The Barrel DIRC detector of PANDA

C. Schwarza,∗, A. Alia,b, A. Beliasa, R. Dzhygadlo,a, A. Gerhardta, M. Krebsa,b, D. Lehmanna, K. Petersa,b, G. Schepersa, J. Schwieninga, M. Traxlera, L. Schmittc, M. Bohm¨ d, A. Lehmannd, M. Pfaffingerd, F. Uhligd, S. Stelterd, M. Duren¨ e, E. Etzelmuller¨ e, K. Fohl¨ e, A. Hayrapetyane, K. Kreutzfelde, J. Riekee, M. Schmidte, T. Waseme, P. Achenbachf, M. Cardinalif, M. Hoekf, W. Lauthf, S. Schlimmef, C. Sfientif, M. Thielf

aGSI Helmholtzzentrum f¨urSchwerionenforschung GmbH, Darmstadt, Germany bGoethe University, Frankfurt a.M., Germany cFAIR, Facility for Antiproton and Ion Research in Europe, Darmstadt, Germany dFriedrich Alexander-University of Erlangen-Nuremberg, Erlangen, Germany eII. Physikalisches Institut, Justus Liebig-University of Giessen, Giessen, Germany fInstitut f¨urKernphysik, Johannes Gutenberg-University of Mainz, Mainz, Germany

Abstract The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the cou- 32 −2 −1 pling constant αs & 0.3. The luminosity of up to 2 · 10 cm s and the momentum resolution of the antiproton beam down to ∆p/p = 4·10−5 allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between 22◦ and 140◦ and will achieve a pion-kaon separation of 3 standard deviations up to 3.5 GeV/c. Here, results of a test beam are shown for a single radiator bar coupled to a prism with 33◦ opening angle, both made from synthetic fused silica read out with a detector array with 768 pixels. Keywords: Particle identification, Cherenkov detectors, DIRC principle PACS: 29.40.Ka

1. Introduction

The PANDA experiment [1] employs several particle iden- tification (PID) systems for its physics program [2]. Two of them are Cherenkov counters using the DIRC (Detection of In- ternally Reflected Cherenkov light) principle which allow for building compact PID systems. This is accomplished by using the radiators as light guides for the produced Cherenkov pho- tons to a photon detector outside of the active volume. The first of such detectors was built and successfully operated by the BaBar experiment [3, 4]. The Barrel DIRC described here, separates pions from kaons with at least 3 standard deviations (s.d.) up to momenta of 3.5 GeV/c.

2. Design

arXiv:1901.08432v1 [physics.ins-det] 24 Jan 2019 The design of the PANDA Barrel DIRC [5, 6] is based on the design of the BABAR DIRC with several improvements. The radius of the 16-sided polygonal barrel is 476 mm. To elimi- nate photon background from neutrons hitting the large water tank between the radiators and photon detectors observed by BaBar it was replaced by 16 smaller 30 cm-deep prisms made Figure 1: Schematic of the Barrel DIRC baseline design [5].

∗Corresponding author Email address: [email protected] (C. Schwarz)

Preprint submitted to Elsevier January 25, 2019 from synthetic fused silica. Coupled to each prism are three radiator bars and a photon detector array of eleven lifetime- 60 pions

enhanced Microchannel-Plate (MCP) PMTs [7] on the oppo- entries 50 protons site readout side. Each radiator bar has a thickness 17 mm, a width of 53 mm, and a length of 2400 mm. The DIRC detec- 40 tor is partitioned in 16 independent segments with radiators and 30 an expansion volume with the photon detector that can be dis- 20 mounted from the radiators. The separation into smaller ”cam- 10 eras” and the usage of synthetic fused silica was already favored 0 −40 −30 −20 −10 0 10 20 30 40 by the SuperB FDIRC [8] and the Belle II TOP [9]. The reduc- ln L(p) - ln L(π) tion in size and the finite radiator bar size requires focusing the onto the photon detector. Space limitations within the Figure 2: One of the figure of merits for the performance of the Barrel DIRC is the proton-pion log-likelihood difference distributions for proton-tagged (red) magnetic yoke of the target spectrometer solenoid excludes the and pion-tagged (blue) beam events. Here, the result for the focusing with the usage of focusing mirrors. A three-layer spherical compound three-layer spherical lens is shown. lens between radiator bar and expansion prism is used to get a sharp Cherenkov image. The readout electronics is based on the HADES Trigger Readout Board (TRB) [10] and front end References amplification and discriminator cards directly mounted on the [1] PANDA Collaboration, Technical Progress Report, FAIR-ESAC/Pbar, MCP-PMTs[11]. (2005). [2] PANDA Collaboration, Physics Performance Report for PANDA: Studies with Antiprotons, arXiv:0903.3905. 3. Beam tests [3] P. Coyle, The DIRC counter: a new type of particle identification device for B factories, Nucl. Instr. and Meth. Res. Sect. A, 343 (2004) 292. After several test beam campaigns at GSI and CERN in the [4] I. Adam et al., The DIRC particle identification system for the BaBar recent years, the campaign at the CERN PS 2017 served the experiment, Nucl. Instr. and Meth. Res. Sect. A 538 (2005) 281. validation of the baseline design together with slight changes [5] J. Schwiening et al. The PANDA Barrel DIRC, JINST 13 (2018) C03004. [6] PANDA Collaboration, Technical Design Report for the PANDA Barrel of the setup compared to previous beam times. The prototype DIRC Detector, arXiv:1710.00684v1. consisted of the important elements for one bar box: A fused [7] A. Lehmann et al., Recent Developments with Microchannel-Plate PMTs, silica bar (17.1 × 35.9 × 1200.0 mm3) was coupled on one end Nucl. Instr. and Meth. Res. Sect. A, 876 (2017) 42. to a flat mirror, on the opposite end to a focusing lens and the [8] B. Dey et al., Design and performance of the focusing DIRC detector, Nucl. Instr. and Meth. Res. Sect. A, 775 (2015) 112. fused silica prism as optical expansion volume. Latter had an [9] P. Krizan, Particle identification at Belle II, JINST 9 (2014) C07018. opening angle of 33◦ and allowed, different from previous beam [10] C. Ugur et al., A 16 channel high resolution (< 11 ps RMS) Time-to- times [5, 12], for coupling 12 MCP-PMTs with 64 pixels each. Digital Converter in a Field Programmable Gate Array, JINST 7 (2012) C02004. Two focusing lenses, a spherical and a cylindrical one, made [11] M. Cardinali et al., Frontend electronics for high-precision single photo- from LaK33B [13] glass were used for tests. Proton and pion timing using FPGA-TDCs, Nucl. Instr. and Meth. Res. Sect. A beam particles were tagged by a time-of-flight system. The re- 766 (2014) 231. constructed particle type comes from the comparison of the ar- [12] C. Schwarz et al. The PANDA DIRC detectors at FAIR, JINST 12 (2017) C07006. rival time of the photons at each MCP-PMT pixel and the ex- [13] Schott AG, glass catalogue, LaK33B data sheet. pected arrival time from simulation (time-based imaging). The [14] S. Agostinelli, Geant4 A simulation toolkit, Nucl. Instr. and Meth. Res. log-likelihood difference distribution obtained using time-based Sect. A 506 (2003) 250. imaging for a polar angle of 25◦ and a momentum of 7 GeV/c is shown in Fig. 2 together with Gaussian fits. A π/p performance of 4.0 ± 0.1 s.d. is observed. It deteriorates to 3.0 ± 0.1 s.d. when using a three-layer cylindrical lens for focusing. Simula- tion [6, 14] are used to extrapolate the result for the three-layer spherical lens to the expected π/K separation power. With the expected photon detection efficiency and timing precision of the MCP-PMTs in the Barrel DIRC, a π/K separation power of about 6.6 s.d. at 25◦ and 3.5 GeV/c is achieved. This excellent result allows for studying the performance of the setup with a reduced number or photon detectors in coming experiments to achieve a cost optimization.

Acknowledgments This work was supported by HGS-HIRe, HIC for FAIR, BNL eRD14. We thank the GSI and CERN staff for the opportunity to use the beam facilities and for their on-site support. 2