC) No. 1107/2009 with particular regard to Section 3 of SANCO/3029/99 rev.4 and Section 3 of SANCO/825/00 rev.8.1 as well as PMRA Regulatory Directive Dir98-02 (2-4). The validation was conducted following Dow AgroSciences SOP ECL-24 with exceptions noted in the protocol or by protocol amendment. Method Principle Residues of methoxyfenozide, its A-ring phenol metabolite and its B-ring mono acid metabolite • are extracted from water samples by taking a l 0.0-mL aliquot and placing in an I I -dram (45-mL) glass vial equipped with a PTFE-lined cap or a 50-mL polypropylene centrifuge tube equipped with a cap. -
Rebecca Has Samples of Different Types of Metal, and She Wants to Find the Density of Each
Rebecca has samples of different types of metal, and she wants to find the density of each. First, she measures the volume of each sample. Now she needs to measure the samples' masses. Which of the following tools should Rebecca use to measure the mass of each sample? A. measuring tape B. calipers C. graduated cylinder D. balance Question 2 Add Ken needs to measure out 50 mL of water. Which of the following is the best tool for Ken to use? A. balance B. ruler C. spring scale D. graduated cylinder Question 3 Add Emily sees the following tool in her science lab. What is this tool used to measure? A. an object's volume B. an object's density C. an object's mass D. an object's length Question 4 Add Tamora is heating a liquid to find the temperature at which the liquid boils. Which piece of laboratory equipment should Tamora use to measure the temperature of the liquid once the boiling has begun? A. timer B. balance C. microscope D. thermometer Question 5 Add Which of the following laboratory tools would be most appropriate for measuring the approximate volume of a liquid? A. thermometer B. beaker C. balance D. tweezers Question 6 Add Directions: Select the correct answer from each drop-down menu. Mass can be measured using a volume can be measured using a and length can be measured using a Question 7 Add Betty is studying vein patterns in leaves. Which of the following tools could help Betty examine the leaves' veins in greater detail? A. -
Laboratory Equipment Reference Sheet
Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position. -
Laboratory Supplies and Equipment
Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout -
I. Direct Titration of Sulfate, II. High Precision Spectrophotometric Analysis Max Quentin Freeland Iowa State College
Iowa State University Capstones, Theses and Retrospective Theses and Dissertations Dissertations 1955 I. Direct titration of sulfate, II. High precision spectrophotometric analysis Max Quentin Freeland Iowa State College Follow this and additional works at: https://lib.dr.iastate.edu/rtd Part of the Analytical Chemistry Commons Recommended Citation Freeland, Max Quentin, "I. Direct titration of sulfate, II. High precision spectrophotometric analysis" (1955). Retrospective Theses and Dissertations. 14746. https://lib.dr.iastate.edu/rtd/14746 This Dissertation is brought to you for free and open access by the Iowa State University Capstones, Theses and Dissertations at Iowa State University Digital Repository. It has been accepted for inclusion in Retrospective Theses and Dissertations by an authorized administrator of Iowa State University Digital Repository. For more information, please contact [email protected]. INFORMATION TO USERS This manuscript has been reproduced from the microfilm master. UMi films the text directly from the original or copy submitted. Thus, some thesis and dissertation copies are in typewriter face, while others may be from any type of computer printer. The quality of this reproduction is dependent upon the quality of the copy submitted. Broken or indistinct print, colored or poor quality illustrations and photographs, print bleedthrough, substandard margins, and improper alignment can adversely affect reproduction. In the unlikely event that the author did not send UMI a complete manuscript and there are missing pages, these will be noted. Also, if unauthorized copyright material had to be removed, a note will indicate the deletion. Oversize materials (e.g., maps, drawings, charts) are reproduced by sectioning the original, beginning at the upper left-hand comer and continuing from left to right in equal sections with small overlaps. -
Spectrophotometric and Potentiometric Determination of Ph Introduction Determination of Ph Is One of the Most Frequently Perform
Spectrophotometric and Potentiometric Determination of pH Introduction Determination of pH is one of the most frequently performed measurements in chemistry. The potentiometric method with a glass electrode has been widely used for pH measurements but has drawbacks such as the need for a reference electrode, susceptibility to electrical interference, instrument drift, and the need for physical contact with the solution. It is desirable to have alternative methods for pH determination. One such method is spectrophotometric measurement with the use of a suitable pH indicator. In the spectrophotometric method used here, the pH of an unknown solution is determined by addition of a small amount of a pH indicator and determination of the extent of dissociation of the indicator (a weak acid). Because overlap exists between the spectra for the acid form (generically represented as Hln) and base form (In-) of the indicator, it is necessary to determine individual molar absorptivities for each form at two wavelengths (λ1 and λ2). Usually these are the wavelength peaks (absorption maxima) of HIn and In-. Assuming that the absorbances of the two forms are additive (independent of one another), we obtain two simultaneous linear equations for the absorption at the two wavelengths measured: HIn In- - A1 = ε1 b [HIn] + ε1 b [In ] (1a) HIn In- - A2 = ε2 b [Hin] + ε2 b [In ] (1b) where b is the pathlength (usually 1 cm), A1 and A2 are the absorbances at λ1 and λ2, HIn HIn ε1 and ε2 are the molar absorptivities of Hln at λ1 and λ2, and In- In- - ε1 and ε2 are the molar absorptivities of ln at λ1 and λ2 . -
32-9-2.5.2 Stop TB Global Drug Facility Diagnostics Catalog [.Pdf]
OCTOBER 2019 DIAGNOSTICS CATALOG GLOBAL DRUG FACILITY (GDF) PHOTO: MAKA AKHALAIA PHOTO: Ensuring an uninterrupted supply of quality-assured, affordable tuberculosis (TB) medicines and diagnostics to the world. stoptb.org/gdf Stop TB Partnership | Global Drug Facility Global Health Campus – Chemin du Pommier 40 1218 Le Grand-Saconnex | Geneva, Switzerland Email: [email protected] Last verion's date: 08 October 2019. Stop TB Partnership/Global Drug Facility licensed this product under an Attribution-NonCommercial-NoDerivatives 4.0 International License. (CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode GLOBAL DRUG FACILITY DIAGNOSTICS CATALOG OCTOBER 2019 GDF is the largest global provider of quality-assured tuberculosis (TB) medicines, diagnostics, and laboratory supplies to the public sector. Since 2001, GDF has facilitated access to high-quality TB care in over 130 countries, providing treatments to over 30 million people with TB and procuring and delivering more than $200 million worth of diagnostic equipment. As a unit of the Stop TB Partnership, GDF provides a full range of quality-assured products to meet the needs of any TB laboratory globally. GDF provides more than 500 diagnostics products, including the latest WHO-approved TB diagnostic devices and reagents, together with the consumables and ancillary devices required to ensure a safe working environment. These products cater to all levels of laboratories, ranging from peripheral health centers to centralized reference laboratories, and provide countries with the latest WHO-recommended technologies for detecting TB and drug resistance. To place an order for any diagnostics product, please follow the step-by-step guide available on the GDF website. -
SPECIAL SCIENTIFIC REPORT-FISHERIES Na 349
349 CHEMICAL ANALYSES OF MARINE AND ESTUARINE WATERS USED BY THE GALVESTON BIOLOGICAL LABORATORY SPECIAL SCIENTIFIC REPORT-FISHERIES Na 349 UNITED STATES DEPARTMENT OF THE INTERIOR FISH AND WILDLIFE SERVICE United States Department of the Interior, Fred A. Seaton, Secretary Fish and Wildlife Service, Arnie J. Suomela, Commissioner Bureau of Commercial Fisheries, Donald L, McKernan, Director CHEMICAL ANALYSES OF MARINE AND ESTUARINE WATERS USED BY THE GALVESTON BIOLOGICAL LABORATORY by Kenneth T. Marvin, Zoula P. Zein-Eldin, Billie Z. May and Larence M. Lansford Chemists Galveston, Texas United States Fish and Wildlife Service Special Scientific Report— Fisheries No. 349 Washington, D. C. June 1960 CONTENTS Introduction 1 Sample treatment prior to analysis 1 Sample storage containers 2 Analytical methods 2 Standard samples 2 Phosphate 3 Inorganic only 3 Total and inorganic 3 Total only 4 Nitrate-nitrite 5 Nitrite 5 Salinity 6 Copper 6 Sulfide 7 Oxygen 7 Total carbon dioxide 8 Ammonia 10 Chlorophyll 10 "Carbohydrates" 11 "Protein" (tyrosine equivalent) 12 Washing procedure for all analytical glassware 12 Literature cited 13 111 CHEMICAL AMLYSES OF MAP.INE AND ESTOARIKE mTERS USED BY TBE GALVESTON BIOLOGICAL lABORATORY by Kenneth T. Marvin, Zoula P. Zein-Eldin, Billie Z. May and Larence M. Lansford ABSTRACT This paper describes the chemical techniques and procedures used hy the Biological lahoratory of the U. S. Bureau of Commercial Jlsherles, Galveston^ Texas, for analyzing samples Involved In the chemical and hlo- logical survey of the marine and estuarlne waters of the Gulf of Mexico and also In the many laboratory and field studies and experiments that have heen made pertaining to the red tide investigation. -
Laboratory Equipment Used in Filtration
KNOW YOUR LAB EQUIPMENTS Test tube A test tube, also known as a sample tube, is a common piece of laboratory glassware consisting of a finger-like length of glass or clear plastic tubing, open at the top and closed at the bottom. Beakers Beakers are used as containers. They are available in a variety of sizes. Although they often possess volume markings, these are only rough estimates of the liquid volume. The markings are not necessarily accurate. Erlenmeyer flask Erlenmeyer flasks are often used as reaction vessels, particularly in titrations. As with beakers, the volume markings should not be considered accurate. Volumetric flask Volumetric flasks are used to measure and store solutions with a high degree of accuracy. These flasks generally possess a marking near the top that indicates the level at which the volume of the liquid is equal to the volume written on the outside of the flask. These devices are often used when solutions containing dissolved solids of known concentration are needed. Graduated cylinder Graduated cylinders are used to transfer liquids with a moderate degree of accuracy. Pipette Pipettes are used for transferring liquids with a fixed volume and quantity of liquid must be known to a high degree of accuracy. Graduated pipette These Pipettes are calibrated in the factory to release the desired quantity of liquid. Disposable pipette Disposable transfer. These Pipettes are made of plastic and are useful for transferring liquids dropwise. Burette Burettes are devices used typically in analytical, quantitative chemistry applications for measuring liquid solution. Differing from a pipette since the sample quantity delivered is changeable, graduated Burettes are used heavily in titration experiments. -
Art of the Pipet Advanced Site Search by Jay A
Magazine: Feature 1 Research Journal News & Books & Science Web Reviews Tools Collection Comment Labware Jobs Links Latest Today's Magazine Conference Journal Special My E-mail Site news.bmn.com Commentary Updates News HMS Beagle Reporter Scan Report Alerts Search My BMN Exit Feedback Help Magazine HMS Beagle Current Issue Table of Contents What's New Search Email Alerts Back Issues Read Letters HMS Beagle Staff FEATURE 1 Contributors Call for Contributions Call for Illustrations How to Cite Us Quick Site Search The Art of the Pipet Advanced site search by Jay A. Martin Posted April 13, 2001 · Issue 100 Abstract In the last quarter century, the adjustable mechanical pipet has become an ergonomically correct and precise tool for researchers. A combination of artistry and innovation inspired its evolution. People who spend most of their adult lives at the bench gain a lifelong friend - the adjustable mechanical pipet. Like the bricklayers and masons who built a great city with the "stones of Venice," we can admire the scientists and engineers who built better lab tools for us. "It is less the actual loveliness of the thing produced," says Ruskin, "than the choice and invention concerned in the production, which are to delight us." Because of its advanced design, today's air-displacement pipet dispenses liquids with high accuracy. (In an air-displacement pipet, an air pocket always lies between the liquid and a piston. In positive-displacement pipets, a piston makes direct contact with the drawn liquid.) Rainin's L-2 Pipet-Lite, for instance, can pick up 1.0 µL of liquid with 3 percent accuracy.