DIAGNOSTIC MEDICAL SONOGRAPHY STUDENT PROGRAM HANDBOOK Policies and Procedures

Total Page:16

File Type:pdf, Size:1020Kb

DIAGNOSTIC MEDICAL SONOGRAPHY STUDENT PROGRAM HANDBOOK Policies and Procedures DIAGNOSTIC MEDICAL SONOGRAPHY STUDENT PROGRAM HANDBOOK Policies and Procedures Coordinate With: DMS Clinical Evaluation Handbook & DMS Clinical Experience Forms Revised 11/13; 7/ 2015; 11/2016; 11/2018, 12/20 i Order of Contents Overview Projected Class Schedule I. Introduction II. Accreditation III. Attendance IV. Scholarship Criteria & Information V. Student Rights and Grievances (Administrative Procedure 5530) VI. Records VII. Financial Expenditures VIII. General Policies IX. Insurance, Accidents, and Incidents X. Clinical Assignments XI. Student Dress and Grooming for Clinical Education XII. Student Orientation to Clinical Facilities XIII. Clinical Experience XIV. Clinical Radiation Protection Rules XV. Pregnancy Policy and Procedures XVI. Student Supervision XVII. Personnel Descriptions XVIII. Professionalism, Job Description XIX. Patient Safety and Risk Management XXI. Equipment Safety and Maintenance XXII. Technical Protocols XXII. Ergonomics XVIII. Appendices A. Academic Honesty Procedure B. Conduct Code Violations C. COVID-19 ii iii Overview of the Diagnostic Medical Sonography Program The Sonography Program is a full-time, allied vocational health program located in the agricultural community of Merced, California. Here, from the Allied Health Parking lot at Merced College, is our nearest clinical affiliate, Dignity Health Mercy Hospital. The purpose of the program is to provide didactic education and practical experience as preparation for employment as an entry-level sonographer in a medical imaging facility. The program is divided into two components: (a) didactic with laboratory, and (b) clinical education. Graduates of the program are awarded a Certificate of Achievement in Diagnostic Medical Sonography, and are eligible to sit for the SPI, ABD, and OB-GYN American Registry for Diagnostic Medical Sonography board examinations. The didactic portion of the program facilitates learning in “General Sonography,” with a focus on the following areas: Abdomen, Superficial Structures (Small Parts) now known as Abdominal Sonography-Extended, and Obstetrics and Gynecology (OB-GYN) this is also known as gravid and non-gravid female pelvis, and an introduction to vascular technology. The basic on-campus scanning procedures required are included within this handbook. Specific scanning procedures for each clinical site are beyond the scope of this document. Clinical education begins during the second semester and continues for three (3) semesters and one (1) summer term. Weekly clinical hours: a total of 1710 clinical hours are completed during three semesters and one summer term. Specific monthly schedules have been created to allow for students to enjoy all college identified holidays, and to be eligible to sit for board examinations through the American Registry for Diagnostic Medical Sonography (ARDMS) during the final semester. All clinical hours must be completed to be eligible for graduation. Whenever possible, each student will complete three (3) unique clinical experience rotations, to include 1 at least one at a medical center/hospital. The original design provided for four (4) rotations. Following advice from the Sonographic Advisory Board, the summer and fall terms have been combined to generate a better learning opportunity, albeit the students receive independent grades for each of the terms. Students will earn organ-specific scanning competencies during these clinical rotations. School Facilities include dedicated sonographic lecture room and laboratory. The classroom has tables and chairs, rather than traditional student desks. Audio/visual equipment includes a PC, mounted overhead projector, and sound system in both rooms. The scanning laboratory is equipped with three ultrasound systems. The laboratory is equipped with three state-of-the technology imaging systems. Each system is from an independent vendor which prepares students to apply physical principles knowledge in a variety of clinical facilities. The three scanning systems include: A Samsung unit with panoramic imaging, 3-D endovaginal probe, and multiple sonographic programs for abdomen, superficial structures, OB-GYN, vascular, and echocardiography examinations. Another modern GE system was installed in January of 2017, and in July 2018 a Mindray system completed the trio. Each scanning system has multiple transducers. When combined, advanced imaging technology includes elastography, 3-D, 4-D, panoramic, and Doppler applications. Each scanning station is equipped with ergonomic scanning tables and chairs, patient positioning tools, thermographic printers, and gel warmers. New for 2020: SonoSim Training System that features 24/7 access to 65 courses with knowledge assessment, hands-on simulation, and performance tracking. Each sonography student has didactic access throughout the program. Mock transducer-hands-on simulation is available during the second semester. Students’ use their personal computer, laptop, or smart phone to access the entire complement of sonographic scanning applications available from the SonoSim system. The program believes that actual real time scanning using 2 breathing individuals is the best approach for initial scanning skill development. However, the class of 2020 found that the SonoSim Training System was exceedingly beneficial in strengthening skillsets when laboratory course time, and some clinical rotations were canceled due to the COVID Pandemic. Each student has an assigned individual simulation packet. The sonography suite houses multiple sophisticated scanning phantoms for structures that cannot be readily scanned on a college campus. These include three second trimester OB phantoms, a breast phantom, a scrotal phantom, and three endocavitary pelvic capable of transabdominal applications each with different female pathology including a mock ectopic pregnancy, Other phantoms include a full adult abdomen and thorax with a variety of pathologies, a full pediatric abdomen and thorax with pediatric specific abnormalities, a pediatric hip phantom, and two neonatal brain units. These phantoms may be scanned using the technologically advanced imaging systems, or the students may use one of the eight I-Pad/SonoStar wireless scanning systems. Each I- Pad is partnered with either a curvilinear or linear SonoStar probe. The ultrasound laboratory houses several sonographic textbooks and study aids, and a vast collection of SDMS and AIUM journals. The allied health building provides a computer laboratory available for scheduled classes and open study. The campus library is found in the heart of the campus and maintains ultrasound books and reference materials including CD-DVD. Individual study rooms and personal computers are available. To maintain continued programmatic eligibility: the student must complete all didactic, laboratory and clinical experience courses sequentially to progress through the program. 3 Students complete courses in: Ultrasound Physics & Instrumentation (SONO40, 40L, and 44A), Abdominal and Superficial Structure Applications (SONO 41, 41L, 42A, 42L, 44C, 44CL), OB-GYN (SONO43A, 43L), Introduction to Vascular (SONO45C, 45CL), Integrative Applications (SONO 45A), and Clinical Experience (SONO 42B, 43B, 44B, 45B). Diagnostic Medical Sonography Program Projected Class Schedule Semester Course Monday Tuesday Wednesday Thursday Friday SONO 40 (lecture) 9-9:50 am SONO 40L (lab) 10-11:15 am Fall SONO 41 (lecture) 9-9:50 am 18 weeks SONO 41L (lab) 10-11:15 am SONO 42A 8-10:50 am Spring (Lecture) 18 weeks SONO 42L (lab) 12-3:00 pm SONO 42B (clinic) ~32 hours/week 4 days/8 hours SONO 44A (lecture) 8-11:10 am SONO 44C (lecture) 12-12:50 pm Summer SONO 44CL (lab) 1-4:15 pm 8 weeks SONO 44B (clinic) ~32 hours/week 4 days/ 8 hours SONO 43A (lecture) 8-11:00 am SONO 43AL (lab) 12-3:00 pm Fall SONO 43B (clinic) ~32 hours each week 18 weeks 4 days @ 8 hours SONO 45A (lecture) 12-1:50 pm SONO 45C (Lecture) 8-9:15 am SONO 45CL (lab) 10-11:15 am Spring SONO 45B (clinic) ~32hours each week Total of 1710 clinical hours 18 weeks 4 days @ 8 hours Disclaimer: The DMS program reserves the right to revise class schedules at any time. This schedule is to be used for general reference only. During COVID-19 lectures and some labs were delivered via: hybrid and distance delivery. Most courses remained synchronous, but when required, asynchronous delivery was implemented. Revised 11/2018, 12/20 4 I. Introduction A. Welcome Welcome to the Diagnostic Medical Sonography Program! As the Director, it is my pleasure to congratulate you on your acceptance to the program, and to wish you success in your newly chosen health career. As a student in the Diagnostic Medical Sonography Program, you represent Merced College and the Diagnostic Medical Sonography program. The highest ethical and professional standards of conduct will be always expected of you. You are responsible for learning the material (reading; studying; practicing in open lab; attending class, lab, and clinic; and developing the skills and behaviors of a sonographer); time management, professional behavior, and enjoying every aspect of personal development in this exciting career. The Program Director directs and facilitates the educational experience/program with the desired final outcomes: the privilege for you to write RDMS (Registered Diagnostic Medical Sonographer) after your name, and to become an erudite sonographer. The Clinical Coordinator assists the program director in the creation of an excellent learning opportunity, by spending time in the ultrasound laboratory
Recommended publications
  • AIUM Practice Parameter for the Performance of an Ultrasound Examination of the Abdomen And/Or Retroperitoneum
    1 AIUM Practice Parameter for the Performance of an Ultrasound Examination of the Abdomen and/or Retroperitoneum Parameter developed in conjunction with the American College of Radiology (ACR), the Society for Pediatric Radiology (SPR), and the Society of Radiologists in Ultrasound (SRU). The American Institute of Ultrasound in Medicine (AIUM) is a multidisciplinary association dedicated to advancing the safe and effective use of ultrasound in medicine through professional and public education, research, development of parameters, and accreditation. To promote this mission, the AIUM is pleased to publish, in conjunction with the American College of Radiology (ACR), the Society for Pediatric Radiology (SPR), and the Society of Radiologists in Ultrasound (SRU), this AIUM Practice Parameter for the Performance of an Ultrasound Examination of the Abdomen and/or Retroperitoneum. We are indebted to the many volunteers who contributed their time, knowledge, and energy to bringing this document to completion. The AIUM represents the entire range of clinical and basic science interests in medical diagnostic ultrasound, and, with hundreds of volunteers, the AIUM has promoted the safe and effective use of ultrasound in clinical medicine for more than 65 years. This document and others like it will continue to advance this mission. © 2017 American Institute of Ultrasound in Medicine 14750 Sweitzer Ln, Suite 100 Laurel, MD 20707-5906 USA www.aium.org 2 Practice parameters of the AIUM are intended to provide the medical ultrasound community with parameters for the performance and recording of high-quality ultrasound examinations. The parameters reflect what the AIUM considers the minimum criteria for a complete examination in each area but are not intended to establish a legal standard of care.
    [Show full text]
  • Training in Diagnostic Ultrasound: Essentials, Principles and Standards
    This report contains the collective views of on international group of experts and does not necessarily represent the decisions or the stated policy offe World Health Organization TRAINING IN DIAGNOSTIC ULTRASOUND: ESSENTIALS, PRINCIPLES AND STANDARDS Report of a WHO Study Group Geneva 1998 WHO L~braryCataloguing In Publ~catlonData Training in diagnostic ultrasound : essentials, principles and standards : report of a WHO study group (WHO technical report series ; 875) 1 .Ultrasonography 2.Diagnostic imag~ng- standards 3.Guidelines 4.Health per- sonnel - education I Title II.Series (NLM Classification: WN 200) The World Health Organization welcomes requests for permission to reproduce or translate its publications, in part or in full Applications and enquiries should be addressed to the Office of Publications, World Health Organization, Geneva, Switzerland, which will be glad to prov~dethe latest information on any changes made to the text, plans for new editions, and reprlnts and translations already available. O World Health Organization 1998 Publications of the World Health Organization enjoy copyright protect~onin accordance with the provisions of Protocol 2 of the Universal Copyright Convention. All rights reserved. The designations employed and the presentation of the material in this publication do not imply the expression of any opnlon whatsoever on the part of the Secretariat of the World Health Organization concerning the legal status of any country, territory, city or area or of its authorities, or concerning the delimitation of its frontiers or boundaries. The mention of specific companies or of certain manufacturers' products does not imply that they are endorsed or recommended by the World Health Organ~zat~onin preference to others of a simllar nature that are not mentioned.
    [Show full text]
  • Incidental Findings General Medical Ultrasound Examinations: Management and Diagnostic Pathways Guidance
    w Incidental Findings General Medical Ultrasound Examinations: Management and Diagnostic Pathways Guidance September 2020 Acknowledgements The British Medical Ultrasound Society (BMUS) would like to acknowledge the work and assistance provided by the following in the production of this guideline: The Professional Standards Group BMUS 2019-2020: Chair: Mrs Catherine Kirkpatrick Consultant Sonographer Professor (Dr.) Rhodri Evans BMUS President. Consultant Radiologist Mrs Pamela Parker BMUS President Elect. Consultant Sonographer Dr Peter Cantin PhD. Consultant Sonographer Dr Oliver Byass. Consultant Radiologist Miss Alison Hall Consultant Sonographer Mrs Hazel Edwards Sonographer Mr Gerry Johnson Consultant Sonographer Dr. Mike Smith PhD. Physiotherapist/Senior Lecturer Professor (Dr.) Adrian Lim, Consultant Radiologist In addition, the documentation and protocol evidence from Hull University Teaching Hospitals NHS Trust, Plymouth NHS Trusts and United Lincolnshire Hospitals NHS Trust for template derivation. Foreword The introduction of this guidance document regarding the diagnosis and management of incidental findings is timely. The changing landscapes of ultrasound practice combined with the significant communication challenges within a variety of referral sources can often add to the pressures exerted on the ultrasound practitioner. The demand for diagnostic ultrasound examinations is ever increasing. Faster patient throughput and increasing complexities of patient management, coupled with advancing ultrasound technologies leads to an inevitable increase in ‘incidentalomas’. The challenges facing ultrasound practitioners include the re-definition of ‘normal’ due to increased resolution of imaging, dilemmas around reporting of incidental findings and managing the effects of this for the patients and the referring clinicians. These guidelines are a resource that can be used as a basis for diagnostic pathways and reporting protocols, and can be modified as appropriate to align with locally agreed protocols.
    [Show full text]
  • LNCS 5242, Pp
    Real-Time Simulation of Medical Ultrasound from CT Images Ramtin Shams1, Richard Hartley1,2, and Nassir Navab3 1 RSISE, The Australian National University, Canberra 2 NICTA, Canberra, Australia 3 Computer Aided Medical Procedures (CAMP), TU M¨unchen, Germany Abstract. Medical ultrasound interpretation requires a great deal of experience. Real-time simulation of medical ultrasound provides a cost- effective tool for training and easy access to a variety of cases and ex- ercises. However, fully synthetic and realistic simulation of ultrasound is complex and extremely time-consuming. In this paper, we present a novel method for simulation of ultrasound images from 3D CT scans by breaking down the computations into a preprocessing and a run-time phase. The preprocessing phase produces detailed fixed-view 3D scatter- ing images and the run-time phase generates view-dependent ultrasonic artifacts for a given aperture geometry and position within a volume of interest. We develop a simple acoustic model of the ultrasound for the run-time phase, which produces realistic ultrasound images in real-time when combined with the previously computed scattering image. 1 Introduction Ultrasound is a challenging imaging modality to master due to a multitude of pa- rameters involved in acquisition and interpretation of resulting images. Real-time simulation of ultrasound can be used for training to complement a theoretical study program. A recent study in [1] reports a significant improvement in skills of subjects who received additional simulator-based training. The main advantage is easy access to a wealth of standard and rare cases collected over time. Existing methods for real-time simulation of ultrasound such as [2,3,4] are based on acquisition of actual ultrasound images and creating a compounded 3D volume of the region of interest.
    [Show full text]
  • Scope of Practice and Clinical Standards for the Diagnostic Medical Sonographer
    Scope of Practice and Clinical Standards for the Diagnostic Medical Sonographer April 13, 2015 This page intentionally left blank. © 2013-2015 by the participating organizations as a “joint work” as defined in 17 U.S. Code § 101 (the Copyright Act). Contact the Society of Diagnostic Medical Sonography for more information. 2 SCOPE OF PRACTICE REVISION PROCESS In May 2013, representatives of sixteen organizations came together to begin the process of revising the existing Scope of Practice and Clinical Practice Standards. Thus began a process that engaged the participating organizations in an unrestricted dialogue about needed changes. The collaborative process and exchange of ideas has led to this document, which is reflective of the current community standard of care. The current participants recommend a similar collaborative process for future revisions that may be required as changes in ultrasound technologies and healthcare occur. PARTICIPATING ORGANIZATIONS The following organizations participated in the development of this document. Those organizations that have formally endorsed the document are identified with the “†” symbol. Supporting organizations are identified with the "*" symbol. • American College of Radiology (ACR) * • American Congress of Obstetricians and Gynecologists (ACOG) * • American Institute of Ultrasound in Medicine (AIUM) * • American Registry for Diagnostic Medical Sonography (ARDMS) * • American Registry of Radiologic Technologists (ARRT) * • American Society of Echocardiography (ASE) † • American Society of
    [Show full text]
  • Breast Ultrasound Tomography with Two Parallel Transducer Arrays
    Breast ultrasound tomography with two parallel transducer arrays Lianjie Huang, Junseob Shin, Ting Chen, Youzuo Lin, Kai Gao, Miranda Intrator, Kenneth Hanson Los Alamos National Laboratory, MS D452, Los Alamos, NM 87545, USA ABSTRACT Breast ultrasound tomography is an emerging imaging modality to reconstruct the sound speed, density, and ultrasound attenuation of the breast in addition to ultrasound reflection/beamforming images for breast cancer detection and charac- terization. We recently designed and manufactured a new synthetic-aperture breast ultrasound tomography prototype with two parallel transducer arrays consisting of a total of 768 transducer elements. The transducer arrays are translated verti- cally to scan the breast in a warm water tank from the chest wall/axillary region to the nipple region to acquire ultrasound transmission and reflection data for whole-breast ultrasound tomography imaging. The distance of these two ultrasound transducer arrays is adjustable for scanning breasts with different sizes. We use our breast ultrasound tomography pro- totype to acquire phantom and in vivo patient ultrasound data to study its feasibility for breast imaging. We apply our recently developed ultrasound imaging and tomography algorithms to ultrasound data acquired using our breast ultrasound tomography system. Our in vivo patient imaging results demonstrate that our breast ultrasound tomography can detect breast lesions shown on clinical ultrasound and mammographic images. Keywords: Breast cancer, reflection, sound speed, synthetic-aperture ultrasound, transmission, ultrasound attenuation, ultrasound imaging, ultrasound tomography. 1. INTRODUCTION Breast cancer is the second-leading cause of cancer death among American women. The breast cancer mortality rate in the U.S. changed little from 1930s-1990s, and has decreased only approximately 20% since the 1990s.
    [Show full text]
  • MI Lab 2011, Images and Stories
    www.ntnu.no/milab MI Lab 2011 MI Lab 2011 Verdana Impact Established by the Research Council of Norway Verdana Impact Established by the Research Council of Norway MI Lab partners MI Lab 2011 MI Lab partners TM MI Lab leader published. These two landmarks confirm the MI Lab Professor olav Haraldseth vision that innovations in medical imaging can facilitate [email protected] cost efficient health care and improved patient outcome at the same time. For MI Lab 2011 was a good year. As MI Lab leader I am happy about two things: We now have a broad research • It is nice to see the competence and enthusiasm of activity with a multi-disciplinary the group of PhD and post doc students. They obtain group of 31 on-going PhD experience in medical R&D in the crossroad between students and post doctoral fellows, and we c ontinuously university, industry and hospital, and will be a future get new ideas that have potential for the MI Lab vision of pool for recruitment of high-quality personnel for inventions that may facilitate cost efficient health care Norwegian industrial R&D, health care and academia. and improved patient outcome. • Our experience so far is that we in MI Lab are able to build an arena for open innovation and long-term The MI Lab partner MediStim ASA obtained an official industrial research with high scientific quality and recommendation in the United Kingdom of the health good commitment from the partners. In 2011 this benefits of the ultrasound system VeriQ: “The case resulted in a publication list of 34 scientific papers for adopting the VeriQ system in the National Health printed in international journals with referee, and MI System for assessing graft flow during coronary artery Lab also have several important inventions in differ- bypass graft surgery is supported by the evidence.
    [Show full text]
  • Real Time Volumetric Ultrasound Imaging System and Extensive Operator Interaction That Preclude Has Been Developed for Medical Diagnosis
    Real Time Volumetric Ultrasound lmaging System Olaf T. von Ramm and Stephen W. Smith A real time volumetric ultrasound imaging system and extensive operator interaction that preclude has been developed for medical diagnosis. The scan- imaging of dynamic structures without sophisti- ner produces images analogous to ah optical camera cated gating techniques. and supplies more information than conventional sonograms. Potential medical applications include In the field of diagnostic ultrasound, 3D imag- improved anatomic visualization, tumor tocalization, ings systems have been proposed in the past. and better assessment of cardiac function. The However, these have been too slow for clinical system uses pulsa-echo phased array principias to applications 4'5 or have operated primarily in a steer a two-dimensional erray trensducer of 289 through-transmission mode requiring a complex elements in a pyramidal sean format. Parallel process- ing in the receive moda produces 4992 scan lines eta water-path apparatus. 6'70ur objective was to rata of approximately 8 frames/second. Echo data develop ah ultrasound system, which uses a for the scanned volume is presented es projection hand-held transducer, capable of scanning a images with depth perspectiva, steraoscopic pairs, volume rapidly and enabling the 3-D visualiza- multiple tomographic images, or C-moda scans. tion of dynamic structures in real time. 9 1990 by W.B. Saunders Company. In order to extend cross-sectional ultrasound KEY WORDS: diagnostic ultrasound, phased array. imaging to volumetric imaging, three advances three-dimensional, volumetric, diagnostic imaging, were necessary: (1) a hand-held transducer was real time. needed that could be steered rapidly and focused at ~.ny desired orientation in the volume; (2) the A HIGH-SPEED volumetric ultrasound imag- data acquisition rate had to be increased signifi- ing system that uses pulse-echo principles cantly to obtain image data from many planes in analogous to sonar and radar has been developed real time; (3) a display method was required, for medical application.
    [Show full text]
  • Guidelines for Professional Ultrasound Practice
    Guidelines For Professional Ultrasound Practice Society and College of Radiographers and British Medical Ultrasound Society December 2015 Revision 2, December 2017 SCoR/BMUS Guidelines for Professional Ultrasound Practice. Revision 2. December 2017. SOCIETY AND COLLEGE OF RADIOGRAPHERS AND BRITISH MEDICAL ULTRASOUND SOCIETY GUIDELINES FOR PROFESSIONAL ULTRASOUND PRACTICE DECEMBER 2015 Revision 2, December 2017. LIST OF CONTENTS Acknowledgements 3 Foreword 5 Revision 1, December 2016 6 Revision 2, December 2017 Introduction 7 Section 1 General information 1.1 Explanation of the professional title ‘sonographer’ 9 1.2 Registration for sonographers 10 1.3 Professional Indemnity Insurance 11 1.4 Profession vs tool 11 1.5 Safety of medical ultrasound 12 1.6 Medico-legal issues 13 1.7 Transducer cleaning and disinfection 14 1.8 Screening examinations using ultrasound 15 1.9 Ergonomic practice including managing the high BMI patient 17 1.10 Intimate examinations and chaperones 18 1.11 Examination times 20 1.12 Communication, ID and consent 21 1.13 Clinical governance 23 1.14 E-Learning for Healthcare (E-LfH) 25 1.15 Imaging Services Accreditation Scheme (ISAS) 25 1.16 Ultrasound equipment and quality assurance testing 26 1.17 Raising concerns; safeguarding; statutory requirements for reporting female genital mutilation; Duty of Candour. 1.18 Continuing professional development (CPD) 28 1.19 Codes of professional conduct for sonographers 29 1.20 Independent practice 31 Section 2 The ultrasound examination 2.1 Overview of ultrasound examination procedures 33 2.2 Obstetric, vascular and echocardiography examinations 33 2.3 NICE and other guidelines 34 1 SCoR/BMUS Guidelines for Professional Ultrasound Practice.
    [Show full text]
  • Operator's Manual [Basic Volume]
    TE7 Diagnostic Ultrasound System Operator’s Manual [Advanced Volume] Content Content ................................................................................................................................. i Intellectual Property Statement ...................................................................................................... I Preface ........................................................................................................................................ II Safety Precautions ...................................................................................................................... III 1 Overview .................................................................................................................... 1-1 1.1 Basic Operations and Buttons ......................................................................................... 1-1 1.2 Measurement Menu......................................................................................................... 1-1 1.2.1 Measurement Location ............................................................................................. 1-2 1.2.2 Measurement Tool.................................................................................................... 1-2 1.3 Measurement, Calculation and Study ............................................................................... 1-3 1.4 Measurement Caliper ...................................................................................................... 1-4 1.5 Results Window..............................................................................................................
    [Show full text]
  • Manual of Diagnostic Ultrasound Iagnostic U Vol
    Vol. 2 0.1 Manual of d Manual of diagnostic ultrasound iagnostic vol. 2 During the last decades , use of ultrasonography became increasingly common in medical practice and hospitals around u the world, and a large number of scientific publications reported ltrasound the benefit and even the superiority of ultrasonography over commonly used X-ray techniques, resulting in significant changes in diagnostic imaging procedures. With increasing use of ultrasonography in medical settings, the need for education and training became essential. WHO took Manual of up this challenge and in 1995 published its first training manual in ultrasonography. Soon, however, rapid developments and improvements in equipment and indications for the extension of diagnostic ultrasound medical ultrasonography into therapy indicated the need for a totally new ultrasonography manual. volume2 The manual (consisting of two volumes) has been written by an international group of experts of the World Federation for Ultrasound in Medicine and Biology (WFUMB), well-known for their publications regarding the clinical use of ultrasound and with substantial experience in the teaching of ultrasonography in both developed and developing countries. The contributors (more than fifty for the two volumes) belong to five different continents, to guarantee that manual content represents all clinical, cultural and epidemiological contexts This new publication, which covers modern diagnostic and therapeutic ultrasonography extensively, will certainly benefit Second edition and inspire medical professionals in improving ‘health for all’ in both developed and emerging countries. cm/s 60 [TIB 1.3] 7.5L40/4.0 40 SCHILDDR. 100% 48dB ZD4 20 4.0cm 11B/s 0 Z ISBN 978 92 4 154854 0 THI CF5.1MHz -20 PRF1102Hz F-Mittel 70dB ZD6 DF5.5MHz PRF5208Hz 62dB FT25 FG1.0 DIM Cover_Final Proof.indd 1 7/1/13 6:47 AM 0.1 Manual of diagnostic ultrasound volume2 Second edition cm/s 60 [TIB 1.3] 7.5L40/4.0 40 SCHILDDR.
    [Show full text]
  • Guidelines for Professional Ultrasound
    Guidelines For Professional Ultrasound Society and College of Radiographers and British Medical Ultrasound Society Revision 3, December 2018 SCoR/BMUS Guidelines for Professional Ultrasound Practice. Revision 3, December 2018 Minor amendments, March 2019. SOCIETY AND COLLEGE OF RADIOGRAPHERS AND BRITISH MEDICAL ULTRASOUND SOCIETY GUIDELINES FOR PROFESSIONAL ULTRASOUND PRACTICE DECEMBER 2015 Revision 3, December 2018. Minor amendments, March 2019 Contents Acknowledgements ...................................................................................................................................................... 4 Foreword ...................................................................................................................................................................... 6 December 2015 edition ........................................................................................................................................ 6 Revision 1, December 2016 .................................................................................................................................. 6 Revision 2, December 2017 .................................................................................................................................. 7 Revision 3, December 2018. Minor post publication amends March 2019 ....................................................... 7 SECTION 1: GENERAL INFORMATION ........................................................................................................................
    [Show full text]