ITU inter-regional seminar

Technical Realisation of Digital TV Systems

Friedrich Rottensteiner Rohde & Schwarz

7TSP ITU inter-regional seminar 1 DVB-T Transmitter system

Technical Realisation of Digital TV Transmitter Systems

- MFN / SFN networks

- Transition from analog to digital

- state of the art transmitter family

- redundancy systems

7TSP ITU inter-regional seminar 2 DVB-T transmitter systems

Network layout

MFN SFN (multi frequency network) (single frequency network)

7TSP ITU inter-regional seminar 3 SFN -network

Advantages of the SFN:

* Frequency efficiency - the DVB-T system use the SFN: one frequency for several programs

(current situation: each program has another frequency ==> MFN: Multi Frequency Network)

- the SFN is with the factor of 3 better than the MFN's

* Power efficiency - lower transmitter power in the SFN is required because

- addition of all signal components from different and reflection at the receiving

- with the lower transmitter output power: lower in neighbor areas

- if gaps exists in the coverage (deep valley, tunnels, etc.): these gaps can be filled

7TSP ITU inter-regional seminar 4 SFN-network

Disadvantages of the SFN:

* the TS is equal at all transmitter sites (no local program can be introduced)

* a transmitter which violates the SFN rules is a jammer in the coverage

* synchronization (time, frequency, information) is necessary

* network monitoring is necessary to control the SFN features

7TSP ITU inter-regional seminar 5 DVB-T transmitter chain SFN

MPEG-2 TS

RX MPEG-2 SYNC DVB-T Network system modulator TS adapter

10 MHz 1 pps TX MPEG-2 SFN Distribution remultiplexer adapter Network GPS* adapter Network

10 MHz 1 pps RX SYNC DVB-T Network GPS* system modulator adapter

MPEG-2 10 MHz 1 pps TS * Could be any common available frequency reference GPS*

7TSP ITU inter-regional seminar 6 DVB-T transmission network (via Satellite)

Transmitter n

Private NNI

TV digital MPEG 2 + DVB-S

Transmitter 1 Private NNI

7TSP ITU inter-regional seminar 7 DVB-T transmission network (via Radio Link/dark fiber)

7TSP ITU inter-regional seminar 8 DVB-T transmission network (via ATM/SDH)

digital Studio 1

MPEG 2

Private UNI GPS Private NNI 1 pps

GPS 1 pps Public UNI Transmitter n NET 1 Private NNI digital Studio 2

MPEG 2 Private UNI B ISDN MIP Network MUX inserter Adapter

Public NNI

Public NNI digital Studio n

MPEG 2

Public UNI Public NNI

NET 2 GPS 1 pps

Transmitter 1

Private NNI

7TSP ITU inter-regional seminar 9 DVB-T network monitoring

7TSP ITU inter-regional seminar 10 DVB-T networks monitoring

program source data rate entire TS program - TS single programs elementary streams protocol- parameters of parameter 1. priority 2. priority 3. priority tables presence repetition rate picture quality DVQL - W DVQL - U TA SA event protocol all unusual events summed up in REPORT

program source repeatable measurement measurement-TS sequences for comparable measurements

MIP insertion monitoring of PID, synchronisation info, GPS 1pps

modulation links modes radio link (HDB3, QPSK) satellite (QPSK) dark fibre ATM over SDH/PDH

7TSP ITU inter-regional seminar 11 DVB-T transmitter monitoring

transmitter RF parameters accuracy of frequency output phase of LO average level and max. peak level in RF and IF amplitude vs frequency phase vs frequency C/N and intermodulation shoulder distance power efficiency

parameters after QPSK/QAM parameters in demodulation 2k/8k mode constellation diagram BER, MER, END TPS signal delay from TS @ transmitter input to antenna

7TSP ITU inter-regional seminar 12 DVB-T Transmitter

switch possition: position 1 exciteroutput BER 2*10-4 nach Viterbi @ Noise 1

position 2 DVB-T transmitteroutput BER 2*10-4 nach Viterbi @ Noise 2 TS transfare via END = Noise 2 - Noise 1 radio link exciter satellite RF output fiber ......

DVB-T demodulator BER measurment 1

2 DVB-T transmitter RF output

7TSP ITU inter-regional seminar 13 DVB-T realisation of digital transmitter stations

Transition from analog to digital

7TSP ITU inter-regional seminar 14 DVB-T realisation of digital transmitter stations

Requirements for the engineering work

Definition of the intended coverage area in relation to the existing analog TV Service (area , population, channel, power).

Investigation of possible limitation by interference of other services in this area

Result: Selection of "free channels" to choose for licensing in terms of frequency and radiated power.

7TSP ITU inter-regional seminar 15 DVB-T realisation of digital transmitter stations

Technical planning of the station

- Investigation of the existing antenna Result: dependent on the desired coverage area (omnidirectional, sectional, beam) and mechanical (static) situation define modification and antenna gain. - Calculate necessary transmitter power - Space requirement for transmitters

7TSP ITU inter-regional seminar 16 DVB-T realisation of digital transmitter stations

Alternativ: transition of the excisting analog transmitter into digital service

- Change of encoder module in exciter

- bypassing of the sound part ( and v/s )

- introducing of DVB-T band - filter

- new equalizing of transmitter

7TSP ITU inter-regional seminar 17 Transmitter DVB-T /Analog(combined)

Block Diagram NH/NV7000

7TSP ITU inter-regional seminar 18 Transmitter analog(split)

synthesizer amplifier VH602

exciter A inputs VF1 VF2 I I vision ATV digital I / Q RF encoder Q precorrector Q modulator AF1 sound AF2 dB

exciter B inputs VF1 integrated power supply

VF2 I I ATV digital I / Q AF1 encoder Q precorrector Q modulator AF2

6 x VH602 synthesizer

harmonic- 10 kW optional filter vision/sound -4,43- lightning diplexer notch filterr protection

7TSP ITU inter-regional seminar 19 DVB-T transmitter NV7000

Block Diagram 1,3 kW DVB-T Transmitter

amplifier VH602

exciter A input ASI

HP1 HP2 I I Encoder digital I / Q RF LP1 DVB-T Q precorrector Q Modulator LP2 dB

exciter B built-in power supply input ASI

HP1 HP2 I I Encoder digital I / Q RF LP1 DVB-T Q precorector Q Modulator LP2 optional

1,3 kW rms

harmonics- channel- lightning- filter filter protection

optional

DVB-T Transmitter

NV7130 1,3kWrms

7TSP ITU inter-regional seminar 20 PAL-nonlinearity

Black picture Black picture

Frequency response in channel bl/wi-amplification

7TSP ITU inter-regional seminar 21 DVB- Transmitter nonlinearity

frequencyresponse Constellation Diagramm 64QAM

7TSP ITU inter-regional seminar 22 DVB-T Crest Faktor

analog digital

Uss / 2 = Us = 6 (ca.) normalised to U rms

U clip in Transmitter

Urms = 1

7TSP ITU inter-regional seminar 23 DVB-T realisation of digital transmitter stations

Example of a radiated signal from a TV station

Mixed Operation Analog / Digital

PAL in adjacent channels

DVB-T DVB-T

10dB/DIV

2MHz/DIV

Interference from analog to digital service Interference from digital to analog service

7TSP ITU inter-regional seminar 24 DVB-T realisation of digital transmitter stations

Transmitter Output Spectral Mask after the Bandpass Filter

Relative Spectral Density (Frequency Response) (dB) +0,5 -4MHz/0,5dB 4MHz/0,5dB

0

-1,0 -3,805MHz/-1,0dB 3,805MHz/-1,0dB

-20 UHF Channel N-1 UHF Channel N UHF Channel N+1

-30 -4,3MHz/-36dB 4,3MHz/-36dB Groupdelay Tg=250ns -40

-10,25..-6MHz/-45dB 6...10,25MHz/-45dB -50 Ref.

-60 Tg=-250ns

-12 -10 -8 -6 -4 -2 F centre 2 4 6 8 10 12

Frequency relative to Multiplex Centre (MHz)

7TSP ITU inter-regional seminar 25 DVB-T realisation of digital transmitter stations

3dB couplers insertion loss / dB narrow band broadband input input

8 cavity filters

output

frequency / MHz

-10 -8 -6 -4 -2 f-center 2 4 6 8 10 MHz

7TSP ITU inter-regional seminar 26 DVB-T realisation of digital transmitter stations

100

90

80

70

60

50

40

30

20

10 Minimum median field strength [dBuV/m] 0

Bitrate [Mbit/s] Tg/Tu = 1/4

FX QPSK FX 16 QAM FX 64 QAM Port A QPSK Port A 16 QAM Port A 64 QAM Port B QPSK Port B 16 QAM Port B 64 QAM

7TSP ITU inter-regional seminar 27 DVB-T realisation of digital transmitter stations

7TSP ITU inter-regional seminar 28 DVB-T realisation of digital transmitter stations

Modulation Code Rate DVB-T net data rates Nutzträger 6048 Takt [MHz] 9 1/7 9 1/7 9 1/7 9 1/7

Guard interv.35 1/4 1/8 1/16 1/32 n*T 8192 8192 8192 8192 Tu [us] 30 896 896 896 896 n*T 2048 1024 512 256 d [us] 25 224 112 56 28 n*T 10240 9216 8704 8448 net 20 Tu+d data[us] 1120 1008 952 924 rates 15 Modulation[Mbps] 64 QAM Bit/Träger 6

Code Rate 10

Guard interv.5 1/4 1/8 1/16 1/32

max. Rate [Mbit/s] 2 1/2 4,98 5,53 5,85 1/32 6,03 0 2 2/3 6,64 7,37 7,81 1/16 8,04 1/2 2/3 3/4 2 2 5/6 7/8 3/4 7,46 8,29 8,78 1/8 guard 9,05 interval 2 2 1/2 2 2 2/3 3/4 4 5/6 7/8 1/4 2 5/6 4 4 8,29 1/2 9,22 9,76 10,05 4 4 2/3 3/4 6 5/6 7/8 2 7/8 8,71 9,686 6 10,25 10,56 code rate of inner error protection / 6 6 bits per sub-carrier max. Rate [Mbit/s] 4 1/2 9,95 11,06 11,71 12,06

7TSP ITU inter-regional seminar 29 DVB-T transmitter system

The new UHF transmitter family NH/NV7000 for analog and digital TV transmitters - High Power -

Innovation and experience for the benefit of the broadcaster

7TSP ITU inter-regional seminar 30 DVB-T transmitter system

NH/NV7000 Component Structure and System Family

Modulator / Exciter SH700 ATV Splitt Ampl. / SC700 ATV Combined Ampl. / SV700 DVB-T

Control and Monitoring

LDMOS Amplifier Modules 470 - 860 MHz VH602 VH650 500W/200W 2kW/400W

Power Supply integrated in VH602 Power Supply

Liquid Cooling System Air Cooling System

High Power Tx Medium Power Tx ATV: 3,5kW ... 40kW ATV: 250W ... 2kW DVB-T: 800W ... 10kW DVB-T: 100W ... 800W

7TSP ITU inter-regional seminar 31 DVB-T transmitter system

TARGETS for NH/NV7000 Transmitter: Medium Power air cooled Transmitter: High Power liquid cooled l Economical l Compact l State of the art l Modular design l Expandable l Easy to handle

7TSP ITU inter-regional seminar 32 DVB-T transmitter system

Liquid Cooled Transmitter / Amplifier

VH602 LDMOS amplifier

10kW ATV / 2,5 kW DVB-T transmitter into one rack

7TSP ITU inter-regional seminar 33 DVB-T transmitter system Overview NV/NH7000

System configuration for liquid cooling

Exciter DVB-T Filter DVB-T Modulator Analog VH602 Harmonics Modulator and Amplifier incl. PS Combiner Trap Filter

Controlling Heat and Pump System Monitoring Exchanger

7TSP ITU inter-regional seminar 34 NH/NV7000 High Power

NH/NV Power Classes

Number of ATV DVB-T

Amplifier Module Psync Peff (36dB shoulder) (+ Sound Amp. Module for ATV)

2 (+1*) 3,5 kW 800 W

3 (+1*) 5 kW 1,3 kW

4 (+2) 7 kW 1,7 kW

6 (+2) 10 kW 2,5 kW

8 (+2) 13 kW 3,4 kW

12 (+2) 20 kW 5 kW

* optional 2 Further combination: 2*13kW and 2*20kW in active reserve 3*10kW 7TSP ITU inter-regional seminar 35 Redundancy in power

Output Power with Breakdown of :

æ ö2 ç m-n ÷ P = P * ç ÷ ç ÷ out rated ç m ÷ è ø

Pout = real output power Prated = nominal output power m = number of amplifiers n = number of defect amplifiers

for example: m=8, n=1 Þ Pout = 0.766 x Prated

7TSP ITU inter-regional seminar 36 VH602 Amplifier and Power Supply

Cooling Concept Amplifier l Closed loop of liquid through one pipe with continuous identical diameter into the amplifier heat sink (corrosion-less material in stainless steel and aluminium) l Internal blower for transfer of remainder heat to watercooler, thus preventing any hot spot l Transistors mounted directly on top of cooling pipe l DT input / output amplifier < 3°C l Junction temperature < 120°C at 24°C ambient temperature

7TSP ITU inter-regional seminar 37 VH602 Amplifier and Power Supply

VH602 Block Diagram

270W PSYNC 65W PDVB 60W 15W analog 2mW 10W 2kW

440W 0,4mW 2W digital

65W 270W 15W 60W

7TSP ITU inter-regional seminar 38 Liquid Cooling System

Water Cooling System for the transmitter NV6000

M

Heat exchanger

T1 P1 P1

Flexi tubing Drain valve

Safety valve Expansion vessel Ball valve Check valve Pump

M 3-way mixer air-vent valve Flow control monitor

7TSP ITU inter-regional seminar 39 Multistandard Exciter SX700

Power supply

ATV/DVB Encoder

Digital Pre-Corrector

Modulator

Synthesizer CCU

7TSP ITU inter-regional seminar 40 Exciter SH/SC/SV700

Block Diagram

TS HP A / VIDEO 1 DVB-Encoder: ATV/DVB-Precorrector: ATV/DVB-Modulator: - MIP-Decoder - Groupdelay Corrector - analogue I/Q-Modulation TS HP B / - SFN Function - Linear Precorrector for into RF for Video and RF_VIDEO VIDEO 2 - Channel Coding I_VIDEO DVB and I_VIDEO Audio Band III, IV and V TS LP A / and Modulation ATV split and combined - Output Filter for Video and VIDEO_MON Q_VIDEO - D/A-Conversion Q_VIDEO Audio or - Output Amplifier TS LP B I_AUDIO I_AUDIO - RF Checker RF_AUDIO ATV-Encoder: Q_AUDIO Q_AUDIO 1PPS_EXT - digital Video- and Audio processing RF_CHECK RS232 - multi Standard Digital Analogue - optional NICAM or Std M Interface Interface RS232_FLASH module (14 Bit)

CONTROL LOCAL

INT_REF (120MHZ) ATV/DVB-Synthesizer: REF_EXT 1PPS INT - 10 MHz local Ref-PLL - Band III, IV and V RS485 - optional internal GPS- module GPS_ANT

RS232 Central Control Unit Displayunit

RS485 RS232 TTL-Bus Control Bus to to Amplifiers, Switches, par. Interface Blowers, ...

7TSP ITU inter-regional seminar 41 Remote interface

NetLink

7TSP ITU inter-regional seminar 42 Remote interface

Monitoring and Controlling System l User-friendly monitoring software on ROHDE&SCHWARZ TRANSMITTER CONTROL UNIT one large display l Additional PC software (GUI) with very comfortable graphical presentation REMOTE CONTROL Signals Parallel Interface I/O Commands and high level of information (Option)

F1 F2 F3 F4 F5

ESCAPE TAB ENTER BITBUS- RS 485 RS 485 Gateway + + + (BITBUS acc.

com 2 l One interface for the all parameters of - + (Option) to IEC 864-2)

+

the exciter (incl. encoder and RESET RS 232 Modem PSTN RS 232 + + + (Option) (TNPP) com 1 com 3 GPS-receiver in case of DVB-T) com 1 com 4 I / O Web-Server/ Ethernet RS 485 SNMP-Agent (Option) (TCP/IP or SNMP) l Multiple possibilities of remote control GUI (Graphical User Interface)

B B SV700 - Bitbus (RS485) Amplifier A RC RS 232

com 1 A SV700 GS (TNPP) RS 232 (SH700) (TNPP)

com 2 com 1 Amplifier - RS232 with TNPP protocol (SC700) RC -> modem option Encoder Equal. Synth. IQ-Mod.

- NetLink for SNMP interface or CCU : Central Control Unit SV700 : Exciter DVB-T SH700 : Exciter Analog-TV (Split) WEB-based supervision system SC700 : Exciter Analog-TV (Combined) RC : Rack Control - Parallel interface

7TSP ITU inter-regional seminar 43 3. NetLink Unit for Remote Control

Overview on Protocol Types and Layers

Web-Browser HP Openview

Application HTTP SNMP (Layer 7) (Hyper Text Transfer Protocol) (Simple Network Management Protocol)

Transport TCP UDP (Layer 4) (Transport Control Protocol) (User Datagram Protocol)

Network IP (Layer 3) (Internet Protocol)

7TSP ITU inter-regional seminar 44 4. NetLink WEB-Server

WEB-Server Application (Supervision System over TCP/IP)

Transmitter Station Network Control Centre / Mobile Staff

• Ethernet (LAN/WAN) Integrated WEB-server Laptop NetLink from R&S with standard WEB-browser

Internet / Intranet (TCP/IP)

Management system Firewall (Windows, Unix, Linux, Mac) with standard Web-browser

Server Client

7TSP ITU inter-regional seminar 45 5. NetLink SNMP-Agent

SNMP Application

Transmitter Stations Network Control centres

R&S delivery part

NetLink Integrated SNMP agent from R&S

• Ethernet (LAN/WAN) Management platform (e.g. HP openview) and SNMP network manager (software) SNMP Network

SNMP agent Tx from Supplier X

Server NMS SNMP Traps

7TSP (Alarms) ITU inter-regional seminar 46 Transmitter Redundency Systems

7TSP ITU inter-regional seminar 47 Dual drive, single PA stage

band pass 3 port U-link PA filter panel TS OFDM RF out antenna Mod.A Exciter A

TVSS D.L.

TS OFDM Mod.B Exciter B

7TSP ITU inter-regional seminar 48 Dual drive, double PA stage, U-link patching

RF U-link patch panel 3 dB coupler PA A TS absorber OFDM Mod.A Exciter A

band pass filter D.L. RF out antenna

TVSS PA B TS OFDM Mod.B Exciter B

7TSP ITU inter-regional seminar 49 Dual drive, double PA stage, RF relay switch

RF relays automatic switching 3 dB coupler PA A TS absorber OFDM Mod.A Exciter A

band pass filter

D.L. RF out antenna

TVSS PA B TS OFDM Mod.B Exciter B

7TSP ITU inter-regional seminar 50 Passive stand-by

band pass PA A filter TS RF relay OFDM RF out antenna Mod.A Exciter A

TVSS

D.L. PA B TS OFDM Mod.B Exciter B

7TSP ITU inter-regional seminar 51 Passive stand-by with dual drive

band pass PA filter TS OFDM RF out antenna Mod.A Exciter A

TVSS

D.L. PA TS OFDM Mod.B Exciter B

7TSP ITU inter-regional seminar 52 Passive-/active stand-by for half antenna

band pass PA A filter TS RF out UA OFDM Mod.A Exciter A absorber TVSS

D.L.

3 dB coupler

PA B TS RF out LA OFDM Mod.B Exciter B

TVSS

7TSP ITU inter-regional seminar 53 Reserve concepts

N+1 Reserve System

CCU

1 2 n R

ASI crossbar switch

Programm 1 Programm 2 Programm n

DVB-T transmitter n+1

7TSP ITU inter-regional seminar 54 Conclusion

Benefits for the broadcaster

þ Extremely compact design þ Improved technology for exciter, amplifier and cooling system þ Low operational cost þ More flexibility for installation þ More flexibility for remote control þ High commonality of sub-modules for reduced spares inventories þ Easy transition from analogue to digital secures investment

7TSP ITU inter-regional seminar 55 References:

ETS 300 744 Digital Video (DVB); Framing structure, channel coding and modulation for digital Terrestrial (DVB-T).

ETR 290 Digital Video Broadcasting (DVB); Measurement guidelines for DVB systems.

TR 101 190 Digital Video Broadcasting (DVB); Implementation guidelines for DVB terrestrial services; Transmission aspects. (TR 101 190).

TM 1925 Digital TV Transmitter Performance Specification. (AC106 VALIDATE Del.14)