Battery Backup Sump Pump System
Total Page:16
File Type:pdf, Size:1020Kb
Battery Backup Sump Pump Instruction Manual System & Safety Warnings Table of Contents Important Safety Warnings and Understanding the Warning Instructions Lights and Alarms Electrical Precautions 1 Silencing the Alarm Battery Preparation 1 During an Emergency 11 Battery Precautions 1 Battery Alarm 11 Cleaning Battery Terminals 11,12 Introduction Replacing the Battery 12 Items Included in System 2 Fuse Alarm 13 Additional Items Needed 2 Water Alarm 13 System Specifications 2 Pump Alarm 14 Replacement Parts List 2 Replacing the Pump 14 Power Alarm 15 Pump & Pipe Charging 15 Installation Instructions System Operating 15 Installation Options 3 Direct Discharge to Outside 4 Testing the System Connection to Existing Discharge 5 Test-Reset-Silence Button 15 Direct Discharge for Narrow Sumps 6 Testing the Float Switch 15 Connection to Existing Discharge for Narrow Sumps 7 Parts & Service Information Technical Support 15 Battery Instructions Preparation of the Battery 8,9 Troubleshooting Guide 16 Control Unit Connections Warranty 17 Positioning the Float Switch 9 Connecting the Pump 9 Other Products 18 Installing the Battery Fluid Sensor 10 Connecting the Battery 10 Connecting the Charger 10 IMPORTANT: Even if you have the Basement Watchdog Special Backup Sump Pump System installed by someone else, you must read and follow the safety information contained in this manual. Failure to do so could result in property damage, serious injury, or death. Important Safety • DO NOT use an extension cord unless • Battery posts and terminals contain lead and absolutely necessary. If an extension cord lead compounds, chemicals known to the State Warnings & Instructions must be used, be sure the plug has the same of California to cause cancer and reproductive configuration as the plug on the control unit. harm. Wash hands after handling. SAVE THESE INSTRUCTIONS. This manual • DO NOT use an attachment not recommended contains important SAFETY WARNINGS and or sold by the manufacturer. It may result in OPERATING INSTRUCTIONS for the Basement a risk of fire or injury from an electrical shock. BATTERY PRECAUTIONS Watchdog Special battery backup sump pump • DO NOT operate the control unit if it has ! DANGER system. You will need to refer to it before received a sharp blow, been dropped, or attempting any installation or maintenance. otherwise damaged in any way. Explosive gases could cause serious injury or POSITIVE POST HAS NEGATIVE POST HAS ALWAYS keep these instructions with the unit so • DO NOT disassemble the control unit. death. Cigarettes, flames or sparks could LARGER DIAMETER SMALLER DIAMETER that they will be easily accessible. cause battery to explode in enclosed spaces. When service is required, contact Glentronics Charge in a well-ventilated area. Always • When connecting the battery cables, first Failure to read and follow these warnings and technical support at 800-991-0466, option #3 , shield eyes and face from battery. Keep vent connect the small ring on the end of the instructions could result in property damage, or send an e-mail to [email protected] . caps tight and level. BLACK wire to the NEGATIVE (-) post of the serious injury, or death. It is important to read Return the control unit to the manufacturer for battery, and then connect the large ring on the any repairs at the following address: this manual, even if you did not install the To help reduce these risks, observe the end of the RED wire to the POSITIVE (+) post Basement Watchdog backup sump pump system, Glentronics, Inc. following precautions: of the battery. since this manual contains safety information 645 Heathrow Drive • NEVER smoke or allow a spark or flame in the regarding the use and maintenance of this Lincolnshire, IL 60069-4205 vicinity of the battery. product. DO NOT DISCARD THIS MANUAL. • Use the Basement Watchdog control unit for charging a LEAD-ACID battery only. DO NOT ELECTRICAL PRECAUTIONS BATTERY PREPARATION use the control unit for charging dry-cell batteries that are most commonly used with ! WARNING / POISON ! DANGER home appliances. Sulfuric acid can cause blindness or severe Risk of electrical and fire hazard. May result • Be sure the area around the battery is well- burns. Avoid contact with skin, eyes, or in death, serious injury, shock or burns. ventilated. clothing. In the event of an accident, flush • When cleaning or adding water to the battery, with water and call a physician immediately. To help reduce these risks, observe the first fan the top of the battery with a piece of KEEP OUT OF REACH OF CHILDREN. POSITIVE NEGATIVE following precautions: cardboard (or another non-metallic material) POST POST • DO NOT walk on wet areas of the basement To help reduce these risks, observe the to blow away any hydrogen or oxygen gas that until all power has been turned off. If the following precautions: may have been emitted from the battery. main power supply is in a wet basement, call • Someone should be within range of your voice • DO NOT drop a metal tool onto the battery. It ! DANGER an electrician. or close enough to come to your aid when you might spark or short-circuit the battery and • NEVER handle the control unit with wet hands work near a lead-acid battery. cause an explosion. Do not use this system to pump flammable or while standing on a wet surface. • Have plenty of fresh water and soap nearby in • Remove personal metal items such as rings, or explosive fluids such as gasoline, fuel oil, • ALWAYS unplug the control unit and case battery acid contacts skin, clothing or bracelets, watches, etc. when working with a kerosene, etc. disconnect the cables from the battery before eyes. lead-acid battery. A short circuit through one attempting any maintenance or cleaning. • Wear eye and clothing protection and avoid of these items can melt it, causing a severe • ALWAYS unplug the main pump when touching your eyes while working with battery burn. installing or servicing the backup pump or acid or working near the battery. • ALWAYS remove the charger from the electrical float switch to avoid electric shock. • If battery acid contacts skin or clothing, wash outlet before connecting or disconnecting the • DO NOT expose the control unit to rain or immediately with soap and water. If acid battery cables. Check the polarity of the snow. enters eye, immediately flood eye with battery posts. The POSITIVE (+) battery post • DO NOT pull the cord when disconnecting the running cold water for at least 15 minutes and usually has a larger diameter than the control unit. Pull the plug. get prompt medical attention. NEGATIVE (-) post. Page 1 Introduction Control Unit The Basement Watchdog Special backup sump pump system is battery-operated. It is designed as an emergency backup system to support your main AC sump pump, and it will automatically begin pumping any time the float switch is Battery Battery Wires activated by rising water. Should any Box malfunction or emergency occur that involves the sump pump, the battery, or the AC power, Fluid Sensor the Basement Watchdog system will sound an alarm. A light on the display panel of the control unit will indicate the cause of the alarm and the corrective action. For added reliability, the float switch has, not one, but two floats. Should one float fail to operate, the second float automatically activates the pump. The Basement Watchdog Special Sump Pump System includes: • A control unit with a dual float switch, a battery fluid level sensor, battery cables, and a 20 amp fuse • A pump with a 1½” PVC pipe adapter Float Pump • A plastic wire tie for mounting the float switch Switch Pipe Cap • A battery box Replacement Part Numbers • A battery charger Wire Tie Charger Adapter Pump . .1011002 • A battery cap with a hole to accommodate the Float switch assembly . .1020009 fluid sensor Fluid sensor assembly . .1014001 Pipe adapter . .1120002 You will also need to supply: Use of a Basement Charger . .1015001 • A Basement Watchdog 7.5 Hour Standby Watchdog Klunkless Battery box . .1113003 Battery Check Valve™ will Battery cap with hole . .1125000 DO NOT use an automotive battery with this provide quieter system operation. (See Call 800-991-0466, option #3 to order parts. DO NOT use a maintenance-free or sealed page 18 for more battery with this system information.) DO NOT use a Basement Watchdog Emergency System Specifications battery with this system. It will not run the Power supply requirements . .115 volts AC pump as long as the 7.5 hour battery Pumping capacity . .2500 GPH @ 0’ • 1½” rigid PVC pipe and fittings Pumping capacity . .1730 GPH @ 10' 5 • PVC primer and cement For narrow sump pits you will need some Pump dimensions w/elbow . .7 ⁄8” H x 9”W • A union with hose clamps or a “Y” connector additional parts: Pump housing & strainer . .non-corrosive, and two (2) check valves, depending on the • An “L” bracket at least six (6) inches long will not rust installation method you use (preferably one that will not rust) Pump . .can run dry for short periods of time; • A surge protector (recommended) • Two (2) stainless steel hose clamps can be used in sumps with water softener • Six (6) quarts of 1.265 specific gravity battery • One (1) stainless steel screw (#8-32 x 3/4”), a Float switch . .independent, can be acid matching washer & nut set at any level Page 2 Pump & Pipe NORMAL SUMP PIT Installation Instructions INSTALLATIONS FLOOR FLOOR JOIST There are two basic methods that can be used to JOIST install the pump, a direct discharge to the SLOPE PIPE outside of the building, or a connection to an DOWN existing discharge pipe. The same two options apply in very narrow sump pits where the backup RIGID RIGID pump must be mounted above the main pump.