Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho a Dissertation

Total Page:16

File Type:pdf, Size:1020Kb

Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho a Dissertation Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems By Tony Ho A dissertation submitted in partial satisfaction of the requirements for the degree of Doctor of Philosophy in Engineering – Mechanical Engineering in the Graduate Division of the University of California, Berkeley Committee in charge: Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair Professor Van P. Carey Professor Per F. Peterson Spring 2012 Abstract Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems by Tony Ho Doctor of Philosophy in Mechanical Engineering University of California, Berkeley Professor Ralph Greif, Co-Chair Professor Samuel S. Mao, Co-Chair The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially increase power generation and improve the utilization efficiency of renewable energy and waste heat recovery systems. A brief review of current advanced vapor power cycles including the Organic Rankine Cycle (ORC), the zeotropic Rankine cycle, the Kalina cycle, the transcritical cycle, and the trilateral flash cycle is presented. The premise and motivation for the OFC concept is that essentially by improving temperature matching to the energy reservoir stream during heat addition to the power cycle, less irreversibilities are generated and more power can be produced from a given finite thermal energy reservoir. In this study, modern equations of state explicit in Helmholtz energy such as the BACKONE equations, multi-parameter Span- Wagner equations, and the equations compiled in NIST REFPROP 8.0 were used to accurately determine thermodynamic property data for the working fluids considered. Though these equations of state tend to be significantly more complex than cubic equations both in form and computational schemes, modern Helmholtz equations provide much higher accuracy in the high pressure regions, liquid regions, and two-phase regions and also can be extended to accurately describe complex polar fluids. Calculated values of saturated liquid and vapor density and vapor pressure were then compared to values listed in the NIST Chemistry WebBook to ensure accuracy for the temperature range of interest. Deviations from the NIST WebBook were typically below 1%; a comparison of first law efficiencies for an ideal basic Rankine cycle yielded less than 0.4% difference between calculations using the Helmholtz-explicit equations of state and NIST REFPROP. Also by employing the BACKONE and Span-Wagner equations, the number of potential aromatic hydrocarbon and siloxane working fluids that are appropriate for high and intermediate temperature applications is expanded considerably. A theoretical investigation on the OFC is conducted using the aforementioned Helmholtz- explicit equations of state for 10 different aromatic hydrocarbon and siloxane working fluids for intermediate temperature finite thermal energy reservoirs (~300oC). Results showed that aromatic hydrocarbons to be the better suited working fluid for the ORC and OFC due to less “drying” behavior and also smaller turbine volumetric flow ratios resulting in simpler turbine designs. The single flash OFC is shown to achieve utilization efficiencies that are comparable to 1 the optimized basic ORC (~0.63) which is used as a baseline. It is shown that the advantage of improved temperature matching during heat addition was effectively negated by irreversibilities introduced into the OFC during flash evaporation. Several improvements to the basic OFC are proposed and analyzed such as introducing a secondary flash stage or replacing the throttling valve with a two-phase expander. Utilization efficiency gains of about 10% over the optimized basic ORC can be achieved by splitting the expansion process in the OFC into two steps and recombining the liquid stream from flash evaporation prior to the secondary, low pressure, expansion stage. Results show that the proposed enhancements had a more pronounced effect for the OFC using aromatic hydrocarbon working fluids (5-20% utilization efficiency improvement) than for siloxane working fluids (2-4%). The proposed modifications were aimed towards reducing irreversibility in flash evaporation; it was observed for siloxanes that the primary source of irreversibility was due to high superheat at the turbine exhaust because of the highly “drying” nature of the fluid. Though an order of magnitude analysis, results showed that the OFC and ORC to require similar heat transfer surface areas. For low temperature thermal energy reservoirs (80-150oC) applicable to non-concentrated solar thermal, geothermal, and low grade industrial waste heat energy, alkane and refrigerant working fluids possess more appropriate vapor pressures. The optimized single flash OFC was again shown to generate comparable power per unit flow rate of the thermal energy reservoir than the optimized basic ORC. With some of the previously proposed design modifications though, the OFC can produce over 60% more power than the optimized ORC. For low temperature applications, the minimum temperature difference between streams in the heat exchanger, or pinch temperature, becomes an important design parameter. Reduction of the pinch temperature even slightly can yield significantly higher gains in power output, but will also increase required heat exchanger surface area and subsequently capital costs. A high-level design of a liquid-fluoride salt (NaF-NaBF4) cooled solar power tower plant is presented; liquid-fluoride salt is used rather than current molten nitrate salts to increase the receiver temperature and subsequently allow for higher efficiency gas power cycles to be used. Graphite or direct energy storage in the salt itself is proposed. The power block component of this heliostat-central receiver plant is a combined cycle system consisting of a topping Brayton cycle with intercooling, reheat, and regeneration and a bottoming low-temperature modified OFC. The combined cycle is designed with dry cooling in mind, such that operation in desert climates are more suitable. The combined cycle design is shown to increase power block efficiencies by 6%-8% over the Brayton cycle with intercooling, reheat, and regeneration alone. An estimated 30% annual average total solar-to-electric conversion efficiency is possible with this system design, which is comparable to some of the most efficient high temperature solar power tower designs to date. Theoretically, power block efficiencies over 60% are possible; however, emission losses from the isothermal central receiver would limit the plant’s operational temperature range. Results show that for high efficiency solar power towers to be realized, high temperature non-isothermal, or partitioned, receivers operating efficiently above 1000oC are necessary. Other potential areas of renewable energy system integration for the OFC include a co-generation solar thermal-photovoltaic system that employs highly concentrated, densely packed photovoltaic cells using single-phase or two-phase cooling. The thermal energy absorbed by that coolant could then be used as the working fluid in a separate OFC to further produce power in co-generation with the concentrated photovoltaics. 2 Dedication This dissertation is dedicated to my mother and father, Tracy and Yick Han Ho; I owe everything to their love, their hard work and sacrifices, and the character that they have instilled in me. This dissertation is also dedicated in loving memory of my grandfather. i Table of Contents Abstract ........................................................................................................................................... 1 Dedication ........................................................................................................................................ i List of Figures ................................................................................................................................. v List of Tables ................................................................................................................................. ix Nomenclature .................................................................................................................................. x Acknowledgements ...................................................................................................................... xiii 1 Introduction ............................................................................................................................. 1 1.1 Background on thermal energy conversion systems ........................................................ 1 1.2 Review of advanced vapor power cycles for finite thermal sources ................................ 3 1.2.1 Steam Rankine cycle ................................................................................................. 3 1.2.2 Organic Rankine Cycles (ORC)................................................................................ 5 1.2.3 Zeotropic vapor cycles ............................................................................................ 10 1.2.4 Transcritical and supercritical cycles ...................................................................... 13 1.2.5 Trilateral flash cycle ............................................................................................... 15 1.3 Motivation for the Organic Flash Cycle (OFC) ............................................................. 15 1.4 Outline of dissertation
Recommended publications
  • Performance Analysis of Two-Stage Transcritical Refrigeration Cycle Operating with R744
    Proceedings of COBEM 2011 21 st Brazilian Congress of Mechanical Engineering Copyright © 2011 by ABCM October 24-28, 2011, Natal, RN, Brazil PERFORMANCE ANALYSIS OF TWO-STAGE TRANSCRITICAL REFRIGERATION CYCLE OPERATING WITH R744 Igor Marcel Gomes Almeida, [email protected] Studies Group in Refrigeration and Air-Conditioning. Federal Institute of Education, Science and Technology of Rio Grande do Norte. Santa Cruz-RN. Cleiton Rubens Formiga Barbosa, [email protected] Francisco de Assis Oliveira Fontes, [email protected] Federal University of Rio Grande do Norte. Department of Mechanical Engineering. Abstract. The present study is a theoretical analysis of a two-stage transcritical cooling cycle using R744 (carbon dioxide) as a refrigerant. The effect of the intercooling process on performance in the two-stage transcritical system is subjected to varying pressures in a gas cooler. Performance comparison between the single stage and two-stage cycle is also subject to the same operating conditions. We assessed the effects on system performance of pressure in the gas cooler, isentropic compressor efficiency, amount of intercooling between the two compression stages and discharge temperature of the refrigerant from the gas cooler. Thermodynamic analysis was carried out with CoolPack software, considering an evaporation temperature of -10 oC and refrigeration capacity of 5 kW. Results show the coefficient of performance (COP) for the two-stage cycle is superior to the single stage cycle. Two-stage compression was found to reduce energy consumption. On the whole, two-stage compression and the intercooling process are significant in increasing COP for these systems. Keywords : Natural refrigerants, Carbon dioxide, Performance, Two-stage compression, Transcritical cycle.
    [Show full text]
  • Performance Comparison of Different Rankine Cycle Technologies Applied to Low and Medium Temperature Industrial Surplus Heat Scenarios
    Paper ID: 175 Page 1 Performance Comparison of Different Rankine Cycle Technologies Applied to Low and Medium Temperature Industrial Surplus Heat Scenarios Goran Durakovic1*, Monika Nikolaisen2 SINTEF Energy Research, Gas technology, Trondheim, Norway [email protected] [email protected] * Corresponding Author ABSTRACT Energy intensive industries generate vast amounts of low-grade surplus heat, and potential for direct re- use can be limited due to insufficient local demand. Conversion of heat into electric power thus becomes an attractive option. However, heat-to-power conversion is limited by poor efficiencies for heat sources at low and medium temperatures. To optimally utilize the available energy, the choice of technology could be important. In this work, single-stage subcritical, dual-stage subcritical and single-stage transcritical Rankine cycle technologies were compared. The investigated heat sources are an air equivalent off-gas at 150°C and 200°C and a liquid heat source at 150°C. These were all evaluated with the same available duty. The Rankine cycles were compared with equal total heat exchanger areas to enable fair comparisons of different cycles, instead of comparing cycles based on equal pinch point temperature differences as is frequently reported in literature. Six working fluids were investigated for both heat source temperatures, and cycle optimization was performed to determine the best Rankine cycle for each working fluid. This means that the optimizer could choose between single-stage and dual-stage cycle during one optimization, and determine which gave the highest net power output. The results were benchmarked against single-stage subcritical Rankine cycles. The results showed that the cycle yielding the highest net power varied depending on the allowable total heat exchanger area.
    [Show full text]
  • Particular Characteristics of Transcritical CO2 Refrigeration Cycle with an Ejector
    Applied Thermal Engineering 27 (2007) 381–388 www.elsevier.com/locate/apthermeng Particular characteristics of transcritical CO2 refrigeration cycle with an ejector Jian-qiang Deng a, Pei-xue Jiang b,*, Tao Lu b, Wei Lu b a Department of Process Equipment and Control Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China b Key Laboratory for Thermal Science and Power Engineering, Department of Thermal Engineering, Tsinghua University, Beijing 100084, China Received 4 April 2005; accepted 16 July 2006 Available online 26 September 2006 Abstract The present study describes a theoretical analysis of a transcritical CO2 ejector expansion refrigeration cycle (EERC) which uses an ejector as the main expansion device instead of an expansion valve. The system performance is strongly coupled to the ejector entrain- ment ratio which must produce the proper CO2 quality at the ejector exit. If the exit quality is not correct, either the liquid will enter the compressor or the evaporator will be filled with vapor. Thus, the ejector entrainment ratio significantly influences the refrigeration effect with an optimum ratio giving the ideal system performance. For the working conditions studied in this paper, the ejector expansion sys- tem maximum cooling COP is up to 18.6% better than the internal heat exchanger cycle (IHEC) cooling COP and 22.0% better than the conventional vapor compression refrigeration cycle (VCRC) cooling COP. At the conditions for the maximum cooling COP, the ejector expansion cycle refrigeration output is 8.2% better than the internal heat exchanger cycle refrigeration output and 11.5% better than the conventional cycle refrigeration output.
    [Show full text]
  • Compression of an Ideal Gas with Temperature Dependent Specific
    Session 3666 Compression of an Ideal Gas with Temperature-Dependent Specific Heat Capacities Donald W. Mueller, Jr., Hosni I. Abu-Mulaweh Engineering Department Indiana University–Purdue University Fort Wayne Fort Wayne, IN 46805-1499, USA Overview The compression of gas in a steady-state, steady-flow (SSSF) compressor is an important topic that is addressed in virtually all engineering thermodynamics courses. A typical situation encountered is when the gas inlet conditions, temperature and pressure, are known and the compressor dis- charge pressure is specified. The traditional instructional approach is to make certain assumptions about the compression process and about the gas itself. For example, a special case often consid- ered is that the compression process is reversible and adiabatic, i.e. isentropic. The gas is usually ÊÌ considered to be ideal, i.e. ÈÚ applies, with either constant or temperature-dependent spe- cific heat capacities. The constant specific heat capacity assumption allows for direct computation of the discharge temperature, while the temperature-dependent specific heat assumption does not. In this paper, a MATLAB computer model of the compression process is presented. The substance being compressed is air which is considered to be an ideal gas with temperature-dependent specific heat capacities. Two approaches are presented to describe the temperature-dependent properties of air. The first approach is to use the ideal gas table data from Ref. [1] with a look-up interpolation scheme. The second approach is to use a curve fit with the NASA Lewis coefficients [2,3]. The computer model developed makes use of a bracketing–bisection algorithm [4] to determine the temperature of the air after compression.
    [Show full text]
  • Analysis of a CO2 Transcritical Refrigeration Cycle with a Vortex Tube Expansion
    sustainability Article Analysis of a CO2 Transcritical Refrigeration Cycle with a Vortex Tube Expansion Yefeng Liu *, Ying Sun and Danping Tang University of Shanghai for Science and Technology, Shanghai 200093, China; [email protected] (Y.S.); [email protected] (D.T.) * Correspondence: [email protected]; Tel.: +86-21-55272320; Fax: +86-21-55272376 Received: 25 January 2019; Accepted: 19 March 2019; Published: 4 April 2019 Abstract: A carbon dioxide (CO2) refrigeration system in a transcritical cycle requires modifications to improve the coefficient of performance (COP) for energy saving. This modification has become more important with the system’s more and more widely used applications in heat pump water heaters, automotive air conditioning, and space heating. In this paper, a single vortex tube is proposed to replace the expansion valve of a traditional CO2 transcritical refrigeration system to reduce irreversible loss and improve the COP. The principle of the proposed system is introduced and analyzed: Its mathematical model was developed to simulate and compare the system performance to the traditional system. The results showed that the proposed system could save energy, and the vortex tube inlet temperature and discharge pressure had significant impacts on COP improvement. When the vortex tube inlet temperature was 45 ◦C, and the discharge pressure was 9 MPa, the COP increased 33.7%. When the isentropic efficiency or cold mass fraction of the vortex tube increased, the COP increased about 10%. When the evaporation temperature or the cooling water inlet temperature of the desuperheater decreased, the COP also could increase about 10%. The optimal discharge pressure correlation of the proposed system was established, and its influences on COP improvement are discussed.
    [Show full text]
  • Eindhoven University of Technology MASTER Counterflow Pulse-Tube
    Eindhoven University of Technology MASTER Counterflow pulse-tube refrigerator Franssen, R.J.M. Award date: 2001 Link to publication Disclaimer This document contains a student thesis (bachelor's or master's), as authored by a student at Eindhoven University of Technology. Student theses are made available in the TU/e repository upon obtaining the required degree. The grade received is not published on the document as presented in the repository. The required complexity or quality of research of student theses may vary by program, and the required minimum study period may vary in duration. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain Technische Universiteit Eindhoven Faculteit Technische Natuurkunde Capaciteitsgroep Lage Temperaturen Counterflow pulse-tube refrigerator R.J.M. Franssen Prof. Dr. A.T.A.M. de Waele (supervisor and coach) May 2001 Abstract Abstract In this report we discuss a new type of pulse-tube refrigerator. A pulse-tube refrigerator is a cooler with no moving parts in the cold region. This has the advantage that the cooler is simpler and more reliable, and it also reduces vibrations, which is useful in several applications.
    [Show full text]
  • Energy Efficiency State of the Art of Available Low-Gwprefrigerants And
    ENERGY EFFICIENCY STATE OF THE ART OF AVAILABLE LOW-GWP REFRIGERANTS AND SYSTEMS Final Report September 2018 Study commissioned by the AFCE and carried out by EReIE, the Cemafroid, and the CITEPA Authors : Stéphanie Barrault (CITEPA) Olivier Calmels (Cemafroid) Denis Clodic (EReIE) Thomas Michineau (Cemafroid) ACKNOWLEDGEMENTS We sincerely thank the members of the Steering Committee for their contributions: Bénédicte BALLOT-MIGUET, EDF Emmanuelle BRIERE, UNICLIMA Tristan HUBE, Service Entreprises et Dynamiques Industrielles, ADEME Laurent GUEGAN, François HEYNDRICKX, Régis LEPORTIER, François PIGNARD, AFCE. We would also like to thank all the professionals contacted as part of the study Copyright 2018 Any representation or reproduction in whole or in part without the consent of the authors or their heirs or successors is illegal according to the Code of Intellectual Property (Art. L 122-4) and constitutes an infringement punishable under the Criminal Code. Only are allowed (art. 122-5) copies or reproductions strictly reserved for private use and not intended for collective use, as well as analyzes and short quotations justified by the critical pedagogical character, or information the work to which they are incorporated, subject, however, to compliance with the provisions of Articles L122-10 to L122-12 of the Code, relating to reprographic reproduction. 2 / 131 Content CONTENT Content 3 List of Figures _________________________________________________________________ 6 List of Tables _________________________________________________________________
    [Show full text]
  • Thermodynamic Modeling of an Atkinson Cycle with Respect to Relative AirFuel Ratio, Fuel Mass Flow Rate and Residual Gases R
    Vol. 124 (2013) ACTA PHYSICA POLONICA A No. 1 Thermodynamic Modeling of an Atkinson Cycle with respect to Relative AirFuel Ratio, Fuel Mass Flow Rate and Residual Gases R. Ebrahimi∗ Department of Agriculture Machine Mechanics, Shahrekord University, P.O. Box 115, Shahrekord, Iran (Received March 26, 2013; in nal form April 17, 2013) The performance of an air standard Atkinson cycle is analyzed using nite-time thermodynamics. The results show that if the compression ratio is less than a certain value, the power output increases with increasing relative airfuel ratio, while if the compression ratio exceeds a certain value, the power output rst increases and then starts to decrease with increase of relative airfuel ratio. With a further increase in compression ratio, the increase in relative airfuel ratio results in decrease of the power output. Throughout the compression ratio range, the power output increases with increase of fuel mass ow rate. The results also show that if the compression ratio is less than a certain value, the power output increases with increase of residual gases, on the contrast, if the compression ratio exceeds a certain value, the power output decreases with increase of residual gases. The results obtained herein can provide guidance for the design of practical Atkinson engines. DOI: 10.12693/APhysPolA.124.29 PACS: 05.70.Ln, 82.60.Fa, 88.05.−b 1. Introduction formance of an air standard Atkinson cycle under the re- striction of the maximum cycle temperature. The results The Atkinson cycle is a type of internal combustion show that the power output as well as the eciency, for engine, which was designed and built by a British engi- which the maximum power-output occurs, will rise with neer James Atkinson in 1882.
    [Show full text]
  • Thermodynamic Analysis on a Novel Gas-Gas Ejector Enhanced
    Purdue University Purdue e-Pubs International Refrigeration and Air Conditioning School of Mechanical Engineering Conference 2016 Thermodynamic Analysis On A Novel Gas-gas Ejector Enhanced Autocascade Refrigeration Cycle Jiaheng Chen Xi'an Jiaotong University, China, People's Republic of, [email protected] Jianlin Yu Xi'an Jiaotong University, China, People's Republic of, [email protected] Gang Yan Xi'an Jiaotong University, China, People's Republic of, [email protected] Follow this and additional works at: http://docs.lib.purdue.edu/iracc Chen, Jiaheng; Yu, Jianlin; and Yan, Gang, "Thermodynamic Analysis On A Novel Gas-gas Ejector Enhanced Autocascade Refrigeration Cycle" (2016). International Refrigeration and Air Conditioning Conference. Paper 1731. http://docs.lib.purdue.edu/iracc/1731 This document has been made available through Purdue e-Pubs, a service of the Purdue University Libraries. Please contact [email protected] for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html 2396, Page 1 Thermodynamic Analysis On a Novel Gas-gas Ejector Enhanced Autocascade Refrigeration Cycle Jiaheng Chen1, Jianlin Yu1*, Gang Yan1 1Xi’an Jiaotong University, Department of Refrigeration & Cryogenic Engineering, Xi’an 710049, China *Email: [email protected] ABSTRACT A novel gas-gas ejector enhanced autocascade refrigeration cycle is proposed in this paper. The novel cycle uses an additional gas-gas ejector and a phase separator to accomplish a secondary composition separation for the zeotropic mixture used in the cycle. This proposed cycle can lift the evaporating pressure for a specific evaporating pressure and further improve the cycle performance.
    [Show full text]
  • Comparison of the Organic Flash Cycle (OFC) to Other Advanced Vapor Cycles for Intermediate and High Temperature Waste Heat Reclamation and Solar Thermal Energy
    Energy 42 (2012) 213e223 Contents lists available at SciVerse ScienceDirect Energy journal homepage: www.elsevier.com/locate/energy Comparison of the Organic Flash Cycle (OFC) to other advanced vapor cycles for intermediate and high temperature waste heat reclamation and solar thermal energy Tony Ho*, Samuel S. Mao, Ralph Greif Department of Mechanical Engineering, University of California-Berkeley, Etcheverry Hall, Berkeley, CA 94720, USA article info abstract Article history: The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially improve the Received 27 August 2011 efficiency with which high and intermediate temperature finite thermal sources are utilized. The OFC’s Received in revised form aim is to improve temperature matching and reduce exergy losses during heat addition. A theoretical 22 February 2012 investigation is conducted using high accuracy equations of state such as BACKONE, SpaneWagner, and Accepted 24 March 2012 REFPROP in a detailed thermodynamic and exergetic analysis. The study examines 10 different aromatic Available online 22 April 2012 hydrocarbons and siloxanes as potential working fluids. Comparisons are drawn between the OFC and an optimized basic Organic Rankine Cycle (ORC), a zeotropic Rankine cycle using a binary ammonia-water Keywords: Organic Rankine Cycle (ORC) mixture, and a transcritical CO2 cycle. Results showed aromatic hydrocarbons to be the better suited fl Solar thermal working uid for the ORC and OFC due to higher power output and less complex turbine designs. Results Waste heat also showed that the single flash OFC achieves comparable utilization efficiencies to the optimized basic Vapor cycle ORC. Although the OFC improved heat addition exergetic efficiency, this advantage was negated by Exergy analysis irreversibilities introduced during flash evaporation.
    [Show full text]
  • Capacitive Sensors Measuring the Vapor Quality, Phase of the Refrigerant and Ice Thickness for Optimized Evaporator Performance Michael Elstroem, Btecman & Mareng
    10.18462/iir.gl.2018.1150 Capacitive Sensors Measuring the Vapor Quality, Phase of the refrigerant and Ice thickness for Optimized evaporator performance Michael Elstroem, BTecMan & MarEng. Technical Manager HB Products A/S, Hasselager, 8361, Denmark, [email protected] 1. ABSTRACT New measurement methods make it possible to design more energy-efficient Low Charge Systems with Zero Superheat as well as demand driven defrost with increasing safety aspects when using natural refrigerants as Ammonia, Propane and CO2. Increasing energy prices as well as requirements to reduce global warming (GWP) and CO2 emissions have encouraged the need for using natural refrigerants which have initiated numerous of new efforts and developments worldwide. Applications using new measurement principles and design methods in the refrigeration industry may significantly affect the objective of lower global power consumption with a reduction of 20 to 40% while increasing the safety by minimizing and controlling the refrigerant charge with a reduction factor of up to 1000 times for Ammonia DX vs. a traditional pump circulated system. 2. INTRODUCTION This paper describes a new sensor system for optimizing Evaporator Control including description of the measurement principle for measuring the phase of refrigerant as Vapor Quality. In this paper it is described how the “X”-sensor measures Vapor Quality as degree of dryness and how a demand driven defrost sensor measures the ice build-up (thickness) on the surface of the air cooler. This paper does also provide information about sensor design, laboratory testing, system design, field testing, applications, summary and conclusions. Experience in testing and installation on primary Ammonia systems have proven that a Vapor Quality Sensor mounted in the outlet of an evaporator optimizes the entire system and makes it possible to control and limit the amount of refrigerant in the system under all conditions (including part load operation).
    [Show full text]
  • Thermodynamic Data
    Thermodynamic Data It is not possible to know the absolute value of U ˆ or H ˆ for a pure substance, but you can determine the change in U ˆ ( U ˆ ) or Hˆ ( Hˆ ) corresponding to a specified change of state (temperature, pressure, and phase). The change is actually often what we want to know. A common practice is to arbitrarily designate a reference state for a substance at which U ˆ and H ˆ are arbitrarily set to be equal to zero, and then tabulate U ˆ and/or H ˆ for the substance relative to the reference state. For example, ˆ CO (g, 0C, 1 atm) CO (g,100C, 1 atm): HCO 2919 J/mol ˆ ˆ reference state HCO HCO 0 2919 J/mol We say: “The specific enthalpy of CO at 100C and 1 atm relative to CO at 0C and 1 atm is 2919 J/mol”. CHEE 221 1 Reference States and State Properties Most (all?) enthalpy tables report the reference states (T, P and State) on which the values of H ˆ are based; however, it is not necessary to know the reference state to calculate H (change in enthalpy) for the transition from one state to another. ˆ ˆ –H from state 1 to state 2 equals H 2 H 1 regardless of the reference state upon which ˆ and ˆ were based H1 H 2 – Caution: If you use different tables, you must make sure they have the same reference state This result is a consequence of the fact that H ˆ (and U ˆ ) are state properties, that is, their values depend only on the state of the species (temperature, pressure, state) and not on how the species reached its state.
    [Show full text]