Fire Station Specs
Total Page:16
File Type:pdf, Size:1020Kb
SPECIFICATIONS PAGE 1 OF 4 TABLE OF CONTENTS _________________________________________________________________________ ARCHITECTURAL SPECIFICATIONS: SUMMARY OF WORK DIVISION 1 – GENERAL REQUIREMENTS: 0120 Job Organization 0125 Samples and Shop Drawings 0130-2 Temporary Construction Facilities 0150 Cleaning Up and Damages 0190-2 Prevention of Architectural Barriers to Handicapped Adult DIVISION 2 – SITE WORK: 0201 Subsurface Investigation 0210 Modernization 0225 Termite Protection 0279 Fine Grading and Top Soil 0294 Prefinished Metal Privacy Fence, Gates & Operators DIVISION 4 – MASONRY: 0410 Masonry and Accessories DIVISION 5 – METALS: 0550 Miscellaneous Metals 0570 Expansion Joint Covers DIVISION 6 – WOOD AND PLASTICS: 0616 Wood Construction 0623-2 Millwork and Interior Wood Doors 0631-3 Composite Solid Counters, Sills & Shower Walls DIVISION 7 – THERMAL AND MOISTURE PROTECTION: 0717 Waterproofing and Dampproofing 0719 Caulking and Sealant 0720-2 Thermal Insulation 0735 Polyurethane Spray Insulation 0753-3 Preformed Metal Roof & Soffit/Ceiling Panels 0760 Sheet Metal 0793 F.R.P. Wall Panels DIVISION 8 – DOORS, WINDOWS AND GLASS: 0809-4 Aluminum Frame Doors and Windows 0810 Hollow Metal Doors and Frames 0821-2 Glass Block System SPECIFICATIONS PAGE 2 OF 4 TABLE OF CONTENTS _________________________________________________________________________ 0826 Ceiling Access Panels 0870 Finish Hardware 0887 Glass and Glazing DIVISION 9 – FINISHES: 0919 Exterior Insulation & Finish System 0920 Gypsum Board Drywall System 0930 Ceramic Tile Floors & Base 0934 Resilient Athletic Flooring - Impact 0961 Acoustical Sound Panels 0972 Vinyl Base, Nosings and Accessories 0973 LVT Tile Flooring 0988 Special Concrete Floor Finished 0990 Painting DIVISION 10 – SPECIALTIES: 1028-2 Flag Pole 1034 Over-Head Doors (Base Bid) 1040-2 Bi-fold Apparatus Doors (Add Alternate No. 2) 1040-3 Hi-Speed Apparatus Doors (Add Alternate No. 3) 1043 Interior Room Signs Allowance 1045 Building Plaque 1051 Gear Lockers 1080 Toilet Room Accessories 1084 Shower Doors 1095 Fire Extinguishers DIVISION 11 – EQUIPMENT: 1140 Stainless Steel Equipment 1145-2 Owner Furnished Equipment DIVISION 12 – FURNISHING: 1207-2 Carpet Tiles 1216 Window Blinds CIVIL SITE WORK SPECIFICATIONS: 01 42 19 Reference Standards 31 11 00 Clearing & Grubbing 31 14 13 Soil Striping & Stockpiling 31 22 16 Site Preparation 31 23 16 Excavation & Fill 31 50 10 Trench Safety Systems SPECIFICATIONS PAGE 3 OF 4 TABLE OF CONTENTS _________________________________________________________________________ STRUCTURAL SPECIFICATIONS: 00210 Soil Investigation Data 01151 Unit Prices 01410 Testing Laboratory Services 02100 Clearing 02215 Excavation 02220 Backfilling 02362 Drilled Pier Foundations 03001 Formwork 03150 Expansion Joints 03200 Reinforcing 03300 Cast-In–Place Concrete 03350 Finishing and Curing Concrete 05120 Structural Steel 06100 Rough Carpentry 06180 Glue-Laminated Structural Units 06192 Fabricated Wood Trusses M.P.E. SPECIFICATIONS: 15000 General Provisions for Mechanical 15010 Submittals and Shop Drawings 15100 Site Utilities 15110 Natural Gas Systems 15140 Hangers and Supports 15190 Mechanical Identification 15260 Piping Insulation 15270 Duct Insulation 15300 Fire Protection Systems 15310 Fire Protection Piping 15410 Plumbing Piping 15430 Plumbing Specialties 15440 Plumbing Fixtures 15800 HVAC General Provisions 15840 Ductwork 15850 Heating, Ventilation and Air Conditioning Equipment 15990 Testing, Adjusting and Balancing 16000 General Provisions for Electrical 16010 Submittals and Shop Drawings 16110 Conduit 16120 Building Wire and Cable 16130 Boxes 16140 Wiring Devices SPECIFICATIONS PAGE 4 OF 4 TABLE OF CONTENTS _________________________________________________________________________ 16160 Circuit and Motor Disconnects 16170 Grounding and Bonding 16190 Supporting Devices 16195 Electrical Identification 16420 Utility Service Entrance 16470 Panelboards 16510 Luminaries 16720 Fire Alarm 16780 Communications and Computer Systems 16785 COSA Systems Wiring Standards 2009 International Energy Conservation Code Certificates ARCHITECTURAL SPECIFICATIONS DIVISION 1 GENERAL PAGE 1 OF 3 SUMMARY OF WORK ____________________________________________________________________________ GENERAL: 1. Site of the project is located at 3415 Edgewood Dr., San Angelo, Texas at the corner of S. Chadbourne St. (Farm to Market 1223) & Edgewood Dr. 2. Before submitting a bid for this work, each Bidder is responsible for having examined the site and is aware of existing conditions under which he will operate and could in any manner affect the work under this Contract. No allowance will be made subsequently in this connection to Contractor for error or negligence on his part, or slight discrepancies in Drawings. SCOPE OF WORK: The City of San Angelo will be seeking sealed proposals for the construction of one (1) new station for the San Angelo Fire Department. Fire Station No. 4 contains 11,100 sq. ft. and is located on new property obtained by the City of San Angelo. All Contractors, regardless of proposal submitted, shall be subject to submissions criteria set forth by the City of San Angelo in accompanying sections in the bid documents. CHANGE ORDERS: General Contractor shall include all documentation necessary to complete a change order and/or change order request including but not limited to cost invoices for materials and labor (where applicable), subcontractor invoices etc. General Contractor’s overhead and profit multipliers as set forth in the contract shall be calculated and included in the change order. Note: Subcontractors (and suppliers where applicable) shall agree to an overhead and profit multiplier not to exceed that as set forth in the contract for the General Contractor. CONSTRUCTION CONTINGENCY TO PROPOSAL OR QUOTE: General Contractor shall include in his bid as part of the Base Proposal a construction contingency of $150,000 to cover contingencies. No work shall be implemented under this allowance except at the instruction of the Architect or the Owner. Any unused balance of this allowance shall be deducted from the final payment to the General Contractor. DIVISION 1 GENERAL PAGE 2 OF 3 SUMMARY OF WORK ____________________________________________________________________________ Note that the General Contractor’s profit and overhead for the items drawn from the contingency shall be included in the Base Bid itself and not part of the above contingency fund. Copies of labor time sheets and materials invoices shall be submitted with request for payment for additional work from this contingency. CASH ALLOWANCES SCHEDULE: Cash allowances shall be incorporated into the bids submitted by each relevant Subcontractor to the General Contractor for inclusion into the Base Bid. Allowance shall cover all expense necessary to the Owner. General Contractor’s profit and overhead shall be included in the bid itself and not considered a part of the allowance expense. Landscaping - $20,000 Interior Room Signs - $200 Face Brick Veneer - $600 per thousand DESCRIPTION OF ALTERNATES: Add Alternate No. 1: Furnish & install new 30'-0" wide driveway section that connects north parking lot with west parking lot. Refer to Partial Site Plan drawing C/A-1 for detailed info. Add Alternate No. 2: Furnish & install (3) three 14' x 14' automatic "Bi-folding" apparatus doors (as per spec. section 1040-2) located on east side of engine bay in lieu of (base bid) standard type overhead sectional doors (as per spec. section 1034). Add Alternate No. 3: Furnish & install (3) three 14' x 14' automatic "High-Speed" apparatus doors (as per spec. section 1040-3) located on east side of engine bay in lieu of (base bid) standard type overhead sectional doors (as per spec. section 1034). Add Alternate No. 4: Furnish & install (5) five "AirVac" recirculation systems to filter the engine bay exhaust. Refer to drawing sheet M-2 for specifications. DIVISION 1 GENERAL PAGE 3 OF 3 SUMMARY OF WORK ____________________________________________________________________________ UNIT PRICING: Bidders shall provide the following concrete foundation unit pricing for the Owner in the event that footage is either to be added or deleted. Refer to Specification Section 01151 for additional info. Note that these unit costs shall be included on the project's bid proposal form. 1. Unit price for 18" diameter drilled pier casing per lin/ft. 2. Unit price for 24" diameter drilled pier casing per lin/ft. 3. Unit price for 30" diameter drilled pier casing per lin/ft. DIVISION 1 GENERAL REQUIREMENTS SECTION 0120 JOB ORGANIZATION PAGE 1 OF 3 _____________________________________________________________________________ GENERAL: A.I.A. General and Supplementary Conditions govern work of this Section. USE OF PREMISES: 1. Owner retains the right at all times to deliver, place, and install furnishings, equipment, etc., as work progresses where there is no interference with the Contractor. Such preliminary occupancy shall not be construed as acceptance of such portions of the building. 2. Adjacent Property: Under no circumstances will any persons connected with this contract use any adjacent property outside project limits for purpose of parking, fabricating, or storing materials. PROTECTION: 1. General Contractor shall protect all existing streets, walks, curbs, fences, landscaping, etc., make all necessary repairs at his own expense, and maintain them during the course of the work. 2. General Contractor shall, before starting work, erect such protections and barricades around site