<<

Fourier Transform Holography Single Shot on a Photon Budget

Bill Schlotter

Applied Physics, Stanford University Stanford Radiation Laboratory SLAC The General Idea

• Lensless imaging with soft x-rays • holography • High spatial resolution • Full field Outline

• Motivation and the phase problem • Fourier Transform Holography (FTH) • Experimental Instruments • Capabilities of FTH for stroboscopic imaging – Improve quality – Extend the field of view – Record multiple image with a single pulse – Extend the dynamic range of detection Synchrotron Sources

BESSY SSRL at SLAC Berlin, Germany Menlo Park, California

Undulator

Tunable light source: Soft x-rays: Energy E=100eV – 1000 eV Polarization λ =12.4 nm – 1.2 nm Tunable light source: Energy Polarization

Full Field X-ray – Real Space Imaging

Transmission X-ray Microscopy

Magnetic Worm Domain Pattern State of the art resolution is 20-40nm Progress in the Ultrafast and Ultrasmall

No ultrafast probe of structure on the nanoscale

• No ultrafast probes of structure on the nanoscale Single Shot Imaging to study: Non Periodic Structures Ultrafast dynamics on relevant length scales Ultrafast Lensless Imaging Systems in their “natural” state

Linac Coherent Light Source 1013 coherent soft x-ray photons per pulse

FEL 4th Generation Light Sources:  (soft x-ray 2007) LCLS (hard x-ray 2009)

Single Shot Image Requires: Full field microscopy Coherent x-ray compatibility High peak brightness Ability to cope with high power load Some Requirements for Frontier Experiments: High resolution with large field of view Weak scattering system with poor contrast Minimal beam induced sample perturbation

At grade in RSY Partially e c

Coherent a p

Light Source s

z # Spatial Filter " = Pinhole T 2 $ d

Spectral Filter Grating L = ! 2 Monochrometer e

Coherent c a

Light p s

A. Schawlow, Sci. Am. 219, 120 (1968) Tunable light source: Add Illustration Energy Polarization

Coherence time

Current x-ray sources are not intrinsically coherent

Synchrotron Radiation Synchrotron is a chaotic source, but: Undulator source at 3rd generation synchrotron allows to extract a high coherent flux

Photons in volume ∼ Brightness · λ3

Give typical coherence 2D Nature 432, p885 Dec.C 1o6h, 2e0re04nce Filter Sample Detector Values and what dimensions They must exceed on the experiment P1 P2 20µm Synchrotron

Monochromator Radiation Pinholes The Phase Problem

Coherent Illumination

Autocorrelation

Fourier Transform

Scattering amplitude is complex, but measurement detects the intensity only: Tunable light source: Energy Polarization

Fourier Transform Holography

S. Eisebitt, J. Lüning, W. F. Schlotter, M. Lörgen, O. Hellwig, W. Eberhardt, and J. Stöhr. Lensless Imaging of Magnetic Nanostructures by x-ray Spectro-holography. Nature, 432 p885, 2004.

Nature 432, p885 Dec. 16, 2004 Tunable light source: Energy Polarization

A Lensless Image

Intensity 2D Fourier Transform

Fourier Transform Hologram Two methods for finding the phase. Only the intensity of the photon can be detected. Got Phase?

1) Fourier Holography True imaging •1963-1965 FTH with visible light technique • 1963-1965 FTH at λ= 632nm –Winthrop & Worthington – Leith & Upatnieks –Stroke & Falconer – Winthrop & Worthington •1972 FTH at λ= 6.0 nm – Stroke & Falkner –Aoki & Kikuta •1991 FTH at λ= 3.4 nm • 1972 FTH at λ= 6.0 nm –McNulty et. al – Aoki & Kikuta

2) Iterative Phase Retrieval No proof that • Not a true imaging technique • 1991 FTH at λ= 3.4 nm the solution • Capable of limited resolution – McNulty et. al is unique •1952 Sayre •1972 Gerchberg-Saxon --Error Reduction •1982 Fineup --Hybrid Input-Output •2003 Elser --Difference Map

Solutions not unique Tunable light source: Energy Polarization

Reconstructing the Object Intensity

object 2D Fourier Transform

reference

Fourier Transform Hologram Lensless Imaging with 50nm Resolution

Conventional x-ray Lensless image microscope image * *

WhiteW

* Fourier transform FTH is an imaging method holography is an imaging method BlackB Integrated Sample Structure

Gold

. Patterned with focused Gold ion beam milling 100nm 100nm •Patterned by Focused Ion Beam Milling Silicon Unity transmission Nitride •Metal nanostructures with 10:1 aspect reference ratio are achievable with the FIB Magnetic Multilayer •A 100 nm reference hole can be Mask and sample fixed patterned in 1.0um of Gold.

•One micron of Au is 15 attenuation lengths at 800eV. High contrast! Patterned by Focused Ion Beam Milling

•For soft x-rays high aspect ratio features enable high contrast features References and Resolution Tunable light source: Energy Polarization

(S)ampelmännchen Focused Ion Beam Milling

FEI Strata 235 DB Ion Beam Milling Dual Beam FIB Ga+ @ 30 kV Current ~ 1pA - 20nA `

Tunable light source: Energy Polarization CCD and Beam-stops

Commercial CCD PI-MTE 1300 x 1340B Princeton Instruments PI-MTE Backside illuminated In-vacuum operation 10-6 Torr 1300 x 1340 20 µm pitch

ADC @ 1MHz Depth: 16-bit Noise: 10 e- rms

Dynamic range 200k e- full well 3 10 800eV photons In Vacuum Soft X-ray CCD

Princeton Instruments

In-vacuum CCD •Princeton Instruments •PI-MTE 16-bit •Backside illumination 1300 x 1340 pixels 20 µm pixel pitch Coherent Scattering Endstation

SSRL Beamline 5-2 UHV Beam

Operation Parameters 5 ms response 2.75 inch CF flange 10-10 torr Single Shot Imaging on a Photon Budget Single Shot Imaging on a Photon Budget

Photon Flow Experimental Transaction In Out Number of Photons per Pulse 1013 High Image Contrast Nγ High Image Spatial Resolution NγNγ High Image Signal-to Noise Ratio NγNγNγ Huge Image Field of View NγNγNγNγ Multiple (M images) MNγ Photon Frugal

High Quality Imaging High Spatial Resolution Single Shot Imaging on a Photon Budget High Contrast High Signal-to-Noise Ratio Huge Field of View Restrictions on Image Quality Photon Frugality Sample Limited  Improved signal to noise Radiation sensitive sample Extending the field of view Source Limited Phase contrast Finite number of photons Five Images for the Price of One Multiple Reference Holes

FTH Mask Fourier Transform Holography Mask

Focused Ion Beam Front Back milling was used to pattern the Au structure.

The block letter F is the sample and has .77µm an intensity transmittance of 12% at 780eV

All five reference holes penetrate the 1.0µm entire structure with a mean diameter of 140±6nm .22µm W. F. Schlotter, R. Rick, K. Chen, et. al., Appl. Phys. Lett. 89 (2006) Coherent Diffraction Pattern

Soft x-ray Fourier transform hologram of FTH mask. E= 780eV

The common logarithm of the detected intensity is plotted.

The hologram contains ~7*106 photons (E= 780eV). photons

Tunable light source: Energy Polarization Autocorrelation

• The squared magnitude of the complex autocorrelation is shown.

• Sub-Images ready for extraction.

• Five sub-images are essentially identical and have the same orientation

• They can be aligned for averaging by cross correlation.

W. F. Schlotter, R. Rick, K. Chen, et. al., Appl. Phys. Lett. 89 (2006)

Tunable light source: Energy Polarization Weak Illumination

Low photon hologram Enlargement containing ~110 photons

photons

Hologram recorded with weak Single photon detection illumination contains only events are clearly visible. 2.5*103 photons.

Tunable light source: Energy Polarization Reconstruction and SNR

Single sub-image

SNR1 ~ 3

SNR N = N SNR1

5 sub-image composite

SNR N = N SNR1

SNR 5 ~ 9

Low Noise Signal, s, is the mean value of Signal to Noise Ratio (SNR) pixel on the sample SNR N = s/" b Where N is the number of Noise, σb, is the standard deviation of the pixels in the images averaged in the surrounding area. composite sub image. !

(a) Hologram obtained with only 2.5 x 103 detected photons. Scale bar Tunableshows d elighttected psource:hotons/pixel. (b) Enlarged section contains 110 ± 10 photons. (c) Sample is very faint in single sub-image with SNR ~ 3. (d) EnergySample is clearly recognizable in composite image with SNR ~ 9. Polarization High Resolution Huge Field of View Extended Field of View Test

Holographic Mask

Strategic reference and object hole arrangement enables an effective increase in field of view.

Idea introduced with visible light by J. Goodman in 1968.

W.F. Schlotter, et. al, Submitted Hologram and reconstruction

Tunable light source: Energy Polarization Comparing real space images

Tunable light source: Energy Polarization Resolving Fringes

z Far Field Camera Translation: Zoom

Hologram Autocorrelation Single Shot Stopwatch Pump Probe

Temporal resolution set by delay synchronization

Photo- Diode Intensity

Delay (fs) Cross-Beam Pump Probe

Resilient to pulse arrival

Probe pulse

Pump pulse Lindenberg, et. al, Science , 2005, 308, p392 Panoramic Imaging over 180 µm

A scale illustration of Au transmission mask structure.

• The 70nm reference holes will provide high resolution reconstruct ions of the arrow structures.

Tunable light source: Energy Polarization Panoramic Field of View

W.F. Schlotter, et. al, Letters, Accepted

Tunable light source: Energy Polarization Toward Ultrafast Evolution

Probe pulse

Pump pulse

Tunable light source: Energy Polarization Single Shot Stopwatch

The reconstruction of the hologram relates the position of the arrows to their relative time since excitation.

W.F. Schlotter, et. al, Optics Letters, Accepted Increasing Dynamic Range Gaussian Absorption Beamstop Patterned Prototype

Concentric disks were Sacrificial test sample formed by Focused Ion Beam Pt deposition

Sacrificial test sample. Testing the Beamstop

300µm Enhanced Dynamic Range Conclusions

• Lensless imaging at soft x-ray is robust and ready for single shot experiments • Integrated mask is the key • High spatial resolution • Single shot – Improved SNR – Extended Field of View – Single shot clock • Future is Bright Coherence Crew

Ramon Rick Shampa Sarkar Kang Chen Andreas Scherz Sujoy Roy Jo Stöhr (Thesis Advisor)

Christian Günther Stefan Eisebitt

Insert APS logo Jan Lüning Ian McNulty

Tai-Hee Kang Olav Hellwig