WHEATON | Vial Guide
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Method 107 October 7, 2020
Method 107 October 7, 2020 While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. The most recent edits to this method were published here: https://www.gpo.gov/fdsys/pkg/FR-2016-08-30/pdf/2016-19642.pdf. To see a complete version including any recent edits, visit: https://www.ecfr.gov/cgi-bin/ECFR?page=browse and search under Title 40, Protection of Environment. METHOD 107 - DETERMINATION OF VINYL CHLORIDE CONTENT OF IN-PROCESS WASTEWATER SAMPLES, AND VINYL CHLORIDE CONTENT OF POLYVINYL CHLORIDE RESIN SLURRY, WET CAKE, AND LATEX SAMPLES Note: Performance of this method should not be attempted by persons unfamiliar with the operation of a gas chromatograph (GC) nor by those who are unfamiliar with source sampling, because knowledge beyond the scope of this presentation is required. This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling and analytical) essential to its performance. Some material is incorporated by reference from other methods in this part. Therefore, to obtain reliable results, persons using this method should have a thorough knowledge of at least the following additional test methods: Method 106. 1.0 Scope and Application 1.1 Analytes. Analyte CAS No. Sensitivity Vinyl Chloride (CH2:CHCl) 75–01–4 Dependent upon analytical equipment. 1.2 Applicability. This method is applicable for the determination of the vinyl chloride monomer (VCM) content of in-process wastewater samples, and the residual vinyl chloride monomer (RCVM) content of polyvinyl chloride (PVC) resins, wet, cake, slurry, and latex samples. -
Screw Cap Tubes 02 2008.Qxd
FROM THE MANUFACTURER OF SUPERIOR CONSUMABLES TM get NEW Opti-Seal Tear Off Optical disposable for Bud dly frien closure of (q)PCR Strip tubes& (q)PCR plates For Diagnostic & Clinical procedures - Designed to perform diagnostic qPCR and PCR reac tions - Can also be used in Real Time PCR applic ations - Fits All types of PCR an d qPCR plates - Fits all types of 0.1 ml and 0.2 ml PCR an d qPCR 8-tube strips Single sheet Opti-Seal TM tear off Opti-Seal TM tear off positioned on a PCR plate whereas 3 “strips” of seal were removed FEATURES ADVANTAGES BENEFITS Tear Off capability Individual closure of tube strips Minimize cross contamination Economic usage Closure of plates or sections of a Economic usage plate Opening of individual rows of a plate Minimize cross contamination Optical clear Higher S/N rations qPCR applications Low Copy detection Uniform & thick Easy Opening and Closing “finger” and RSI friendly “Elastic Adhesive” Minimize evaporation Consistent reaction conditions Seal mainly based on Adhesive Excellent seal for vessels with flat properties chimney ledge Opti-Seal TM tear off single strip Seal mainly based on “rubber elastic ” Superior seal for vessels with non properties flat (angled)chimney ledge for 100 sheets EU Opti-Seal TM Tear Off Optical disposable adhesive Opti-Seal TM provides the best sealing option for (p)PCR plates and (q)PCR 8-strip tubes- The EU Opti-Seal TM is non pierceable and can be easily removed after the (q)PCR reaction is performed. Pressure applied by the heated lid of the thermal cycler keeps the seal well closed during thermal cycling. -
Elastomeric Closures for Parenteral Applications
ROHSTOFFE UND ANWENDUNGEN RAW MATERIALS AND APPLICATIONS Parenterals . elastomeric closures . injection vials . infusion bottles . Elastomeric Closures for pre-fillable syringes Parenteral Applications Parenteral drug preparations are sterile preparations intended for administrati- on by injection, infusion or implantati- Parenteral closure types and designs plug diameter, flange thickness, total on into the human or animal body [1]. Parenteral drugs are administered by in- stopper height and penetration thick- Especially for injection and infusion ap- jection, infusion or implantation. The ness. The latter refers to the thickness of plications very often elastomeric closu- parenteral drug route is different from the rubber membrane that a small dia- res are used to guarantee the seal inte- e.g. the oral route or from the route of meter needle or a larger diameter hollow grity of the entire drug package. This inhalation. For injection and infusion ap- spike has to penetrate in order to get ac- article gives an insight into the required plications very often rubber closures are cess to the contents of the vials and eit- property profile of such closures. used to guarantee the integrity of the her inject a reconstitution medium or seal that is formed by the elastomeric withdraw the solution from the vials for closure and another component of the administration to the patient. Most of Elastomere Teile für Parenteralia total drug package. Since parenteral these dimensions are standardized in drugs are rendered sterile before they are corresponding standards issued by the Parenteralia . Elastomerdichtungen . put in the market, preservation of seal International Organization for Standar- Injektionsfläschchen . Infusionsfla- integrity by itself comes down to preser- dization [2]. -
Greenland Grapevine a Community Newsletter for the Town of Greenland, NH
Greenland Grapevine A Community Newsletter for the Town of Greenland, NH Vol. 8 Issue 2 Summer 2014 MEMORIAL DAY A Chance Meeting — Lifetime Memories IN GREENLAND By Glenn Bergeron Recently I had the extreme pleasure out she was headed to the small town of of talking with long-time Greenland Suippes, France, where the nurses were NH resident and WWII nurse veteran, to work in a make-shift general hospital Ruth Ladd. We discussed her nursing complex comprised of a series of large experiences in the war zone and espe- tents located behind the front lines. cially her surprise meeting with General George S. Patton, Jr. What follows is a It was here that Ruth encountered her heart-felt account of that meeting and first experience with the casualties of the events that led up to it. war. The amount and magnitude of It was July of 1944 and A parade, speeches, and music Ruth, along with her brought old and young alike together fellow nurses, had just at Remembrance Park on Memorial crossed the English Day. The solemn event was well Channel on a trans- attended as those who served in past port ship, which was and present wars were honored and now anchored off the remembered. For more scenes of the shore of Normandy, event, please turn to pages 10–11. France. They climbed aboard a Higgins landing craft (a small boat used to shuttle Sheila Pratt Selected as personnel from ship to shore that is made Citizen of the Year with a large front door By Barbara Fleming for a fast exit after At Town Meeting on Saturday, March at the school and in the community. -
Screw Cap Containers Screw Cap Screw Containers SCREW CAP CONTAINERS
Screw cap containers screw cap screw containers SCREW CAP CONTAINERS 18 Smipa - Made in plastic Screw cap containers ** Coloured supplies available. Gagi container Screw cap container + Container 100 ml 200 ml seal Art. 531 + 532 cop Art. 529 + 530 cop Art. 1463 + 1467 cop. screw cap screw containers Capacity: 100 ml Capacity: 200 ml Capacity: 200 ml Closure: screw cap Closure: screw cap Closure: screw with band Upper diam.: 55 mm Upper diam.: 65 mm Upper diam.: 65 mm Lower diam.: 50 mm Lower diam.: 58 mm Lower diam.: 58 mm Height: 53 mm Height: 80 mm Height: 80 mm Material: PP H Material: PP H Material: PP Weight: 11 g Weight: 21 g Packaging: 250 pieces box Packaging: 500 pieces box Packaging: 250 pieces box Screw cap container Screw cap container Glass container 200 ml 500 ml 1000 ml Art. 527 + 528 cop Art. 525 + 524 cop Art. 523 + 524 cop Capacity: 200 ml Capacity: 500 ml Capacity: 1000 ml Closure: screw cap Closure: screw cap Closure: screw cap Upper diam.: 85 mm Upper diam.: 105 mm Upper diam.: 105 mm Lower diam.: 80 mm Lower diam.: 98 mm Lower diam.: 98 mm Height: 55 mm Height: 75 mm Height: 145 mm Material: PE HD Material: PP H Material: PP H Weight: 23 g Weight: 36 g Weight: 70 g Packaging: 250 pieces box Packaging: 300 pieces box Packaging: 168 pieces box Smipa - Made in plastic 19 ** Coloured supplies available. Screw cap containers Screw cap container Screw cap container Screw cap container (formerly PS) 1000 ml 2000 ml 2000 ml Art. -
The Example of Closure Systems for Bottled Wine
Sustainability 2012, 4, 2673-2706; doi:10.3390/su4102673 OPEN ACCESS sustainability ISSN 2071-1050 www.mdpi.com/journal/sustainability Article The Importance of Considering Product Loss Rates in Life Cycle Assessment: The Example of Closure Systems for Bottled Wine Anna Kounina 1,2,*, Elisa Tatti 1, Sebastien Humbert 1, Richard Pfister 3, Amanda Pike 4, Jean-François Ménard 5, Yves Loerincik 1 and Olivier Jolliet 1 1 Quantis, Parc Scientifique EPFL, Bâtiment D, 1015 Lausanne, Switzerland; E-Mails: [email protected] (E.T.); [email protected] (S.H.); [email protected] (Y.L.); [email protected] (O.J.) 2 Swiss Federal Institute of Technology Lausanne (EPFL), 1015 Lausanne, Switzerland 3 Praxis Energia, rue Verte, 1261 Le Vaud, Switzerland; E-Mail: [email protected] 4 Quantis, 283 Franklin St. Floor 2, Boston, MA 02110, USA; E-Mail: [email protected] 5 Quantis, 395 rue Laurier Ouest, Montréal, Québec, H2V 2K3, Canada; E-Mail: [email protected] * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +41-21-693-91-95; Fax: +41-21-693-91-96. Received: 23 July 2012; in revised form: 21 September 2012 / Accepted: 2 October 2012 / Published: 18 October 2012 Abstract: Purpose: The objective of this study is to discuss the implications of product loss rates in terms of the environmental performance of bottled wine. Wine loss refers to loss occurring when the consumer does not consume the wine contained in the bottle and disposes of it because of taste alteration, which is caused by inadequate product protection rendering the wine unpalatable to a knowledgeable consumer. -
Alk Life Science Solutions™
ALK LIFE SCIENCE SOLUTIONS™ Catalog 2021 STERILE EMPTY VIALS (SEV) ITEM# VOLUME OUTER DIAMETER QUANTITY SEV213 2.0 cc 13 mm 100 SEV520 5.0 cc 20 mm 25 PRODUCT FEATURES *Available in Red, Green, Blue, and Silver Caps SEV1020 10 cc 20 mm 25 • USP Tested for Sterility *Available in Red, Green, Blue, and Silver Caps and Endotoxins SEV20 20 cc 20 mm 10 • Type 1 Glass USP SEV30 30 cc 20 mm 25 Borosilicate SEV50 50 cc 20 mm 25 SEV100 100 cc 20 mm 25 • cGMP FDA Manufacturer • Certificate of Analysis Available for All Production Lots • Latex Free Chlorobutyl Stopper • Aseptically Assembled in an ISO 5 (class 100) Cleanroom SEV213 SEV520 SEV1020S SEV30 SEV50 SEV100 2.0 cc 5.0 cc 10 cc 30 cc 50 cc 100 cc Assembled, Sterilized, and Tested in the USA AMBER STERILE EMPTY VIALS (SEV) ITEM# VOLUME OUTER DIAMETER QUANTITY SEV213S-AMB 2.0 cc 13 mm 100 PRODUCT FEATURES SEV520S-AMB 5.0 cc 20 mm 25 SEV1020S-AMB 10 cc 20 mm 25 • USP Tested for Sterility SEV30-AMB 30 cc 20 mm 25 and Endotoxins SEV50-AMB 50 cc 20 mm 25 SEV100-AMB 100 cc 20 mm 25 • Type 1 Glass USP Borosilicate • cGMP FDA Manufacturer • Certificate of Analysis Available for All Production Lots • Latex Free Chlorobutyl Stopper • Aseptically Assembled in an ISO 5 (class 100) Cleanroom SEV100-AMB SEV50-AMB SEV30-AMB SEV1020S-AMB SEV520-AMB SEV213-AMB 100 cc Amber 50 cc Amber 30 cc Amber 10 cc Amber 5.0 cc Amber 2.0 cc Amber Assembled, Sterilized, and Tested in the USA extra layer of security FLUROTEC® BARRIER ® FILM FluroTec ITEM DESCRIPTION Maintain drug purity and potency by choosing FluroTec® barrier film. -
Agilent 7890A GC Operating Guide
Agilent 7890A Gas Chromatograph Operating Guide Agilent Technologies Notices © Agilent Technologies, Inc. 2007-2010 Warranty Safety Notices No part of this manual may be reproduced The material contained in this docu- in any form or by any means (including ment is provided “as is,” and is sub- CAUTION electronic storage and retrieval or transla- ject to being changed, without notice, tion into a foreign language) without prior A CAUTION notice denotes a hazard. It agreement and written consent from Agi- in future editions. Further, to the max- calls attention to an operating lent Technologies, Inc. as governed by imum extent permitted by applicable United States and international copyright law, Agilent disclaims all warranties, procedure, practice, or the like that, if laws. either express or implied, with regard not correctly performed or adhered to, to this manual and any information could result in damage to the product Manual Part Number contained herein, including but not or loss of important data. Do not limited to the implied warranties of proceed beyond a CAUTION notice G3430-90011 merchantability and fitness for a par- until the indicated conditions are fully ticular purpose. Agilent shall not be understood and met. Edition liable for errors or for incidental or Third edition, June 2010 consequential damages in connection WARNING Second edition, September 2008 with the furnishing, use, or perfor- First edition, March 2007 mance of this document or of any A WARNING notice denotes a hazard. information contained herein. Should Printed in USA or China It calls attention to an operating Agilent and the user have a separate procedure, practice, or the like that, if Agilent Technologies, Inc. -
Mac Conkey Agar
TECHNICAL SHEET TS91098 Rev. 0 of 26.02.2007 Page 1 of 2 ________________________________________________________________________ OXI CONTROL E6 ALUMINIUM Biological indicators of H2O2 vapour superficial sterilization processes containing Geobacillus stearothermophilus (ATCC 7953) spores inoculated on aluminium coupons DESCRIPTION Biological indicators OXI CONTROL E6 ALMINIUM are produced under strictly controlled conditions in order to satisfy the requirements indicated in the USP and EP current editions and in accordance with ISO 11138 and EN 866 standards. These biological indicators use an aluminium support (coupon), that is not permeable to hydrogen peroxide. Aluminium coupon has been inoculated with Geobacillus stearothermophilus (ATCC 7953) spores and has been introduced into a Tyvek®/Polytene envelope. Each package contains a culture medium, STERI-TEST MEDIUM, in glass test tubes with screw cap closures. The medium is validated for use with coupons and meets the U.S. Pharmacoopoeia Revision XXII growth promotion guidelines. Each package contains also a Certificate of Performance that indicates a certified population , D-value (121°C), survival time, kill time, species, lot number and expiration date. COMPOSITION Coupons contain Geobacillus stearothermophilus (ATCC 7953) spores in concentration:1-5 x106CFU/coupon. Each coupon is contained in an envelope. Each envelope is printed with product name, lot number and expiration date. STERI-TEST MEDIUM is a sterile modified soybean casein digest broth with a pH indicator. Each tube is printed with product name, lot number and expiration date. PRINCIPLE Spores are completely killed if the sterilization cycle has been efficient . In this case, during the following incubation in the Steri-Test Medium tubes, included in the package, spores are not able to grow and to modify medium’s aspect. -
SCHOTT DURAN® Laboratory Glass Bottles and Screw Caps - Rely on the Original! - 50086 E 0105 6.5 Ba/Jo Printed in Germany
04194_Sprache_E_RZ.fh8 24.01.2005 14:31 Uhr Seite 2 LABWARE SCHOTT DURAN® E SCHOTT DURAN® laboratory glass bottles and screw caps - Rely on the original! - 50086 e 0105 6.5 ba/jo Printed in Germany Labware SCHOTT AG Hattenbergstrasse 10 55122 Mainz Germany Phone: +49 (0)6131/664907 Fax: +49 (0)6131/664016 E-mail: [email protected] www.schott.com/duran 04194_Sprache_E_RZ.fh8 24.01.2005 14:31 Uhr Seite 3 SCHOTT DURAN® laboratory glass bottles Fields of application and properties The outstanding properties of DURAN® laboratory glass bottles have been valued for many years. By continuous development and improvement, SCHOTT is able to provide top-quality products and systems based on the original, well proven bottle design. Their consistency, reliability and flexibility in storage, packaging and preparation applications make DURAN® laboratory glass bottles the global standard for the chemical, pharmaceutical and bioscience fields. ■ conformity with ISO standards 3585 and 4796 ■ glass type No. 1, normal glass pursuant to USP 27; EP; DAB 10 ■ high service temperature of up to 500°C ■ excellent thermal shock resistance ■ easy to clean and readily sterilized ■ excellent chemical resistance ■ highly inert ■ standardized GL screw thread and matching screw cap systems ensure a low-leakage closure with excellent pouring capabilities ■ stable design and uniform wall strength make DURAN® laboratory glass bottles robust helpers in daily work even under high mechanical strain and rapid or extreme changes in temperature ■ all DURAN® laboratory glass bottles are now supplied with a printed “Retrace Code” allowing batch and quality certification via the internet NEW 04194_Sprache_E_RZ.fh8 24.01.2005 14:31 Uhr Seite 4 A perfect solution to each and every application The classic version – the DURAN® laboratory glass bottle The original is widely used in labora- tories and factories in numerous applications. -
Laboratory Supplies and Equipment
Laboratory Supplies and Equipment Beakers: 9 - 12 • Beakers with Handles • Printed Square Ratio Beakers • Griffin Style Molded Beakers • Tapered PP, PMP & PTFE Beakers • Heatable PTFE Beakers Bottles: 17 - 32 • Plastic Laboratory Bottles • Rectangular & Square Bottles Heatable PTFE Beakers Page 12 • Tamper Evident Plastic Bottles • Concertina Collapsible Bottle • Plastic Dispensing Bottles NEW Straight-Side Containers • Plastic Wash Bottles PETE with White PP Closures • PTFE Bottle Pourers Page 39 Containers: 38 - 42 • Screw Cap Plastic Jars & Containers • Snap Cap Plastic Jars & Containers • Hinged Lid Plastic Containers • Dispensing Plastic Containers • Graduated Plastic Containers • Disposable Plastic Containers Cylinders: 45 - 48 • Clear Plastic Cylinder, PMP • Translucent Plastic Cylinder, PP • Short Form Plastic Cylinder, PP • Four Liter Plastic Cylinder, PP NEW Polycarbonate Graduated Bottles with PP Closures Page 21 • Certified Plastic Cylinder, PMP • Hydrometer Jar, PP • Conical Shape Plastic Cylinder, PP Disposal Boxes: 54 - 55 • Bio-bin Waste Disposal Containers • Glass Disposal Boxes • Burn-upTM Bins • Plastic Recycling Boxes • Non-Hazardous Disposal Boxes Printed Cylinders Page 47 Drying Racks: 55 - 56 • Kartell Plastic Drying Rack, High Impact PS • Dynalon Mega-Peg Plastic Drying Rack • Azlon Epoxy Coated Drying Rack • Plastic Draining Baskets • Custom Size Drying Racks Available Burn-upTM Bins Page 54 Dynalon® Labware Table of Contents and Introduction ® Dynalon Labware, a leading wholesaler of plastic lab supplies throughout -
Xstamper Industrial F06, F11, and F30 Refill Instructions
A3_33096 2004.03.15 19:32 ページ 1 5. After refilling ink, replace plug and replace die holder to handle with die side up. For F06, F11 and F30 Replace cap back on firmly. Fig.6 6. Leave stamp for 30 minutes vertically with impression die face down and test Fast Dry Stamp for Non-porous Surfaces impression by stamping before actual use. Handling and Re-inking Instructions Impression cap F30 Please read these instructions carefully before use and keep in safe place for future reference. 1. Screw off cap and hold handle vertically. Use bottom-side of cap to remove die holder. Insert bottom of cap to die holder and turn handle counter-clockwise Fig.7 k n i efill This product is specially formulated with quick dry ink which is ideal for repetitive stamping on non-porous surfaces such as towards 'open' to remove die holder. (Fig. 6) Backer pad R Die holder metal, plastic, glass, cloth, leather and coated paper. No stamp pad is required! Once completely dry, the impression is resistant • If you hold die holder horizontally, backer pad may fall out. Impression cap to water and heat. (Performance may vary depending on surface stamped.) The rubber die is designed to be durable and • Note: Make sure your hands don't come in contact with ink when removing die chemical resistant, making it the stamp of choice in harsh manufacturing environments. holder. 2. Place recommended number of drops of ink into opening so ink is spread evenly Fig.8 Usage & Storage Instructions onto backer pad. (Fig.