Operating Manual
Total Page:16
File Type:pdf, Size:1020Kb
99315161192-03.indb315161192-03.indb 1 22/26/2013/26/2013 111:02:001:02:00 AAMM CONTENTS SAFETY PRECAUTIONS ......................................En-1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS .............................En-2 AIR CIRCULATION .............................................En-10 NAME OF PARTS .................................................En-3 10°C HEAT OPERATION ....................................En-10 PREPARATION .....................................................En-5 SWING OPERATION ..........................................En-11 OPERATION ..........................................................En-6 COIL DRY OPERATION ......................................En-11 TIMER OPERATION .............................................En-8 CLEANING AND CARE .......................................En-12 SLEEP TIMER OPERATION .................................En-9 TROUBLESHOOTING ........................................En-14 MANUAL AUTO OPERATION ...............................En-9 OPERATING TIPS ...............................................En-16 SAFETY PRECAUTIONS ● Do not attempt to install this air conditioner by yourself. DANGER! ● This unit contains no user-serviceable parts. Always consult authorized service per- sonnel for repairs. ● When moving, consult authorized service personnel for disconnection and installation of the unit. ● Do not become excessively chilled by staying for lengthy periods in the direct cooling airfl ow. ● Do not insert fi ngers or objects into the outlet port or intake grilles. ● Do not start and stop air conditioner operation by disconnecting the power supply cord and so on. ● Take care not to damage the power supply cord. ● In the event of a malfunction (burning smell, etc.), immediately stop operation, discon- nect the power supply plug, and consult authorized service personnel. ● If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specifi ed cord are required. ● Provide occasional ventilation during use. CAUTION! ● Do not direct air fl ow at fi replaces or heating apparatus. ● Do not climb on, or place objects on, the air conditioner. ● Do not hang objects from the indoor unit. ● Do not set fl ower vases or water containers on top of air conditioners. ● Do not expose the air conditioner directly to water. ● Do not operate the air conditioner with wet hands. ● Do not pull power supply cord. ● Turn off power source when not using the unit for extended periods. ● Check the condition of the installation stand for damage. ● Do not place animals or plants in the direct path of the air fl ow. ● Do not drink the water drained from the air conditioner. ● Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works. ● Connection valves become hot during Heating; handle with care. ● Do not apply any heavy pressure to radiator fi ns. ● Operate only with air fi lters installed. ● Do not block or cover the intake grille and outlet port. ● Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units. ● Avoid installing the air conditioner near a fi replace or other heating apparatus. ● When installing the indoor and outdoor unit, take precautions to prevent access to infants. ● Do not use infl ammable gases near the air conditioner. En-1 99315161192-03.indb315161192-03.indb 1 22/26/2013/26/2013 111:02:101:02:10 AAMM FEATURES AND FUNCTIONS INVERTER OMNI-DIRECTIONAL AIR FLOW At the start of operation, a large power is used to bring the (SWING OPERATION) room quickly to the desired temperature. Afterwards, the unit Three-dimensional control over air direction swing is possible automatically switches to a low power setting for economic and through dual use of both an UP/DOWN air direction swing and comfortable operation. RIGHT/LEFT air direction swing. Since UP/DOWN air direction fl aps operate automatically according to the operating mode of the unit, it is possible to set air direction based on the operating COIL DRY OPERATION mode. The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium. REMOVABLE OPEN PANEL The indoor unit’s Open Panel can be removed for easy cleaning AUTO CHANGEOVER and maintenance. The operation mode (cooling, dry, heating) is switched automati- cally to maintain the set temperature, and the temperature is kept MILDEW-RESISTANT FILTER constant at all times. The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care. 10°C HEAT OPERATION The room temperature can be maintained at 10°C so as to pre- SUPER QUIET OPERATION vent the room temperature from falling too far. When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s airfl ow is PROGRAM TIMER reduced to produce quieter operation. The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence POLYPHENOL CATECHIN AIR CLEANING FILTER can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour The polyphenol catechin air cleaning fi lter uses static electricity period. to clean the air of fi ne particles and dust such as tobacco smoke and plant pollen that are too small to see. The fi lter contains catechin, which is highly effective against SLEEP TIMER various bacteria by suppressing the growth of the bacteria ad- sorbed by the fi lter. When the SLEEP button is pressed during Heating mode, Note that when the air cleaning fi lter is installed, the amount the air conditioner’s thermostat setting is gradually lowered of air produced decreases, causing a slight decrease in the air during the period of operation; during cooling mode, the conditioner’s performance. thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automati- cally turns off. NEGATIVE AIR IONS DEODORIZING FILTER It comprises pottery super micro particles, which can produce WIRELESS REMOTE CONTROL UNIT negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home. The Wireless Remote Control Unit allows convenient control of air conditioner operation. HORIZONTAL AIRFLOW: COOLING/ DOWNWARD AIRFLOW: HEATING For cooling, use horizontal airfl ow so the cool air does not blow directly on the occupants in the room. For heating, use down- ward airfl ow to send powerful, warm air to the fl oor and create a comfortable environment. En-2 99315161192-03.indb315161192-03.indb 2 22/26/2013/26/2013 111:02:111:02:11 AAMM NAME OF PARTS Fig. 1 1 E Ջࣱݻବ 8 MANUAL Fig. 2 AUTO 9 2 1 3 3 OPERATION 5 D TIMER 6 = A BC COIL DRY 7 Fig. 3 Fig. 5 4 8 Fig. 4 Fig. 6 N Z b [ MODE FAN ] a K Q Y R S e L c ^ M T d J U \ O X V P W Fig. 7 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current operation. En-3 99315161192-03.indb315161192-03.indb 3 22/26/2013/26/2013 111:02:111:02:11 AAMM Fig. 1 Indoor Unit Fig. 6 Remote Control Unit 1 Operating Control Panel (Fig. 2) J SLEEP button 2 MANUAL AUTO button K MASTER CONTROL button ● When kept on pressing the MANUAL AUTO L SET TEMP. button ( / ) button for more than 10 seconds, the forced M COIL DRY button cooling operation will start. N Signal Transmitter ● The forced cooling operation is used at the TIMER MODE button time of installation. O Only for authorized service personnel’s P TIMER SET ( / ) button use. Q FAN CONTROL button ● When the forced cooling operation starts by R START/STOP button any chance, press the START/STOP button S SET button (Vertical) to stop the operation. T SET button (Horizontal) U SWING button 3 Indicator (Fig. 3) V RESET button 4 Remote Control Signal Receiver W TEST RUN button 5 OPERATION Indicator Lamp (red) ● This button is used when installing the 6 TIMER Indicator Lamp (green) conditioner, and should not be used under ● If the TIMER indicator lamp fl ashes when the normal conditions, as it will cause the air timer is operating, it indicates that a fault has conditioner’s thermostat function to operate occurred with the timer setting (See Page 14 incorrectly. ● If this button is pressed during normal opera- Auto Restart). tion, the unit will switch to test operation mode, 7 COIL DRY Indicator Lamp (orange) and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin 8 Intake Grille (Fig. 4) to fl ash simultaneously. ● To stop the test operation mode, press the 9 Front Panel START/STOP button to stop the air condi- 0 Air Filter tioner. A Air Flow Direction Louver X CLOCK ADJUST button B Power Diffuser Y 10°C HEAT button C Right-Left Louver Remote Control Unit Display (Fig. 7) (behind Air Flow Direction Louver) Z [ Transmit Indicator D Drain Hose \ Clock Display E Air Cleaning Filter ] Operating Mode Display ` Timer Mode Display a Fan Speed Display Fig. 5 Outdoor Unit b Temperature SET Display F Intake Port c COIL DRY Display G Outlet Port d SLEEP Display H Pipe Unit e SWING Display I Drain port (bottom) En-4 99315161192-03.indb315161192-03.indb 4 22/26/2013/26/2013 111:02:111:02:11 AAMM PREPARATION Load Batteries (Size AAA R03/LR03 × 2) * CAUTION! ● Take care to prevent infants from acciden- Press and slide the battery compartment lid on the tally swallowing batteries. ● When not using the Remote Control Unit for 1 reverse side to open it. an extended period, remove the batteries to Slide in the direction of the arrow while pressing the mark. avoid possible leakage and damage to the * Batteries are not included with this product. unit. ● If leaking battery fl uid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and Insert batteries.