Approaches to Energy Efficient Building Development – Studying Under Chinese Contexts

Total Page:16

File Type:pdf, Size:1020Kb

Approaches to Energy Efficient Building Development – Studying Under Chinese Contexts Approaches to Energy Efficient Building Development – Studying under Chinese Contexts Zhenhong Gu Licentiate thesis Industrial Ecology School of Industrial Engineering and Management Royal Institute of Technology Stockholm, October 2007 Title: Approaches to Energy Efficient Building Development – Studying under Chinese Contexts Author: Zhenhong Gu Registration: ISSN 1402 - 7615 TRITA-IM 2007:23 Published by: Royal Institute of Technology School of Industrial Engineering and Management Division of Industrial Ecology SE – 100 44 STOCKHOLM, SWEDEN Phone: (+46) 8 790 87 93 (distribution) (+46) 8 790 87 61 (author) Fax: (+46) 8 790 50 34 E-mail:[email protected] Print by: Universitetsservice US AB, Stockholm, Sweden, 2007 Abstract This thesis presents a general description of approaches to energy efficient building development under Chinese contexts. The purpose of the work is to discuss how Chinese building development can be approved from an energy saving perspective. Building development is a complicated process that relates to many stakeholders’ interests. The developed countries have studied in this field extensively for several decades. Generally, the approaches to energy saving can be set at three levels: administration, construction industry and architectural design. More new strict codes for energy efficient buildings are being issued for enforcement. At the same time, many research institutes have developed Building Environmental Assessment (BEA) methods, where energy efficiency is an important factor in the models. Various technical solutions for energy efficiency are developed as well. The administrative approaches are not the main objective discussed in the thesis, though the importance of them is undeniable. BEA systems are not only assessment methods, but also market- based stimulating approaches for sustainability of construction market. Technical methods have been developed for a long period. Passive House and Low Exergy (LowEx) Systems are two representative examples in European countries. All of these approaches are relatively unfamiliar to Chinese architects and developers, let alone their effect and applicability. The thesis tries to analyse this situation and their applicability within Chinese context. In China to a certain project, the importance of technical issues is relatively recognized. However, a few successful individual cases in technique can not change the reality that most of new building development has failed in energy efficiency in China. This is a serious situation when China is in an enormous expansion phase in building new houses. The thesis tries to discuss the reasons for this phenomenon. One reason could be that the stakeholders in the developing process are not aware of the importance of collaboration which is the only method to get “Both Win” according to Game theory. The thesis discusses a paradigm to replace two traditional linear paradigms in building developing process. Architects should act as coordinators of different stakeholders rather than technical supporters. The thesis tries to discuss the propositional route of developing energy efficient buildings. Technical approaches are basic research, which presents the concepts that have been proved realizable; BEA encourages developers to develop more energy efficient buildings for economic benefit, which will make good demonstrations for whole market; national laws and policies are final approaches, which ensure that every project will have good performance of energy efficiency. When the old standardization and legislation are finished, a new cycle will begin with more advanced techniques. China government has started the progress to enhance energy efficiency. However, this process will be tough and slow. The thesis discusses Chinese special conditions and the problems that cry out for solution in the future. Keywords: Energy efficiency, China, Passive House, Low Exergy system, Built Environmental Assessment, LCA, Swedish housing, Hammarby Sjöstad, Eco-village, Game theory, System theory, Soft Systems Methodology i Acknowledgements This research results from the cooperation between Industrial Ecology, Royal Institute of Technology (KTH), Sweden, and Architectural School, Southeast University (SEU), China. As a part of the cooperation, some Chinese young teachers came to Sweden to attend in advanced courses. In autumn 2004, as one of these students, I came to KTH to begin the doctoral program under the direction of my supervisor, Prof. Ronald Wennersten, the head of Industrial Ecology. Prof. Ronald Wennersten realized the contrast between advanced technologies and unsatisfactory developing status of building development, which shows the importance of social aspects. Without appropriate mechanisms, technologies are only theoretical but unfeasible. He had worked in the field of mechanisms of sustainable development, including environmental assessment, risk management, and water management of communities, for a long time. I have been fortunate enough to work with him. His intelligent and acute comments have inspired me. I am grateful for his important guidance and help. Dr. Getachew Assefa and Prof. Dick Urban Vestbro at School of Architecture and Built Environment, KTH helped me to improve the papers and gave me valuable guidance. Ester Galli has helped me to perfect the structure of thesis and language corrections. I appreciate your collaboration. My sincere gratitude goes to all my colleagues at Industrial Ecology, KTH and Architectural School, SEU, for their valuable comments, support and friendship. Prof. Dongqing Han, Prof. Wei Dong and Prof. Tong Zhang introduced and guided me to study at KTH. Karin Orve, the Education Administrator of the Industrial Ecology at KTH, has untiringly provided me warm assistance. Kosta Wallin has kept my most important working tool, the computer and printer, in order. Xingqiang Song, Xiangjun Wang and other colleagues present many important comments on my work. I am indebted to you all. My special gratitude goes to Yingfang He at International Office of KTH. During the period of my studying at Sweden, her warm help gave me homely feeling in a foreign land. I am grateful to you. My parents and wife always are my strong backers. Thank you for your patience and understanding. Finally I want to thank all of my collaborators and friends who have been supportive and helpful during my work. Thank you all. Stockholm, October 2007 Zhenhong Gu ii Outline and list of appended papers The outline of this thesis is based on four papers, which constitutes a flow of how this research has developed. The three first papers form a base for the fourth and final article where a preliminary study on the approaches to energy efficient building development. Paper one describes the sustainability assessment of residential areas and sustainable building design within Chinese context. Paper two compares two methods of energy efficient house and the implemental discussion in China. Paper three carry out a sensitivity analysis of most widely used building environmental assessment methods. These two papers describe the technical methods of energy efficient buildings. Paper four compares two housing paradigms in Sweden and presents the developing strategies to energy efficient housing development within Chinese context combined with game theory and Swedish experiences. I. Gu, ZH., Wang, XJ., Wennersten, R., and Dong, W. (2005) Sustainability Assessment of Residential Areas and Sustainable Building Design in China, the 3rd international conference of the International Society for Industrial Ecology. I described the situation of current sustainability assessment tools and sustainable buildings, presented potential ideas to be developed in China. I wrote parts of the paper. II. Gu, ZH., Wennersten, R. (2006) Comparison of Two Methods of Energy Efficient Houses: Implemental Discussion in China, Conference Proceedings, 10th international Passive House conference. I carried out the literature survey, the comparison of two methods of energy efficient houses and wrote the paper. III. Gu, ZH., Wennersten, R., Assefa, G. (2006) Analysis of the most widely used Building Environmental Assessment methods, Environmental Sciences September 2006; 3(3): pp. 175 – 192. I carried out the literature survey, the comparison of the BEA methods, made the diagrams, and wrote the paper. IV. Gu, ZH., Wennersten, R. (2006) A study about Chinese developing strategies to energy efficient housing development in architect’s perspective, combined with Swedish experiences and Game Theory, Submitted to Journal of Housing and the Built Environment. I presented the strategies for energy efficient building development based on Swedish case studies and wrote the paper. iii List of abbreviations BEA Built Environmental Assessment BREEAM BRE Environmental Assessment Method HVAC Heating, Ventilation, and Air Conditioning LCA Life Cycle Assessment LEED Leadership in Energy and Environmental Design LEH Low-energy House LowEx Low Exergy NABERS National Australian Built Environment Rating System RH Relative Humidity SSM Soft Systems Methodology USGBC U.S. Green Building Council iv Table of contents Abstract ................................................................................................................................................ i Acknowledgements ............................................................................................................................. ii Outline and list of appended papers ...................................................................................................iii
Recommended publications
  • What Makes an Eco-Town?
    What makes an eco-town? A report from BioRegional and CABE inspired by the eco-towns challenge panel Written and published in 2008 by the BioRegional Development Group and the Commission for Architecture and the Built Environment (CABE). Graphic design: Draught Associates Front cover image: Great Bow Yard housing scheme © Design for homes/ Richard Mullane All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, copied or transmitted without the prior written consent of the publishers except that the material may be photocopied for non-commercial purposes without permission from the publishers. This document is available in alternative formats on request from the publishers. BioRegional is an entrepreneurial charity CABE is the government’s advisor on architecture, which invents and delivers practical solutions urban design and public space. As a public body, we for sustainability. We develop sustainable encourage policymakers to create places that work products, services and production systems for people. We help local planners apply national – and set up new enterprises and companies design policy and advise developers and architects, to deliver them; initiate and guide the persuading them to put people’s needs first. We show development of sustainable communities; public sector clients how to commission projects that and seek to replicate our approach through meet the needs of their users. And we seek to inspire consultancy, communications and training. the public to demand more from their buildings and Our aim is to lead the way to sustainable living spaces. Advising, influencing and inspiring, we work to – through practical demonstration. create well designed, welcoming places.
    [Show full text]
  • Thinking Wood As a Material of Choice Costs Less, Delivers More
    CONTINUING EDUCATION THINKING WOOD AS A MATERIAL OF CHOICE COSTS LESS, DELIVERS MORE Presented by: LEARNING OBJECTIVES After reading this article you will be able to: 1. Compare the material, project and environmental costs of wood to other building materials. 2. Explain innovative wood technologies and how they are contributing to a wide range of sustainable designs. 3. Discuss the environmental impact of wood through- out its life cycle, including its renewability, certifi- cation options, impacts on energy efficiency, low carbon footprint, and end-of-life recycling and reuse. 4. Examine research and examples demonstrating the positive impact of exposed wood on a building’s occupants. CONTINUING EDUCATION AIA CREDIT: 1 LU/HSW GBCI CREDIT: 1 CE Hour AIA COURSE NUMBER: ARmay2015.4 GBCI COURSE NUMBER: 920003245 Use the learning objectives above to focus your study as you read this article. Visit http://go.hw.net/AR515Course4 to read more and complete the quiz for credit. Cathedral of Christ the Light; Oakland, California; Design architect: Skidmore, Owings & Merrill. Photo by Timothy Hursley Designers today are finding new possibilities reimagined use; and a unique human-nature which minimizes construction delays and keeps in one of the oldest building materials on connection that has always been intuitive, but is labor costs competitive. Wood’s adaptability earth. Wood has always been valued for its now being documented in research. and ease of use also translate into faster con- beauty, abundance and practicality, but many struction schedules, while a smaller foundation of wood’s inherent characteristics are rising COST CONSCIOUS may be needed because of its light weight.
    [Show full text]
  • Case Studies
    Section 4: Case Studies Section 4: Case Studies 18 case studies have been identified in the East Midlands – information on the following are set out below: Sustainable housing in the East Midlands - 119 Section 4: Case Studies Albert Hall Memorial Housing, Coalville Location Coalville, Leicestershire Type of Area Suburban Tenure Social housing rental Built Form Detached bungalow Contact Name East Midlands Housing Association Phone / e-mail (01530) 839091 Summary The development consists of seven dwellings incorporating elements of passive solar design, high levels of insulation and mechanical heat recovery ventilation. It was designed and built by the East Midlands Housing Association for older clients. Extensive monitoring and analysis was carried out by the Energy Technology Support Unit (ETSU) as part of the project, and much of the information presented here draws on this report. The project demonstrates how more attention and research at the design stage can enhance the benefits that may be derived from such energy saving features. It also shows how the perspectives of success or failure of a design differ between building professionals and residents. Project Objectives To create a high-quality flagship sheltered housing development for older people that is highly energy efficient and incorporates the principles of passive solar design. History of Concept The development, which was constructed in 1990, consists of seven dwellings (three two bedroom and four one bedroom bungalows) and is a memorial to a former member of the housing association, Albert Hall. The association wanted an energy efficient scheme that used electricity as its main heat source. The energy consultants decided on a highly insulated design with controlled ventilation that would meet the regional electricity company’s Civic Shield 2000 standard.
    [Show full text]
  • BR08 Assessor Listing NEW.Qxd 29/05/2008 12:20 Page 23
    BR08 assessor listing NEW.qxd 29/05/2008 12:20 Page 23 June 2008 Assessor listing | BREEAM 23 NEED AN ASSESSOR? A complete listing of certified assessors across the UK Key: Code: Code for Sustainable Homes EcoH: EcoHomes MR: Multi-Residential Type of BREEAM scheme Company and phone number Bespoke Courts Code EcoH Ind MR Offices Retail Schools Prisons 2020 Liverpool 0151 237 2020 ●● 3 Planets 01332 416158 ● ●●●●●●● 3Dee 01202 484248 ● 3DReid 020 7297 5600 ●●● A2 Housing Group 07967 813669 ●● AA Energy Consultants 07884 261631 ● Aardvark EM 01984 624989 ● ab consulting engineers 0121 323 2332 ●● Abacus 01751 460014 ●● Abbey Consultants (Southern) 01923 274427 ●● Abdale Associates (Tring) 01442 382568 ●● ● Active Energy 07793 820897 ● Adams Integra 01243 771304 ●● Adrian Pragnell 07870 838259 ●● Advance Housing and Support Group 01993 772885 ● Aegis Environment 0871 242 5812 ● AEW Architects and Designers 0161 214 4370 ●● AHP (Architects and Surveyors) 020 8313 1023 ●● Alan Tate Consultancy 01274-583408 ●● Allen Tod Architecture 0113 244 9973 ● Ambient Energy & Environment 0114 266 5704 ● ●●●●●●● AmicusHorizon Group 020 8726 8600 ● An Norvys 01767 677577 ● Andre Gardner Associates 020 8599 4018 ●● Andreassen Associates 01344 626997 ●● Andrew Leighton Associates 01633 883030 ●● Aragon Housing Association 01525 840505 ● Architect Holling 01463 223710 ● Architects Design Partnership 0207 287 3224 ●●● Architecture Collective 00 353 56 777 0480 ● Architecture PLB 01962 842200 ●● Ark Consultancy 0121 515 3831 ●● Ark Design & Architecture 01942
    [Show full text]
  • Passive House Cepheus
    PASSIVE HOUSE CEPHEUS • The term passive house (Passivhaus in German) refers to the rigorous, voluntary, Passivhaus standard for energy efficiency in buildings. It results in ultra-low energy buildings that require little energy for space heating or cooling. A similar standard, MINERGIE-P, is used in Switzerland. The standard is not confined only to residential properties; several office buildings, schools, kindergartens and a supermarket have also been constructed to the standard. Passive design is not the attachment or supplement of architectural design, but an integrated design process with the architectural design. Although it is mostly applied to new buildings, it has also been used for refurbishments. Thermogram of a Passive house Explain the difference CEPHEUS - Passive Houses in Europe.mht • Passive Houses require superior design and components with respect to: • insulation • design without thermal brigdes • air tightness • ventilation with heat recovery • comfortwindows und • innovative heating technology • To realise an optimal interaction of all components, an energy balance of the building has to be worked out. And step by step any new design may be improved to meat Passive House sta HOW? WALL FLOOR WALL WINDOW Space heating requirement • By achieving the Passivhaus standards, qualified buildings are able to dispense with conventional heating systems. While this is an underlying objective of the Passivhaus standard, some type of heating will still be required and most Passivhaus buildings do include a system to provide supplemental space heating. This is normally distributed through the low- volume heat recovery ventilation system that is required to maintain air quality, rather than by a conventional hydronic or high-volume forced-air heating system, as described in the space heating section below.
    [Show full text]
  • Green Building Certification System Review – Appendices
    PNNL-20966 Prepared for the U.S. General Services Administration under the U.S. Department of Energy Contract DE-AC05-76RL01830 Green Building Certification System Review – Appendices N Wang KM Fowler RS Sullivan March 2012 DISCLAIMER This Report was prepared as an account of work sponsored by the agency of the United States Government. Neither the United States Government nor any agency thereof, nor Battelle Memorial Institute, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORY operated by BATTELLE for the UNITED STATES DEPARTMENT OF ENERGY under Contract DE-AC05-76RL01830 Printed in the United States of America Appendix Table of Contents Appendix A: EISA Sections 433 & 436 ...................................................................................................... A‐1 Appendix B: High Performance Sustainable
    [Show full text]
  • Glasgow's Affordable Housing Supply Programme
    Front cover: Commonwealth Games Athletes’ Village 2 GLASGOW’S AFFORDABLE HOUSING SUPPLY PROGRAMME QUALITY, INNOVATION & SUSTAINABILITY 13 Performance Review 2013/14 Table 13 – SAP Ratings Featured Projects – 2014 Commonwealth Games Athletes’ Village CONTENTS PAGE NO Centurian Way INTRODUCTION 2 Holmlea Court HOUSING UNITS 4 Glasgow’s AHSP Project Awards Table 1 – Unit Approvals by Housing Investment Area POST COMPLETION REVIEWS 24 Table 2 – New Build Unit Approvals by Tenure TRANSFORMATIONAL REGENERATION AREAS Table 3 – Unit Approvals by Grant Type (TRAs) 25 Table 4 – Unit Targets and Approvals by Housing Maryhill Investment Area – Wheelchair Housing Gallowgate Table 5 – Unit Targets and Laurieston Approvals by Housing Investment Area North Toryglen – Larger Family Homes Pollokshaws Table 6 – Unit Targets and Completions by Grant Type Sighthill APPENDIX 1A – MAP OF UNIT APPROVALS 30 EXPENDITURE 8 APPENDIX 1B – MAP OF UNIT COMPLETIONS 31 Table 7 – Expenditure by Housing Investment Area Table 8 – Expenditure by Grant Type APPENDIX 2 –FUNDING BY HOUSING 32 Medical Adaptations (Stage 3) ASSOCIATION DEVELOPMENT COSTS, RENTS & GRANT 10 Table 1 – Housing Association GPTs and Out-turns LEVELS – Mainstream Programme Table 2 – Housing Association GPTs and Out-turns Table 9 – Development and Works Costs – LSVT Programme Table 10 – Housing Association Rents in Tender Table 3 – Housing Association GPTs and Out-turns Approvals - Reprovisioning Programme Table 11 – Grant Levels for Tender Approvals Table 4 – National and Regional Housing Associations included in Tables 1, 2 and 3 Table 12 – Grant Levels v Grant Subsidy Benchmark FOREWORD BY LIZ CAMERON, EXECUTIVE MEMBER FOR BUSINESS & THE ECONOMY As the Strategic Housing Authority for our city, Glasgow City Council’s vision is that people will want to live in Glasgow, and that they will have a choice of affordable, high-quality homes across a range of tenures.
    [Show full text]
  • GREEN Vs. SUSTAINABLE: ANALYZING and EXPANDING LEED (LEADERSHIP in ENERGY and ENVIRONMENTAL DESIGN)
    Copyright Warning & Restrictions The copyright law of the United States (Title 17, United States Code) governs the making of photocopies or other reproductions of copyrighted material. Under certain conditions specified in the law, libraries and archives are authorized to furnish a photocopy or other reproduction. One of these specified conditions is that the photocopy or reproduction is not to be “used for any purpose other than private study, scholarship, or research.” If a, user makes a request for, or later uses, a photocopy or reproduction for purposes in excess of “fair use” that user may be liable for copyright infringement, This institution reserves the right to refuse to accept a copying order if, in its judgment, fulfillment of the order would involve violation of copyright law. Please Note: The author retains the copyright while the New Jersey Institute of Technology reserves the right to distribute this thesis or dissertation Printing note: If you do not wish to print this page, then select “Pages from: first page # to: last page #” on the print dialog screen The Van Houten library has removed some of the personal information and all signatures from the approval page and biographical sketches of theses and dissertations in order to protect the identity of NJIT graduates and faculty. ABSTRACT GREEN vs. SUSTAINABLE: ANALYZING AND EXPANDING LEED (LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN) by Sonay Aykan This dissertation investigates the possibility of including new socio-economic indicators in green building rating systems in order to promote innovative practices in the building planning, design, construction and operations by introducing a broader definition of sustainability in the building industry.
    [Show full text]
  • VINCI PLC VINCI Construction UK Limited Astral House Imperial Way Watford Hertfordshire, WD24 4WW T: 01923 233433 VINCI PLC Annual Report 2008
    Head Office VINCI PLC VINCI Construction UK Limited Astral House Imperial Way Watford Hertfordshire, WD24 4WW T: 01923 233433 VINCI PLC Annual Report 2008 VINCI PLC is part of VINCI, the world’s leading concessions and construction group. www.vinci.plc.uk VINCI PLC Annual Report 2008 17382 VinciPLC R&A 2008- Cover 1 30/06/2009 09:00 Contents Cover image: Warwick Digital Laboratory, Warwickshire. This page: Newfi eld and Talbot School, Sheffi eld. 17382 VinciPLC R&A 2008- Cover 2 30/06/2009 09:00 “...providesOur mission VINCI is PLCto be with the preferreda national construction, platform to performfacilities all facets and associated of construction services and partner facilities for our clients and to be the benchmark against which services from the smallest to the largest project.” our competitors are measured. Report Operating and Financial Review Company Information 2 Chief Executive’s Report 4 During 2008, the UK economy enteredCorporate into Responsibility more diffi cult circumstances with a noticeable 26 slow down in construction activity,Enhanced particularly Business in Reviewthe private sector where we had fewer 30 opportunities. Turnover in certain sectorsDirectors’ of Report the Group fell by comparison with 2007, with a 32 Statement of Directors’ Responsibilities 34 reduction in output in Norwest Holst Building Division and John Jones. In regional building, Independent Auditors’ Report 36 turnover increased as a result of the impact of the acquisition of Stradform and Gordon Durham. Accounts The most important event in the year, however,Consolidated was Incomethe acquisition Statement Acquisitions and Disposals 38 in September of Taylor Woodrow ConstructionStatements Limited.
    [Show full text]
  • The Affordable Warmth Strategy for Northampton Borough Council 2011 - 2014
    Growing Together Neighbourhood Plan - Evidence Document 2: Affordable Warmth Strategy 2011-2014 Affordable Warmth Strategy 2011 – 2013 - 1 - The Affordable Warmth Strategy for Northampton Borough Council 2011 - 2014 Affordable Warmth Strategy 2011 – 2013 - 2 - Contents Executive Summary Foreword What is affordable warmth Affordable Warmth in Northampton Where are we now? What information have we used to inform this strategy development? Strategy Key Priorities and Actions Appendices References Glossary Affordable Warmth Strategy 2011 – 2013 - 3 - Executive Summary This strategy describes our approach to helping households in fuel poverty achieve affordable warmth. A household is considered to be in fuel poverty if it needs to spend more than 10% of its income on fuel to maintain an adequate level of warmth. The links between ill health, poor housing and fuel poverty are well documented.1 The Bank of England commented in May 2011 that gas prices could rise by 15% later this year, and electricity by 10%. Centrica, the owner of British Gas, has predicted that the wholesale cost of gas could go up by 25% this winter (2011), confirming that the Bank of England's predictions may well be realised. Britain's big six energy suppliers have increased their domestic gas and electricity prices in 2011 by 5.4pc or £65, with the typical annual household energy bill shooting up to an average of £1,250 as a result.2 Energyhelpline.com suggest that England’s average household energy bill for last winter rose to £453 per quarter.3 They attribute this in part to the extreme cold temperatures. This has meant that, nationally, more than a million households have been pushed into fuel poverty over the last 12 months.
    [Show full text]
  • Lancaster District Local Housing Needs and Demand Survey ‐ 2011
    LANCASTER DISTRICT LOCAL HOUSING NEEDS AND DEMAND SURVEY LOCAL PLAN CONSULTATION FINAL REPORT (SUMMER 2012) Lancaster District Local Housing Needs and Demand Survey ‐ 2011 CONTENTS 1 EXECUTIVE SUMMARY............................................................................................................................9 1.1 INTRODUCTION............................................................................................................................................9 1.2 THE HOUSING STOCK....................................................................................................................................9 1.3 THE ECONOMIC CLIMATE.............................................................................................................................10 1.4 THE FUTURE POPULATION ...........................................................................................................................11 1.5 THE HOUSING MARKET ...............................................................................................................................12 1.6 AFFORDABILITY AND ENTRY TO MARKET HOUSING ...........................................................................................12 1.7 MIGRATION AND MOVING HOUSEHOLDS........................................................................................................13 1.8 HOUSEHOLDS WITH SUPPORT NEEDS .............................................................................................................13 1.9 OLDER PERSONS HOUSEHOLDS .....................................................................................................................14
    [Show full text]
  • TANZANIA LOCAL SUPPLIERS and SERVICE PROVIDERS DATABASE Country of Company Business Additional No
    TANZANIA LOCAL SUPPLIERS AND SERVICE PROVIDERS DATABASE Country of Company Business Additional No. REF. NO. Legal Name Registratio Physical Address Type Category Information n A: Manufacturing P.O. Box 8702, DAR ES Advent Limited SALAAM 255753097056; Metal, Alminium, 1 LSSP-2019-04-05 Construction Liability Fabrication TANZANIA 255716505058; and Glass Works; Limited Company babuu@adventconstructions .com Mwakalinga Rd, Engineering Manufacturer of HI- Chang'ombe, Temeke, Limited (Manufacture Tensile Steel Re- P.O. Box 10392, Dar es Kamal Steels 2 LSSP-2019-04-06 Liability of Bars (Grade TBS TANZANIA Salaam. Ltd Company Reinforcement &BS500) and 222862975/sales@kamalste Steel) Structural Steel) el.co.tz/satyam.gupta@kam al-group.co.tz Ubungo Industrial Estate, Manufacture of Plot No. 4, Morogoro Road, Limited Tanzania Steel Engineering large diameter Box 3 LSSP-2019-04-07 Liability TANZANIA Pipes Ltd Services steel pipes and 5476,+255222450457/+255 Company fittings 22784987630/+2552278498 7631 [email protected] Country of Company Business Additional No. REF. NO. Legal Name Registratio Physical Address Type Category Information n Plot 112, Mbozi Road, Temeke, P.O. Box 19956, Dar es Salaam. Manufacture of Manufacture of 222199824/0767390079/078 Limited HDPE & UPVC HDPE & UPVC 4999786/ Email: 4 LSSP-2019-04-08 Plasco Limited Liability TANZANIA pipes and pipes and related [email protected] , Company related fittings fittings [email protected], Tel: +255-22-2199 820/ 821/ 822/ 823 Fabrication of new trailers, fuel tankers and low Longido
    [Show full text]