TYPE W - Hi Delta s1

TYPE W - Hi Delta s1

<p>Job: Engineer: Contractor: Prepared By: Date: Model: Indoor/Outdoor: </p><p>96% Thermal Efficiency at Full Rate; Up to 99% at Part Load 100% Factory Fire Tested VERSA IC™ Modulating Controller with LCD Display Full Electronic Modulation, Constant Ratio 7:1 Turndown Full Safety Diagnostics with History Status Display Lights Cascade up to 4 Heaters – No External Sequencer Required Modbus RTU BMS Port Maximum Outlet Water Temperature: 235°F Minimum Inlet Water Temperature: 50°F Limited Twenty-Five-Year Thermal Shock Warranty Limited Ten-Year Primary Heat Exchanger Warranty Limited Ten-Year SecondaryHeat Exchanger Warranty Heat Exchanger System By others Programmable Pump Time Delays Headers Not required Cast Iron – Standard LCD Display: Status, Fault and Diagnostics Modulating Temperature Control; 7:1 turndown Bronze – Option A-1 Water Temperature Sensors (7) Options ASME H Stamped; 160 PSIG MAWP Cold Water Protection – Built In D-32 PVC Vent Adapter National Board Listed Blocked Condensate Switch (Includes 162ºF Manual High Fin Tubing Modbus RTU BMS Port (Up to 115K Baud Limit) (Factory installed only) Copper – Standard Rate, see Cat. No. 5000.73) D-33 Centrotherm™ Polypropylene B-85 BMS Gateway, Modbus RTU to Cupro Nickel – Option A-3 Vent Adapter(Includes 180ºF Modbus TCP, N2 Metasys, BACnet IP, or ASME Powder-Coated Tube Sheet Manual High Limit) (shipped BACnet MS/TP Silicone High Temp O-Rings B-86 BMS Gateway, Modbus RTU to loose) ASME Pressure Relief Valve F-10 Low Water Cut-Off, Remote 60 PSIG – Standard LonWorks Probe PSIG – Optional Burner I-1 High Limit, Auto Reset, Adj., Radially Fired Knitted Burner 150 PSI Air Vent, Auto 100-240°F T&P Gauge,Shipped Loose Gas Train I-2 High Limit, Manual Reset, Adj., Stainless Steel Secondary Heat Exchanger Fuel 100-240°F Stainless Steel Evaporator Plate Natural Gas Boiler Pump: 120V, 1, 60Hz; S-1 Low Gas Pressure Switch, Propane Cast Iron – Standard Manual Reset Bronze – Option Dual-Seat Combination Valve S-2 High Gas Pressure Switch, Manual Shut Off Firing Valve Manual Reset Control Construction Z-12 Condensate Neutralizer Kit 120V, 60Hz, 1Ø, Power Supply Indoor/Outdoor Construction 120/24V 60Hz Transformer Enclosed Front Controls Regulatory Agency Requirements Ignition Module PolyTuf Powder Coat Finish 3-Try – Standard Rear Connections (Water, Gas, Vent, Single-Try – Option C-6 Electrical, Comb. Air, Cond. Drain) Combustion Air Filter Multi-Boiler Digital Temp Controllers Hot Surface Ignition (HSI) Design Certified ANSI Z21.13/CSA 4.9 B-36 TempTracker Mod+ Hybrid, Remote Flame Sensor Front Connection Low Voltage Wiring Fixed High Limit, Manual Reset, 240°F 2-4 Boilers, OA Reset On/Off Power Switch Venting B-37 TempTracker Mod+ Hybrid, Flow Switch Vent Termination, Cat IV 5-10 Boilers, OA Reset Blocked Vent Pressure Switch Outdoor or Indoor, Vertical – B-38 TempTracker Mod+ Hybrid, Freeze Protection Option D-11 Alarm Dry Contact Indoor, Horizontal –Option D-15 11-16 Boilers, OA Reset Pump Outputs – Pilot Duty B-39* EMS 4-20 mA Remote Setpoint DHW Indirect Extractor – Optional, Cat II Interface Module</p><p>Catalog No.: 2000.61D Effective: 07-01-13 Replaces: 12-01-10 B-62* BACnet MS/TP Interface Module (*only used with B-36 to B-38)</p><p>XTherm – Type H Models 1005A-2005A Model </p><p>Ship Dimensions (in) Weight MBTUH Model (Lbs.) (H7-) B G* NPT K N R Heigh D E Flue L M C/A Y Input Output t Ø Ø 1005 999 959 55-1/8 45 47-1/8 36-1/2 1-1/4 6 40-1/16 11-1/2 6 47-1/8 8-1/16 6-1/16 1065 A 1505 59- 1500 1440 67-1/8 57 38-1/2 1-1/4 8 52-1/16 12-5/8 8 59-1/8 8-3/16 6-1/16 1234 A 1/16 2005 71- 1999 1919 81-1/8 71 38-1/2 2 8 64-1/16 12-5/8 8 73-1/8 8-3/16 6-1/4 1461 A 3/16 Note: Ratings shown are for elevations up to 4,500 feet. For installations at elevations * For Propane Gas, all models are 1” NPT above 4,500 feet, please consult the factory for additional instructions.</p><p>Syste Model 1005A Model 1505A Model 2005A m Return Supply Minimum Pipe Size2 Supply Minimum Pipe Size2 Supply Minimum Pipe Size2</p><p>Catalog No.: 3200.20K Effective: 7-15-99 Replaces: 7-1-99 Temp1 (ºF) <80’ eq 80-200’ eq Temp1 (ºF) <80’ eq 80-200’ eq Temp1 (ºF) <80’ eq 80-200’ eq Temp 60 138 2” NPT 2-1/2” NPT 147 2” NPT 2-1/2” NPT 154 2” NPT 2-1/2” NPT 80 138 2” NPT 2-1/2” NPT 147 2” NPT 2-1/2” NPT 154 2-1/2” NPT 3” NPT 100 138 2-1/2” NPT 3” NPT 147 2-1/2” NPT 3” NPT 154 2-1/2” NPT 3” NPT 120 145 2-1/2” NPT 3” NPT 158 2-1/2” NPT 3” NPT 170 2-1/2” NPT 3” NPT 140 165 2-1/2” NPT 3” NPT 178 2-1/2” NPT 3” NPT 190 2-1/2” NPT 3” NPT 160 185 2-1/2” NPT 3” NPT 198 2-1/2” NPT 3” NPT 210 2-1/2” NPT 3” NPT</p><p>1 – Approximate high fire heater outlet temperature based on the standard heater pump and recommended connecting pipe size. 2 – Minimum pipe size based on total equivalent feet of supply and return piping between the system loop and heater.</p><p>Catalog No.: 2000.61D Effective: 07-01-13 Replaces: 12-01-10</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    3 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us