MGB Laparoscopy & Pelviscopy

Total Page:16

File Type:pdf, Size:1020Kb

MGB Laparoscopy & Pelviscopy Lapa_prod 1 01.11.2008 19:10 Uhr Seite 2 LAPAROSCOPY PELVISCOPY www.mgb-berlin.de CONTENT LAPAROSCOPY – PELVISCOPY I Telescopes Page 3-4 I Hand Instruments & Handles Page 5-7 I Shafts Page 8 I Dissecting- and Grasping Forceps, Ø 10 mm Page 9 I Scissors/Biopsy, Forceps, Ø 5 mm Page 10-11 I Dissecting- and Grasping Forceps, Ø 5 mm Page 11-18 I Insert with Shaft, Ø 3 mm Page 19 I Clip and Ligatur, Ø 10 mm, Ø 5 mm, Ø 3 mm Page 20 I Cannulas, Fascial Closure, Knot Pusher Page 21 I Retractors Page 22 I Magnetic Balls – Trocar Sleeves/Silicone-and Trumpet Valve Page 23 I Flap Valve – Trocar Sleeves Page 24-25 I Silicone Valve – Trocar Sleeves Page 26 I Flap Valve, Speculum Page 27 I Trocars Page 28 I Safety Trocars, Verres Needles Page 29 I Trocar Accessories Page 30 I Sealings Page 31 I Suction- and Irrigation Page 32-33 I HF-Monopolar Instruments Page 34 I Suction- and Irrigation, Accessories Page 35 I Bipolar Coagulation Instruments, Ø 5 mm, Ø 3 mm Page 36-40 I Bipolar Electrodes, Ø 5 mm, HF-Cables Page 41 I Insufflator ML-G Page 42-43 I Pump for Laparoscopy Page 44 I Morcellator & Accessories Page 45-47 2 Lapa_prod 1 01.11.2008 19:10 Uhr Seite 4 TELESCOPES LAPALUXHANDLE/KNIFES/HOOKS SHADOW-TELESCOPE II Product Order-No.Order-No. DescriptionDescription Ø 10 mm 429-62500 LAPALUX SHADOW-Telescope II I Direction of view 30° I Working length: 300 mm I Connector for Storz/Wolf/ACMI This Patent Telescope creates Shadow light guide cables The shade gives more information especially I Sign colour: red in the depth of field. Shadow Imaging The unique design, utilising two light bundles, generates a three dimensional perception of the operating field. Improved orientation may increase work rate and safety. High Resolution The high quality optical system guarantees ex- ceptional brightness and full illumination of the finest structures. Autoclavability As manufacturer we guarantee full autoclavability at 134 °C/273 °F. All LAPALUX SHADOW-telescopes are manufactured from stainless steel. Circle Ball Three-Dimensional Orientation The surgeon is guaranteed a better three- dimensional orientation of the surgical field through the visualization of shadow (natural representation of the pictures). Without Shade With Shade Product Order-No. Description Ø 10 mm 429-62000 OP-Telescope I Direction of view 0° I Working length: 270 mm I Connector for Storz/Wolf/ACMI I Sign colour: green I Working channel: Ø 6 mm 113 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 5 TELESCOPES TELESCOPES Products Order-No. Description Ø 10 mm 0° 429-60050 LAPALUX-Telescope 0° HD I Direction of view 0° I Working length: 300 mm I Connector for Storz/Wolf/ACMI I Sign colour: green I 429-60050 BA Working length: 510 mm NEW 30° 429-61050 LAPALUX-Telescope 30° HD I Direction of view 30° I Working length: 300 mm I Connector for Storz/Wolf/ACMI I Sign colour: red 429-61050 BA I Working length: 510 mm Ø 7 mm 30° 429- 66000 LAPALUX-Telescope 30° I Direction of view 30° I Working length: 310 mm I Connector for Storz/Wolf/ACMI I Sign colour: red Ø 5 mm 0° 429-67050 LAPALUX-Telescope 0° HD I Direction of view 0° I Working length: 330 mm I Connector for Storz/Wolf/ACMI I Sign colour: green NEW 30° 429-68050 LAPALUX-Telescope 30° HD I Direction of view 30° I Working length: 330 mm I Connector for Storz/Wolf/ACMI I Sign colour: red Ø 2.9 mm 429- 63000 LAPALUX-Telescope 0° 0° I Direction of view 0° I Working length: 300 mm I Connector for Storz/Wolf/ACMI I Sign colour: green 30° 429-64000 LAPALUX-Telescope 30° I Direction of view 30° I Working length: 300 mm I Connector for Storz/Wolf/ACMI I Sign colour: red 4 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 6 HAND INSTRUMENTS HAND INSTRUMENTS FOR MIS The New Hand Instrument consist of: I Handle I Shaft I Insert 1 Advantages 5 I1 Ergonomic developed handle for permanent exhaustless working I2 Ergonomic warped handle-side 2 I3 Ergonomic optimised grap- and side-angle I4 Soft and trapeze similar rounded grap radius avoid bruises I5 Wedge-shaped finger-hollow adjusting wheel for optimal finger-contact with big or small hands I Oval, rejuvenated fingerrings support big as well as small hands I Light constructed handle I Compact and robust instrument I Ratched design for optimal processing 3 I Autoclaveable and disassemble I Long-lasting materials I Exact and long-lasting 4 Instrument-Insert Distal-Interface I Wide range of instruments I In this place, the insert can be and cost-savings exchange in screwed into the shaft. case of use up by exchange- able inserts for Ø 3 mm, Ø 5 mm and Ø 10 mm shafts. Shafts Proximal-Interface Handles Ø 3 mm Instruments I For this hand instruments- I This interface is same by all I There are different handles to Insert and insulated shaft are always system, isolated and metal handles and shafts; because our system available and also connected together. shafts are available in diame- of this, all inserts are able to with different kind of ratches. ter of Ø 5 mm and Ø 10 mm. be connected with the whole Another advantage is that we handle-spectrum through have also shaft with Ø 10 mm shaft knob. outer diameter which is made for the Ø 5 mm inserts. Oblique HF-Connector Therefore, you will get a very I robust instrument. For monopolar coagulation 5 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 7 MONTAGE INTERFACE AND CONTROL 1. Distal Interface I The instrument-inserts are pushed right down into the shafts and screwed to the end. Important: close the insert-mouth completely, because of impairment cutting! I The distal interface is different between Ø 5 mm and Ø 10 mm instruments. 2. Proximal Interface I The insert should be closed now and the handle should be opened at the maximum. From now on, put the ball into the gap from an oblique position. Close the handle and screw the shaft knob. 3. Function Control I Now, the instrument is completely assembled. Concluding, a function control is to be hold. It will be tested if a relaxed connection between handle and insert exists. 6 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 8 INSTRUMENTS HANDLES Products Order-No. Description 429-77015 GRP-Laparoscopic Handle Polymer I With HF-connection I Fibre-reinforced 429-77030 GRP-Laparoscopic Handle Polymer with Ratchet I With HF-connection I Fibre-reinforced 429-75003 Metal Handle 429-75002 Metal Handle with Ratchet 7 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 9 INSTRUMENTS SHAFTS Products Order-No. Description 429-75035 Metal Shaft with Shaft Knob I Working length: 330 mm I Ø 5 mm 429-75031 Metal Shaft with Shaft Knob I Working length: 330 mm I Ø 10 mm Insulated Shaft with Shaft Knob Ø 5 mm 429-75065 I Working length: 330 mm 429-75065/22 I Working length: 220 mm 429-75065/44 I Working length: 440 mm Insulated Shaft with Shaft Knob Attention Ø 10 -5 mm Shaft outer-diameter Ø 10 mm: 429-75062 I Working length: 330 mm for Ø 5 mm inserts Ø 10 mm 429-75061 I Working length: 330 mm 429-75061/44 I Working length: 440 mm Shaft Knobs: I For Ø 10 mm inserts separate delivery, Order-No.: 429-75081 I For Ø 3-/Ø 5 mm inserts separate delivery, Order-No.: 429-75085 108 Lapa_prod 1 01.11.2008 19:11 Uhr Seite 10 INSERTS DISSECTING- AND GRASPING FORCEPS Inserts Order-No. Description Ø 10 mm 429-75263 Spoon Grasping Forceps I Single action Allis 429-75215 Grasping Forceps I Double action 429-75281 (330 mm) Claw Forceps 429-75281/44 (440 mm) I 2 to 3 teeth I Sharp I Double action 429-75165 Dissecting Forceps 90° Mixter I Right-angled 90° I Double action Babcock 429-75191 Grasping Forceps I Double action 429-75164 Grasping Forceps Maryland I Slight curved I Double action 429-75282 Tenaculum 429-75282/44 9 Lapa_prod 2 01.11.2008 19:25 Uhr Seite 1 INSERTS SCISSORS/BIOPSY Inserts Order-No. Description Ø 5 mm 429-75301 Micro Scissors Straight ISingle action 429-75154 Endo Scissors I Curved 429-75111 Peritoreal Scissors I Straight I Serrated jaw I Single action 429-75261 (330 mm) Hook Scissors 429-75261/22 (220 mm) I Hardened 429-75261/44 (440 mm) I Single action Metzenbaum 429-75152 Scissors I Straight I Double action 10 Lapa_prod 2 01.11.2008 19:25 Uhr Seite 2 INSERTS SCISSORS/BIOPSY FORCEPS Inserts Order-No. Description Ø 5 mm Metzenbaum 429-75153 (330 mm) Scissors 429-75153/22 (220 mm) I Curved 429-75153/44 (440 mm) I Double action 429-75158 Preparation Scissors I “Special-cut” I Curved I Double action Metzenbaum 429-75155 Scissors Heavy I Straight I Heavy blades 429-75273 Biopsy Forceps Blakesly I Single action 429-75271 Biopsy Forceps I Single action 11 Lapa_prod 2 01.11.2008 19:25 Uhr Seite 3 INSERTS DISSECTING- AND GRASPING FORCEPS Inserts Order-No. Description Ø 5 mm 429-75274 Biopsy Forceps I With pin I Single action 429-75275 Biopsy Forceps ISpoon jaw IDouble action 429-75272 Biopsy Forceps ISpoon jaw with pin IDouble action 429-75238 Alligator Grasping- and Biopsy Forceps IDouble action 429-75121 Dissecting Forceps I Slim I Single action 124 Lapa_prod 2 01.11.2008 19:25 Uhr Seite 4 INSERTS DISSECTING- AND GRASPING FORCEPS Inserts Order-No.
Recommended publications
  • Single Port Laparoscopic Hysterectomy Through a 12Mm Incision Created by a Bladeless Trocar: a Novel Technique
    Single Port Laparoscopic Hysterectomy through a 12mm incision created by a Bladeless Trocar: A Novel Technique Greg J. Marchand, M.D., Katelyn M. Sainz MS1 From the National Foundation for Minimally Invasive Surgery (minvase.org), and Research and Development division of Marchand OBGYN PLLC Precis: Single Port Hysterectomy can be performed safely through a 12mm bladeless incision via this novel technique. Decreasing port size is continually pushing the limits of minimally invasive surgery for enhanced patient outcomes. Corresponding author: Greg J. Marchand M.D., Marchand OBGYN Research and Development, 1520 S. Dobson #218, Mesa, AZ 85202, Tel: 480-628-0566, Fax: 480-999-0801 ABSTRACT Study Objective: The aim of this study is to report the technique used by one surgeon performing a laparoscopic hysterectomy performed through a single 12mm bladeless incision. With the exception of pure vaginal hysterectomy we believe this technique is the least invasive technique published thus far to date where the hysterectomy is performed entirely abdominally. Design: Retrospective Analysis of Charts and Technique Setting: One private Hospital in the Southwest US Patients: 6 patients receiving single port hysterectomy between 2013 and 2014 Intervention: Single Port Laparoscopic Hysterectomy was performed with our ultra-minimally invasive technique, using a Covidien(C) 12mm bladeless laparoscopic trocar followed by an Olympus(C) TriPort device and Olypus(C) articulating 5mm laparoscope without in any way stretching or extending the 12mm port. Other novel aspects of our technique include placement of the single port at the bottom of the umbilicus regardless of patient BMI, the usage of intra-abdominal marcaine to help with postoperative pain and vaginal repair of colpotomy.
    [Show full text]
  • Entry Techniques in Gynecologic Laparoscopy—A Review
    Gynecol Surg (2012) 9:139–146 DOI 10.1007/s10397-011-0710-8 REVIEW ARTICLE Entry techniques in gynecologic laparoscopy—a review Johannes Ott & Agnes Jaeger-Lansky & Gunda Poschalko & Regina Promberger & Eleen Rothschedl & René Wenzl Received: 9 June 2011 /Accepted: 19 October 2011 /Published online: 13 November 2011 # Springer-Verlag 2011 Abstract Laparoscopy is one of the most common surgical underpowered in order to assess the risk for rare but life- procedures in gynecologic medicine. Major complications threatening complications. In conclusion, there is no solid associated with gynecologic laparoscopy are relatively rare, evidence proving the superiority of any method of with up to 50% related to laparoscopic entry. Several entry laparoscopic entry. techniques have been developed, all of which aim to provide a safe and easy entry to the abdominal cavity. In Keywords Laparoscopy. Entry techniques . Gynecology. this article, we aim to review the available evidence on Complications . Veress needle . Hasson technique . Direct laparoscopic entry techniques in gynecologic surgery. We trocar entry found no evidence that the Hasson (open) technique is superior to the Veress needle entry, the preferred method of most gynecologists all over the world. When entering the Background abdomen using the Veress needle, an intraperitoneal pressure <10 mmHg is a reliable predictor of correct Laparoscopy is one of the most common surgical intraperitoneal placement. Entry at Palmer’s point (left procedures in gynecologic medicine and has become upper quadrant laparoscopy) is recommended for patients the method of choice over the last few decades for with suspected or known periumbilical adhesions, or a treating benign diseases that require surgery [1, 2].
    [Show full text]
  • Comparison Between Different Entry Techniques in Performing Pneumoperitoneum In10.5005/Jp-Journals-10033-1257 Laparoscopic Gynecological Surgery REVIEW ARTICLE
    WJOLS Comparison between Different Entry Techniques in Performing Pneumoperitoneum in10.5005/jp-journals-10033-1257 Laparoscopic Gynecological Surgery REVIEW ARTICLE Comparison between Different Entry Techniques in Performing Pneumoperitoneum in Laparoscopic Gynecological Surgery Mandavi Rai ABSTRACT safety of one technique over another. However, the included studies are small and cannot be used to confirm safety of any Background: The main challenge facing the laparoscopic particular technique. No single technique or instrument has surgery is the primary abdominal access, as it is usually a blind been proved to eliminate laparoscopic entry-associated injury. procedure associated with vascular and visceral injuries. Lapa- Proper evaluation of the patient, supported by good surgical roscopy is a very common procedure in gynecology. Complica- skills and reasonably good knowledge of the technology of the tions associated with laparoscopy are often related to entry. instruments remain to be the cornerstone for safe access and The life-threatening complications include injury to the bowel, success in minimal access surgery. bladder, major abdominal vessels, and anterior abdominal- wall vessel. Other less serious complications can also occur, Keywords: Complications, Laparoscopy, Pnumoperitoneum, such as postoperative infection, subcutaneous emphysema Trocar. and extraperitoneal insufflation. There is no clear consensus as to the optimal method of entry into the peritoneal cavity. It How to cite this article: Rai M. Comparison between Dif- has been proved from studies that 50% of laparoscopic major ferent Entry Techniques in Performing Pneumoperitoneum complications occur prior to the commencement of the surgery. in Laparos copic Gynecological Surgery. World J Lap Surg The surgeon must have adequate training and experience in 2015;8(3):101-106.
    [Show full text]
  • Use of the Veress Needle to Obtain Pneumoperitoneum Prior to Laparoscopy
    Use of the Veress needle to obtain pneumoperitoneum prior to laparoscopy Consensus statement of the Royal Australian & New Zealand College of Obstetricians & Gynaecologists This statement has been developed by the Women’s (RANZCOG) and the Australasian Gynaecological Health Committee. It has been reviewed by the Endoscopy and Surgery Society (AGES). Endoscopic Surgery Advisory Committee (RANZCOG/AGES) and approved by the Objectives: To provide advice on the use of the RANZCOG Board and Council. Veress needle to obtain pneumoperitoneum prior to laparoscopy. A list of Women’s Health Committee and Endoscopic Surgery Advisory Committee Target audience: Health professionals providing (RANZCOG/AGES) Members can be found in gynaecological care, and patients. Appendix A. Values: The evidence was reviewed by the Disclosure statements have been received from all Endoscopic Surgery Advisory Committee members of this committee. (RANZCOG/AGES), and applied to local factors relating to Australia and New Zealand. Disclaimer This information is intended to provide Background: This statement was first developed by general advice to practitioners. This information Women’s Health Committee in April 1990 and most should not be relied on as a substitute for proper recently reviewed by the Endoscopic Surgery assessment with respect to the particular Committee (RANZCOG/AGES) in July 2017. circumstances of each case and the needs of any patient. This document reflects emerging clinical Funding: The development and review of this and scientific advances as of the date issued and is statement was funded by RANZCOG. subject to change. The document has been prepared having regard to general circumstances. First endorsed by RANZCOG: April 1990 Current: July 2017 Review due: July 2020 1 Table of contents Table of contents ............................................................................................................................
    [Show full text]
  • AUA BLUS Handbook of Laparoscopic and Robotic Fundamentals
    AUA BLUS Handbook of Laparoscopic and Robotic Fundamentals Sean Collins, Daniel S. Lehman, Elspeth M. McDougall, Ralph V. Clayman, and Jaime Landman ©American Urological Association Education & Research, Inc. Table of Contents 1. Introduction 2. Patient selection a. Indication b. contradindications c. special considerations 3. Physiologic effects of pneumoperitoneum a. Renal surgery transperitoneal b. Renal surgery retroperitoneal c. Hand-assisted laparoscopic nephrectomy d. Prostatectomy 4. Getting Started 5. Patient positioning a. Renal surgery transperitoneal b. Renal surgery retroperitoneal c. Hand-assisted laparoscopic nephrectomy d. Prostatectomy 6. Strategic placement of surgical team and operating room (OR) equipment 7. Access a. Primary access b. Renal surgery transperitoneal trocar placement c. Renal surgery retroperitoneal trocar placement d. Secondary access e. Retroperitoneal primary and secondary access f. Hand-assisted laparoscopic nephrectomy trocar placement g. Prostatectomy trocar placement 8. Instrumentation a. Trocars i. Cutting ii. Dilating iii. Radially dilating b. Bipolar cautery c. Monopolar cautery d. Ultrasonic instrumentation e. Vessel sealing devices i. LigaSure ii. Enseal f. Staplers g. Vascular clamps h. Suture anchors i. Titanium clips j. Locking clips q. Retractors r. Hemostatic agents s. Hand Assisted devices 2 9. Technique for Transperitoneal Laparoscopic Nephrectomy 10. Complications of laparoscopic surgery 3 Chapter 1. Introduction The American Urological Association (AUA) has prepared this handbook for all those new to laparoscopy. Rather than being a detailed surgical atlas, this is a handbook designed to introduce the fundamental principles of laparoscopy including: indications and contraindications for laparoscopy, the physiologic effects of pneumoperitoneum, patient positioning; abdominal access and trocar placement; strategic placement of the operating room (OR) team and equipment, overview of laparoscopic instrumentation, and complications unique to laparoscopic surgery.
    [Show full text]
  • Intraperitoneal Access by Closed Method (Veress Needle) Versus Open (Hasson’S) Method in Laparoscopic Surgery to Create Pneumoperitoneum
    International Surgery Journal Chotai NR et al. Int Surg J. 2017 Aug;4(8):2786-2790 http://www.ijsurgery.com pISSN 2349-3305 | eISSN 2349-2902 DOI: http://dx.doi.org/10.18203/2349-2902.isj20173419 Original Research Article Intraperitoneal access by closed method (veress needle) versus open (Hasson’s) method in laparoscopic surgery to create pneumoperitoneum Neet R. Chotai*, Dilip B. Choksi, Sushil Damor, Amul Bhedi Department of General Surgery, Government Medical College Baroda, Vadodara, India Received: 18 May 2017 Accepted: 17 June 2017 *Correspondence: Dr. Neet R. Chotai, E-mail: [email protected] Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT Background: Access into the abdomen is the one challenge of laparoscopy that is particular to the insertion of surgical instruments through small incisions. In the last three decades, rapid advances in laparoscopic surgery have made it an invaluable part of general surgery, but there remains no clear consensus as an on optimal method of entry into the peritoneal cavity. The objective of this study was to study the comparison and efficacy between closed (veress needle)and open method (Hasson’s) of intraperitoneal access to create pneumoperitoneum in laparoscopic surgeries. Methods: All patients >18 year undergoing laparoscopic procedure at Sir Sayajirao Gaekwad Hospital attached to Medical College Baroda from November 2015 to November 2016, and include 160 patients.
    [Show full text]
  • Development of an Intraperitoneal Catheter Placement Device for Use on the Battlefield
    University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Mechanical (and Materials) Engineering -- Mechanical & Materials Engineering, Dissertations, Theses, and Student Research Department of 5-2021 Development of an Intraperitoneal Catheter Placement Device for Use on the Battlefield Riley Reynolds University of Nebraska-Lincoln, [email protected] Follow this and additional works at: https://digitalcommons.unl.edu/mechengdiss Part of the Biomedical Devices and Instrumentation Commons, Materials Science and Engineering Commons, and the Mechanical Engineering Commons Reynolds, Riley, "Development of an Intraperitoneal Catheter Placement Device for Use on the Battlefield" (2021). Mechanical (and Materials) Engineering -- Dissertations, Theses, and Student Research. 164. https://digitalcommons.unl.edu/mechengdiss/164 This Article is brought to you for free and open access by the Mechanical & Materials Engineering, Department of at DigitalCommons@University of Nebraska - Lincoln. It has been accepted for inclusion in Mechanical (and Materials) Engineering -- Dissertations, Theses, and Student Research by an authorized administrator of DigitalCommons@University of Nebraska - Lincoln. DEVELOPMENT OF AN INTRAPERITONEAL CATHETER PLACEMENT DEVICE FOR USE ON THE BATTLEFIELD By Riley Reynolds A THESIS Presented to the Faculty of The Graduate College at the University of Nebraska In Partial Fulfillment of Requirements For the Degree of Master of Science Major: Mechanical Engineering and Applied Mechanics Under the Supervision of Professor Benjamin S. Terry Lincoln, Nebraska May 2021 DEVELOPMENT OF AN INTRAPERITONEAL CATHETER PLACEMENT DEVICE FOR USE ON THE BATTLEFIELD Riley Reynolds, M.S. University of Nebraska, 2021 Adviser: Benjamin Terry The objective of this project was to simplify peritoneal cavity access so an Airforce field medic can safely infuse oxygen microbubbles (OMBs) into the intraperitoneal space for the emergency treatment of hypoxia due to lung damage.
    [Show full text]
  • Trusted Fluid Management
    Trusted Fluid Management Product Catalogue Table of contents Medline’s fluid management solution Suction systems 4 MED-SOFT 4 MED-RIGID 8 As a global provider of comprehensive fluid management Suction system accessories 10 solutions, Medline is fulfilling the needs of facilities by Reusable accessories 11 offering a wide range of high-quality and cost-effective Suction tubing 12 products that fully meet clinical requirements. Suction connecting tubing 12 Choosing a suction system is not only an important step in Suction tubing rolls 14 providing the best and most efficient care possible, it is also Accessories 15 fundamental in ensuring the safety of patients and healthcare Yankauers and suction cannulas 16 personnel. Rigid yankauers 16 Suction cannulas 18 Medline’s top fluid management suction systems are the MED-SOFT and MED-RIGID canisters and liners. Both aim to Gynaecology portfolio 19 collect liquids, bodily fluids and aspiration waste during all Uterine aspiration 19 types of procedures. Gynaecological suction tubing 20 Accessories 21 Along with suction accessories and complementary products Floor safety 23 with multiple applications, the possibilities are endless for tailoring your fluid management solution exactly to your Floor absorbency 23 needs. Laparoscopy portfolio 24 Laparoscopy essentials 24 MED-SOFT MED-SOFT Canisters and Liners Medline’s MED-SOFT provides a specially designed suction system for safe and easy handling of bodily fluids, liquids and aspiration waste. This closed suction system is made of single- patient-use
    [Show full text]
  • Veterinary Instrumentation
    VETERINARY INSTRUMENTATION EQUINE & LARGE ANIMAL Broadfield Road, Sheffield, UK S8 0XL Tel:0845 130 9596 Fax: 0845 130 8687 E-mail: [email protected] Website: www.vetinst.com Overseas Customers use:Tel:+44 114 258 8530 Fax: +44 114 255 4061 Welcome Dear Colleague, Welcome to our Equine and Large Animal catalogue. Our last equine catalogue was published in 2004 and we have moved on in many ways. This catalogue now has over twice the number of products including many which are unique or exclusive which I hope will be of interest. You will find new products in all chapters, but the surgery and orthopaedics chapters have the greatest number of additions. One of the main areas of change has been the increase in minimally invasive surgery and we are pleased to have been appointed the exclusive distributor for Scil in the UK. You may not be familiar with the name but you will recognise their products which include the Dr Fritz range of both Arthroscopy and Laparoscopy. Another company which is driving developments in both Arthroscopy and Laparoscopy is Arthrex Vet Systems. Arthrex are now offering a free loan of an Arthroscopy Infusion pump for an annual purchase commitment of patient infusion sets. Arthrex have also recently launched their Autologous Blood John Lapish BSc., BVetMed., MRCVS. Products range with a similar arrangement for a centrifuge and rotor. Chairman Brand new technologies also shown in this catalogue for the first time include Osteoallograft from Veterinary Transplant Services which is available in the UK In 2003 John was awarded the BSAVA Simon for the first time.
    [Show full text]
  • Comparative Study of Veress Needle and Visiport in Creating Pneumoperitoneum in Laparoscopic Surgery
    COMPARATIVE STUDY OF VERESS NEEDLE AND VISIPORT IN CREATING PNEUMOPERITONEUM IN LAPAROSCOPIC SURGERY Thesis submitted by: Dr. Sheela Prince Roll No.: TGOU (N) 009/M.MAS/2014D To the Global Open University Department of Minimal Access Surgery World Laparoscopy Hospital Center Global Open University of Nagaland In partial fulfillment for the Award of Masters Degree in Minimal Access Surgery January 2018 COMPARATIVE STUDY OF VERESS NEEDLE AND VISIPORT IN CREATING PNEUMOPERITONEUM IN LAPAROSCOPIC SURGERY Thesis submitted to the Global Open University in partial fulfillment of the rules and regulations for the Masters in Minimal Access Surgery Degree Examination By: Dr. Sheela Prince Department of Minimal Access Surgery World Laparoscopy Center Global Open University, Nagaland. CERTIFICATE This is to certify that the research name Comparative Study of Veress Needle and Visiport in creating pneumoperitoneum in laparoscopic surgery done by Dr. Sheela Prince under my personal supervision and guidance. I am satisfied with the work done by her, which is presented as dissertation for Masters Degree in Minimal Access Surgery Examination certified that the study is original embodying bonafied cases. Dr. Packirisamy Kannan Head of General Surgery Department Hatta Hospital Consultant, General Surgery Department Rashid Hospital Place: Date: DECLARATION This is a consolidated report on comparative study of Veress Needle and Visiport in creating pneumoperitoneum in Laparoscopic Surgery based on the cases treated in Rashid Hospital from the period of 01.01.2015 to 31.12.2015. This is submitted to the Global Open University in partial fulfillment of rules and regulations for the Masters in Minimal Access Surgery Examination. This thesis has not been submitted for any other degrees and have no objections for this thesis to be copied in part or whole or used for research purpose.
    [Show full text]
  • Risks of Laparoscopic Surgery
    Obstetrics & Gynecology International Journal Mini Review Open Access Risks of laparoscopic surgery Abstract Volume 3 Issue 4 - 2015 Laparoscopic surgery, like any operative intervention carries risks. In gynaecology in particular the patients are largely young fit women and significant complications, although Hasib Ahmed Canterbury Christ Church University, UK rare, have devastating consequences. We review in short the issues to consider with regards to minimising risks and obtaining informed consent. Correspondence: Hasib Ahmed, Institute of Medical Sciences, Keywords: women, laparoscopy, risks, surgery, trocar, injury Canterbury Christ Church University, 100 Borstal Road Rochester, Kent ME1 3BD United Kingdom, Tel 441634847769, Email Received: November 22, 2015 | Published: December 23, 2015 Introduction likely to proceed to litigation.13 The Physician Insurers Association of America examined 535 laparoscopic cases of which 163 claims were Early reference to a form of endoscopy dates back to the time of settled out of cour.14 An average settlement figure of over $212000 Hippocrates. It wasn’t, however, until the turn of the last Century that is quoted. A quarter of claims were related to primary or secondary the first experimental laparoscopy was performed. Georg Kelling used trocar insertion and 8.2% related to Veress needle injuries. Cautery a cystoscope to examine the abdomen of a dog after first insufflating it equipment and instruments such as scissors or scalpels accounted 1 with air. Even though the rudiments of the technique are more than one for only 5.4% of claims. Claims for gynaecological cases with the hundred years old, operative laparoscopy did not gain acceptance until Medical Defence Union have increased from 1 in 1000 in 1978 to 24 the late 1980’s.
    [Show full text]
  • Enhanced Surgical Skills Training Program for Family Physicians
    ENHANCED SURGICAL SKILLS TRAINING PROGRAM FOR FAMILY PHYSICIANS AN INTEGRATED MODULAR CURRICULUM Draft 2 as of January 20, 2014 2 January 20, 2014 | Enhanced Skills Surgery Curriculum - Draft TABLE OF CONTENTS INTRODUCTION 5 Preamble 5 Demographics 6 The Training Programs 7 Curriculum 8 Evaluation 9 Certification 11 References 12 APPENDICES A. Committee Membership 15 1. National Working Group on Enhanced Surgical Skills 15 2. Curriculum and Evaluation Committee 16 B. The Curriculum Modules 17 Basic Operative Management 19 1. Surgery 101 – antisepsis, hemostasis, incisions, stabilization, wound healing, 20 suturing and instruments, physiologic reaction to surgery, nutrition 2. Patient Selection and Preparation – surgical and anaesthetic 24 3. Surgical Decision Making – crew resource management/OR decision-making, 26 patient transfer decision and management, triage Management of Abdominal Presentation in the Non-Pregnant Patient 29 in Rural and Remote 4. Abdominal Wall Mass or Pain 30 5. Acute Right Lower Quadrant Pain – 32 appendicitis/appendectomy, adnexal/ovarian disease 6. GI Bleeding Upper and Lower 35 7. GI Screening & Surveillance – Upper GI, Lower GI 38 8. Perianal Presentations – hemorrhoids, infections 40 Management of Pregnancy in Rural and Remote 43 9. Complications of Labour & Delivery – operative vaginal delivery, C-section, 44 obstetrical trauma, uterine inversion, PPH, retained placenta; ALARM, NRP 10. First Trimester Pain and Bleeding – D&C, ectopic 47 Enhanced Skills Surgery Curriculum - Draft | January 20, 2014 3 Management of Non-Abdominal Presentations in Rural and Remote 51 11. Integumentary Lesions – skin, nails, subcutaneous lesions, ganglia, lipoma, 52 flaps, skin grafting 12. Fertility – vasectomy, tubal ligation, essure 53 13. GenitoUrinary Disease – acute testicular/scrotal disease, phimosis, circumcision, 56 hydrocele, urethral dilation 14.
    [Show full text]