Keysight 81001XA Series Adapter (With Integral D-Shape) Data Sheet
Total Page:16
File Type:pdf, Size:1020Kb
Keysight 81001XA Series Adapter (with Integral D-Shape) Data Sheet This data sheet describes the Keysight 81001XA series Adapters (with integral D-Shape). These adapters allow you to connect fibers to an Optical Head using single-fiber or ribbon connectors, depending on the receptacle used. Fibers Supported Cleaning Instructions cleaning these adapters. If you are un- sure how sensitive your devices are to The Keysight Technologies, Inc. 81001XA Cleaning Materials cleaning, contact the manufacturer or series Adapters support single fiber con- your sales distributor. nectors for single-mode and multi-mode Swabs fibers with a maximum numerical aper- Use natural cotton swabs such as those Preferred Procedure: ture of 0.3. normally available from a supermarket or a chemist’s shop. Ensure that you use Use the following procedure on most Mechanical Lifetime natural cotton swabs; foam swabs often occasions: leave behind filmy deposits after cleaning. The plastic receptacle used in these Swabs should be used straight out of the 1. Clean the adapter by lightly rubbing adapters is subject to wear, and may packet, and never used twice. a new, dry cotton swab over the become damaged after a number of surface using a small circular insertions. Soft tissues movement. 2. Blow away any remaining lint with The following part replacement kits are Use multi-layered soft tissues made from compressed air. available: non-recycled cellulose, such as those normally available from a supermarket or Procedure for Stubborn 81001-41701 Repair Kit a chemist’s shop. Tissues should be used SC Recepticals for Keysight 81001KA straight out of the packet, and never used Dirt: connector adapter. twice. Use this procedure when there is greasy 81001-41702 Repair Kit Compressed air dirt on the adapter: E2000 recepticles for Keysight 81001PA Compressed air can be purchased from conector adapter. 1. Moisten a new cotton swab with any laboratory supplier. Make sure that isopropyl alcohol. your compressed air is free of dust, water Each kit consists of: 2. Clean the adapter by lightly rubbing and oil. Only use clean, dry air. – 10 x EA receptacles the cotton swab over the surface – 1 x EA wrench using a small circular movement. – 1 x EA instruction sheet Isopropyl alcohol 3. Take a new, dry soft tissue and remove the alcohol, dissolved This solvent is usually available from a sediment and dust, by rubbing pharmaceutical supplier or chemist’s Note gently over the surface using a small shop. Avoid using denatured alcohol con- circular movement. taining additives. Use alcohol intended for During re-assembly, take care that the 4. Blow away any remaining lint with medical purposes. receptacle is correctly orientated. compressed air. Caution Some adapters have an anti-reflective coating on the back to reduce back reflection. This coating is extremely sensitive to solvents and mechanical abrasion. Extra care is needed when Evolving Since 1939 For more information on Keysight Technologies’ products, applications or Our unique combination of hardware, software, services, and people can help you services, please contact your local Keysight reach your next breakthrough. We are unlocking the future of technology. office. The complete list is available at: From Hewlett-Packard to Agilent to Keysight. www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 myKeysight Korea 080 769 0800 www.keysight.com/find/mykeysight Malaysia 1 800 888 848 A personalized view into the information most relevant to you. Singapore 1 800 375 8100 Taiwan 0800 047 866 http://www.keysight.com/find/emt_product_registration Other AP Countries (65) 6375 8100 Register your products to get up-to-date product information and find warranty information. Europe & Middle East Austria 0800 001122 Keysight Services Belgium 0800 58580 www.keysight.com/find/service Finland 0800 523252 Keysight Services can help from acquisition to renewal across your France 0805 980333 instrument’s lifecycle. Our comprehensive service offerings—one- Germany 0800 6270999 stop calibration, repair, asset management, technology refresh, Ireland 1800 832700 Israel 1 809 343051 consulting, training and more—helps you improve product quality Italy 800 599100 and lower costs. Luxembourg +32 800 58580 Netherlands 0800 0233200 Keysight Assurance Plans Russia 8800 5009286 www.keysight.com/find/AssurancePlans Spain 800 000154 Up to ten years of protection and no budgetary surprises to ensure Sweden 0200 882255 your instruments are operating to specification, so you can rely on Switzerland 0800 805353 accurate measurements. Opt. 1 (DE) Opt. 2 (FR) Keysight Channel Partners Opt. 3 (IT) www.keysight.com/find/channelpartners United Kingdom 0800 0260637 Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, December 1, 2017 5988-4745EN www.keysight.com.