Arxiv:1512.05503V4 [Physics.Plasm-Ph] 14 Mar 2016
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Mass Spectrometry: Quadrupole Mass Filter
Advanced Lab, Jan. 2008 Mass Spectrometry: Quadrupole Mass Filter The mass spectrometer is essentially an instrument which can be used to measure the mass, or more correctly the mass/charge ratio, of ionized atoms or other electrically charged particles. Mass spectrometers are now used in physics, geology, chemistry, biology and medicine to determine compositions, to measure isotopic ratios, for detecting leaks in vacuum systems, and in homeland security. Mass Spectrometer Designs The first mass spectrographs were invented almost 100 years ago, by A.J. Dempster, F.W. Aston and others, and have therefore been in continuous development over a very long period. However the principle of using electric and magnetic fields to accelerate and establish the trajectories of ions inside the spectrometer according to their mass/charge ratio is common to all the different designs. The following description of Dempster’s original mass spectrograph is a simple illustration of these physical principles: The magnetic sector spectrograph PUMP F DD S S3 1 r S2 Fig. 1: Dempster’s Mass Spectrograph (1918). Atoms/molecules are first ionized by electrons emitted from the hot filament (F) and then accelerated towards the entrance slit (S1). The ions then follow a semicircular trajectory established by the Lorentz force in a uniform magnetic field. The radius of the trajectory, r, is defined by three slits (S1, S2, and S3). Ions with this selected trajectory are then detected by the detector D. How the magnetic sector mass spectrograph works: Equating the Lorentz force with the centripetal force gives: qvB = mv2/r (1) where q is the charge on the ion (usually +e), B the magnetic field, m is the mass of the ion and r the radius of the ion trajectory. -
Orbitrap Fusion Tribrid Mass Spectrometer
MASS SPECTROMETRY Product Specifications Thermo Scientific Orbitrap Fusion Tribrid Mass Spectrometer Unmatched analytical performance, revolutionary MS architecture The Thermo Scientific™ Orbitrap Fusion™ mass spectrometer combines the best of quadrupole, Orbitrap, and linear ion trap mass analysis in a revolutionary Thermo Scientific™ Tribrid™ architecture that delivers unprecedented depth of analysis. It enables life scientists working with even the most challenging samples—samples of low abundance, high complexity, or difficult-to-analyze chemical structure—to identify more compounds faster, quantify them more accurately, and elucidate molecular composition more thoroughly. • Tribrid architecture combines quadrupole, followed by ETD or EThCD for glycopeptide linear ion trap, and Orbitrap mass analyzers characterization or HCD followed by CID • Multiple fragmentation techniques—CID, for small-molecule structural analysis. HCD, and optional ETD and EThCD—are available at any stage of MSn, with The ultrahigh resolution of the Orbitrap mass subsequent mass analysis in either the ion analyzer increases certainty of analytical trap or Orbitrap mass analyzer results, enabling molecular-weight • Parallelization of MS and MSn acquisition determination for intact proteins and confident to maximize the amount of high-quality resolution of isobaric species. The unsurpassed data acquired scan rate and resolution of the system are • Next-generation ion sources and ion especially useful when dealing with complex optics increase system ease of operation and robustness and low-abundance samples in proteomics, • Innovative instrument control software metabolomics, glycomics, lipidomics, and makes setup easier, methods more similar applications. powerful, and operation more intuitive The intuitive user interface of the tune editor The Orbitrap Fusion Tribrid MS can perform and method editor makes instrument calibration a wide variety of analyses, from in-depth and method development easier. -
Electrification Ionization: Fundamentals and Applications
Louisiana State University LSU Digital Commons LSU Doctoral Dissertations Graduate School 11-12-2019 Electrification Ionization: undamentalsF and Applications Bijay Kumar Banstola Louisiana State University and Agricultural and Mechanical College Follow this and additional works at: https://digitalcommons.lsu.edu/gradschool_dissertations Part of the Analytical Chemistry Commons Recommended Citation Banstola, Bijay Kumar, "Electrification Ionization: undamentalsF and Applications" (2019). LSU Doctoral Dissertations. 5103. https://digitalcommons.lsu.edu/gradschool_dissertations/5103 This Dissertation is brought to you for free and open access by the Graduate School at LSU Digital Commons. It has been accepted for inclusion in LSU Doctoral Dissertations by an authorized graduate school editor of LSU Digital Commons. For more information, please [email protected]. ELECTRIFICATION IONIZATION: FUNDAMENTALS AND APPLICATIONS A Dissertation Submitted to the Graduate Faculty of the Louisiana State University and Agricultural and Mechanical College in partial fulfillment of the requirements for the degree of Doctor of Philosophy in The Department of Chemistry by Bijay Kumar Banstola B. Sc., Northwestern State University of Louisiana, 2011 December 2019 This dissertation is dedicated to my parents: Tikaram and Shova Banstola my wife: Laxmi Kandel ii ACKNOWLEDGEMENTS I thank my advisor Professor Kermit K. Murray, for his continuous support and guidance throughout my Ph.D. program. Without his unwavering guidance and continuous help and encouragement, I could not have completed this program. I am also thankful to my committee members, Professor Isiah M. Warner, Professor Kenneth Lopata, and Professor Shengli Chen. I thank Dr. Fabrizio Donnarumma for his assistance and valuable insights to overcome the hurdles throughout my program. I appreciate Miss Connie David and Dr. -
A Researcher's Guide to Mass Spectrometry‐Based Proteomics
Proteomics 2016, 16, 2435–2443 DOI 10.1002/pmic.201600113 2435 TUTORIAL A researcher’s guide to mass spectrometry-based proteomics John P. Savaryn1,2∗, Timothy K. Toby3∗ and Neil L. Kelleher1,3,4 1 Proteomics Center of Excellence, Northwestern University, Evanston, Illinois, USA 2 Comprehensive Transplant Center, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA 3 Department of Molecular Biosciences, Northwestern University, Evanston, Illinois, USA 4 Department of Chemistry, Northwestern University, Evanston, Illinois, USA Mass spectrometry (MS) is widely recognized as a powerful analytical tool for molecular re- Received: February 24, 2016 search. MS is used by researchers around the globe to identify, quantify, and characterize Revised: May 18, 2016 biomolecules like proteins from any number of biological conditions or sample types. As Accepted: July 8, 2016 instrumentation has advanced, and with the coupling of liquid chromatography (LC) for high- throughput LC-MS/MS, a proteomics experiment measuring hundreds to thousands of pro- teins/protein groups is now commonplace. While expert practitioners who best understand the operation of LC-MS systems tend to have strong backgrounds in physics and engineering, consumers of proteomics data and technology are not exposed to the physio-chemical principles underlying the information they seek. Since articles and reviews tend not to focus on bridging this divide, our goal here is to span this gap and translate MS ion physics into language intuitive to the general reader active in basic or applied biomedical research. Here, we visually describe what happens to ions as they enter and move around inside a mass spectrometer. We describe basic MS principles, including electric current, ion optics, ion traps, quadrupole mass filters, and Orbitrap FT-analyzers. -
Quadrupole and Ion Trap Mass Analysers and an Introduction to Resolution a Simple Definition of a Mass Spectrometer
Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution A simple definition of a Mass Spectrometer ◗ A Mass Spectrometer is an analytical instrument that can separate charged molecules according to their mass–to–charge ratio. The mass spectrometer can answer the questions “what is in the sample” (qualitative structural information) and “how much is present” (quantitative determination) for a very wide range of samples at high sensitivity Components of a Mass Spectrometer Atmosphere Vacuum System Sample Ionisation Mass Data Detector Inlet Method Analyser System How are mass spectra produced ? ◗ Ions are produced in the source and are transferred into the mass analyser ◗ They are separated according to their mass/charge ratio in the mass analyser (e.g. Quadrupole, Ion Trap) ◗ Ions of the various m/z values exit the analyser and are ‘counted’ by the detector What is a Mass Spectrum ? ◗ A mass spectrum is the relative abundance of ions of different m/z produced in an ion source -a “chemical fingerprint” ◗ It contains – Molecular weight information (generally) – Structural Information (mostly) – Quantitative information What does a mass spectrum look like ? ◗ Electrospray mass spectrum of salbutamol + 100 MH 240 OH NH tBu HO Base peak HO % at m/z 240 241 0 60 80 100 120 140 160 180 200 220 240 260 280 300 What information do you need from the analysis ? ◗ Low or High Mass range ◗ Average or Monoisotopic mass (empirical) ◗ Accurate Mass ◗ Quantitation - precision, accuracy, selectivity ◗ Identification ◗ Structural Information -
Specification Sheet: LTQ XL Linear Ion Trap Mass Spectrometer
PRODUCT SPECIFICATIONS The Thermo Scientific™ LTQ XL™ linear ion trap mass spectrometer Everyday affordability with MSn The LTQ XL linear ion trap mass spectrometer delivers high sensitivity full Keywords scan MS along with in-depth MSn (CRM) capabilities. LTQ XL linear ion trap mass If you are in the market for an extremely affordable general-purpose mass n spectrometer, MS (CRM) spectrometer, look no further than the LTQ XL. capabilities, proteomics, metabolite identification, forensic analysis, Applications include proteomics, metabolite identification, forensic analysis, clinical research, teaching clinical research and teaching. General purpose utility extends to users in academia, industry and government alike. Now includes updated software with Windows 10 compatibility enabling full support today and into the future A single quadrupole offers no more than Selected Ion Monitoring (SIM). A triple quadrupole adds Selected Reaction Monitoring (SRM) where a selected ion can be fragmented into a product ion. A linear ion trap goes further by enabling Consecutive Reaction Monitoring (CRM) where a selected ion is fragmented into a product ion and the resulting product ion further fragmented in additional consecutive steps (MSn). Each additional fragmentation step makes compound identification more certain and facilitates structural characterization. Selected Ion First Product Ion Second Product Ion (MS1) Fragmentation (MS2) Fragmentation (MS3) Powerful tools for structural characterization Collision Induced Dissociation (CID) • Resonance -
Optimized DLP Linear Ion Trap for a Portable Non-Scanning Mass Spectrometer
International Journal of Mass Spectrometry 369 (2014) 30–35 Contents lists available at ScienceDirect International Journal of Mass Spectrometry journa l homepage: www.elsevier.com/locate/ijms Optimized DLP linear ion trap for a portable non-scanning mass spectrometer a, a b c Boris Brkic *, Stamatios Giannoukos , Neil France , Robert Murcott , d a Fabrizio Siviero , Stephen Taylor a Department of Electrical Engineering and Electronics, University of Liverpool, Brownlow Hill, Liverpool L69 3GJ, United Kingdom b Q Technologies Ltd, 100 Childwall Road, Liverpool L15 6UX, United Kingdom c TWI Technology Centre Yorkshire, Advanced Manufacturing Park, Wallis Way, Catcliffe, Rotherham S60 5TZ, United Kingdom d Vacuum Technology Lab, SAES Getters S.p.A., Viale Italia 77, Lainate 20020, Milan, Italy A R T I C L E I N F O A B S T R A C T Article history: This work reports implementation of an optimized linear ion trap (LIT) mass analyzer manufactured Received 7 April 2014 using digital light processing (DLP), a low cost rapid prototyping technique. To satisfy requirements for a Received in revised form 23 May 2014 portable commercial instrument, our previous DLP LIT has been improved by using polymer material for Accepted 2 June 2014 electrodes and housing with higher heat deflection temperature and much improved metal coating of the Available online 4 June 2014 electrodes. In this way, a polymer-based LIT can operate at higher pressures with more stable voltages, low outgassing and with much longer electrode lifetime. This paper demonstrates non-scanning Keywords: operation of a DLP LIT based on ceramic resin with specially electroplated electrodes. -
Investigations on Dynamical Stability in 3D Quadrupole Ion Traps
applied sciences Article Investigations on Dynamical Stability in 3D Quadrupole Ion Traps Bogdan M. Mihalcea 1,* and Stephen Lynch 2 1 National Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomi¸stilorStr. Nr. 409, 077125 M˘agurele, Romania 2 Department of Computing and Mathematics, Manchester Metropolitan University, Manchester M1 5GD, UK; [email protected] * Correspondence: bogdan.mihalcea@inflpr.ro; Tel.: +40-21-4574437 Abstract: We firstly discuss classical stability for a dynamical system of two ions levitated in a 3D Radio-Frequency (RF) trap, assimilated with two coupled oscillators. We obtain the solutions of the coupled system of equations that characterizes the associated dynamics. In addition, we supply the modes of oscillation and demonstrate the weak coupling condition is inappropriate in practice, while for collective modes of motion (and strong coupling) only a peak of the mass can be detected. Phase portraits and power spectra are employed to illustrate how the trajectory executes quasiperiodic motion on the surface of torus, namely a Kolmogorov–Arnold–Moser (KAM) torus. In an attempt to better describe dynamical stability of the system, we introduce a model that characterizes dynamical stability and the critical points based on the Hessian matrix approach. The model is then applied to investigate quantum dynamics for many-body systems consisting of identical ions, levitated in 2D and 3D ion traps. Finally, the same model is applied to the case of a combined 3D Quadrupole Ion Trap (QIT) with axial symmetry, for which we obtain the associated Hamilton function. The ion distribution can be described by means of numerical modeling, based on the Hamilton function Citation: Mihalcea, B.M.; Lynch, S. -
CHAPTER 5 Mass Spectrometry, Cont'd Part 2
CHAPTER 5 Mass Spectrometry, Cont’d Part 2 5.2.6.3 Quadrupole ion trap mass filter: While the operation of the ion trap was characterized shortly after the linear quadrupole in 1960 by Paul and Steinwedel, its application in the chemical laboratory was severely limited. This was due to difficulties associated with manufacturing a circular electrode and performance problems. These performance problems were overcome when a group at Finnigan MAT lead by Stafford discovered two breakthroughs that lead to the production of a commercially available ion trap mass filter. The first ion trap developed used a mode of operation where a single mass could be stored in the trap when previously all of the ions had to be stored. Their next important discovery was the ability for 1 mtorr of helium gas to improve the instruments resolution. The helium molecules’ collisions with the ions reduced their kinetic energy and subsequently focused them towards the center of the trap. After these initial hurdles were cleared, many new techniques were developed for a diverse set of applications especially in biochemistry. This is a result of its comparative advantage over the quadrupole when analyzing high molecular mass compounds (up to several thousand m/z units) to unit resolution in commonly encountered instruments. The ion trap is also an extremely sensitive instrument that allows a molecular weight to be determined with a small number of molecules. The ion trap is also the only mass filter that can contain ions that need to be analyzed for any significant duration of time. This allows the instrument to be particularly useful in monitoring the kinetics of a given reaction. -
Mass Analyzers Ion Movement
Mass Analyzers Árpád Somogyi CCIC MSP OSU Summer Workshop Ion movement • Biased metal plates (electrodes, lenses) used to move ions between ion source and analyzers • Electrodes and physical slits used to shape and restrict ion beam • Good sensitivity is dependent on good ion transmittance efficiency in this area Ionization Mass Detector source analyzer inlet all ions sorted Data ions system 1 Ion detection • Ions can be detected efficiently w/ high amplification by accelerating them into surfaces that eject electrons Ionization Mass Detector source analyzer inlet all ions sorted Data ions system Detectors TOF 2 Ion energy • Kinetic energy of ions defined by E = zeV = qV = ½ mv2 E = kinetic energy m = mass v = velocity e = electronic charge (1.60217e-19 C) z = nominal charge V = accelerating voltage Learning Check Consider two electrodes, one at 1000 V and one at ground (0 V) 1000 V0 V + ion will travel with kinetic energy of ___________ 3 Question: Consider an ion source block and an extraction lens. How would you bias the block and lens if you want the ions to be accelerated by a) 8000 eV (appropriate for magnetic sector) b) 5 eV (appropriate for entering a quadrupole) c) 20,000 eV (appropriate for entering a TOF) Notice: accelerating voltages vary with analyzer (has consequences for MS/MS) • High voltage (keV energy range) – magnet (B) – electrostatic (E) – time-of-flight (TOF) • Low voltage (eV energy range) – quadrupole (Q) – ion trap (IT, LT, OT) – ion cyclotron resonance (ICR) 4 Mass Resolution • Mass spectrometers separate ions with a defined resolution/resolving power • Resolving power- the ability of a mass spectrometer to separate ions with different mass to charge (m/z) ratios. -
Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Brigham Young University
Brigham Young University BYU ScholarsArchive All Theses and Dissertations 2017-08-01 Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Brigham Young University Follow this and additional works at: https://scholarsarchive.byu.edu/etd Part of the Chemistry Commons BYU ScholarsArchive Citation Li, Ailin, "Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer" (2017). All Theses and Dissertations. 6503. https://scholarsarchive.byu.edu/etd/6503 This Dissertation is brought to you for free and open access by BYU ScholarsArchive. It has been accepted for inclusion in All Theses and Dissertations by an authorized administrator of BYU ScholarsArchive. For more information, please contact [email protected], [email protected]. Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li A dissertation submitted to the faculty of Brigham Young University in partial fulfillment of the requirements for the degree of Doctor of Philosophy Daniel E. Austin, Chair Matthew C. Asplund David V. Dearden Steven R. Goates Jaron C. Hansen Department of Chemistry and Biochemistry Brigham Young University Copyright © 2017 Ailin Li All Rights Reserved ABSTRACT Miniaturization of Linear Ion Traps and Ion Motion Study in a Toroidal Ion Trap Mass Analyzer Ailin Li Department of Chemistry and Biochemistry, BYU Doctor of Philosophy I describe the miniaturization of a linear-type ion trap mass spectrometer for possible applications in portable chemical analysis, and demonstrate the advantages of using lithographically patterned electrode plates in realizing an ion trap with dimension r0 less than 1 mm. -
Transport of Trapped-Ion Qubits Within a Scalable Quantum Processor
Transport of Trapped-Ion Qubits within a Scalable Quantum Processor by R. Bradford Blakestad B.S., California Institute of Technology, 2002 A thesis submitted to the Faculty of the Graduate School of the University of Colorado in partial fulfillment of the requirements for the degree of Doctor of Philosophy Department of Physics 2010 This thesis entitled: Transport of Trapped-Ion Qubits within a Scalable Quantum Processor written by R. Bradford Blakestad has been approved for the Department of Physics Dr. David J. Wineland Prof. Murray J. Holland Date The final copy of this thesis has been examined by the signatories, and we find that both the content and the form meet acceptable presentation standards of scholarly work in the above mentioned discipline. iii Blakestad, R. Bradford (Ph.D., Physics) Transport of Trapped-Ion Qubits within a Scalable Quantum Processor Thesis directed by Dr. David J. Wineland Key requirements for efficient large-scale quantum computing (QC) include reliable transport of information throughout the processor and the ability to perform gates between arbitrarily selected qubits. Trapped ions are a useful system for studying the elements of QC and can potentially satisfy these requirements. The internal atomic state of the ion can be used as a qubit. Quantum gate operations can be performed with electromagnetic fields and entangling operations are achieved by using those fields to map information between the qubits and a shared motional mode of the trapped ions. One approach to extending this to large-scale QC would be to distribute ions over separate zones in an array, where information would be shared between zones by physically transporting the ions.