Microfluidic Droplet Dye Laser Based on a Fabry-Perot Cavity G
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
An Application of the Theory of Laser to Nitrogen Laser Pumped Dye Laser
SD9900039 AN APPLICATION OF THE THEORY OF LASER TO NITROGEN LASER PUMPED DYE LASER FATIMA AHMED OSMAN A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Physics. UNIVERSITY OF KHARTOUM FACULTY OF SCIENCE DEPARTMENT OF PHYSICS MARCH 1998 \ 3 0-44 In this thesis we gave a general discussion on lasers, reviewing some of are properties, types and applications. We also conducted an experiment where we obtained a dye laser pumped by nitrogen laser with a wave length of 337.1 nm and a power of 5 Mw. It was noticed that the produced radiation possesses ^ characteristic^ different from those of other types of laser. This' characteristics determine^ the tunability i.e. the possibility of choosing the appropriately required wave-length of radiation for various applications. DEDICATION TO MY BELOVED PARENTS AND MY SISTER NADI A ACKNOWLEDGEMENTS I would like to express my deep gratitude to my supervisor Dr. AH El Tahir Sharaf El-Din, for his continuous support and guidance. I am also grateful to Dr. Maui Hammed Shaded, for encouragement, and advice in using the computer. Thanks also go to Ustaz Akram Yousif Ibrahim for helping me while conducting the experimental part of the thesis, and to Ustaz Abaker Ali Abdalla, for advising me in several respects. I also thank my teachers in the Physics Department, of the Faculty of Science, University of Khartoum and my colleagues and co- workers at laser laboratory whose support and encouragement me created the right atmosphere of research for me. Finally I would like to thank my brother Salah Ahmed Osman, Mr. -
Self Amplified Lock of a Ultra-Narrow Linewidth Optical Cavity
Self Amplified Lock of a Ultra-narrow Linewidth Optical Cavity Kiwamu Izumi,1, ∗ Daniel Sigg,1 and Lisa Barsotti2 1LIGO Hanford Observatory, PO Box 159 Richland, Washington 99354, USA 2LIGO laboratory, Massachusetts Institute of Technology, Cambridge, Massachussetts 02139, USA compiled: January 8, 2016 High finesse optical cavities are an essential tool in modern precision laser interferometry. The incident laser field is often controlled and stabilized with an active feedback system such that the field resonates in the cavity. The Pound-Drever-Hall reflection locking technique is a convenient way to derive a suitable error signal. However, it only gives a strong signal within the cavity linewidth. This poses a problem for locking a ultra-narrow linewidth cavity. We present a novel technique for acquiring lock by utilizing an additional weak control signal, but with a much larger capture range. We numerically show that this technique can be applied to the laser frequency stabilization system used in the Laser Interferometric Gravitational-wave Observatory (LIGO) which has a linewidth of 0.8 Hz. This new technique will allow us to robustly and repeatedly lock the LIGO laser frequency to the common mode of the interferometer. OCIS codes: (140.3425), (140.3410) http://dx.doi.org/10.1364/XX.99.099999 High finesse optical cavities have been an indispens- nonlinear response [8, 9] dominant and thus hinder the able tool for precision interferometry to conduct rela- linear controller. tivistic experiments such as gravitational wave detection Gravitational wave observatories deploy kilometer [1{3] and optical clocks [4]. The use of a high finesse cav- scale interferometers with extremely narrow linewidth. -
PG0308 Pulsed Dye Laser Therapy for Cutaneous Vascular Lesions
Pulsed Dye Laser Therapy for Cutaneous Vascular Lesions Policy Number: PG0308 ADVANTAGE | ELITE | HMO Last Review: 09/22/2017 INDIVIDUAL MARKETPLACE | PROMEDICA MEDICARE PLAN | PPO GUIDELINES This policy does not certify benefits or authorization of benefits, which is designated by each individual policyholder contract. Paramount applies coding edits to all medical claims through coding logic software to evaluate the accuracy and adherence to accepted national standards. This guideline is solely for explaining correct procedure reporting and does not imply coverage and reimbursement. SCOPE X Professional _ Facility DESCRIPTION Port-wine stains (PWS) are a type of vascular lesion involving the superficial capillaries of the skin. At birth, the lesions typically appear as flat, faint, pink macules. With increasing age, they darken and become raised, red-to- purple nodules and papules in adults. Congenital hemangiomas are benign tumors of the vascular endothelium that appear at or shortly after birth. Hemangiomas are characterized by rapid proliferation in infancy and a period of slow involution that can last for several years. Complete regression occurs in approximately 50% of children by 5 years of age and 90% of children by 9 years of age. The goals of pulsed dye laser (PDL) therapy for cutaneous vascular lesions, specifically PWS lesions and hemangiomas, are to remove, lighten, reduce in size, or cause regression of the lesions to relieve symptoms, to alleviate or prevent medical or psychological complications, and to improve cosmetic appearance. This is accomplished by the preferential absorption of PDL energy by the hemoglobin within these vascular lesions, which causes their thermal destruction while sparing the surrounding normal tissues. -
Power Build-Up Cavity Coupled to a Laser Diode
I POWER BUILD-UP CAVITY COUPLED I TO A LASER DIODE Daniel J. Evans I Center of Excellence for Raman Technology University of Utah I Abstract combination of these elements will emit photons at different frequencies. The ends of these semiconductor In many Raman applications there is a need to devices are cleaved to form mirrors that bounce the I detect gases in the low ppb range. The desired photons back and forth within the cavity. The photons sensitivity can be achieved by using a high power laser excite more electrons, which form more photons source in the range of tens of watts. A system (referred to as optical pumping). 2 A certain portion of I combining a build-up cavity to enhance the power and the photons emit through the front and back cleaved an external cavity laser diode setup to narrow the surfaces of the laser diode. The amount of photons that bandwidth can give the needed power to the Raman get through the cleaved surfaces can be adjusted by I spectroscopy system. coating the surface or installing other mirrors. Introduction to Laser Diodes The planar cleaved surfaces of the laser diode form a Fabry-Perot cavity with set resonance frequencies I An important characteristic of all lasers is the (vp).3 The typical laser diode has a spacing of 150 f.1I11 mode structure. The mode structure refers to both the with an index of refraction of 3.5, yielding a resonance lasing frequency and the spatial characteristics of the frequency of 285 GHz. The wavelength spacing (~A.) I laser. -
Quantum Illumination at the Microwave Wavelengths
Quantum Illumination at the Microwave Wavelengths 1 2 3 4 5 6, Shabir Barzanjeh, Saikat Guha, Christian Weedbrook, David Vitali, Jeffrey H. Shapiro, and Stefano Pirandola ∗ 1Institute for Quantum Information, RWTH Aachen University, 52056 Aachen, Germany 2Quantum Information Processing Group, Raytheon BBN Technologies, Cambridge, Massachusetts 02138, USA 3QKD Corp., 60 St. George St., Toronto, M5S 3G4, Canada 4School of Science and Technology, University of Camerino, Camerino, Macerata 62032, Italy 5Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA 6Department of Computer Science & York Centre for Quantum Technologies, University of York, York YO10 5GH, United Kingdom Quantum illumination is a quantum-optical sensing technique in which an entangled source is exploited to improve the detection of a low-reflectivity object that is immersed in a bright thermal background. Here we describe and analyze a system for applying this technique at microwave frequencies, a more appropriate spectral region for target detection than the optical, due to the naturally-occurring bright thermal background in the microwave regime. We use an electro-opto- mechanical converter to entangle microwave signal and optical idler fields, with the former being sent to probe the target region and the latter being retained at the source. The microwave radiation collected from the target region is then phase conjugated and upconverted into an optical field that is combined with the retained idler in a joint-detection -
Construction of a Flashlamp-Pumped Dye Laser and an Acousto-Optic
; UNITED STATES APARTMENT OF COMMERCE oUBLICATION NBS TECHNICAL NOTE 603 / v \ f ''ttis oi Construction of a Flashlamp-Pumped Dye Laser U.S. EPARTMENT OF COMMERCE and an Acousto-Optic Modulator National Bureau of for Mode-Locking Iandards — NATIONAL BUREAU OF STANDARDS 1 The National Bureau of Standards was established by an act of Congress March 3, 1901. The Bureau's overall goal is to strengthen and advance the Nation's science and technology and facilitate their effective application for public benefit. To this end, the Bureau conducts research and provides: (1) a basis for the Nation's physical measure- ment system, (2) scientific and technological services for industry and government, (3) a technical basis for equity in trade, and (4) technical services to promote public safety. The Bureau consists of the Institute for Basic Standards, the Institute for Materials Research, the Institute for Applied Technology, the Center for Computer Sciences and Technology, and the Office for Information Programs. THE INSTITUTE FOR BASIC STANDARDS provides the central basis within the United States of a complete and consistent system of physical measurement; coordinates that system with measurement systems of other nations; and furnishes essential services leading to accurate and uniform physical measurements throughout the Nation's scien- tific community, industry, and commerce. The Institute consists of a Center for Radia- tion Research, an Office of Measurement Services and the following divisions: Applied Mathematics—Electricity—Heat—Mechanics—Optical Physics—Linac Radiation 2—Nuclear Radiation 2—Applied Radiation 2—Quantum Electronics 3— Electromagnetics 3—Time and Frequency 3 —Laboratory Astrophysics3—Cryo- 3 genics . -
Ophthalmic Laser Therapy: Mechanisms and Applications
1 Ophthalmic Laser Therapy: Mechanisms and Applications Daniel Palanker Department of Ophthalmology and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA Definition The term LASER is an abbreviation which stands for Light Amplification by Stimulated Emission of Radiation. The laser is a source of coherent, directional, monochromatic light that can be precisely focused into a small spot. The laser is a very useful tool for a wide variety of clinical diagnostic and therapeutic procedures. Principles of Light Emission by Lasers Molecules are made up of atoms, which are composed of a positively charged nucleus and negatively charged electrons orbiting it at various energy levels. Light is composed of individual packets of energy, called photons. Electrons can jump from one orbit to another by either, absorbing energy and moving to a higher level (excited state), or emitting energy and transitioning to a lower level. Such transitions can be accompanied by absorption or spontaneous emission of a photon. “Stimulated Emission” is a process in which photon emission is stimulated by interaction of an atom in excited state with a passing photon. The photon emitted by the atom in this process will have the same phase, direction of propagation and wavelength as the “stimulating photon”. The “stimulating photon” does not lose energy during this interaction- it simply causes the emission and continues on, as illustrated in Figure 1. Figure 1: LASER: Light Amplification by Stimulated Emission of Radiation For such stimulated emission to occur more frequently than absorption (and hence result in light amplification), the optical material should have more atoms in excited state than in a lower state. -
Generation of a Flat-Top Laser Beam for Gravitational Wave Detectors By
Generation of a flat-top laser beam for gravitational wave detectors by means of a nonspherical Fabry–Perot resonator Marco G. Tarallo,1,2,* John Miller,2,3 J. Agresti,1,2 E. D’Ambrosio,2 R. DeSalvo,2 D. Forest,4 B. Lagrange,4 J. M. Mackowsky,4 C. Michel,4 J. L. Montorio,4 N. Morgado,4 L. Pinard,4 A. Remilleux,4 B. Simoni,1,2 and P. Willems2 1Dipartimento di Fisica, Università di Pisa, Largo Pontecorvo 3, 56100 Pisa, Italy 2LIGO Laboratory, California Institute of Technology, 1200 E. California Boulevard, Pasadena, California, USA 3Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ, UK 4Laboratoire des Matèriaux Avancès, 22 Boulevard Niels Bohr, Villeurbanne, France *Corresponding author: [email protected] Received 23 February 2007; revised 6 July 2007; accepted 11 July 2007; posted 13 July 2007 (Doc. ID 80265); published 7 September 2007 We have tested a new kind of Fabry–Perot long-baseline optical resonator proposed to reduce the thermal noise sensitivity of gravitational wave interferometric detectors—the “mesa beam” cavity—whose flat top beam shape is achieved by means of an aspherical end mirror. We present the fundamental mode intensity pattern for this cavity and its distortion due to surface imperfections and tilt misalignments, and contrast the higher order mode patterns to the Gauss–Laguerre modes of a spherical mirror cavity. We discuss the effects of mirror tilts on cavity alignment and locking and present measurements of the mesa beam tilt sensitivity. © 2007 Optical Society of America OCIS codes: 140.4780, 120.2230, 230.0040. -
Development of the LDS698 Solid Dye Laser for High Durability
Transactions of the Korean Nuclear Society Spring Meeting Chuncheon, Korea, May 25-26 2006 Development of the LDS698 Solid Dye Laser for High Durability Ji-Hun Kim, Chan-Ju Lim, Sang-Beom Joa and Heon-Ju Lee Faculty of Mechanical & Energy System Engineering, Cheju National Univ., 1 Ara-1 Dong, Jeju-Do, Korea [email protected] 1. Introduction grazing incidence configuration with an incident angle of 11.4°. The reflectivity of the rear mirror is 99% and It is essential to use a tunable laser in atomic its dimension are 50 × 50mm. The reflectivity of the spectroscopy and environmental analysis. LDS 698 dye partial reflector is 10% at 650nm. The solid dye cell is laser can be used for hydrogen plasma spectroscopy. located between the total reflector and the diffraction Solid dye laser has the advantages that are cheap, grating. The partial reflector is in the direction of 1st compact and simple to operate. Recently, compact solid order diffracted light from the grating. The length of the dye lasers have been developed by many researchers resonator is 80 nm. The solid dye cell is pumped by the with various solid-host materials by the sol-gel and 2nd harmonics of the Nd-YAG laser (532nm). When a polymerization methods. However, the durability is the narrower spectrum or a scanning of the spectrum is main problem in the solid dye laser because of the dye needed, it can be achieved by adding a turning mirror at bleaching. To fabricate the reliable diagnostic system of the position of the 0th order diffraction beam. -
3-5 Development of an Ultra-Narrow Line-Width Clock Laser
3-5 Development of an Ultra-Narrow Line-Width Clock Laser LI Ying, NAGANO Shigeo, MATSUBARA Kensuke, KOJIMA Reiko, KUMAGAI Motohiro, ITO Hiroyuki, KOYAMA Yasuhiro, and HOSOKAWA Mizuhiko An optical lattice clock and a single ion optical clock are being developed in National Institute of Information and Communications Technology (NICT). Diode lasers are used for the develop- ment of extremely narrow linewidth clock lasers for optical frequency standards. Using the Pound- Drever-Hall technique, the required reduction of linewidth was achieved by locking the laser to an ultrahigh-fi nesse ultralow-expansion glass (ULE) reference cavity, which is set in the high vacuum chamber with a constant temperature and isolated against environmental noise and vibration. As a result, the laser linewidth is decreased down to several Hz. The Allan deviation is less than 4×10−15 at an averaging time over 100 s. A vibration-insensitive optical cavity has been designed, aiming the linewidth below 1 Hz. In this chapter, we report the present status of development of the clock lasers at NICT. Keywords Laser frequency stabilization, Diode laser, Optical reference cavity, Optical clock, Optical frequency standard 1 Introduction an uncertainty of 10−17 or less is divided into two types. The fi rst is the “optical lattice The second, the current time and frequency clock” [4] [5], neutral atoms are trap in the opti- standard unit, is defi ned according to the hy- cal lattice “magic wave length” and the second perfi ne structure transition of cesium atoms by is the “single ion clock” [6], single ion is con- the General Conference of Weights and Mea- fi ned to the Lamb-Dick regime. -
Main Requirements of the Laser • Optical Resonator Cavity • Laser
Main Requirements of the Laser • Optical Resonator Cavity • Laser Gain Medium of 2, 3 or 4 level types in the Cavity • Sufficient means of Excitation (called pumping) eg. light, current, chemical reaction • Population Inversion in the Gain Medium due to pumping Laser Types • Two main types depending on time operation • Continuous Wave (CW) • Pulsed operation • Pulsed is easier, CW more useful Optical Resonator Cavity • In laser want to confine light: have it bounce back an forth • Then it will gain most energy from gain medium • Need several passes to obtain maximum energy from gain medium • Confine light between two mirrors (Resonator Cavity) Also called Fabry Perot Etalon • Have mirror (M1) at back end highly reflective • Front end (M2) not fully transparent • Place pumped medium between two mirrors: resonator • Curved mirror will focus beam approximately at radius • However is the resonator stable? • Stability given by g parameters: g1 back mirror, g2 front mirror: L gi = 1 − ri • For two mirrors resonator stable if 0 < g1g2 < 1 • unstable if g1g2 < 0 g1g2 > 1 • at the boundary (g1g2 = 0 or 1) marginally stable Stability of Different Resonators Polarization and Lasers • Lasers often need output windows on gain medium in cavity • Output windows often produce polarized light • Polarized means light's electric and magnetic vectors at a particular angle • Normal windows lose light to reflection • Least loss for windows if light hits glass at Brewster Angle • Perpendicular polarization reflected • Parallel polarization transmitted with -
CRDS) Work? CRDS: a Technology That Can Assess the Amount of Molecules in the Air by Measuring the Molecular Absorption of Laser Light in an Optical Cavity
What Makes Cavity Ringdown Spectroscopy (CRDS) Work? CRDS: A technology that can assess the amount of molecules in the air by measuring the molecular absorption of laser light in an optical cavity. Light (photons) and Molecules Molecules can absorb light and get “excited” at special frequencies. hν CH4 molecule These special frequencies are molecule specific. H H f = special frequencies 1 k k= spring constant C f = 2π m m = mass H H Each type of molecule absorb light only at its special frequencies. Light is absorbed at special frequencies specific to each molecule. hν 1 k f = Detector π absorption 2 m Ethylene, C2O2 Methane hν hν’ Ethylene Detector absorption wavelength Methane, CH4 At these special frequencies, the greater the distance the light travels through the sample the greater the total absorption. short hν’ Detector absorption Same number of molecules per unit volume wavelength hν’ Detector absorption Long wavelength CRDS’s optical cavity transforms 45,000 ft (8.5 miles) into 22,500 round trips in a ~1 ft long sample cell. High Reliability Laser Frequency Meter Pressure Gauge Outlet Gas Flow Temperature Gauge (to pump) Sample Gas Inlet Photo Detector Three Mirror Optical Cavity ~1 ft Resulting in parts-per-billion sensitivity Control of these four factors make CRDS ideally suited to perform scientific and industrial measurements all over the world. • Detecting low levels of trace gases • Measuring small changes in the concentration of gases • Ensuring measurement accuracy • Ensuring long-term reliability of the measurement Aircraft