PURSUING HIGH-RISE MULTIFAMILY ENERGY EFFICIENCY IN SEATTLE
MAY 2019 EXECUTIVE SUMMARY In 2018, over ten thousand residential units were for code compliance was re-purposed to test a number of built or approved to be built in high-rise buildings scenarios employing a range of ECMs needed to design and throughout Downtown Seattle, South Lake Union construct a code-compliant building in each future code cycle. and First Hill.1 There is no question that high-rise multifamily (HRMF) buildings account for a significant Conclusion 1: The results for future code compliance are not percentage of new dwelling units in Seattle. Of as challenging as one might think. This study found that the particular interest to developers, architects, engineers following energy conservation measures (ECMs) resulted in and city officials is how the continued evolution of the anticipated code compliance for Nexus in the year 2030: Seattle Energy Code (SEC), updated every three years, • Electric boilers will impact the near future design and construction of this building type. • Heat pumps for space heating • Heat pump heating for Domestic Hot Water (DHW) To map the progression of SEC compliance between (e.g. sewer thermal) now and the year 2030, this study was executed in two • Building envelope air tightness measures steps. First, we established a baseline and Energy Use • Lighting power density reduction Intensity (EUI) targets for future code cycles. Then, we identified and tested Energy Conservative Measure • Heat-pump clothes dryers (ECM) packages to meet those targets. • Partial heat pump DHW plant • Reduced unit ventilation Nexus, a single prototypical residential tower designed by Weber Thompson (MEP by Rushing) was chosen for • Reduced corridor pressurization this study in order to test the impacts of energy code and efficiency strategies. The energy model submitted
Seattle Code Projection 50.0 . 3. 0.3 37. 40.0 41.5 41.5 40.0 3 .3 33. 31.1 2 . 33.2 33.2 33.2 2 .2 30.0 28.1 28.1 26.1
20.0 EUI (kBTU/SF/yr)
0 1 3 3 3 0
10.0 ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE ECM PACKAGE 0.0 2006 2009 2012 2015 2018 2021 2024 2027 2030
Predicted EUI reduction 0.0 0.0 3.7 20.0 20.0 20.0 32.3 32.3 37.1 from ECM Package 0
SEC Code Cycle
1 This metric was gathered by Rushing via the Seattle In Progress website (https://www.seattleinprogress.com/), noting projects which have received permit or completed within the last year, and are above 20 stories.
2 PURSUING HIGH-RISE MULTIFAMILY ENERGY EFFICIENCY IN SEATTLE The graph on page 2 illustrates how these strategies (described further on pages 16-17) are added on incrementally with each cycle of the SEC, culminating in the year 2030 with the full list above.
Conclusion 2: The story does not end there. In addition to basic energy code compliance, this study recognizes that Seattle adopted the Green Building Standard in 2016, which consolidated and updated several sections of the land use code. In several areas of the city2, the incentive for additional allowable building height and development potential comes with an additional requirement to perform 15% better than the SEC. This study revisited the model and ECMs with the Green Building Standard in mind, and found that in order to meet this lower energy threshold, additional ECMs would be required in the 2027 and 2030 cycles. These additional measures are more challenging and more impactful to the building design. For Nexus, the additional ECMs shown to comply with the requirement to be 15% better than SEC would include the following:
• Energy recovery ventilation (ERV) for ~50% or more of outside air • Triple pane glazing • Reduced plug loads by 10% or more • Rooftop photovoltaic panels of ~5,000sf or more • Vertical wall photovoltaic panels of 8,000-10,000sf • Reduced window-to-wall ratio (WWR) for building facades from 36.2% to 30% WWR or less
Seattle Green Building Standard Projection
50.0
40.0
32.1 30.9 2 . 30.0 2 . 2 . 28.1 28.1 28.1 22.3 26.1 24.2 20.0 22.17
EUI (kBTU/SF/yr)