Precision Optics for Precision Shooting

Total Page:16

File Type:pdf, Size:1020Kb

Precision Optics for Precision Shooting PRECISION OPTICS FOR PRECISION SHOOTING Glass-etched illuminated reticles are standard with every Sand, dust, mud, heat and cold are a few of the environmental Nightforce scope. challenges every Nightforce scope faces in its development. Every aspect is thoroughly tested, proven, and tested again before we build a fi nal You cannot buy a higher quality rifl escope. product. Anything you can infl ict upon a scope, you can be certain we’ve already done it fi rst. That’s a strong claim, without a doubt. But, it’s a claim we can prove. And our customers do prove it…every The terms “rugged” and day, under some of the harshest, most unforgiving conditions on earth. “precision optics” are usually not compatible. Any optical We didn’t start building scopes and expect people to fi nd uses for instrument built to highly them. Instead, we looked at real-world needs. Needs that were not The spring that maintains exacting tolerances and absolute being met by other optics. And created, from the ground up, the pressure on our elevation and alignment is by its very nature a ultimate precision instrument for the intended application. windage adjustments spends delicate device. You can tell the difference the moment you pick one up. And if you two weeks in a polishing Not so with Nightforce. could look inside a Nightforce scope, the differences would be even tumbler before going into a The design of our scopes is Turret adjustments are made more obvious. Nightforce scope, to assure unique within the industry, with specially treated hardened Fortunately, just looking through one will tell you just about there are no rough spots or allowing us to combine optics metals, and advanced dry everything you need to know. burrs to interfere with perfectly of extraordinary precision with fi lm lubricants and surface- smooth operation. It is made of construction that will withstand hardened brass silicone bronze pure titanium, the only known repeated recoil from the largest are used to ensure a lifetime metal in the world that can be calibers, extreme shock and of wear resistance and reliable repeatedly compressed and severe temperature changes. performance. This combination All air-to-glass surfaces Every lens in a Nightforce scope held in place, even for years, is not the easiest way to build receive our proprietary is matched and aligned by hand without developing fatigue or a scope. It is, however, the best broadband multi-coating; perfectly to its partners. This “memory.” This guarantees zero way to build a scope…providing a applied to tolerances of 1/4 technique, called optical indexing, loss of integrity, zero loss of lifetime of repeatable accuracy. wave deposition or .000005 yields the highest possible optical repeatability. It is many times inches, exceeding the toughest performance. Because it takes time more expensive than comparable Lenses are painstakingly bedded Mil-Spec abrasion test. You will and considerable expertise, many springs found in most scopes. We machine the screw that with our own proprietary Mil-Spec see the difference in low- manufacturers don't bother. We've But, we are not concerned with controls elevation adjustments formulation. Unlike methods light situations. done it this way since the beginning. a few dollars. We are concerned to an unbelievable 110 threads with building the best rifl escope. used by most other scope per inch. It is so precise that it manufacturers, with our bedding must be mated to its receiver by process there is no glass-to- hand. Why go to so much trouble? metal contact that can result in Because we consider backlash breakage, stress or misalignment clearance of more than 1/30 over time. Our process is 100% the thickness of a human hair permanent, guaranteeing perfect unacceptable. optical alignment for as long as you own your Nightforce scope. A scope’s objective lens Nightforce tubes are machined determines resolution, light from solid bar stock 6061-T6 transmission and exit pupil size. To aircraft-grade aluminum alloy, The optical elements within an maximize these attributes, every not extruded or formed like those NXS scope are hand-bedded with Nightforce objective lens assembly found on lesser scopes. They our own proprietary Mil-Spec the optical elements in any utilizes a multi-element design like are two to three times thicker than bonding agent, then cured at 160o direction, under any circumstance. those found in the highest quality other rifl escopes. This means less F for 24 hours. Lenses are further This permanent bonding assures telescopes. Our lens system overall stress, greater thermal secured with O-rings and machined a lifetime of uncompromising focuses light rays more precisely stability, a consistent zero and a metal lock rings, both fore and aft. performance and reliability, for exceptional image clarity and virtually impervious shield for the This zero-tolerance lens securing confi rmed with front and side impact color accuracy. precision optics within. method prevents any movement of testing on every scope we build. WHAT SOME COMPANIES CALL CLOSE TOLERANCES WE CALL INTOLERABLE. 2 3 NFUSA_Cat_BdyNov08.indd 2-3 12/16/08 11:36:16 AM Mil-Radian target turrets are an option on Nightforce 3.5-15 NXS scopes. These provide precise Mil-Radian angular units of measure for 3.5-15 x 50 NXS both windage and elevation, an ideal interface Military & law enforcement Originally developed for use on military small arms, the with our Mil-Dot or MLR reticles. Adjustments are Long-range hunting 3.5-15x50 NXS allows a lower mounting profi le. calibrated in 0.1 mil. click values and 5.0 mil. per A practical magnifi cation range and large fi eld of view revolution, allowing an easy return to zero. make it an invaluable scope for professionals and serious hunters as well. A full 110 MOA of internal adjustment make both 3.5-15 models extremely versatile in the fi eld and applicable to a wide range of applications. CREATED FOR PEOPLE WHOSE LIVES DEPEND ON THEIR SCOPE. The hole you see in the well-used Nightforce 3.5-15x50 NXS scope at right was made by an enemy 7.62x39 round fi red at a U.S. soldier. The bullet completely penetrated the erector tube—the heart of the scope's optical system. We’re happy to report that the Our scopes are subjected soldier was not injured, and the only to abuse during product casualty is the scope's magnifi cation development that would quickly ring, frozen on 15x. Its focus, tracking, destroy lesser optics. Pre- and all other functions work just fi ne. It production scopes are tested in a holds point of aim like new. pressure tank simulating 100 feet of water for 24 hours, ensuring The soldier wrapped the scope in duct absolute waterproof integrity. We tape to keep out sand and dirt, and test thermal stability by freezing used it without a problem for the next them to -80o F, then heating them three days, completing his mission. to 200o F within a one-hour period. We receive many stories like this. Function is checked at both Because Nightforce rifl escopes are temperature extremes. Recoil and used in active theatres by most of the 3.5-15 x 56 NXS impact are tested at 1,250 Gs for elite special forces worldwide, they are both positive and negative forces. subjected to—and survive—the most The top choice for law enforcement snipers. A large brutal conditions imaginable. objective lens increases resolution and exit pupil size for Before it is shipped to a customer, quicker target acquisition and optimal light performance in every scope is completely We won't say they're bulletproof. twilight conditions…an especially useful confi guration for inspected and checked at over There is at least one soldier, however, tactical teams that may not have a dedicated night vision 70 different points. A battery of who would argue otherwise. scope. This superior optical design also benefi ts hunters tests, including forward impact, and sport shooters who want a scope to perform in the side impact, tracking accuracy shadows. It offers a full 110 MOA of adjustment and a practical and resolution integrity. These are magnifi cation range. A large fi eld of view allows the shooter to Military & law enforcement but a few of the steps we take to recover quickly from recoil for a second shot. Long-range hunting insure absolute quality before any scope leaves our facility. Whatever you think you might do to your scope, chances are we’ve already done it. 4 5 NFUSA_Cat_BdyNov08.indd 4-5 12/16/08 11:36:22 AM 5.5-22 x 50 NXS Military & law enforcement Originally developed for the U.S. military’s extreme long Long-range hunting range shooting and hard target interdiction, both 5.5-22 Nightforce models provide a broad magnifi cation range, four inches of eye relief and 100 MOA of elevation travel. These characteristics have proven highly appropriate for the .50 Once again, using Nightforce scopes, the USAMU BMG, allowing shooters to accurately reach to 2000 yards Service Rifl e Team cleaned house at the 2008 and beyond. It retains a slim profi le and is easily adaptable Interservice Highpower Championships and 2008 NRA to a wide range of mounting systems. The superb resolution Long Range Championships: at high magnifi cation also opens an entirely new world of • First, second and third place/600 yard Division B Mil-Radian target turrets are an option on extended range for the accomplished marksman. (any rifl e, any sight), including a new match record Nightforce 5.5-22 NXS scopes.
Recommended publications
  • Breaking Down the “Cosine Fourth Power Law”
    Breaking Down The “Cosine Fourth Power Law” By Ronian Siew, inopticalsolutions.com Why are the corners of the field of view in the image captured by a camera lens usually darker than the center? For one thing, camera lenses by design often introduce “vignetting” into the image, which is the deliberate clipping of rays at the corners of the field of view in order to cut away excessive lens aberrations. But, it is also known that corner areas in an image can get dark even without vignetting, due in part to the so-called “cosine fourth power law.” 1 According to this “law,” when a lens projects the image of a uniform source onto a screen, in the absence of vignetting, the illumination flux density (i.e., the optical power per unit area) across the screen from the center to the edge varies according to the fourth power of the cosine of the angle between the optic axis and the oblique ray striking the screen. Actually, optical designers know this “law” does not apply generally to all lens conditions.2 – 10 Fundamental principles of optical radiative flux transfer in lens systems allow one to tune the illumination distribution across the image by varying lens design characteristics. In this article, we take a tour into the fascinating physics governing the illumination of images in lens systems. Relative Illumination In Lens Systems In lens design, one characterizes the illumination distribution across the screen where the image resides in terms of a quantity known as the lens’ relative illumination — the ratio of the irradiance (i.e., the power per unit area) at any off-axis position of the image to the irradiance at the center of the image.
    [Show full text]
  • Geometrical Irradiance Changes in a Symmetric Optical System
    Geometrical irradiance changes in a symmetric optical system Dmitry Reshidko Jose Sasian Dmitry Reshidko, Jose Sasian, “Geometrical irradiance changes in a symmetric optical system,” Opt. Eng. 56(1), 015104 (2017), doi: 10.1117/1.OE.56.1.015104. Downloaded From: https://www.spiedigitallibrary.org/journals/Optical-Engineering on 11/28/2017 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use Optical Engineering 56(1), 015104 (January 2017) Geometrical irradiance changes in a symmetric optical system Dmitry Reshidko* and Jose Sasian University of Arizona, College of Optical Sciences, 1630 East University Boulevard, Tucson 85721, United States Abstract. The concept of the aberration function is extended to define two functions that describe the light irra- diance distribution at the exit pupil plane and at the image plane of an axially symmetric optical system. Similar to the wavefront aberration function, the irradiance function is expanded as a polynomial, where individual terms represent basic irradiance distribution patterns. Conservation of flux in optical imaging systems is used to derive the specific relation between the irradiance coefficients and wavefront aberration coefficients. It is shown that the coefficients of the irradiance functions can be expressed in terms of wavefront aberration coefficients and first- order system quantities. The theoretical results—these are irradiance coefficient formulas—are in agreement with real ray tracing. © 2017 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.OE.56.1.015104] Keywords: aberration theory; wavefront aberrations; irradiance. Paper 161674 received Oct. 26, 2016; accepted for publication Dec. 20, 2016; published online Jan. 23, 2017. 1 Introduction the normalized field H~ and aperture ρ~ vectors.
    [Show full text]
  • Nikon Binocular Handbook
    THE COMPLETE BINOCULAR HANDBOOK While Nikon engineers of semiconductor-manufactur- FINDING THE ing equipment employ our optics to create the world’s CONTENTS PERFECT BINOCULAR most precise instrumentation. For Nikon, delivering a peerless vision is second nature, strengthened over 4 BINOCULAR OPTICS 101 ZOOM BINOCULARS the decades through constant application. At Nikon WHAT “WATERPROOF” REALLY MEANS FOR YOUR NEEDS 5 THE RELATIONSHIP BETWEEN POWER, Sport Optics, our mission is not just to meet your THE DESIGN EYE RELIEF, AND FIELD OF VIEW The old adage “the better you understand some- PORRO PRISM BINOCULARS demands, but to exceed your expectations. ROOF PRISM BINOCULARS thing—the more you’ll appreciate it” is especially true 12-14 WHERE QUALITY AND with optics. Nikon’s goal in producing this guide is to 6-11 THE NUMBERS COUNT QUANTITY COUNT not only help you understand optics, but also the EYE RELIEF/EYECUP USAGE LENS COATINGS EXIT PUPIL ABERRATIONS difference a quality optic can make in your appre- REAL FIELD OF VIEW ED GLASS AND SECONDARY SPECTRUMS ciation and intensity of every rare, special and daily APPARENT FIELD OF VIEW viewing experience. FIELD OF VIEW AT 1000 METERS 15-17 HOW TO CHOOSE FIELD FLATTENING (SUPER-WIDE) SELECTING A BINOCULAR BASED Nikon’s WX BINOCULAR UPON INTENDED APPLICATION LIGHT DELIVERY RESOLUTION 18-19 BINOCULAR OPTICS INTERPUPILLARY DISTANCE GLOSSARY DIOPTER ADJUSTMENT FOCUSING MECHANISMS INTERNAL ANTIREFLECTION OPTICS FIRST The guiding principle behind every Nikon since 1917 product has always been to engineer it from the inside out. By creating an optical system specific to the function of each product, Nikon can better match the product attri- butes specifically to the needs of the user.
    [Show full text]
  • Technical Aspects and Clinical Usage of Keplerian and Galilean Binocular Surgical Loupe Telescopes Used in Dentistry Or Medicine
    Surgical and Dental Ergonomic Loupes Magnification and Microscope Design Principles Technical Aspects and Clinical Usage of Keplerian and Galilean Binocular Surgical Loupe Telescopes used in Dentistry or Medicine John Mamoun, DMD1, Mark E. Wilkinson, OD2 , Richard Feinbloom3 1Private Practice, Manalapan, NJ, USA 2Clinical Professor of Opthalmology at the University of Iowa Carver College of Medicine, Department of Ophthalmology and Visual Sciences, Iowa City, IA, USA, and the director, Vision Rehabilitation Service, University of Iowa Carver Family Center for Macular Degeneration 3President, Designs for Vision, Inc., Ronkonkoma, NY Open Access Dental Lecture No.2: This Article is Public Domain. Published online, December 2013 Abstract Dentists often use unaided vision, or low-power telescopic loupes of 2.5-3.0x magnification, when performing dental procedures. However, some clinically relevant microscopic intra-oral details may not be visible with low magnification. About 1% of dentists use a surgical operating microscope that provides 5-20x magnification and co-axial illumination. However, a surgical operating microscope is not as portable as a surgical telescope, which are available in magnifications of 6-8x. This article reviews the technical aspects of the design of Galilean and Keplerian telescopic binocular loupes, also called telemicroscopes, and explains how these technical aspects affect the clinical performance of the loupes when performing dental tasks. Topics include: telescope lens systems, linear magnification, the exit pupil, the depth of field, the field of view, the image inverting Schmidt-Pechan prism that is used in the Keplerian telescope, determining the magnification power of lens systems, and the technical problems with designing Galilean and Keplerian loupes of extremely high magnification, beyond 8.0x.
    [Show full text]
  • TELESCOPE to EYE ADAPTION for MAXIMUM VISION at DIFFERENT AGES. the Physiological Change of the Human Eye with Age Is Surely
    TELESCOPE TO EYE ADAPTION FOR MAXIMUM VISION AT DIFFERENT AGES. The physiological change of the human eye with age is surely contributing to the poorer shooting performance of older shooters. This is regardless of the fact that the refractive deviation of the eyes is generally faithfully corrected with lenses or surgery (laser procedures) and hopefully optometrically restored again to 6/6 effectiveness. Also, blurred eye lenses (cataracts) get replaced in the over sixty group. So, what then is the reason for seeing “poorer” through the telescope after the above? The table below speaks volumes about this. The iris opening (pupil size) of the eye determines the amount of light (the eye pupil in mm diameter) that enters the eye under specific light conditions. This amount of light, actually photons in the sight spectrum that contains the energy to activate the retina photoreceptors, again determines the clarity of the information / image interpreted by the brain via the retina's interaction. As we grow older, less light is entering the eye because the iris dilator muscle adaptability weakens as well as slows down. Average eye pupil diameter change versus age Day iris Night iris Age in years opening in opening in mm mm 20 4.7 8 30 4.3 7 40 3.9 6 50 3.5 5 60 3.1 4.1 70 2.7 3.2 80 2.3 2.5 The following calculations, based on the values in the table above, show how drastic these eye pupil changes are on our sight due to the less light that enters the eye.
    [Show full text]
  • Part 4: Filed and Aperture, Stop, Pupil, Vignetting Herbert Gross
    Optical Engineering Part 4: Filed and aperture, stop, pupil, vignetting Herbert Gross Summer term 2020 www.iap.uni-jena.de 2 Contents . Definition of field and aperture . Numerical aperture and F-number . Stop and pupil . Vignetting Optical system stop . Pupil stop defines: 1. chief ray angle w 2. aperture cone angle u . The chief ray gives the center line of the oblique ray cone of an off-axis object point . The coma rays limit the off-axis ray cone . The marginal rays limit the axial ray cone stop pupil coma ray marginal ray y field angle image w u object aperture angle y' chief ray 4 Definition of Aperture and Field . Imaging on axis: circular / rotational symmetry Only spherical aberration and chromatical aberrations . Finite field size, object point off-axis: - chief ray as reference - skew ray bundels: y y' coma and distortion y p y'p - Vignetting, cone of ray bundle not circular O' field of marginal/rim symmetric view ray RAP' chief ray - to distinguish: u w' u' w tangential and sagittal chief ray plane O entrance object exit image pupil plane pupil plane 5 Numerical Aperture and F-number image . Classical measure for the opening: plane numerical aperture (half cone angle) object in infinity NA' nsinu' DEnP/2 u' . In particular for camera lenses with object at infinity: F-number f f F# DEnP . Numerical aperture and F-number are to system properties, they are related to a conjugate object/image location 1 . Paraxial relation F # 2n'tanu' . Special case for small angles or sine-condition corrected systems 1 F # 2NA' 6 Generalized F-Number .
    [Show full text]
  • The F-Word in Optics
    The F-word in Optics F-number, was first found for fixing photographic exposure. But F/number is a far more flexible phenomenon for finding facts about optics. Douglas Goodman finds fertile field for fixes for frequent confusion for F/#. The F-word of optics is the F-number,* also known as F/number, F/#, etc. The F- number is not a natural physical quantity, it is not defined and used consistently, and it is often used in ways that are both wrong and confusing. Moreover, there is no need to use the F-number, since what it purports to describe can be specified rigorously and unambiguously with direction cosines. The F-number is usually defined as follows: focal length F-number= [1] entrance pupil diameter A further identification is usually made with ray angle. Referring to Figure 1, a ray from an object at infinity that is parallel to the axis in object space intersects the front principal plane at height Y and presumably leaves the rear principal plane at the same height. If f is the rear focal length, then the angle of the ray in image space θ′' is given by y tan θ'= [2] f In this equation, as in the others here, a sign convention for angles heights and magnifications is not rigorously enforced. Combining these equations gives: 1 F−= number [3] 2tanθ ' For an object not at infinity, by analogy, the F-number is often taken to be the half of the inverse of the tangent of the marginal ray angle. However, Eq. 2 is wrong.
    [Show full text]
  • 6-1 Optical Instrumentation-Stop and Window.Pdf
    6.6. OpticalOptical instrumentationinstrumentation Last chapter ¾ Chromatic Aberration ¾ Third-order (Seidel) Optical Aberrations Spherical aberrations, Coma, Astigmatism, Curvature of Field, Distortion This chapter ¾ Aperture stop, Entrance pupil, Exit pupil ¾ Field stop, Entrance window, Exit window Aperture effects on image ¾ Depth of field, Depth of focus ¾ prism and dispersion ¾ Camera ¾ Magnifier and eyepiece Optical instruments ¾ Microscope ¾ Telescope StopsStops inin OpticalOptical SystemsSystems Larger lens improves the brightness of the image Image of S Two lenses of the same formed at focal length (f), but the same diameter (D) differs place by both lenses SS’ Bundle of rays from S, imaged at S’ More light collected is larger for from S by larger larger lens lens StopsStops inin OpticalOptical SystemsSystems • Brightness of the image is determined primarily by the size of the bundle of rays collected by the system (from each object point) • Stops can be used to reduce aberrations StopsStops inin OpticalOptical SystemsSystems How much of the object we see is determined by: Field of View Q Q’ (not seen) Rays from Q do not pass through system We can only see object points closer to the axis of the system Thus, the Field of view is limited by the system ApertureAperture StopStop • A stop is an opening (despite its name) in a series of lenses, mirrors, diaphragms, etc. • The stop itself is the boundary of the lens or diaphragm • Aperture stop: that element of the optical system that limits the cone of light from any particular object point on the axis of the system ApertureAperture StopStop (AS)(AS) E O Diaphragm E Assume that the Diaphragm is the AS of the system Entrance Pupil (E P) Entrance Pupil (EnnP) The entrance pupil is defined to be the image of the aperture stop in all the lenses preceding it (i.e.
    [Show full text]
  • Parallax Adjustment for Riflescopes
    Parallax Adjustment For Riflescopes As applied to riflescopes, parallax can be defined as the apparent movement of objects within the field of view in relation to the reticle. Parallax occurs when the “primary image” of the object is formed either in front of, or behind the reticle. If the eye is moved from the optical axis of the scope, this also creates parallax. Parallax does not occur if the primary image is formed on the same focal plane as the reticle, or if the eye is positioned in the optical axis of the scope. Riflescopes with high magnification, or scopes for long-range shooting should be equipped with a parallax adjustment because even slight sighting errors can seriously affect sighting accuracy. By adjusting the objective part of the optical system the target can be brought in the exact focal plane of the reticle at any distance. Tactical style riflescopes do not usually have parallax adjustment because the exact range of the target can never be anticipated. Lower magnification scopes do not usually have parallax adjustment either since at lower powers the amount of parallax is very small and has little importance for practical, fast target sighting accuracy. Factors That Affect the Amount of Parallax in a Riflescope Two main factors that cause and affect the amount of parallax in a riflescope. First is the distance of the target to the objective lens of the riflescope. Since the reticle is in a fixed position within the riflescope housing, the image of the target doesn’t always appear positioned in the same plane as the reticle.
    [Show full text]
  • Affect of Eye Pupil on Binocular Aperture by Ed Zarenski August 2004
    Copyright (c) 2004 Cloudy Nights Telescope Reviews Affect of Eye Pupil on Binocular Aperture by Ed Zarenski August 2004 This information has been discussed before, elsewhere in other forums and also here in the CN binocular forum. However, the question keeps coming up and it is certainly worthwhile to document all of this in one complete discussion. In a telescope, you can vary the exit pupil by changing the eyepiece. In a fixed power binocular the exit pupil you purchase is the exit pupil you live with. The question answered here is this: What happens when your eye pupil is smaller than the binocular exit pupil? The implications are not at all intuitive, and certainly without explanation may not be clearly understood. There has been much prior debate over this issue, some of which I have participated in. Research, as always, provides some answers. Hopefully, this article will answer the question for you. Clear skies, and if not, Cloudy Nights Edz Aug. 2004 The author practices astronomy from his home in Cumberland, R. I. How big are your eye pupils? An important aspect to consider when choosing any binocular is the maximum dilation of your own eye pupils. Your own eyes may have a significant impact on the effective performance of a binocular. Depending on your desired use, failing to take maximum dilated eye pupil into consideration before you make your purchase may lead to an inappropriate choice. Exit pupil larger than eye pupil results in not realizing the maximum potential of the binocular. There are several simple methods to determine the size of you eye pupils.
    [Show full text]
  • Optics for Birding – the Basics
    Optics for Birding – The Basics A Wisconsin Society for Ornithology Publicity Committee Fact Sheet Christine Reel – WSO Treasurer Arm yourself with a field guide and a binocular and you are ready to go birding. The binocular – a hand-held, double- barreled telescope – uses lenses and roof or porro prisms to magnify images generally between 6 and 12 times. Some birds are too distant for easy viewing with a binocular. At these times, a spotting scope – a single-barrel telescope with a magnification of generally 15 to 60 power using zoom or interchangeable fixed eyepieces – makes all the difference. Remember that a scope is not a substitute for a binocular, because it must be fitted to a tripod or another stabilizing device, and maneuverability and portability are limited. Optics shopping Buying a binocular or scope is a lot like buying a car: do some research, set some minimum standards, and then look at special features and options; also consider a number of choices and compare them. Keep in mind that there is no perfect binocular or scope, only one that is perfect for you. It must fit your hands, your face, your eyes, your size, and the way you bird. 1. Research. Plan to visit a local birding site or club meeting and ask a few birders what binoculars or scopes they prefer and why. Then choose a store or nature center that is geared toward birders and has a large selection of optics. Research the various specifications and what they mean to your birding experience (use this sheet as a starting point).
    [Show full text]
  • Binoculars NAME GROUP
    SIERRA COLLEGE OBSERVATIONAL ASTRONOMY LABORATORY EXERCISE Lab N04: Binoculars NAME GROUP OBJECTIVE: Learn about binocular magnification, aperture, field of view. Calculate resolution, light gathering power, limiting magnitude, and exit pupil. Time permitting, observe some binocular objects. INTRODUCTION: Binoculars are surprisingly sophisticated devices. A pair of binoculars consists of two refracting telescopes, so each telescope can service a separate eye. To work, the two separate telescopes are carefully aligned at the factory. The internal optics of binoculars bounce the light around in complicated, folded paths—this makes binoculars very compact and convenient to use. Binoculars do not have interchangeable eyepieces. Therefore, they only provide one magnification. The magnification and aperture (in mm) of a set of binoculars are always printed on the instrument, as a pair of numbers. Aperture and objective diameter are synonymous. The field of view of binoculars indicates how much of the sky you can see through the binoculars. The field of view is measured in degrees. The fine detail that you can see is referred to as the resolution. The resolution is measured in arcseconds—the smaller the resolution number, the smaller the details that can be seen. The resolution of the human eye is approximately 60 arcseconds. The resolution of an optical system depends upon the diameter of the objective, and can be estimated using Equation 1. Equation 1: Resolution of an objective The large lenses of binoculars also collect more light than the human eye. The light gathering power of a lens is calculated using Equation 2. Equation 2: Light gathering power of two objectives D1 and D2 are the objective diameters being compared.
    [Show full text]