Lesson 4: What Are the Units for Measuring Radon?
Total Page:16
File Type:pdf, Size:1020Kb
Measuring radon in residential properties What are the units for measuring radon? Lesson 4: What are the units for Notes measuring radon? Lesson overview This lesson introduces the units used to measure radon. Lesson objectives By the end of this lesson, the learners will be able to: • Identify three units used to measure radon and radon decay products in homes • List the EPA action levels for the three units used to measure radon and radon decay products in homes • Identify four factors that may affect measurements of radon decay products In this lesson, we are going to talk about the units that we use to measure radon. See slide 41. First, we’ll talk briefly about measuring radioactivity, or the number of radioactive decays over a given period of time. The important unit here is the picocurie, which equals • 0.037 decays per second • 1 decay every 27 seconds • 2.22 decays per minute See slide 42. When we measure radon gas, we consider the activity (the number of decays per minute) for a given volume of air (one liter). A liter is a little larger than a quart. So 1 pCi/L = 2.22 decays/minute/liter Remember the EPA action level for radon: 4 pCi/L. What does the EPA action level represent in terms of radioactive decays per time and volume? Correct answer: EPA action level = 4 pCi/L = 8.88 decays/minute/liter. Lesson 41 Measuring radon in residential properties What are the units for measuring radon? See slide 43. Notes Assume that a client spent 10 hours/day (perhaps sleeping for 8 hours and watching TV for 2 hours) in a room that had a radon level of 4 pCi/L. How many decays/liter would the client be exposed to each day? Answer: 5,328 days/day/liter. See slide 44. This slide illustrates the average exposure to radiation in the United States. As you can see, radon accounts for more exposure than any other single source. See slide 45. Another method of measuring radioactivity, often used outside the United States, uses units called becquerels. A becquerel equals 1 decay per second. Since a picocurie equals one decay every 27 seconds, one becquerel also equals 27 picocuries. And since one picocurie equals 0.037 decays/second, one picocurie also equals 0.037 becquerels. Like picocuries, becquerels measure activity. To measure radon gas, we use activity (becquerels) for a given volume of air (in this case, a cubic meter, not a liter). A cubic meter equals 1000 liters. When we do the math, we find: One picocurie per liter of radon equals 37 becquerels per cubic meter. Consider. Again, let’s consider the EPA action level for radon. How would you represent it in becquerels? Correct answer: EPA action level = 4 x 37 Bq/m 3 = 148 Bq/ m 3 See slide 46. So far, we’ve been talking about how to measure radon gas alone. However, earlier we explained that radon decay products (RDPs) Lesson 42 Measuring radon in residential properties What are the units for measuring radon? also contribute to health risks. In fact, the term radon sometimes Notes refers broadly to both radon and its decay products. In particular, we measure the alpha radiation emitted by the four shortlived radon decay products: • Polonium218 • Lead214 • Bismuth214 • Polonium214 See slide 47. We measure the radiation from radon decay products differently. For RDPs, we generally use a unit called the working level (WL). There are several ways to define the working level. • One WL is the concentration of RDPs produced from one liter of air that contains 100 pCi/L of radon. • One WL is the amount of shortlived radon progeny that exists at a single moment if a container is kept at a constant 100 pCi/L. The equivalent of the EPA action level of 4 pCi/L is 0.02 WL. See slide 48. In summary, we can express the EPA action level for radon in three forms: • 4 pCi/L • 148 Bq/m 3 • 0.02 WL As a practical matter, the form we use most often is 4 pCi/L. See slide 49. Consider. Are there any questions so far? See slide 410. Several factors can raise or lower the concentration of radon and RDPs that can be measured. • Some radon gas and RDPs naturally escape as air flows out of the home. Lesson 43 Measuring radon in residential properties What are the units for measuring radon? As we noted earlier, unlike radon gas, radon decay products are Notes • Solid particles • Electrically charged • Chemically reactive These characteristics determine how RDPs behave and how they are measured. • Some RDPs attach to (or plate out on) solid objects, such as walls, floors, ceilings, and furniture. • Plating out lowers their concentration in the air. • Platedout RDPs cannot be measured. o Only the RDPs that remain in the air can be measured. o Therefore, factors that affect plating out also affect the measurement of RDPs. See slide 411. Among the factors that we need to consider are • Air circulation • Ventilation • Air filters • Particles suspended in the air. See slide 412. Let’s first consider air circulation (that is, moving around the air that is already within a room). For example, fans increase normal air circulation. Consider. How do you think air circulation would affect the concentration of RDPs? Correct answer: • Circulation, or moving air, may increase plating out, as RDP particles blow toward solid objects and attach to them. • When plating out increases, the concentration of RDPs in the air decreases. See slide 413. Lesson 44 Measuring radon in residential properties What are the units for measuring radon? We said that circulation refers to moving around air that is already Notes in the space. In contrast, ventilation refers to a supply of fresh air. Open windows and doors increase ventilation. Consider. What effect do you think ventilation would have on the concentration of RDPs? Correct answer: Again, ventilation is likely to lower the concentration of RDPs. It may also reduce the concentration of radon, as the gas escapes from the home. See slide 414. Another factor that affects the concentration of RDPs is an air filter—in a furnace, for example. Consider. How do you think an air filter would affect the concentration of RDPs? Correct answer: A filter might remove some RDPs, which are charged particles that are chemically active. A filter would not remove radon gas itself, which has no electrical charge and is not chemically active. Thus, a filter would lower the concentration of RDPs. See slide 415. Consider. What effect do you think particles suspended in the air (such as dust, smoke, and aerosols) might have? Correct answer: When there are particles in the air, RDPs are more likely to attach to these particles. Thus the RDP concentration in the air is likely to decrease. Lesson 45 Measuring radon in residential properties What are the units for measuring radon? See slide 416. Notes As you see, air circulation, ventilation, air filters, and particles in the air can all affect radon measurement. We’ll see the importance of these factors again when we discuss the conditions that are needed to measure radon during shortterm tests. See slide 417. Earlier, when we described radon, we said that over time, radon decays into various shortlived radon decay products. In a closed system, like a closed home, the concentration of RDPs in the house increases until a situation called secular equilibrium is reached. (In this term, secular means eventual.) Secular equilibrium occurs when the radon decay products have the same level of radioactivity as the radon itself. In other words, the rate of decay of each shortlived RDP will equal the rate of decay of the radon itself. Achieving secular equilibrium takes about 3 to 4 hours. You will need to measure radon in a home after it has reached secular equilibrium. When we talk about the necessary conditions for short term testing, you’ll see that these conditions reflect the time needed to achieve secular equilibrium. See slide 418. This slide is intended as a little light relief and as a reminder of why the information in this section is important. See handout 41. Handout 41 summarizes this section on the units we use to measure radon and its decay products. Summary. See slide 422. Let’s review the units for measuring radon and radon decay products: • Picocuries/liter • Becquerels/cubic meter • Working levels Consider. Lesson 46 Measuring radon in residential properties What are the units for measuring radon? Notes What are the EPA action levels for these methods of measurement? Correct numbers: • 4 pCi/l • 148 Bq/m 3 • 0.02 WL See slide 423. We also talked about factors that affect the measurement of radon and radon decay products, including • Air circulation • Ventilation • Air filters • Particles in the air These factors are important when we consider the conditions necessary for testing a home. See slide 424. Consider. Do you have any questions about the units for measuring radon? See slide 425. Check comprehension. See handout 42A. This comprehension check is not graded. Now you’re going to see whether you remember the main points that we’ve discussed in this lesson. Please answer the questions on handout 42A. When you all finish, we’ll review the answers together. Review the answers.