Exploration of the fluorescent properties and the modulated activities against sirtuin fluorogenic assays of chromenone-derived natural products

Hui Wen1,†, Nina Xue1,†, Feng Wu2, Yujun He1, Gang Zhang1, Zebin Hu3,*, and Huaqing Cui1,*

1 State Key Laboratory of Bioactive Substances and Function of Natural Medicine, Institute of Materia Medica, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100050, China; [email protected]; [email protected]; [email protected]; [email protected] 2 Institute of Aviation Medicine, Air Force, Beijing, 100142, China; [email protected] 3 National Institutes for Food and Drug Control, Beijing, 100050, China. * Correspondence: H.C.: [email protected]; Tel.: +86-10-63037952; Z.H.: [email protected]; Tel.: +86- 10-67095597; † These authors contributed equally to this paper.

AMC The excitation and emission fluorescence spectra of AMC: We set the Em = 450 nm to obtain the excitation fluorescence spectra (left), we set the Ex= 350 nm to obtain the emission fluorescence spectra (right).

1117(EX) 1117(EM) 1400 9000 1300 1200 8000 1100 7000 1000 900 6000

800 5000 700 600 4000 500 3000 400 300 2000 200 1000 100 0 0

Resveratrol The excitation and emission fluorescence spectra of : We set the Em =400 nm to obtain the excitation fluorescence spectra (left), we set the Ex=304 nm to obtain the emission fluorescence spectra (right).

1117(EX) 1117(EM) 400 500

400 300

300 200

200 100 100

0 0

Daidzein The excitation and emission fluorescence spectra of : We set the Em = 490 nm to obtain the excitation fluorescence spectra (left), we set the Ex= 340 nm to obtain the emission fluorescence spectra (right).

1117(EX) 1117(EM) 1600 3000 1500 1400 1300 1200 1100 2000 1000 900 800 700 600 1000 500 400 300 200 100 0 0

Glycitein The excitation and emission fluorescence spectra of : We set the Em =490 nm to obtain the excitation fluorescence spectra (left), we set the Ex= 340 nm to obtain the emission fluorescence spectra (right). 1117(EM) 1117(EX) 3000 2000

2000

1000 1000

0 0

Formononetin The excitation and emission fluorescence spectra of : We set the Em =488 nm to obtain the excitation fluorescence spectra (left), we set the Ex= 338 nm to obtain the emission fluorescence spectra (right).

1117(EX) 1117(EM) 2000 700

600

500

1000 400

300

200

100 0 0

Calycosin The excitation and emission fluorescence spectra of Calycosin: We set the Em =478 nm to obtain the excitation fluorescence spectra (left), we set the Ex= 348 nm to obtain the emission fluorescence spectra (right).

1117(EX) 1117(EM) 1000 900 400 800 700 600 300 500 400 200 300 200 100 100 0 0