CALREC PRODUCT CATALOGUE

Audio Mixing and Processing, Routers and Networked Audio Transport

calrec.com Putting Sound in the Picture The established policy of Calrec Audio Ltd. is to seek improvements to the design, specifications and manufacture of all products. It is not always possible to provide notice outside the company of the alterations that take place continually. No part of this manual may be reproduced or transmitted in any form or by any means, Despite considerable effort to produce up to electronic or mechanical, including photocopying date information, no literature published by and scanning, for any purpose, without the prior the company nor any other material that may written consent of Calrec Audio Ltd. be provided should be regarded as an infallible Calrec Audio Ltd guide to the specifications available nor does Nutclough Mill Whilst the Company ensures that all details in this it constitute an offer for sale of any particular Hebden Bridge document are correct at the time of publication, product. West Yorkshire we reserve the right to alter specifications and England UK equipment without notice. Any changes we make Apollo, Artemis, Summa, Brio 36, Hydra Audio HX7 8EZ will be reflected in subsequent issues of this Networking and Bluefin High Density Signal document. The latest version will be available Processing (HDSP) are trade marks of Calrec Tel: +44 (0)1422 842159 upon request. This publication is for International Audio Ltd. Dolby®E is a registered trade mark Fax: +44 (0)1422 845244 usage. of Dolby Laboratories, Inc. All other trade marks Email: [email protected] are acknowledged. Calrec Audio Ltd reserve the right to change calrec.com specifications without notice. E & O.E. © 2016 Calrec Audio Ltd. All Rights Reserved. CONTENTS

Introduction 5 Surface Panels – Summa 26 IC6162/IC6212 26 Console Comparison 6 12 Fader Panel 26 CA6161 27 Surface Options – Apollo 7 Control Cell Panel 27 MD6171 28 Surface Panels – Apollo 8 Meter Display 28 IC5701 8 IM6158/IM6215 29 Fader Panel 8 8 Fader Panel 29 IC5717 9 ML6157 30 Dual Fader Panel 9 Monitor Panel 30 IM5705 10 ML6157 31 Monitor/Spill Panel 10 Touch Display 31 IW5718 11 Joystick/Spill Panel 11 Surface Layout - Brio 36 32 LS5957, LS6053 12 Loudspeaker Panel 12 Rear Connections - Brio 36 33 CA5700 13 Wild/Assign Panel 13 Processing Core – Apollo, Artemis Shine & Beam 34 MD5702 14 ED5708 34 TFT Screen 14 8U Core Enclosure 34 RT5707 15 UN5713 35 Broadcast Facilities Panel 15 Control Processor Card 35 MU5993/MU5799/MU6088/MU6194 16 UD5709/UD5927/UD5928 36 3rd Party Meter Panel 16 DSP Card 36 LS5930 17 RY5710 37 Loudspeaker Panel 17 Router Card 37 ZN5714 38 Surface Options – Artemis 18 Processing Core – Artemis Light, Summa 39 Surface Panels – Artemis 19 ED6207 39 IC5791 19 4U Core Enclosure 39 Fader Panel 19 JN6209 39 MU5794 20 Reset and Sync Interface Card 39 TFT Screen 20 UN6210 40 MY5792 21 Control Processor Card 40 Monitor Panel 21 UD6180 41 MW5940 22 DSP Card 41 Monitor/Spill Panel 22 RY6181 42 RT6082, RT6083, RT6084, RT6085, RT6089, RT6191 23 Router Card 42 Reset/Meter Panel 23 ZN6177 43 PSU Card 43 Surface Options – Summa 24 12+8 25 Hydra2-Hub 44 24+8 25 RY6 211-2 4 4 36+8 25 H2 HUB 44 I/O Options – Fixed Format 46 I/O Options – Other 74 AD5782 46 AD6217-2 74 Analogue mic/line 12 in/4 out – XLR 46 Fieldbox 8 In (XLR)/ 8 out Analogue (D-Type) “Tascam” standard 74 AD5781 47 Analogue Mic/Line 24 In/8 Out – XLR 47 DiGiCo Orange Box - Hydra 2 Interface 76 AD5780 48 Analogue Mic/Line 48 In/16 Out – XLR 48 EG6266-2 AoIP interface 77 AE5743, AE5991, AE5992 49 Analogue Mic/Line 32 In/32 Out – EDAC 49 AD6300 External I/O Rack for Brio 36 78 JB5606 50 Digital AES3 16 In/16 Out – BNC 50 Bluefin2 Customers 79 JB5783 51 Digital AES3 32 In/32 Out – BNC 51 JB5962 52 Digital AES3 Rear Mount 32 In/32 Out - BNC 52 JM5736, JM5831, JM5890 53 Dual MADI 53

I/O Options – Modular 54 AD5838 56 8 x Analogue Line Level inputs (D-Type) 56 AD6057 57 8 x Analogue Mic / Line Level inputs (D-Type) 57 AD5840 58 4 x Mic/Line In (XLR) 58 AL5870 59 2 x Mic/Line In with Splits (XLR) 59 BI6218 60 Waves SoundGrid (RJ45) 60 BI6192 61 with network redundancy (RJ45) 61 DA5839 62 8 x Analogue Line Out (D-Type) 62 DA5867 63 4 x Line Out (XLR) 63 JB5860 64 4 x Digital AES Input (BNC) 64 JX5869 65 4 x Digital AES Input (XLR) 65 JD5842 66 8 In, 8 Out Digital AES (D-Type) 66 JB5837 67 4 x Digital AES Output (BNC) 67 JX5868 68 4 x Digital AES Output (XLR) 68 JM6199 69 1 X MADI IN/OUT-AES10 (BNC / SFP) 69 VI5872 70 2 x SDI Embedder (BNC) 70 VO5841 71 2 x SDI De-Embedder (BNC) 71 WY5858 72 GPIO, 8 In / 8 Full Changeover Out (D-Type) 72 WY5859 73 GPIO, 8 In / 16 Out (D-Type) 73 INTRODUCTION

Calrec Audio supplies audio broadcast mixing consoles which are relied on by the world’s most successful broadcasters. Formed as a microphone manufacturer in 1964, Calrec celebrated 50 years as audio specialists in 2014. The company’s reputation for build quality, reliability and audio performance has made it an industry benchmark across the world.

Today, broadcasters demand even more versatility and integration from their audio equipment, and in this technologically-progressive era TV companies want to ensure that their systems can produce programmes efficiently and to required specifications. For their audio systems to achieve this, greater consideration has to be given to their networks as a whole, and how efficiently they can be controlled. Calrec has designed its range of consoles to meet these demands.

Consistently pushing technology barriers, the Apollo platform introduced Bluefin2, the next generation of award-winning Bluefin technology. It provides over 1000 channel processing paths on just one DSP card. For surround sound mixing it is the industry’s most advanced and economical solution. In the Apollo, Artemis and Summa consoles, and the Hydra2 network, Calrec provides intelligent solutions for easily sharing network I/O resources and control data.

This Product Guide provides detailed descriptions for every single item of Calrec hardware, from the biggest Apollo console to the smallest Summa. It covers panel options, Calrec’s full range of fixed format and modular Hydra2 units, and dimensions for a variety of console configurations. It also provides a quick and easy console comparison to select the right console to meet your requirements.

Note: This product Guide now includes our latest console Brio 36 and its associated hardware including its new BRIO expansion rack.

For putting sound in the picture, broadcasters trust in Calrec.

CALREC Putting Sound in the Picture 5 CONSOLE COMPARISON

Apollo Artemis Shine Artemis Beam Artemis Light Summa Brio 36

Physical Up to 160 (single 12+8, 24+8 or Up to 72 Up to 64 Up to 56 36 Faders or dual) 36+8

Input 1020 680 340 240 180 or 128 64 Channels Up to 16 from Up to 16 from Up to 16 from Up to 16 from Up to 4 from Main Output 4 x 5.1/stereo/ Main/Group pool Main/Group pool Main/Group pool Main/Group pool Main/Group pool Buses mono of 128 mono legs of 128 mono legs of 128 mono legs of 72 mono legs of 36 mono legs Up to 48 from Up to 48 from Up to 48 from Up to 48 from Up to 8 from Audio Group 8 x 5.1/stereo/ Main/Group pool Main/Group pool Main/Group pool Main/Group pool Main/Group pool Buses mono of 128 mono legs of 128 mono legs of 128 mono legs of 72 mono legs of 36 mono legs Track/ Up to 96 from a Up to 64 from a Up to 64 from a Up to 48 from a 32 x stereo/ IFB Output pool of 96 mono pool of 64 mono pool of 64 mono pool of 48 mono N/A mono Buses legs legs legs legs Track/IFB Sends per 4 4 4 4 1 N/A Path Up to 48 from Up to 32 from Up to 32 from Up to 24 from Up to 24 from Aux Output 16 x stereo/ pool of 48 mono pool of 32 mono pool of 32 mono pool of 24 mono pool of 24 mono Buses mono legs legs legs legs legs Direct/ Up to 1 x direct Up to 1 x direct Mix-Minus Up to 4 outputs Up to 4 outputs Up to 4 outputs Up to 4 outputs output and/or output and/or Outputs per from pool of 512 from pool of 512 from pool of 512 from pool of 256 1 x mix-minus 1 x mix-minus Channel/ mono legs mono legs mono legs mono legs output from pool output from pool Group of 188 mono legs of 64 mono legs 1 appropriate Insert Send Pool of 256 Pool of 256 Pool of 256 Pool of 128 Pool of 64 width insert per & Returns mono legs mono legs mono legs mono legs mono legs path EQ on 6 full bands of 6 full bands of 6 full bands of 6 full bands of 6 full bands of 6 full bands of Channels, parametric EQ/ parametric EQ/ parametric EQ/ parametric EQ/ parametric EQ/ parametric EQ/ Groups and filters filters filters filters filters filters Mains 2 x compressor/ 2 x compressor/ 2 x compressor/ 2 x compressor/ 2 x compressor/ limiters limiters limiters limiters limiters 2 x compressor/ +1 x expander/ +1 x expander/ +1 x expander/ +1 x expander/ +1 x expander/ limiters Dynamics gate/ducker per gate per gate per gate per gate per +1 x expander/ Channel, Group Channel, Group Channel, Group Channel, Group Channel, Group gate per path Aux (no C/L2) & & Main & Main & Main & Main Main (no E/G/D) Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 5.4s per input from pool input from pool Input Delay input from pool input from pool input from pool of input from pool of 256 mono of 256 mono of 128 mono legs of 128 mono legs 128 mono legs of 64 mono legs legs legs Up to 5.4s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Path Delay input from pool path path path path path of 64 mono legs Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 2.73s per Up to 5.4s per Output output from pool output from pool output from pool output from pool output from pool input from pool Delay of 256 mono of 256 mono of 128 mono legs of 128 mono legs of 128 mono legs of 64 mono legs legs legs Hydra2 16 / 32 16 / 32 16 / 32 8 8 1 (optional) Connections

6 CALREC Product Catalogue SURFACE OPTIONS – APOLLO

Apollo surface sizes are very flexible. A number of chassis sections are fitted together to provide space for the required panel layout. Chassis sections come in a variety of widths, defined by how many control panels they can hold. Currently available sections are: 2, 2.5, 3 and 3+. Some standard surface options are shown in the table below.

As shown, 80 is the maximum number of faders allowable on the Apollo stand but each Apollo system can have up to 160 faders. This can be achieved by having multiple surface sections on stands connected to the same core.

Two side trim options are available: Studio - 50mm or Slim - 10mm. Two stand height options are available: 740mm and 700mm.

Max Surface Width, including Fader Section Max Surface Width, including 10mm trim at each end Internal Leg* External Leg* Count Make-up 50mm trim at each end (no monitor mount) 32 2/2.5 1242mm [48.90"] 1162mm [45.75"] 1042mm [41.02"] 1212mm [47.72"]

48 2/2.5/2 1748mm [68.82"] 1668mm [65.67"] 1548mm [60.04"] 1718mm [67.64"]

56 3/2.5/2 1998mm [78.66"] 1918mm [75.51"] 1798mm [70.79"] 1968mm [77.48"]

64 3/2.5/3 2248mm [88.50"] 2168mm [85.35"] 2048mm [80.63"] 2218mm [87.32"]

72 3/3+/3 2378mm [93.62"] 2298mm [90.47"] 2178mm [85.75"] 2348mm [92.44"]

72 2/3/2.5/2 2504mm [95.58"] 2424mm [95.43"] 2304mm [90.71"] 2474mm [97.40"]

80 3/2/2.5/3 2754mm [108.43"] 2674mm [105.28"] 2554mm [100.55"] 2724mm [107.24"]

*Internal / external leg widths do not include the floor fixing plates fitted on OB version. Accessory Stock Code SFP Option Stock Code

Sliding script tray SS5807 SX LC 491-087

Loudspeaker stands LS5805 Copper 4 91-114

Backup laptop 491-184 LX-LC 491-072 491-196 Backup PC PR5980 Bi-Di (10k) 491-195 Wall-mount screen arm 491-190

CALREC Putting Sound in the Picture 7 SURFACE PANELS – APOLLO

IC5701 250 mm

FADER PANEL

The IC5701 is fitted with 8 x 100mm throw faders. Multiple fader panels make up the required fader quantity on the surface. As standard, the panel is fitted with ‘Cut’ buttons to mute fader paths. As an option, ‘On’ buttons can be fitted and the software configured for reverse functionality. If ‘On’ buttons are required, this should be specified at the time of order.

8 CALREC Product Catalogue IC5717 250 mm

DUAL FADER PANEL

The IC5717 is a dual fader panel, fitted with 8 x 100mm throw faders and a second row above of 8 x 60mm faders. The panel is the same physical size as the IC5701 with some strip functionality removed to make space for the second row of faders. The dual fader panel gives physical access to both A and B layers simultaneously.

CALREC Putting Sound in the Picture 9 IM5705 130 mm

MONITOR/SPILL PANEL

The monitor/spill panel fits in either row of the control bed, providing a dedicated set of main monitoring controls. As well as monitoring controls, this panel provides surround spill and downmix faders for in-depth control over surround paths. The faders on this panel can also be used to control Main output bus levels if required. Eight momentary buttons with LED tallies are fitted at the bottom of the panel that can be assigned to GPIO for the triggering of external devices, for example, for talkback or remote start of playout devices. If required, for example on a large console, or for multiple operators, multiple monitor/spill panels can be fitted in the same control surface. Each can switch between controlling monitor 1 or monitor 2 outputs as well as having access to miscellaneous monitor and headphone outputs.

10 CALREC Product Catalogue IW5718 130 mm

JOYSTICK/SPILL PANEL

The joystick/spill panel, like the monitor/ spill panel, is ‘half-width’ and can fit in either row of the control bed. Typically it would be located above the monitor/ spill panel. This panel provides joystick control over surround panning / output positioning from mono and stereo paths. Like the monitor/spill panel, the joystick/ spill panel also provides assignable control over surround path spill and downmix settings, as well as allowing its faders to be assigned to Main output buses if required.

CALREC Putting Sound in the Picture 11 LS5957, LS6053 130 mm 130 mm

LOUDSPEAKER PANEL

The LS5957/LS6053 loudspeaker panels provide a mono loudspeaker with four separate balanced stereo audio inputs. The panels can be fitted into either of Apollo’s control bed rows.

Audio input connections are made to the rear of the panel via a 25 pin D-Type connector.

DIP switches are provided on the rear of the panel for individually enabling/ CUT CUT CUT CUT CUT CUT CUT CUT disabling left and right portions of each input feed and Cut/On switches are provided above each level control.

DIP switches are also provided to set the frequency response of the incoming audio, three options are available: Flat, high frequency filter (4k7 Hz), low frequency filter (215 Hz).

Level rotary controls are illuminated to ease identification and the illumination colour of each can be set using rotary controls on the rear of the panel.

LS6053 provides an additional rotary level control for controlling an audio feed to an external loudspeaker. The external audio feed is connected through the panel using EXT LS a 9 pin D-Type connector on the rear of the panel.

12 CALREC Product Catalogue CA5700 250mm

WILD/ASSIGN PANEL

Assignable control panels can quickly switch between 4 main operating modes, giving access to the majority of operational functions, and can also be used in “wilds” mode to provide in-line control functions for the fader directly below each strip. A wild/assign panel needs to be located above a fader panel in order for it to be fully functional and for mode selection to be performed. Multiple wild/assign panels can be fitted in order to provide multiple modes of control parameters at the same time, for multiple operators working on the same console at the same time as well as giving control to all functions from various physical locations across the console.

CALREC Putting Sound in the Picture 13 MD5702 250mm

TFT SCREEN

A number of TFT screens can be fitted in the control surface upstand to display input and output audio metering, dynamics gain reduction metering and loudness metering. Each upstand screen requires a fader panel to carry out its processing and therefore the maximum number of upstand screens fitted in a console is the same as the number of fader panels fitted. TFT screens are the same width as fader and wild/assign panels.

14 CALREC Product Catalogue RT5707

BROADCAST FACILITIES PANEL

Each control surface requires that a Broadcast Facilities panel is fitted in the upstand. This panel is 55mm [2.17”] wide and as such is ideally fitted alongside a 3rd party meter panel (see next page) to take up the same width as a standard panel (250 mm).

The Broadcast Facilities panel provides the following:

• Resets • Talkback Mic • USB Port • Facilities Buttons/Indicators

CALREC Putting Sound in the Picture 15 MU5993/MU5799/MU6088/ MU6194

3RD PARTY METER PANEL

The MU5993, MU5799 or MU6194 can be fitted with a RTW TM7, DK AudioMSD600++ or RTW TM9 meter respectively. The MU6088 can be fitted with two DK2 meters. Choice should be specified at time of order although they can be retrofitted.

MU5993, MU5799 and MU6088 – 195 mm

MU6194 – 250 mm

16 CALREC Product Catalogue LS5930 130 mm

LOUDSPEAKER PANEL

The LS5930 loudspeaker panel provides a mono loudspeaker with four separate balanced stereo audio inputs. The panel can be fitted into Apollo’s upstand.

Audio input connections are made to the rear of the panel via a 25 pin D-Type connector.

DIP switches are provided on the rear of the panel for individually enabling/ disabling left and right portions of each CUT CUT CUT CUT input feed and Cut/On switches are provided above each level control.

DIP switches are also provided to set the frequency response of the incoming audio, three options are available: Flat, high frequency filter (4.7 kHz), low frequency filter (215 Hz).

Level rotary controls are illuminated to ease identification and the illumination colour of each can be set using rotary controls on the rear of the panel.

CALREC Putting Sound in the Picture 17 SURFACE OPTIONS – ARTEMIS

Artemis surface sizes are very flexible. A number of chassis sections are fitted together to provide space for the required panel layout. Chassis sections come in a variety of width, defined by how many control panels they can hold. Currently available sections are: 2, 2.5 and 3.5. Some standard surface options are shown in the table below.

Two side trim options are available for Artemis: Standard (18 mm) and Thin (5 mm). Two types of stand are available: Studio (733 mm) and Bolt-Down ‘OB’ (740.8 mm) both are available as reduced height versions which brings the height down by 40 mm.

Total width Total width Total width Total width Fader Section Standard trim Standard trim Standard trim Thin trim (5mm) External Internal leg Count Make-Up 1 x monitor 2 x monitor No monitor No monitor leg mount mount Mount mount 807mm 852mm 762mm 736mm 450mm 610mm 16 2.5 [31.77”] [33.54”] [30.00”] [28.98”] [17.72”] [24.02”] 1067mm 11.12m m 1022mm 996mm 580mm 740mm 24 3.5 [42.01"] [43.78"] [40.24"] [39.21"] [22.83"] [29.13"] 1333mm 1378mm 1288mm 1262mm 840mm 1000mm 32 2/2.5 [52.48"] [54.25"] [50.71"] [49.69"] [33.07"] [39.37"] 1593mm 1638mm 1548mm 1522mm 1106mm 1266mm 40 2/3.5 [62.72"] [64.49"] [60.94"] [59.92"] [43.54"] [49.84"] 1859mm 1904mm 1814mm 1788mm 114 0 m m 1300mm 48 2/2.5/2 [73.19"] [74.96"] [71.42"] [70.39"] [44.88"] [51.18"] 2119 m m 2164mm 2074mm 2048mm 1330mm 1490mm 56 2/3.5/2 [83.43"] [85.20"] [81.65"] [80.63"] [58.66"] [58.66"] 2385mm 2430mm 2340mm 2314mm 1330mm 1490mm 64 2/2/2.5/2 [93.90"] [95.67"] [92.12"] [91.10"] [58.66"] [58.66"] 2645mm 2690mm 2600mm 2574mm 1596mm 1756mm 72 2/3.5/2/2 [104.13"] [105.91"] [102.36"] [101.34"] [62.83"] [69.13"]

Accessory Stock Code SFP Option Stock Code

Sliding script tray SS5865 SX LC 491-087

Loudspeaker stands LS5844 Copper 4 91-114

Backup laptop 491-184 LX-LC 491-072 491-196 Bi-Di (10k) 491-195

18 CALREC Product Catalogue SURFACE PANELS – ARTEMIS

IC5791 260 mm

FADER PANEL

The IC5791 is fitted with 8 x 100mm throw faders. The upper half of the panel works in conjunction with an upstand TFT display that should be fitted directly above the fader panel in order to gain full access to assignable panel controls such as EQ, routing, output control etc. As standard, the panel is fitted with “Cut” buttons to mute fader paths. As an option, “On” buttons can be fitted and the software configured for reverse functionality – the fader path is active when On is lit and muted when it is not.

CALREC Putting Sound in the Picture 19 MU5794 260 mm

TFT SCREEN

TFT touchscreen panels make up the majority of the Artemis upstand. The upper section of upstand TFT panels display audio level and phase meters, as setup in the Main PC Application. The lower section of the panel works in conjunction with the fader panel fitted directly below, providing assignable panel display and control for EQ, routing, output control etc. This panel will not be functional without a fader panel to drive it.

20 CALREC Product Catalogue MY5792 200 mm

MONITOR PANEL

The monitor panel fits in the control bed, providing a dedicated set of main monitoring controls. As well as monitoring controls, this panel also provides On-Air / Rehearse condition switching, GPIO assignable momentary buttons and LED tallies, as well as talkback keys. If required, for example on a large console or for multiple operators, multiple monitor panels can be fitted. Each can switch between controlling monitor 1 or monitor 2 as well as having access to miscellaneous monitor / headphone outputs.

CALREC Putting Sound in the Picture 21 MW5940 200 mm

MONITOR/SPILL PANEL

The MW5940 version of monitor panel has all the functionality of the MY5792 with the addition of surround spill / downmix faders for in-depth control over surround paths and a joystick for surround panning / output positioning of mono or stereo paths. Monitor panels fit in the control bed, providing a dedicated set of the main monitoring controls. As well as monitoring controls, surround spill, surround downmix and joystick panning, this panel also provides On-Air / Rehearse condition switching, GPIO assignable momentary buttons and LED tallies, as well as talkback keys.

22 CALREC Product Catalogue RT6082, RT6083, RT6084, RT6085, RT6089, RT6191

RESET/METER PANEL

An upstand mounted reset/meter panel is normally fitted above the dedicated monitor panel. Several variants of this panel are available with different metering options. Reset/meter panels can be supplied with a variety of 3rd party meters from specialist meter manufacturers such as RTW and DK, offering visual surround field representation with comprehensive phase metering, alongside other features such as loudness metering, stereo vectorscopes and moving-coil emulations. Reset/meter panels are also available with no 3rd party meters fitted.

Meter options are currently as follows:

RT6082 – Single RTW TM7

RT6083 – Twin RTW TM7

RT6084 – Single DK MSD600++

RT6085 – Twin DK MSD600++

RT6089 – No Meters Fitted

RT6191 – Single DK T7

Moving coil meters are no longer available but if you can supply some the following panels can be chosen to fit them. These panels can be provided with various mounting kits to fit DK or RTW meters in the bottom section of the panel:

RT5843 – PPM

RT5864 – VU

CALREC Putting Sound in the Picture 23 SURFACE OPTIONS – SUMMA

The Summa surface comes in three fixed formats, 12+8, 24+8 and 36+8. Each surface has one 8 fader section and at least one 12 fader section. Larger surfaces have multiple 12 fader sections. 8 fader sections are made up of an 8 fader panel, a monitor panel and a touch display. 12 Fader sections are made up of a 12 fader section, a control cell panel and a meter display. The following pages describe each panel in detail. Summa 24+8 is shown below and top down images of each surface are shown on the next page.

Fader Count Section Make-up Total width

One 8 fader section and 875.5 mm 12+8 one 12 fader section [34.47”]

One 8 fader section and 1308 mm 24+8 two 12 fader sections [51.5”]

One 8 fader section and 1740.5 mm 36+8 three 12 fader section [68.5”]

24 CALREC Product Catalogue 12+8

24+8

36+8

CALREC Putting Sound in the Picture 25 SURFACE PANELS – SUMMA

IC6162/IC6212 432 mm

12 FADER PANEL

The 12 fader panel is made up of 12 100mm motorised faders* with PFL overpress. Each fader has its own PFL and AFL, Cut (or On if needed), Access, Link and Talkback buttons and a small TFT display.

* Alps faders supplied as standard, Penny and Giles faders available on request

26 CALREC Product Catalogue CA6161 432 mm

CONTROL CELL PANEL

The control cell panel is made up of 24 control cells, each of which include a small TFT display and rotary control and a push button. Two control cells are situated directly above each fader. When the surface is in one of the ‘strip’ modes the control cells operate on the paths attached to the faders directly below. With the surface in access mode all control cells operate on the accessed path.

Above each pair of control cells is an input gain rotary control.

CALREC Putting Sound in the Picture 27 MD6171 432 mm

METER DISPLAY

The meter display is a large high resolution TFT display which displays fader meters along the bottom and bus/ output meters across the top.

28 CALREC Product Catalogue IM6158/IM6215 432 mm

8 FADER PANEL

The 8 fader panel is made up of 8 100mm motorised faders* with PFL overpress. Each fader has its own PFL and AFL, Cut (or On if needed), Access, Link and Talkback buttons and a small TFT display.

To the left of the faders is the Link Clear button which quickly unlinks all faders on the surface. Under this are the six layer selection buttons.

To the right of the faders are the 12 User Buttons which can be used to activate and provide feedback for GPIO connections.

* Alps faders supplied as standard, Penny and Giles faders available on request

CALREC Putting Sound in the Picture 29 ML6157 432 mm

MONITOR PANEL

On the left are the various control mode buttons with access mode at the top and all the function-specific strip modes underneath. Control modes determine which parameters are available in the surface control cells.

Next there are the console monitor controls and the studio monitor controls: level, dim, cut, downmix etc.

To the right of these is the parameter adjust control which is a single rotary and push button which can be used to control any touch screen parameter, simply by selecting it.

On the right is the recessed surface reset button, status LED and three USB ports which can be used to attach a keyboard, mouse, or USB storage device to backup or restore Summa settings.

30 CALREC Product Catalogue ML6157 432 mm

TOUCH DISPLAY

The touch display is a large, high resolution TFT touch screen which is used for accessing the main Summa interface.

CALREC Putting Sound in the Picture 31 SURFACE LAYOUT - BRIO 36

The BRIO 36 surface is built as 2 panels top and bottom and is only supplied as a complete console except for the optional Hydra2 interface module and the 3 double-width modular I/O slots in the rear which can be populated with any of the I/O cards from the modular I/O range.

The surface is made up from 3 x 12 fader sections, 2 across the bottom and one top left and one Access Panel placed top right which contains the Access display area complete with touchscreen TFT, 8 context based rotary controls, 12 Global user switches G1 to G12, A/B layer selection, Link Switch, Monitor Controls, PFL level, Reset switch and USB port used for data transfers. In addition there is a USB port for a keyboard/mouse combination and a Stereo 1/4” Headphone socket built into the front of the surface.

BRIO 36 SURFACE AREAS

12 Fader Section Touchscreen Panel

Fader Displays Rotary Controls Access Buttons & User Buttons

Fader Controls Access, User and AFL, PFL & Cut Monitor Controls, Reset & USB Port

12 Fader Section 12 Fader Section

Fader Count Surface Make-up Total width

Three 12 fader sections arranged as A/B Layers 892.0 mm 36 Plus Touchscreen Panel [35.12”] in the Access, User and Monitor controls section

32 CALREC Product Catalogue REAR CONNECTIONS - BRIO 36

The BRIO 36 surface is designed to The left hand SFP, when viewed from To the right of the expansion slots are be a self-contained compact mixing the rear of the surface, is the primary placed 4 x 9-pin D-Sub connectors each console however there are a number connection and the SFP on the right is the of which carry 4 x GPI or 4 x GPO circuits of external connections that are secondary connection. providing a total of 8 In & 8 Out GPIOs. made to interface to other equipment such as I/O, Networks and OEM Next to these are the GUI and Meter These general purpose are classed as equipment. Some of these require DVI out connectors. The GUI connector being in slot F, for patching purposes. fibre connections via singlemode or provides a backup to the touchscreen multimode usually via LC SFPs. interface which together with a USB 2 columns of 8 x Digital ports on BNCs (1 keyboard allows the system to continue column of 8 AES3 Outputs & 1 column of Looking from left to right across the rear in the event of touchscreen failure. 8 AES3 Inputs with SRC column) appear panel, there are:- Note: there is a USB port in the front of next to the GPIO providing 8 x Digital the console for this purpose. Stereo AES3 outputs and inputs. 2 x IEC power sockets labelled PSU 1 and PSU 2, either of which can power The Meter DVI provides up to 4 rows These digital outputs and inputs are the console, together they provide power of user definable metering, including classed as being in slot B for patching redundancy. The IEC inputs should be compliant loudness meters, and dynamics purposes. fed from separate AC sources to protect gain reduction meters on a customer against external power loss. In the event provided TFT screen. There are 16 analogue line outputs on that only one AC outlet is available, power XLR male connectors next to the AES should be fed via the supplied IEC Y-Split 2 x connectors labelled 1 & 2 connectors arranged in a 4 x 4 block cable to provide redundancy against are placed to the right of the DVI Outputs numbered 1-4, 5-8, 9-12 & 13-16. internal PSU failure. and are used to connect to 3rd party equipment for Ember+ , SWP-08 control Finally there are 24 analogue Mic/Line Below the power cable strain relief or other OEM interfaces. Alternatively inputs with Phantom Power on XLR clips and large whisper quiet fan are 6 they can connect to Calrec H20 or Calrec female connectors arranged in a 6 x 4 x BNC connectors that provide options Assist interfaces. block numbered 1-6, 7-12, 13-18 & 19-24. for external Sync connections, the 2 x Wordclock, 2 AES & 2 Video BNC ports. There are 3 double expansion slots These analogue outputs and inputs are labelled C, D & E are available next to classed as being in slot A for patching 2 x Hydra 2 SFP interface connections these and any of the Calrec Modular I/O purposes. are located next to the Sync connectors cards may be fitted and the empty spaces which, when the optional Hydra 2 module filled with single blanking plates, see is fitted allows connections to external I/O ”I/O Options – Modular” on page 54 on the Calrec network. onwards to see the modular I/O range.

BRIO 36 REAR CONNECTIONS

CALREC Putting Sound in the Picture 33 PROCESSING CORE – APOLLO, ARTEMIS SHINE & BEAM

ED5708 Accessory Stock Code Perle Iolan SCS8 (serial to TCP/IP 491-189 8U CORE ENCLOSURE remote control data conversion)

The Apollo, Artemis (Shine and Beam) Serial to RJ45 312-269 and Router Core processing core is an Blanking plate 650-167 8U 19” rack mount enclosure designed for installation in standard 19” equipment KVM (when in use as Router Core) 4 91-211 bays. The core is cooled by fan assisted convection. Air is drawn in from the front 1U PC (when in use as Router Core) 491-212 into the cable-tray and up through the base of the card frame. Fans mounted in the top of the core pull air through the card frame which then exits through vents across the top of the rear of the core. A fully populated core has been measured to produce <40dB acoustic noise. All connections, including power, are made to the front of the core which is recessed from the racking angles to allow cable clearance within the bay.

34 CALREC Product Catalogue UN5713

CONTROL PROCESSOR CARD

Slots 4 and 5 are for control processor modules, slot 4 for the primary / normally active card, slot 5 for the secondary / hot-spare. The active Master Controller is the central processor in the system, handling all control parameters and directing data between control surface, DSP and router. At the top of the module are two SFP slots that can be fitted with copper or fibre SFPs for interfacing with the control surface. As well as the standard status indicators, front panel LEDs are also provided to show the status of other cards in the core.

If Dual Router Core redundancy is chosen as an option, to split redundancy across two physical locations, redundant core link cards (UN6149) are required in both primary and secondary cores to provide a backup data link between the two cores.

UN6149 REDUNDANT CORE LINK CARD

CALREC Putting Sound in the Picture 35 UD5709/UD5927/UD5928

DSP CARD

The primary, normally active DSP card fits in slot 3, the secondary, hot-spare in slot 6. DSP cards are not required in Router Cores. This audio processing module has no front panel connectors. All audio and data is passed to / from the Master Controller and router cards via the core backplane.

UD5709 – Apollo

UD5927 – Artemis Shine

UD5928 – Artemis Beam

36 CALREC Product Catalogue RY5710

ROUTER CARD

The primary router card fits in slot 2, the secondary in slot 7. As an option, slots 1 and 8 can be fitted with additional router expander modules of the same type to double the number of Hydra2 connections in the core. The Apollo and Artemis (Shine and Beam) router card has 16 SFP ports that can be fitted with copper or fibre SFPs to allow connection of Hydra2 I/O boxes and connections to other consoles’ and Router Cores’ routers. A single RJ45 port labeled ‘Ethernet’ allows for the connection of 3rd party equipment supporting the SW-P-08 o r E m b e r p r o t o c o l s f o r r e m o t e c o n t r o l . As well as standard status LEDs there are front panel LED indicators to show activity on each port.

CALREC Putting Sound in the Picture 37 ZN5714

PSU Card Card slots 9 and 10 are for PSU modules. Both slots share the power load for the whole core. One PSU module is sufficient to power the whole core, two are fitted to provide redundancy. Each card has an IEC AC mains input connector, requiring 100–240V AC.

38 CALREC Product Catalogue PROCESSING CORE – ARTEMIS LIGHT, SUMMA

ED6207 JN6209

4U CORE ENCLOSURE RESET AND SYNC INTERFACE CARD

The Artemis Light and Summa processing This module fits in the central, 5th card core is a 4U 19” rack mount unit slot of the Artemis Light / Summa designed for installation into standard processing core. Three buttons can 19” equipment bays. The core is cooled individually reset the control, router and by fan assisted convection. Air is drawn DSP cards within the core. The bottom in through inlets on the front panels of button, ‘enable’, must be pressed at the the cards fitted in the core. Air exits via same time as any of the resets as a safety 9 fans mounted to the rear of the core, precaution. Front panel LED indication across the top. The speed of each fan is shows the status of the fans within the monitored and error reports are generated core. 4 x BNC connectors provide sync for any failures. Air inlets and fans should inputs, allowing for redundancy and a be left clear and unobstructed to ensure range of formats. Two inputs are for SD / air can flow through the card frame. No HD video sync signals, one for AES DARS clearance is required above or below and one for TTL Wordclock. the core for cooling. All connections, including power. are made to the front of the core which is recessed from the Accessory Stock Code racking angles to allow cable clearance Perle Iolan SCS8 (serial to TCP/IP within the bay 491-189 remote control data conversion) Serial to RJ45 312-269

CALREC Putting Sound in the Picture 39 UN6210

CONTROL PROCESSOR CARD

Card slots 4 and 6, immediately adjacent on either side of the reset and sync card, are for Control Processor cards. Slot 4 is for the primary, normally active card and slot 6 is for the secondary, hot-spare card. As well as the standard status LEDs, LEDs are provided to show activity on the RJ45 and SFP ports. LEDs are also provided to show the heartbeat status of other cards within the core.

Three ethernet ports are provided for interfacing with external control systems. Two surface connections are available for connecting a the control surface, an extension or sidecar if required (Artemis only) and a maintenance PC.

Redundancy is optional when a Summa with 128 channels is chosen. Secondary cards are replaced with blanking plates in non-redundant systems.

40 CALREC Product Catalogue UD6180

DSP CARD

The primary, normally active DSP card fits in slot 3, to the immediate left of the primary Control Processor. The secondary, hot-spare DSP card fits in slot 7, to the immediate right of the secondary Control Processor. This audio signal processing card has no front panel connections. All audio and data is passed to / from the Control Processor and Router cards via the core backplane.

Redundancy is optional when a Summa with 128 channels is chosen. Secondary cards are replaced with blanking plates in non-redundant systems.

CALREC Putting Sound in the Picture 41 RY6181

ROUTER CARD

Card slot 2 is for the primary router module, slot 8 is for the secondary router module. The Artemis Light / Summa router card has 8 SFP ports that can be fitted with copper or fibre SFPs to allow connection of Hydra2 I/O boxes and connections to other consoles or Router Cores. A single RJ45 port labeled Ethernet allows for 3rd party equipment supporting the SW-P-08 or Ember protocols to interface for remote control. As well as the standard status LEDs there are front panel indicators to show the active sync source and for activity on the RJ45 and SFP ports.

Redundancy is optional when a Summa with 128 channels is chosen. Secondary cards are replaced with blanking plates in non-redundant systems.

42 CALREC Product Catalogue ZN6177

PSU CARD

Card slots 1 and 8 are for PSU modules. Both slots share the power load for the whole core. One card is sufficient to power a fully populated core, two are fitted to provide redundancy. Each card has an IEC AC mains input connector, requiring 100–240 V AC. LEDs provide front panel indication for incoming mains voltage (POK), 5 V and 12 V DC output voltages and an over temperature warning. Failures are also reported by the console’s system status monitoring system.

Redundancy is optional when a Summa with 128 channels is chosen. Secondary cards are replaced with blanking plates in non-redundant systems.

CALREC Putting Sound in the Picture 43 HYDRA2-HUB

RY6211-2 H2 HUB

FIGURE 1. H2HUB - FRONT VIEW

The H2Hub provides a network A 10-30V DC input allows an optional Primary and Secondary SFP slots are also distribution node that can be used to external PSU to be connected to provide provided for up to 4 downstream ports connect from a router up to 4 external redundancy if required. which can either be connected to Calrec connections which may be I/O boxes I/O Units or other H2Hubs. or other Hubs to form a local array of Battery powered operation I/O connectivity, in a compact, cost- The DC input is also suitable for use with The H2Hub must be given an ID which effective package. batteries. Batteries can be used as a is unique on the network, before being backup to the internal AC supply, or as connected. The ID is a value from 1 to Enclosure the primary power source. There is no 64, set as a binary representation using The H2Hub is 220mm wide x 284mm drain on the battery whilst the unit is fed DIP switches accessible from the rear. deep x 40mm (<1U) high. Threaded fixing with AC, yet switch-over from AC to DC is Note that Hub ID’s are different to I/O holes in the base allow the unit to be seamless. Box HID’s so no conflict occurs if an I/O secured in place if required. Box and a Hub have the same ID. A wide range of suitable batteries are Cooling commonly available from broadcast Two other switches are also provided The unit has a single ultra low noise suppliers. Costs vary significantly based on the rear of the unit the first is the fan. Air is drawn in from the front and on run time and other factors. Calrec Split / Contained switch. The unit is extracted from the rear, please allow at recommends the use of Anton Bauer normally used in Contained mode where least 25mm (1’) clearance at the front G150 batteries in conjunction with their both Primary and Secondary connections a n d r e a r o f t h e u n i t f o r o p e r a t i o n u p t o QR-UNIV XLR mount to provide a runtime are made to the same hub. In this mode 40 deg C (104 deg F) ambient in excess of 12 hours. ‘Hot-swap’ battery the Upper row of SFP’s are used for temperature. mounts are also available to fit 2 batteries Primary connections and the lower row that can be individually swapped out used for Secondary connections. Power without interrupting operation. The H2Hub contains a single AC mains In certain situations extra redundancy PSU that can be fed 100-240V AC via The DC input is protected by ISO 7637-2 may be provided by switching this to ‘Split’ a rear mounted IEC connector. The IEC circuitry against surges, reverse polarity the Hub. In this mode each Hub only connector has a retaining clip that can and other external power faults. manages either the Primary or Secondary hold some types of IEC cables in place. connection which is determined by the The cable supplied with the unit has a built Hydra2 network connections Pri /Sec switch adjacent. Another hub in latching mechanism and does not need A pair of front mounted SFP slots provide is then required to be in ‘Split’ mode to be clipped in place. primary and secondary connections back with the same ID to manage the other to routers in a Hydra2 network. Various paired connection for mission critical I/O fibre and copper SFP modules can be redundancy. Note that in ‘Spilt’ Mode , supplied.

44 CALREC Product Catalogue FIGURE 2. H2 HUB - REAR VIEW

only the Upper row of SFP’s are used for both Primary and Secondary connections.

The Front Panel LEDs indicate the mode of operation and which SFP’s are active.

Config Port A Cat 5e connector on the rear of the unit is used for factory setup and diagnostics. SPECIFICATION

STATUS LEDS Height < 1U - 40mm (1.6’) Width 220mm (8.7’) Power AC Lights solid green when internal PSU is active. Depth 284mm (11.2’) Power DC Light solid green when Weight 2.0kg (4.4lbs) DC input valid. Flashes AC input power 100-240V AC, 0.30-0.13A RMS, 50/60Hz, when outside of range. Supply current - 0.13A @ 240V, 0.26A @ 115V, 0.30A @ 100V OK Flashes green DC input power 10 - 30V DC, 15VA max. heartbeat when Supply current - 1.25A @ 12V, 0.62A @ 24V connected and running. Fast flashing indicates Power 15W when fed DC boot/establishing dissipation 19.5W when fed 100-240V AC comms. (heat) Pri Sec RTR Light solid green when Operating 0-40 C valid connections have ambient air been made to the temperature Routers SFP ports. Pri Sec 1-4 Light solid green when DC INPUT CONNECTOR - 4 PIN XLR valid connections have been made to the Pin 1 - V DC 1 thru 4 I/O SFP ports. Pin 4 + V DC (10-30V) Sec (Split) Lights Yellow if Hub set to Sec in Split Mode • Unit connector is male, requiring a female termination on the connecting cable

CALREC Putting Sound in the Picture 45 I/O OPTIONS – FIXED FORMAT

AD5782 ANALOGUE MIC/LINE 12 IN/4 OUT – XLR

UNIT SPECIFICATIONS

Format Analogue Inputs 12 Mic / Line Level, Electronically Balanced Outputs 4 Line Level, Electronically Balanced (20 Hz–20 kHz Better than -35 dB, typically -45 dB Audio Connectors XLR (Inputs – Female, Outputs – Male) Input Gain Range -18 dB to +78 dB, remotely controlled per port Phantom Power 48 V, remotely controlled per port Input Impedance 2 kΩ @ Mic Level / 10 kΩ @ Line Level (auto-switching) Output Impedance <40 Ω Sensitivity -18 / -78 dB Mic / Line inputs Equivalent Input Noise -127 dB (150 Ω source) -1 dBFS @ 1 kHz – Better than 0.003% Distortion (input) -20 dBFS @ 1 kHz – Better than 0.006% -60 dBFS – Better than 0.3% Frequency Response (input) 20 Hz–20 kHz +/- 0.5 dB on Mic/Line inputs Frequency Response (output) 20 Hz–20 kHz +/- 0.25 dB Input CMR (Common Mode Rejection) >75 dB (Typical 85 dB) on Mic/Line inputs ADC / DAC 24 bit GPIO Compatible Yes (SW5739) Height 2U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc. rear mating connectors 12” (300 mm) Approximate Weight 11.5 lbs (5.2 kg) Input Power 100-240 V AC, 0.45-0.25 A RMS, 50/60 Hz Acoustic Noise 26 dB-SPL A-Weighted, 1 m from source

46 CALREC Product Catalogue AD5781 ANALOGUE MIC/LINE 24 IN/8 OUT – XLR

UNIT SPECIFICATIONS

Format Analogue Inputs 24 Mic / Line Level, Electronically Balanced Outputs 8 Line Level, Electronically Balanced (20 Hz–20 kHz Better than -35 dB, typically -45 dB Audio Connectors XLR (Inputs – Female, Outputs – Male) Input Gain Range -18 dB to +78 dB, remotely controlled per port Phantom Power 48 V, remotely controlled per port Input Impedance 2 kΩ @ Mic Level / 10 kΩ @ Line Level (auto-switching) Output Impedance <40 Ω Sensitivity -18 / -78 dB Mic / Line inputs Equivalent Input Noise -127 dB (150 Ω source) -1 dBFS @ 1 kHz – Better than 0.003% Distortion (input) -20 dBFS @ 1 kHz – Better than 0.006% -60 dBFS – Better than 0.3% Frequency Response (input) 20 Hz–20 kHz +/- 0.5 dB on Mic/Line inputs Frequency Response (output) 20 Hz–20 kHz +/- 0.25 dB Input CMR (Common Mode Rejection) >75 dB (Typical 85 dB) on Mic/Line inputs ADC / DAC 24 bit GPIO Compatible Yes (SW5739) Height 2U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc. rear mating connectors 12” (300 mm) Approximate Weight 12.5 lbs (5.7 kg) Input Power 100-240 V AC, 0.6-0.31 A RMS, 50/60 Hz Acoustic Noise 26 dB-SPL A-Weighted, 1 m from source

CALREC Putting Sound in the Picture 47 AD5780 ANALOGUE MIC/LINE 48 IN/16 OUT – XLR

UNIT SPECIFICATIONS

Format Analogue Inputs 48 Mic / Line Level, Electronically Balanced Outputs 16 Line Level, Electronically Balanced (20 Hz–20 kHz Better than -35 dB, typically -45 dB Audio Connectors XLR (Inputs – Female, Outputs – Male) Input Gain Range -18 dB to +78 dB, remotely controlled per port Phantom Power 48 V, remotely controlled per port Input Impedance 2 kΩ @ Mic Level / 10 kΩ @ Line Level (auto-switching) Output Impedance <40 Ω Sensitivity -18 / -78 dB Mic / Line inputs Equivalent Input Noise -127 dB (150 Ω source) -1 dBFS @ 1 kHz – Better than 0.003% Distortion (input) -20 dBFS @ 1 kHz – Better than 0.006% -60 dBFS – Better than 0.3% Frequency Response (input) 20 Hz–20 kHz +/- 0.5 dB on Mic/Line inputs Frequency Response (output) 20 Hz–20 kHz +/- 0.25 dB Input CMR (Common Mode Rejection) >75 dB (Typical 85 dB) on Mic/Line inputs ADC / DAC 24 bit GPIO Compatible Yes (SW5739) Height 4U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc. rear mating connectors 12” (300 mm) Approximate Weight 16.1 lbs (7.3 kg) Input Power 100-240 V AC, 1.05–0.51 A RMS, 50/60 Hz Acoustic Noise 27 dB-SPL A-Weighted, 1 m from source

48 CALREC Product Catalogue AE5743, AE5991, AE5992 ANALOGUE MIC/LINE 32 IN/32 OUT – EDAC Standard connector layout (AE5743), Alpha cabling compatible (AE5991) and 12 interfaces per connector (AE5992)

UNIT SPECIFICATIONS

Format Analogue Inputs 32 Mic / Line Level, Electronically Balanced Outputs 32 Line Level, Electronically Balanced (20 Hz–20 kHz Better than -35 dB, typically -45 dB Audio Connectors EDAC Input Gain Range -18 dB to +78 dB, remotely controlled per port Phantom Power 48 V, remotely controlled per port Input Impedance 2 kΩ @ Mic Level / 10 kΩ @ Line Level (auto-switching) Output Impedance <40 Ω Sensitivity -18 / -78 dB Mic / Line inputs Equivalent Input Noise -127 dB (150 Ω source) -1 dBFS @ 1 kHz – Better than 0.003% Distortion (input) -20 dBFS @ 1 kHz – Better than 0.006% -60 dBFS – Better than 0.3% Frequency Response (input) 20 Hz–20 kHz +/- 0.5 dB on Mic/Line inputs Frequency Response (output) 20 Hz–20 kHz +/- 0.25 dB Input CMR (Common Mode Rejection) >75 dB (Typical 85 dB) on Mic/Line inputs ADC / DAC 24 bit GPIO Compatible Yes (SW5739) Height 3U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc. rear mating connectors 12” (300 mm) Approximate Weight 11.5 lbs (5.2 kg) Input Power 100-240 V AC, 1.05-0.51 A RMS, 50/60 Hz Acoustic Noise 27 dB-SPL A-Weighted, 1 m from source

CALREC Putting Sound in the Picture 49 JB5606 DIGITAL AES3 16 IN/16 OUT – BNC

UNIT SPECIFICATIONS

Format Digital AES3 unbalanced Inputs 16 Outputs 16 Audio Connectors BNC Impedance 75 Ω Input Signal Range 0.3–1.2 V Pk–Pk Output Signal 1 V Pk–Pk (nominal) Signal to Noise Ratio (SNR) 22 Hz to 20 kHz – Better than -120 dB Digital to Digital (AES3) Distortion -1 dBFS, 20 Hz to 10 kHz – Better than 0.0001% Digital to Digital (AES3 with SRC) -1 dBFS, 20 Hz to 10 kHz – Better than 0.0002% Distortion Fader Off Isolation 22 Hz to 22 kHz – Better than -132 dB Sample rate conversion (SRC) 24-Bit switchable on all AES inputs SRC THD+N -117 dB @ 1 kHz, 0.00014% GPIO compatible Yes (SW5739) Height 2 U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc rear mating connectors 12” (300 mm) Approx Weight 8.6 lbs (3.9 kg) Input Power 100–240 V AC, 0.24–0.13 A RMS, 50/60 Hz Acoustic Noise 26 dB-SPL A-Weighted, 1 m from source

50 CALREC Product Catalogue JB5783 DIGITAL AES3 32 IN/32 OUT – BNC

UNIT SPECIFICATIONS

Format Digital AES3 unbalanced Inputs 32 Outputs 32 Audio Connectors BNC Impedance 75 Ω Input Signal Range 0.3–1.2 V Pk–Pk Output Signal 1 V Pk–Pk (nominal) Signal to Noise Ratio (SNR) 22 Hz to 20 kHz – Better than -120 dB Digital to Digital (AES3) Distortion -1 dBFS, 20 Hz to 10 kHz – Better than 0.0001% Digital to Digital (AES3 with SRC) -1 dBFS, 20 Hz to 10 kHz – Better than 0.0002% Distortion Fader Off Isolation 22 Hz to 22 kHz – Better than -132 dB Sample rate conversion (SRC) 24-Bit switchable on all AES inputs SRC THD+N -117 dB @ 1 kHz, 0.00014% GPIO compatible Yes (SW5739) Height 3 U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc rear mating connectors 12” (300 mm) Approx Weight 14.3 lbs (6.5 kg) Input Power 100–240 V AC, 0.38–0.20 A RMS, 50/60 Hz Acoustic Noise 26 dB-SPL A-Weighted, 1 m from source

CALREC Putting Sound in the Picture 51 JB5962 DIGITAL AES3 REAR MOUNT 32 IN/32 OUT - BNC

UNIT SPECIFICATIONS

Format Digital AES3 unbalanced Inputs 32 Outputs 32 Audio Connectors BNC Impedance 75 Ω Input Signal Range 0.3–1.2 V Pk–Pk Output Signal 1 V Pk–Pk (nominal) Signal to Noise Ratio (SNR) 22 Hz to 20 kHz – Better than -120 dB Digital to Digital (AES3) Distortion -1 dBFS, 20 Hz to 10 kHz – Better than 0.0001% Digital to Digital (AES3 with SRC) -1 dBFS, 20 Hz to 10 kHz – Better than 0.0002% Distortion Fader Off Isolation 22 Hz to 22 kHz – Better than -132 dB Sample rate conversion (SRC) 24-Bit switchable on all AES inputs SRC THD+N -117 dB @ 1 kHz, 0.00014% GPIO compatible No Height 3 U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc rear mating connectors 12” (300 mm) Approx Weight 14.3 lbs (6.5 kg) Input Power 100–240 V AC, 0.38–0.20 A RMS, 50/60 Hz Acoustic Noise 26 dB-SPL A-Weighted, 1 m from source

52 CALREC Product Catalogue JM5736, JM5831, JM5890 DUAL MADI

UNIT SPECIFICATIONS

Format MADI (AES10) Inputs 2 x MADI (2 x 64 / 56 channels) Outputs 2 x MADI (2 x 64 / 56 channels) BNC and: JM5736 – Multimode SC Fibre Audio Connectors JM5831 – Singlemode SC Fibre JM5890 – Multimode ST Fibre GPIO compatible No Height 1 U Width 19” rackmount (483 mm) Depth 9” (230 mm) Depth inc. rear mating connectors 12” (300 mm) Approximate Weight 7.5 lbs (3.4 kg) Input Power 100–240 V AC, 0.20–0.12 A RMS, 50/60 Hz Acoustic Noise N/A – No fans fitted in this unit

CALREC Putting Sound in the Picture 53 I/O OPTIONS – MODULAR

Modular I/O boxes are 3U rack-mount Earthing modular I/O fan speed is varies depending enclosures with 20 I/O card slots Chassis earth studs are fitted to each on the temperature within the box. that can be populated with a mixed PSU cover. These should be connected range of I/O cards, allowing for a to ground using earth cable of at least Hydra2 interface card custom selection of I/O quantities 6mm2 cross-section (10 AWG). The central card slot of a modular I/O box and formats. is reserved for a Hydra2 interface card. Airflow and mounting This card connects the I/O to a Hydra2 Modular I/O boxes connect to a Hydra2 The unit is a 19” rack-mount enclosure network. Unlike fixed format I/O, the network in the same way as Fixed Format designed for mounting into standard Hydra2 interface connectors are on the I/O. Multiple modular I/O boxes can equipment bays. Rear/side supports front of the modular I/O box. coexist on a Hydra2 network alongside should be considered in order to avoid fixed format I/O if required in order to excessive stress on the front racking Two Hydra2 interface ports are provided make up the total quantity of I/O in the angles, particularly if fitted into a mobile for redundancy—port 1 connects to format and location it is needed. installation. a primary Calrec router, port 2 to the secondary router in the same core. The Power A recessed air-intake grill runs across Hydra2 interface is via pluggable SFP Each modular I/O box is fitted with 2 the bottom of the box. The box can be modules, the correct type of SFP should x rear mounted AC PSUs, each with mounted directly under, or on top of be ordered to match the installation their own AC IEC input operating from another unit or surface—the recessed requirements—Cat5e copper, singlemode, 100–240V AC 50/60 Hz. Either PSU design of the intake allows sufficient air to or mulitmode fibre. Please refer to can power the whole box, two are fitted be drawn in from the sides (see diagram) the section on SFPs in the Installation in order to provide redundancy. Where to cool the box. Both side facing inlets manuals for more detail. possible, each PSU should be fed from should be left unobstructed. a separate AC source in order to provide The table on the following page provides redundancy against both PSU failure, Low noise fans fitted to the PSU modules an overview of the modular I/O cards and external AC mains loss. Input power pull air through the box, venting to the which are currently available. More (maximum) 100–240 VAC, 1.52–0.68A rear. To minimize fan noise and longevity, detailed information is provided in the RMS, 50/60 Hz. following sections.

293mm

Secondary air entry via card fronts Card Frame PSU Module Air exit via fans

65mm 63mm

Primary air entry

54 CALREC Product Catalogue Card Type Code Connector Type Inputs Outputs 8 Analogue Line Inputs AD5838 D-Type 8 0 8 Analogue Mic/Line Inputs AD6057 D-Type 8 0 4 Mic/Line Inputs AD5840 XLR 4 0 2 Mic/Line Inputs + Splits AL5870 XLR 2 2 Waves Soundgrid BI6218 RJ45 64 64 Dante with Network Redundancy BI6192 RJ45 64 64 8 Analogue Line Outputs DA5839 D-Type 0 8 4 Analogue Line Outputs DA5867 XLR 0 4 4 Digital AES Inputs Unbalanced JB5860 BNC 4 0 4 Digital AES Inputs Balanced JX5869 XLR 4 0 8 Inputs, 8 Outputs Digital AES JD5842 D-Type 8 8 4 Digital AES Outputs Unbalanced JB5837 BNC 0 4 4 Digital AES Outputs Balanced JX5868 XLR 0 4 MADI AES 10 JM6199 BNC+SFP 64/56 64 2 x SDI Embedder VI5872 BNC 2 2 2 x SDI De-Embedder VO5841 BNC 2 2 GPIO 8 Inputs, 8 Full Changeover Outputs WY5858 D-Type 8 8 GPIO 8 Inputs, 16 Outputs WY5859 D-Type 8 16 Blanking Plate NN5866 N/A N/A N/A

Modular I/O boxes can be recessed if required:

165.30 133.50 229.45 197.65 297.95 365.85

CALREC Putting Sound in the Picture 55 AD5838 8 X ANALOGUE LINE LEVEL INPUTS (D-TYPE)

The AD5838 provides 8 balanced line FRONT PANEL VIEW WIRING INFORMATION level analogue inputs to the Hydra2 network in a 1 slot-wide module. 37 Pin Male D-Type - Wiring side of connecting cable

The audio interface is via a 37 pin 20 37 female D-Type connector.

Front panel LEDs indicate audio signal 1 19 presence for each input, lighting green for signals above -60dBFS. Function Pin + 21 The standard modular I/O status LED In 1 - 3 Ground 2 flashes green once the card has booted + 23 and lights solid green once a connection In 2 - 5 between the card and the Hydra2 Ground 4 interface has been established. + 25 In 3 - 7 Ground 6 + 27 In 4 - 9 Ground 8 + 29 In 5 - 11 Ground 10 + 31 In 6 - 13 Ground 12 + 33 In 7 - 15 Ground 14 + 35 In 8 - 17 Ground 16 Ground 18, 20, 36 • Card connector is female, requiring male terminated interface cabling.

SPECIFICATION

Format Analogue Type Balanced Line Level Inputs 8 Outputs N/A Input Impedance 10 kΩ ADC 24 bit

56 CALREC Product Catalogue AD6057 8 X ANALOGUE MIC / LINE LEVEL INPUTS (D-TYPE)

The AD6057 provides 8 balanced FRONT PANEL VIEW WIRING INFORMATION mic / line level analogue inputs to the Hydra2 network in a 1 slot-wide 37 Pin Male D-Type - Wiring side of connecting cable module. The audio interface is via a 20 37 37 pin female D-Type connector.

Front panel LEDs indicate audio signal 1 19 presence for each input, lighting green for signals above -60dBFS. Function Pin + 21 The standard modular I/O status LED In 1 - 3 Ground 2 flashes green once the card has booted + 23 and lights solid green once a connection In 2 - 5 between the card and the Hydra2 Ground 4 interface has been established. + 25 In 3 - 7 Ground 6 + 27 In 4 - 9 Ground 8 + 29 In 5 - 11 Ground 10 + 31 In 6 - 13 Ground 12 + 33 In 7 - 15 Ground 14 + 35 In 8 - 17 Ground 16 Ground 18, 20, 36 • Card connector is female, requiring male terminated interface cabling.

SPECIFICATION

Format Analogue Type Balanced Mic/Line Level Inputs 8 Outputs N/A Input Gain Range -18dB to +78dB, remotely controlled per input Phantom Power 48V remotely switchable per input Input Impedance 5 kΩ ADC 24 bit

CALREC Putting Sound in the Picture 57 AD5840 4 X MIC/LINE IN (XLR)

The AD5840 provides 4 balanced FRONT PANEL VIEW WIRING INFORMATION mic / line level analogue inputs to Connector side Wiring Side the Hydra2 network in a 2 slot-wide Function Pin module. The audio interface is via 4 o 2

2 1 1 2 3 female XLR connectors. Female 3 3 Ground 1 Front panel LEDs indicate audio signal presence for each input, lighting green for signals above -60dBFS. 1 2 2 1 Male 3 3 Each input also has front panel LED indicators which light red when 48 V phantom power is on. • Card connectors are female, requiring male terminated interface cabling. The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection between the card and the Hydra2 interface has been established.

SPECIFICATION

Format Analogue Type Balanced Mic/Line Level Inputs 4 Outputs 0 -18 dB to +78 dB, remotely controlled per Input Gain Range input Phantom Power 48 V remotely switchable per input 2 kΩ @ Mic Level / 10 kΩ @ Line level Input Impedance (auto-switching) ADC 24 bit

58 CALREC Product Catalogue AL5870 2 X MIC/LINE IN WITH SPLITS (XLR)

The AL5870 provides 2 balanced mic FRONT PANEL VIEW WIRING INFORMATION / line level analogue inputs to the Connector side Wiring Side Hydra2 network along with a pre-gain Function Pin analogue ‘split’ output for each input o 2

2 1 1 2 3 in a 2 slot-wide module. The 2 Input Female 3 3 connectors are female XLR, the 2 Ground 1 ‘split’ outputs are male XLR.

The pre gain analogue split outputs are 1 2 2 1 active, irrespective of the Hydra2 interface Male 3 3 card status, as long as the I/O box is powered. • Card input connectors are female, requiring male terminated interface Front panel LEDs indicate audio signal cabling. presence for each input and split output, lighting green for signals above -60dBFS. • Card Split output connectors are male, requiring female terminated interface cabling. Each input also has front panel LED indicators which light red when 48V phantom power is on.

This module supports phantom power detection, allowing for power to the mic input to be controlled by the device being fed from the split output. This feature is enabled per input / split using PCB mounted DIP switches fitted to the card. When active, if +24V DC or greater is detected on a split output (i.e. phantom power is being fed by the device connected to the split), the card will automatically switch its own phantom power to the corresponding mic input. If phantom power has been switched in this way, the 48 V LED indicator will briefly blink off approximately every two seconds. SPECIFICATION

The standard modular I/O status LED Format Analogue flashes green once the card has booted Type Balanced Mic/Line Level and lights solid green once a connection Inputs 2 between the card and the Hydra2 interface has been established. Outputs 2 (Pre-gain input splits) -18 dB to +78 dB, remotely controlled per Input Gain Range input Phantom Power 48 V remotely switchable per input 2 kΩ @ Mic Level / 10 kΩ @ Line level Input Impedance (auto-switching) ADC 24 bit

CALREC Putting Sound in the Picture 59 BI6218 WAVES SOUNDGRID (RJ45)

The BI6218 provides 64 outputs from FRONT PANEL VIEW the Hydra 2 network to the SoundGrid network, and 64 inputs to Hydra 2 from SoundGrid at 48 kHz via a single Ethernet cable. .

SoundGrid is an Audio-over-Ethernet networking and processing technology developed by Waves. SoundGrid provides extremely low-latency, high-channel-count audio processing using standard Intel CPUs and 1 Gbps Ethernet networks for studio, live sound, and other real-time professional audio applications.

Real-time audio processing is performed on standard Intel-based plug-in servers, running a Waves-customised real-time version of Linux.

For more information please go to:- http://www.waves.com/soundgrid-systems

SPECIFICATION

Format Digital Type SoundGrid Connector RJ45 Inputs 64 Outputs 64

60 CALREC Product Catalogue BI6192 DANTE WITH NETWORK REDUNDANCY (RJ45)

The BI6192 provides an interface for FRONT PANEL VIEW routing audio in and out of a Hydra2 network into a Dante network. The interface is via RJ45 connectors housed within a 1-slot wide module.

Dante is a self-configuring, plug and play, networking technology developed by Audinate. Dante uses standard internet protocols. The Calrec Dante modular I/O card operates over Gigabit (Giga/E) Ethernet.

The BI6192 provides 64 input channels and 64 output channels (for a Dante network operating at 48 kHz or 44.1 kHz) or 32 input channels and 32 output channels (for a Dante network operating at 96 kHz) sample-rate converted down to 48kHz with the SRC’s permanently enabled on all channels.

Two RJ45 ports (primary and secondary) are provided to give full redundancy on the Dante portion of the network.

For more information please see Audinate’s Dante documentation here www.audinate.com/resources/technical- documentation.

SPECIFICATION

Format Digital Type Dante Connector RJ45 Inputs 64 (at 48 kHz or 44.1 kHz), 32 (at 96 kHz) Outputs 64 (at 48 kHz or 44.1 kHz), 32 (at 96 kHz)

CALREC Putting Sound in the Picture 61 DA5839 8 X ANALOGUE LINE OUT (D-TYPE)

The DA5839 provides 8 balanced FRONT PANEL VIEW WIRING INFORMATION analogue line level outputs from the Hydra2 network in a 1 slot-wide 37 Pin Female D-Type - Wiring side of connecting cable module. The audio interface is via a 37 20 37 pin male D-Type connector.

Front panel LEDs indicate audio signal 19 1 presence for each output, lighting green Function Pin for signals above -60dBFS. + 21 Out 1 - 3 The standard modular I/O status LED Ground 2 flashes green once the card has booted + 23 and lights solid green once a connection Out 2 - 5 between the card and the Hydra2 Ground 4 interface has been established. + 25 Out 3 - 7 Ground 6 + 27 Out 4 - 9 Ground 8 + 29 Out 5 - 11 Ground 10 + 31 Out 6 - 13 Ground 12 + 33 Out 7 - 15 Ground 14 + 35 Out 8 - 17 Ground 16 Ground 18, 20, 36 • Card connector is male, requiring female terminated interface cabling.

SPECIFICATION

Format Analogue Type Balanced Line Level Inputs N/A Outputs 8 Output Impedance <40 Ω DAC 24 bit

62 CALREC Product Catalogue DA5867 4 X LINE OUT (XLR)

The DA5867 provides 4 balanced FRONT PANEL VIEW WIRING INFORMATION analogue line level outputs from Connector side Wiring Side the Hydra2 network in a 2 slot-wide Function Pin module. The audio interface is via the o 2

2 1 1 2 3 4 male XLR connectors. Female 3 3 Ground 1 Front panel LEDs indicate audio signal presence for each output, lighting green for signals above -60 dBFS. 1 2 2 1 Male 3 3 The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection • Card connector is male, requiring between the card and the Hydra2 female terminated interface cabling. interface has been established.

SPECIFICATION

Format Analogue Type Balanced Line Level Inputs 0 Outputs 4 Output Impedance <40 Ω DAC 24 bit

CALREC Putting Sound in the Picture 63 JB5860 4 X DIGITAL AES INPUT (BNC)

The JB5860 provides 4 unbalanced FRONT PANEL VIEW digital AES3 inputs to the Hydra2 network in a 1 slot-wide module. The audio interface is via the 4 BNC connectors.

Front panel LEDs indicate AES signal presence for each input, lighting green when receiving a valid AES carrier signal (irrespective of audio content).

Each input also has an ‘SRC’ LED indicator which lights yellow when the sample rate convertor is active.

The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection between the card and the Hydra2 interface has been established.

SPECIFICATION

Format Digital Type AES3 (75 Ω unbalanced) Input Range 0.3V-1.2V Pk-Pk Audio Connector BNC Inputs 4 SRC 24 bit, remotely switchable per input.

64 CALREC Product Catalogue JX5869 4 X DIGITAL AES INPUT (XLR)

The JB5896 provides 4 balanced FRONT PANEL VIEW WIRING INFORMATION digital AES3 inputs to the Hydra2 Connector side Wiring Side network in a 2 slot-wide module. The Function Pin audio interface is via the 4 female XLR o 2

2 1 1 2 3 connectors. Female 3 3 Ground 1 Front panel LEDs indicate AES signal presence for each output, lighting green when receiving a valid AES carrier signal 1 2 2 1 (irrespective of audio content). Male 3 3

Each input also has an ‘SRC’ LED indicator which lights yellow when the • Card connector is female, requiring sample rate convertor is active. male terminated interface cabling.

The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection between the card and the Hydra2 interface has been established.

SPECIFICATION

Format Digital Type AES3 (110 Ω balanced) Input Range 0.2 V - 7.0 V Pk-Pk Audio Connector Female XLR Inputs 4 SRC 24 bit, remotely switchable per input.

CALREC Putting Sound in the Picture 65 JD5842 8 IN, 8 OUT DIGITAL AES (D-TYPE)

The JD5842 balanced digital AES3 INPUT WIRING INFORMATION OUTPUT WIRING INFORMATION card provides 8 inputs and 8 outputs to / from the Hydra2 network in a 1 25 Pin Male D-Type - Wiring side of connecting cable 25 Pin Female D-Type - Wiring side of connecting cable slot-wide module. Audio interfacing 14 15 16 17 18 19 20 21 22 23 24 25 25 24 23 22 21 20 19 18 17 16 15 14 is via the 2, 25 pin D-Type connectors, female for inputs, male for outputs. 1 2 3 4 5 6 7 8 9 10 11 12 13 13 12 11 10 9 8 7 6 5 4 3 2 1

The standard modular I/O status LED Function Pin Function Pin flashes green once the card has booted + 14 + 14 and lights solid green once a connection nut 1 - 2 Out 1 - 2 between the card and the Hydra2 Ground 1 Ground 1 interface has been established. + 3 + 3 nut 2 - 16 Out 2 - 16 Ground 15 Ground 15 + 17 + 17 FRONT PANEL VIEW nut 3 - 5 Out 3 - 5 Ground 4 Ground 4 + 6 + 6 nut 4 - 19 Out 4 - 19 Ground 18 Ground 18 + 20 + 20 nut 5 - 8 Out 5 - 8 Ground 7 Ground 7 + 9 + 9 nut 6 - 22 Out 6 - 22 Ground 21 Ground 21 + 23 + 23 nut 7 - 11 Out 7 - 11 Ground 10 Ground 10 + 12 + 12 nut 8 - 25 Out 8 - 25 Ground 24 Ground 24 Ground 13 Ground 13 • Input connector is female, requiring • Output connector is male, requiring male terminated interface cabling. female terminated interface cabling.

SPECIFICATION

Format Digital Type AES3 (110 Ω balanced) Input Range 0.2 V - 7.0 V Pk-Pk Output Voltage 3.5 V nominal into 110 Ω Inputs - 25 pin female D-Type Audio Connectors Outputs - 25 pin Male D-Type Inputs 8 Outputs 8 SRC 24 bit, remotely switchable per input.

66 CALREC Product Catalogue JB5837 4 X DIGITAL AES OUTPUT (BNC)

The JB5837 provides 4 unbalanced FRONT PANEL VIEW digital AES3 outputs from the Hydra2 network in a 1 slot-wide module. The audio interface is via the 4 BNC connectors.

Front panel LEDs indicate audio presence for each output, lighting green when outputting signal over -60 dBFS.

The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection between the card and the Hydra2 interface has been established.

SPECIFICATION

Format Digital Type AES3 (75 Ω unbalanced) Output 1 V Pk-Pk nominal into 75 Ω Audio Connector BNC Outputs 4

CALREC Putting Sound in the Picture 67 JX5868 4 X DIGITAL AES OUTPUT (XLR)

The JX5868 provides 4 balanced FRONT PANEL VIEW WIRING INFORMATION digital AES3 outputs from the Hydra2 Connector side Wiring Side network in a 1 slot-wide module. Function Pin The audio interface is via the 4 XLR o 2

2 1 1 2 3 connectors. Female 3 3 Ground 1 Front panel LEDs indicate audio presence for each output, lighting green when outputting signal over -60 dBFS. 1 2 2 1 Male 3 3 The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection • Card connector is male, requiring between the card and the Hydra2 female terminated interface cabling. interface has been established.

SPECIFICATION

Format Digital Type AES3 (110 Ω unbalanced) Output 3.5 V Pk-Pk nominal into 110 Ω Audio Connector XLR Outputs 4

68 CALREC Product Catalogue JM6199 1 X MADI IN/OUT-AES10 (BNC / SFP)

The JM6199 provides 1 x MADI input FRONT PANEL VIEW stream plus 1 x MADI output stream with independently switchable sample rate converters for both input and output.

The front panel LED provides indication for receiving a valid MADI input and for sample rate converters being active.

Input sources are selectable between BNC copper and SFP. Both BNC and SFP outputs are fed simultaneously with the same signal.

A range of SFPs are available, see Connection Information from page 30 for more details.

SPECIFICATION

Format Digital Type MADI (AES 10) Input 1 x 64/56 channel input stream (at 48KHz) Output 1 x 64 channel output stream (at 48KHz) Audio Connector BNC+SFP

CALREC Putting Sound in the Picture 69 VI5872 2 X SDI EMBEDDER (BNC)

The VI5872 provides 2 SDI outputs, Maximum channel count FRONT PANEL VIEW into which audio can be embedded As Hydra2 links are limited to 512 from the Hydra2 network. This is a 1 channels of audio in each direction, each slot-wide module with SDI interfacing I/O box can be populated with cards that via BNC connectors. provide a maximum of 512 input channels, and 512 output channels. Any console, H2O user or 3rd party SW- P-08 controller on the Hydra2 network This limitation becomes a factor when a can select audio to be embedded into the large number of SDI cards are fitted in SDI outputs. Each SDI output can carry the same modular I/O box. Channels are up to 16 channels of embedded audio. counted across the card slots from left to right. If, for example, SDI embedder (audio Each SDI output is paired with an SDI output) cards are fitted in the first 16 card input. A valid SDI signal must be fed slots, the output channel count will be at into an input connector in order for the its maximum (16 channels of audio per corresponding output to function. The SDI output x 2 SDI outputs per card x 16 output can only pass video content from cards = 512 channels) - Any output cards its corresponding input—video content fitted in the remaining 4 slots will not pass cannot be re-routed by the Hydra2 audio or GPIO signals, irrespective of system. Any audio in the incoming SDI whether audio is being routed to any or all signal is stripped and discarded—all audio of the SDI outputs. The remaining card in the output stream is routed from the slots could however be fitted with input Hydra2 network. Audio channels within cards as inputs and outputs have separate the output stream will be silent unless channel count quotas. Hydra2 patches are made to them. If any of the audio content from the SDI input Note, the channel count totals mono audio needs to be maintained, the signal should channels, therefore, each SDI stream has first pass through a de-embedder card a channel count of 16 and each digital (VO5841 / VO5873). AES port has a channel count of 2.

3rd party EMBER controllers, such as L-S-B’s VSM and Colledia’s BNCS have the ability to insert SMPTE2020 metadata into each SDI output stream’s VANC space. SPECIFICATION Front panel LEDs for each input will light up green to indicate a valid SDI signal is Format SDI being received. Type SD / HD / 3G SDI Connector BNC The standard modular I/O status LED Outputs 2 x SDI (16 audio channels each) flashes green once the card has booted and lights solid green once a connection Inputs 2 x SDI in (audio discarded) between the card and the Hydra2 interface has been established.

70 CALREC Product Catalogue VO5841 2 X SDI DE-EMBEDDER (BNC)

The VO5841 provides 2 SDI inputs, SDI output x 2 SDI outputs per card x 16 FRONT PANEL VIEW the audio from which can be de- cards = 512 channels). embedded and distributed across the Hydra2 network. This is a 1 slot-wide Any input cards fitted in the remaining 4 module with SDI interfacing via BNC slots will not pass audio or GPIO signals, connectors. irrespective of whether audio is being used from any or all of the SDI inputs. All 16 channels of audio can be de- The remaining card slots could however embedded from SD, HD or 3G SDI be fitted with output cards as inputs and signals. outputs have separate channel count quota’s. Note, the channel count totals For each SDI input, there is an SDI ‘thru’ mono audio channels and therefore each connector which passes on the incoming SDI stream has a channel count of 16 and SDI signal, unchanged, with its original each digital AES port has a channel count audio channels included. of 2.

Front panel LEDs for each input light up green to indicate a valid SDI signal is being received.

The standard modular I/O status LED flashes green once the card has booted and lights solid green once a connection between the card and the Hydra2 interface has been established.

Maximum channel count As Hydra2 links are limited to 512 channels of audio in each direction, each I/O box can be populated with cards that provide a maximum of 512 input channels, and 512 output channels. When counting inputs and outputs GPIO ports must also be included.

This limitation becomes a factor when a SPECIFICATION large number of SDI cards are fitted in the same modular I/O box. Channels are Format SDI counted across the card slots from left to Type SD / HD / 3G right. If, for example, SDI de-embedder SDI Connector BNC (audio input) cards are fitted in the first 16 Inputs 2 x SDI (16 audio channel in each) card slots, the input channel count will be at its maximum (16 channels of audio per Outputs 2 (SDI ‘Thru’)

CALREC Putting Sound in the Picture 71 WY5858 GPIO, 8 IN / 8 FULL CHANGEOVER OUT (D-TYPE)

GPIO cards can be fitted to provide FRONT PANEL VIEW INPUT WIRING EXAMPLE GP INPUT #1 General Purpose interfacing for logic control such as remote / fader WY5858 starts for playback devices, triggering +5V autofades on a control surface, and much more. 17 GP Input #1 Trigger Access to each general purpose input and 1 output can be given to any console on the Hydra2 network.

The function of each general purpose External 34 Closure input and output is configurable and assignable from any Apollo/Artemis/ 50 Summa console which has been granted access.

This is a one slot wide module. Inputs and outputs are all on 1 x female 50 pin D-type connector.

LEDs The Status LED strobes to indicate that the local software is running. The LED illuminates solidly when connection is established to the Hydra2 Interface Module in the same modular I/O chassis.

GP Inputs 8 opto-isolated inputs allow for remote control of console functions. Applying between 3 and 50 Volts, AC or DC across the + & - pins of the opto will trigger them. GP INPUT PINS GP OUTPUT PINS 50 Pin Male D-Type - Wiring side of connecting cable Function Pin If using a dry closure to trigger a GP 34 50 NO 39 input, note that the incoming closure GPO 1 NC 7 18 33 should be wired to one side of an opto Common 23, 40 input only. The other side of the opto 1 17 NO 24 should be pulled up by linking it to the 5V GPO 2 NC 41 pin on the connector. The other side of Function Pin Common 8, 25 + 1 NO 9 the closure should be wired to the 0V pin. GPI 1 An example of wiring a closure to GP - 34 GPO 3 NC 26 + 18 Common 42, 10 input #1 is shown above right. GPI 2 - 2 NO 43 + 35 GPO 4 NC 11 GP Outputs GPI 3 - 19 Common 27, 44 The WY5858 version provides 8 + 3 NO 28 GPI 4 changeover relays with access to both - 36 GPO 5 NC 45 the normally open, and normally closed + 20 Common 12, 29 GPI 5 contacts for each. A closure pair is - 4 NO 13 achieved by wiring one leg to either NO or + 37 GPO 6 NC 30 GPI 6 NC and the other leg to a common pin for - 21 Common 46, 14 + 5 NO 47 that specific relay. If external equipment GPI 7 requires a ground for activation, rather - 38 GPO 7 NC 15 + 22 Common 31, 48 than a closure, the common pin for that GPI 8 - 6 NO 32 relay should be connected to a ground Supply +5 V 17 GPO 8 NC 49 from the external equipment. Supply 0 V 50 Common 16, 33

72 CALREC Product Catalogue WY5859 GPIO, 8 IN / 16 OUT (D-TYPE)

GPIO cards can be fitted to provide FRONT PANEL VIEW General Purpose interfacing for logic control such as remote / fader starts for playback devices, triggering autofades on a control surface, and much more.

This is a one slot wide module. Inputs and outputs are all on 1 x female 50 pin D-type connector.

Access to each general purpose input and output can be given to any console on the Hydra2 network.

The function of each general purpose input and output is configurable and assignable via Apollo/Artemis/Summa console’s which have been granted access.

LEDs The Status LED strobes to indicate that the local software is running. The LED illuminates solidly when connection is established to the Hydra2 Interface GP OUTPUT PINS Module in the same modular I/O chassis. Function Pin NO + 39 GP Inputs GP 1 8 opto-isolated inputs allow for remote NO - 23 NO + 7 control of console functions. Applying GP 2 NO - 40 between 3 and 50 Volts, AC or DC across NO + 24 the + & - pins of the opto will trigger them. GP 3 GP INPUT PINS NO - 8 NO + 41 50 Pin Male D-Type - Wiring side of connecting cable GP 4 If using a dry closure to trigger a GP input, NO - 25 note that the incoming closure should 34 50 NO + 9 GP 5 NO - 42 be wired to one side of an opto input 18 33 NO + 26 only. The other side of the opto should GP 6 be pulled up by linking it to the 5V pin 1 17 NO - 10 NO + 43 on the connector. The other side of the GP 7 Function Pin NO - 27 closure should be wired to the 0V pin. An + 1 NO + 11 example of wiring a closure to GP input GPI 1 GP 8 - 34 NO - 44 #1 is shown on the previous page. + 18 NO + 28 GPI 2 GP 9 - 2 NO - 12 GP Outputs + 35 NO + 45 GPI 3 GP 10 The WY5859 version provides 16 - 19 NO - 29 normally open contact closure pairs. If + 3 NO + 13 GPI 4 GP 11 external equipment requires a ground for - 36 NO - 46 + 20 NO + 30 activation, rather than a closure, one side GPI 5 GP 12 of the relay should be connected to a - 4 NO - 14 + 37 NO + 47 ground from the external equipment and GPI 6 GP 13 - 21 NO - 31 the other side of the relay used as the + 5 NO + 15 GPI 7 GP 14 trigger. - 38 NO - 48 + 22 NO + 32 GPI 8 GP 15 - 6 NO - 16 Supply +5 V 17 NO + 49 GP 16 Supply 0 V 50 NO - 33

CALREC Putting Sound in the Picture 73 I/O OPTIONS – OTHER

AD6217-2 FIELDBOX 8 IN (XLR)/ 8 OUT ANALOGUE (D-TYPE) “TASCAM” STANDARD

FIELDBOX - FRONT VIEW

The Fieldbox provides 8 balanced Battery powered operation Note that SFP design varies depending analogue mic/line level inputs, and 8 The DC input is also suitable for use with on manufacturer, please ensure that SFPs balanced analogue line level outputs, batteries. Batteries can be used as a are correctly latched in place after fitting in a compact, cost-effective package. backup to the internal AC supply, or as them. In the event that a connection is the primary power source. There is no not automatically established after hot- Enclosure drain on the battery whilst the unit is fed plugging an SFP, please reset the unit the The Fieldbox is 220mm wide x 384mm with AC, yet switch-over from AC to DC is SFP is plugged in to. deep x 40mm (<1U) high. Threaded fixing seamless. holes in the base allow the unit to be Like all other Hydra2 I/O, the Fieldbox secured in place if required. System Status warnings are issued must be given an ID, unique amongst across the network and front panel LED all the I/O on the network, before being Cooling indication is provided if the battery level connected. The ID is a value from 1 to This is a fanless design that is cooled is low. 255, set as a binary representation using through natural convection and radiation. DIP switches accessible from the rear. If not being used in a cooled environment, A wide range of suitable batteries are please allow for 45mm (1.75’) clearance commonly available from broadcast For further guidance, please refer to the on the top and sides from other heat suppliers. Costs vary significantly based I/O Box Identification section, under Fixed generating equipment. on run time and other factors. Calrec Format I/O in the Hydra2 Installation recommends the use of Anton Bauer manual. Power G150 batteries in conjunction with their The Fieldbox contains a single AC mains QR-UNIV XLR mount to provide a runtime Another DIP switch accessible from the PSU that can be fed 100-240V AC via in excess of 12 hours. ‘Hot-swap’ battery rear sets whether the unit is to network via a rear mounted IEC connector. The IEC mounts are also available to fit 2 batteries Hydra2 or AoIP. Please ensure this switch connector has a retaining clip that can that can be individually swapped out is set to the Hydra2 position for normal hold some types of IEC cables in place. without interrupting operation. operation. The cable supplied with the unit has a built in latching mechanism and does not need The DC input is protected by ISO 7637-2 AoIP to be clipped in place. circuitry against surges, reverse polarity and other external power faults. A card slot within the unit will allow for A 10-30V DC input allows an optional future upgrades to AoIP networking. external PSU to be connected to provide Hydra2 network connection More information on AoIP connectivity power redundancy if required. A pair of rear mounted SFP slots provide will be provided when module options are primary and secondary connections for a available. Hydra2 network. Various fibre and copper SFP modules can be supplied.

74 CALREC Product Catalogue I/O OPTIONS – OTHER

FIELDBOX - REAR VIEW

STATUS LEDS SPECIFICATION

Power AC Lights solid green when Format Analogue, electronically balanced internal PSU is active. I/O 8 x Mic/line inputs + 8 x line level outputs. Power DC Light solid green when Input Gain -18 to +78dB, remotely controlled DC input valid. Flashes when outside of range. Phantom Power +48V remotely switchable OK Flashes green Input Impedance 5k heartbeat when Equiv I/P noise -126dBu connected and running. Fast flashing indicates Input distortion -1dBFS @ 1kHz - <0.004% boot/establishing -20dBFS @1kHz - <0.006% comms. -60dBFS @1kHz - <0.6% +48V One per input, lights Input CMR >80dB @1kHz solid red when phantom ADC/DAC 24 bit power switched on Output balance > 45 dB AoIP (Rear) Lights green if set to connect to a non Output impedance <40 Ohms Hydra2 network Pri / Sec Indicates network GPIO None SFP (Rear) activity Height < 1U - 40mm (1.6’) Width 220mm (8.7’) DC INPUT CONNECTOR - 4 PIN XLR Depth 384mm (15.2’) Pin 1 - V DC Weight 2.5kg (5.5lbs) Pin 4 + V DC (10-30V) AC input power 100-240V AC, 0.34-0.16A RMS, 50/60Hz, • Unit connector is male, the connecting Supply current - 0.16A @ 240V, 0.30A @ 115V, 0.34A @ 100V cable requires female termination. DC input power 10 - 30V DC, 20VA max. Supply current - 1.67A @ 12V, 0.83A @ 24V OUTPUT AUDIO CONNECTOR - 25 PIN Power dissipation 20W when fed DC D-TYPE, AES59 / ‘TASCAM’ STANDARD (heat) 24W when fed 115-240V AC, 24.5W @ 100V AC Signal Pins (+ , - , Gnd) Operating ambient 0-40 C O/P 1 24, 12, 25 air temperature O/P 2 10, 23, 11 Latency GSM O/P 3 21, 9, 22 Dynamic Range GSM O/P 4 7, 20, 8 Frequency GSM O/P 5 18, 6, 19 Response O/P 6 4, 17, 5 O/P THD GSM O/P 7 15, 3, 16 Headroom GSM O/P 8 1, 14, 2 • Unit connector is female, the connecting cable requires male termination.

CALREC Putting Sound in the Picture 75 DIGICO ORANGE BOX - HYDRA 2 INTERFACE

ORANGE BOX - FRONT VIEW

The Orange Box provides audio format conversion between any two of the ten available interfaces using DMI (DiGiCo Multichannel Interface) modules

The DMI-HYDRA 2 module interface DMI-HYDRA2 MODULE - FRONT PANEL for the Orange Box is shown right. It currently provides up to 56 Inputs and 56 Outputs when format converted to MADI using the DMI-MADI-B / DMI-MADI-C modules.

The DMI-MADI module is connected to the DiGiCo console allowing I/O to be passed between Calrec and DiGiCo domains along with exchange of labels in either direction.

The DMI bus interface carries up to 128 channels of audio in both directions and allows modules to be plugged in with power applied. using LED indication on the front of the modules. Module Enclosure The DMI-HYDRA 2 Module fits into one Fitting Modules of the module slots in the Orange Box. Currently the DMI-HYDRA 2 Module has to be fitted in the right hand slot (DMI 2) Hydra2 network connection of the Orange Box for sync purposes and A pair of front mounted SFP slots provide as a consequence the DMI-MADI Module primary and secondary connections for a is fitted in the left hand slot (DMI 1) of the Hydra2 redundant network. Various fibre Orange Box. When fitting the H2 Module and copper SFP modules can be supplied static protection wristbands should be for medium to long distances over worn to prevent ESD failures. Singlemode or Multimode fibre or CAT5e over Copper up to 90m. • Note that this requires V3.2 software or later to work correctly. Both Primary and Secondary interfaces show connectivity and active data status

76 CALREC Product Catalogue EG6266-2 AOIP INTERFACE

AOIP INTERFACE- FRONT VIEW

AOIP INTERFACE- REAR VIEW

Weight

The Calrec Audio over IP unit provides Hydra2 network connections The System OK LED strobes every a Hydra2 AoIP interface carrying up A pair of rear mounted SFP slots provide second to indicate that the system is to 512 x 512 channels using AES67/ primary and secondary connections back actively talking to the AoIP modules and and or AVB modules. to routers in a Hydra2 network. the Hydra 2 interface. or every 100ms if the Hydra 2 interface is not active. The unit can accommodate two modules Primary and Secondary SFP slots are AoIP 1 & AoIP 2 and may be fitted with also provided for the 2 x AoIP ports and Config Port one or two 256 x 256 channel AES67/ indicators are provided on the rear to A Cat 5e connector on the front of the Ravenna or AVB modules, or one of each show which modules have been fitted to unit is used for Setup via a WEB UI. type as required. the unit. Front Panel Reset & Status LEDs In addition to the standard Hydra2 The AoIP unit must be given an ID which A recessed Reset button allows the redundancy each module also has is unique on the network, before being user to reset the system. A Red Fan Fail both a primary and secondary 1GB IP connected. The ID is a value from 1 to LED illuminates if the fan stops spinning. connection, supporting hitless switching 256, set as a binary representation using Next to this are the 2 PSU LEDs which for redundancy. DIP switches accessible from the rear. illuminate green to show they are ON.

IP Stream management is achieved The AES sync O/P on the rear of the unit The Hydra2, AoIP 1 & AoIP 2 primary through a WEB UI. provides a PTP clock reference derived and secondary interface LEDs illuminate from the Internet stream. Note: this sync to show they are connected. Enclosure O/P is not yet enabled as of 01/09/16. The AoIP interface unit is 440mm wide x SPECIFICATION 225mm deep x 44mm (<1U) high. STATUS LEDS Height < 1U - 44mm (1.73’) Cooling AES67/AVB Lights to show modules Width 19” Rackmount (483mm) are installed. The unit has a single ultra low noise Depth 225mm (8.9’) inc BNC fan. Air is drawn in from the right and System OK Flashes heartbeat extracted from the rear, please allow at every second when Weight 3.13kg (6.9lbs) least 25mm (1’) clearance at the right connected and running. AC input 100-240V AC, 50/60Hz, a n d r e a r o f t h e u n i t f o r o p e r a t i o n u p t o Fast flashing indicates power 0.35-0.18A RMS, no comms with Hydra 2. 40 deg C (104 deg F) ambient Supply current - temperature. Fan Fail Lights Red to show fan 0.18A @ 240V, not spinning. 0.30A @ 115V, 0.35A @ 100V Power PSU 1 & 2 Light solid green when The AoIP unit contains dual AC mains PSU working. Power 26.0W @ 100-240V AC Dissipation PSUs for redundancy that can be fed Hydra2 Light solid green when (Heat) 100-240V AC via rear mounted IEC Pri & Sec valid connections made connectors. The IEC connectors have a to Hydra2 SFP ports. Operating 0-40 C retaining clip that can hold some types of AoIP 1 & 2 Lights solid green when ambient air IEC cables in place. The cable supplied Pri & Sec valid connections made temperature with the unit should be clipped in place. to AoIP1 & 2 SFP ports.

CALREC Putting Sound in the Picture 77 AD6300 EXTERNAL I/O RACK FOR BRIO 36

BR-IO is a 4U Hydra2 based external Port Patching Identification Hydra2 interfacing I/O Rack allowing for cost effective The BR-IO has it’s own ICON which The interface controller on the right hand expansion of I/O for use with Brio appears in the I/O Boxes patching side of the front panel of the unit connects 36 consoles. pages. The analogue inputs and outputs the I/O to the optional Hydra2 module in are prefixed by the Letter ‘A’ in the port a Brio 36 system either directly or via a It is intended to be placed in control/ patching pages and the digital inputs and H2Hub. equipment rooms, trucks, studios, and outputs are prefixed by the letter ‘B’ for even outdoor use providing the user patching purposes. Two Hydra2 ‘Light’ based interface ports provides appropriate protection against are provided on the BR-IO for redundancy: the elements (flight-cases / covers / For example, where the box ID is set to Port 1 connects to the Primary H2 general protection). 434 then Analogue Mic/Line Input 3 connection on a Brio 36, Port 2 connects This rack has the same complement of would be identified as 434A-03. See to the Secondary Hydra 2 connection on analogue and digital I/O that can be found below for a I/O Box / Port Patching the same Brio 36. Multiple BR-IO units in a Brio 36 system. example. may be added via a H2 Hub along with other I/O boxes from the Hydra2 range. External I/O Rack Audio Interfaces The image below shows the BR-IO rack Hydra2 based network components and the Audio interfaces available to the interface via pluggable SFP modules, the user from this I/O Rack are:- correct type of SFP should be ordered to BR-IO PORT PATCHING EXAMPLE match the installation requirements. 24 x Analogue Mic/Line I/Ps, 16 x Analogue Line O/Ps, 8 x Digital AES I/Ps, with SRC, 8 x Digital AES O/Ps.

The Audio Specifications for the Analogue and Digital inputs and outputs are the same as those built-in to the Brio 36.

AD6300 - BR-IO EXTERNAL I/O RACK.

78 CALREC Product Catalogue BLUEFIN2 CUSTOMERS

CALREC Putting Sound in the Picture 79 Calrec Audio Ltd Nutclough Mill Hebden Bridge West Yorkshire England UK HX7 8EZ

Tel +44 (0)1422 842159 Fax +44 (0)1422 845244 Email [email protected] calrec.com (926-202 Iss4)