#10 CAN SEAMER INSTRUCTIONS (For Gering Portable Seamer)

Setting Up

1. Fasten seamer securely to table using “C” clamps. 2. Verify base height setting: a. Place a on an empty can and place the can on the round baseplate. b. Raise the can to upper locked position by lifting up on the base clamp handle. c. If the base clamp handle does not snap firmly into upper, locked position, loosen the lock nut, adjust the spindle height, and retighten the lock nut. d. Lower base and remove empty can. 3. Plug in seamer. 4. Cut open top of containing oxygen absorbers. Remove only enough packets for the next 20 to 30 minutes. Reseal bag with the special clamp provided. Reopen and reseal bag as additional absorbers are needed.

Filling Cans

1. Fill can to within ¼ inch of top of can. 2. Place an oxygen absorber in the top of can. 3. the lid or can to identify the product. 4. Place a lid on the can.

Seaming Cans

1. Place the filled can onto the sealer base and raise to upper locked position. 2. Turn on motor by pushing in and holding the switch, using the left hand thumb. 3. PUSH roll lever slowly in to fully engage 1st operation roll. 4. Hold firmly in place for 3 revolutions. 5. PULL roll lever to fully engaged 2nd operation roll position. 6. Hold firmly in place for 3 revolutions. 7. Release motor switch to turn off motor, lower base, and remove can.

Inspecting Seam

1. Visually inspect the completed seam to see that it is the same as the factory seamed end. a. If the seam has droops, make certain that the 1st operation roll is fully engaged on the next can. b. If the seam has not been flattened adequately, hold more pressure in the 2nd operation.

CAUTION: Keep children away from this machine while operating.

28 April 2005