TYPE W - Hi Delta s1
Total Page:16
File Type:pdf, Size:1020Kb
Job: Engineer: Contractor: Prepared By: Date: Model: Indoor/Outdoor:
96% Thermal Efficiency at Full Rate; Up to 99% at Part Load 100% Factory Fire Tested VERSA IC™ Modulating Controller with LCD Display Full Electronic Modulation, Constant Ratio 7:1 Turndown Full Safety Diagnostics with History Status Display Lights Cascade up to 4 Heaters – No External Sequencer Required Modbus RTU BMS Port Maximum Outlet Water Temperature: 235°F Minimum Inlet Water Temperature: 50°F Limited Twenty-Five-Year Thermal Shock Warranty Limited Ten-Year Primary Heat Exchanger Warranty Limited Ten-Year SecondaryHeat Exchanger Warranty Heat Exchanger System By others Programmable Pump Time Delays Headers Not required Cast Iron – Standard LCD Display: Status, Fault and Diagnostics Modulating Temperature Control; 7:1 turndown Bronze – Option A-1 Water Temperature Sensors (7) Options ASME H Stamped; 160 PSIG MAWP Cold Water Protection – Built In D-32 PVC Vent Adapter National Board Listed Blocked Condensate Switch (Includes 162ºF Manual High Fin Tubing Modbus RTU BMS Port (Up to 115K Baud Limit) (Factory installed only) Copper – Standard Rate, see Cat. No. 5000.73) D-33 Centrotherm™ Polypropylene B-85 BMS Gateway, Modbus RTU to Cupro Nickel – Option A-3 Vent Adapter(Includes 180ºF Modbus TCP, N2 Metasys, BACnet IP, or ASME Powder-Coated Tube Sheet Manual High Limit) (shipped BACnet MS/TP Silicone High Temp O-Rings B-86 BMS Gateway, Modbus RTU to loose) ASME Pressure Relief Valve F-10 Low Water Cut-Off, Remote 60 PSIG – Standard LonWorks Probe PSIG – Optional Burner I-1 High Limit, Auto Reset, Adj., Radially Fired Knitted Burner 150 PSI Air Vent, Auto 100-240°F T&P Gauge,Shipped Loose Gas Train I-2 High Limit, Manual Reset, Adj., Stainless Steel Secondary Heat Exchanger Fuel 100-240°F Stainless Steel Evaporator Plate Natural Gas Boiler Pump: 120V, 1, 60Hz; S-1 Low Gas Pressure Switch, Propane Cast Iron – Standard Manual Reset Bronze – Option Dual-Seat Combination Valve S-2 High Gas Pressure Switch, Manual Shut Off Firing Valve Manual Reset Control Construction Z-12 Condensate Neutralizer Kit 120V, 60Hz, 1Ø, Power Supply Indoor/Outdoor Construction 120/24V 60Hz Transformer Enclosed Front Controls Regulatory Agency Requirements Ignition Module PolyTuf Powder Coat Finish 3-Try – Standard Rear Connections (Water, Gas, Vent, Single-Try – Option C-6 Electrical, Comb. Air, Cond. Drain) Combustion Air Filter Multi-Boiler Digital Temp Controllers Hot Surface Ignition (HSI) Design Certified ANSI Z21.13/CSA 4.9 B-36 TempTracker Mod+ Hybrid, Remote Flame Sensor Front Connection Low Voltage Wiring Fixed High Limit, Manual Reset, 240°F 2-4 Boilers, OA Reset On/Off Power Switch Venting B-37 TempTracker Mod+ Hybrid, Flow Switch Vent Termination, Cat IV 5-10 Boilers, OA Reset Blocked Vent Pressure Switch Outdoor or Indoor, Vertical – B-38 TempTracker Mod+ Hybrid, Freeze Protection Option D-11 Alarm Dry Contact Indoor, Horizontal –Option D-15 11-16 Boilers, OA Reset Pump Outputs – Pilot Duty B-39* EMS 4-20 mA Remote Setpoint DHW Indirect Extractor – Optional, Cat II Interface Module
Catalog No.: 2000.61D Effective: 07-01-13 Replaces: 12-01-10 B-62* BACnet MS/TP Interface Module (*only used with B-36 to B-38)
XTherm – Type H Models 1005A-2005A Model
Ship Dimensions (in) Weight MBTUH Model (Lbs.) (H7-) B G* NPT K N R Heigh D E Flue L M C/A Y Input Output t Ø Ø 1005 999 959 55-1/8 45 47-1/8 36-1/2 1-1/4 6 40-1/16 11-1/2 6 47-1/8 8-1/16 6-1/16 1065 A 1505 59- 1500 1440 67-1/8 57 38-1/2 1-1/4 8 52-1/16 12-5/8 8 59-1/8 8-3/16 6-1/16 1234 A 1/16 2005 71- 1999 1919 81-1/8 71 38-1/2 2 8 64-1/16 12-5/8 8 73-1/8 8-3/16 6-1/4 1461 A 3/16 Note: Ratings shown are for elevations up to 4,500 feet. For installations at elevations * For Propane Gas, all models are 1” NPT above 4,500 feet, please consult the factory for additional instructions.
Syste Model 1005A Model 1505A Model 2005A m Return Supply Minimum Pipe Size2 Supply Minimum Pipe Size2 Supply Minimum Pipe Size2
Catalog No.: 3200.20K Effective: 7-15-99 Replaces: 7-1-99 Temp1 (ºF) <80’ eq 80-200’ eq Temp1 (ºF) <80’ eq 80-200’ eq Temp1 (ºF) <80’ eq 80-200’ eq Temp 60 138 2” NPT 2-1/2” NPT 147 2” NPT 2-1/2” NPT 154 2” NPT 2-1/2” NPT 80 138 2” NPT 2-1/2” NPT 147 2” NPT 2-1/2” NPT 154 2-1/2” NPT 3” NPT 100 138 2-1/2” NPT 3” NPT 147 2-1/2” NPT 3” NPT 154 2-1/2” NPT 3” NPT 120 145 2-1/2” NPT 3” NPT 158 2-1/2” NPT 3” NPT 170 2-1/2” NPT 3” NPT 140 165 2-1/2” NPT 3” NPT 178 2-1/2” NPT 3” NPT 190 2-1/2” NPT 3” NPT 160 185 2-1/2” NPT 3” NPT 198 2-1/2” NPT 3” NPT 210 2-1/2” NPT 3” NPT
1 – Approximate high fire heater outlet temperature based on the standard heater pump and recommended connecting pipe size. 2 – Minimum pipe size based on total equivalent feet of supply and return piping between the system loop and heater.
Catalog No.: 2000.61D Effective: 07-01-13 Replaces: 12-01-10