Sentino® Filter Funnel Sentino ® Filter Funnel Convenient and reliable filter funnel for Microbiology Monitoring of aqueous solutions The Sentino Filter Funnel is a reliable and easy-to- Risk Reduction - The Sentino Filter Funnel and use, disposable device for the microbial monitoring Pall Membranes reduce the risk of a contami- of aqueous solutions. Combined with the Sentino nation event as compared to reusable funnels. Dispenser Packs or the S-Pack Membrane Disc The filter funnels are pre-sterilized via Gamma Filters, the risk of a contamination event is drastically Sterilization eliminating the need for autoclaving reduced over reusable devices as a new funnel and or any other cleaning/sanitizing techniques. membrane are used for each sample. This will save time and money by eliminating the need to investigate contamination events Composed of Polypropylene plastic, the filter resulting from the reusable devices. funnels are molded with the graduations on the outside of the funnel eliminating the possibility Regulatory Compliance - Membrane filtration of solution being held up in the grooves of the is the method of choice for Microbial Monitoring graduations ensuring that all the solution passes of aqueous solutions as specified in "Standard through the membrane filter disc. The filter funnels Methods for the Examination of Water and are available in both 100 mL and 250 mL capacity Wastewater" and Pharmacopoeias worldwide. to accommodate a wide variety of solution volumes . Easy-to-Use - The Sentino Filter Funnel and Adaptor are designed with a press-fit seal, membrane guides and forceps access point allowing for simple set up and membrane removal. This will speed up the process time in the laboratory. Applications Ordering Information Disposable filter funnel cylinders used with individual discs Sentino Filter Funnel of membrane are a cost-effective, time saving option for VWR Pall testing of aqueous samples for organism contamination using Cat. No. Part No. Description Pkg Membrane Filtration. The Sentino Filter Funnel is designed 10147-760 4870 100 mL, 25/sleeve 100/pkg for use with the Sentino Microbiology System or a manifold for microbial monitoring. 10147-762 4871 250 mL, 20/sleeve 80/pkg Accessories Beverage monitoring VWR Pall Drinking and wastewater analysis Cat. No. Part No. Description Pkg Environmental and recreational water monitoring 30617-194 4285 Tubing for Sentino Microbiology 10/pkg Pump, 61 cm (24 in.) length Personal care product Quality Control 10147-386 4872 Sentino Filter Funnel adapter, stainless 1/pkg Pharmaceutical Quality Control steel for Sentino Microbiology Pump 10147-388 4873 Sentino Filter Funnel adapter, stainless 3/pkg steel for standard manifold Specifications 10147-390 4874 Aluminum manifold, 3-place for use 1/pkg with Sentino Filter Funnel Materials of Construction 10147-392 4875 Aluminum manifold, 6-place for use 1/pkg Funnel: Polypropylene with Sentino Filter Funnel Dimensions 100 mL Diameter: 8.1 cm (3.2 in) Complimentary Products Height: 5.3 cm (2.1 in) Sentino Microbiology Pump — Maximize workspace and 250 mL minimize contamination risk with this unique, portable pump Diameter: 8.1 cm (3.2 in) for microbiological analysis Height: 9.6 cm (3.8 in) Sentino Filter Dispenser — Offers easy membrane loading Gamma-Irradiated with no jamming Validated dose 15-30 kGy Ampoule Media for Microbiological Analysis – Wide Effective Filtration Area variety of sterile ampoule media pre-measured for ease of use 12.5 cm² Petri Dishes − Unique design for easy handling, stacking, and storage Stainless Steel Forceps – Makes membrane handling easy Ordering: www.vwr.com Technical Assistance: [email protected] Product Support: www.pall.com/lab © 2015, Pall Corporation. Pall, , and Sentino are trademarks of Pall Corporation. ® indicates a trademark registered in the USA. Filtration. Separation. Solution. is a service mark of Pall Corporation. 4/15, PDF, GN14.8806US 1014 Lit. No. 161136W .
Recommended publications
  • Funnels and Filters
    51 FUNNELS AND FILTERS Buchner Funnels 260MM (10.25") INSIDE DIAMETER, 203MM (8") OVERALL HEIGHT, 127MM (5") RIM TO PLATE CATALOG NO. DESCRIPTION PRICE/EACH H14620-0000 Funnel with Coarse Porosity Fixed Plate $216.00 H14620-1260 Funnel with Coarse Porosity Removable Plate 216.00 H14625-3510 Funnel with Medium Porosity Fixed Plate 216.00 H14626-3510 Funnel with Medium Porosity Removable Plate 216.00 H14627-0000 Funnel with Perforated Fixed Plate 216.00 Table-Top H14627-1260 Funnel with Perforated Removable Plate 216.00 Buchner 457MM (18") INSIDE DIAMETER, 292MM (11.5") OVERALL HEIGHT, 203MM (8") RIM TO PLATE Funnels CATALOG NO. DESCRIPTION PRICE/EACH With Fritware® Porous H14621-0000 Funnel with Coarse Porosity Fixed Plate $540.00 Filter or HDPE H14621-1457 Funnel with Coarse Porosity Removable Plate 540.00 H14625-3518 Funnel with Medium Porosity Fixed Plate 540.00 Perforated Plate H14626-3518 Funnel with Medium Porosity Removable Plate 540.00 Polyethylene funnels are H14628-0000 Funnel with Perforated Fixed Plate 465.00 one piece design with a H14627-1457 Funnel with Perforated Removable Plate 465.00 FIXED or REMOVABLE Custom sizes available upon request. 610MM (24") INSIDE DIAMETER, 330MM (13") OVERALL HEIGHT, 267MM (10.25") RIM TO PLATE porous filter plate CATALOG NO. DESCRIPTION PRICE/EACH supported by a multiple ring grid. Filter plates are made of high density H14622-0000 Funnel with Coarse Porosity Fixed Plate $1125.00 1 polyethylene 6.4mm ( ⁄4") thick with a non-porous ring at the periphery of the plate H14622-1610 Funnel with Coarse Porosity Removable Plate 1125.00 1 H14625-3524 Funnel with Medium Porosity Fixed Plate 1125.00 which seals filter paper when used.
    [Show full text]
  • Laboratory Equipment Reference Sheet
    Laboratory Equipment Stirring Rod: Reference Sheet: Iron Ring: Description: Glass rod. Uses: To stir combinations; To use in pouring liquids. Evaporating Dish: Description: Iron ring with a screw fastener; Several Sizes Uses: To fasten to the ring stand as a support for an apparatus Description: Porcelain dish. Buret Clamp/Test Tube Clamp: Uses: As a container for small amounts of liquids being evaporated. Glass Plate: Description: Metal clamp with a screw fastener, swivel and lock nut, adjusting screw, and a curved clamp. Uses: To hold an apparatus; May be fastened to a ring stand. Mortar and Pestle: Description: Thick glass. Uses: Many uses; Should not be heated Description: Heavy porcelain dish with a grinder. Watch Glass: Uses: To grind chemicals to a powder. Spatula: Description: Curved glass. Uses: May be used as a beaker cover; May be used in evaporating very small amounts of Description: Made of metal or porcelain. liquid. Uses: To transfer solid chemicals in weighing. Funnel: Triangular File: Description: Metal file with three cutting edges. Uses: To scratch glass or file. Rubber Connector: Description: Glass or plastic. Uses: To hold filter paper; May be used in pouring Description: Short length of tubing. Medicine Dropper: Uses: To connect parts of an apparatus. Pinch Clamp: Description: Glass tip with a rubber bulb. Uses: To transfer small amounts of liquid. Forceps: Description: Metal clamp with finger grips. Uses: To clamp a rubber connector. Test Tube Rack: Description: Metal Uses: To pick up or hold small objects. Beaker: Description: Rack; May be wood, metal, or plastic. Uses: To hold test tubes in an upright position.
    [Show full text]
  • Portable Fluid Analysis Kit Manual
    Donaldson Delivers Portable Fluid Analysis Kit Patch Test Kit Manual Kit Part Number X009329 Carrying Case Membrane Holder & Funnel Assembly P567863 Filter for Solvent Dispensing Bottle P567860 (Qty. 3) 500 ml Solvent Sampling Dispensing Bottle Pump P176431 Microscope 120 ml P567864 Sample Bottles (Qty. 6) Plastic Tubing P567861 (5 ft.) 1.2 micron Patch Covers Membrane P567912 (Qty. 150) Filters P567869 Zip Drive of (Qty. 100) Reference Information Membrane Filter Forceps Sharpie Analysis Cards (3”x5”) P567865 (Qty. 50) 5 micron Membrane Filters Marker P567868 (Qty. 50) Case Size: Height: 14.5”/368.3mm | Width: 19.25”/489mm | Depth: 7.75”/197mm | Case Weight: 9.95 lbs./4.51 kg 1 2 3 Assemble waste bottle, funnel- Install solvent* dispensing tube and Rinse the funnel-patch assembly patch assembly, and vacuum pump install solvent filter on end of the with the filtered solvent to remove to form the sample processing dispensing tube. background contamination. The assembly. Tighten the vacuum patch should not be in place for pump o-ring on the funnel-patch * Mineral spirits are the most this process. assembly tube by turning the commonly used solvent aluminum locking device. 2 • www.donaldson.com Patch Test Kit Manual 4 5 6 Separate the funnel from the patch Reattach the funnel to the filter Agitate the sample fluid bottle and supporter and install a filter patch patch base with filter patch. Twist pour 25ml into the funnel. 25ml with ink grid up. (If the patch has an lock the funnel to the base. is denoted by the first line on the ink grid) funnel (closest to the patch).
    [Show full text]
  • Marsh Funnel
    Marsh Funnel Summary: The Marsh Funnel was developed to provide a field measurement of the apparent viscosity of clay-thickened drilling mud. Provided that a conversion table has been developed, a modified Marsh Funnel can be used to provide a measure of apparent viscosities for gum-thickened and polymer- thickened products used in wildland fire operations. Without a conversion table, the flow-through times can be used to determine batch to batch consistency of a single product, and in limited circumstances to compare similar products. The directions for use of a Marsh Funnel are given below. The procedures for modifying the Marsh Funnel for use in determining the viscosity of long-term retardants (Forest Service modification) and the consistency of water enhancers (California Department of Forestry and Fire Protection, CDF modification) are provided in the following pages. Materials: Marsh Funnel (Use small tip, 3/16” diameter, for low-viscosity products such as Phos-Chek 259 or Phos-Chek LC-95A. Use the large tip, 17/64” diameter, for high- viscosity products such as Phos-Chek D75.) Container marked to 1 quart, a tall straight-sided container is best Stopwatch or timer with a “time up” function Thermometer Method: 1. Allow the test sample to stand until it reaches room temperature (70°F) and all air bubbles are dissipated since both of these factors have an influence on viscosity. 2. Ensure that the properly modified funnel is clean and dry and secured in an upright position (a ring stand works fine). 3. Cover the funnel orifice with a finger while pouring the test sample through the screen until the sample exactly reaches the bottom of the screen.
    [Show full text]
  • Laboratory Supplies and Equipment
    Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout
    [Show full text]
  • Ultraviolet – Visible Spectroscopy for Determination of Α- and Β- Acids in Beer Hops
    Isabella Pinque Chem219 Page 1 UV-Vis Spectrophotometric Analysis of Beer Hops date: 3/14/2018 Ultraviolet – Visible Spectroscopy For Determination of α- and β- acids in beer hops Isabella Pinque Lab Partner: Lucas Paquin TA: Kevin Fischer Date lab performed: 02/06/2018 Date report submitted: 03/14/2018 Isabella Pinque Chem 219 page 1 UV-Vis Spectrophotometric Analysis of Beer Hops date: 3/14/2018 ABSTRACT A spectrophotometric analysis at three wavelengths was used to determine the concentration of α-acids, β-acids, and a third component that is associated with the degradation of hops. Two different samples of a simple extraction of hops were analyzed using a Shimadzu UV2450 to determine the concentration of each component. While doing a three component analysis, the third break down component had the highest concentration within the hops sample (0.05391 g/L ± 0.00493) , followed by the α-acids (0.01507 g/L ± 0.001291) and finally β-acids (0.005062 ± 0.0004816). When doing a two component analysis, the α-acid had a higher concentration than the β-acids, 0.01783 ± 0.001539 and 0.004354 ± 0.0004520, respectively. When taking the percentage of all three components, the overall percent did not add up to 1 due to the fact that there are more than just three components in the samples. In conclusion, the α-acids are more prevalent in a sample of hops which can be taken into consideration when home brewing to achieve the bitterness and the flavor desired. INTRODUCTION Hops are an essential aspect of the brewing process that provide flavor and aromas due to the oils and resins that reside in the lupulin glands of a hops cone (1).
    [Show full text]
  • Funnels and Filters
    Funnels And Filters table-top Buchner A B Funnels Filter Large Volumes Quickly Polyethylene funnels with your choice of Fritware® or Perforated filter plate. Removable 1 hose barbed connector accepts 12.7mm ( ⁄2") 3 I.D. tube and threads into ⁄4" NPT bung on the funnel. A. Fritware® Porous Filter Plates FIXED or REMOVABLE porous filter plate supported by a multiple ring grid. Filter plates are made of high density polyethylene, 1 6.4mm ( ⁄4") thick, with a non-porous ring at the periphery of the plate which seals filter paper when used. Available in two porosities (medium and coarse). Medium porosity plate is 45-90 microns; coarse porosity plate is 90-130 Custom sizes available upon request. microns. Use below 52ºC (125ºF). B. Perforated Filter Plates 3 Available with a FIXED or REMOVABLE perforated filter plate made of 4.8mm ( ⁄16") thick high 3 7 density polyethylene (HDPE) with 4.8mm ( ⁄16") perforations on 11mm ( ⁄16") centers. The FIXED version is for coarse filtration or use with a cloth or paper filter. A REMOVABLE filter plate is available for use in precious metals recovery. Use below 52ºC (125ºF). Large diameter 24" and 36" sizes (next page) are crated for shipment. Buchner table-top Funnels 10.25” (26cm) Funnel Inside Diameter 8" (20.3Cm) Overall HeIgHt, 5” (12.7Cm ) rIm tO Plate CatalOg nO. I.D. DesCrIPtIOn H14620-0000 10.25" Funnel with Coarse Porosity Fixed Plate (A) H14620-1260 10.25" Funnel with Coarse Porosity Removable Plate (A) H14625-3510 10.25" Funnel with Medium Porosity Fixed Plate (A) H14626-3510 10.25" Funnel with Medium Porosity Removable Plate (A) H14627-0000 10.25" Funnel with Perforated Fixed Plate (B) H14627-1260 10.25" Funnel with Perforated Removable Plate (B) 18" (45.7cm) Funnel Inside Diameter 11.5" (29.2Cm) Overall HeIgHt, 8" (20.3Cm) rIm tO Plate CatalOg nO.
    [Show full text]
  • Laboratory Equipment Used in Filtration
    KNOW YOUR LAB EQUIPMENTS Test tube A test tube, also known as a sample tube, is a common piece of laboratory glassware consisting of a finger-like length of glass or clear plastic tubing, open at the top and closed at the bottom. Beakers Beakers are used as containers. They are available in a variety of sizes. Although they often possess volume markings, these are only rough estimates of the liquid volume. The markings are not necessarily accurate. Erlenmeyer flask Erlenmeyer flasks are often used as reaction vessels, particularly in titrations. As with beakers, the volume markings should not be considered accurate. Volumetric flask Volumetric flasks are used to measure and store solutions with a high degree of accuracy. These flasks generally possess a marking near the top that indicates the level at which the volume of the liquid is equal to the volume written on the outside of the flask. These devices are often used when solutions containing dissolved solids of known concentration are needed. Graduated cylinder Graduated cylinders are used to transfer liquids with a moderate degree of accuracy. Pipette Pipettes are used for transferring liquids with a fixed volume and quantity of liquid must be known to a high degree of accuracy. Graduated pipette These Pipettes are calibrated in the factory to release the desired quantity of liquid. Disposable pipette Disposable transfer. These Pipettes are made of plastic and are useful for transferring liquids dropwise. Burette Burettes are devices used typically in analytical, quantitative chemistry applications for measuring liquid solution. Differing from a pipette since the sample quantity delivered is changeable, graduated Burettes are used heavily in titration experiments.
    [Show full text]
  • Methods and Techniques for Nematology
    METHODS AND TECHNIQUES FOR NEMATOLOGY By J. van Bezooijen Revised version 2006 PREFACE This Manual ‘Methods and Techniques for Nematology’ is based on the ‘Manual for Practical Work in Nematology’ (s’Jacob & van Bezooijen 1984), which has been thoroughly revised. The ‘Practicumhandleiding Nematologie’ (van Bezooijen & Ettema 1996) was the basis for even further revision. The final product, which you will be using now, does not pretend to be complete, but is an augmented and in many parts corrected version of the earlier manuals. The author is greatly indebted to A. Raeymaekers for preparing the final layout and for her useful proposals to increase the readability. Her impressive computer skills contributed substantially to a higher quality of the book. Additional improvements and corrections may remain necessary and the author welcomes any comments and suggestions. In spite of this, hopefully this manual will be useful to you Wageningen, December 2006 CONTENT PREFACE CONTENT CHAPTER 1. SAMPLING 2 1.1. PRACTICAL AND THEORETICAL CONSIDERATIONS 2 1.1.1. Purpose and accuracy of sampling 2 1.1.2. Variation in space: horizontal and vertical 2 1.1.3. Variation in time: seasonal fluctuations and life cycles 3 1.1.4. Statistics 3 1.2. THE SAMPLING PROCESS 4 1.2.1. Tools 4 1.2.2. Sampling patterns 5 1.2.3. Examples of sampling methods 5 1.3. TRANSPORT AND STORAGE 8 1.3.1. Fixing samples in the field 8 1.4. PRE-PROCESSING OF THE SAMPLE 8 1.4.1. Measuring: volume or weight? 8 1.4.2. Taking sub-samples; Mixing 9 1.4.3.
    [Show full text]
  • Sentino™ Magnetic Filter Funnels
    Sentino™ Magnetic Filter Funnels Designed for Use with the New Sentino Microbiology Pump Variety of sizes – Available in 150, 300, and Applications 500 mL. Convenient 150 mL size easily fits into small autoclaves; 500 mL size is ideal for large Drinking and waste water analysis sample filtration. Environmental and recreational water monitoring Easy to use – No-leak magnetic seal allows Pharmaceutical and industrial water system one-handed operation. monitoring Safe to use – Sturdy, polyphenylsulfone plastic Beverage monitoring construction is shatterproof and offers broad range of chemical compatibility. Pharmaceutical raw materials, intermediates, and final product Simple placement – Membrane guides help center filter on platform. Quick point of entry – Forceps access point allows easy filter retrieval. Accurate – Graduated at 50 mL increments for precise sample measurement. Specifications Related Products Materials of Construction Sentino Microbiology Pump Funnel Body, Stem, Lid, and Support Screen: Polyphenylsulfone Standard 47 mm magnetic filter funnels Vent Plugs: Polypropylene Ampoule Media for Microbiological Analysis Effective Filtration Area 150 and 300 mL: 9.6 cm2, 35 mm effective diameter Stainless Steel Forceps 500 mL: 13.1 cm2, 41 mm effective diameter Sterile Petri Dishes Dimensions Height: Ordering Information 150 mL: 11.8 cm (4.6 in.) 300 mL: 16.8 cm (6.6 in.) Sentino Magnetic Filter Funnels 500 mL: 16.6 cm (6.5 in.) VWR Pall Cat. No. Part No. Description Pkg Maximum Diameter: 150 and 300 mL: 7.6 cm (3 in.) 30617-184 4271 47 mm, 150 mL capacity 1/pkg 500 mL: 8.9 cm (3.5 in.) 30617-186 4273 47 mm, 300 mL capacity 1/pkg 30617-188 4277 47 mm, 500 mL capacity 1/pkg Filter Size Accepts 47 mm filter Accessories and Replacements Parts Funnel Capacity VWR Pall 150, 300, or 500 mL Cat.
    [Show full text]
  • Laboratory Equipment AP
    \ \\ , f ?7-\ Watch glass 1 Crucible and cover Evaporating dish Pneumatlo trough Beaker Safety goggles Florence Wide-mouth0 Plastic wash Dropper Funnel flask collecting bottle pipet Edenmeyer Rubber stoppers bottle flask € ....... ">. ÿ ,, Glass rod with niohrome wire Scoopula (for flame re,sting) CruoiNe tongs Rubber ubing '1 ,v .... Test-tube brush square Wire gau ÿ "\ file Burner " Tripod Florence flask: glass; common sizes are 125 mL, 250 mL, 500 .d Beaker: glass or plastic; common sizes are 50 mL, mL; maybe heated; used in making and for storing solutions. 100 mL, 250 mL, 400 mL; glass beakers maybe heated. oÿ Buret: glass; common sizes are 25 mL and 50 mL; used to Forceps: metal; used to hold or pick up small objects. Funnel: glass or plastic; common size holds 12.5-cm diameter measure volumes of solutions in titrafions. Ceramic square: used under hot apparatus or glassware. filter paper. Gas burner: constructed of metal; connected to a gas supply Clamps" the following types of clamps may be fastened to with rubber tubing; used to heat chemicals (dry or in solution) support apparatus: buret/test-tube clamp, clamp holder, double buret clamp, ring clamp, 3-pronged jaw clamp. in beakers, test tubes, and crucibles. Gas collecting tube: glass; marked in mL intervals; used to 3: Clay triangle: wire frame with porcelain supports; used to o} support a crucible. measure gas volumes. Glass rod with nichrome wire: used in flame tests. Condenser: glass; used in distillation procedures. Q. Crucible and cover: porcelain; used to heat small amounts of Graduated cylinder: glass or plastic; common sizes are 10 mL, 50 mL, 100 mL; used to measure approximate volumes; must solid substances at high temperatures.
    [Show full text]
  • A Modified Device for Rapid Selection of Soil and Water Nematodes from Mixed Suspension
    Nematol. medit. (1976), 4: 245-247. I Section of Plant Pathology and Nematology, Department of Botany, Aligarh Muslim University, Aligarh-202001, India A MODIFIED DEVICE FOR RAPID SELECTION OF SOIL AND WATER NEMATODES FROM MIXED SUSPENSION by M.M. ALAM An earlier device (Alam, 1975) for selectively picking up large number of soil or fresh water nematodes was modified and appears to be an improvement over similar devices (Minteer, 1965; Shukla et aI., 1971; Khan et al., 1972) because of its speed and semplicity. The entire apparatus can be easily assembled in any laboratory and does not require any specialised components. Assembley and opera­ tion details are as follows: Construction details: Two L-shaped glass tubes (0.5 cm dia­ meter) of 4 and 5 cm lengths were inserted into the neck of a sepa­ rating funnel 'D' (l00 ml capacity) with the help of an air tight rubber stopper. One of the L-shaped tubes (5 cm length) was con­ nected through a rubber tubing (75 cm length, 0.5 cm diameter) to anoter glass tube' E' (15 cm length, 0.7 cm diameter) which was provided with a fine tip (7 cm length). The other L-shaped tube (4 cm length) was connected through a rubber tubing (0.5 cm diameter) of desirable length, to an aspirator' B ' (syn. filter pump) which was attached to a water tap' A'. The separating funnel was supported by a retort stand ' C' (Fig. 1). Operation: Before use, the stopper of the separating funnel , D' was closed and then the water tap 'A' was opened to start suction of air into the aspirator' B' resulting in a partial vacuum in the separating funnel' D '.
    [Show full text]