Premium Downtown Data Centre: Stand-Alone or Natural Extension to 151 Front St. TOR 2: 905 King Street West

The 905 King Street facility is a state-of-the-art data centre designed to Tier 3 standards for concurrent maintainability for space, power, mechanical systems Tour the Data Centre: 905 King Street West and security. The data centre can be utilized as a stand-alone, diverse bypass Toronto, M6K 3G9 facility to the 151 data centre, or can be leveraged as a natural extension with the diverse fibre ring connecting the two facilities. By linking the To schedule, contact: two downtown data centres, Cologix customers have the benefits of both with [email protected] or unsurpassed levels of security, reliability and connectivity. +1.855.497.2537

The Top Connectivity Provider in Canada Through direct access to the Meet-Me-Room (MMR) at 151 Front Street, 905 King Street Quick Facts: has access to 140+ unique networks via a low latency, diverse . The 905 King Street  Network neutral access to 8+ unique data centre offers diverse building fibre entrances and riser facilities, as well as carriers on-site plus 140+ networks at 151 interconnectivity with local Cologix clients and other building tenants. Front Street West via diverse fibre ring

Technology Forward  Offers the connectivity benefits of 151 Cologix designed the state-of-the-art data centre with full optimization of the base Front Street with additional ability to building chilled water cooling, utility power and emergency generator power systems to access network routes on-site that ensure a reliable and redundant setup. The multiple backup generators enable power bypass 151 Front Street to long-haul redundancy configurations that meet customer-specific needs, with separate generators networks supporting the cooling infrastructure. The uniquely efficient N+1 design features  Designed to Tier III standards for technology-forward solutions including hot aisle containment systems with in-row concurrent maintainability of power & cooling and modular power distribution systems to provide rapid power installs and mechanical systems flexibility on power densities within pods.  Power redundancy configurations ranging from UPS + backup generator & Certified & Secure A+B UPS + generator back up, to full 2N The 905 King Street building lobby is manned 24/7 by security guards (the data centre architecture suite will soon have round-the-clock guards as well), in addition to dual interlocking  SSAE 16 SOC 1 audited doors, a tailgate-proof mantrap, keycard access, biometric, and closed-circuit TV (CCTV)  Customer tech workspace, conference systems. The facility is designed to meet SSAE 16 SOC1 compliance, with support to gain room & lounge area PCI compliance on an individual basis.

Dynamic Customer Support As a differentiated local service model, all customers have direct and 24/7 access to seasoned local engineers and support teams, in addition to a web-based portal for online technical support ticket submissions. Cologix technical support staff also leverage the Cologix Command data centre infrastructure management (DCIM) system.

Why Cologix Toronto? Customers prefer Cologix Toronto because of the prime downtown locations, as well as the network reach, offering almost all providers available in the region. Clients also find the data centre’s reliability, upgrades and redundancies are augmented by the ease of doing business with Cologix.

20 Network Neutral Data Centres Throughout North America Columbus - Dallas - Jacksonville - Lakeland - Minneapolis - Montreal - Toronto - Vancouver

[email protected] | 1.855.497.2537 | www.cologix.com

SITE SPECIFICATIONS: TOR 2: 905 King Street West

Site Information Connectivity

Toronto 2 Space: 20,000 SQF Yes, MMR within Cologix facility with Meet-Me-Room (MMR): Total Toronto Space: 45,000 SQF direct access to building’s MMR Custom cabinets & cages including 8 unique network provider PoPs on Space Configurations: deep 42U cabinets (78” H x 24” W x Number of Networks: site, with access to 140+ unique carriers 48” D) via diverse path to 151 Front St. APC hot aisle containment pods Network Neutral: Yes Diverse building fibre entrance & riser Pod Configurations: (premium dedicated pod options for Fibre Entrance: 10+ cabinets) facilities Yes, in suite & to other tenants with Floor Type: 14” anti-static raised floor Fibre Cross Connects: access to 151 Front Street MMR Freight Elevator: 1 service elevator, 1,810 lbs Copper Cross Connects: Yes, in suite Latency to 151 Front 0.016 millisecond network latency Site Structure Street West: Passive waves & lit connections to 151 Metro Connect: Year Built: 1985 Front Street West Renovated: Ongoing Communications: 2 diverse communication risers Number of Floors: 7 floors Structure Type: Concrete & steel Power Exterior Type: Concrete Uninterruptible Power Seismic Rating: UBC Seismic Zone O Power efficient APC UPSs (N+1) Supply (UPS): In Flood Plain: No 150 with SQF (higher density Ceiling Clearance: 13’ 11” Load Design: configurations available in excess of 8 kW/cabinet) Customizable power configurations up Configurations: Security to 2N UPS & generator

Automatic Transfer SSAE 16 Compliant: Yes Yes, diverse Switch (ATS): Closed-Circuit TV: Yes Valve-regulated lead-acid battery Battery Type: Customized Security: Yes, for dedicated pods or cages (VRLA) On-site Guards: Yes, 24/7 in lobby Battery Redundancy: Minimum N+1 Access: Biometric & S2 keycard access Battery Monitoring: Canara battery monitoring Yes, 2x dual interlocking doors & Man Traps: Backup Generators: Yes, multiple generators tailgate-proof mantrap Fuel Run-Time: Diesel, minimum 24-hours at full load Remotely Monitored: Yes Fire Protection

Cross-zoned Very Early Smoke Site Utility Fire Protection: Detection Apparatus (VESDA) 13.8 kV primary & standby redundant Fire Suppression: Dual interlocked pre-action Electric: feeders Remotely Monitored: Yes Utility Provider: Toronto Hydro Redundant Power Feeds: Yes, A+B Environmental Controls Power from Substation: 4 MVA x 2 feeders Chilled water loop connected to Water: Cooling System: Chilled water building-owned chillers Cooling Capacity: 2,320 tons (N+1) Cooling Type: APC in-row cooling solutions N+1 high performance chillers / N+1 Customer Support Redundant: cooling tower Remote Hands: Yes, 24/7 Humidification: Centralized ultrasonic +1.855.4IX.HELP (+1.855.449.4357), or Support: Remotely Monitored: Yes [email protected] +1.855.497.2537, or Sales: [email protected]

[email protected] | 1.855.497.2537 | www.cologix.com[Type text]